This chapter describes the commands that apply to semi-permanent virtual circuits (SPVCs). These commands allow you to add, delete, configure, display status, and specify statistics for SPVCs. The commands include the following areas:
•
Adding a connection
•
Modifying an existing connection
•
Deleting a connection
•
Display one connection or all connections
•
Downing and upping a connection in the course of maintenance or troubleshooting
Position-Dependent and Keyword-Driven Parameters
A command can include parameters that are keyword-driven or position-dependent.
For position-dependent parameters, you must type parameters in the order they appear in the syntax description or on-line help. To create a logical port, for example, the position-dependent syntax is:
addport <ifNum> <bay.line> <guaranteedRate> <maxrate> <sctID> <ifType> [vpi]
For a keyword-driven parameter, a keyword must precede the value. The keyword is preceded by a dash and followed by the parameter (-timeout <secs>, for example). The order you enter keyword-driven parameters does not matter—although any preceding or succeeding, position-dependent parameters must appear as they do in the command syntax description.
In the following syntax example, the command is to delete more than one connection at a time. The mandatory, position-dependent connection identifier consist of a logical port (ifNum) and the VPI and VCI of the first connection to delete. After the connection identifier, the line shows two optional, keyword-driven parameters. These keyword-driven parameters let you enter the number of connections to delete and specify verbose mode:
delcons <ifNum> <vpi> <vci> [-num <num. conns to del>] [-verbose < 1 | 0 >]
Command Entry
When you enter a command with the current version of the product, you must type all intended arguments before you press the Return key or Enter key.
If you press the Return key or Enter key with incorrect parameters or no parameters (if the command requires parameters), a message displays the syntax and parameter ranges. The returned message may also suggest what the problem is. For example, the message may warn of too few parameters. No error messages or warnings appear until you complete the command.
Identifying the AXSM Models
The model number of an AXSM identifies the line speed, line count, and number of bays (see Table 7-1.) Note that the number of lines applies to an individual back card, so the total number of lines supported by the front card equals the highest line number times the number of bays. The OC-48 card AXSM-1-2488 has the lowest number of lines—one. The highest number of lines exist on the AXSM-16-155 and AXSM-16-T3E3—16, as the name indicates.
The MGX 8850 node use the concept of a bay. The bay refers to the upper or lower location of a single-height card. (The switch has a double-height card cage, so a single-height back card necessarily occupies either an upper or lower position.)
The T3/E3, OC-3, and OC-12 versions of the AXSM can have two back cards, one in bay 1 (upper location of the back slot) and the second in bay 2 (lower slot). The MGX-AXSM-1-2488 (OC-48 AXSM) can have a back card in bay 1 only. For further descriptions and illustrations of the card sets, refer to Cisco MGX 8850 Hardware Installation, Rel 2.0.
Table 7-1 Valid Line Numbers and Number of Bays for AXSM Card Types
Front Card Speed Lines BaysAXSM-1-2488
OC-48
1
1
AXSM-4-622
OC-12
1-4
1-2
AXSM-16-155
OC-3
1-8
1-2
AXSM-16-T3E3
T3 or E3
1-8
1-2
Connection Capacities of the AXSM
The SVC and SPVC connection capacities for the front card, back card, and physical lines appear in Table 7-2 and Table 7-3. The capacity of a single AXSM card is greater than that of the node itself. Nevertheless, the tables provide these maximums when you plan the use of commands such as addrscprtn, addcon, and any other command where you may want to know the capacity of the configured item to support connections.
Table 7-2 Maximum Connections by Connection Type and Front Card
Front Card SVC SPVCAXSM-1-2488
128 K
64 K
AXSM-4-622
128 K
64 K
AXSM-16-155
128 K
64 K
AXSM-16-T3E3
128 K
64 K
Table 7-3 Maximum Connections on Back Cards and Lines
Card Type Back Card Maximum Physical Line MaximumOC-48c
128 K
64 K
OC-12c
64 K
32 K
OC-3c
64 K
32 K
T3
64 K
64 K
E3
64 K
64 K
Identifying Physical and Logical Elements
The Private Network-to-Network Interface (PNNI) control protocol and the AXSM use different formats to identify the same elements. This section describes the format of these elements in the PNNI and AXSM contexts and how they correspond to each other. When you configure or view items on the CLIs of different cards, you often need to specify it in PNNI as well as the AXSM. For example, when you configure a PNNI port on the CLI of the PXM-45, you also need to configure a port on the CLI of the AXSM. Furthermore, when you display a connection on the AXSM, you identify that same connection using a different format on the PXM-45 CLI. For specific examples of these parallel actions, see the Cisco MGX 8850 Software Configuration Guide, 2.0.
![]()
Note
Apart from the way PNNI and the lower levels of logic identify the same element, the issue of configuration sequence needs explanation. When you configure logical ports—as just one example—you must complete certain tasks on the AXSM CLI before and after related PNNI tasks. This manual describes prerequisites for certain commands, but refer to the Cisco MGX 8850 Software Configuration Guide, 2.0 for more details of this sequence.
AXSM Format
The AXSM items that you identify for addressing purposes are:
•
Slot
•
Bay
•
Line
•
Logical port
A logical port on an AXSM (and its CLI) always uses the label ifNum. For a UNI and NNI interface, a one-to-one correspondence exists between a logical port and a physical line. For virtual trunks, you can configure multiple ports for a line.
The maximum number of logical ports on an AXSM is 60 regardless of the AXSM model or the number of AXSM back cards. The range for ifNum is 1-60, also regardless of the whether the interface type is UNI. NNI, or VNNI.
PNNI Format
The elements of a port in the PNNI protocol are as follows:
•
A shelf number. The shelf is always 1 for the current product and so is usually omitted.
•
The slot number of the front card.
•
Subslot is the number of the bay where the back card resides. This number is 1 or 2. Because the default is 1, subslot is frequently omitted.
