The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
This chapter provides various methods by which you can troubleshoot the line card installation. The troubleshooting tips are helpful for identifying the problem and resolving it. The following sections describe how to verify and troubleshoot the line card installation:
•Troubleshooting the Installation
Note Many new line cards are designated as administratively down by default. Status LEDs are off until you configure the interfaces and use the no shutdown command.
During a typical line card boot process, the following events occur:
1. The line card maintenance bus (Mbus) module receives power and begins executing the Mbus software.
2. The line card Mbus module determines the type of card on which it resides, performs internal checks, and prepares to accept the Cisco IOS XR software from the route processor (RP).
3. The RP powers up the line card and loads the line card with the Cisco IOS XR software.
To verify that the line card is working properly, perform the following operational checks:
•During the line card boot process, observe the line card alphanumeric LEDs to ensure that the card is running the typical initialization sequence. The sequence should end with the alphanumeric status message `IOX RUN'.
•Observe the line card status LEDs to verify that the Active LED (Link LED or status LED for line cards with no Active LED) is on. If an Active LED is not on, verify that the associated interface is not shut down.
If one of these conditions is not met, refer to the "Advanced Line Card Troubleshooting" section to identify any possible problems.
After installing the line card and connecting the interface cables, verify that the line card is working properly by checking the following LEDs on the faceplate:
•Interface status LEDs show the status of each fiber-optic connector. Channelized line cards with optical interfaces can contain some or all of the following status LEDs (see Figure 1-1):
–Active—Indicates the active condition of this port
–Carrier—Indicates the status of SONET framing reception on this port
–RX PKT—Indicates that data is being received on this port
Line cards with T3 ports contain a single status LED:
•Alphanumeric LEDs. Two four-digit alphanumeric LEDs display messages that explain the state of the line card. (See the "Alphanumeric LEDs" section on page 1-6.)
The status LEDs might not be on until you have configured the line card interfaces (or turned them on, if they were shut down). To verify correct operation of each interface, complete the configuration procedures for the line card. (See the "Configuring and Troubleshooting Line Card Interfaces" section.)
Note Many new line cards are designated as administratively down by default. Status LEDs are off until you configure the interfaces and use the no shutdown command.
If the Active LED (Link LED or status LED for line cards with no Active LED) or the alphanumeric display LEDs on a line card do not come on, there is either a problem with the line card installation or a hardware failure. To verify that the line card is installed correctly, follow these steps:
Step 1 If the Active LED fails to come on, but the alphanumeric display LEDs on the line card indicate activity, verify that the initialization sequence ends with IOX RUN. If this is the case, verify that the interface is not shut down. If it is not, suspect a circuitry problem with the Active LED and contact a Cisco Technical Support for further assistance.
Step 2 If the Active LED on the line card fails to come on or the alphanumeric display LEDs do not indicate IOX RUN, check the router connections as follows:
a. Verify that the line card board connector is fully seated in the backplane. Loosen the captive installation screws and firmly pivot the ejector levers toward each other until both are perpendicular to the line card faceplate. Tighten the captive installation screws.
b. Verify that all power cords and data cables are firmly connected at both ends.
c. Verify that all memory modules on the card are fully seated and secured to their sockets.
After the line card reinitializes, the Active LED on the line card should come on. If the Active LED comes on, the installation is complete; if the Active LED does not come on, proceed to the next step.
Step 3 If the Active LED still fails to come on, remove the channelized line card and try installing it in another available line card slot.
•If the Active LED comes on when the line card is installed in the new slot, suspect a failed backplane port in the original line card slot.
•If the Active LED and alphanumeric display LEDs still do not come on, halt the installation. Contact a Cisco Technical Support to report the faulty equipment and obtain further instructions.
Step 4 If an error message displays on the console terminal during the line card initialization, see the appropriate reference publication for error message definitions. If you experience other problems that you cannot solve, contact Cisco Technical Support for assistance.
This section provides an overview of SONET clocking issues. This line card supports both line and internal clocking functions. Line clocking is derived from the incoming signal from a given port. Internal clocking is derived from the clock that is internal to the line card.
Each port can be configured independently of the other in a line-timed setup, going back as far as the first payload processor. However, on the 1-Port Channelized OC-48 line card the second level of payload processing ties the ports to a common clock source that is timed from only one port. This can result in pointer justifications if the remaining ports are not synchronous. However, with a properly configured router, these pointer justifications can be limited to provide the same performance as a SONET cross-connect device.
Note Pointer justifications do not affect data throughput. All configurations of the 1-Port Channelized OC-48 line card provides total data throughput regardless of pointer justifications. Under no circumstances does any data loss occur. All configurations provide 100 percent error-free data flow.
These line cards use Stratum3 (S3) as the internal clock reference. However, if one of the ports is Stratum1 (S1) accurate, it can be used as the local reference for the system clock. In this case, pointer justifications are very limited. If the system clock is timed from an S1 clock source, from a valid SONET network, then there are no pointer justifications on any synchronous interface. There are minimal pointer justifications (limited to S1 pointer justifications) on any asynchronous interface if it is on another SONET network. Pointer justification in this case is proportional to the accuracy of the other port clock.
