Overview
sd Enabling Connectivity Between On-Premises and Cloud Sites
If you have only on-premises or only cloud sites, you can skip this section.
This section describes how to enable connectivity between on-premises APIC sites and Cloud Network Controller sites.
By default, the Cisco Cloud Network Controller will deploy a pair of redundant Cisco Cloud Services Router 1000vs. The procedures in this section creates two tunnels, one IPsec tunnel from the on-premises IPsec device to each of these Cisco Cloud Services Router 1000vs. If you have multiple on-premises IPsec devices, you will need to configure the same tunnels to the CSRs on each of the on-premises devices.
The following information provides commands for Cisco Cloud Services Router 1000v as your on-premises IPsec termination device. Use similar commands if you are using a different device or platform.
Procedure
| 1. | Gather the necessary information that you will need to enable connectivity between the CSRs deployed in the cloud site and the on-premises IPsec termination device. You can get the required configuration details using either the Deploy & Download IPN Device config files or the Download IPN Device config files only option in Nexus Dashboard Orchestrator as part of the procedures provided in Deploying Infra Configuration. |
|
| 2. | Log into the on-premises IPsec device. |
|
| 3. | Configure the tunnel for the first CSR. Details for the first CSR are available in the configuration files for the ISN devices you downloaded from the Nexus Dashboard Orchestrator, but the following fields describe the important values for your specific deployment:
The following example shows intersite connectivity configuration using the IKEv2 protocol supported starting with Nexus Dashboard Orchestrator, Release 3.3(1) and Cloud Network Controller, Release 5.2(1). If you are using IKEv1, the IPN configuration file you downloaded form NDO may look slightly differently, but the principle remains the same.
Example:
|
|
| 4. | Repeat the previous step for the 2nd and any additional CSRs that you need to configure. |
|
| 5. | Verify that the tunnels are up on your on-premises IPsec device. Use the following command to display the status. If you do not see that both tunnels are shown as up, verify the information that you entered in the steps in this section to determine where you might have an issue. Do not proceed to the next section until you see that both tunnels are shown as up.
|