shutdown
Use the shutdown interface configuration command on the switch stack or on a standalone switch to disable an interface. Use the no form of this command to restart a disabled interface.
shutdown
no shutdown
Syntax Description
This command has no arguments or keywords.
Defaults
The port is enabled (not shut down).
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
The shutdown command causes a port to stop forwarding. You can enable the port with the no shutdown command.
The no shutdown command has no effect if the port is a static-access port assigned to a VLAN that has been deleted, suspended, or shut down. The port must first be a member of an active VLAN before it can be re-enabled.
The shutdown command disables all functions on the specified interface.
This command also marks the interface as unavailable. To see if an interface is disabled, use the show interfaces privileged EXEC command. An interface that has been shut down is shown as administratively down in the display.
Examples
These examples show how to disable and re-enable a port:
Switch(config)# interface gigabitethernet1/0/2
Switch(config-if)# shutdown
Switch(config)# interface gigabitethernet1/0/2
Switch(config-if)# no shutdown
You can verify your settings by entering the show interfaces privileged EXEC command.
Related Commands
|
|
show interfaces |
Displays the statistical information specific to all interfaces or to a specific interface. |
shutdown vlan
Use the shutdown vlan global configuration command on the switch stack or on a standalone switch to shut down (suspend) local traffic on the specified VLAN. Use the no form of this command to restart local traffic on the VLAN.
shutdown vlan vlan-id
no shutdown vlan vlan-id
Syntax Description
vlan-id |
ID of the VLAN to be locally shut down. The range is 2 to 1001. VLANs defined as default VLANs under the VLAN Trunking Protocol (VTP), as well as extended-range VLANs (greater than 1005) cannot be shut down. The default VLANs are 1 and 1002 to 1005. |
Defaults
No default is defined.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
The shutdown vlan command does not change the VLAN information in the VTP database. The command shuts down local traffic, but the switch still advertises VTP information.
Examples
This example shows how to shut down traffic on VLAN 2:
Switch(config)# shutdown vlan 2
You can verify your setting by entering the show vlan privileged EXEC command.
Related Commands
|
|
shutdown (config-vlan mode) |
Shuts down local traffic on the VLAN when in config-VLAN mode (accessed by the vlan vlan-id global configuration command). |
small-frame violation rate
Use the small-frame violation rate pps interface configuration command on the switch stack or on a standalone switch to configure the rate (threshold) for an interface to be error disabled when it receives VLAN-tagged packets that are small frames (67 bytes or less) at the specified rate. Use the no form of this command to return to the default setting.
small-frame violation rate pps
no small-frame violation rate pps
Syntax Description
pps |
Specify the threshold at which an interface receiving small frames will be error disabled. The range is 1 to 10,000 packets per second (pps). |
Defaults
This feature is disabled.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
This command enables the rate (threshold) for a port to be error disabled when it receives small frames. Small frames are considered packets that are 67 frames or less.
Use the errdisable detect cause small-frame global configuration command to globally enable the small-frames threshold for each port.
You can configure the port to be automatically re-enabled by using the errdisable recovery cause small-frame global configuration command. You configure the recovery time by using the errdisable recovery interval interval global configuration command.
Examples
This example shows how to enable the small-frame arrival rate feature so that the port is error disabled if incoming small frames arrived at 10,000 pps.
Switch(config)# interface gigabitethernet2/0/1
Switch(config-if)# small-frame violation rate 10000
You can verify your setting by entering the privileged EXEC command.
Related Commands
|
|
errdisable detect cause small-frame |
Allows any switch port to be put into the error-disabled state if an incoming frame is smaller than the minimum size and arrives at the specified rate (threshold). |
errdisable recovery cause small-frame |
Enables the recovery timer. |
show interfaces |
Displays the interface settings on the switch, including input and output flow control. |
snmp-server enable traps
Use the snmp-server enable traps global configuration command on the switch stack or on a standalone switch to enable the switch to send Simple Network Management Protocol (SNMP) notifications for various traps or inform requests to the network management system (NMS). Use the no form of this command to return to the default setting.
snmp-server enable traps [ bgp | bridge [ newroot ] [ topologychange ] | cluster | config | copy-config | cpu threshold | {dot1x [auth-fail-vlan | guest-vlan | no-auth-fail-vlan | no-guest-vlan] } | entity | envmon [ fan | shutdown | status | supply | temperature ] | flash [ insertion | removal ] | fru-ctrl | hsrp | ipmulticast | | mac-notification [ change ] [ move ] [ threshold ] | msdp | ospf [ cisco-specific | errors | lsa | rate-limit | retransmit | state-change ] | pim [ invalid-pim-message | neighbor-change | rp-mapping-change ] | port-security [ trap-rate value ] | power-ethernet { group name | police } | rtr | snmp [ authentication | coldstart | linkdown | linkup | warmstart ] | stackwise | storm-control trap-rate value | stpx [ inconsistency ] [ root-inconsistency ] [ loop-inconsistency ] | syslog | tty | vlan-membership | vlancreate | vlandelete | vtp ]
no snmp-server enable traps [ bgp | bridge [ newroot ] [ topologychange ] | cluster | config | copy-config | cpu threshold | {dot1x [auth-fail-vlan | guest-vlan | no-auth-fail-vlan | no-guest-vlan] } | entity | envmon [ fan | shutdown | status | supply | temperature ] | flash [ insertion | removal ] | fru-ctrl | hsrp | ipmulticast | | mac-notification [ change ] [ move ] [ threshold ] | msdp | ospf [ cisco-specific | errors | lsa | rate-limit | retransmit | state-change ] | pim [ invalid-pim-message | neighbor-change | rp-mapping-change ] | port-security [ trap-rate ] | power-ethernet { group name | police } | rtr | snmp [ authentication | coldstart | linkdown | linkup | warmstart ] | stackwise | storm-control trap-rate | stpx [ inconsistency ] [ root-inconsistency ] [ loop-inconsistency ] | syslog | tty | vlan-membership | vlancreate | vlandelete | vtp ]
Syntax Description
bgp |
(Optional) Enable Border Gateway Protocol (BGP) state-change traps. Note This keyword is available only when the IP services feature set is enabled on the switch or stack master. |
bridge [ newroot ] [ topologychange ] |
(Optional) Generate STP bridge MIB traps. The keywords have these meanings:
- newroot —(Optional) Enable SNMP STP Bridge MIB new root traps.
- topologychange —(Optional) Enable SNMP STP Bridge MIB topology change traps.
|
cluster |
(Optional) Enable cluster traps. |
config |
(Optional) Enable SNMP configuration traps. |
copy-config |
(Optional) Enable SNMP copy-configuration traps. |
cpu threshold |
(Optional) Allow CPU-related traps. |
dot1x [auth-fail-vlan | guest-vlan | no-auth-fail-vlan | no-guest-vlan] |
(Optional) Enable IEEE 802.1x traps. The keywords have these meanings:
- auth-fail-vlan—(Optional) Generate a trap when the port moves to the configured restricted VLAN.
- guest-vlan—(Optional) Generate a trap when the port moves to the configured guest VLAN.
- no-auth-fail-vlan—(Optional) Generate a trap when a port tries to enter the restricted VLAN, but cannot because the restricted VLAN is not configured.
- no-guest-vlan—(Optional) Generate a trap when a port tries to enter the guest VLAN, but cannot because the guest VLAN is not configured.
Note When the snmp-server enable traps dot1x command is entered (without any other keywords specified), all the IEEE 802.1x traps are enabled. |
entity |
(Optional) Enable SNMP entity traps. |
envmon [ fan | shutdown | status | supply | temperature ] |
Optional) Enable SNMP environmental traps. The keywords have these meanings:
- fan —(Optional) Enable fan traps.
- shutdown — (Optional) Enable environmental monitor shutdown traps.
- status —(Optional) Enable SNMP environmental status-change traps.
- supply — (Optional) Enable environmental monitor power-supply traps.
- temperature — (Optional) Enable environmental monitor temperature traps.
|
flash [ insertion | removal ] |
(Optional) Enable SNMP FLASH notifications. The keywords have these meanings: insertion — (Optional) Generate a trap when a switch (flash) is inserted into a stack, either physically or because of a power cycle or reload. removal — (Optional) Generate a trap when a switch (flash) is removed from a stack, either physically or because of a power cycle or reload. |
fru-ctrl |
( Optional) Generate entity field-replaceable unit (FRU) control traps. In a switch stack, this trap refers to the insertion or removal of a switch in the stack. |
hsrp |
(Optional) Enable Hot Standby Router Protocol (HSRP) traps. |
ipmulticast |
(Optional) Enable IP multicast routing traps. |
mac-notification |
(Optional) Enable MAC address notification traps. |
change |
(Optional) Enable MAC address change notification traps. |
move |
(Optional) Enable MAC address move notification traps. |
threshold |
(Optional) Enable MAC address table threshold traps. |
msdp |
(Optional) Enable Multicast Source Discovery Protocol (MSDP) traps. |
ospf [ cisco-specific | errors | lsa | rate-limit | retransmit | state-change ] |
(Optional) Enable Open Shortest Path First (OSPF) traps. The keywords have these meanings:
- cisco-specific — (Optional) Enable Cisco-specific traps.
- errors — (Optional) Enable error traps.
- lsa — (Optional) Enable link-state advertisement (LSA) traps.
- rate-limit — (Optional) Enable rate-limit traps.
- retransmit — (Optional) Enable packet-retransmit traps.
- state-change — (Optional) Enable state-change traps.
|
pim [ invalid-pim-message | neighbor-change | rp-mapping-change ] |
(Optional) Enable Protocol-Independent Multicast (PIM) traps. The keywords have these meanings:
- invalid-pim-message — (Optional) Enable invalid PIM message traps.
- neighbor-change — (Optional) Enable PIM neighbor-change traps.
- rp-mapping-change — (Optional) Enable rendezvous point (RP)-mapping change traps.
|
port-security [ trap-rate value ] |
(Optional) Enable port security traps. Use the trap-rat e keyword to set the maximum number of port-security traps sent per second. The range is from 0 to 1000; the default is 0 (no limit imposed; a trap is sent at every occurrence). |
power-ethernet { group name | police } |
(Optional) Enable power-over-Ethernet traps. The keywords have these meanings:
- group name — Enable inline power group-based traps for the specified group number or list.
- police — Enable inline power policing traps.
|
rtr |
(Optional) Enable SNMP Response Time Reporter traps. |
snmp [ authentication | coldstart | linkdown | linkup | warmstart ] |
(Optional) Enable SNMP traps. The keywords have these meanings:
- authentication — (Optional) Enable authentication trap.
- coldstart — (Optional) Enable cold start trap.
- linkdown — (Optional) Enable linkdown trap.
- linkup — (Optional) Enable linkup trap.
- warmstart — (Optional) Enable warmstart trap.
|
stackwise |
(Optional) Enable SNMP stackwise traps. |
storm-control trap-rate value |
(Optional) Enable storm-control traps. Use the trap-rat e keyword to set the maximum number of storm-control traps sent per minute. The range is 0 to 1000; the default is 0 (no limit is imposed; a trap is sent at every occurrence). |
stpx |
(Optional) Enable SNMP STPX MIB traps. The keywords have these meanings:
- inconsistency — (Optional) Enable SNMP STPX MIB Inconsistency Update traps.
- root-inconsistency — (Optional) Enable SNMP STPX MIB Root Inconsistency Update traps.
- loop-inconsistency — (Optional) Enable SNMP STPX MIB Loop Inconsistency Update traps.
|
syslog |
(Optional) Enable SNMP syslog traps. |
tty |
(Optional) Send TCP connection traps. This is enabled by default. |
vlan-membership |
(Optional) Enable SNMP VLAN membership traps. |
vlancreate |
(Optional) Enable SNMP VLAN-created traps. |
vlandelete |
(Optional) Enable SNMP VLAN-deleted traps. |
vtp |
(Optional) Enable VLAN Trunking Protocol (VTP) traps. |
Note Though visible in the command-line help strings, the fru-ctrl, insertion, and removal keywords are not supported on Catalyst 3560-X switches.
The snmp-server enable informs global configuration command is not supported. To enable the sending of SNMP inform notifications, use the snmp-server enable traps global configuration command combined with the snmp-server host host-addr informs global configuration command.
Defaults
The sending of SNMP traps is disabled.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
Specify the host (NMS) that receives the traps by using the snmp-server host global configuration command. If no trap types are specified, all trap types are sent.
When supported, use the snmp-server enable traps command to enable sending of traps or informs.
Note Informs are not supported in SNMPv1.
To enable more than one type of trap, you must enter a separate snmp-server enable traps command for each trap type.
Examples
This example shows how to send VTP traps to the NMS:
Switch(config)# snmp-server enable traps vtp
You can verify your setting by entering the show vtp status or the show running-config privileged EXEC command.
snmp-server host
Use the snmp-server host global configuration command on the switch stack or on a standalone switch to specify the recipient (host) of a Simple Network Management Protocol (SNMP) notification operation. Use the no form of this command to remove the specified host.
snmp-server host host-addr [ informs | traps ] [ version { 1 | 2c | 3 { auth | noauth | priv }] [ vrf vrf-instance ] { community-string [ notification-type ]}
no snmp-server host host-addr [ informs | traps ] [ version { 1 | 2c | 3 { auth | noauth | priv }] [ vrf vrf-instance ] community-string
Syntax Description
host-addr |
Name or Internet address of the host (the targeted recipient). |
udp-port port |
(Optional) Configure the User Datagram Protocol (UDP) port number of the host to receive the traps. The range is 0 to 65535. |
informs | traps |
(Optional) Send SNMP traps or informs to this host. |
version 1 | 2c | 3 |
(Optional) Version of the SNMP used to send the traps. These keywords are supported: 1 —SNMPv1. This option is not available with informs. 2c —SNMPv2C. 3 —SNMPv3. These optional keywords can follow the Version 3 keyword:
- auth (Optional). Enables Message Digest 5 (MD5) and Secure Hash Algorithm (SHA) packet authentication.
- noauth (Default). The noAuthNoPriv security level. This is the default if the [ auth | noauth | priv ] keyword choice is not specified.
- priv (Optional). Enables Data Encryption Standard (DES) packet encryption (also called privacy).
|
vrf vrf-instance |
(Optional) Virtual private network (VPN) routing instance and name for this host. |
community-string |
Password-like community string sent with the notification operation. Though you can set this string by using the snmp-server host command, we recommend that you define this string by using the snmp-server community global configuration command before using the snmp-server host command. Note The @ symbol is used for delimiting the context information. Avoid using the @ symbol as part of the SNMP community string when configuring this command. |
notification-type |
(Optional) Type of notification to be sent to the host. If no type is specified, all notifications are sent. The notification type can be one or more of the these keywords:
- bgp —Send Border Gateway Protocol (BGP) state change traps. This keyword is available only when the IP services feature set is enabled on the switch or the stack master.
- bridge — Send SNMP Spanning Tree Protocol (STP) bridge MIB traps.
- cluster — Send cluster member status traps.
- config —Send SNMP configuration traps.
- copy-config — Send SNMP copy configuration traps.
- cpu threshold—Allow CPU-related traps.
- entity — Send SNMP entity traps.
- envmon — Send environmental monitor traps.
- flash — Send SNMP FLASH notifications.
- fru-ctrl — Send entity FRU control traps. In the switch stack, this trap refers to the insertion or removal of a switch in the stack.
- hsrp— Send SNMP Hot Standby Router Protocol (HSRP) traps.
- ipmulticast— Send SNMP IP multicast routing traps.
- mac-notification— Send SNMP MAC notification traps.
- msdp— Send SNMP Multicast Source Discovery Protocol (MSDP) traps.
- ospf— Send Open Shortest Path First (OSPF) traps.
- pim— Send SNMP Protocol-Independent Multicast (PIM) traps.
- port-security— Send SNMP port-security traps.
- rtr— Send SNMP Response Time Reporter traps.
- snmp— Send SNMP-type traps.
- storm-control— Send SNMP storm-control traps.
- stpx— Send SNMP STP extended MIB traps.
- syslog— Send SNMP syslog traps.
- tty— Send TCP connection traps.
- udp-port port — Configure the User Datagram Protocol (UDP) port number of the host to receive the traps. The range is from 0 to 65535.
- vlan-membership— Send SNMP VLAN membership traps.
- vlancreate— Send SNMP VLAN-created traps.
- vlandelete— Send SNMP VLAN-deleted traps.
- vtp— Send SNMP VLAN Trunking Protocol (VTP) traps.
|
Note Though visible in the command-line help strings, the fru-ctrl keyword is not supported on Catalyst 3560-X switches.
Defaults
This command is disabled by default. No notifications are sent.
If you enter this command with no keywords, the default is to send all trap types to the host. No informs are sent to this host.
If no version keyword is present, the default is Version 1.
If Version 3 is selected and no authentication keyword is entered, the default is the noauth (noAuthNoPriv) security level.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
SNMP notifications can be sent as traps or inform requests. Traps are unreliable because the receiver does not send acknowledgments when it receives traps. The sender cannot determine if the traps were received. However, an SNMP entity that receives an inform request acknowledges the message with an SNMP response PDU. If the sender never receives the response, the inform request can be sent again. Thus, informs are more likely to reach their intended destinations.
However, informs consume more resources in the agent and in the network. Unlike a trap, which is discarded as soon as it is sent, an inform request must be held in memory until a response is received or the request times out. Traps are also sent only once, but an inform might be retried several times. The retries increase traffic and contribute to a higher overhead on the network.
If you do not enter an snmp-server host command, no notifications are sent. To configure the switch to send SNMP notifications, you must enter at least one snmp-server host command. If you enter the command with no keywords, all trap types are enabled for the host. To enable multiple hosts, you must enter a separate snmp-server host command for each host. You can specify multiple notification types in the command for each host.
If a local user is not associated with a remote host, the switch does not send informs for the auth (authNoPriv) and the priv (authPriv) authentication levels.
When multiple snmp-server host commands are given for the same host and kind of notification (trap or inform), each succeeding command overwrites the previous command. Only the last snmp-server host command is in effect. For example, if you enter an snmp-server host inform command for a host and then enter another snmp-server host inform command for the same host, the second command replaces the first.
The snmp-server host command is used with the snmp-server enable traps global configuration command. Use the snmp-server enable traps command to specify which SNMP notifications are sent globally. For a host to receive most notifications, at least one snmp-server enable traps command and the snmp-server host command for that host must be enabled. Some notification types cannot be controlled with the snmp-server enable traps command. For example, some notification types are always enabled. Other notification types are enabled by a different command.
The no snmp-server host command with no keywords disables traps, but not informs, to the host. To disable informs, use the no snmp-server host informs command.
Examples
This example shows how to configure a unique SNMP community string named comaccess for traps and prevent SNMP polling access with this string through access-list 10:
Switch(config)# snmp-server community comaccess ro 10
Switch(config)# snmp-server host 172.20.2.160 comaccess
Switch(config)# access-list 10 deny any
This example shows how to send the SNMP traps to the host specified by the name myhost.cisco.com. The community string is defined as comaccess :
Switch(config)# snmp-server enable traps
Switch(config)# snmp-server host myhost.cisco.com comaccess snmp
This example shows how to enable the switch to send all traps to the host myhost.cisco.com by using the community string public :
Switch(config)# snmp-server enable traps
Switch(config)# snmp-server host myhost.cisco.com public
You can verify your settings by entering the show running-config privileged EXEC command.
snmp trap mac-notification change
Use the snmp trap mac-notification change interface configuration command on the switch stack or on a standalone switch to enable the Simple Network Management Protocol (SNMP) MAC address notification trap on a specific Layer 2 interface. Use the no form of this command to return to the default setting.
snmp trap mac-notification change { added | removed }
no snmp trap mac-notification change { added | removed }
Syntax Description
added |
Enable the MAC notification trap when a MAC address is added on this interface. |
removed |
Enable the MAC notification trap when a MAC address is removed from this interface. |
Defaults
By default, the traps for both address addition and address removal are disabled.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
Even though you enable the notification trap for a specific interface by using the snmp trap mac-notification change command, the trap is generated only when you enter the snmp-server enable traps mac-notification change and the mac address-table notification change global configuration commands.
Examples
This example shows how to enable the MAC notification trap when a MAC address is added to a port:
Switch(config)# interface gigabitethernet1/0/2
Switch(config-if)# snmp trap mac-notification change added
You can verify your settings by entering the show mac address-table notification change interface privileged EXEC command.
spanning-tree backbonefast
Use the spanning-tree backbonefast global configuration command on the switch stack or on a standalone switch to enable the BackboneFast feature. Use the no form of the command to return to the default setting.
spanning-tree backbonefast
no spanning-tree backbonefast
Syntax Description
This command has no arguments or keywords.
Defaults
BackboneFast is disabled.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
You can configure the BackboneFast feature for rapid PVST+ or for multiple spanning-tree (MST) mode, but the feature remains disabled (inactive) until you change the spanning-tree mode to PVST+.
BackboneFast starts when a root port or blocked port on a switch receives inferior BPDUs from its designated switch. An inferior BPDU identifies a switch that declares itself as both the root bridge and the designated switch. When a switch receives an inferior BPDU, it means that a link to which the switch is not directly connected (an indirect link) has failed (that is, the designated switch has lost its connection to the root switch. If there are alternate paths to the root switch, BackboneFast causes the maximum aging time on the interfaces on which it received the inferior BPDU to expire and allows a blocked port to move immediately to the listening state. BackboneFast then transitions the interface to the forwarding state. For more information, see the software configuration guide for this release.
Enable BackboneFast on all supported switches to allow the detection of indirect link failures and to start the spanning-tree reconfiguration sooner.
Examples
This example shows how to enable BackboneFast on the switch:
Switch(config)# spanning-tree backbonefast
You can verify your setting by entering the show spanning-tree summary privileged EXEC command.
spanning-tree bpdufilter
Use the spanning-tree bpdufilter interface configuration command on the switch stack or on a standalone switch to prevent an interface from sending or receiving bridge protocol data units (BPDUs). Use the no form of this command to return to the default setting.
spanning-tree bpdufilter { disable | enable }
no spanning-tree bpdufilter
Syntax Description
disable |
Disable BPDU filtering on the specified interface. |
enable |
Enable BPDU filtering on the specified interface. |
Defaults
BPDU filtering is disabled.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
You can enable the BPDU filtering feature when the switch is operating in the per-VLAN spanning-tree plus (PVST+), rapid-PVST+, or the multiple spanning-tree (MST) mode.
Caution
Enabling BPDU filtering on an interface is the same as disabling spanning tree on it and can result in spanning-tree loops.
You can globally enable BPDU filtering on all Port Fast-enabled interfaces by using the spanning-tree portfast bpdufilter default global configuration command.
You can use the spanning-tree bpdufilter interface configuration command to override the setting of the spanning-tree portfast bpdufilter default global configuration command.
Examples
This example shows how to enable the BPDU filtering feature on a port:
Switch(config)# interface gigabitethernet2/0/1
Switch(config-if)# spanning-tree bpdufilter enable
You can verify your setting by entering the show running-config privileged EXEC command.
spanning-tree bpduguard
Use the spanning-tree bpduguard interface configuration command on the switch stack or on a standalone switch to put an interface in the error-disabled state when it receives a bridge protocol data unit (BPDU). Use the no form of this command to return to the default setting.
spanning-tree bpduguard { disable | enable }
no spanning-tree bpduguard
Syntax Description
disable |
Disable BPDU guard on the specified interface. |
enable |
Enable BPDU guard on the specified interface. |
Defaults
BPDU guard is disabled.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
The BPDU guard feature provides a secure response to invalid configurations because you must manually put the interface back in service. Use the BPDU guard feature in a service-provider network to prevent an interface from being included in the spanning-tree topology.
You can enable the BPDU guard feature when the switch is operating in the per-VLAN spanning-tree plus (PVST+), rapid-PVST+, or the multiple spanning-tree (MST) mode.
You can globally enable BPDU guard on all Port Fast-enabled interfaces by using the spanning-tree portfast bpduguard default global configuration command.
You can use the spanning-tree bpduguard interface configuration command to override the setting of the spanning-tree portfast bpduguard default global configuration command.
Examples
This example shows how to enable the BPDU guard feature on a port:
Switch(config)# interface gigabitethernet2/0/1
Switch(config-if)# spanning-tree bpduguard enable
You can verify your setting by entering the show running-config privileged EXEC command.
spanning-tree cost
Use the spanning-tree cost interface configuration command on the switch stack or on a standalone switch to set the path cost for spanning-tree calculations. If a loop occurs, spanning tree considers the path cost when selecting an interface to place in the forwarding state. Use the no form of this command to return to the default setting.
spanning-tree [ vlan vlan-id ] cost cost
no spanning-tree [ vlan vlan-id ] cost
Syntax Description
vlan vlan-id |
(Optional) VLAN range associated with a spanning-tree instance. You can specify a single VLAN identified by VLAN ID number, a range of VLANs separated by a hyphen, or a series of VLANs separated by a comma. The range is 1 to 4094. |
cost |
Path cost. The range is 1 to 200000000, with higher values meaning higher costs. |
Defaults
The default path cost is computed from the interface bandwidth setting. These are the IEEE default path cost values:
- 1000 Mb/s—4
- 100 Mb/s—19
- 10 Mb/s—100
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
When you configure the cost, higher values represent higher costs.
If you configure an interface with both the spanning-tree vlan vlan-id cost cost command and the spanning-tree cost cost command, the spanning-tree vlan vlan-id cost cost command takes effect.