•
Port is the physical line.
•
Subport corresponds to the logical port (ifNum) on the AXSM.
The PNNI port identifier (portid) appears on only the PXM-45 CLI. Throughout this manual, portid refers the following format:
[shelf.]slot[:subslot].port[:subport]
The portid consists of a series of mandatory and optional elements. Note the period or colon associated with each optional element inside the square brackets. For the correspondence between a PNNI port and the AXSM elements, see Table 7-4.
Table 7-4 Mapping PNNI Port ID to AXSM Elements
PNNI port AXSMShelf
N/A
Slot
Slot
Subslot
Bay (for back cards
Port
Line
Subport
Logical port (ifNum)
An example of a PNNI port identifier is 1:2.1:3. This portid corresponds to slot 1, bay 2, line 1, and logical port 3 on an AXSM.
addcon
Add Connection
Adds a logical connection as an SPVC on a service module. An AXSM front card can support a maximum of 64K SPVCs. This command does not apply to SVCs.
Before Adding a Connection
Before you can add an SPVC, the following tasks must have been completed:
1.
The switch must have a network controller (see addcontroller description).
2.
A physical line must be active. Use the upln command or the CiscoView application.
3.
At least one logical port must exist on the active physical line. Use the addport command or the CiscoView application to create the port. If necessary, modify the port through cnfport.)
4.
At least one resource partition must exist on the logical port. Use addrscprtn or the CiscoView application. The resource partition should be associated with the controller added in step 1.
Adding a Connection
Adding a connection requires you first to provision a slave endpoint. Subsequently, you again execute addcon to provision a master endpoint. The master endpoint of the connection initiates the routing of the call and can be viewed as the "calling" party. The slave endpoint is the called endpoint. The following are characteristics of this master-slave arrangement:
•
When you add a slave endpoint, the system returns a slave endpoint identifier. You subsequently need to provide this slave endpoint identifier when specifying the master endpoint.
•
When you add the master endpoint, you must provide the slave endpoint identifier. (A copy and paste operation is probably more convenient than writing down the slave endpoint identifier.) After you finish adding the master endpoint, the switch starts routing the connection.
To modify the bandwidth parameters or configure usage parameter control (UPC), use cnfcon for all service types. In addition, ABR connections require more configurable parameters for implementing closed loop control. Use cnfabr to configure the ABR parameters.
Usage Guidelines
This section details about the application of certain addcon parameters. For example, a parameter may require you to specify it at both ends of a connection.
Traffic Parameters
Traffic parameters such as PCR, SCR, MBS are entered at both the master and slave endpoints for both the forward and reverse directions. Be sure that the value entered as "local" on one end is equal to the value entered as "remote" on the other end. For example, the lpcr on the slave endpoint should be same as the rpcr on the master endpoint and vice versa when you provision the connection at the other end. If you modify traffic parameters after creating an SPVC, you just modify them at both the master endpoint or the slave endpoint.
Traffic parameters such as CDV, CTD are entered at both the master and slave endpoints for both the forward and reverse directions. However, the values of these parameters entered at the slave end are ignored during call setup. Therefore, you can specify the lcdv, rcdv, lctd and rctd options at the master end only.
Routing Parameters
The routing parameter maxcost (specified using -mc option) need to be entered at the master endpoint only. The values of this parameters entered at the slave end is ignored and not considered during call setup.
Frame Discard
For the parameter frame discard (specified using -frame option), you need to enter it at only the master endpoint. This parameters has no significance at the slave end.
Local-Only Parameters
The parameters CDVT, stats enable, cc enable (specified using -cdvt, -stat, -cc) are significant only at the endpoint where you enter them. Therefore, they can be different at each end of the connection.
Card(s) on Which Command Executes
AXSM
Syntax
addcon
<ifNum>
<vpi>
<vci>
<service type>
<mastership>
[-slave <NSAP.vpi.vci>]
[-lpcr <local PCR >]
[-rpcr <remote PCR>]
[-lscr <local SCR>]
[-rscr <remote SCR>]
[-lmbs <local MBS>]
[-rmbs <remote MBS>]
[-cdvt <local CDVT>]
[-lcdv <local maxCDV>]
[-rcdv<remote maxCDV>]
[-lctd <local maxCTD>]
[-rctd <remote maxCTD>]
[-cc <OAM CC Cnfg>]
[-stat <Stats Cnfg>]
[-frame <frame discard>]
[-mc <maximum cost>]Syntax Description
For the applicable parameters, the "local" end is the point at which you are provisioning the connection.
Error Messages
The system displays error messages that can be printed out for the following reasons:
•
Some of the traffic management parameters apply to specific service types (rt-VBR, for example). If you type a parameter that does not apply to a selected traffic type, the connection is rejected.
•
Insufficient resources are available to accept the provisioning request.
•
The type of card does not support a certain feature.
•
The port cannot support SPVCs.
One of the following error messages appears if one of the preceding causes it true:
•
"Port does not support requested serviceType"
•
"lscr not allowed to exceed lpcr"
•
"rscr not allowed to exceed rpcr"
•
"lpcr must be defined for cbr serviceType"
•
"rpcr must be defined for cbr serviceType"
•
"lpcr and lscr must be defined for vbr serviceType"
•
"rpcr and rscr must be defined for vbr serviceType"
•
"lpcr must be defined for abr/ubr serviceType"
•
"rpcr must be defined for abr/ubr serviceType"
•
"Requested rcdv is too low"
•
"Requested rctd is too low"
•
"Requested max cell loss ratio (clr) is too high"
•
"Requested cell rate (lscr/lpcr) is too high"
•
"Requested cell rate (rscr/rpcr) is too high"
Related Commands
cnfcon, cnfabr, delcon, dspcon, dspcons, dncon, upcon
Attributes
Example
Add the slave end of a VCC on logical port 1 with VPI=10, VCI=40, CBR service type. Note that the system returns the slave end connection identifier in the hexadecimal NSAP format with the VPI.VCI at the end. When you add the master endpoint of the connection, type -slave followed by this connection identifier. You can do a copy and paste rather than typing the whole string.
pinnacle1.AXSM.a >addcon 1 10 40 1 sslave endpoint added successfullyslave endpoint id : 00000E1000001C008051B730FFFFFF010B180100.10.40clrpncon
Call Control Operations: Release Call
Releases a call.
