Introduction to
External Connectivity
Before you begin—Ensure you know about Programmable Fabric. Conceptual information is covered in the Introduction to Cisco Programmable Fabric and Introducing Cisco Programmable Fabric (VXLAN/EVPN) chapters. Forwarding Configurations chapter contains Virtual Extensible LAN (VXLAN) BGP EVPN fabric configurations, and the IP Fabric Underlay chapter contains unicast and multicast protocol configuration information for the fabric underlay.
VXLAN BGP EVPN fabric supports external connectivity, in that VXLAN BGP EVPN fabric data centers in different sites can be connected using the Data Center Interconnect functionality. Also, VXLAN and non VXLAN pods within a single site can be connected.
You can enable a VXLAN BGP EVPN fabric border leaf switch and an Autonomous System Boundary Router (ASBR) at the edge of the WAN to exchange reachability routes. This way, reachability information is transported between sites. A route exchange scenario at the border leaf or border spine switch is referred as a handoff scenario.
![]() Note | In this chapter, the focus is on the border leaf switch that acts as a borderPE switch (a border leaf switch with integrated MPLS PE functionality) instead of a border spine switch. |
The Cisco Nexus 7000 Series switch is the primary border leaf platform for connecting a VXLAN BGP EVPN fabric to external entities since this switch, with F3 and M3 line cards, acts as the borderPE switch, and provides the combined functionality of a border leaf switch and datacenter edge device. Also, the Cisco Nexus 7000 Series switch provides higher route and VRF scaling capabilities that are required for a border leaf switch.
Points to consider for connecting two data centers:
-
If you want to connect two data center fabrics, restrict the overlay within a data center. Connect two data center instances with an inter data center instance. This way, any instability in one data center will not be spread to the other. Failures can be contained since we are separating the administrative domains.
-
For example, two VXLAN fabrics in different sites are two separate domains, and the MPLS L3VPN inter data center instance forms a different, connecting domain. Here, traffic from the source data center terminates at the border leaf or borderPE switch, and a new Layer-3 inter data center instance sends the traffic to the border leaf switch or borderPE switch of the target datacenter.
-
-
You can create a Layer-2 (OTV, etc) or Layer-3 (LISP, Multiprotocol Label Switching [MPLS] L3VPN, etc) inter datacenter instance.
Layer-3 handoff scenario using MPLS L3VPN is explained in this chapter.
External Connectivity
Layer 3 hand off scenario – MPLS L3VPN
The VXLAN BGP EVPN data center fabric can be connected across Layer-3 boundaries (to external sites and back) using MPLS L3VPN, VRF IP Routing (VRF Lite), or LISP as the mechanism of transport outside the VXLAN fabric.
Cisco Nexus 7000 Series is considered as the border leaf switch in the MPLS L3VPN scenario explained below. For the MPLS handoff scenario, the border leaf switch is referred to as a borderPE switch. In other words, a border leaf switch with integrated MPLS PE functionality is used.
![]() Note | borderPE switch—A Cisco Nexus 7000 Series switch with F3/M3 line cards; acts as the collapsed border leaf switch and MPLS Datacenter Provider Edge router. A BorderPE switch includes MPLS PE function. This is also referred to as a one box solution since a single device provides the combined functionality of a border leaf switch and datacenter Edge device. |
VXLAN BGP EVPN - MPLS L3VPN DCI scenario – In brief
-
Two VXLAN BGP EVPN fabric data centers are depicted at the left and the right of the image (below). Routes within a fabric pod are shared between all VTEPs, including with the Cisco Nexus 7000 Series borderPE switches (that are in a vPC setup).
-
The borderPE switches and the connected Autonomous System Boundary Routers (ASBRs) of the WAN are configured to pass on routes between each other. For example, routes within the VXLAN BGP EVPN fabric (left) are sent to the WAN ASBR, and (necessary) reachability routes within the WAN are sent to the borderPE switch on the VXLAN fabric (left).