Examples
This example shows how to set the path cost to 250 on a port:
Switch(config)# interface gigabitethernet2/0/1
Switch(config-if)# spanning-tree cost 250
This example shows how to set a path cost to 300 for VLANs 10, 12 to 15, and 20:
Switch(config-if)# spanning-tree vlan 10,12-15,20 cost 300
You can verify your settings by entering the show spanning-tree interface interface-id privileged EXEC command.
spanning-tree etherchannel guard misconfig
Use the spanning-tree etherchannel guard misconfig global configuration command to display an error message when the switch detects an EtherChannel misconfiguration. Use the no form of this command to disable the feature.
spanning-tree etherchannel guard misconfig
no spanning-tree etherchannel guard misconfig
Syntax Description
This command has no arguments or keywords.
Defaults
EtherChannel guard is enabled on the switch.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
When the switch detects an EtherChannel misconfiguration, this error message appears:
PM-4-ERR_DISABLE: Channel-misconfig error detected on [chars], putting [chars] in err-disable state.
To show switch ports that are in the misconfigured EtherChannel, use the show interfaces status err-disabled privileged EXEC command. To verify the EtherChannel configuration on a remote device, use the show etherchannel summary privileged EXEC command on the remote device.
When a port is in the error-disabled state because of an EtherChannel misconfiguration, you can bring it out of this state by entering the errdisable recovery cause channel-misconfig global configuration command, or you can manually re-enable it by entering the shutdown and no shut down interface configuration commands.
Examples
This example shows how to enable the EtherChannel guard misconfiguration feature:
Switch(config)# spanning-tree etherchannel guard misconfig
You can verify your settings by entering the show spanning-tree summary privileged EXEC command.
Related Commands
|
|
errdisable recovery cause channel-misconfig |
Enables the timer to recover from the EtherChannel misconfiguration error-disabled state. |
show etherchannel summary |
Displays EtherChannel information for a channel as a one-line summary per channel-group. |
show interfaces status err-disabled |
Displays the interfaces in the error-disabled state. |
spanning-tree extend system-id
Use the spanning-tree extend system-id global configuration command on the switch stack or on a standalone switch to enable the extended system ID feature.
spanning-tree extend system-id
Note Though visible in the command-line help strings, the no version of this command is not supported. You cannot disable the extended system ID feature.
Syntax Description
This command has no arguments or keywords.
Defaults
The extended system ID is enabled.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
The switch supports the IEEE 802.1t spanning-tree extensions. Some of the bits previously used for the switch priority are now used for the extended system ID (VLAN identifier for the per-VLAN spanning-tree plus [PVST+] and rapid PVST+ or as an instance identifier for the multiple spanning tree [MST]).
The spanning tree uses the extended system ID, the switch priority, and the allocated spanning-tree MAC address to make the bridge ID unique for each VLAN or multiple spanning-tree instance. Because the switch stack appears as a single switch to the rest of the network, all switches in the stack use the same bridge ID for a given spanning tree. If the stack master fails, the stack members recalculate their bridge IDs of all running spanning trees based on the new MAC address of the stack master.
Support for the extended system ID affects how you manually configure the root switch, the secondary root switch, and the switch priority of a VLAN. For more information, see the “spanning-tree mst root” and the “spanning-tree vlan” sections.
If your network consists of switches that do not support the extended system ID and switches that do support it, it is unlikely that the switch with the extended system ID support will become the root switch. The extended system ID increases the switch priority value every time the VLAN number is greater than the priority of the connected switches.
spanning-tree guard
Use the spanning-tree guard interface configuration command on the switch stack or on a standalone switch to enable root guard or loop guard on all the VLANs associated with the selected interface. Root guard restricts which interface is allowed to be the spanning-tree root port or the path-to-the root for the switch. Loop guard prevents alternate or root ports from becoming designated ports when a failure creates a unidirectional link. Use the no form of this command to return to the default setting.
spanning-tree guard { loop | none | root }
no spanning-tree guard
Syntax Description
loop |
Enable loop guard. |
none |
Disable root guard or loop guard. |
root |
Enable root guard. |
Defaults
Root guard is disabled.
Loop guard is configured according to the spanning-tree loopguard default global configuration command (globally disabled).
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
You can enable root guard or loop guard when the switch is operating in the per-VLAN spanning-tree plus (PVST+), rapid-PVST+, or the multiple spanning-tree (MST) mode.
When root guard is enabled, if spanning-tree calculations cause an interface to be selected as the root port, the interface transitions to the root-inconsistent (blocked) state to prevent the customer’s switch from becoming the root switch or being in the path to the root. The root port provides the best path from the switch to the root switch.
When the no spanning-tree guard or the no spanning-tree guard none command is entered, root guard is disabled for all VLANs on the selected interface. If this interface is in the root-inconsistent (blocked) state, it automatically transitions to the listening state.
Do not enable root guard on interfaces that will be used by the UplinkFast feature. With UplinkFast, the backup interfaces (in the blocked state) replace the root port in the case of a failure. However, if root guard is also enabled, all the backup interfaces used by the UplinkFast feature are placed in the root-inconsistent state (blocked) and prevented from reaching the forwarding state. The UplinkFast feature is not available when the switch is operating in the rapid-PVST+ or MST mode.
Loop guard is most effective when it is configured on the entire switched network. When the switch is operating in PVST+ or rapid-PVST+ mode, loop guard prevents alternate and root ports from becoming designated ports, and spanning tree does not send bridge protocol data units (BPDUs) on root or alternate ports. When the switch is operating in MST mode, BPDUs are not sent on nonboundary interfaces if the interface is blocked by loop guard in all MST instances. On a boundary interface, loop guard blocks the interface in all MST instances.
To disable root guard or loop guard, use the spanning-tree guard none interface configuration command. You cannot enable both root guard and loop guard at the same time.
You can override the setting of the spanning-tree loopguard default global configuration command by using the spanning-tree guard loop interface configuration command.
Examples
This example shows how to enable root guard on all the VLANs associated with the specified port:
Switch(config)# interface gigabitethernet2/0/2
Switch(config-if)# spanning-tree guard root
This example shows how to enable loop guard on all the VLANs associated with the specified port:
Switch(config)# interface gigabitethernet2/0/2
Switch(config-if)# spanning-tree guard loop
You can verify your settings by entering the show running-config privileged EXEC command.
spanning-tree link-type
Use the spanning-tree link-type interface configuration command on the switch stack or on a standalone switch to override the default link-type setting, which is determined by the duplex mode of the interface, and to enable rapid spanning-tree transitions to the forwarding state. Use the no form of this command to return to the default setting.
spanning-tree link-type { point-to-point | shared }
no spanning-tree link-type
Syntax Description
point-to-point |
Specify that the link type of an interface is point-to-point. |
shared |
Specify that the link type of an interface is shared. |
Defaults
The switch derives the link type of an interface from the duplex mode. A full-duplex interface is considered a point-to-point link, and a half-duplex interface is considered a shared link.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
You can override the default setting of the link type by using the spanning-tree link-type command. For example, a half-duplex link can be physically connected point-to-point to a single interface on a remote switch running the Multiple Spanning Tree Protocol (MSTP) or the rapid per-VLAN spanning-tree plus (rapid-PVST+) protocol and be enabled for rapid transitions.
Examples
This example shows how to specify the link type as shared (regardless of the duplex setting) and to prevent rapid transitions to the forwarding state:
Switch(config-if)# spanning-tree link-type shared
You can verify your setting by entering the show spanning-tree mst interface interface-id or the show spanning-tree interface interface-id privileged EXEC command.
Related Commands
|
|
clear spanning-tree detected-protocols |
Restarts the protocol migration process (force the renegotiation with neighboring switches) on all interfaces or on the specified interface. |
show spanning-tree interface interface-id |
Displays spanning-tree state information for the specified interface. |
show spanning-tree mst interface interface-id |
Displays MST information for the specified interface. |
spanning-tree loopguard default
Use the spanning-tree loopguard default global configuration command on the switch stack or on a standalone switch to prevent alternate or root ports from becoming designated ports because of a failure that leads to a unidirectional link. Use the no form of this command to return to the default setting.
spanning-tree loopguard default
no spanning-tree loopguard default
Syntax Description
This command has no arguments or keywords.
Defaults
Loop guard is disabled.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
You can enable the loop guard feature when the switch is operating in the per-VLAN spanning-tree plus (PVST+), rapid-PVST+, or the multiple spanning-tree (MST) mode.
Loop guard is most effective when it is configured on the entire switched network. When the switch is operating in PVST+ or rapid-PVST+ mode, loop guard prevents alternate and root ports from becoming designated ports, and spanning tree does not send bridge protocol data units (BPDUs) on root or alternate ports. When the switch is operating in MST mode, BPDUs are not sent on nonboundary interfaces if the interface is blocked by loop guard in all MST instances. On a boundary interface, loop guard blocks the interface in all MST instances.
Loop guard operates only on interfaces that the spanning tree identifies as point-to-point.
You can override the setting of the spanning-tree loopguard default global configuration command by using the spanning-tree guard loop interface configuration command.
Examples
This example shows how to globally enable loop guard:
Switch(config)# spanning-tree loopguard default
You can verify your settings by entering the show running-config privileged EXEC comm and.
spanning-tree mode
Use the spanning-tree mode global configuration command on the switch stack or on a standalone switch to enable per-VLAN spanning-tree plus (PVST+), rapid PVST+, or multiple spanning tree (MST) on your switch. Use the no form of this command to return to the default setting.
spanning-tree mode { mst | pvst | rapid-pvst }
no spanning-tree mode
Syntax Description
mst |
Enable MST and Rapid Spanning Tree Protocol (RSTP) (based on IEEE 802.1s and IEEE 802.1w). |
pvst |
Enable PVST+ (based on IEEE 802.1D). |
rapid-pvst |
Enable rapid PVST+ (based on IEEE 802.1w). |
Defaults
The default mode is PVST+.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
The switch supports PVST+, rapid PVST+, and MSTP, but only one version can be active at any time: All VLANs run PVST+, all VLANs run rapid PVST+, or all VLANs run MSTP. All stack members run the same version of spanning-tree.
When you enable the MST mode, RSTP is automatically enabled.
Caution
Changing spanning-tree modes can disrupt traffic because all spanning-tree instances are stopped for the previous mode and restarted in the new mode.
Examples
This example shows to enable MST and RSTP on the switch:
Switch(config)# spanning-tree mode mst
This example shows to enable rapid PVST+ on the switch:
Switch(config)# spanning-tree mode rapid-pvst
You can verify your setting by entering the show running-config privileged EXEC command.
spanning-tree mst configuration
Use the spanning-tree mst configuration global configuration command on the switch stack or on a standalone switch to enter multiple spanning-tree (MST) configuration mode through which you configure the MST region. Use the no form of this command to return to the default settings.
spanning-tree mst configuration
no spanning-tree mst configuration
Syntax Description
This command has no arguments or keywords.
Defaults
The default mapping is that all VLANs are mapped to the common and internal spanning-tree (CIST) instance (instance 0).
The default name is an empty string.
The revision number is 0.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
The spanning-tree mst configuration command enables the MST configuration mode. These configuration commands are available:
- abort : exits the MST region configuration mode without applying configuration changes.
- exit : exits the MST region configuration mode and applies all configuration changes.
- instance instance-id vlan vlan-range : maps VLANs to an MST instance. The range for the instance-id is 1 to 4094. The range for vlan-range is 1 to 4094. You can specify a single VLAN identified by VLAN ID number, a range of VLANs separated by a hyphen, or a series of VLANs separated by a comma.
- name name : sets the configuration name. The name string has a maximum length of 32 characters and is case sensitive.
- no : negates the instance, name, and revision commands or sets them to their defaults.
- private-vlan : Though visible in the command-line help strings, this command is not supported.
- revision version : sets the configuration revision number. The range is 0 to 65535.
- show [ current | pending ] : displays the current or pending MST region configuration.
In MST mode, the switch or switch stack supports up to 65 MST instances. The number of VLANs that can be mapped to a particular MST instance is unlimited.
When you map VLANs to an MST instance, the mapping is incremental, and VLANs specified in the command are added to or removed from the VLANs that were previously mapped. To specify a range, use a hyphen; for example, instance 1 vlan 1-63 maps VLANs 1 to 63 to MST instance 1. To specify a series, use a comma; for example, instance 1 vlan 10, 20, 30 maps VLANs 10, 20, and 30 to MST instance 1.
All VLANs that are not explicitly mapped to an MST instance are mapped to the common and internal spanning tree (CIST) instance (instance 0) and cannot be unmapped from the CIST by using the no form of the command.
For two or more switches to be in the same MST region, they must have the same VLAN mapping, the same configuration revision number, and the same name.
Examples
This example shows how to enter MST configuration mode, map VLANs 10 to 20 to MST instance 1, name the region region1, set the configuration revision to 1, display the pending configuration, apply the changes, and return to global configuration mode:
Switch# spanning-tree mst configuration
Switch(config-mst)# instance 1 vlan 10-20
Switch(config-mst)# name region1
Switch(config-mst)# revision 1
Switch(config-mst)# show pending
Pending MST configuration
-------- ---------------------
-------------------------------
This example shows how to add VLANs 1 to 100 to the ones already mapped (if any) to instance 2, to move VLANs 40 to 60 that were previously mapped to instance 2 to the CIST instance, to add VLAN 10 to instance 10, and to remove all the VLANs mapped to instance 2 and map them to the CIST instance:
Switch(config-mst)# instance 2 vlan 1-100
Switch(config-mst)# no instance 2 vlan 40-60
Switch(config-mst)# instance 10 vlan 10
Switch(config-mst)# no instance 2
You can verify your settings by entering the show pending MST configuration command.
spanning-tree mst cost
Use the spanning-tree mst cost interface configuration command on the switch stack or on a standalone switch to set the path cost for multiple spanning-tree (MST) calculations. If a loop occurs, spanning tree considers the path cost when selecting an interface to put in the forwarding state. Use the no form of this command to return to the default setting.
spanning-tree mst instance-id cost cost
no spanning-tree mst instance-id cost
Syntax Description
instance-id |
Range of spanning-tree instances. You can specify a single instance, a range of instances separated by a hyphen, or a series of instances separated by a comma. The range is 0 to 4094. |
cost |
Path cost is 1 to 200000000, with higher values meaning higher costs. |
Defaults
The default path cost is computed from the interface bandwidth setting. These are the IEEE default path cost values:
- 1000 Mb/s—20000
- 100 Mb/s—200000
- 10 Mb/s—2000000
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
When you configure the cost, higher values represent higher costs.
Examples
This example shows how to set a path cost of 250 on a port associated with instances 2 and 4:
Switch(config)# interface gigabitethernet1/0/2
Switch(config-if)# spanning-tree mst 2,4 cost 250
You can verify your settings by entering the show spanning-tree mst interface interface-id privileged EXEC command.
spanning-tree mst forward-time
Use the spanning-tree mst forward-time global configuration command on the switch stack or on a standalone switch to set the forward-delay time for all multiple spanning-tree (MST) instances. The forwarding time specifies how long each of the listening and learning states last before the interface begins forwarding. Use the no form of this command to return to the default setting.
spanning-tree mst forward-time seconds
no spanning-tree mst forward-time
Syntax Description
seconds |
Length of the listening and learning states. The range is 4 to 30 seconds. |
Defaults
The default is 15 seconds.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
Changing the spanning-tree mst forward-time command affects all spanning-tree instances.
Examples
This example shows how to set the spanning-tree forwarding time to 18 seconds for all MST instances:
Switch(config)# spanning-tree mst forward-time 18
You can verify your setting by entering the show spanning-tree mst privileged EXEC command.
spanning-tree mst hello-time
Use the spanning-tree mst hello-time global configuration command on the switch stack or on a standalone switch to set the interval between hello bridge protocol data units (BPDUs) sent by root switch configuration messages. Use the no form of this command to return to the default setting.
spanning-tree mst hello-time seconds
no spanning-tree mst hello-time
Syntax Description
seconds |
Interval between hello BPDUs sent by root switch configuration messages. The range is 1 to 10 seconds. |
Defaults
The default is 2 seconds.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
After you set the spanning-tree mst max-age seconds global configuration command, if a switch does not receive BPDUs from the root switch within the specified interval, the switch recomputes the spanning-tree topology. The max-age setting must be greater than the hello-time setting.
Changing the spanning-tree mst hello-time command affects all spanning-tree instances.
Examples
This example shows how to set the spanning-tree hello time to 3 seconds for all multiple spanning-tree (MST) instances:
Switch(config)# spanning-tree mst hello-time 3
You can verify your setting by entering the show spanning-tree mst privileged EXEC command.
spanning-tree mst max-age
Use the spanning-tree mst max-age global configuration command on the switch stack or on a standalone switch to set the interval between messages that the spanning tree receives from the root switch. If a switch does not receive a bridge protocol data unit (BPDU) message from the root switch within this interval, it recomputes the spanning-tree topology. Use the no form of this command to return to the default setting.
spanning-tree mst max-age seconds
no spanning-tree mst max-age
Syntax Description
seconds |
Interval between messages the spanning tree receives from the root switch. The range is 6 to 40 seconds. |
Defaults
The default is 20 seconds.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
After you set the spanning-tree mst max-age seconds global configuration command, if a switch does not receive BPDUs from the root switch within the specified interval, the switch recomputes the spanning-tree topology. The max-age setting must be greater than the hello-time setting.
Changing the spanning-tree mst max-age command affects all spanning-tree instances.
Examples
This example shows how to set the spanning-tree max-age to 30 seconds for all multiple spanning-tree (MST) instances:
Switch(config)# spanning-tree mst max-age 30
You can verify your setting by entering the show spanning-tree mst privileged EXEC command.
spanning-tree mst max-hops
Use the spanning-tree mst max-hops global configuration command on the switch stack or on a standalone switch to set the number of hops in a region before the bridge protocol data unit (BPDU) is discarded and the information held for an interface is aged. Use the no form of this command to return to the default setting.
spanning-tree mst max-hops hop-count
no spanning-tree mst max-hops
Syntax Description
hop-count |
Number of hops in a region before the BPDU is discarded. The range is 1 to 255 hops. |
Defaults
The default is 20 hops.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
The root switch of the instance always sends a BPDU (or M-record) with a cost of 0 and the hop count set to the maximum value. When a switch receives this BPDU, it decrements the received remaining hop count by one and propagates the decremented count as the remaining hop count in the generated M-records. A switch discards the BPDU and ages the information held for the interface when the count reaches 0.
Changing the spanning-tree mst max-hops command affects all spanning-tree instances.
Examples
This example shows how to set the spanning-tree max-hops to 10 for all multiple spanning-tree (MST) instances:
Switch(config)# spanning-tree mst max-hops 10
You can verify your setting by entering the show spanning-tree mst privileged EXEC command.
spanning-tree mst port-priority
Use the spanning-tree mst port-priority interface configuration command on the switch stack or on a standalone switch to configure an interface priority. If a loop occurs, the Multiple Spanning Tree Protocol (MSTP) can find the interface to put in the forwarding state. Use the no form of this command to return to the default setting.
spanning-tree mst instance-id port-priority priority
no spanning-tree mst instance-id port-priority
Syntax Description
instance-id |
Range of spanning-tree instances. You can specify a single instance, a range of instances separated by a hyphen, or a series of instances separated by a comma. The range is 0 to 4094. |
priority |
The range is 0 to 240 in increments of 16. Valid priority values are 0, 16, 32, 48, 64, 80, 96, 112, 128, 144, 160, 176, 192, 208, 224, and 240. All other values are rejected. The lower the number, the higher the priority. |
Defaults
The default is 128.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
You can assign higher priority values (lower numerical values) to interfaces that you want selected first and lower priority values (higher numerical values) that you want selected last. If all interfaces have the same priority value, the multiple spanning tree (MST) puts the interface with the lowest interface number in the forwarding state and blocks other interfaces.
If your switch is a member of a switch stack, you must use the spanning-tree mst [ instance-id ] cost cost interface configuration command instead of the spanning-tree mst [ instance vlan-id ] port-priority priority interface configuration command to select an interface to put in the forwarding state. Assign lower cost values to interfaces that you want selected first and higher cost values to interfaces that you want selected last.
Examples
This example shows how to increase the likelihood that the interface associated with spanning-tree instances 20 and 22 is placed into the forwarding state if a loop occurs:
Switch(config)# interface gigabitethernet2/0/2
Switch(config-if)# spanning-tree mst 20,22 port-priority 0
You can verify your settings by entering the show spanning-tree mst interface interface-id privileged EXEC command.
spanning-tree mst pre-standard
Use the spanning-tree mst pre-standard interface configuration command to configure a port to send only prestandard bridge protocol data units (BPDUs).
spanning-tree mst pre-standard
no spanning-tree mst pre-standard
Syntax Description
This command has no arguments or keywords.
Command Default
The default state is automatic detection of prestandard neighbors.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
The port can accept both prestandard and standard BPDUs. If the neighbor types are mismatched, only the common and internal spanning tree (CIST) runs on this interface.
Note If a switch port is connected to a switch running prestandard Cisco IOS software, you must use the spanning-tree mst pre-standard interface configuration command on the port. If you do not configure the port to send only prestandard BPDUs, the Multiple STP (MSTP) performance might diminish.
When the port is configured to automatically detect prestandard neighbors, the prestandard flag always appears in the show spanning-tree mst commands.
Examples
This example shows how to configure a port to send only prestandard BPDUs:
Switch(config-if)# spanning-tree mst pre-standard
You can verify your settings by entering the show spanning-tree mst privileged EXEC command.
Related Commands
|
|
show spanning-tree mst instance-id |
Displays multiple spanning-tree (MST) information, including the prestandard flag, for the specified interface. |
spanning-tree mst priority
Use the spanning-tree mst priority global configuration command on the switch stack or on a standalone switch to set the switch priority for the specified spanning-tree instance. Use the no form of this command to return to the default setting.
spanning-tree mst instance-id priority priority
no spanning-tree mst instance-id priority
Syntax Description
instance-id |
Range of spanning-tree instances. You can specify a single instance, a range of instances separated by a hyphen, or a series of instances separated by a comma. The range is 0 to 4094. |
priority |
Set the switch priority for the specified spanning-tree instance. This setting affects the likelihood that the switch is selected as the root switch. A lower value increases the probability that the switch is selected as the root switch. The range is 0 to 61440 in increments of 4096. Valid priority values are 0, 4096, 8192, 12288, 16384, 20480, 24576, 28672, 32768, 36864, 40960, 45056, 49152, 53248, 57344, and 61440. All other values are rejected. |
Defaults
The default is 32768.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Examples
This example shows how to set the spanning-tree priority to 8192 for multiple spanning-tree instances (MST) 20 to 21:
Switch(config)# spanning-tree mst 20-21 priority 8192
You can verify your settings by entering the show spanning-tree mst instance-id privileged EXEC command.
spanning-tree mst root
Use the spanning-tree mst root global configuration command on the switch stack or on a standalone switch to configure the multiple spanning-tree (MST) root switch priority and timers based on the network diameter. Use the no form of this command to return to the default settings.
spanning-tree mst instance-id root { primary | secondary } [ diameter net-diameter
[ hello-time seconds ]]
no spanning-tree mst instance-id root
Syntax Description
instance-id |
Range of spanning-tree instances. You can specify a single instance, a range of instances separated by a hyphen, or a series of instances separated by a comma. The range is 0 to 4094. |
root primary |
Force this switch to be the root switch. |
root secondary |
Set this switch to be the root switch should the primary root switch fail. |
diameter net-diameter |
(Optional) Set the maximum number of switches between any two end stations. The range is 2 to 7. This keyword is available only for MST instance 0. |
hello-time seconds |
(Optional) Set the interval between hello bridge protocol data units (BPDUs) sent by the root switch configuration messages. The range is 1 to 10 seconds. This keyword is available only for MST instance 0. |
Defaults
The primary root switch priority is 24576.
The secondary root switch priority is 28672.
The hello time is 2 seconds.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
Use the spanning-tree mst instance-id root command only on backbone switches.
Whe n you enter the spanning-tree mst instance-id root command, the software tries to set a high enough priority to make this switch the root of the spanning-tree instance. Because of the extended system ID support, the switch sets the switch priority for the instance to 24576 if this value will cause this switch to become the root for the specified instance. If any root switch for the specified instance has a switch priority lower than 24576, the switch sets its own priority to 4096 less than the lowest switch priority. (4096 is the value of the least-significant bit of a 4-bit switch priority value.)
When y ou enter the spanning-tree mst instance-id root secondary command, because of support for the extended system ID, the software changes the switch priority from the default value (32768) to 28672. If the root switch fails, this switch becomes the next root switch (if the other switches in the network use the default switch priority of 32768 and are therefore unlikely to become the root switch).
Examples
This example shows how to configure the switch as the root switch for instance 10 with a network diameter of 4:
Switch(config)# spanning-tree mst 10 root primary diameter 4
This example shows how to configure the switch as the secondary root switch for instance 10 with a network diameter of 4:
Switch(config)# spanning-tree mst 10 root secondary diameter 4
You can verify your settings by entering the show spanning-tree mst instance-id privileged EXEC command.
spanning-tree port-priority
Use the spanning-tree port-priority interface configuration command on the switch stack or on a standalone switch to configure an interface priority. If a loop occurs, spanning tree can find the interface to put in the forwarding state. Use the no form of this command to return to the default setting.
spanning-tree [ vlan vlan-id ] port-priority priority
no spanning-tree [ vlan vlan-id ] port-priority
Syntax Description
vlan vlan-id |
(Optional) VLAN range associated with a spanning-tree instance. You can specify a single VLAN identified by VLAN ID number, a range of VLANs separated by a hyphen, or a series of VLANs separated by a comma. The range is 1 to 4094. |
priority |
Number from 0 to 240, in increments of 16. Valid values are 0, 16, 32, 48, 64, 80, 96, 112, 128, 144, 160, 176, 192, 208, 224, and 240. All other values are rejected. The lower the number, the higher the priority. |
Defaults
The default is 128.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
If the variable vlan-id is omitted, the command applies to the spanning-tree instance associated with VLAN 1.