Card(s) on Which Command Executes
PXM-45
Syntax
clrpncon <portid>{all | vpi}[vci]Syntax Description
portid
See PNNI Format.
all | vpi
Clear all or a specific VPI of the call.
Default = 0
vci
VCI of the call to clear. If no VCI is specified, this is a VP connection.
Related Commands
dsppncon, dspncons
Attributes
clrpnconstats
Call Control Operations: Clear Call Statistics
Clears existing call statistics for one port or all ports.
Card(s) on Which Command Executes
PXM-45
Syntax
clrpnconstats [ portid ]Syntax Description
portid
See PNNI Format.
Related Commands
dsppnconstats
Attributes
Examples
cnfabr
Configures the ABR-specific parameters for an existing SPVC. The connection must be of service type ABR (in the addcon command, service type=10).
Card(s) on Which Command Executes
AXSM
Syntax
cnfabr <ifNum> <vpi <vci>
[-icr <Initial cell rate>]
[-adtf <ACR decr. factor>]
[-rdf <Rate decr. factor>]
[-rif <Rate incr. factor>]
[-nrm <Cells per fwd RM>]
[-trm <Time between fwd RMs>]
[-cdf <cutoff decrease factor>]
[-frtt <fix round trip delay>]
[-tbe <transient buffer exposure>]
[-intvsvd <internal vsvd config>]
[-extvsvd <external vsvd config>]Syntax Description
Related Commands
addcon, cnfabrtparmdft, dspabrtparmdft
Attributes
cnfabrtparmdft
Config ABR Traffic Parameters Default
Configures the default ABR traffic parameter(s), used for SPVC, per port.
When a user requests an ABR connection, the controller adds the default ABR traffic parameters before the connection is committed. The user can change the ABR traffic parameters, per connection, using the cnfabr command available on the AXSM.
The default ABR traffic parameters are used in the SETUP message at the source when an SPVC for ABR service category is set up.Card(s) on Which Command Executes
PXM-45Syntax
Syntax
cnfabrtparmdft <portid>
[-rif RIF-value]
[-rdf RDF-value]
[-tbe TBE-value]
[-nrm NRM-value]
[-trm TRM-value]
[-adtf ADTF-value]
[-cdf CDF-value]
[-fsd FSD-value]Syntax Description
Related Commands
addcon, cnfabr, dspabrtparmdft
Attributes
cnfcdvtdft
Port Management: Configure Default CDVT
Configures the default CDVT to request UPC for cells received on the port. The new configuration applies to new incoming calls, not existing calls. This command can be used regardless of the state of the port.
Syntax
cnfcdvtdft <portid><service_category>[ microseconds ]Syntax Description
portid
See PNNI Format.
<service_category>
ATM 4.0 service category: cbr, rtvbr, nrtvbr, ubr, or abr.
•
cbr = constant bit rate
•
rtvbr = real time variable bit rate
•
nrtvbr = non-real time variable bit rate
•
ubr = unspecified bit rate
•
abr = available bit rate
micro seconds
Integer
Range: (0 through 2147483647)
Default value is set by the platform (250,000). If this parameter is not specified, the default is used/restored.
Related Commands
dspcdvtdft
Attributes
Examples
None unless errors occur.
cnfcon
Configure Connection
Modifies the connection bandwidth, policing, and routing parameters of an existing endpoint. For ABR-specific parameters, use the cnfabr command.
The command parameters consist of:
•
A logical port, VPI, and VCI to identify the connection
•
Bandwidth parameters for the local (master) end then the remote (slave) end
•
Policing parameters for the connection as a whole
Note that after you specify the mandatory connection identifier, all other parameters are optional.
Card(s) on Which the Command Executes
AXSM
Usage Guidelines
This section details about the application of certain addcon parameters. For example, a parameter may require you to specify it at both ends of a connection.
Traffic Parameters
Traffic parameters such as PCR, SCR, MBS are entered at both the master and slave endpoints for both the forward and reverse directions. Be sure that the value entered as "local" on one end is equal to the value entered as "remote" on the other end. For example, the lpcr on the slave endpoint should be same as the rpcr on the master endpoint and vice versa when you provision the connection at the other end. If you modify traffic parameters after creating an SPVC, you just modify them at both the master endpoint or the slave endpoint.
Traffic parameters such as CDV, CTD are entered at both the master and slave endpoints for both the forward and reverse directions. However, the values of these parameters entered at the slave end are ignored during call setup. Therefore, you can specify the lcdv, rcdv, lctd and rctd options at the master end only.
Routing Parameters
The routing parameter maxcost (specified using -mc option) need to be entered at the master endpoint only. The values of this parameters entered at the slave end is ignored and not considered during call setup.
Frame Discard
For the parameter frame discard (specified using -frame option), you need to enter it at only the master endpoint. This parameters has no significance at the slave end.
Local-Only Parameters
The parameters CDVT, stats enable, cc enable (specified using -cdvt, -stat, -cc) are significant only at the endpoint where you enter them. Therefore, they can be different at each end of the connection.