-
The WAN ASBR and the VXLAN fabric (right) are also connected in the same way.
-
The WAN ASBRs act as MPLS PE nodes that belong to the WAN autonomous system number (ASN), and this ASN is different than that of the 2 VXLAN BGP EVPN fabrics.
![]() Note | In addition to connecting data center fabrics, these Layer-3 solutions (MPLS L3VPN, VRF Lite, and LISP) are also used to connect campus networks. |

VXLAN BGP EVPN - MPLS L3VPN DCI scenario - In more detail
Route distribution and data flow between the VXLAN pod and the WAN MPLS is explained below.
Route distribution within the VXLAN pod, and subsequent export of VXLAN pod routes to the WAN MPLS
The routes within the VXLAN BGP EVPN pod should be exported to the WAN MPLS, thereby extending Layer-3 reachability from the WAN MPLS to the ToRs within the VXLAN BGP EVPN fabric.
-
The BGP EVPN control plane in the VXLAN BGP EVPN fabric ensures distribution of routes between ToR/leaf switch VTEPs (including the borderPE switch) within the fabric. ToRs will forward the attached end host IP and MAC addresses, /32 (or /128, for IPv6 addresses) ‘Host IP + MAC’ routes, and Layer-2 and Layer-3 VXLAN VNIs using the EVPN Route Type 2/5 option. Based on the import route target (RT) configured on the border leaf switch, the switch will import the /32 (or /128) routes into appropriate VRF tables.
-
The borderPE switch advertises the VRF default route to the ToR/leaf switches. If the ToR/leaf switch nodes receive the same route from multiple borderPE switches, it results in ECMP at the ingress ToR/leaf switch.
-
The borderPE switch should be configured to reoriginate the /32 (or /128) routes on an eBGP VPNv4 session towards the WAN MPLS. The borderPE switch does MPLS switching towards the WAN MPLS and VXLAN BGP EVPN routes are reoriginated into the L3VPN address family.
VXLAN fabric to WAN Data flow—Let us say a host in the VXLAN fabric (left) sends traffic to a host in the other VXLAN fabric (right). A high level data plane flow is depicted below:
-
The VXLAN packet reaches the borderPE switch.
-
A VXLAN VNI lookup happens. This lookup maps to the appropriate bridge domain.
-
The subsequent MAC address lookup points to a bridge domain interface on the borderPE switch, and the packet is bridged to the BDI interface. The BDI interface then points to the corresponding VRF table. 
Note
The BDI is used for VRF routing and has no IP.
-
The destination IP address is checked in the VRF IP table, wherein the corresponding L3VPN MPLS encapsulation towards the WAN MPLS is pointed at.
-
The packet is sent to the WAN ASBR.
Importing of WAN or external routes into the VXLAN BGP EVPN borderPE switch
After WAN or external routes are imported into the borderPE switch, they are re-advertised to the ToR/leaf switches in the VXLAN BGP EVPN fabric with the borderPE VTEP acting as the next hop for the ToR/leaf switches, thereby extending Layer-3 reachability from the ToR/leaf switches to the WAN.
-
The borderPE (Cisco Nexus 7000 Series) switch will function as an EVPN based Layer-3 VXLAN Gateway to provide an overlay routing function for Layer-3 IP traffic between the VXLAN overlay fabric and the WAN. This includes Layer-3 flows between the VPNv4/6 and/or IP end points outside the VXLAN pod (like hosts in the other data center, etc).
-
The borderPE switch receives routes from L3VPN ASBRs to enable connectivity to the WAN. This is achieved through an external BGP VPNv4 or VPNv6 session with the WAN ASBR device. The L3VPN routes from the WAN will be imported into local VRF tables in the borderPE switch.
-
The borderPE switch should be configured to re-originate the L3VPN routes into the EVPN address family so as to send the routes via BGP EVPN control plane from the borderPE switch towards the ToR/leaf switches. The ToR/leaf switches will import these routes into the appropriate VRF.