You can set the priority on a VLAN that has no interfaces assigned to it. The setting takes effect when you assign the interface to the VLAN.
If you configure an interface with both the spanning-tree vlan vlan-id port-priority priority command and the spanning-tree port-priority priority command, the spanning-tree vlan vlan-id port-priority priority command takes effect.
If your switch is a member of a switch stack, you must use the spanning-tree [ vlan vlan-id ] cost cost interface configuration command instead of the spanning-tree [ vlan vlan-id ] port-priority priority interface configuration command to select an interface to put in the forwarding state. Assign lower cost values to interfaces that you want selected first and higher cost values that you want selected last.
Examples
This example shows how to increase the likelihood that a port will be put in the forwarding state if a loop occurs:
Switch(config)# interface gigabitethernet2/0/2
Switch(config-if)# spanning-tree vlan 20 port-priority 0
This example shows how to set the port-priority value on VLANs 20 to 25:
Switch(config-if)# spanning-tree vlan 20-25 port-priority 0
You can verify your settings by entering the show spanning-tree interface interface-id privileged EXEC command.
Related Commands
|
|
show spanning-tree interface interface-id |
Displays spanning-tree information for the specified interface. |
spanning-tree cost |
Sets the path cost for spanning-tree calculations. |
spanning-tree vlan priority |
Sets the switch priority for the specified spanning-tree instance. |
spanning-tree portfast (global configuration)
Use the spanning-tree portfast global configuration command on the switch stack or on a standalone switch to globally enable bridge protocol data unit (BPDU) filtering on Port Fast-enabled interfaces, the BPDU guard feature on Port Fast-enabled interfaces, or the Port Fast feature on all nontrunking interfaces. The BPDU filtering feature prevents the switch interface from sending or receiving BPDUs. The BPDU guard feature puts Port Fast-enabled interfaces that receive BPDUs in an error-disabled state. Use the no form of this command to return to the default settings.
spanning-tree portfast { bpdufilter default | bpduguard default | default }
no spanning-tree portfast { bpdufilter default | bpduguard default | default }
Syntax Description
bpdufilter default |
Globally enable BPDU filtering on Port Fast-enabled interfaces and prevent the switch interface connected to end stations from sending or receiving BPDUs. |
bpduguard default |
Globally enable the BPDU guard feature on Port Fast-enabled interfaces and place the interfaces that receive BPDUs in an error-disabled state. |
default |
Globally enable the Port Fast feature on all nontrunking interfaces. When the Port Fast feature is enabled, the interface changes directly from a blocking state to a forwarding state without making the intermediate spanning-tree state changes. |
Defaults
The BPDU filtering, the BPDU guard, and the Port Fast features are disabled on all interfaces unless they are individually configured.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
You can enable these features when the switch is operating in the per-VLAN spanning-tree plus (PVST+) rapid-PVST+, or the multiple spanning-tree (MST) mode.
Use the spanning-tree portfast bpdufilter default global configuration command to globally enable BPDU filtering on interfaces that are Port Fast-enabled (the interfaces are in a Port Fast-operational state). The interfaces still send a few BPDUs at link-up before the switch begins to filter outbound BPDUs. You should globally enable BPDU filtering on a switch so that hosts connected to switch interfaces do not receive BPDUs. If a BPDU is received on a Port Fast-enabled interface, the interface loses its Port Fast-operational status and BPDU filtering is disabled.
You can override the spanning-tree portfast bpdufilter default global configuration command by using the spanning-tree bdpufilter interface configuration command.
Caution
Enabling BPDU filtering on an interface is the same as disabling spanning tree on it and can result in spanning-tree loops.
Use the spanning-tree portfast bpduguard default global configuration command to globally enable BPDU guard on interfaces that are in a Port Fast-operational state. In a valid configuration, Port Fast-enabled interfaces do not receive BPDUs. Receiving a BPDU on a Port Fast-enabled interface signals an invalid configuration, such as the connection of an unauthorized device, and the BPDU guard feature puts the interface in the error-disabled state. The BPDU guard feature provides a secure response to invalid configurations because you must manually put the interface back in service. Use the BPDU guard feature in a service-provider network to prevent an access port from participating in the spanning tree.
You can override the spanning-tree portfast bpduguard default global configuration command by using the spanning-tree bdpuguard interface configuration command.
Use the spanning-tree portfast default global configuration command to globally enable the Port Fast feature on all nontrunking interfaces. Configure Port Fast only on interfaces that connect to end stations; otherwise, an accidental topology loop could cause a data packet loop and disrupt switch and network operation. A Port Fast-enabled interface moves directly to the spanning-tree forwarding state when linkup occurs without waiting for the standard forward-delay time.
You can override the spanning-tree portfast default global configuration command by using the spanning-tree portfast interface configuration command. You can use the no spanning-tree portfast default global configuration command to disable Port Fast on all interfaces unless they are individually configured with the spanning-tree portfast interface configuration command.
Examples
This example shows how to globally enable the BPDU filtering feature:
Switch(config)# spanning-tree portfast bpdufilter default
This example shows how to globally enable the BPDU guard feature:
Switch(config)# spanning-tree portfast bpduguard default
This example shows how to globally enable the Port Fast feature on all nontrunking interfaces:
Switch(config)# spanning-tree portfast default
You can verify your settings by entering the show running-config privileged EXEC command.
spanning-tree portfast (interface configuration)
Use the spanning-tree portfast interface configuration command on the switch stack or on a standalone switch to enable the Port Fast feature on an interface in all its associated VLANs. When the Port Fast feature is enabled, the interface changes directly from a blocking state to a forwarding state without making the intermediate spanning-tree state changes. Use the no form of this command to return to the default setting.
spanning-tree portfast [ disable | trunk ]
no spanning-tree portfast
Syntax Description
disable |
(Optional) Disable the Port Fast feature on the specified interface. |
trunk |
(Optional) Enable the Port Fast feature on a trunking interface. |
Defaults
The Port Fast feature is disabled on all interfaces; however, it is automatically enabled on dynamic-access ports.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
Use this feature only on interfaces that connect to end stations; otherwise, an accidental topology loop could cause a data packet loop and disrupt switch and network operation.
To enable Port Fast on trunk ports, you must use the spanning-tree portfast trunk interface configuration command. The spanning-tree portfast command is not supported on trunk ports.
You can enable this feature when the switch is operating in the per-VLAN spanning-tree plus (PVST+), rapid-PVST+, or the multiple spanning-tree (MST) mode.
This feature affects all VLANs on the interface.
An interface with the Port Fast feature enabled is moved directly to the spanning-tree forwarding state without the standard forward-time delay.
You can use the spanning-tree portfast default global configuration command to globally enable the Port Fast feature on all nontrunking interfaces. However, the spanning-tree portfast interface configuration command can override the global setting.
If you configure the spanning-tree portfast default global configuration command, you can disable Port Fast on an interface that is not a trunk interface by using the spanning-tree portfast disable interface configuration command.
Examples
This example shows how to enable the Port Fast feature on a port:
Switch(config)# interface gigabitethernet2/0/2
Switch(config-if)# spanning-tree portfast
You can verify your settings by entering the show running-config privileged EXEC command.
spanning-tree transmit hold-count
Use the spanning-tree transmit hold-count global configuration command to configure the number of bridge protocol data units (BPDUs) sent every second. Use the no form of this command to return to the default setting.
spanning-tree transmit hold-count [ value ]
no spanning-tree transmit hold-count [ value ]
Syntax Description
value |
(Optional) Number of BPDUs sent every second. The range is 1 to 20. |
Defaults
The default is 6.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
Increasing the transmit hold-count value can have a significant impact on CPU utilization when the switch is in rapid-per-VLAN spanning-tree plus (rapid-PVST+) mode. Decreasing this value might slow down convergence. We recommend using the default setting.
Examples
This example shows how to set the transmit hold count to 8:
Switch(config)# spanning-tree transmit hold-count 8
You can verify your setting by entering the show spanning-tree mst privileged EXEC command.
Related Commands
|
|
show spanning-tree mst |
Displays the multiple spanning-tree (MST) region configuration and status, including the transmit hold count. |
spanning-tree uplinkfast
Use the spanning-tree uplinkfast global configuration command on the switch stack or on a standalone switch to accelerate the choice of a new root port when a link or switch fails or when the spanning tree reconfigures itself. Use the no form of this command to return to the default setting.
spanning-tree uplinkfast [ max-update-rate pkts-per-second ]
no spanning-tree uplinkfast [ max-update-rate ]
Syntax Description
max-update-rate pkts-per-second |
(Optional) The number of packets per second at which update packets are sent. The range is 0 to 32000. |
Defaults
UplinkFast is disabled.
The update rate is 150 packets per second.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
Use this command only on access switches.
You can configure the UplinkFast feature for rapid PVST+ or for multiple spanning-tree (MST) mode, but the feature remains disabled (inactive) until you change the spanning-tree mode to PVST+.
When you enable UplinkFast, it is enabled for the entire switch and cannot be enabled for individual VLANs.
On Catalyst 3750-X switches, when you enable or disable UplinkFast, cross-stack UplinkFast (CSUF) also is automatically enabled or disabled on all nonstack port interfaces. CSUF accelerates the choice of a new root port when a link or switch fails or when spanning tree reconfigures itself.
When UplinkFast is enabled, the switch priority of all VLANs is set to 49152. If you change the path cost to a value less than 3000 and you enable UplinkFast or UplinkFast is already enabled, the path cost of all interfaces and VLAN trunks is increased by 3000 (if you change the path cost to 3000 or above, the path cost is not altered). The changes to the switch priority and the path cost reduces the chance that a switch will become the root switch.
When UplinkFast is disabled, the switch priorities of all VLANs and path costs of all interfaces are set to default values if you did not modify them from their defaults.
When spanning tree detects that the root port has failed, UplinkFast immediately changes to an alternate root port, changing the new root port directly to forwarding state. During this time, a topology change notification is sent.
Do not enable the root guard on interfaces that will be used by the UplinkFast feature. With UplinkFast, the backup interfaces (in the blocked state) replace the root port in the case of a failure. However, if root guard is also enabled, all the backup interfaces used by the UplinkFast feature are placed in the root-inconsistent state (blocked) and prevented from reaching the forwarding state.
If you set the max-update-rate to 0, station-learning frames are not generated, so the spanning-tree topology converges more slowly after a loss of connectivity.
Examples
This example shows how to enable UplinkFast:
Switch(config)# spanning-tree uplinkfast
You can verify your setting by entering the show spanning-tree summary privileged EXEC command.
spanning-tree vlan
Use the spanning-tree vlan global configuration command on the switch stack or on a standalone switch to configure spanning tree on a per-VLAN basis. Use the no form of this command to return to the default setting.
spanning-tree vlan vlan-id [ forward-time seconds | hello-time seconds | max-age seconds |
priority priority | root { primary | secondary } [ diameter net-diameter
[ hello-time seconds ]]]
no spanning-tree vlan vlan-id [ forward-time | hello-time | max-age | priority | root ]
Syntax Description
vlan-id |
VLAN range associated with a spanning-tree instance. You can specify a single VLAN identified by VLAN ID number, a range of VLANs separated by a hyphen, or a series of VLANs separated by a comma. The range is 1 to 4094. |
forward-time seconds |
(Optional) Set the forward-delay time for the specified spanning-tree instance. The forwarding time specifies how long each of the listening and learning states last before the interface begins forwarding. The range is 4 to 30 seconds. |
hello-time seconds |
(Optional) Set the interval between hello bridge protocol data units (BPDUs) sent by the root switch configuration messages. The range is 1 to 10 seconds. |
max-age seconds |
(Optional) Set the interval between messages the spanning tree receives from the root switch. If a switch does not receive a BPDU message from the root switch within this interval, it recomputes the spanning-tree topology. The range is 6 to 40 seconds. |
priority priority |
(Optional) Set the switch priority for the specified spanning-tree instance. This setting affects the likelihood that the switch is selected as the root switch. A lower value increases the probability that the switch is selected as the root switch. The range is 0 to 61440 in increments of 4096. Valid priority values are 4096, 8192, 12288, 16384, 20480, 24576, 28672, 32768, 36864, 40960, 45056, 49152, 53248, 57344, and 61440. All other values are rejected. |
root primary |
(Optional) Force this switch to be the root switch. |
root secondary |
(Optional) Set this switch to be the root switch should the primary root switch fail. |
diameter net-diameter |
(Optional) Set the maximum number of switches between any two end stations. The range is 2 to 7. |
Defaults
Spanning tree is enabled on all VLANs.
The forward-delay time is 15 seconds.
The hello time is 2 seconds.
The max-age is 20 seconds.
The primary root switch priority is 24576.
The secondary root switch priority is 28672.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
Disabling the STP causes the VLAN to stop participating in the spanning-tree topology. Interfaces that are administratively down remain down. Received BPDUs are forwarded like other multicast frames. The VLAN does not detect and prevent loops when STP is disabled.
You can disable the STP on a VLAN that is not currently active and verify the change by using the show running-config or the show spanning-tree vlan vlan-id privileged EXEC command. The setting takes effect when the VLAN is activated.
When disabling or re-enabling the STP, you can specify a range of VLANs that you want to disable or enable.
When a VLAN is disabled and then enabled, all assigned VLANs continue to be its members. However, all spanning-tree bridge parameters are returned to their previous settings (the last setting before the VLAN was disabled).
You can enable spanning-tree options on a VLAN that has no interfaces assigned to it. The setting takes effect when you assign interfaces to it.
When setting the max-age seconds, if a switch does not receive BPDUs from the root switch within the specified interval, it recomputes the spanning-tree topology. The max-age setting must be greater than the hello-time setting.
The spanning-tree vlan vlan-id root command should be used only on backbone switches.
When you enter the spanning-tree vlan vlan-id root command, the software checks the switch priority of the current root switch for each VLAN. Because of the extended system ID support, the switch sets the switch priority for the specified VLAN to 24576 if this value will cause this switch to become the root for the specified VLAN. If any root switch for the specified VLAN has a switch priority lower than 24576, the switch sets its own priority for the specified VLAN to 4096 less than the lowest switch priority. (4096 is the value of the least-significant bit of a 4-bit switch priority value.)
When you enter the spanning-tree vlan vlan-id root secondary command, because of support for the extended system ID, the software changes the switch priority from the default value (32768) to 28672. If the root switch should fail, this switch becomes the next root switch (if the other switches in the network use the default switch priority of 32768, and therefore, are unlikely to become the root switch).
Examples
This example shows how to disable the STP on VLAN 5:
Switch(config)# no spanning-tree vlan 5
You can verify your setting by entering the show spanning-tree privileged EXEC command. In this instance, VLAN 5 does not appear in the list.
This example shows how to set the spanning-tree forwarding time to 18 seconds for VLANs 20 and 25:
Switch(config)# spanning-tree vlan 20,25 forward-time 18
This example shows how to set the spanning-tree hello-delay time to 3 seconds for VLANs 20 to 24:
Switch(config)# spanning-tree vlan 20-24 hello-time 3
This example shows how to set spanning-tree max-age to 30 seconds for VLAN 20:
Switch(config)# spanning-tree vlan 20 max-age 30
This example shows how to reset the max-age parameter to the default value for spanning-tree instance 100 and 105 to 108:
Switch(config)# no spanning-tree vlan 100, 105-108 max-age
This example shows how to set the spanning-tree priority to 8192 for VLAN 20:
Switch(config)# spanning-tree vlan 20 priority 8192
This example shows how to configure the switch as the root switch for VLAN 10 with a network diameter of 4:
Switch(config)# spanning-tree vlan 10 root primary diameter 4
This example shows how to configure the switch as the secondary root switch for VLAN 10 with a network diameter of 4:
Switch(config)# spanning-tree vlan 10 root secondary diameter 4
You can verify your settings by entering the show spanning-tree vlan vlan-id privileged EXEC command.
speed
Use the speed interface configuration command on the switch stack or on a standalone switch to specify the speed of a 10/100 Mb/s or 10/100/1000 Mb/s port. Use the no or default form of this command to return the port to its default value.
speed { 10 | 100 | 1000 | auto [ 10 | 100 | 1000 ] | nonegotiate }
no speed
Syntax Description
10 |
Port runs at 10 Mb/s. |
100 |
Port runs at 100 Mb/s. |
1000 |
Port runs at 1000 Mb/s. This option is valid and visible only on 10/100/1000 Mb/s-ports. |
auto |
Port automatically detects the speed it should run at based on the port at the other end of the link. If you use the 10, 100, or 1000 keywords with the auto keyword, the port only autonegotiates at the specified speeds. |
nonegotiate |
Autonegotiation is disabled, and the port runs at 1000 Mb/s. |
Defaults
The default is auto.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
You cannot configure speed on the 10-Gigabit Ethernet ports.
Except for the 1000BASE-T small form-factor pluggable (SFP) modules, you can configure the speed to not negotiate (nonegotiate ) when an SFP module port is connected to a device that does not support autonegotiation.
If the speed is set to auto, the switch negotiates with the device at the other end of the link for the speed setting and then forces the speed setting to the negotiated value. The duplex setting remains as configured on each end of the link, which could result in a duplex setting mismatch.
If both ends of the line support autonegotiation, we highly recommend the default autonegotiation settings. If one interface supports autonegotiation and the other end does not, do use the auto setting on the supported side, but set the duplex and speed on the other side.
Caution
Changing the interface speed and duplex mode configuration might shut down and re-enable the interface during the reconfiguration.
For guidelines on setting the switch speed and duplex parameters, see the “Configuring Interface Characteristics” chapter in the software configuration guide for this release.
Examples
This example shows how to set speed on a port to 100 Mb/s:
Switch(config)# interface gigabitethernet1/0/117
Switch(config-if)# speed 100
This example shows how to set a port to autonegotiate at only 10 Mb/s:
Switch(config)# interface gigabitethernet1/0/118
Switch(config-if)# speed auto 10
This example shows how to set a port to autonegotiate at only 10 or 100 Mb/s:
Switch(config)# interface gigabitethernet1/0/117
Switch(config-if)# speed auto 10 100
You can verify your settings by entering the show interfaces privileged EXEC command.
Related Commands
|
|
duplex |
Specifies the duplex mode of operation. |
show interfaces |
Displays the statistical information specific to all interfaces or to a specific interface. |
srr-queue bandwidth limit
Use the srr-queue bandwidth limit interface configuration command on the switch stack or on a standalone switch to limit the maximum output on a port. Use the no form of this command to return to the default setting.
srr-queue bandwidth limit weight1
no srr-queue bandwidth limit
Syntax Description
weight1 |
Percentage of the port speed to which the port should be limited. The range is 10 to 90. |
Defaults
The port is not rate limited and is set to 100 percent.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
If you configure this command to 80 percent, the port is idle 20 percent of the time. The line rate drops to 80 percent of the connected speed. These values are not exact because the hardware adjusts the line rate in increments of six.
Note The egress queue default settings are suitable for most situations. You should change them only when you have a thorough understanding of the egress queues and if these settings do not meet your quality of service (QoS) solution.
Examples
This example shows how to limit a port to 800 Mb/s:
Switch(config)# interface gigabitethernet2/0/1
Switch(config-if)# srr-queue bandwidth limit 80
You can verify your settings by entering the show mls qos interface [ interface-id ] queueing privileged EXEC command.
srr-queue bandwidth shape
Use the srr-queue bandwidth shape interface configuration command on the switch stack or on a standalone switch to assign the shaped weights and to enable bandwidth shaping on the four egress queues mapped to a port. Use the no form of this command to return to the default setting.
srr-queue bandwidth shape weight1 weight2 weight3 weight4
no srr-queue bandwidth shape
Syntax Description
weight1 weight2 weight3 weight4 |
Specify the weights to specify the percentage of the port that is shaped. The inverse ratio (1/ weight) specifies the shaping bandwidth for this queue. Separate each value with a space. The range is 0 to 65535. |
Defaults
Weight1 is set to 25. Weight2, weight3, and weight4 are set to 0, and these queues are in shared mode.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
In shaped mode, the queues are guaranteed a percentage of the bandwidth, and they are rate-limited to that amount. Shaped traffic does not use more than the allocated bandwidth even if the link is idle. Use shaping to smooth bursty traffic or to provide a smoother output over time.
The shaped mode overrides the shared mode.
If you configure a shaped queue weight to 0 by using the srr-queue bandwidth shape interface configuration command, this queue participates in shared mode. The weight specified with the srr-queue bandwidth shape command is ignored, and the weights specified with the srr-queue bandwidth share interface configuration command for a queue come into effect.
When configuring queues for the same port for both shaping and sharing, make sure that you configure the lowest numbered queue for shaping.
Note The egress queue default settings are suitable for most situations. You should change them only when you have a thorough understanding of the egress queues and if these settings do not meet your QoS solution.
Examples
This example shows how to configure the queues for the same port for both shaping and sharing. Because the weight ratios for queues 2, 3, and 4 are set to 0, these queues operate in shared mode. The bandwidth weight for queue 1 is 1/8, which is 12.5 percent. Queue 1 is guaranteed this bandwidth and limited to it; it does not extend its slot to the other queues even if the other queues have no traffic and are idle. Queues 2, 3, and 4 are in shared mode, and the setting for queue 1 is ignored. The bandwidth ratio allocated for the queues in shared mode is 4/(4+4+4), which is 33 percent:
Switch(config)# interface gigabitethernet2/0/1
Switch(config-if)# srr-queue bandwidth shape 8 0 0 0
Switch(config-if)# srr-queue bandwidth share 4 4 4 4
You can verify your settings by entering the show mls qos interface [ interface-id ] queueing privileged EXEC command.
srr-queue bandwidth share
Use the srr-queue bandwidth share interface configuration command on the switch stack or on a standalone switch to assign the shared weights and to enable bandwidth sharing on the four egress queues mapped to a port. The ratio of the weights is the ratio of frequency in which the shaped round robin (SRR) scheduler dequeues packets from each queue. Use the no form of this command to return to the default setting.
srr-queue bandwidth share weight1 weight2 weight3 weight4
no srr-queue bandwidth share
Syntax Description
weight1 weight2 weight3 weight4 |
The ratios of weight1, weight2, weight3, and weight4 specify the ratio of the frequency in which the SRR scheduler dequeues packets. Separate each value with a space. The range is 1 to 255. |
Defaults
Weight1, weight2, weight3, and weight4 are 25 (1/4 of the bandwidth is allocated to each queue).
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
The absolute value of each weight is meaningless, and only the ratio of parameters is used.
In shared mode, the queues share the bandwidth among them according to the configured weights. The bandwidth is guaranteed at this level but not limited to it. For example, if a queue empties and does not require a share of the link, the remaining queues can expand into the unused bandwidth and share it among themselves.
If you configure a shaped queue weight to 0 by using the srr-queue bandwidth shape interface configuration command, this queue participates in SRR shared mode. The weight specified with the srr-queue bandwidth shape command is ignored, and the weights specified with the srr-queue bandwidth share interface configuration command for a queue take effect.
When configuring queues for the same port for both shaping and sharing, make sure that you configure the lowest numbered queue for shaping.
Note The egress queue default settings are suitable for most situations. You should change them only when you have a thorough understanding of the egress queues and if these settings do not meet your QoS solution.
Examples
This example shows how to configure the weight ratio of the SRR scheduler running on an egress port. Four queues are used. The bandwidth ratio allocated for each queue in shared mode is 1/(1+2+3+4), 2/(1+2+3+4), 3/(1+2+3+4), and 4/(1+2+3+4), which is 10 percent, 20 percent, 30 percent, and 40 percent for queues 1, 2, 3, and 4. This means that queue 4 has four times the bandwidth of queue 1, twice the bandwidth of queue 2, and one-and-a-third times the bandwidth of queue 3.
Switch(config)# interface gigabitethernet2/0/1
Switch(config-if)# srr-queue bandwidth share 1 2 3 4
You can verify your settings by entering the show mls qos interface [ interface-id ] queueing privileged EXEC command.
stack-mac persistent timer
Use the stack-mac persistent timer global configuration command on the switch stack or on a standalone switch to enable the persistent MAC address feature. When this feature is enabled, if the stack master changes, the stack MAC address does not change for approximately four minutes, for an indefinite time period, or for a configured time value. If the switch that was previously the stack master rejoins the stack during this period, the stack continues to use its MAC address as the stack MAC address, even if the switch is now a stack member. Use the no form of this command to return to the default setting.
stack-mac persistent timer [ 0 | time-value ]
no stack-mac persistent timer
Note This command is supported only on Catalyst 3750-X switches.
Syntax Description
0 |
(Optional) Enter to continue using the MAC address of the current stack master after a new stack master takes over. |
time-value |
(Optional) Set the time period in minutes before the stack MAC address changes to that of the new stack master. The range is 1 to 60 minutes. When no value is entered, the default is 4 minutes. We recommend that you configure an explicit value for this command. |
Defaults
Persistent MAC address is disabled. The MAC address of the stack is always that of the stack master.
When the command is entered with no value, the default time before the MAC address changes is 4 minutes. We recommend that you configure an explicit value for this command.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
The MAC address of the switch stack is determined by the MAC address of the stack master. In the default state (persistent MAC address disabled), if a new switch becomes stack master, the stack MAC address changes to the MAC address of the new stack master.
When persistent MAC address is enabled, the stack MAC address does not change for approximately four minutes. During that time, if the previous stack master rejoins the stack as a stack member, the stack retains its MAC address for as long as the switch that has that MAC address is in the stack. If the previous stack master does not rejoin the stack, the switch stack takes the MAC address of the new stack master as the stack MAC address.