Syntax
cnfcon
<ifNum>
<vpi>
<vci>
<service type>
<mastership>
[-slave <NSAP.vpi.vci>]
[-lpcr <local PCR >]
[-rpcr <remote PCR>]
[-lscr <local SCR>]
[-rscr <remote SCR>]
[-lmbs <local MBS>]
[-rmbs <remote MBS>]
[-cdvt <local CDVT>]
[-lcdv <local maxCDV>]
[-rcdv<remote maxCDV>]
[-lctd <local maxCTD>]
[-rctd <remote maxCTD>]
[-cc <OAM CC Cnfg>]
[-stat <Stats Cnfg>]
[-frame <frame discard>]
[-mc <maximum cost>]Syntax Description
Related Commands
addcon, delcon, dspcon, dspcons, dspconstats
Attributes
cnfconsegep
Configure Segment Endpoint for a Connection
Configures a connection as a segment endpoint. When both VPI and VCI are present, the segment endpoint is a F5 flow endpoint (for VCCs). When the optional VCI is not present, the segment endpoint is a F4 flow endpoint (for VPCs). Use this command only for established calls.
![]()
Note
Before executing this command, you be sure continuity checking is de-activated. If you leave it on, continuity check failure occurs for the connection. Use cnfconsegep in conjunction with conntrace for fault isolation.
Command(s) on Which Command Executes
PXM-45
Syntax
cnfconsegep <portid>< vpi >[vci]Syntax Description
portid
See PNNI Format.
vpi
VPI of the connection
vci
VCI of the connection
Related Commands
cnfoamsegep, dspoamsegep, delconsegep, dspconsegep
Attributes
Examples
None.
cnfmbsdft
Port Management: Configure Default MBS
Configures the default MBS for cells received on the port. The new configuration applies to new incoming calls, not existing calls. This command can be used regardless of the state of the port.
Command(s) on Which Command Executes
PXM-45
Syntax
cnfmbsdft <portid><service_category>[num-of-cell]:Syntax Description
portid
See PNNI Format.
service_category
ATM 4.0 service category, either cbr, rtvbr, nrtvbr, ubr, or abr.
•
rtvbr = real time variable bit rate
•
nrtvbr = non-real time variable bit rate
num-of-cell
Integer. The MBS is expressed in cells.
Range: (0 through 2147483647)
Default: set by the platform (1024). If this parameter is not specified, the default is used/restored.
Related Commands
dspmbsdft
Attributes
Examples
None unless errors occur.
cnfoamsegep
Port Management: Configure OAM Segment Endpoint on a Port
Define the port as a segment endpoint for F4 and F5 OAM flow. This command does not take effective for existing connections, and only does for newly established calls. This command can be used regardless of the state of the port.
Command(s) on Which Command Executes
PXM-45
Syntax
cnfoamsegep <portid>[{yes | no}]Syntax Description
portid
See PNNI Format.
yes
The port is configured as a segment endpoint, and is a segment endpoint for all connections on this port.
no
The port is not a segment endpoint.
Default = no
Related Commands
dspoamsegep, cnfconsegep, delconsegep
Attributes
Examples
None unless errors occur.
delcon
Delete Connection
Use the delcon command to delete a connection. Delete the connection at both ends—first at the master end, then at the slave.
Card(s) on Which Command Executes
AXSM
Syntax
delcon <ifnum> <vpi> <vci>Syntax Description
ifnum
The logical port where the connection exists. The range is 1-60.
vpi
The VPI of the connection.
vci
The VCI of the connection.
Related Commands
dspcon, addcon, cnfcon
Attributes
delcons
Delete Connections
Delete a range of ATM connections.
![]()
CautionBefore entering this command, you need to know exactly how many connections you need to delete. This command starts deleting connection endpoints in lexicographic order ( dspcons displays in the same order). Incorrect of this command could result in deletion of more endpoints than necessary, and repairing such damage could be very costly.
Card(s) on Which Command Executes
AXSM
Syntax
delcons <ifNum> <vpi> <vci> [-num <num. conns to del>] [-verbose < 1 | 0 >]Syntax Description
Related Commands
None
Attributes
delconsegep
Operational Commands: Remove Segment Endpoint of a Connection
Removes a segment endpoint on a connection. When both VPI and VCI are present, the segment endpoint is a F5 flow endpoint (for VCCs). When the optional VCI is not present, the segment endpoint is a F4 flow endpoint (for VPCs).
Card(s) on Which Command Executes
PXM-45
Syntax
delconsegep <portid>vpi[vci]Syntax Description
portid
See PNNI Format.
vpi
VPI of the connection
vci
VCI of the connection
Related Commands
cnfoamsegep, dspoamsegep, cnfconsegep, dspconsegep
Attributes
Examples
dncon
Down Connection
Administratively deactivates (or "downs") so you can modify or troubleshoot the network. This operation applies to only SPVCs. To reactivate the connection, use upcon.
Card(s) on Which Command Executes
AXSM
Syntax
dncon <ifNum> <vpi> <vci>Syntax Description
Related Commands
upcon
Attributes
dspabrtparmdft
Display ABR Traffic Parameters Default
Displays the default ABR parameters for a logical port under PNNI.
Card(s) on Which Command Executes
PXM-45
Syntax
dspabrtparmdft <portid>
Syntax Description
portid has the format [shelf.]slot[:subslot].port[:subport]
Related Commands
addcon, cnfabr, cnfabrtparmdft
Attributes
Example
Display the default ABR parameters on portid 1:1.1:1.
Default ABR Traffic Parameters For: 1:1.1:1-----------------------------------RIF : 7 (= 1/512)RDF : 4 (= 1/4096)TBE : 1048320 (Cells)NRM : 5 (= 32 Cells)TRM : 8 (= 100 msec)ADTF: 50 (= 0.50 Sec)CDF : 7 (= 1/2)FSD : 0 (microSec)dspcdvtdft
Port Management: Show Default CDVT
Displays the default CDVT set for the port.
Card(s) on Which Command Executes
PXM-45
Syntax
dspcdvtdft <portid>Syntax Description
portid
See PNNI Format.
