This chapter explains how to maintain the Cisco ME 2600X shelf installation.
Purpose | This procedure explains how to clean the fiber connectors. |
Tools/Equipment | |
Prerequisite Procedures | None |
Required/As Needed | Required |
Onsite/Remote | Onsite |
Security Level | None |
Step 1 | Using an inspection microscope, inspect each fiber connector for dirt, cracks, or scratches. | ||
Step 2 | Replace any damaged fiber connectors.
| ||
Step 3 | Complete the Cleaning Fiber Connectors with CLETOP as necessary. | ||
Step 4 | Complete the Cleaning the Fiber Adapters as necessary. | ||
Step 5 | Stop. You have completed this procedure. |
Purpose | This task explains how to clean the fiber connectors with CLETOP. |
Tools/Equipment | |
Prerequisite Procedures | None |
Required/As Needed | Required |
Onsite/Remote | Onsite |
Security Level | None |
Purpose | This task explains how to clean the fiber adapters. |
Tools/Equipment | CLETOP stick swab |
Prerequisite Procedures | None |
Required/As Needed | Required |
Onsite/Remote | Onsite |
Security Level | None |
Purpose | This procedure describes how to replace the fan-tray assembly in the Cisco ME 2600X shelf. |
Tools/Equipment | Number-2 Phillips Dynamometric screwdriver |
Prerequisite Procedures | |
Required/As Needed | Required |
Onsite/Remote | Onsite |
Security Level | None |
![]() Caution | Do not operate the shelf without an air filter. |
![]() Note | The estimated time for a skilled technician to replace an equipment fan or fan tray is 2 minutes. |
![]() Note | The fan or the cooling unit can be replaced without service interruption. |
![]() Caution | Do not force a fan-tray module into place. Doing so can damage either the connectors on the fan tray or the connectors on the back panel of the shelf assembly, or both. |
![]() Note | Error messages appear on the fan-tray LED, when the fan-tray module is removed from the shelf or when one fan is not working. |
Purpose | This procedure explains how to replace the air filter of the Cisco ME 2600X shelf. |
Tools/Equipment | #2 Phillips Dynamometric screwdriver |
Prerequisite Procedures | |
Required/As Needed | Required |
Onsite/Remote | Onsite |
Security Level | None |
![]() Caution | Do not operate the shelf without an air filter. |
![]() Note | Replacement of an air filter is recommended every 60 days. |