If the whole stack reloads, when it comes back up, the MAC address of the stack master is the stack MAC address.
Examples
This examples shows how to enable persistent MAC address:
Switch(config)# stack-mac persistent timer
You can verify your settings by entering the show running-config privileged EXEC command. If enabled, stack-mac persistent timer is shown in the output.
stack-power
To configure StackPower parameters for the power stack or for a switch in the power stack, use the stack power global configuration command. To return to the default setting, use the no form of the command,
stack-power { stack power stack n ame | switch switch-number }
no stack-power { stack-id name | switch switch-number }
Note This command is available only on Catalyst 3750-X switch stacks running the IP base or IP services image.
Syntax Description
stack power stack n ame |
Enter the power stack name. The name can be up to 31 characters. Entering these keywords followed by a carriage return puts you in power stack configuration mode. |
switch switch-number |
Enter the switch number in the stack (1 to 4) to enter switch stack-power configuration mode for the switch. |
Defaults
There is no default.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
When you enter the stack-power stack power stack name command, you enter power stack configuration mode, and these commands are available:
- default : returns a command to its default setting.
- exit : exits ARP access-list configuration mode.
- mode : sets the power mode for the power stack. See the mode command.
- no : negates a command or returns to default settings.
If you enter the stack-power switch switch-number command with a switch number that is not participating in stack power, you receive an error message.
When you enter the stack-power switch switch-number command with the number of a switch participating in stack power, you enter switch stack power configuration mode, and these commands are available:
- default : returns a command to its default setting.
- exit : exits switch stack power configuration mode.
- no : negates a command or returns to default settings.
- power-priority : sets the power priority for the switch and the switch ports. See the power-priority command.
- stack-id name : enter the name of the power stack to which the switch belongs. If you do not enter the power stack-ID, the switch does not inherit the stack parameters. The name can be up to 31 characters.
- standalone : Forces the switch to operate in standalone power mode. This mode shuts down both stack power ports.
Examples
This example removes switch 2, which is connected to the power stack, from the power pool and shutting down both power ports.
Switch(config)# stack-power switch 2
Switch(config-switch-stackpower)# standalone
Switch(config-switch-stackpower)# exit
Related Commands
|
|
power inline |
Configures the power management mode for the specified PoE port or for all PoE ports. |
power-priority |
Sets the power priority for the switch and the switch ports. |
show stack-power |
Displays parameters of the power stack. |
storm-control
Use the storm-control interface configuration command on the switch stack or on a standalone switch to enable broadcast, multicast, or unicast storm control and to set threshold levels on an interface. Use the no form of this command to return to the default setting.
storm-control {{ broadcast | multicast | unicast } level { level [ level-low ] | bps bps [ bps-low ] | pps pps [ pps-low ]}} | { action { shutdown | trap }}
no storm-control {{ broadcast | multicast | unicast } level } | { action { shutdown | trap }}
Syntax Description
broadcast |
Enable broadcast storm control on the interface. |
multicast |
Enable multicast storm control on the interface. |
unicast |
Enable unicast storm control on the interface. |
level level [ level-low ] |
Specify the rising and falling suppression levels as a percentage of total bandwidth of the port.
- level — Rising suppression level, up to two decimal places. The range is 0.00 to 100.00. B lock the flooding of storm packets when the value specified for level is reached.
- level-low — (Optional) Falling suppression level, up to two decimal places. The range is 0.00 to 100.00. This value must be less than or equal to the rising suppression value. If you do not configure a falling suppression level, it is set to the rising suppression level.
|
level bps bps [ bps-low ] |
Specify the rising and falling suppression levels as a rate in bits per second at which traffic is received on the port.
- bps — Rising suppression level, up to 1 decimal place. The range is 0.0 to 10000000000.0. B lock the flooding of storm packets when the value specified for bps is reached.
- bps-low — (Optional) Falling suppression level, up to 1 decimal place. The range is 0.0 to 10000000000.0. This value must be equal to or less than the rising suppression value.
You can use metric suffixes such as k, m, and g for large number thresholds. |
level pps pps [ pps-low ] |
Specify the rising and falling suppression levels as a rate in packets per second at which traffic is received on the port.
- pps — Rising suppression level, up to 1 decimal place. The range is 0.0 to 10000000000.0. Bl ock the flooding of storm packets when the value specified for pps is reached.
- pps-low — (Optional) Falling suppression level, up to 1 decimal place. The range is 0.0 to 10000000000.0. This value must be equal to or less than the rising suppression value.
You can use metric suffixes such as k, m, and g for large number thresholds. |
action { shutdown | trap } |
Action taken when a storm occurs on a port. The default action is to filter traffic and to not send an Simple Network Management Protocol (SNMP) trap. The keywords have these meanings:
- shutdown —Disables the port during a storm.
- trap —Sends an SNMP trap when a storm occurs.
|
Defaults
Broadcast, multicast, and unicast storm control are disabled.
The default action is to filter traffic and to not send an SNMP trap.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
The storm-control suppression level can be entered as a percentage of total bandwidth of the port, as a rate in packets per second at which traffic is received, or as a rate in bits per second at which traffic is received.
When specified as a percentage of total bandwidth, a suppression value of 100 percent means that no limit is placed on the specified traffic type. A value of level 0 0 means that all broadcast, multicast, or unicast traffic on that port is blocked. Storm control is enabled only when the rising suppression level is less than 100 percent. If no other storm-control configuration is specified, the default action is to filter the traffic causing the storm and to send no SNMP traps.
Note When the storm control threshold for multicast traffic is reached, all multicast traffic except control traffic, such as bridge protocol data unit (BDPU) and Cisco Discovery Protocol (CDP) frames, are blocked. However, the switch does not differentiate between routing updates, such as Open Shortest Path First (OSPF) and regular multicast data traffic, so both types of traffic are blocked.
The trap and shutdown options are independent of each other.
If you configure the action to be taken as shutdown (the port is error-disabled during a storm) when a packet storm is detected, you must use the no shutdown interface configuration command to bring the interface out of this state. If you do not specify the shutdown action, specify the action as trap (the switch generates a trap when a storm is detected).
When a storm occurs and the action is to filter traffic, if the falling suppression level is not specified, the switch blocks all traffic until the traffic rate drops below the rising suppression level. If the falling suppression level is specified, the switch blocks traffic until the traffic rate drops below this level.
Note Storm control is supported on physical interfaces. You can also configure storm control on an EtherChannel. When storm control is configured on an EtherChannel, the storm control settings propagate to the EtherChannel physical interfaces.
When a broadcast storm occurs and the action is to filter traffic, the switch blocks only broadcast traffic.
For more information, see the software configuration guide for this release.
Examples
This example shows how to enable broadcast storm control with a 75.5-percent rising suppression level:
Switch(config-if)# storm-control broadcast level 75.5
This example shows how to enable unicast storm control on a port with a 87-percent rising suppression level and a 65-percent falling suppression level:
Switch(config-if)# storm-control unicast level 87 65
This example shows how to enable multicast storm control on a port with a 2000-packets-per-second rising suppression level and a 1000-packets-per-second falling suppression level:
Switch(config-if)# storm-control multicast level pps 2k 1k
This example shows how to enable the shutdown action on a port:
Switch(config-if)# storm-control action shutdown
You can verify your settings by entering the show storm-control privileged EXEC command.
Related Commands
|
|
show storm-control |
Displays broadcast, multicast, or unicast storm control settings on all interfaces or on a specified interface. |
switch
Use the switch privileged EXEC on a stack member to disable or enable the specified stack port on the member.
switch stack-member-number stack port port-number { disable | enable }
Syntax Description
stack-member-number |
Specify the current stack member number. The range is 1 to 9. |
stack port port-number |
Specify the stack port on the member. The range is 1 to 2. |
disable |
Disable the specified port. |
enable |
Enable the specified port. |
Defaults
The stack port is enabled.
Command Modes
Privileged EXEC
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
A stack is in the full-ring state when all members are connected through the stack ports and are in the ready state.
The stack is in the partial-ring state when
- All members are connected through their stack ports, but some are not in the ready state.
- Some members are not connected through the stack ports.
Note Be careful when using the switch stack-member-number stack port port-number disable command. When you disable the stack port, the stack operates at half or full bandwidth.
If you enter the switch stack-member-number stack port port-number disable privileged EXEC command and
- The stack is in the full-ring state, you can disable only one stack port. This message appears:
Enabling/disabling a stack port may cause undesired stack changes. Continue?[confirm]
- The stack is in the partial-ring state, you cannot disable the port. This message appears:
Disabling stack port not allowed with current stack configuration.
Examples
This example shows how to disable stack port 2 on member 4:
Switch# switch 4 stack port 2 disable
Related Commands
|
|
show switch |
Displays information about the switch stack and the stack members. |
switch priority
Use the switch priority global configuration command on the stack master to change the stack member priority value.
switch stack-member-number priority new-priority-value
Note This command is supported only on Catalyst 3750-X switches.
Syntax Description
stack-member-number |
Specify the current stack member number. The range is 1 to 9. |
priority new-priority-value |
Specify the new stack member priority value. The range is 1 to 15. |
Defaults
The default priority value is 1.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
The new priority value is a factor during a stack-master re-election. Therefore, changing the priority value does not change the stack master immediately.
Examples
This example shows how to change the priority value of stack member 6 to 9:
Switch(config)# switch 6 priority 9
Changing the Switch Priority of Switch Number 6 to 9
Do you want to continue?[confirm]
Related Commands
|
|
reload |
Reloads the stack member and puts a configuration change into effect. |
session |
Accesses a specific stack member. |
switch renumber |
Changes the stack member number. |
show switch |
Displays information about the switch stack and its stack members. |
switch provision
Use the switch provision global configuration command on the stack master to provision (to supply a configuration to) a new switch before it joins the switch stack. Use the no form of this command to delete all configuration information associated with the removed switch (a stack member that has left the stack).
switch stack-member-number provision type
no switch stack-member-number provision
Note This command is supported only on Catalyst 3750-X switches.
Syntax Description
stack-member-number |
Specify the stack member number. The range is 1 to 9. |
provision type |
Specify the switch type of the new switch before it joins the stack. For type, enter the model number of a supported switch that is listed in the command-line help strings. |
Defaults
The switch is not provisioned.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
To avoid receiving an error message, you must remove the specified switch from the switch stack before using the no form of this command to delete a provisioned configuration.
To change the switch type, you must also remove the specified switch from the switch stack. You can change the stack member number of a provisioned switch that is physically present in the switch stack if you do not also change the switch type.
If the switch type of the provisioned switch does not match the switch type in the provisioned configuration on the stack, the switch stack applies the default configuration to the provisioned switch and adds it to the stack. The switch stack displays a message when it applies the default configuration.
Provisioned information appears in the running configuration of the switch stack. When you enter the copy running-config startup-config privileged EXEC command, the provisioned configuration is saved in the startup configuration file of the switch stack.
Caution
When you use this command, memory is allocated for the provisioned configuration. When a new switch type is configured, the previously allocated memory is not fully released. Therefore, do not use this command more than approximately 200 times, or the switch will run out of memory and unexpected behavior will result.
Examples
This example shows how to provision a switch with a stack member number of 2 for the switch stack. The show running-config command output shows the interfaces associated with the provisioned switch:
Switch(config)# switch 2 provision WS-xxxx
Switch# show running-config | include switch 2
interface GigabitEthernet2/0/1
interface GigabitEthernet2/0/2
interface GigabitEthernet2/0/3
You also can enter the show switch user EXEC command to display the provisioning status of the switch stack.
This example shows how to delete all configuration information about a stack member 5 when the switch is removed from the stack:
Switch(config)# no switch 5 provision
You can verify that the provisioned switch is added to or removed from the running configuration by entering the show running-config privileged EXEC command.
switch renumber
Use the switch renumber global configuration command on the stack master to change the stack member number.
switch current-stack-member-number renumber new-stack-member-number
Note This command is supported only on Catalyst 3750-X switches.
Syntax Description
current-stack-member-number |
Specify the current stack member number. The range is 1 to 9. |
renumber new-stack-member-number |
Specify the new stack member number for the stack member. The range is 1 to 9. |
Defaults
The default stack member number is 1.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
If another stack member is already using the member number that you just specified, the stack master assigns the lowest available number when you reload the stack member.
Note If you change the number of a stack member, and no configuration is associated with the new stack member number, that stack member loses its current configuration and resets to its default configuration. For more information about stack member numbers and configurations, see the software configuration guide.
Do not use the switch current-stack-member-number renumber new-stack-member-number command on a provisioned switch. If you do, the command is rejected.
Use the reload slot current stack member number privileged EXEC to reload the stack member and to apply this configuration change.
Examples
This example shows how to change the member number of stack member 6 to 7:
Switch(config)# switch 6 renumber 7
WARNING:Changing the switch number may result in a configuration change for that switch.
The interface configuration associated with the old switch number will remain as a provisioned configuration.
Do you want to continue?[confirm]
Related Commands
|
|
reload |
Reloads the stack member and puts a configuration change into effect. |
session |
Accesses a specific stack member. |
switch priority |
Changes the stack member priority value. |
show switch |
Displays information about the switch stack and its stack members. |
switchport
Use the switchport interface configuration command with no keywords on the switch stack or on a standalone switch to put an interface that is in Layer 3 mode into Layer 2 mode for Layer 2 configuration. Use the no form of this command to put an interface in Layer 3 mode.
switchport
no switchport
Use the no switchport command (without parameters) to set the interface to the routed-interface status and to erase all Layer 2 configurations. You must use this command before assigning an IP address to a routed port.
Note This command (with no keywords) is not supported on switches running the LAN base feature set.
Syntax Description
This command has no arguments or keywords.
Defaults
By default, all interfaces are in Layer 2 mode.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
Entering the no switchport command shuts the port down and then re-enables it, which might generate messages on the device to which the port is connected.
When you put an interface that is in Layer 2 mode into Layer 3 mode (or the reverse), the previous configuration information related to the affected interface might be lost, and the interface is returned to its default configuration.
Note If an interface is configured as a Layer 3 interface, you must first enter this switchport command with no keywords to configure the interface as a Layer 2 port. Then you can enter additional switchport commands with keywords, as shown on the pages that follow.
Examples
This example shows how to cause an interface to cease operating as a Layer 2 port and become a Cisco-routed port:
Switch(config-if)# no switchport
This example shows how to cause the port interface to cease operating as a Cisco-routed port and convert to a Layer 2 switched interface:
Switch(config-if)# switchport
Note The switchport command without keywords is not used on platforms that do not support Cisco-routed ports. All physical ports on such platforms are assumed to be Layer 2-switched interfaces.
You can verify the switchport status of an interface by entering the show running-config privileged EXEC command.
switchport access
Use the switchport access interface configuration command on the switch stack or on a standalone switch to configure a port as a static-access or dynamic-access port. If the switchport mode is set to access, the port operates as a member of the specified VLAN. If set to dynamic, the port starts discovery of VLAN assignment based on the incoming packets it receives. Use the no form of this command to reset the access mode to the default VLAN for the switch.
switchport access vlan { vlan-id | dynamic }
no switchport access vlan
Syntax Description
vlan vlan-id |
Configure the interface as a static access port with the VLAN ID of the access mode VLAN; the range is 1 to 4094. |
vlan dynamic |
Specify that the access mode VLAN is dependent on the VLAN Membership Policy Server (VMPS) protocol. The port is assigned to a VLAN based on the source MAC address of a host (or hosts) connected to the port. The switch sends every new MAC address received to the VMPS server to get the VLAN name to which the dynamic-access port should be assigned. If the port already has a VLAN assigned and the source has already been approved by the VMPS, the switch forwards the packet to the VLAN. |
Defaults
The default access VLAN and trunk interface native VLAN is a default VLAN corresponding to the platform or interface hardware.
A dynamic-access port is initially a member of no VLAN and receives its assignment based on the packet it receives.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
The no switchport access command resets the access mode VLAN to the appropriate default VLAN for the device.
The port must be in access mode before the switchport access vlan command can take effect.
An access port can be assigned to only one VLAN.
The VMPS server (such as a Catalyst 6000 series switch) must be configured before a port is configured as dynamic.
These restrictions apply to dynamic-access ports:
- The software implements the VLAN Query Protocol (VQP) client, which can query a VMPS such as a Catalyst 6000 series switch. The Catalyst 3750-X and 3560-X switches are not VMPS servers. The VMPS server must be configured before a port is configured as dynamic.
- Use dynamic-access ports only to connect end stations. Connecting them to switches or routers (that use bridging protocols) can cause a loss of connectivity.
- Configure the network so that STP does not put the dynamic-access port into an STP blocking state. The Port Fast feature is automatically enabled on dynamic-access ports.
- Dynamic-access ports can only be in one VLAN and do not use VLAN tagging.
- Dynamic-access ports cannot be configured as
– Members of an EtherChannel port group (dynamic-access ports cannot be grouped with any other port, including other dynamic ports).
– Source or destination ports in a static address entry.
– Monitor ports.
Examples
This example shows how to change a switched port interface that is operating in access mode to operate in VLAN 2 instead of the default VLAN:
Switch(config-if)# switchport access vlan 2
You can verify your setting by entering the show interfaces interface-id switchport privileged EXEC command and examining information in the Administrative Mode and Operational Mode rows.
Related Commands
|
|
show interfaces switchport |
Displays the administrative and operational status of a switching (nonrouting) port, including port blocking and port protection settings. |
switchport mode |
Configures the VLAN membership mode of a port. |
switchport autostate exclude
Use the switchport autostate exclude interface configuration command to exclude an interface from the VLAN interface (switch virtual interface) line-state up or down calculation. Use the no form of this command to return to the default setting.
switchport autostate exclude
no switchport autostate exclude
Note This command is not supported on switches running the LAN base feature set.
Syntax Description
This command has no arguments or keywords.
Defaults
All ports in the VLAN are included in the VLAN interface link-up calculation.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
Enter the switchport autostate exclude command on a Layer 2 access or trunk port belonging to an SVI.
A VLAN interface (SVI) is up if ports are forwarding traffic in the associated VLAN. When all ports on a VLAN are down or blocking, the SVI is down. For the SVI to be up, at least one port in the VLAN must be up and forwarding. You can use the switchport autostate exclude command to exclude a port from the SVI interface line-state up-or-down calculation. For example, you might exclude a monitoring port from the calculations so that the VLAN is not considered up when only the monitoring port is active.
When you enter the switchport autostate exclude command on a port, the command applies to all VLANs that are enabled on the port.
You can verify the autostate mode of an interface by entering the show interface interface-id switchport privileged EXEC command. If the mode has not been set, the autostate mode does not appear.
Examples
This example shows how to configure autostate exclude on an interface and to verify the configuration:
Switch(config)#interface gigabitethernet 1/0/1
Switch(config-if)#switchport autostate exclude
Switch#show interface gigabitethernet1/0/1 switchport
Administrative Mode: dynamic auto
Administrative Trunking Encapsulation: negotiate
Negotiation of Trunking: On
Access Mode VLAN: 1 (default)
Trunking Native Mode VLAN: 1 (default)
Administrative Native VLAN tagging: enabled
Administrative private-vlan host-association: none
Administrative private-vlan mapping: none
Administrative private-vlan trunk native VLAN: none
Administrative private-vlan trunk Native VLAN tagging: enabled
Administrative private-vlan trunk encapsulation: dot1q
Administrative private-vlan trunk normal VLANs: none
Administrative private-vlan trunk associations: none
Administrative private-vlan trunk mappings: none
Operational private-vlan: none
Trunking VLANs Enabled: ALL
Pruning VLANs Enabled: 2-1001
Capture VLANs Allowed: ALL
Related Commands
|
|
show interfaces [ interface-id ] switchport |
Displays the administrative and operational status of a switching (nonrouting) port, including autostate mode, if set. |
show running-config |
Displays the current operating configuration. For syntax information, select Cisco IOS Configuration Fundamentals Command Reference, Release 12.2 > File Management Commands > Configuration File Management Commands. |
switchport backup interface
Use the switchport backup interface interface configuration command on a Layer 2 interface on the switch stack or on a standalone switch to configure Flex Links, a pair of interfaces that provide backup to each other.
Use the no form of this command to remove the Flex Links configuration.
switchport backup interface [FastEthernet interface-name | GigabitEthernet interface-name | Port-channel interface-name | TenGigabitEthernet interface-name ] {mmu primary vlan interface-name | multicast fast-convergence | preemption {delay interface-name | mode} | prefer vlan name}
no switchport backup interface [FastEthernet interface-name | GigabitEthernet interface-name | Port-channel interface-name | TenGigabitEthernet interface-name] {mmu primary vlan interface-name | multicast fast-convergence | preemption {delay interface-name | mode} | prefer vlan name}
Syntax Description
FastEthernet |
FastEthernet IEEE 802.3 port name. Valid range is 0 to 9. |
GigabitEthernet |
GigabitEthernet IEEE 802.3z port name. Valid range is 0 to 9. |
Port-channel |
Ethernet Channel of interface. Valid range is 0 to 48. |
TenGigabitEthernet |
Ten Gigabit Ethernet port name. Valid range is 0 to 9. |
mmu |
MAC-address move update. Configure the MAC move update (MMU) for a backup interface pair. |
primary |
MAC-address move update primary VLAN ID number. Valid range is 0 to 4,094. |
multicast |
Multicast parameters. |
fast-convergence |
Fast-convergence parameter. |
preemption |
Configure a preemption scheme for a backup interface pair. |
delay |
Preemption parameters in seconds. Valid range is 1 to 300. |
mode |
Set the preemption mode. |
prefer |
Load-balancing. |
vlan vlan-name |
The VLAN ID of the primary VLAN. Valid range is 1 to 4,094. |
Defaults
The default is to have no Flex Links defined. The preemption mode is off. No preemption occurs. Preemption delay is set to 35 seconds.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
With Flex Links configured, one link acts as the primary interface and forwards traffic, while the other interface is in standby mode, ready to begin forwarding traffic if the primary link shuts down. The interface being configured is referred to as the active link; the specified interface is identified as the backup link. The feature provides an alternative to the Spanning Tree Protocol (STP), allowing users to turn off STP and still retain basic link redundancy.
- This command is available only for Layer 2 interfaces.
- You can configure only one Flex Link backup link for any active link, and it must be a different interface from the active interface.
- An interface can belong to only one Flex Link pair. An interface can be a backup link for only one active link. An active link cannot belong to another Flex Link pair.
- A backup link does not have to be the same type (Fast Ethernet or Gigabit Ethernet, for instance) as the active link. However, you should configure both Flex Links with similar characteristics so that there are no loops or changes in behavior if the standby link begins to forward traffic.
- Neither of the links can be a port that belongs to an EtherChannel. However, you can configure two port channels (EtherChannel logical interfaces) as Flex Links, and you can configure a port channel and a physical interface as Flex Links, with either the port channel or the physical interface as the active link.
- If STP is configured on the switch, Flex Links do not participate in STP in all valid VLANs. If STP is not running, be sure that there are no loops in the configured topology.
Examples
This example shows how to configure two interfaces as Flex Links:
Switch# configure terminal
Switch(conf)# interface gigabitethernet1/0/1
Switch(conf-if)# switchport backup interface gigabitethernet1/0/2
This example shows how to configure the Gigabit Ethernet interface to always preempt the backup:
Switch# configure terminal
Switch(conf)# interface gigabitethernet1/0/1
Switch(conf-if)# switchport backup interface gigabitethernet1/0/2 preemption forced
This example shows how to configure the Gigabit Ethernet interface preemption delay time:
Switch# configure terminal
Switch(conf)# interface gigabitethernet1/0/1
Switch(conf-if)# switchport backup interface gigabitethernet1/0/2 preemption delay 150
This example shows how to configure the Gigabit Ethernet interface as the MMU primary VLAN:
Switch# configure terminal
Switch(conf)# interface gigabitethernet1/0/1
Switch(conf-if)# switchport backup interface gigabitethernet1/0/2 mmu primary vlan 1021
You can verify your setting by entering the show interfaces switchport backup privileged EXEC command.
Related Commands
|
|
show interfaces [ interface-id ] switchport backup |
Displays the configured Flex Links and their status on the switch or for the specified interface. |
switchport block
Use the switchport block interface configuration command on the switch stack or on a standalone switch to prevent unknown multicast or unicast packets from being forwarded. Use the no form of this command to allow forwarding unknown multicast or unicast packets.
switchport block { multicast | unicast }
no switchport block { multicast | unicast }
Syntax Description
multicast |
Specify that unknown multicast traffic should be blocked. Note Only pure Layer 2 multicast traffic is blocked. Multicast packets that contain IPv4 or IPv6 information in the header are not blocked. |
unicast |
Specify that unknown unicast traffic should be blocked. |
Defaults
Unknown multicast and unicast traffic is not blocked.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
By default, all traffic with unknown MAC addresses is sent to all ports. You can block unknown multicast or unicast traffic on protected or nonprotected ports. If unknown multicast or unicast traffic is not blocked on a protected port, there could be security issues.
With multicast traffic, the port blocking feature blocks only pure Layer 2 packets. Multicast packets that contain IPv4 or IPv6 information in the header are not blocked.
Blocking unknown multicast or unicast traffic is not automatically enabled on protected ports; you must explicitly configure it.
For more information about blocking packets, see the software configuration guide for this release.
Examples
This example shows how to block unknown unicast traffic on an interface:
Switch(config-if)# switchport block unicast
You can verify your setting by entering the show interfaces interface-id switchport privileged EXEC command.