Related Commands
dspcdvtdft, cnfcdvtdft
Attributes
Examples
dspcon
Display Connection
Display information about an SPVC. The contents of the display on the AXSM and the PXM-45 slightly differ. On both cards, the dspcon output appears in sections to make the information easier to sort.
Most of the information in the dspcon output comes from addcon execution. See the addcon description for more information. Also, executing cnfpnni-intf can affect the dspcon output.
Display Connection on the PXM-45
On the PXM-45, dspcon shows the following connection identifiers:
•
NSAP address, status, and ownership of local and remote ends of the connection. The display shows whether a particular endpoint is the master or slave.
The provisioning parameters in the display show:
•
Connection type of VPC or VCC.
•
Service type and compliance (for example, UBR for service type and UBR.1 for ATM Forum compliance).
•
Bearer class.
•
Whether continuity checking or frame discard are enabled (see addcon description).
•
Cause of the last failure. This field can also show that no errors have occurred since the connection was first added by displaying "SPVC Established." If a failure occurred, the Attempts field shows the number of times the system attempted to re-establish service. If no failures have occurred, the Attempts field contains a 0.
•
L-Util and R-Util are the local and remote percent of utilization assigned to the connection. Currently, the default of 100% is the only value.
•
Cost values for the connection's route: the two fields in this category are Max Cost and Routing Cost. The Max Cost is a cost-per-link configured for a service type (such as UBR) through the cnfpnni-intf command. When you add the SPVC through addcon, you can specify a maximum routing cost through the maximum cost (maxcost) parameter. The maxcost represents the maximum cost for an individual connection. The system uses the cost-per-link for the service type and the maxcost for the connection to determine whether a route costs too much. After the system creates a route, the total number of links yields the Routing Cost.
The default cost-per-link is 5040, so if a particular service type uses the default and a route consists of 4 links, the Routing Cost is 20160. If the dspspvc display shows that Max Cost is -1, no limit was specified through cnfpnni-intf, and the resulting Routing Cost is 0.•
Broadcast type: point-to-point or multicast.
The Traffic Parameters section shows the standard parameters PCR, SCR, and CDV in the receive and transmit directions.
Display Connection on the AXSM
On the AXSM, dspcon shows the following connection identifiers:
•
NSAP address, logical port, VPI/VCI, status, and ownership of local and remote ends of the connection. The display shows whether a particular endpoint is the master or slave.
The provisioning parameters in the display show:
•
Connection type of VPC or VCC.
•
Service type (for example, ABR)
•
A number indicating the controller. For example, 2 refers to PNNI.) The addcontroller command specifies the controller.)
•
The administrative state is either up or down. This state results from addcon or dncon/upcon.
•
The operational state is either OK or failed. The operational state can apply to a connection regardless of the administrative state.
The traffic management parameters consist of:
•
Local and remote UPC parameters of PCR, MBS, CTD, CDVT, and so on. The characters "N/A" indicate that the parameter does not apply to the service type.
Other fields pertain to connection integrity:
•
OAM connectivity check enable or disable
•
Loopback test enable/disable and loopback type.
•
Round trip delay in microseconds. This field is non-zero only if you previously executed tstdelay.
The dspcon command requires a unique connection identifier. If you do not have the information to identify a connection, execute dspcons. On the AXSM, dspcons identifies all the connections on the AXSM. On the PXM-45, dspcons identifies all the connections on the node. (See dspcons description).
Card(s) on Which Command Executes
AXSM, PXM-45
Syntax
On the AXSM:
dspcon <ifNum> <vpi> <vci>On the PXM-45:
dspcon <portid> <vpi> <vci>Syntax Description
Related Commands
addcon, dspcons, cnfcon
Attributes
Examples
Display connection 2 20 1000 on the current AXSM.
ITNODE3.1.AXSM.a > dspcon 2 20 1000--------------------------------------------------------------------------Local : NSAP Address vpi vci(S) 4700918100000000107B65F27C00000101180200 20 1000Remote : NSAP Address vpi vci(M) 4700918100000000107B65F30C0000010B180200 20 1000--------------------------------------------------------------------------Conn. Type : VCC Admn Status : ADMN-UPService Type : abrstd Oper Status : OKController : 2 Record # : 18--------------------------------------------------------------------------Local PCR : 50 Remote PCR : 50Local SCR : N/A Remote SCR : N/ALocal CDV : N/A Remote CDV : N/ALocal CTD : N/A Remote CTD : N/ALocal MBS : N/A Remote MBS : N/AMax Cost : -1 Frame discard: NLocal CDVT : 250000--------------------------------------------------------------------------OAM CC Config : DISABLED Statistics : DISABLED--------------------------------------------------------------------------Loopback Type : No Lpbk | Dir: N/A | Status: No Lpbk | RTD: 0us--------------------------------------------------------------------------Type <CR> to continue, Q<CR> to stop:--------------------------------------------------------------------------Port side Tx : normal Swth side Tx : normalPort side Rx : normal Swth side Rx : normal--------------------------------------------------------------------------I-AIS/RDI E-AIS/RDI CONDITIONED CCFAIL IfFail Mismatch LMI-ABITNO NO NO NO NO NO NO--------------------------------------------------------------------------Internal VSVD config : No CnfgExternal VSVD config : No CnfgLocal MCR : 50 cells/secondRemote MCR : 50 cells/secondInitial cell rate (ICR) : 50 cells/secondACR decrease factor (ADTF) : 50 x 10 millisecRate decrease factor (RDF) : 4Rate increase factor (RIF) : 7Cells per forward RM (NRM) : 5Time between forward RM (TRM) : 8cutoff decrease factor (CDF) : 7fixed round trip delay (FRTT) : 0 microsecondstransient buffer exposure (TBE) : 1048320 cells--------------------------------------------------------------------------On the CLI of the PXM-45, display connection 20 100 on 11:1.1:2.