-
Necessary configuration knobs will need to be added in BGP under VRF, and under neighbor evpn address family to originate a default route towards EVPN neighbors and drop all other routes.
WAN to VXLAN BGP EVPN fabric Data flow—Traffic from the WAN ASBR arrives at the borderPE switch. A high level flow is depicted below:
-
The packet arrives with a local, per VRF VPN label (advertised earlier by the borderPE switch). The MPLS label lookup points to the correct VRF table.
-
The (VRF, IP) lookup results in a /32 (or /128) route that points to the VXLAN tunnel end point adjacency for the ToR/leaf switch VTEP on the fabric facing per VRF BDI interface.
-
The packet is VXLAN encapsulated with the router MAC (RMAC) address of the remote ToR/leaf switch VTEP and sent on the VRF BDI interface.
-
The FIB lookup drives the VXLAN encapsulation towards the designated remote ToR/leaf switch VTEP.
The fabric is stitched to the VPN service
BorderPE switches in a vPC setup
The two borderPE switches are configured as a vPC. In a VXLAN vPC deployment, a common, virtual VTEP IP address (secondary loopback IP address) is used for communication. The common, virtual VTEP uses a system specific router MAC address. The Layer-3 prefixes or default route from the borderPE switch will be advertised with this common virtual VTEP as the next hop, and the ToR/leaf switch VTEPs will install the default route and/or prefix route with a single BGP path to the borderPE common, virtual VTEP IP address.
Advertising primary IP address (PIP)
On a vPC enabled leaf or border leaf switch, by default all Layer-3 routes are advertised with the secondary IP address (VIP) of the leaf switch VTEP as the BGP next-hop IP address. Prefix routes and leaf switch generated routes are not synced between vPC leaf switches. Using the VIP as the BGP next-hop for these types of routes can cause traffic to be forwarded to the wrong vPC leaf or border leaf switch and black-holed. The provision to use the primary IP address (PIP) as the next-hop when advertising prefix routes or loopback interface routes in BGP on vPC enabled leaf or border leaf switches allows users to select the PIP as BGP next-hop when advertising these types of routes, so that traffic will always be forwarded to the right vPC enabled leaf or border leaf switch.
The configuration command for advertising the PIP is advertise-pip.
A sample configuration is given below:
(config) #
router bgp 65536
address-family l2vpn evpn
advertise-pip
advertise-system-mac
BorderPE switch to WAN ASBR link failure scenario
If there is link failure between one of the two borderPE switches and the connected L3VPN ASBR, the switch will withdraw the BGP routes that are being advertised towards the fabric and traffic re-convergence happens through the redundant border leaf switch.
For border leaf switches (in a two box solution), the default route will be withdrawn when both links to the DC Edge router fail. For a borderPE switch, advertising default route is not recommended.
Configuration for the VXLAN BGP EVPN - MPLS L3VPN DCI scenario
The following configurations enabled on the borderPE switch establish a Layer-3 link along with the MPLS/LDP configuration between the borderPE switch and the WAN ASBR. After configurations on the borderPE switch and the WAN ASBR device, routes are exchanged between the VXLAN fabric borderPE switch and the MPLS WAN ASBR.
-
This document only contains Cisco Nexus 7000 Series borderPE switch related configurations. To complete Layer-3 DCI configurations, you should also enable corresponding configurations on the WAN ASBR.
-
To forward traffic across the borderPE switch (from the VXLAN BGP EVPN fabric towards the WAN ASBR and the other way round), the fabric forwarding switch-role border command should be mandatorily configured on the borderPE switch. For the borderPE Layer-3 extension auto configuration feature, use the fabric forwarding switch-role border dci-node command.
-
The physical interface connecting the VXLAN BGP EVPN fabric should be different from the IP/MPLS WAN facing interface. The same physical Layer-3 interface or sub interface should not be used to connect the VXLAN BGP EVPN Fabric and the WAN Core.