Related Commands
|
|
show interfaces switchport |
Displays the administrative and operational status of a switching (nonrouting) port, including port blocking and port protection settings. |
switchport host
Use the switchport host interface configuration command on the switch stack or on a standalone switch to optimize a Layer 2 port for a host connection. The no form of this command has no affect on the system.
switchport host
Syntax Description
This command has no arguments or keywords.
Defaults
The default is for the port to not be optimized for a host connection.
Command Modes
I nterface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
To optimize the port for a host connection, the switchport host command sets switch port mode to access, enables spanning tree Port Fast, and disables channel grouping. Only an end station can accept this configuration.
Because spanning tree Port Fast is enabled, you should enter the switchport host command only on ports that are connected to a single host. Connecting other switches, hubs, concentrators, or bridges to a fast-start port can cause temporary spanning-tree loops.
Enable the switchport host command to decrease the time that it takes to start up packet forwarding.
Examples
This example shows how to optimize the port configuration for a host connection:
Switch(config-if)# switchport host
switchport mode will be set to access
spanning-tree portfast will be enabled
channel group will be disabled
You can verify your setting by entering the show interfaces interface-id switchport privileged EXEC command.
Related Commands
|
|
show interfaces switchport |
Displays the administrative and operational status of a switching (nonrouting) port, including switchport mode. |
switchport mode
Use the switchport mode interface configuration command on the switch stack or on a standalone switch to configure the VLAN membership mode of a port. Use the no form of this command to reset the mode to the appropriate default for the device.
switchport mode { access | dot1q-tunnel | dynamic { auto | desirable } | private-vlan | trunk }
no switchport mode { access | dot1q-tunnel | dynamic | trunk }
Syntax Description
access |
Set the port to access mode (either static-access or dynamic-access depending on the setting of the switchport access vlan interface configuration command). The port is set to access unconditionally and operates as a nontrunking, single VLAN interface that sends and receives nonencapsulated (non-tagged) frames. An access port can be assigned to only one VLAN. |
dot1q-tunnel |
Set the port as an IEEE 802.1Q tunnel port. |
dynamic auto |
Set the interface trunking mode dynamic parameter to auto to specify that the interface convert the link to a trunk link. This is the default switchport mode. |
dynamic desirable |
Set the interface trunking mode dynamic parameter to desirable to specify that the interface actively attempt to convert the link to a trunk link. |
private-vlan |
See the switchport mode private-vlan command. |
trunk |
Set the port to trunk unconditionally. The port is a trunking VLAN Layer 2 interface. The port sends and receives encapsulated (tagged) frames that identify the VLAN of origination. A trunk is a point-to-point link between two switches or between a switch and a router. |
Defaults
The default mode is dynamic auto.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
A configuration that uses the access, dot1q-tunnel , or trunk keywords takes effect only when you configure the port in the appropriate mode by using the switchport mode command. The static-access and trunk configuration are saved, but only one configuration is active at a time.
When you enter access mode, the interface changes to permanent nontrunking mode and negotiates to convert the link into a nontrunk link even if the neighboring interface does not agree to the change.
When you enter trunk mode, the interface changes to permanent trunking mode and negotiates to convert the link into a trunk link even if the interface connecting to it does not agree to the change.
When you enter dynamic auto mode, the interface converts the link to a trunk link if the neighboring interface is set to trunk or desirable mode.
When you enter dynamic desirable mode, the interface becomes a trunk interface if the neighboring interface is set to trunk, desirable, or auto mode.
To autonegotiate trunking, the interfaces must be in the same VLAN Trunking Protocol (VTP) domain. Trunk negotiation is managed by the Dynamic Trunking Protocol ( DTP), which is a point-to-point protocol. However, some internetworking devices might forward DTP frames improperly, which could cause misconfigurations. To avoid this, you should configure interfaces connected to devices that do not support DTP to not forward DTP frames, which turns off DTP.
- If you do not intend to trunk across those links, use the switchport mode a ccess interface configuration command to disable trunking.
- To enable trunking to a device that does not support DTP, use the switchport mode trunk and switchport nonegotiate interface configuration commands to cause the interface to become a trunk but to not generate DTP frames.
When you enter dot1q-tunnel, the port is set unconditionally as an IEEE 802.1Q tunnel port.
Access ports, trunk ports, and tunnel ports are mutually exclusive.
Any IEEE 802.1Q encapsulated IP packets received on a tunnel port can be filtered by MAC access control lists (ACLs), but not by IP ACLs. This is because the switch does not recognize the protocol inside the IEEE 802.1Q header. This restriction applies to router ACLs, port ACLs, and VLAN maps.
Configuring a port as an IEEE 802.1Q tunnel port has these limitations:
- IP routing and fallback bridging are not supported on tunnel ports.
- Tunnel ports do not support IP ACLs.
- If an IP ACL is applied to a trunk port in a VLAN that includes tunnel ports, or if a VLAN map is applied to a VLAN that includes tunnel ports, packets received from the tunnel port are treated as non-IP packets and are filtered with MAC access lists.
- Layer 3 quality of service (QoS) ACLs and other QoS features related to Layer 3 information are not supported on tunnel ports.
For more information about configuring IEEE 802.1Q tunnel ports, see the software configuration guide for this release.
The IEEE 802.1x feature interacts with switchport modes in these ways:
- If you try to enable IEEE 802.1x on a trunk port, an error message appears, and IEEE 802.1x is not enabled. If you try to change the mode of an IEEE 802.1x-enabled port to trunk, the port mode is not changed.
- If you try to enable IEEE 802.1x on a port set to dynamic auto or dynamic desirable, an error message appears, and IEEE 802.1x is not enabled. If you try to change the mode of an IEEE 802.1x-enabled port to dynamic auto or dynamic desirable, the port mode is not changed.
- If you try to enable IEEE 802.1x on a dynamic-access (VLAN Query Protocol [VQP]) port, an error message appears, and IEEE 802.1x is not enabled. If you try to change an IEEE 802.1x-enabled port to dynamic VLAN assignment, an error message appears, and the VLAN configuration is not changed.
Examples
This example shows how to configure a port for access mode:
Switch(config)# interface gigabitethernet2/0/1
Switch(config-if)# switchport mode access
This example shows how set the port to dynamic desirable mode:
Switch(config)# interface gigabitethernet2/0/1
Switch(config-if)# switchport mode dynamic desirable
This example shows how to configure a port for trunk mode:
Switch(config)# interface gigabitethernet2/0/1
Switch(config-if)# switchport mode trunk
This example shows how to configure a port as an IEEE 802.1Q tunnel port:
Switch(config)# interface gigabitethernet2/0/1
Switch(config-if)# switchport mode dot1q-tunnel
You can verify your settings by entering the show interfaces interface-id switchport privileged EXEC command and examining information in the Administrative Mode and Operational Mode rows.
Related Commands
|
|
show interfaces switchport |
Displays the administrative and operational status of a switching (nonrouting) port, including port blocking and port protection settings. |
switchport access |
Configures a port as a static-access or dynamic-access port. |
switchport trunk |
Configures the trunk characteristics when an interface is in trunking mode. |
switchport mode private-vlan
Use the switchport mode private-vlan interface configuration command on the switch stack or on a standalone switch to configure a port as a promiscuous or host private VLAN port. Use the no form of this command to reset the mode to the appropriate default for the device.
switchport mod e private-vlan { host | promiscuous }
no switchport mode private-vlan
Note This command is not supported on switches running the LAN base feature set.
Syntax Description
host |
Configure the interface as a private-VLAN host port. Host ports belong to private-VLAN secondary VLANs and are either community ports or isolated ports, depending on the VLAN that they belong to. |
promiscuous |
Configure the interface as a private-VLAN promiscuous port. Promiscuous ports are members of private-VLAN primary VLANs. |
Defaults
The default private-VLAN mode is neither host nor promiscuous.
The default switchport mode is dynamic auto.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
A private-VLAN host or promiscuous port cannot be a Switched Port Analyzer (SPAN) destination port. If you configure a SPAN destination port as a private-VLAN host or promiscuous port, the port becomes inactive.
Do not configure private VLAN on ports with these other features:
- Dynamic-access port VLAN membership
- Dynamic Trunking Protocol (DTP)
- Port Aggregation Protocol (PAgP)
- Link Aggregation Control Protocol (LACP)
- Multicast VLAN Registration (MVR)
- Voice VLAN
A private-VLAN port cannot be a SPAN destination port.
While a port is part of the private-VLAN configuration, any EtherChannel configuration for it is inactive.
A private-VLAN port cannot be a secure port and should not be configured as a protected port.
For more information about private-VLAN interaction with other features, see the software configuration guide for this release.
We strongly recommend that you enable spanning tree Port Fast and bridge-protocol-data-unit (BPDU) guard on isolated and community host ports to prevent STP loops due to misconfigurations and to speed up STP convergence.
If you configure a port as a private-VLAN host port and you do not configure a valid private-VLAN association by using the switchport private-vlan host-association interface configuration command, the interface becomes inactive.
If you configure a port as a private-VLAN promiscuous port and you do not configure a valid private VLAN mapping by using the switchport private-vlan mapping interface configuration command, the interface becomes inactive.
Examples
This example shows how to configure an interface as a private-VLAN host port and associate it to primary VLAN 20. The interface is a member of secondary isolated VLAN 501 and primary VLAN 20.
Note When you configure a port as a private VLAN host port, you should also enable BPDU guard and Port Fast by using the spanning-tree portfast bpduguard default global configuration command and the spanning-tree portfast interface configuration command.
Switch# configure terminal
Switch(config)# interface gigabitethernet 1/0/1
Switch(config-if)# switchport mode private-vlan host
Switch(config-if)# switchport private-vlan host-association 20 501
This example shows how to configure an interface as a private VLAN promiscuous port and map it to a private VLAN. The interface is a member of primary VLAN 20 and secondary VLANs 501 to 503 are mapped to it.
Switch# configure terminal
Switch(config)# interface gigabitethernet 1/0/2
Switch(config-if)# switchport mode private-vlan promiscuous
Switch(config-if)# switchport private-vlan mapping 20 501-503
You can verify private VLAN switchport mode by using the show interfaces interface-id switchport privileged EXEC command.
Related Commands
|
|
private-vlan |
Configures a VLAN as a community, isolated, or primary VLAN or associates a primary VLAN with secondary VLANs. |
show interfaces switchport |
Displays the administrative and operational status of a switching (nonrouting) port, including private VLAN configuration. |
switchport private-vlan |
Configures private VLAN associations and mappings between primary and secondary VLANs on an interface. |
switchport nonegotiate
Use the switchport nonegotiate interface configuration command on the switch stack or on a standalone switch to specify that Dynamic Trunking Protocol (DTP) negotiation packets are not sent on the Layer 2 interface. The switch does not engage in DTP negotiation on this interface. Use the no form of this command to return to the default setting.
switchport nonegotiate
no switchport nonegotiate
Syntax Description
This command has no arguments or keywords.
Defaults
The default is to use DTP negotiation to learn the trunking status.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
The no form of the switchport nonegotiate command removes nonegotiate status.
This command is valid only when the interface switchport mode is access or trunk (configured by using the switchport mode access or the switchport mode trunk interface configuration command). This command returns an error if you attempt to execute it in dynamic (auto or desirable) mode.
Internetworking devices that do not support DTP might forward DTP frames improperly and cause misconfigurations. To avoid this, you should turn off DTP by using the switchport no negotiate command to configure the interfaces connected to devices that do not support DTP to not forward DTP frames.
When you enter the switchport nonegotiate command, DTP negotiation packets are not sent on the interface. The device does or does not trunk according to the mode parameter: access or trunk.
- If you do not intend to trunk across those links, use the switchport mode a ccess interface configuration command to disable trunking.
- To enable trunking on a device that does not support DTP, use the switchport mode trunk and switchport nonegotiate interface configuration commands to cause the interface to become a trunk but to not generate DTP frames.
Examples
This example shows how to cause a port to refrain from negotiating trunking mode and to act as a trunk or access port (depending on the mode set):
Switch(config)# interface gigabitethernet2/0/1
Switch(config-if)# switchport nonegotiate
You can verify your setting by entering the show interfaces interface-id switchport privileged EXEC command.
Related Commands
|
|
show interfaces switchport |
Displays the administrative and operational status of a switching (nonrouting) port, including port blocking and port protection settings. |
switchport mode |
Configures the VLAN membership mode of a port. |
switchport port-security
Use the switchport port-security interface configuration command without keywords on the switch stack or on a standalone switch to enable port security on the uplink interface. Use the keywords to configure secure MAC addresses, sticky MAC address learning, a maximum number of secure MAC addresses, or the violation mode. Use the no form of this command to disable port security or to set the parameters to their default states.
switchport port-security [ mac-address mac-address [ vlan { vlan-id | { access | voice }}] | mac-address sticky [ mac-address | vlan { vlan-id | { access | voice }}]] [ maximum value [ vlan { vlan-list | { access | voice }}]]
no switchport port-security [ mac-address mac-address [ vlan { vlan-id | { access | voice }}] | mac-address sticky [ mac-address | vlan { vlan-id | { access | voice }}]] [ maximum value [ vlan { vlan-list | { access | voice }}]]
switchport port-security [ aging ] [ violation { protect | restrict | shutdown | shutdown vlan}]
no switchport port-security [ aging ] [ violation { protect | restrict | shutdown | shutdown vlan}]
Syntax Description
aging |
(Optional) See the switchport port-security aging command. |
mac-address mac-address |
(Optional) Specify a secure MAC address for the interface by entering a 48-bit MAC address. You can add additional secure MAC addresses up to the maximum value configured. |
vlan vlan-id |
(Optional) On a trunk port only, specify the VLAN ID and the MAC address. If no VLAN ID is specified, the native VLAN is used. |
vlan access |
(Optional) On an access port only, specify the VLAN as an access VLAN. |
vlan voice |
(Optional) On an access port only, specify the VLAN as a voice VLAN. Note The voice keyword is available only if voice VLAN is configured on a port and if that port is not the access VLAN. |
mac-address sticky [ mac-address ] |
(Optional) Enable the interface for sticky learning by entering only the mac-address sticky keywords. When sticky learning is enabled, the interface adds all secure MAC addresses that are dynamically learned to the running configuration and converts these addresses to sticky secure MAC addresses. (Optional) Enter a mac-address to specify a sticky secure MAC address. |
maximum value |
(Optional) Set the maximum number of secure MAC addresses for the interface.The maximum number of secure MAC addresses that you can configure on a switch or switch stack is set by the maximum number of available MAC addresses allowed in the system. This number is determined by the active Switch Database Management (SDM) template. See the sdm prefer command. This number represents the total of available MAC addresses, including those used for other Layer 2 functions and any other secure MAC addresses configured on interfaces. The default setting is 1. |
vlan [ vlan-list ] |
(Optional) For trunk ports, you can set the maximum number of secure MAC addresses on a VLAN. If the vlan keyword is not entered, the default value is used.
- vlan —set a per-VLAN maximum value.
- vlan vlan-list —set a per-VLAN maximum value on a range of VLANs separated by a hyphen or a series of VLANs separated by commas. For nonspecified VLANs, the per-VLAN maximum value is used.
|
violation |
(Optional) Set the security violation mode or the action to be taken if port security is violated. The default is shutdown. |
protect |
Set the security violation protect mode. In this mode, when the number of port secure MAC addresses reaches the maximum limit allowed on the port, packets with unknown source addresses are dropped until you remove a sufficient number of secure MAC addresses to drop below the maximum value or increase the number of maximum allowable addresses. You are not notified that a security violation has occurred. Note We do not recommend configuring the protect mode on a trunk port. The protect mode disables learning when any VLAN reaches its maximum limit, even if the port has not reached its maximum limit. |
restrict |
Set the security violation restrict mode. In this mode, when the number of secure MAC addresses reaches the limit allowed on the port, packets with unknown source addresses are dropped until you remove a sufficient number of secure MAC addresses or increase the number of maximum allowable addresses. An SNMP trap is sent, a syslog message is logged, and the violation counter increments. |
shutdown |
Set the security violation shutdown mode. In this mode, the interface is error-disabled when a violation occurs and the port LED turns off. An SNMP trap is sent, a syslog message is logged, and the violation counter increments. When a secure port is in the error-disabled state, you can bring it out of this state by entering the errdisable recovery cause psecure-violation global configuration command, or you can manually re-enable it by entering the shutdown and no shut down interface configuration commands. |
shutdown vlan |
Set the security violation mode to per-VLAN shutdown. In this mode, only the VLAN on which the violation occurred is error-disabled. |
Defaults
The default is to disable port security.
When port security is enabled and no keywords are entered, the default maximum number of secure MAC addresses is 1.
The default violation mode is shutdown.
Sticky learning is disabled.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
A secure port has the following limitations:
- A secure port can be an access port or a trunk port; it cannot be a dynamic access port.
- A secure port cannot be a routed port.
- A secure port cannot be a protected port.
- A secure port cannot be a destination port for Switched Port Analyzer (SPAN).
- A secure port cannot belong to a Gigabit or 10-Gigabit EtherChannel port group.
- You cannot configure static secure or sticky secure MAC addresses in the voice VLAN.
- When you enable port security on an interface that is also configured with a voice VLAN, set the maximum allowed secure addresses on the port to two. When the port is connected to a Cisco IP phone, the IP phone requires one MAC address. The Cisco IP phone address is learned on the voice VLAN, but is not learned on the access VLAN. If you connect a single PC to the Cisco IP phone, no additional MAC addresses are required. If you connect more than one PC to the Cisco IP phone, you must configure enough secure addresses to allow one for each PC and one for the Cisco IP phone.
- Voice VLAN is supported only on access ports and not on trunk ports.
- When you enter a maximum secure address value for an interface, if the new value is greater than the previous value, the new value overrides the previously configured value. If the new value is less than the previous value and the number of configured secure addresses on the interface exceeds the new value, the command is rejected.
- The switch does not support port security aging of sticky secure MAC addresses.
A security violation occurs when the maximum number of secure MAC addresses are in the address table and a station whose MAC address is not in the address table attempts to access the interface or when a station whose MAC address is configured as a secure MAC address on another secure port attempts to access the interface.
When a secure port is in the error-disabled state, you can bring it out of this state by entering the errdisable recovery cause psecure-violation global configuration command. You can manually re-enable the port by entering the shutdown and no shut down interface configuration commands or by using the clear errdisable interface privileged EXEC command.
Setting a maximum number of addresses to one and configuring the MAC address of an attached device ensures that the device has the full bandwidth of the port.
When you enter a maximum secure address value for an interface, this occurs:
- If the new value is greater than the previous value, the new value overrides the previously configured value.
- If the new value is less than the previous value and the number of configured secure addresses on the interface exceeds the new value, the command is rejected.
Sticky secure MAC addresses have these characteristics:
- When you enable sticky learning on an interface by using the switchport port-security mac-address sticky interface configuration command, the interface converts all the dynamic secure MAC addresses, including those that were dynamically learned before sticky learning was enabled, to sticky secure MAC addresses and adds all sticky secure MAC addresses to the running configuration.
- If you disable sticky learning by using the no switchport port-security mac-address sticky interface configuration command or the running configuration is removed, the sticky secure MAC addresses remain part of the running configuration but are removed from the address table. The addresses that were removed can be dynamically reconfigured and added to the address table as dynamic addresses.
- When you configure sticky secure MAC addresses by using the switchport port-security mac-address sticky mac-address interface configuration command, these addresses are added to the address table and the running configuration. If port security is disabled, the sticky secure MAC addresses remain in the running configuration.
- If you save the sticky secure MAC addresses in the configuration file, when the switch restarts or the interface shuts down, the interface does not need to relearn these addresses. If you do not save the sticky secure addresses, they are lost. If sticky learning is disabled, the sticky secure MAC addresses are converted to dynamic secure addresses and are removed from the running configuration.
- If you disable sticky learning and enter the switchport port-security mac-address sticky mac-address interface configuration command, an error message appears, and the sticky secure MAC address is not added to the running configuration.
Examples
This example shows how to enable port security on a port and to set the maximum number of secure addresses to 5. The violation mode is the default, and no secure MAC addresses are configured.
Switch(config)# interface gigabitethernet 2/0/2
Switch(config-if)# switchport mode access
Switch(config-if)# switchport port-security
Switch(config-if)# switchport port-security maximum 5
This example shows how to configure a secure MAC address and a VLAN ID on a port:
Switch(config)# interface gigabitethernet 2/0/2
Switch(config-if)# switchport mode trunk
Switch(config-if)# switchport port-security
Switch(config-if)# switchport port-security mac-address 1000.2000.3000 vlan 3
This example shows how to enable sticky learning and to enter two sticky secure MAC addresses on a port:
Switch(config)# interface gigabitethernet 2/0/2
Switch(config-if)# switchport port-security mac-address sticky
Switch(config-if)# switchport port-security mac-address sticky 0000.0000.4141
Switch(config-if)# switchport port-security mac-address sticky 0000.0000.000f
This example show how to configure a port to shut down only the VLAN if a violation occurs:
Switch(config)# interface gigabitethernet2/0/2
Switch(config)# switchport port-security violation shutdown vlan
You can verify your settings by using the show port-security privileged EXEC command.
Related Commands
|
|
clear port-security |
Deletes from the MAC address table a specific type of secure address or all the secure addresses on the switch or an interface. |
show port-security address |
Displays all the secure addresses configured on the switch. |
show port-security interface interface-id |
Displays port security configuration for the switch or for the specified interface. |
switchport port-security aging
Use the switchport port-security aging interface configuration command on the switch stack or on a standalone switch to set the aging time and type for secure address entries or to change the aging behavior for secure addresses on a particular port. Use the no form of this command to disable port security aging or to set the parameters to their default states.
switchport port-security aging { static | time time | type { absolute | inactivity }}
no switchport port-security aging { static | time | type }
Syntax Description
static |
Enable aging for statically configured secure addresses on this port. |
time time |
Specify the aging time for this port. The range is 0 to 1440 minutes. If the time is 0, aging is disabled for this port. |
type |
Set the aging type. |
absolute |
Set absolute aging type. All the secure addresses on this port age out exactly after the time (minutes) specified and are removed from the secure address list. |
inactivity |
Set the inactivity aging type. The secure addresses on this port age out only if there is no data traffic from the secure source address for the specified time period. |
Defaults
The port security aging feature is disabled. The default time is 0 minutes.
The default aging type is absolute.
The default static aging behavior is disabled.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
To enable secure address aging for a particular port, set the aging time to a value other than 0 for that port.
To allow limited time access to particular secure addresses, set the aging type as absolute. When the aging time lapses, the secure addresses are deleted.
To allow continuous access to a limited number of secure addresses, set the aging type as inactivity. This removes the secure address when it become inactive, and other addresses can become secure.
To allow unlimited access to a secure address, configure it as a secure address, and disable aging for the statically configured secure address by using the no switchport port-security aging static interface configuration command.
Examples
This example sets the aging time as 2 hours for absolute aging for all the secure addresses on the port:
Switch(config)# interface gigabitethernet1/0/1
Switch(config-if)# switchport port-security aging time 120
This example sets the aging time as 2 minutes for inactivity aging type with aging enabled for configured secure addresses on the port:
Switch(config)# interface gigabitethernet1/0/2
Switch(config-if)# switchport port-security aging time 2
Switch(config-if)# switchport port-security aging type inactivity
Switch(config-if)# switchport port-security aging static
This example shows how to disable aging for configured secure addresses:
Switch(config)# interface gigabitethernet1/0/2
Switch(config-if)# no switchport port-security aging static
Related Commands
|
|
show port-security |
Displays the port security settings defined for the port. |
switchport port-security |
Enables port security on a port, restricts the use of the port to a user-defined group of stations, and configures secure MAC addresses. |
switchport priority extend
Use the switchport priority extend interface configuration command on the switch stack or on a standalone switch to set a port priority for the incoming untagged frames or the priority of frames received by the IP phone connected to the specified port. Use the no form of this command to return to the default setting.
switchport priority extend { cos value | trust }
no switchport priority extend
Syntax Description
cos value |
Set the IP phone port to override the IEEE 802.1p priority received from the PC or the attached device with the specified class of service (CoS) value. The range is 0 to 7. Seven is the highest priority. The default is 0. |
trust |
Set the IP phone port to trust the IEEE 802.1p priority received from the PC or the attached device. |
Defaults
The default port priority is set to a CoS value of 0 for untagged frames received on the port.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
When voice VLAN is enabled, you can configure the switch to send the Cisco Discovery Protocol (CDP) packets to instruct the IP phone how to send data packets from the device attached to the access port on the Cisco IP Phone. You must enable CDP on the switch port connected to the Cisco IP Phone to send the configuration to the Cisco IP Phone. (CDP is enabled by default globally and on all switch interfaces.)
You should configure voice VLAN on switch access ports. You can configure a voice VLAN only on Layer 2 ports.
Before you enable voice VLAN, we recommend that you enable quality of service (QoS) on the switch by entering the mls qos global configuration command and configure the port trust state to trust by entering the mls qos trust cos interface configuration command.
Examples
This example shows how to configure the IP phone connected to the specified port to trust the received IEEE 802.1p priority:
Switch(config)# interface gigabitethernet1/0/2
Switch(config-if)# switchport priority extend trust
You can verify your settings by entering the show interfaces interface-id switchport privileged EXEC command.
switchport private-vlan
Use the switchport private-vlan interface configuration command on the switch stack or on a standalone switch to define a private-VLAN association for an isolated or community port or a mapping for a promiscuous port. Use the no form of this command to remove the private-VLAN association or mapping from the port.
switchport private-vlan { association { host primary-vlan-id secondary-vlan-id | mapping primary-vlan-id { add | remove } secondary-vlan-list } | host-association primary-vlan-id secondary-vlan-id | mapping primary-vlan-id { add | remove } secondary-vlan-list }
no switchport private-vlan { association { host | mapping } | host-association | mapping
Note This command is not supported on switches running the LAN base feature set.