Unknown.7.PXM.a > dspcon 11:1.1:2 20 100Port Vpi Vci Owner State-------------------------------------------------------------------------Local 11:1.1:2 20.100 MASTER FAILAddress: 47.00918100000000107b65f33d.0000010b1802.00Remote 11:1.1:2 10.100 SLAVE FAILAddress: 47.00918100000000107b65f33d.0000010b1802.00-------------------- Provisioning Parameters --------------------Connection Type: VCC Cast Type: Point-to-PointService Category: CBR Conformance: CBR.1Bearer Class: BCOB-XLast Fail Cause: SPVC Established Attempts: 0Continuity Check: Disabled Frame Discard: DisabledL-Utils: 100 R-Utils: 100 Max Cost: -1 Routing Cost: 0---------- Traffic Parameters ----------Tx PCR: 50 Rx PCR: 50Tx CDV: N/A Rx CDV: N/ATx CTD: N/A Rx CTD: N/ADisplay information for VPI/VCI 10 100 on port ID 1:1.1:1. In this case, port ID and remote and local NSAP addresses are the same, so the connection is a DAXCON. Also, the Max Cost is -1. The Max Cost of -1 means no cost-per-link was specified for UBR service, and therefore the Routing Cost is 0.
node19.8.PXM.a > dspcon 1:1.1:1 10 100Port Vpi Vci Owner State-------------------------------------------------------------------------Local 1:1.1:1 10.100 SLAVE OKAddress: 47.00918100000000001a53c82d.000001011801.00Remote 1:1.1:1 11.101 MASTER OKAddress: 47.00918100000000001a53c82d.000001011801.00-------------------- Provisioning Parameters --------------------Connection Type: VCC Cast Type: Point-to-PointService Category: UBR Conformance: UBR.1Bearer Class: BCOB-XLast Fail Cause: SPVC Established Attempts: 0Continuity Check: Disabled Frame Discard: DisabledL-Utils: 100 R-Utils: 100 Max Cost: -1 Routing Cost: 0---------- Traffic Parameters ----------Tx PCR: 14 Rx PCR: 14Tx SCR: 3 Rx SCR: 3Tx MBS: 1 Rx MBS: 1Tx CDVT: -1 Rx CDVT: -1Tx CDV: N/A Rx CDV: N/ATx CTD: N/A Rx CTD: N/Adspconinfo
Display Summaries of Connection Information (SPVCs Only)
The dspconinfo runs on the PXM-45 and lists the total number SPVCs on each PNNI port on the node. For each port, the display shows:
•
Number of active connections
•
Number of failed connections
•
Total number of connections
Card(s) on Which Command Executes
PXM-45
Syntax
dspconinfo
Syntax Description
This command takes no parameters.
Related Commands
none
Attributes
Example
Display the SPVC summaries for the current node. This example shows all connections as failed.
popeye10.7.PXM.a > dspconinfoLocal Port #Active #Failed #Total---------------------------------------------6:1.4:4 0 1 16:1.5:5 0 19800 1980012:1.1:1 0 10001 1000114:1.1:1 0 10000 1000014:1.2:2 0 19900 19900dspcons
Display Connections—Display basic information for all connections.
The default usage of dspcons means no parameters and causes all available information for the connections to appear. To narrow the scope of the output, use one or more optional parameters.
The dspcons command runs on the CLI of either the AXSM or the PXM-45. The set of optional parameters and the output are different on these cards. See the sections, "Syntax Description (PXM-45)" and "Syntax Description (AXSM)" for the card-specific parameters. On the AXSM, the columns at the head of the information fields are:
When you execute dspcons on the CLI of the PXM-45, the output shows:
Card(s) on Which Command Executes
PXM-45, AXSM
Syntax (PXM-45)
dspcons [-port portid] [-vpi starting-vpi] [-vci starting vci] [-state {fail|ais|abit|ok|down}] [-owner {master|slave}]Syntax Description
(PXM-45)
Syntax (AXSM)
dspcons [-conn <conn id>] [-filt <filter options>] [-if <intf no>] [-vpi <vpi filter>] [-vci <vci filter>]Syntax Description
(AXSM)
Related Commands
dspcon, addcon, cnfcon, delcon, dncon, upcon
Attributes
Examples
Display connections on the current AXSM. In this example, only one master endpoint appears.
GN.6.AXSM.a > dspconsrecord Identifier Type SrvcType M/S Upld Admn Alarm------ ---------- ---- -------- --- ---- ---- -----0 02 0010 00100 VCC cbr1 S 016cfdb2 UP none2 02 0010 00200 VCC vbr1rt S 016cfe00 UP none4 02 0010 00300 VCC vbr2rt S 016cfe54 UP none6 02 0010 00400 VCC vbr3rt S 016cfea0 UP none8 02 0010 00500 VCC vbr1nrt S 016cfeef UP none10 02 0010 00600 VCC vbr2nrt S 016cff42 UP none12 02 0010 00700 VCC vbr3nrt S 016cff95 UP none14 02 0010 00800 VCC ubr1 S 016cffe4 UP none16 02 0010 00900 VCC ubr2 S 016d0034 UP none1 02 0020 00100 VCC cbr1 S 016cfdd7 UP none3 02 0020 00200 VCC vbr1rt S 016cfe2a UP none5 02 0020 00300 VCC vbr2rt S 016cfe7a UP none7 02 0020 00400 VCC vbr3rt S 016cfec6 UP none9 02 0020 00500 VCC vbr1nrt S 016cff17 UP none11 02 0020 00600 VCC vbr2nrt S 016cff6d UP none13 02 0020 00700 VCC vbr3nrt S 016cffbe UP none15 02 0020 00800 VCC ubr1 S 016d000b UP none17 02 0020 00900 VCC ubr2 S 016d005c UP none18 02 0020 01000 VCC abrstd S 016d0088 UP none20 21 0001 00000 VPC cbr1 M 016d01ee UP noneType <CR> to continue, Q<CR> to stop:Display all connections by entering dspcons on the CLI of the PXM-45.