-
For an F3 only VDC, the Layer-3 backup link that is used to protect the WAN facing interfaces from failure should not be the peer link or SVI of the VLANs extended over the peer link. A separate Layer-2 interface with a dedicated VLAN/SVI, or a separate Layer-3 interface or sub interface should be used.
-
For an M3-F3 VDC, traffic received from the VXLAN BGP EVPN fabric should not be forwarded to a Layer-3 sub interface. VXLAN terminated traffic can only be forwarded over a Layer-3 physical interface.
(config) #
install feature-set fabric feature-set fabric feature fabric forwarding feature interface-vlan feature ospf (OR feature isis) feature nv overlay feature bgp feature vni nv overlay evpn install feature-set mpls feature-set mpls feature mpls l3vpn feature mpls ldp
To run MPLS on a Cisco Nexus 7000 Series borderPE switch, the MPLS Service Package (MPLS_PKG) Feature License is required. Refer to the Cisco NX-OS Licensing Guide for more details.
![]() Note | The install feature-set fabric command should only be used in the admin VDC. When using a VDC, ensure the VDC is of type F3 or M3, for EVPN. A sample configuration is given below: |
(config) #
vdc BorderPE1 limit-resource module-type f3
(config) #
fabric forwarding anycast-gateway-mac 0202.0002.0002
(config) #
fabric forwarding switch-role border system bridge-domain 2500-3500 system fabric bridge-domain 2500-2999 vni 31000 bridge-domain 2500 member vni 31000
(config) #
vrf context vni-31000
vni 31000
rd auto
address-family ipv4 unicast
route-target import 65551:1
route-target export 65551:1
route-target both auto
route-target both auto evpn
Type exit and configure IPv6 route import/export.
address-family ipv6 unicast
route-target import 65551:1
route-target export 65551:1
route-target both auto
route-target both auto evpn
65551:1 refers to the import/export of WAN routes.
![]() Note | The route target 65551:1 should be the same as the route target configured on the connected WAN ASBR since the importing/exporting of MPLS information is based on this route target |
By using route targets as the glue, the BGP EVPN control plane (in the VXLAN fabric) and the BGP L3VPN control plane (from the fabric to the WAN) are connected. Similarly, for a tenant VRF, the same route target should be enabled on ToR/leaf switches and the border leaf switch(es).
On BorderPE1, configure a bridge domain and BDI for the VRF
(config) #
interface BDI 2500 no shutdown mtu 9192 vrf member vni-31000 no ip redirects ip forward ipv6 address use-link-local-only ipv6 forward no ipv6 redirects
The interface BDI configuration is not required to be configured manually, when the profile vrf-tenant-profile is configured. As soon the VRF context is configured, NX-OS automatically calls the profile vrf-tenant-profile and applies appropriate configurations. vrf-tenant-profile is always added when you deploy the BorderPE switch with POAP from DCNM. The resulting interface BDI configuration can be verified with the show run inter bdi 2500 expand-port-profile command.
The vrf-tenant-profile configuration is given below:
configure profile vrf-tenant-profile vni $vrfSegmentId bridge-domain $bridgeDomainId member vni $vrfSegmentId interface bdi $bridgeDomainId vrf member $vrfName ip forward no ip redirects ipv6 forward ipv6 address use-link-local-only no ipv6 redirects mtu 9192 no shutdown
On BorderPE1, add the Layer-3 VRF VNI to the overlay
(config) #
interface nve 1 no shutdown source-interface loopback 1 host-reachability protocol bgp member vni 31000 associate-vrf
In the above configuration, we ensure that the Layer-3 VNI is associated with the VXLAN VTEP.
On BorderPE1, establish a multihop external BGP session to the WAN ASBR and enable forwarding of L2VPN routes towards the WAN ASBR
(config) #
router bgp 65536
neighbor 209.165.200.225 remote-as 65551
update-source loopback 100 -> Optional
ebgp-multihop 10 -> Optional
address-family vpnv4 unicast
send-community both
import l2vpn evpn reoriginate
If the BGP session to the WAN ASBR is on a directly connected interface, and the peering is done on the interface address, then the ebgp-multihop and update-source commands are not required. Also, configure the VPNv6 address family as shown below:
address-family vpnv6 unicast
send-community both
import l2vpn evpn reoriginate
Configure the BGP EVPN neighbor within the fabric.