Syntax Description
association |
Define a private-VLAN association for a port. |
host |
Define a private-VLAN association for a community or isolated host port. |
primary-vlan-id |
The VLAN ID of the private-VLAN primary VLAN. The range is from 2 to 1001 and 1006 to 4094. |
secondary-vlan-id |
The VLAN ID of the private-VLAN secondary (isolated or community) VLAN. The range is from 2 to 1001 and 1006 to 4094. |
mapping |
Define private-VLAN mapping for a promiscuous port. |
add |
Associate secondary VLANs to the primary VLAN. |
remove |
Clear the association between secondary VLANs and the primary VLAN. |
secondary-vlan-list |
One or more secondary (isolated or community) VLANs to be mapped to the primary VLAN. |
host-association |
Define a private-VLAN association for a community or isolated host port. |
Defaults
The default is to have no private-VLAN association or mapping configured.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
Private-VLAN association or mapping has no effect on the port unless the port has been configured as a private-VLAN host or promiscuous port by using the switchport mod e private-vlan { host | promiscuous } interface configuration command.
If the port is in private-VLAN host or promiscuous mode but the VLANs do not exist, the command is allowed, but the port is made inactive.
The secondary_vlan_list parameter cannot contain spaces. It can contain multiple comma-separated items. Each item can be a single private-VLAN ID or a hyphenated range of private-VLAN IDs. The list can contain one isolated VLAN and multiple community VLANs.
You can map a promiscuous port to only one primary VLAN. If you enter the switchport private-vlan mapping command on a promiscuous port that is already mapped to a primary and secondary VLAN, the primary VLAN mapping is overwritten.
You can add or remove secondary VLANs from promiscuous port private-VLAN mappings by using the add and remove keywords.
Entering the switchport private-vlan association host command has the same effect as entering the switchport private-vlan host-association interface configuration command.
Entering the switchport private-vlan association mapping command has the same effect as entering the switchport private-vlan mapping interface configuration command.
Examples
This example shows how to configure an interface as a private VLAN host port and associate it with primary VLAN 20 and secondary VLAN 501:
Switch# configure terminal
Switch(config)# interface gigabitethernet 1/0/1
Switch(config-if)# switchport mode private-vlan host
Switch(config-if)# switchport private-vlan host-association 20 501
This example shows how to configure an interface as a private-VLAN promiscuous port and map it to a primary VLAN and secondary VLANs:
Switch# configure terminal
Switch(config)# interface gigabitethernet 1/0/2
Switch(config-if)# switchport mode private-vlan promiscuous
Switch(config-if)# switchport private-vlan mapping 20 501-502
You can verify private-VLAN mapping by using the show interfaces private-vlan mapping privileged EXEC command. You can verify private VLANs and interfaces configured on the switch stack by using the show vlan private-vlan privileged EXEC command.
Related Commands
|
|
show interfaces private-vlan mapping |
Displays private VLAN mapping information for VLAN SVIs. |
show vlan private-vlan |
Displays all private VLAN relationships or types configured on the switch or switch stack. |
switchport protected
Use the switch port protected interface configuration command on the switch stack or on a standalone switch to isolate unicast, multicast, and broadcast traffic at Layer 2 from other protected ports on the same switch. Use the no form of this command to disable protection on the port.
switchport protected
no switchport protected
Syntax Description
This command has no arguments or keywords.
Defaults
No protected port is defined. All ports are nonprotected.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
The switchport protection feature is local to the switch; communication between protected ports on the same switch is possible only through a Layer 3 device. To prevent communication between protected ports on different switches, you must configure the protected ports for unique VLANs on each switch and configure a trunk link between the switches. A protected port is different from a secure port.
A protected port does not forward any traffic (unicast, multicast, or broadcast) to any other port that is also a protected port. Data traffic cannot be forwarded between protected ports at Layer 2; only control traffic, such as PIM packets, is forwarded because these packets are processed by the CPU and forwarded in software. All data traffic passing between protected ports must be forwarded through a Layer 3 device.
Because a switch stack represents a single logical switch, Layer 2 traffic is not forwarded between any protected ports in the switch stack, whether they are on the same or different switches in the stack.
Port monitoring does not work if both the monitor and monitored ports are protected ports.
Examples
This example shows how to enable a protected port on an interface:
Switch(config)# interface gigabitethernet1/0/2
Switch(config-if)# switchport protected
You can verify your settings by entering the show interfaces interface-id switchport privileged EXEC command.
Related Commands
|
|
show interfaces switchport |
Displays the administrative and operational status of a switching (nonrouting) port, including port blocking and port protection settings. |
switchport block |
Prevents unknown multicast or unicast traffic on the interface. |
switchport trunk
Use the switchport trunk interface configuration command on the switch stack or on a standalone switch to set the trunk characteristics when the interface is in trunking mode. Use the no form of this command to reset a trunking characteristic to the default.
switchport trunk { allowed vlan vlan-list | encapsulation { dot1q | isl | negotiate } | native vlan vlan-id | pruning vlan vlan-list }
no switchport trunk { allowed vlan | encapsulation | native vlan | { pruning vlan }
Syntax Description
allowed vlan vlan-list |
Set the list of allowed VLANs that can receive and send traffic on this interface in tagged format when in trunking mode. See the following vlan-list format. The none keyword is not valid. The default is all. |
encapsulation dot1q |
Set the encapsulation format on the trunk port to IEEE 802.1Q. With this format, the switch supports simultaneous tagged and untagged traffic on a port. |
encapsulation isl |
Set the encapsulation format on the trunk port to Inter-Switch Link (ISL). The switch encapsulates all received and sent packets with an ISL header and filters native frames received from an ISL trunk port. |
encapsulation negotiate |
Specify that if Dynamic Inter-Switch Link (DISL) and Dynamic Trunking Protocol (DTP) negotiation do not resolve the encapsulation format, ISL is the selected format. |
native vlan vlan-id |
Set the native VLAN for sending and receiving untagged traffic when the interface is in IEEE 802.1Q trunking mode. The range is 1 to 4094. |
pruning vlan vlan-list |
Set the list of VLANs that are eligible for VTP pruning when in trunking mode. The all keyword is not valid. |
The vlan-list format is all | none | [ add | remove | except ] vlan-atom [ , vlan-atom... ] where:
- all specifies all VLANs from 1 to 4094. This keyword is not allowed on commands that do not permit all VLANs in the list to be set at the same time.
- none means an empty list. This keyword is not allowed on commands that require certain VLANs to be set or at least one VLAN to be set.
- add adds the defined list of VLANs to those currently set instead of replacing the list. Valid IDs are from 1 to 1005; extended-range VLANs (VLAN IDs greater than 1005) are valid in some cases.
Note You can add extended-range VLANs to the allowed VLAN list, but not to the pruning-eligible VLAN list.
Separate nonconsecutive VLAN IDs with a comma; use a hyphen to designate a range of IDs.
- remove removes the defined list of VLANs from those currently set instead of replacing the list. Valid IDs are from 1 to 1005; extended-range VLAN IDs are valid in some cases.
Note You can remove extended-range VLANs from the allowed VLAN list, but you cannot remove them from the pruning-eligible list.
Separate nonconsecutive VLAN IDs with a comma; use a hyphen to designate a range of IDs.
- except lists the VLANs that should be calculated by inverting the defined list of VLANs. (VLANs are added except the ones specified.) Valid IDs are from 1 to 1005. Separate nonconsecutive VLAN IDs with a comma; use a hyphen to designate a range of IDs.
- vlan-atom is either a single VLAN number from 1 to 4094 or a continuous range of VLANs described by two VLAN numbers, the lesser one first, separated by a hyphen.
Defaults
The default encapsulation is negotiate.
VLAN 1 is the default native VLAN ID on the port.
The default for all VLAN lists is to include all VLANs.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
Encapsulation:
- The switchport trunk encapsulation command is supported only for platforms and interface hardware that can support both ISL and IEEE 802.1Q formats.
- You cannot configure one end of the trunk as an IEEE 802.1Q trunk and the other end as an ISL or nontrunk port. However, you can configure one port as an ISL trunk and a different port on the same switch as an IEEE 802.1Q trunk.
- If you enter the negotiate keywords and DTP negotiation does not resolve the encapsulation format, ISL is the selected format. The no form of the command resets the trunk encapsulation format to the default.
- The no form of the encapsulation command res ets the encapsulation format to the default.
Native VLANs:
- All untagged traffic received on an IEEE 802.1Q trunk port is forwarded with the native VLAN configured for the port.
- If a packet has a VLAN ID that is the same as the sending-port native VLAN ID, the packet is sent without a tag; otherwise, the switch sends the packet with a tag.
- The no form of the native vlan command res ets the native mode VLAN to the appropriate default VLAN for the device.
Allowed VLAN:
- To reduce the risk of spanning-tree loops or storms, you can disable VLAN 1 on any individual VLAN trunk port by removing VLAN 1 from the allowed list. When you remove VLAN 1 from a trunk port, the interface continues to send and receive management traffic, for example, Cisco Discovery Protocol (CDP), Port Aggregation Protocol (PAgP), Link Aggregation Control Protocol (LACP), Dynamic Trunking Protocol (DTP), and VLAN Trunking Protocol (VTP) in VLAN 1.
- The no form of the allowed vlan command resets the list to the default list, which allows all VLANs.
Trunk pruning:
- The pruning-eligible list applies only to trunk ports.
- Each trunk port has its own eligibility list.
- If you do not want a VLAN to be pruned, remove it from the pruning-eligible list. VLANs that are pruning-ineligible receive flooded traffic.
- VLAN 1, VLANs 1002 to 1005, and extended-range VLANs (VLANs 1006 to 4094) cannot be pruned.
Examples
This example shows how to cause a port configured as a switched interface to encapsulate in IEEE 802.1Q trunking format regardless of its default trunking format in trunking mode:
Switch(config)# interface gigabitethernet1/0/2
Switch(config-if)# switchport trunk encapsulation dot1q
This example shows how to configure VLAN 3 as the default for the port to send all untagged traffic:
Switch(config)# interface gigabitethernet1/0/2
Switch(config-if)# switchport trunk native vlan 3
This example shows how to add VLANs 1, 2, 5, and 6 to the allowed list:
Switch(config)# interface gigabitethernet1/0/2
Switch(config-if)# switchport trunk allowed vlan add 1,2,5,6
This example shows how to remove VLANs 3 and 10 to 15 from the pruning-eligible list:
Switch(config)# interface gigabitethernet1/0/2
Switch(config-if)# switchport trunk pruning vlan remove 3,10-15
You can verify your settings by entering the show interfaces interface-id switchport privileged EXEC command.
Related Commands
|
|
show interfaces switchport |
Displays the administrative and operational status of a switching (nonrouting) port, including port blocking and port protection settings. |
switchport mode |
Configures the VLAN membership mode of a port. |
switchport voice detect
Use the switchport voice detect interface configuration command on the switch stack or on a standalone switch to detect and recognize a Cisco IP phone. Use the no form of this command to return to the default setting.
switchport voice detect cisco-phone [ full-duplex ]
no switchport voice detect cisco-phone [ full-duplex ]
Note This command is not supported on switches running the LAN base feature set.
Syntax Description
cisco-phone |
Configure the switch to detect and recognize a Cisco IP phone. |
full-duplex |
(optional) Configure the switch to only accept a full-duplex Cisco IP phone. |
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
Use this command to detect and recognize a Cisco IP phone. The Cisco IP phone must be powered by the switch with Power over Ethernet (PoE). If the phone is powered externally, the switch port is disabled.
Examples
This example shows how to enable detection and recognition of a Cisco IP phone on the switch:
Switch(config)# interface gigabitethernet1/0/1
Switch(config-if)# switchport voice detect cisco-phone
This example shows how to disable detection and recognition of a Cisco IP phone on the switch:
Switch(config)# interface gigabitethernet1/0/1
Switch(config-if)# no switchport voice detect cisco-phone
You can verify your settings by entering the show run interfaces interface-id privileged EXEC command.
switchport voice vlan
Use the switchport voice vlan interface configuration command on the switch stack or on a standalone switch to configure voice VLAN on the port. Use the no form of this command to return to the default setting.
switchport voice vlan { vlan-id | dot1p | none | untagged }
no switchport voice vlan
Syntax Description
vlan-id |
Specify the VLAN to be used for voice traffic. The range is 1 to 4094. By default, the IP phone forwards the voice traffic with an IEEE 802.1Q priority of 5. |
dot1p |
Configure the telephone to use IEEE 802.1p priority tagging and uses VLAN 0 (the native VLAN). By default, the Cisco IP phone forwards the voice traffic with an IEEE 802.1p priority of 5. |
none |
Do not instruct the IP telephone about the voice VLAN. The telephone uses the configuration from the telephone key pad. |
untagged |
Configure the telephone to send untagged voice traffic. This is the default for the telephone. |
Defaults
The switch default is not to automatically configure the telephone (none).
The telephone default is not to tag frames.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
You should configure voice VLAN on Layer 2 access ports.
You must enable Cisco Discovery Protocol (CDP) on the switchport connected to the Cisco IP phone for the switch to send configuration information to the phone. CDP is enabled by default globally and on the interface.
Before you enable voice VLAN, we recommend that you enable quality of service (QoS) on the switch by entering the mls qos global configuration command and configure the port trust state to trust by entering the mls qos trust cos interface configuration command.
When you enter a VLAN ID, the IP phone forwards voice traffic in IEEE 802.1Q frames, tagged with the specified VLAN ID. The switch puts IEEE 802.1Q voice traffic in the voice VLAN.
When you select dot1q, none, or untagged, the switch puts the indicated voice traffic in the access VLAN.
In all configurations, the voice traffic carries a Layer 2 IP precedence value. The default is 5 for voice traffic.
When you enable port security on an interface that is also configured with a voice VLAN, set the maximum allowed secure addresses on the port to two. When the port is connected to a Cisco IP phone, the IP phone requires one MAC address. The Cisco IP phone address is learned on the voice VLAN, but is not learned on the access VLAN. If you connect a single PC to the Cisco IP phone, no additional MAC addresses are required. If you connect more than one PC to the Cisco IP phone, you must configure enough secure addresses to allow one for each PC and one for the Cisco IP phone.
If any type of port security is enabled on the access VLAN, dynamic port security is automatically enabled on the voice VLAN.
You cannot configure static secure MAC addresses in the voice VLAN.
A voice-VLAN port cannot be a private-VLAN port.
The Port Fast feature is automatically enabled when voice VLAN is configured. When you disable voice VLAN, the Port Fast feature is not automatically disabled.
Examples
This example shows how to configure VLAN 2 as the voice VLAN for the port:
Switch(config)# interface gigabitethernet1/0/2
Switch(config-if)# switchport voice vlan 2
You can verify your settings by entering the show interfaces interface-id switchport privileged EXEC command.
Related Commands
|
|
show interfaces interface-id switchport |
Displays the administrative and operational status of a switching (nonrouting) port. |
switchport priority extend |
Decides how the device connected to the specified port handles priority traffic received on its incoming port. |
system env temperature threshold yellow
Use the system env temperature threshold yellow global configuration command on the switch stack or on a standalone switch to configure the difference between the yellow and red temperature thresholds that determines the value of yellow threshold. Use the no form of this command to return to the default value.
system env temperature threshold yellow value
no system env temperature threshold yellow value
Syntax Description
value |
Specify the difference between the yellow and red threshold values (in Celsius). The range is 10 to 25. The default value is 14. |
Defaults
These are the default values:
Table 2-56 Default Values for the Temperature Thresholds
|
Difference between Yellow and Red
|
|
Catalyst 3750-X and Catalyst 3560-X |
14°C |
60°C |
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
You cannot configure the green and red thresholds but can configure the yellow threshold. Use the system env temperature threshold yellow value global configuration command to specify the difference between the yellow and red thresholds and to configure the yellow threshold. For example, if the red threshold is 60 degrees C and you want to configure the yellow threshold as 51 degrees C, set the difference between the thresholds as 15 by using the system env temperature threshold yellow 9 command.
Note The internal temperature sensor in the switch measures the internal system temperature and might vary ±5 degrees C.
Examples
This example sets 15 as the difference between the yellow and red thresholds:
Switch(config)# system env temperature threshold yellow 15
Related Commands
|
|
show env temperature status |
Displays the temperature status and threshold levels. |
system mtu
Use the system mtu global configuration command on the switch stack or on a standalone switch to set the maximum packet size or maximum transmission unit (MTU) size for Gigabit Ethernet (10/100/1000) ports, or for 10-Gigabit ports, or for routed ports. Use the no form of this command to restore the global MTU value to its default value. In a mixed hardware stack, you can also configure Fast Ethernet (10/100) ports on Catalyst 3750 members.
system mtu { bytes | jumbo bytes | routing bytes }
no system mtu [ jumbo | routing ]
Syntax Description
bytes |
In a mixed hardware stack, change the MTU size for all Fast Ethernet interfaces on the Catalyst 3750 members. The range is 1500 to 1998 bytes; the default is 1500 bytes. Note This keyword does not apply to Catalyst 3560-X switches. Switch stacks running the LAN base feature set do not support mixed hardware stacks. |
jumbo bytes |
Set the system MTU for Gigabit Ethernet ports and 10-Gigabit Ethernet ports. The system jumbo MTU is the maximum MTU received at the Gigabit Ethernet and 10-Gigabit Ethernet ports. For information about the range for bytes, see Table 2-57 in the “Usage Guidelines” section. |
routing bytes |
Set the maximum MTU for routed packets. You can also set the maximum MTU to be advertised by the routing protocols that support the configured MTU size. The system routing MTU is the maximum MTU for routed packets and is also the maximum MTU that the switch advertises in routing updates for protocols such as OSPF. For information about the range for bytes, see Table 2-57 in the “Usage Guidelines” section. Note This keyword is not supported on switches running the LAN base feature set. |
Defaults
The default MTU size for all ports is 1500 bytes.
The default value for the system routing MTU is the system MTU value.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
The switch does not support the MTU on a per-interface basis.
The system mtu bytes global configuration command only affects the system MTU size on Fast Ethernet ports on Catalyst 3750 members in a mixed hardware switch stack. In this stack, you can use the system mtu bytes global configuration command on a Catalyst 3750-E or Catalyst 3750-X member to configure the system MTU size on a Catalyst 3750 member. If you enter the system mtu bytes global configuration command on a Catalyst 3750-E or a 3560-E switch, the command does not take effect.
The system mtu, system mtu jumbo, and system mtu routing global configuration commands do not take effect in these cases:
- When you enter the system mtu command on a Catalyst 3750-E or 3560-E switch
- In a mixed stack when you enter the system mtu jumbo command for the Fast Ethernet ports on a Catalyst 3750 member
- When you enter the system mtu routing command on a switch on which only Layer 2 ports are configured
Note This command is not supported on switches running the LAN base feature set.
When you use the system mtu bytes or system mtu jumbo bytes command to change the system MTU or system jumbo MTU size, you must reset the switch before the new configuration takes effect. The system mtu routing command does not require a switch reset to take effect.
The system MTU setting is saved in the switch environmental variable in NVRAM and becomes effective when the switch reloads. Unlike the system MTU routing configuration, the MTU settings that you enter with the system mtu and system mtu jumbo commands are not saved in the switch Cisco IOS configuration file, even if you enter the copy running-config startup-config privileged EXEC command. Therefore, if you use TFTP to configure a new switch by using a backup configuration file and want the system MTU to be other than the default, you must explicitly configure the system mtu and system mtu jumbo settings on the new switch and then reload the switch.
The MTU values applied to the stack members depend on the stack configuration:
- A switch stack consisting only of Catalyst 3750-E or Catalyst 3750-X switches
- A switch stack consisting of Catalyst 3750-E or Catalyst 3750-X switches and Catalyst 3750 switches, which can be referred to as a mixed hardware switch stack
- A switch stack consisting only of Catalyst 3750 switches, also referred to as a Catalyst 3750-only switch stack
Table 2-57 shows how the MTU values are applied depending on the configuration.
Table 2-57 System MTU Values
|
|
|
system routing mtu command
|
Standalone Catalyst 3750-X, 3750-E, 3560-X or 3560-E switch or Catalyst 3750-X-only or Catalyst 3750-E-only stack |
You can enter the command on on a Catalyst 3750-X, Catalyst 3750-E, Catalyst 3560-X, or Catalyst 3560-E switch, but system MTU value does not take effect. |
Use the system mtu jumbo bytes command. The range is from 1500 to 9198 bytes. |
Use the system mtu routing bytes command. The range is from 1500 to the system jumbo MTU value (in bytes). |
Mixed hardware stack |
Use the system mtu bytes command, which takes effect only on Catalyst 3750 members. 1 The range is from 1500 to 1998 bytes. |
Use the system mtu jumbo bytes command. The range is from 1500 to 9000 bytes. |
Use the system mtu routing bytes command. The range is from 1500 to the system MTU value (in bytes). 2 |
Catalyst 3750-only stack Catalyst 3750 switch Catalyst 3560 switch |
Use the system mtu bytes command. The range is from 1500 to 1998 bytes. |
Use the system mtu jumbo bytes command. The range is from 1500 to 9000 bytes. |
Use the system mtu routing bytes command. The range is from 1500 to the system MTU value (in bytes). |
The upper limit of the system routing MTU value is based on the switch or switch stack configuration and refers to either the currently applied system MTU or the system jumbo MTU value.
If you enter a value that is outside the allowed range for the specific type of interface, the value is not accepted.
Examples
This example shows how to set the maximum jumbo packet size for Gigabit Ethernet ports to 6000 bytes:
Switch(config)# system mtu jumbo 6000
You can verify your setting by entering the show system mtu privileged EXEC command.
Related Commands
|
|
show system mtu |
Displays the packet size set for Gigabit Ethernet, 10-Gigabit Ethernet, and routed ports. |
test cable-diagnostics tdr
Use the test cable-diagnostics tdr privileged EXEC command on the switch stack or on a standalone switch to run the Time Domain Reflector (TDR) feature on an interface.
test cable-diagnostics tdr interface interface-id
Syntax Description
interface-id |
Specify the interface on which to run TDR. |
Defaults
There is no default.
Command Modes
Privileged EXEC
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
TDR is supported only on 10/100/100 copper Ethernet ports. It is not supported on 10-Gigabit Ethernet ports or small form-factor pluggable (SFP) module ports. For more information about TDR, see the software configuration guide for this release.
After you run TDR by using the test cable-diagnostics tdr interface interface-id command, use the show cable-diagnostics tdr interface interface-id privileged EXEC command to display the results.
Examples
This example shows how to run TDR on an interface:
Switch# test cable-diagnostics tdr interface gigabitethernet1/0/2
TDR test started on interface Gi1/0/2
A TDR test can take a few seconds to run on an interface
Use 'show cable-diagnostics tdr' to read the TDR results.
If you enter the test cable-diagnostics tdr interface interface-id command on an interface that has a link status of up and a speed of 10 or 100 Mb/s, these messages appear:
Switch# test cable-diagnostics tdr interface gigabitethernet1/0/3
TDR test on Gi1/0/9 will affect link state and traffic
TDR test started on interface Gi1/0/3
A TDR test can take a few seconds to run on an interface
Use 'show cable-diagnostics tdr' to read the TDR results.
traceroute mac
Use the traceroute mac privileged EXEC command on the switch stack or on a standalone switch to display the Layer 2 path taken by the packets from the specified source MAC address to the specified destination MAC address.
traceroute mac [ interface interface-id ] { source-mac-address } [ interface interface-id ] { destination-mac-address } [ vlan vlan-id ] [ detail ]
Syntax Description
interface interface-id |
(Optional) Specify an interface on the source or destination switch. |
source-mac-address |
Specify the MAC address of the source switch in hexadecimal format. |
destination-mac-address |
Specify the MAC address of the destination switch in hexadecimal format. |
vlan vlan-id |
(Optional) Specify the VLAN on which to trace the Layer 2 path that the packets take from the source switch to the destination switch. Valid VLAN IDs are 1 to 4094. |
detail |
(Optional) Specify that detailed information appears. |
Defaults
There is no default.
Command Modes
Privileged EXEC
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
For Layer 2 traceroute to function properly, Cisco Discovery Protocol (CDP) must be enabled on all the switches in the network. Do not disable CDP.
When the switch detects a device in the Layer 2 path that does not support Layer 2 traceroute, the switch continues to send Layer 2 trace queries and lets them time out.
The maximum number of hops identified in the path is ten.
Layer 2 traceroute supports only unicast traffic. If you specify a multicast source or destination MAC address, the physical path is not identified, and an error message appears.
The traceroute mac command output shows the Layer 2 path when the specified source and destination addresses belong to the same VLAN. If you specify source and destination addresses that belong to different VLANs, the Layer 2 path is not identified, and an error message appears.
If the source or destination MAC address belongs to multiple VLANs, you must specify the VLAN to which both the source and destination MAC addresses belong. If the VLAN is not specified, the path is not identified, and an error message appears.
The Layer 2 traceroute feature is not supported when multiple devices are attached to one port through hubs (for example, multiple CDP neighbors are detected on a port). When more than one CDP neighbor is detected on a port, the Layer 2 path is not identified, and an error message appears.
This feature is not supported in Token Ring VLANs.