Unknown.7.PXM.a > dspconsLocal Port Vpi.Vci Remote Port Vpi.Vci State Owner----------------------------+-----------------------------+-------+------3:1.1:1 20 0 6:1.1:1 20 0 OK MASTERLocal Addr: 47.00918100000000107b65f33d.000001031801.00Remote Addr: 47.00918100000000107b65f33d.000001061801.005:1.1:1 100 100 5:1.1:1 100 200 OK SLAVELocal Addr: 47.00918100000000107b65f33d.000001051801.00Remote Addr: 47.00918100000000107b65f33d.000001051801.005:1.1:1 100 200 5:1.1:1 100 100 OK MASTERLocal Addr: 47.00918100000000107b65f33d.000001051801.00Remote Addr: 47.00918100000000107b65f33d.000001051801.006:1.1:1 20 0 3:1.1:1 20 0 OK SLAVELocal Addr: 47.00918100000000107b65f33d.000001061801.00Remote Addr: 47.00918100000000107b65f33d.000001031801.006:1.1:1 100 100 6:1.1:1 100 200 OK SLAVELocal Addr: 47.00918100000000107b65f33d.000001061801.00Remote Addr: 47.00918100000000107b65f33d.000001061801.006:1.1:1 100 200 6:1.1:1 100 100 OK MASTERLocal Addr: 47.00918100000000107b65f33d.000001061801.00Remote Addr: 47.00918100000000107b65f33d.000001061801.006:1.1:1 200 100 6:2.1:3 200 200 OK SLAVEType <CR> to continue, Q<CR> to stop:6:1.1:1 100 200 6:1.1:1 100 100 OK MASTERLocal Addr: 47.00918100000000107b65f33d.000001061801.00Remote Addr: 47.00918100000000107b65f33d.000001061801.006:1.1:1 200 100 6:2.1:3 200 200 OK SLAVEType <CR> to continue, Q<CR> to stop:Local Addr: 47.00918100000000107b65f33d.000001061801.00Remote Addr: 47.00918100000000107b65f33d.000001061803.006:2.1:3 200 200 6:1.1:1 200 100 OK MASTERLocal Addr: 47.00918100000000107b65f33d.000001061803.00Remote Addr: 47.00918100000000107b65f33d.000001061801.009:1.3:3 10 100 Routed 0 0 FAIL SLAVELocal Addr: 47.00918100000000107b65f33d.000001091803.00Remote Addr: 00.000000000000000000000000.000000000000.0011:1.1:2 10 100 11:1.1:2 20 100 OK SLAVELocal Addr: 47.00918100000000107b65f33d.0000010b1802.00Remote Addr: 47.00918100000000107b65f33d.0000010b1802.00Local Port Vpi.Vci Remote Port Vpi.Vci State Owner----------------------------+-----------------------------+-------+------11:1.1:2 20 100 11:1.1:2 10 100 OK MASTERLocal Addr: 47.00918100000000107b65f33d.0000010b1802.00Remote Addr: 47.00918100000000107b65f33d.0000010b1802.00dspconsegep
Display Connection Segment Endpoint
Displays OAM segment endpoint for a connection endpoint. When both VPI and VCI are present, the segment endpoint is a F5 flow endpoint (for VCCs). When the optional VCI is not present, the segment endpoint is a F4 flow endpoint (for VPCs). This command is used only for established calls.
Card(s) on Which Command Executes
PXM-45
Syntax
dspconsegep <portid>vpi[vci]Syntax Description
portid
See PNNI Format.
vpi
The VPI of the connection.
vci
The VCI of the connection.
Related Commands
cnfoamsegep, dspoamsegep, cnfconsegep, delconsegep
Attributes
dspmbsdft
Port Management: Show Default MBS
Displays the default MBS configured for the port.
Syntax
dspmbsdft <portid>Syntax Description
portid
See PNNI Format.
Related Commands
cnfmbsdft
Attributes
Examples
dsppncon
Call Control Operations: Show Call Info
Displays information for an active call. The displayed call information corresponds to the objects described in the portCallTable and portAbrCallTable MIBs. This command can be issued at any node in the route path.
Syntax
dsppncon <portid><vpi><[vci]>Syntax Description
portid
See PNNI Format.
vpi
VPI for the call.
vci
VCI for the call. If no VCI is specified, this is a VP connection.
