Installing AIP-SSM
Note
All IPS platforms allow ten concurrent CLI sessions.
This chapter describes how to install AIP-SSM. It contains the following sections:
•
Specifications
•
Memory Specifications
•
Hardware and Software Requirements
•
Indicators
•
Installation and Removal Instructions
Specifications
Table 7-1 lists the specifications for AIP-SSM:
Table 7-1 AIP-SSM Specifications
|
|
Dimensions (H x W x D) |
1.70 x 6.80 x 11.00 inches |
Weight |
Minimum: 2.50 lb Maximum: 3.00 lb1 |
Operating temperature |
+32° to +104°F (+0° to +40°C) |
Nonoperating temperature |
-40° to +167°F (-40° to +75°C) |
Humidity |
10% to 90%, noncondensing |
Memory Specifications
Table 7-2 lists the memory specifications for AIP-SSM.
Table 7-2 AIP-SSM Memory Specifications
|
|
|
ASA-SSM-AIP-10-K9 |
2.0 GHz Celeron |
1.0 GB |
ASA-SSM-AIP-20-K9 |
2.4 GHz Pentium 4 |
2.0 GB |
Hardware and Software Requirements
AIP-SSM has the following hardware and software requirements:
•
Cisco ASA 5500 series adaptive security appliance
–
ASA 5510 (ASA-SSM-AIP-10-K9)
–
ASA 5520 (ASA-SSM-AIP-10-K9 and ASA-SSM-AIP-20-K9)
–
ASA 5540 (ASA-SSM-AIP-20-K9)
•
Cisco Adaptive Security Appliance Software 7.0 or later
•
Cisco Intrusion Prevention System Software 5.0(2) or later
•
DES or 3DES-enabled
Indicators
Figure 7-1 shows the AIP-SSM indicators.
Figure 7-1 AIP-SSM Indicators
Table 7-3 describes the AIP-SSM indicators.
Table 7-3 AIP-SSM Indicators
|
|
|
|
|
|
PWR |
Green |
On |
The system has power. |
|
STATUS |
Green |
Flashing |
The system is booting. |
Solid |
The system has passed power-up diagnostics. |
|
LINK/ACT |
Green |
Solid |
There is Ethernet link. |
Flashing |
There is Ethernet activity. |
|
SPEED |
Green Amber |
100 MB |
There is network activity. |
1000 MB (GigabitEthernet) |
There is network activity. |
Installation and Removal Instructions
This section describes how to install and remove AIP-SSM, and contains the following topics:
•
Installing AIP-SSM
•
Verifying the Status of AIP-SSM
•
Removing AIP-SSM
Installing AIP-SSM
To install AIP-SSM for the first time, follow these steps:
Step 1
Power off the adaptive security appliance.
Step 2
Locate the grounding strap from the accessory kit and fasten it to your wrist so that it contacts your bare skin. Attach the other end to the chassis.
Step 3
Remove the two screws at the left back end of the chassis, and remove the slot cover.
Note
Store the slot cover in a safe place for future use. You must install slot covers on all empty slots. This prevents EMI, which can disrupt other equipment.
Step 4
Insert AIP-SSM through the slot opening.
Step 5
Attach the screws to secure AIP-SSM to the chassis.
Step 6
Power on the adaptive security appliance by pushing the power switch at the back of the chassis.
Step 7
Check the indicators.
If AIP-SSM is properly installed, the POWER indicator is solid green and the STATUS indicator is flashing green. You can also verify that AIP-SSM is online using the show module 1 command.
Step 8
Initialize AIP-SSM.
Step 9
Install the most recent Cisco IPS software.
Step 10
Configure AIP-SSM to receive IPS traffic.
For More Information
•
For more information about ESD, see Working in an ESD Environment.
•
For the procedure for verifying that AIP-SSM is properly installed, see Verifying the Status of AIP-SSM.
•
For the procedure for using the setup command to initialize AIP-SSM, see Initializing the Sensor.
•
For the procedure for obtaining the latest Cisco IPS software, see Obtaining Cisco IPS Software.
•
For the procedure for configuring AIP-SSM to receive IPS traffic, refer to Configuring AIP-SSM.
•
For the procedure for using HTTPS to log in to IDM, refer to Logging In to IDM.
Verifying the Status of AIP-SSM
You can use the show module 1 command to verify that AIP-SSM is up and running.
The following values are valid for the Status field:
•
Initializing
—AIP-SSM is being detected and the control communication is being initialized by the system.
•
Up
—AIP-SSM has completed initialization by the system.
•
Unresponsive
—The system encountered an error communicating with AIP-SSM.
•
Reloading
—AIP-SSM is reloading.
•
Shutting Down
—AIP-SSM is shutting down.
•
Down
—AIP-SSM is shut down.
•
Recover
—AIP-SSM is attempting to download a recovery image.
To verify the status of AIP-SSM, follow these steps:
Step 1
Log in to the adaptive security appliance.
Step 2
Verify the status of AIP-SSM:
Mod Card Type Model Serial No.
--- -------------------------------------------- ------------------ -----------
1 ASA 5500 Series Security Services Module-20 ASA-SSM-20 P2B000005D0
Mod MAC Address Range Hw Version Fw Version Sw Version
--- --------------------------------- ------------ ------------ ---------------
1 000b.fcf8.0144 to 000b.fcf8.0144 0.2 1.0(9)0 5.0(0.27)S129.0
If the status reads Up
, AIP-SSM has been properly installed.
Removing AIP-SSM
To remove AIP-SSM from the adaptive security appliance, follow these steps:
Step 1
Shut down AIP-SSM:
asa# hw-module module 1 shutdown
Shutdown module in slot 1? [confirm]
Step 2
Press Enter to confirm.
Step 3
Verify that AIP-SSM is shut down by checking the indicators.
Step 4
Power off the adaptive security appliance.
Step 5
Locate the grounding strap from the accessory kit and fasten it to your wrist so that it contacts your bare skin. Attach the other end to the chassis.
Step 6
Remove the two screws at the left back end of the chassis.
Step 7
Remove AIP-SSM and set it aside.
Note
If you are not replacing AIP-SSM immediately, install the blank slot cover. Slot covers must cover all empty slots. This prevents EMI from disrupting other equipment.
Step 8
If you need to replace the existing AIP-SSM, insert the new AIP-SSM through the slot opening.
Note
Do not replace AIP-SSM with a different model. The the adaptive security appliance will not recognize it.
Step 9
Attach the screws to secure AIP-SSM to the chassis.
Step 10
Power on the adaptive security appliance.
Step 11
Reset AIP-SSC-5:
hostname# hw-module module 1 reset
Reset module in slot 1? [confirm]
Step 12
Press Enter to confirm.
Step 13
Check the indicators to see if AIP-SSM is properly installed.
If AIP-SSM is properly installed, the POWER indicator is solid green and the STATUS indicator is flashing green. Or you can verify installation using the show module 1command.
For More Information
•
For more information on ESD, see Working in an ESD Environment.
•
For the procedure for verifying whether AIP-SSM is properly installed, see Verifying the Status of AIP-SSM.