Examples
This example shows how to display the Layer 2 path by specifying the source and destination MAC addresses:
Switch# traceroute mac 0000.0201.0601 0000.0201.0201
Source 0000.0201.0601 found on con6[WS-C3750E-24PD] (2.2.6.6)
con6 (2.2.6.6) :Gi0/0/1 => Gi0/0/3
con5 (2.2.5.5) : Gi0/0/3 => Gi0/0/1
con1 (2.2.1.1) : Gi0/0/1 => Gi0/0/2
con2 (2.2.2.2) : Gi0/0/2 => Gi0/0/1
Destination 0000.0201.0201 found on con2[WS-C3550-24] (2.2.2.2)
This example shows how to display the Layer 2 path by using the detail keyword:
Switch# traceroute mac 0000.0201.0601 0000.0201.0201 detail
Source 0000.0201.0601 found on con6[WS-C3750E-24PD] (2.2.6.6)
con6 / WS-C3750E-24PD / 2.2.6.6 :
Gi0/0/2 [auto, auto] => Gi0/0/3 [auto, auto]
con5 / WS-C2950G-24-EI / 2.2.5.5 :
Fa0/3 [auto, auto] => Gi0/1 [auto, auto]
con1 / WS-C3550-12G / 2.2.1.1 :
Gi0/1 [auto, auto] => Gi0/2 [auto, auto]
con2 / WS-C3550-24 / 2.2.2.2 :
Gi0/2 [auto, auto] => Fa0/1 [auto, auto]
Destination 0000.0201.0201 found on con2[WS-C3550-24] (2.2.2.2)
This example shows how to display the Layer 2 path by specifying the interfaces on the source and destination switches:
Switch# traceroute mac interface fastethernet0/1 0000.0201.0601 interface fastethernet0/3 0000.0201.0201
Source 0000.0201.0601 found on con6[WS-C3750E-24PD] (2.2.6.6)
con6 (2.2.6.6) :Gi0/0/1 => Gi0/0/3
con5 (2.2.5.5) : Gi0/0/3 => Gi0/0/1
con1 (2.2.1.1) : Gi0/0/1 => Gi0/0/2
con2 (2.2.2.2) : Gi0/0/2 => Gi0/0/1
Destination 0000.0201.0201 found on con2[WS-C3550-24] (2.2.2.2)
This example shows the Layer 2 path when the switch is not connected to the source switch:
Switch# traceroute mac 0000.0201.0501 0000.0201.0201 detail
Source not directly connected, tracing source.....
Source 0000.0201.0501 found on con5[WS-C3750E-24TD] (2.2.5.5)
con5 / WS-C3750E-24TD / 2.2.5.5 :
Gi0/0/1 [auto, auto] => Gi0/0/3 [auto, auto]
con1 / WS-C3550-12G / 2.2.1.1 :
Gi0/1 [auto, auto] => Gi0/2 [auto, auto]
con2 / WS-C3550-24 / 2.2.2.2 :
Gi0/2 [auto, auto] => Fa0/1 [auto, auto]
Destination 0000.0201.0201 found on con2[WS-C3550-24] (2.2.2.2)
This example shows the Layer 2 path when the switch cannot find the destination port for the source MAC address:
Switch# traceroute mac 0000.0011.1111 0000.0201.0201
Error:Source Mac address not found.
This example shows the Layer 2 path when the source and destination devices are in different VLANs:
Switch# traceroute mac 0000.0201.0601 0000.0301.0201
Error:Source and destination macs are on different vlans.
This example shows the Layer 2 path when the destination MAC address is a multicast address:
Switch# traceroute mac 0000.0201.0601 0100.0201.0201
Invalid destination mac address
This example shows the Layer 2 path when source and destination switches belong to multiple VLANs:
Switch# traceroute mac 0000.0201.0601 0000.0201.0201
Error:Mac found on multiple vlans.
Related Commands
|
|
traceroute mac ip |
Displays the Layer 2 path taken by the packets from the specified source IP address or hostname to the specified destination IP address or hostname. |
traceroute mac ip
Use the traceroute mac ip privileged EXEC command on the switch stack or on a standalone switch to display the Layer 2 path taken by the packets from the specified source IP address or hostname to the specified destination IP address or hostname.
traceroute mac ip { source-ip-address | source-hostname } { destination-ip-address | destination-hostname } [ detail ]
Syntax Description
source-ip-address |
Specify the IP address of the source switch as a 32-bit quantity in dotted-decimal format. |
destination-ip-address |
Specify the IP address of the destination switch as a 32-bit quantity in dotted-decimal format. |
source-hostname |
Specify the IP hostname of the source switch. |
destination-hostname |
Specify the IP hostname of the destination switch. |
detail |
(Optional) Specify that detailed information appears. |
Defaults
There is no default.
Command Modes
Privileged EXEC
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
For Layer 2 traceroute to function properly, Cisco Discovery Protocol (CDP) must be enabled on all the switches in the network. Do not disable CDP.
When the switch detects an device in the Layer 2 path that does not support Layer 2 traceroute, the switch continues to send Layer 2 trace queries and lets them time out.
The maximum number of hops identified in the path is ten.
The traceroute mac ip command output shows the Layer 2 path when the specified source and destination IP addresses are in the same subnet. When you specify the IP addresses, the switch uses Address Resolution Protocol (ARP) to associate the IP addresses with the corresponding MAC addresses and the VLAN IDs.
- If an ARP entry exists for the specified IP address, the switch uses the associated MAC address and identifies the physical path.
- If an ARP entry does not exist, the switch sends an ARP query and tries to resolve the IP address. The IP addresses must be in the same subnet. If the IP address is not resolved, the path is not identified, and an error message appears.
The Layer 2 traceroute feature is not supported when multiple devices are attached to one port through hubs (for example, multiple CDP neighbors are detected on a port). When more than one CDP neighbor is detected on a port, the Layer 2 path is not identified, and an error message appears.
This feature is not supported in Token Ring VLANs.
Examples
This example shows how to display the Layer 2 path by specifying the source and destination IP addresses and by using the detail keyword:
Switch# traceroute mac ip 2.2.66.66 2.2.22.22 detail
Translating IP to mac.....
2.2.66.66 => 0000.0201.0601
2.2.22.22 => 0000.0201.0201
Source 0000.0201.0601 found on con6[WS-C2950G-24-EI] (2.2.6.6)
con6 / WS-C3750E-24TD / 2.2.6.6 :
Gi0/0/1 [auto, auto] => Gi0/0/3 [auto, auto]
con5 / WS-C2950G-24-EI / 2.2.5.5 :
Fa0/3 [auto, auto] => Gi0/1 [auto, auto]
con1 / WS-C3550-12G / 2.2.1.1 :
Gi0/1 [auto, auto] => Gi0/2 [auto, auto]
con2 / WS-C3550-24 / 2.2.2.2 :
Gi0/2 [auto, auto] => Fa0/1 [auto, auto]
Destination 0000.0201.0201 found on con2[WS-C3550-24] (2.2.2.2)
This example shows how to display the Layer 2 path by specifying the source and destination hostnames:
Switch# traceroute mac ip con6 con2
Translating IP to mac.....
2.2.66.66 => 0000.0201.0601
2.2.22.22 => 0000.0201.0201
Source 0000.0201.0601 found on con6
con6 (2.2.6.6) :Gi0/0/1 => Gi0/0/3
con5 (2.2.5.5) : Gi0/0/3 => Gi0/1
con1 (2.2.1.1) : Gi0/0/1 => Gi0/2
con2 (2.2.2.2) : Gi0/0/2 => Fa0/1
Destination 0000.0201.0201 found on con2
This example shows the Layer 2 path when ARP cannot associate the source IP address with the corresponding MAC address:
Switch# traceroute mac ip 2.2.66.66 2.2.77.77
Arp failed for destination 2.2.77.77.
Related Commands
|
|
traceroute mac |
Displays the Layer 2 path taken by the packets from the specified source MAC address to the specified destination MAC address. |
trust
Use the trust policy-map class configuration command on the switch stack or on a standalone switch to define a trust state for traffic classified through the class policy-map configuration or the class-map global configuration command. Use the no form of this command to return to the default setting.
trust [ cos | dscp | ip-precedence ]
no trust [ cos | dscp | ip-precedence ]
Syntax Description
cos |
(Optional) Classify an ingress packet by using the packet class of service (CoS) value. For an untagged packet, the port default CoS value is used. |
dscp |
(Optional) Classify an ingress packet by using the packet Differentiated Services Code Point (DSCP) values (most significant 6 bits of 8-bit service-type field). For a non-IP packet, the packet CoS value is used if the packet is tagged. If the packet is untagged, the default port CoS value is used to map CoS to DSCP. |
ip-precedence |
(Optional) Classify an ingress packet by using the packet IP-precedence value (most significant 3 bits of 8-bit service-type field). For a non-IP packet, the packet CoS value is used if the packet is tagged. If the packet is untagged, the port default CoS value is used to map CoS to DSCP. |
Defaults
The action is not trusted. If no keyword is specified when the command is entered, the default is dscp.
Command Modes
Policy-map class configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
Use this command to distinguish the quality of service (QoS) trust behavior for certain traffic from other traffic. For example, incoming traffic with certain DSCP values can be trusted. You can configure a class map to match and trust the DSCP values in the incoming traffic.
Trust values set with this command supersede trust values set with the mls qos trust interface configuration command.
The trust command is mutually exclusive with set policy-map class configuration command within the same policy map.
If you specify trust cos, QoS uses the received or default port CoS value and the CoS-to-DSCP map to generate a DSCP value for the packet.
If you specify trust dscp, QoS uses the DSCP value from the ingress packet. For non-IP packets that are tagged, QoS uses the received CoS value; for non-IP packets that are untagged, QoS uses the default port CoS value. In either case, the DSCP value for the packet is derived from the CoS-to-DSCP map.
If you specify trust ip-precedence, QoS uses the IP precedence value from the ingress packet and the IP-precedence-to-DSCP map. For non-IP packets that are tagged, QoS uses the received CoS value; for non-IP packets that are untagged, QoS uses the default port CoS value. In either case, the DSCP for the packet is derived from the CoS-to-DSCP map.
To return to policy-map configuration mode, use the exit command. To return to privileged EXEC mode, use the end command.
Examples
This example shows how to define a port trust state to trust incoming DSCP values for traffic classified with class1 :
Switch(config)# policy-map policy1
Switch(config-pmap)# class class1
Switch(config-pmap-c)# trust dscp
Switch(config-pmap-c)# police 1000000 20000 exceed-action policed-dscp-transmit
Switch(config-pmap-c)# exit
You can verify your settings by entering the show policy-map privileged EXEC command.
Related Commands
|
|
class |
Defines a traffic classification match criteria (through the police, set, and trust policy-map class configuration commands) for the specified class-map name. |
police |
Defines a policer for classified traffic. |
policy-map |
Creates or modifies a policy map that can be attached to multiple ports to specify a service policy. |
set |
Classifies IP traffic by setting a DSCP or IP-precedence value in the packet. |
show policy-map |
Displays QoS policy maps. |
udld
Use the udld global configuration command on the switch stack or on a standalone switch to enable aggressive or normal mode in the UniDirectional Link Detection (UDLD) and to set the configurable message timer time. Use the no form of the command to disable aggressive or normal mode UDLD on all fiber-optic ports.
udld { aggressive | enable | message time message-timer-interval }
no udld { aggressive | enable | message }
Syntax Description
aggressive |
Enable UDLD in aggressive mode on all fiber-optic interfaces. |
enable |
Enable UDLD in normal mode on all fiber-optic interfaces. |
message time message-timer-interval |
Configure the period of time between UDLD probe messages on ports that are in the advertisement phase and are determined to be bidirectional. The range is 1 to 90 seconds. The default is 15 seconds. |
Defaults
UDLD is disabled on all interfaces.
The message timer is set at 15 seconds.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
UDLD supports two modes of operation: normal (the default) and aggressive. In normal mode, UDLD detects unidirectional links due to misconnected interfaces on fiber-optic connections. In aggressive mode, UDLD also detects unidirectional links due to one-way traffic on fiber-optic and twisted-pair links and due to misconnected interfaces on fiber-optic links. For information about normal and aggressive modes, see the “Understanding UDLD” section in the software configuration guide for this release.
If you change the message time between probe packets, you are making a trade-off between the detection speed and the CPU load. By decreasing the time, you can make the detection-response faster but increase the load on the CPU.
This command affects fiber-optic interfaces only. Use the udld interface configuration command to enable UDLD on other interface types.
You can use these commands to reset an interface shut down by UDLD:
- The udld reset privileged EXEC command to reset all interfaces shut down by UDLD
- The shutdown and no shutdown interface configuration commands
- The no udld enable global configuration command followed by the udld { aggressive | enable } global configuration command to re-enable UDLD globally
- The no udld port interface configuration command followed by the udld port or udld port aggressive interface configuration command to re-enable UDLD on the specified interface
- The errdisable recovery cause udld and errdisable recovery interval interval global configuration commands to automatically recover from the UDLD error-disabled state
Examples
This example shows how to enable UDLD on all fiber-optic interfaces:
Switch(config)# udld enable
You can verify your setting by entering the show udld privileged EXEC command.
Related Commands
|
|
show udld |
Displays UDLD administrative and operational status for all ports or the specified port. |
udld port |
Enables UDLD on an individual interface or prevents a fiber-optic interface from being enabled by the udld global configuration command. |
udld reset |
Resets all interfaces shut down by UDLD and permits traffic to again pass through. |
udld port
Use the udld port interface configuration command on the switch stack or on a standalone switch to enable the UniDirectional Link Detection (UDLD) on an individual interface or prevent a fiber-optic interface from being enabled by the udld global configuration command. Use the no form of this command to return to the udld global configuration command setting or to disable UDLD if entered for a nonfiber-optic port.
udld port [ aggressive ]
no udld port [ aggressive ]
Syntax Description
aggressive |
Enable UDLD in aggressive mode on the specified interface. |
Defaults
On fiber-optic interfaces, UDLD is not enabled, not in aggressive mode, and not disabled. For this reason, fiber-optic interfaces enable UDLD according to the state of the udld enable or udld aggressive global configuration command.
On nonfiber-optic interfaces, UDLD is disabled.
Command Modes
Interface configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
A UDLD-capable port cannot detect a unidirectional link if it is connected to a UDLD-incapable port of another switch.
UDLD supports two modes of operation: normal (the default) and aggressive. In normal mode, UDLD detects unidirectional links due to misconnected interfaces on fiber-optic connections. In aggressive mode, UDLD also detects unidirectional links due to one-way traffic on fiber-optic and twisted-pair links and due to misconnected interfaces on fiber-optic links. For information about normal and aggressive modes, see the “Configuring UDLD” chapter in the software configuration guide for this release.
To enable UDLD in normal mode, use the udld port interface configuration command. To enable UDLD in aggressive mode, use the udld port aggressive interface configuration command.
Use the no udld port command on fiber-optic ports to return control of UDLD to the udld enable global configuration command or to disable UDLD on nonfiber-optic ports.
Use the udld port aggressive command on fiber-optic ports to override the setting of the udld enable or udld aggressive global configuration command. Use the no form on fiber-optic ports to remove this setting and to return control of UDLD enabling to the udld global configuration command or to disable UDLD on nonfiber-optic ports.
You can use these commands to reset an interface shut down by UDLD:
- The udld reset privileged EXEC command to reset all interfaces shut down by UDLD
- The shutdown and no shutdown interface configuration commands
- The no udld enable global configuration command followed by the udld { aggressive | enable } global configuration command to re-enable UDLD globally
- The no udld port interface configuration command followed by the udld port or udld port aggressive interface configuration command to re-enable UDLD on the specified interface
- The errdisable recovery cause udld and errdisable recovery interval interval global configuration commands to automatically recover from the UDLD error-disabled state
Examples
This example shows how to enable UDLD on an port:
Switch(config)# interface gigabitethernet6/0/1
Switch(config-if)# udld port
This example shows how to disable UDLD on a fiber-optic interface despite the setting of the udld global configuration command:
Switch(config)# interface gigabitethernet6/0/1
Switch(config-if)# no udld port
You can verify your settings by entering the show running-config or the show udld interface privileged EXEC command.
Related Commands
|
|
show running-config |
Displays the operating configuration. For syntax information, use this link to the Cisco IOS Release 12.2 Command Reference listing page: http://www.cisco.com/en/US/products/sw/iosswrel/ps1835/prod_command_reference_list.html Select the Cisco IOS Commands Master List, Release 12.2 to navigate to the command. |
show udld |
Displays UDLD administrative and operational status for all ports or the specified port. |
udld |
Enables aggressive or normal mode in UDLD or sets the configurable message timer time. |
udld reset |
Resets all interfaces shut down by UDLD and permits traffic to again pass through. |
udld reset
Use the udld reset privileged EXEC command to reset all interfaces disabled by the UniDirectional Link Detection (UDLD) and permit traffic to begin passing through them again (though other features, such as spanning tree, Port Aggregation Protocol (PAgP), and Dynamic Trunking Protocol (DTP) still have their normal effects, if enabled).
udld reset
Syntax Description
This command has no arguments or keywords.
Command Modes
Privileged EXEC
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
If the interface configuration is still enabled for UDLD, these ports begin to run UDLD again and are disabled for the same reason if the problem has not been corrected.
Examples
This example shows how to reset all interfaces disabled by UDLD:
1 ports shutdown by UDLD were reset.
You can verify your setting by entering the show udld privileged EXEC command.
Related Commands
|
|
show running-config |
Displays the operating configuration. For syntax information, use this link to the Cisco IOS Release 12.2 Command Reference listing page: http://www.cisco.com/en/US/products/sw/iosswrel/ps1835/prod_command_reference_list.html Select the Cisco IOS Commands Master List, Release 12.2 to navigate to the command. |
show udld |
Displays UDLD administrative and operational status for all ports or the specified port. |
udld |
Enables aggressive or normal mode in UDLD or sets the configurable message timer time. |
udld port |
Enables UDLD on an individual interface or prevents a fiber-optic interface from being enabled by the udld global configuration command. |
usb-inactivity-timeout
To configure an inactivity timeout on the USB console, use the usb-inactivity-timeout command in console line configuration mode. To remove the inactivity timeout use the no form of this command.
usb-inactivity-timeout minutes
no usb-inactivity-timeout minutes
Syntax Description
minutes |
Time, in minutes, before the console port changes to the RJ-45 port due to inactivity on the USB console. The range is 1 to 240. The default is no timeout. |
Defaults
Inactivity timeout is not configured.
Command Modes
Line configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
The switch has a configurable timeout inactivity that activates the RJ-45 console if the USB console has been activated but no input activity has occurred on the USB console for a specified time period. When the USB console is deactivated due to an inactivity timeout, you can restore its operation by disconnecting and reconnecting the USB cable.
Examples
This example shows how to configure the inactivity timeout:
Switch# configure terminal
Switch(config)# line console 0
Switch(config-line)# usb-inactivity-timeout 60
If there is no input on the USB console for 60 minutes, the console changes to RJ-45, and a system message log appears showing the inactivity timeout.
Related Commands
|
|
no media-type rj45 |
Resets the console port as the USB port if it has been manually set to the RJ-45 port. |
vlan
Use the vlan global configuration command to add a VLAN and to enter the VLAN configuration mode. Use the no form of this command to delete the VLAN. Configuration information for normal-range VLANs (VLAN IDs 1 to 1005) is always saved in the VLAN database. When you are using (VLAN Trunking Protocol (VTP) version 3 or when VTP mode is transparent (VTP version 1 or 2), you can create extended-range VLANs (VLAN IDs greater than 1005). In VTP version 3, these VLANs are also saved in the VLAN database.
vlan vlan-id
no vlan vlan -id
Syntax Description
vlan-id |
ID of the VLAN to be added and configured. For vlan-id, the range is 1 to 4094. You can enter a single VLAN ID, a series of VLAN IDs separated by commas, or a range of VLAN IDs separated by hyphens. |
Defaults
This command has no default settings.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
You use the vlan vlan-id global configuration command to add normal-range VLANs (VLAN IDs 1 t0 1005) or extended-range VLANs (VLAN IDs 1006 to 4094). With VTP version 1 and version 2, before adding extended-range VLANs, you must use the vtp transparent global configuration command to put the switch in VTP transparent mode. With VTP version 1 and 2, extended-range VLANs are not learned by VTP and are not added to the VLAN database. When VTP mode is transparent, VTP mode and domain name and all VLAN configurations are saved in the running configuration, and you can save them in the switch startup configuration file.
VTP version 3 supports propagation of extended-range VLANs and you can create them in VTP server or client mode.
When you save the VLAN and VTP configurations in the startup configuration file and reboot the switch, the configuration is selected in these ways:
- If both the VLAN database and the configuration file show the VTP mode as transparent and the VTP domain names match, the VLAN database is ignored. The VTP and VLAN configurations in the startup configuration file are used. The VLAN database revision number remains unchanged in the VLAN database.
- If the VTP mode is server, or if the startup VTP mode or domain names do not match the VLAN database, the VTP mode and the VLAN configuration for the first 1005 VLANs use the VLAN database information. With VTP version 3, all VLAN-IDs are in the VLAN database.
With VTP version 1 and version 2, if you try to create an extended-range VLAN when the switch is not in VTP transparent mode, the VLAN is rejected, and you receive an error message.
If you enter an invalid VLAN ID, you receive an error message and do not enter config-vlan mode.
Entering the vlan command with a VLAN ID enables config-vlan mode. When you enter the VLAN ID of an existing VLAN, you do not create a new VLAN, but you can modify VLAN parameters for that VLAN. The specified VLANs are added or modified when you exit the config-vlan mode. Only the shutdown command (for VLANs 1 to 1005) takes effect immediately.
These configuration commands are available in config-vlan mode. The no form of each command returns the characteristic to its default state.
Note Although all commands are visible, the only VLAN configuration commands that are supported on extended-range VLANs are mtu mtu-size, private-vlan, and remote-span. For extended-range VLANs, all other characteristics must remain at the default state.
- are are-number : defines the maximum number of all-routes explorer (ARE) hops for this VLAN. This keyword applies only to TrCRF VLANs.The range is 0 to 13. The default is 7. If no value is entered, 0 is assumed to be the maximum.
- backupcrf : specifies the backup CRF mode. This keyword applies only to TrCRF VLANs.
– enable backup CRF mode for this VLAN.
– disable backup CRF mode for this VLAN (the default).
- bridge { bridge-number| type }: specifies the logical distributed source-routing bridge, the bridge that interconnects all logical rings having this VLAN as a parent VLAN in FDDI-NET, Token Ring-NET, and TrBRF VLANs. The range is 0 to 15. The default bridge number is 0 (no source-routing bridge) for FDDI-NET, TrBRF, and Token Ring-NET VLANs. The type keyword applies only to TrCRF VLANs and is one of these:
– srb (source-route bridging)
– srt (source-route transparent) bridging VLAN
- exit : applies changes, increments the VLAN database revision number (VLANs 1 to 1005 only), and exits config-vlan mode.
- media : defines the VLAN media type. See Table 2-58 for valid commands and syntax for different media types.
Note The switch supports only Ethernet ports. You configure only FDDI and Token Ring media-specific characteristics for VLAN Trunking Protocol (VTP) global advertisements to other switches. These VLANs are locally suspended.
– ethernet is Ethernet media type (the default).
– fddi is FDDI media type.
– fd-net is FDDI network entity title (NET) media type.
– tokenring is Token Ring media type if the VTP v2 mode is disabled, or TrCRF if the VTP Version 2 (v) mode is enabled.
– tr-net is Token Ring network entity title (NET) media type if the VTP v2 mode is disabled or TrBRF media type if the VTP v2 mode is enabled.
- mtu mtu-size : specifies the maximum transmission unit (MTU) (packet size in bytes). The range is 1500 to 18190. The default is 1500 bytes.
- name vlan-name : names the VLAN with an ASCII string from 1 to 32 characters that must be unique within the administrative domain. The default is VLANxxxx where xxxx represents four numeric digits (including leading zeros) equal to the VLAN ID number.
- no : negates a command or returns it to the default setting.
- parent parent-vlan-id : specifies the parent VLAN of an existing FDDI, Token Ring, or TrCRF VLAN. This parameter identifies the TrBRF to which a TrCRF belongs and is required when defining a TrCRF. The range is 0 to 1005. The default parent VLAN ID is 0 (no parent VLAN) for FDDI and Token Ring VLANs. For both Token Ring and TrCRF VLANs, the parent VLAN ID must already exist in the database and be associated with a Token Ring-NET or TrBRF VLAN.
- private-vlan : configure the VLAN as a private VLAN community, isolated, or primary VLAN or configure the association between private-VLAN primary and secondary VLANs. For more information, see the private-vlan command.
- remote-span : configure the VLAN as a Remote SPAN (RSPAN) VLAN. When the RSPAN feature is added to an existing VLAN, the VLAN is first deleted and is then recreated with the RSPAN feature. Any access ports are deactivated until the RSPAN feature is removed. If VTP is enabled, the new RSPAN VLAN is propagated by VTP for VLAN-IDs that are lower than 1024. Learning is disabled on the VLAN. See the remote-span command for more information.
- ring ring-number : defines the logical ring for an FDDI, Token Ring, or TrCRF VLAN. The range is 1 to 4095. The default for Token Ring VLANs is 0. For FDDI VLANs, there is no default.
- said said-value : specifies the security association identifier (SAID) as documented in IEEE 802.10. The range is 1 to 4294967294, and the number must be unique within the administrative domain. The default value is 100000 plus the VLAN ID number.
- shutdown : shuts down VLAN switching on the VLAN. This command takes effect immediately. Other commands take effect when you exit config-vlan mode.
- state : specifies the VLAN state:
– active means the VLAN is operational (the default).
– suspend means the VLAN is suspended. Suspended VLANs do not pass packets.
- ste ste-number : defines the maximum number of spanning-tree explorer (STE) hops. This keyword applies only to TrCRF VLANs. The range is 0 to 13. The default is 7.