Examples
dsppncon 4.2 2 42Port : 4.2 VPI : 2 VCI : 42CallRef: 14 CallLeafRef : 0Calling-address:47.00918100000000d058ac24a2.000000040300.00Calling-subaddress:N/ACalled-address:47.00918100000000d058ac24a2.000000040200.00Called-subaddress:N/AOE Port : 4.3 OE VPI : 2 OE VCI : 42 OE CallRef: 14OAM-Type :OAM EndpointConnection-type :SPVC Cast-type :point-to-point Bearer-class :BCOBXService-category :VBR-RT Call-clipping-susceptibility:noTx conformance :VBR.1 Rx conformance :VBR.1Tx pcr : 100 Rx pcr : 50Tx scr : 50 Rx scr : 50Tx mbs : 1024 Rx mbs : 1024Tx cdvt : 229Tx frame-discard-option :disable Rx frame-discard-option :disableMax ctd : N/AMax Tx cdv : N/A Max Rx cdv : N/AMax Tx clr : 255 Max Rx clr : 255Related Commands
dsppncons
Attributes
Examples
Non-ABR Call:
Port: 5.3 VPI: 33 VCI: 44CallRef: <call-id> CallLeafRef: <leaf-id>Calling-address: <calling AESA address>Calling-subaddress: <calling AESA sub-address>Called-address: <called AESA address>Called-subaddress: <called AESA sub-address>OE port: <oe_port_id> OE VPI: <oe_vpi> OE VCI: <oe_vci>OE callRef: <oe_callid>Call-start-time: <timestamp>Connection-type: SVC Cast-type: point-to-point Bearer-class: <bc>Service-category: CBR Call-clipping-susceptibility: noTx conformance: CBR.1 Rx conformance: CBR.1Tx pcr: <tx pcr> Rx pcr: <rx pcr>Tx scr: <tx scr> Rx scr: <rx scr>Tx mbs: <tx mbs> Rx mbs: <rx mbs>Tx cdvt: <tx cdvt> Rx cdvt: <rx cdvt>Tx frame-discard-option: disable Rx frame-discard-option: disableMax ctd: <max ctd>Max Tx cdv: <max tx cdv> Max Rx cdv: <max rx cdv>Max Tx clr: <max tx clr> Max Rx clr: <max rx clr>ABR Call
Port: 5.3 VPI: 100 VCI: 200CallRef: <call-id> CallLeafRef: <leaf-id>Calling-address: <calling AESA address>Calling-subaddress: <calling AESA sub-address>Called-address: <called AESA address>Called-subaddress: <called AESA sub-address>OE port: <oe_port_id> OE VPI: <oe_vpi> OE VCI: <oe_vci>OE callRef: <oe_callid>Call-start-time: <timestamp>Connection-type: SVC Cast-type: point-to-point Bearer-class: <bc>Service-category: ABR Call-clipping-susceptibility: noTx conformance: ABRTx pcr: <tx pcr> Rx pcr: <rx pcr>Tx mcr: <tx mcr> Rx mcr: <rx mcr>Tx icr: <tx icr> Rx icr: <rx icr>Tx rif: <tx rif> Rx rif: <rx rif>Tx rdf: <tx rdf> Rx rdf: <rx rdf>Tx tbe: <tx tbe> Rx tbe: <rx tbe>Tx nrm: <tx nrm> Rx nrm: <rx nrm>Tx trm: <tx trm> Rx trm: <rx trm>Tx adtf: <tx adtf> Rx adtf: <rx adtf>Tx cdf: <tx cdf> Rx cdf: <rx cdf>Tx frame-discard-option: disable Rx frame-discard-option: disableFrtt: <frtt> Max ctd: <max ctd>Max Tx cdv: <max tx cdv> Max Rx cdv: <max rx cdv>Max Tx clr: <max tx clr> Max Rx clr: <max rx clr>dsppncons
Call Control Operations: Show Calls
Displays a summary of active calls on one port or all ports. This command can be issued at any node.
Syntax
dsppncons[-port portid][-vpi starting-vpi][-vci starting-vci][-type {p2p | p2mp}]Syntax Description
-portid
Keyword that sets the port ID. See PNNI Format.
-vpi
Keyword that specifies the VPI at which to begin displaying. This keyword can only be used if portid is specified.
-vci
Keyword that specifies the VCI at which to begin displaying. This keyword can only be used if -vpi is used.
-type
Keyword that sets the cast type. Only connections of this cast type will be displayed.
Related Commands
dsppncon
Attributes
Examples
Port VPI VCI CallRef X-Port VPI VCI CallRef Type OAM-Type1:1.2:2 1 100 33 1:1.2:2 1 101 32 PTP NoCalling-Addr:47.00918100000000107be92f3d.000001011802.00Called-Addr:47.00918100000000107be92f3d.000001011802.001:1.2:2 1 101 32 1:1.2:2 1 100 33 PTP NoCalling-Addr:47.00918100000000107be92f3d.000001011802.00Called-Addr:47.00918100000000107be92f3d.000001011802.001:1.2:2 2 200 34 1:1.6:6 0 49 8388609 PTP NoCalling-Addr:47.00918100000000107be92f3f.000001011804.00Called-Addr:47.00918100000000107be92f3d.000001011802.001:1.6:6 0 49 8388609 1:1.2:2 2 200 34 PTP NoCalling-Addr:47.00918100000000107be92f3f.000001011804.00Called-Addr:47.00918100000000107be92f3d.000001011802.00dsppnconstats
Call Control Operations: Show Call Statistics
Displays call statistics for the port.
Card(s) on Which Command Executes
PXM-45
Syntax
dsppnconstats <portid>Syntax Description
portid
See PNNI Format.
Related Commands
clrpnconstats
Attributes
Examples
Call Statistics for <portid>Incoming Call Attempts: 0 Outgoing Call Attempts: 0Incoming Call Success: 0 Outgoing Call Success: 0Incoming Call Failures: 0 Outgoing Call Failures: 0Incoming Filtering Failures:0 Outgoing Filtering Failures:0Incoming Routing Failures: 0 Outgoing Routing Failures: 0Incoming CAC Failures: 0 Outgoing CAC Failures: 0Incoming Timer Failures: 0 Outgoing Timer Failures: 0Incoming Crankback Failures:0 Outgoing Crankback Failures:0Output Description
upcon
Up Connection
Activate a connection that was previously brought down by the dncon command. (The typical purpose of dncon is some form of operational modification or troubleshooting.)
Card(s) on Which Command Executes
AXSM
Syntax
upcon <ifNum > <vpi> <vci>Syntax Description
Related Commands
dncon
Attributes
upport
Up Port
The upport command enables (or "ups") a logical port. The usage of upport follows dnport. See the dnport description for information on the use of these commands.
Use dspports or dspport as needed to determine the port to enable or to see the status of the port after you enable it.
Card(s) on Which Command Executes
AXSM
Syntax
upport <ifNum>Syntax Description
Related Commands
dspport, dspports, dnport
Attributes
Enable port 1 on the current card.
chicago.1.AXSM.a >upport 1