(config) #
router bgp 65536
neighbor 10.2.2.1 remote-as 65536
update-source loopback 0
address-family l2vpn evpn
send-community both
import vpn unicast reoriginate
On BorderPE1, create the VRF under the BGP configuration to advertise the L2VPN EVPN address family (routes) within the VRF
(config) #
router bgp 65536
vrf vni-31000
address-family ipv4 unicast
advertise l2vpn evpn
maximum-paths 2
label-allocation-mode per-vrf
exit
address-family ipv6 unicast
advertise l2vpn evpn
maximum-paths 2
label-allocation-mode per-vrf
![]() Note | Alternatively, you can enable a 0/0 default route origination in each tenant VRF (on the border leaf switch). The ToRs/leaf switches will import the default route, resulting in a VRF default route towards the border leaf switch in the ToR switch tenant VRFs. |
Creation of default route and route maps on the borderPE1 switch
Enable default route origination in each VRF, for IP4 and IPv6 address families
(config) #
vrf context vni-31000 ip route 0.0.0.0/0 null 0 254 ipv6 route 0::/0 null 0 254
The ToR switches will import this default route, resulting in a VRF default route for tenant VRF vni-31000 on the ToR switches.
Create a route-map to ensure that the default route from the WAN ASBR is preferred over a default route from other sources
(config) #
route-map PREFER-EXTERNAL-DEFAULT permit 100 set local-preference 50
Apply the route map to tenant VRF vni-31000 address families (IP4 and IPv6 unicast)
(config) #
vrf vni-31000
address-family ipv4 unicast
network 0.0.0.0/0 evpn route-map PREFER-EXTERNAL-DEFAULT
exit
address-family ipv6 unicast
network 0.0.0.0/0 evpn route-map PREFER-EXTERNAL-DEFAULT
Restrict default routes generated or learned on the BorderPE switch from being distributed to the external WAN ASBR
(config) #
ip prefix-list default-route seq 5 permit 0.0.0.0/0 le 1
ipv6 prefix-list default-route-v6 seq 5 permit 0::0/0
route-map DENY-DEFAULT-ROUTE deny 10
match ip address prefix-list default-route
exit
route-map DENY-DEFAULT-ROUTE permit 1000
exit
route-map DENY-DEFAULT-ROUTE-v6 deny 100
match ipv6 address prefix-list default-route-v6
exit
route-map DENY-DEFAULT-ROUTE-v6 permit 1000
BGP specific default route configurations
Restrict default routes generated in the fabric from being distributed to external neighbors through BGP
(config) #
router bgp 65536
neighbor 209.165.200.225 remote-as 65551
address-family vpnv4 unicast
route-map DENY-DEFAULT-ROUTE out
exit
address-family vpnv6 unicast
route-map DENY-DEFAULT-ROUTE-v6 out
After the above configuration, we ensure that default routes will not be included in the VPNv4 and VPNv6 routes sent to the WAN ASBR.
Glossary
RD—Route Distinguisher
RT—Route Target
RR—BGP route reflector. A route reflector reflects incoming routes to all other leaf switch nodes. Typically, spine switches are configured as route reflectors.
BorderPE switch—A Cisco Nexus 7000 Series switch with an F3 or M3 line card; acts as the collapsed border leaf switch and Cisco Nexus 7000 Series data center edge switch. A BorderPE switch includes the MPLS PE function. This is also referred to as a one box solution.
A two box solution comprises of two switches (A Cisco Nexus 5600 Series or 7000 Series border leaf switch + a Cisco Nexus 7000 Series data center edge switch) to route IP frames from an external network into the VXLAN BGP EVPN fabric