- stp type : defines the spanning-tree type for FDDI-NET, Token Ring-NET, or TrBRF VLANs. For FDDI-NET VLANs, the default STP type is ieee. For Token Ring-NET VLANs, the default STP type is ibm. For FDDI and Token Ring VLANs, the default is no type specified.
– ieee for IEEE Ethernet STP running source-route transparent (SRT) bridging.
– ibm for IBM STP running source-route bridging (SRB).
– auto for STP running a combination of source-route transparent bridging (IEEE) and source-route bridging (IBM).
- tb-vlan1 tb-vlan1-id and tb-vlan2 tb-vlan2-id : specifies the first and second VLAN to which this VLAN is translationally bridged. Translational VLANs translate FDDI or Token Ring to Ethernet, for example. The range is 0 to 1005. If no value is specified, 0 (no transitional bridging) is assumed.
Table 2-58 Valid Commands and Syntax for Different Media Types
|
|
Ethernet |
name vlan-name, media ethernet, state {suspend | active}, said said-value, mtu mtu-size, remote-span, tb-vlan1 tb-vlan1-id, tb-vlan2 tb-vlan2-id |
FDDI |
name vlan-name, media fddi, state {suspend | active}, said said-value, mtu mtu-size, ring ring-number, parent parent-vlan-id, tb-vlan1 tb-vlan1-id, tb-vlan2 tb-vlan2-id |
FDDI-NET |
name vlan-name, media fd-net, state {suspend | active}, said said-value, mtu mtu-size, bridge bridge-number, stp type {ieee | ibm | auto}, tb-vlan1 tb-vlan1-id, tb-vlan2 tb-vlan2-id If VTP v2 mode is disabled, do not set the stp type to auto. |
Token Ring |
VTP v1 mode is enabled. name vlan-name, media tokenring, state {suspend | active}, said said-value, mtu mtu-size, ring ring-number, parent parent-vlan-id, tb-vlan1 tb-vlan1-id, tb-vlan2 tb-vlan2-id |
Token Ring concentrator relay function (TrCRF) |
VTP v2 mode is enabled. name vlan-name, media tokenring, state {suspend | active}, said said-value, mtu mtu-size, ring ring-number, parent parent-vlan-id, bridge type {srb | srt}, are are-number, ste ste-number, backupcrf {enable | disable}, tb-vlan1 tb-vlan1-id, tb-vlan2 tb-vlan2-id |
Token Ring-NET |
VTP v1 mode is enabled. name vlan-name, media tr-net, state {suspend | active}, said said-value, mtu mtu-size, bridge bridge-number, stp type {ieee | ibm}, tb-vlan1 tb-vlan1-id, tb-vlan2 tb-vlan2-id |
Token Ring bridge relay function (TrBRF) |
VTP v2 mode is enabled. name vlan-name, media tr-net, state {suspend | active}, said said-value, mtu mtu-size, bridge bridge-number, stp type {ieee | ibm | auto}, tb-vlan1 tb-vlan1-id, tb-vlan2 tb-vlan2-id |
Table 2-59 describes the rules for configuring VLANs.
Table 2-59 VLAN Configuration Rules
|
|
VTP v2 mode is enabled, and you are configuring a TrCRF VLAN media type. |
Specify a parent VLAN ID of a TrBRF that already exists in the database. Specify a ring number. Do not leave this field blank. Specify unique ring numbers when TrCRF VLANs have the same parent VLAN ID. Only one backup concentrator relay function (CRF) can be enabled. |
VTP v2 mode is enabled, and you are configuring VLANs other than TrCRF media type. |
Do not specify a backup CRF. |
VTP v2 mode is enabled, and you are configuring a TrBRF VLAN media type. |
Specify a bridge number. Do not leave this field blank. |
VTP v1 mode is enabled. |
No VLAN can have an STP type set to auto. This rule applies to Ethernet, FDDI, FDDI-NET, Token Ring, and Token Ring-NET VLANs. |
Add a VLAN that requires translational bridging (values are not set to zero). |
The translational bridging VLAN IDs that are used must already exist in the database. The translational bridging VLAN IDs that a configuration points to must also contain a pointer to the original VLAN in one of the translational bridging parameters (for example, Ethernet points to FDDI, and FDDI points to Ethernet). The translational bridging VLAN IDs that a configuration points to must be different media types than the original VLAN (for example, Ethernet can point to Token Ring). If both translational bridging VLAN IDs are configured, these VLANs must be different media types (for example, Ethernet can point to FDDI and Token Ring). |
Examples
This example shows how to add an Ethernet VLAN with default media characteristics. The default includes a vlan-name of VLANxxx, where xxxx represents four numeric digits (including leading zeros) equal to the VLAN ID number. The default media option is ethernet ; the state option is active. The default said-value variable is 100000 plus the VLAN ID; the mtu-size variable is 1500; the stp-type option is ieee. When you enter the exit config-vlan configuration command, the VLAN is added if it did not already exist; otherwise, this command does nothing.
This example shows how to create a new VLAN with all default characteristics and enter config-vlan mode:
Switch(config-vlan)# exit
This example shows how to create a new extended-range VLAN with all the default characteristics, to enter config-vlan mode, and to save the new VLAN in the switch startup configuration file:
Switch(config)# vtp mode transparent
Switch(config)# vlan 2000
Switch# copy running-config startup config
You can verify your setting by entering the show vlan privileged EXEC command.
Related Commands
|
|
show vlan |
Displays the parameters for all configured VLANs or one VLAN (if the VLAN ID or name is specified) in the administrative domain. |
vlan access-map
Use the vlan access-map global configuration command on the switch stack or on a standalone switch to create or modify a VLAN map entry for VLAN packet filtering. This entry changes the mode to the VLAN access-map configuration. Use the no form of this command to delete a VLAN map entry. Use the vlan filter interface configuration command to apply a VLAN map to one or more VLANs.
vlan access-map name [ number ]
no vlan access-map name [ number ]
Note This command is not supported on switches running the LAN base feature set.
Syntax Description
name |
Name of the VLAN map. |
number |
(Optional) The sequence number of the map entry that you want to create or modify (0 to 65535). If you are creating a VLAN map and the sequence number is not specified, it is automatically assigned in increments of 10, starting from 10. This number is the sequence to insert to, or delete from, a VLAN access-map entry. |
Defaults
There are no VLAN map entries and no VLAN maps applied to a VLAN.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
In global configuration mode, use this command to create or modify a VLAN map. This entry changes the mode to VLAN access-map configuration, where you can use the match access-map configuration command to specify the access lists for IP or non-IP traffic to match and use the action command to set whether a match causes the packet to be forwarded or dropped.
In VLAN access-map configuration mode, these commands are available:
- action : sets the action to be taken (forward or drop).
- default : sets a command to its defaults
- exit : exits from VLAN access-map configuration mode
- match : sets the values to match (IP address or MAC address).
- no : negates a command or set its defaults
When you do not specify an entry number (sequence number), it is added to the end of the map.
There can be only one VLAN map per VLAN and it is applied as packets are received by a VLAN.
You can use the no vlan access-map name [ number ] command with a sequence number to delete a single entry.
In global configuration mode, use the vlan filter interface configuration command to apply the map to one or more VLANs.
For more information about VLAN map entries, see the software configuration guide for this release.
Examples
This example shows how to create a VLAN map named vac1 and apply matching conditions and actions to it. If no other entries already exist in the map, this will be entry 10.
Switch(config)# vlan access-map vac1
Switch(config-access-map)# match ip address acl1
Switch(config-access-map)# action forward
This example shows how to delete VLAN map vac1 :
Switch(config)# no vlan access-map vac1
vlan dot1q tag native
Use the vlan dot1q tag native global configuration command on the switch stack or on a standalone switch to enable tagging of native VLAN frames on all IEEE 802.1Q trunk ports. Use the no form of this command to return to the default setting.
vlan dot1q tag native
no vlan dot1q tag native
Note This command is not supported on switches running the LAN base feature set.
Syntax Description
This command has no arguments or keywords.
Defaults
The IEEE 802.1Q native VLAN tagging is disabled.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
When enabled, native VLAN packets going out all IEEE 802.1Q trunk ports are tagged.
When disabled, native VLAN packets going out all IEEE 802.1Q trunk ports are not tagged.
You can use this command with the IEEE 802.1Q tunneling feature. This feature operates on an edge switch of a service-provider network and expands VLAN space by using a VLAN-in-VLAN hierarchy and tagging the tagged packets. You must use IEEE 802.1Q trunk ports for sending packets to the service-provider network. However, packets going through the core of the service-provider network might also be carried on IEEE 802.1Q trunks. If the native VLANs of an IEEE 802.1Q trunks match the native VLAN of a tunneling port on the same switch, traffic on the native VLAN is not tagged on the sending trunk port. This command ensures that native VLAN packets on all IEEE 802.1Q trunk ports are tagged. For more information about IEEE 802.1Q tunneling, see the software configuration guide for this release.
Examples
This example shows how to enable IEEE 802.1Q tagging on native VLAN frames:
Switch# configure terminal
Switch (config)# vlan dot1q tag native
You can verify your settings by entering the show vlan dot1q tag native privileged EXEC command.
Related Commands
|
|
show vlan dot1q tag native |
Displays IEEE 802.1Q native VLAN tagging status. |
vlan filter
Use the vlan filter global configuration command on the switch stack or on a standalone switch to apply a VLAN map to one or more VLANs. Use the no form of this command to remove the map.
vlan filter mapname vlan-list { list | all }
no vlan filter mapname vlan-list { list | all }
Note This command is not supported on switches running the LAN base feature set.
Syntax Description
mapname |
Name of the VLAN map entry. |
list |
The list of one or more VLANs in the form tt, uu-vv, xx, yy-zz, where spaces around commas and dashes are optional. The range is 1 to 4094. |
all |
Remove the filter from all VLANs. |
Defaults
There are no VLAN filters.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
To avoid accidentally dropping too many packets and disabling connectivity in the middle of the configuration process, we recommend that you completely define the VLAN access map before applying it to a VLAN.
For more information about VLAN map entries, see the software configuration guide for this release.
Examples
This example applies VLAN map entry map1 to VLANs 20 and 30:
Switch(config)# vlan filter map1 vlan-list 20, 30
This example shows how to delete VLAN map entry mac1 from VLAN 20:
Switch(config)# no vlan filter map1 vlan-list 20
You can verify your settings by entering the show vlan filter privileged EXEC command.
Related Commands
|
|
show vlan access-map |
Displays information about a particular VLAN access map or all VLAN access maps. |
show vlan filter |
Displays information about all VLAN filters or about a particular VLAN or VLAN access map. |
vlan access-map |
Creates a VLAN map entry for VLAN packet filtering. |
vmps reconfirm (privileged EXEC)
Use the vmps reconfirm privileged EXEC command on the switch stack or on a standalone switch to immediately send VLAN Query Protocol (VQP) queries to reconfirm all dynamic VLAN assignments with the VLAN Membership Policy Server (VMPS).
vmps reconfirm
Syntax Description
This command has no arguments or keywords.
Defaults
No default is defined.
Command Modes
Privileged EXEC
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Examples
This example shows how to immediately send VQP queries to the VMPS:
You can verify your setting by entering the show vmps privileged EXEC command and examining the VMPS Action row of the Reconfirmation Status section. The show vmps command shows the result of the last time the assignments were reconfirmed either because the reconfirmation timer expired or because the vmps reconfirm command was entered.
vmps reconfirm (global configuration)
Use the vmps reconfirm global configuration command on the switch stack or on a standalone switch to change the reconfirmation interval for the VLAN Query Protocol (VQP) client. Use the no form of this command to return to the default setting.
vmps reconfirm interval
no vmps reconfirm
Syntax Description
interval |
Reconfirmation interval for VQP client queries to the VLAN Membership Policy Server (VMPS) to reconfirm dynamic VLAN assignments. The range is 1 to 120 minutes. |
Defaults
The default reconfirmation interval is 60 minutes.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Examples
This example shows how to set the VQP client to reconfirm dynamic VLAN entries every 20 minutes:
Switch(config)# vmps reconfirm 20
You can verify your setting by entering the show vmps privileged EXEC command and examining information in the Reconfirm Interval row.
vmps retry
Use the vmps retry global configuration command on the switch stack or on a standalone switch to configure the per-server retry count for the VLAN Query Protocol (VQP) client. Use the no form of this command to return to the default setting.
vmps retry count
no vmps retry
Syntax Description
count |
Number of attempts to contact the VLAN Membership Policy Server (VMPS) by the client before querying the next server in the list. The range is 1 to 10. |
Defaults
The default retry count is 3.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Examples
This example shows how to set the retry count to 7:
Switch(config)# vmps retry 7
You can verify your setting by entering the show vmps privileged EXEC command and examining information in the Server Retry Count row.
vmps server
Use the vmps server global configuration command on the switch stack or on a standalone switch to configure the primary VLAN Membership Policy Server (VMPS) and up to three secondary servers. Use the no form of this command to remove a VMPS server.
vmps server ipaddress [ primary ]
no vmps server [ ipaddress ]
Syntax Description
ipaddress |
IP address or hostname of the primary or secondary VMPS servers. If you specify a hostname, the Domain Name System (DNS) server must be configured. |
primary |
(Optional) Decides whether primary or secondary VMPS servers are being configured. |
Defaults
No primary or secondary VMPS servers are defined.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
The first server entered is automatically selected as the primary server whether or not primary is entered. The first server address can be overridden by using primary in a subsequent command.
If a member switch in a cluster configuration does not have an IP address, the cluster does not use the VMPS server configured for that member switch. Instead, the cluster uses the VMPS server on the command switch, and the command switch proxies the VMPS requests. The VMPS server treats the cluster as a single switch and uses the IP address of the command switch to respond to requests.
When using the no form without specifying the ipaddress, all configured servers are deleted. If you delete all servers when dynamic-access ports are present, the switch cannot forward packets from new sources on these ports because it cannot query the VMPS.
Examples
This example shows how to configure the server with IP address 191.10.49.20 as the primary VMPS server. The servers with IP addresses 191.10.49.21 and 191.10.49.22 are configured as secondary servers:
Switch(config)# vmps server 191.10.49.20 primary
Switch(config)# vmps server 191.10.49.21
Switch(config)# vmps server 191.10.49.22
This example shows how to delete the server with IP address 191.10.49.21:
Switch(config)# no vmps server 191.10.49.21
You can verify your setting by entering the show vmps privileged EXEC command and examining information in the VMPS Domain Server row.
vtp (global configuration)
Use the vtp global configuration command on the switch stack or on a standalone switch to set or modify the VLAN Trunking Protocol (VTP) configuration characteristics. Use the no form of this command to remove the settings or to return to the default settings.
vtp { domain domain-name | file filename | interface name [ only ] | mode { client | off | server | transparent } [ mst | unknown | vlan ] | password password [ hidden | secret ] | pruning | version number }
no vtp { file | interface | mode [ client | off | server | transparent ] [ mst | unknown | vlan ] | password | pruning | version }
Syntax Description
domain domain-name |
Specify the VTP domain name, an ASCII string from 1 to 32 characters that identifies the VTP administrative domain for the switch. The domain name is case sensitive. |
file filename |
Specify the Cisco IOS file system file where the VTP VLAN configuration is stored. |
interface name |
Specify the name of the interface providing the VTP ID updated for this device. |
only |
(Optional) Use only the IP address of this interface as the VTP IP updater. |
mode |
Specify the VTP device mode as client, server, or transparent. |
client |
Place the switch in VTP client mode. A switch in VTP client mode is enabled for VTP, and can send advertisements, but does not have enough nonvolatile storage to store VLAN configurations. You cannot configure VLANs on the switch. When a VTP client starts up, it does not send VTP advertisements until it receives advertisements to initialize its VLAN database. |
off |
Place the switch in VTP off mode. A switch in off VTP off mode functions the same as a VTP transparent device except that it does not forward VTP advertisements on trunk ports. |
server |
Place the switch in VTP server mode. A switch in VTP server mode is enabled for VTP and sends advertisements. You can configure VLANs on the switch. The switch can recover all the VLAN information in the current VTP database from nonvolatile storage after reboot. |
transparent |
Place the switch in VTP transparent mode. A switch in VTP transparent mode is disabled for VTP, does not send advertisements or learn from advertisements sent by other devices, and cannot affect VLAN configurations on other devices in the network. The switch receives VTP advertisements and forwards them on all trunk ports except the one on which the advertisement was received. When VTP mode is transparent, the mode and domain name are saved in the switch running configuration file, and you can save them in the switch startup configuration file by entering the copy running-config startup config privileged EXEC command. |
mst |
(Optional) Set the mode for the multiple spanning tree (MST) VTP database (only VTP version 3). |
unknown |
(Optional) Set the mode for unknown VTP databases (only VTP version 3). |
vlan |
(Optional) Set the mode for VLAN VTP database. This is the default (only VTP version 3). |
password password |
Set the administrative domain password for the generation of the 16-byte secret value used in MD5 digest calculation to be sent in VTP advertisements and to validate received VTP advertisements. The password can be an ASCII string from 1 to 32 characters. The password is case sensitive. |
hidden |
(Optional) Specify that the key generated from the password string is saved in the VLAN database file. When the hidden keyword is not specified, the password string is saved in clear text. When the hidden password is entered, you need to reenter the password to issue a command in the domain. This keyword is supported only in VTP version 3. |
secret |
(Optional) Allow the user to directly configure the password secret key (only VTP version 3). |
pruning |
Enable VTP pruning on the switch. |
version number |
Set VTP version to version 1, version 2, or version 3. |
Defaults
The default filename is flash:vlan.dat .
The default mode is server mode and the default database is VLAN.
In VTP version 3, for the MST database, the default mode is transparent.
No domain name or password is defined.
No password is configured.
Pruning is disabled.
The default version is Version 1.
Command Modes
Global configuration
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
When you save VTP mode, domain name, and VLAN configurations in the switch startup configuration file and reboot the switch, the VTP and VLAN configurations are selected by these conditions:
- If both the VLAN database and the configuration file show the VTP mode as transparent and the VTP domain names match, the VLAN database is ignored. The VTP and VLAN configurations in the startup configuration file are used. The VLAN database revision number remains unchanged in the VLAN database.
- If the startup VTP mode is server mode, or the startup VTP mode or domain names do not match the VLAN database, VTP mode and VLAN configuration for the first 1005 VLANs are selected by VLAN database information, and VLANs greater than 1005 are configured from the switch configuration file.
The vtp file filename cannot be used to load a new database; it renames only the file in which the existing database is stored.
Follow these guidelines when configuring a VTP domain name:
- The switch is in the no-management-domain state until you configure a domain name. While in the no-management-domain state, the switch does not send any VTP advertisements even if changes occur to the local VLAN configuration. The switch leaves the no-management-domain state after it receives the first VTP summary packet on any port that is trunking or after you configure a domain name by using the vtp domain command. If the switch receives its domain from a summary packet, it resets its configuration revision number to 0. After the switch leaves the no-management-domain state, it can no be configured to re-enter it until you clear the NVRAM and reload the software.
- Domain names are case-sensitive.
- After you configure a domain name, it cannot be removed. You can only reassign it to a different domain.
Follow these guidelines when setting VTP mode:
- The no vtp mode command returns the switch to VTP server mode.
- The vtp mode server command is the same as no vtp mode except that it does not return an error if the switch is not in client or transparent mode.
- If the receiving switch is in client mode, the client switch changes its configuration to duplicate the configuration of the server. If you have switches in client mode, be sure to make all VTP or VLAN configuration changes on a switch in server mode. If the receiving switch is in server mode or transparent mode, the switch configuration is not changed.
- Switches in transparent mode do not participate in VTP. If you make VTP or VLAN configuration changes on a switch in transparent mode, the changes are not propagated to other switches in the network.
- If you change the VTP or VLAN configuration on a switch that is in server mode, that change is propagated to all the switches in the same VTP domain.
- The vtp mode transparent command disables VTP from the domain but does not remove the domain from the switch.
- In VTP versions 1 and 2, the VTP mode must be transparent for you to add extended-range VLANs or for VTP and VLAN information to be saved in the running configuration file. VTP supports extended-range VLANs in client and server mode and saved them in the VLAN database.
- With VTP versions 1 and 2, if extended-range VLANs are configured on the switch and you attempt to set the VTP mode to server or client, you receive an error message, and the configuration is not allowed. Changing VTP mode is allowed with extended VLANs in VTP version 3.
- The VTP mode must be transparent for you to add extended-range VLANs or for VTP and VLAN information to be saved in the running configuration file.
- VTP can be set to either server or client mode only when dynamic VLAN creation is disabled.
- The vtp mode off command sets the device to off. The no vtp mode off command resets the device to the VTP server mode.
Follow these guidelines when setting a VTP password:
- Passwords are case sensitive. Passwords should match on all switches in the same domain.
- When you use the no vtp password form of the command, the switch returns to the no-password state.
- The hidden and secret keywords are supported only in VTP version 3. If you convert from VTP version 2 to VTP version 3, you must remove the hidden or secret keyword before the conversion.
Follow these guidelines when setting VTP pruning:
- VTP pruning removes information about each pruning-eligible VLAN from VTP updates if there are no stations belonging to that VLAN.
- If you enable pruning on the VTP server, it is enabled for the entire management domain for VLAN IDs 1 to 1005.
- Only VLANs in the pruning-eligible list can be pruned.
- Pruning is supported with VTP Version 1 and Version 2.
Follow these guidelines when setting the VTP version:
- Toggling the Version 2 (v2) mode state modifies parameters of certain default VLANs.
- Each VTP switch automatically detects the capabilities of all the other VTP devices. To use Version 2, all VTP switches in the network must support Version 2; otherwise, you must configure them to operate in VTP Version 1 mode.
- If all switches in a domain are VTP Version 2-capable, you need only to configure Version 2 on one switch; the version number is then propagated to the other Version-2 capable switches in the VTP domain.
- If you are using VTP in a Token Ring environment, VTP Version 2 must be enabled.
- If you are configuring a Token Ring bridge relay function (TrBRF) or Token Ring concentrator relay function (TrCRF) VLAN media type, you must use Version 2.
- If you are configuring a Token Ring or Token Ring-NET VLAN media type, you must use Version 1.
- In VTP version 3, all database VTP information is propagated across the VTP domain, not only VLAN database information.
- Two VTP version 3 regions can only communicate over a VTP version 1 or VTP version 2 region in transparent mode.
You cannot save password, pruning, and version configurations in the switch configuration file.
Examples
This example shows how to rename the filename for VTP configuration storage to vtpfilename :
Switch(config)# vtp file vtpfilename
This example shows how to clear the device storage filename:
Switch(config)# no vtp file vtpconfig
Clearing device storage filename.
This example shows how to specify the name of the interface providing the VTP updater ID for this device:
Switch(config)# vtp interface gigabitethernet
This example shows how to set the administrative domain for the switch:
Switch(config)# vtp domain OurDomainName
This example shows how to place the switch in VTP transparent mode:
Switch(config)# vtp mode transparent
This example shows how to configure the VTP domain password:
Switch(config)# vtp password ThisIsOurDomain’sPassword
This example shows how to enable pruning in the VLAN database:
Switch(config)# vtp pruning
This example shows how to enable Version 2 mode in the VLAN database:
Switch(config)# vtp version 2
You can verify your settings by entering the show vtp status privileged EXEC command.
Related Commands
|
|
show vtp status |
Displays the VTP statistics for the switch and general information about the VTP management domain status. |
vtp (interface configuration) |
Enables or disables VTP on an interface. |
vtp (interface configuration)
Use the vtp interface configuration command to enable the VLAN Trunking Protocol (VTP) on a per-port basis. Use the no form of this command to disable VTP on the interface.
vtp
no vtp
Note This command is supported only when the switch is running VTP version 3.
Syntax Description
This command has no keywords or arguments.
Command Default
This command has no default settings.
Command Modes
Interface configuration.
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
Enter this command only interfaces that are switchport in trunk mode.
This command is supported only on switches configured for VTP version 3.
Examples
This example shows how to enable VTP on an interface:
This example shows how to disable VTP on an interface:
Switch(config-if)# no vtp
vtp primary
Use the vtp primary privileged EXEC command to configure a switch as the VLAN Trunking Protocol (VTP) primary server.
vtp primary [ mst | vlan ] [ force ]
There is no no form of the command.
Note This command is supported only when the switch is running VTP version 3.
Note Although visible in the command line help, the vtp {password password | pruning | version number} commands are not supported.
Syntax Description
mst |
(Optional) Configure the switch as the primary VTP server for the multiple spanning tree (MST) feature. |
vlan |
(Optional) Configure the switch as the primary VTP server for VLANs. |
force |
(Optional) Configure the switch to not check for conflicting devices when configuring the primary server. |
Defaults
The switch is a VTP secondary server.
Command Modes
Privileged EXEC
Command History
|
|
12.2(53)SE2 |
This command was introduced. |
Usage Guidelines
This command is supported only on switches configured for VTP version 3.
A VTP primary server updates the database information and sends updates that are honored by all devices in the system. A VTP secondary server can only back up the updated VTP configurations received from the primary server to NVRAM.
By default, all devices come up as secondary servers. Primary server status is needed only for database updates when the administrator issues a takeover message in the domain. You can have a working VTP domain without any primary servers.
Primary server status is lost if the device reloads or domain parameters change.
Examples
This example shows how to configure the switch as the primary VTP server for VLANs:
Setting device to VTP TRANSPARENT mode.
You can verify your settings by entering the show vtp status privileged EXEC command.
Related Commands
|
|
show vtp status |
Displays the VTP statistics for the switch and general information about the VTP management domain status. |
vtp (global configuration) |
Configures the VTP filename, interface, domain name, mode, and version. |