Note When using the show controller sonet rack/slot/module/port command, Positive Stuff Event (PSE) and Negative Stuff Event (NSE) values can be safely ignored.
The 1-Port Channelized OC-48 line card can select an input port as the source of synchronization for the system clock. This eliminates pointer justifications on any port that is synchronous with the selected port.
This section provides procedures for configuring and troubleshooting the channelized line cards:
•Configuring the 1-Port Channelized OC-48/STM-16 ISE Line Cards
•Advanced Line Card Troubleshooting
The following example describes how to perform a basic controller configuration. Use the configure command to configure the controller.
Use the following procedure to configure the 1-Port Channelized OC-48 line card. Press Enter after each configuration step unless otherwise noted.
The SONET controller name is #controller sonet 0/2/0/0 if Rack, Slot, CPU instance (0 for LCs) and Port are 0, 2, 0, 0, respectively. A Cisco XR 12000 series router, identifies an interface address by rack/slot/CPU instance/port number. By default, the 1-Port Channelized OC-48 line card is in 48xSTS-1 mode. Table 4-1 shows the configuration on the first 12 STSs.
By default, the controller is in SONET mode.
Table 4-1
|
|
|
|
|
|
|
|
|
|
|
|
|
---|---|---|---|---|---|---|---|---|---|---|---|---|
mode |
STS-3c POS |
DS3 serial |
DS3 serial |
DS3 serial |
DS3 serial |
STS-3c POS |
Controller Configuration Example
This example creates three POS interfaces named 0/2/0/0/1 on rack, slot, CPU instance and port 0,2,0,0:
0/2/0/0:router(config)# configuration
0/2/0/0:router(config)# controller sonet 0/2/0/0
0/2/0/0:router (config-controller)# sts-1 1 width 3
0/2/0/0:router (config-controller-sts1)# mode pos
0/2/0/0:router (config-controller-sts1)# commit
This example creates T3 controller named 0/2/0/0/4 on rack, slot, CPU instance, and port 0,2,0,0:
0/2/0/0:router (config)# controller sonet 0/2/0/0
0/2/0/0:router (config-controller)# sts-1 4
0/2/0/0:router (config-controller-sts1)# mode t3
0/2/0/0:router (config-controller-sts1)# commit
This example configures the framing for T3 controller on 0/2/0/0/4. STS-5, STS-6, and STS-7 shall be configured similar to STS-4:
0/2/0/0:router (config-controller-sts1)# controller t3 0/2/0/0/4
0/2/0/0:router (config-t3e3)# framing (c-bit | m23)
0/2/0/0:router (config-t3e3)# commit
This example creates POS on STS-48c:
0/2/0/0:router(config)# controller sonet 0/2/0/0
0/2/0/0:router (config-controller)# sts-1 1 width 48
0/2/0/0:router (config-controller-sts1)# mode pos
0/2/0/0:router (config-controller-sts1)# commit
The default controller configuration parameters for the 1-Port Channelized OC-48 line card are listed in Table 4-2.
|
|
|
---|---|---|
Framing |
[no] framing [sonet] |
sonet |
Clock Source |
[no] clock source [internal | line] |
line |
Loopback |
[no] loopback [internal | line] |
no loopback |
SONET overhead |
[no] overhead [j0 value] [s1s0 value] |
j0 set to 1; s1s0 set to 0x00 |
Thresholds |
[no] ber-threshold b1-tca [3..9] [no] ber-threshold b2-tca [3..9] [no] ber-threshold sd-ber [3..9] [no] ber-threshold sf-ber [3..9] |
6(10e-6) 6(10e-6) 6(10e-6) 3(10e-6) |
Alarm Reporting |
[no] alarm-report [b1-tca | b2-tca | lais | lrdi | sd-ber | sf-ber | slof | slos] |
b1-tca, b2-tca, sf-ber, slos, slof |
Shutdown |
[no] shutdown |
no shutdown |
1 Scrambling is always enabled and is not configurable. |
This section provides advanced troubleshooting information in case of a line card failure. It also provides pointers for identifying whether or not the failure is hardware related. This section does not include any software-related failures, except for those that are often mistaken for hardware failures.
Note This section assumes that you possess basic proficiency in using Cisco IOS XR software commands.
The first step is to identify the cause of the line card failure or console errors. To discover which card may be at fault, it is essential to collect the output from the following commands:
•show logging
•show diag
Along with these show commands, you should also gather the logs and additional data for troubleshooting line card installation:
•Console Logs and Syslog Information—This information is crucial if multiple symptoms are occurring. If the router is configured to send logs to a Syslog server, you may see some information on what has occurred. For console logs, it is best to be directly connected to the router on the console port with logging enabled.
•Additional Data—The show tech-support command is a compilation of many different commands, including show version, show running-config, and show stacks. This information is required when working on issues with Cisco Technical Support personnel.
Note It is important to collect the show tech-support data before doing a reload or power cycle. Failure to do so can cause all information about the problem to be lost.
Note Output from these commands varies slightly, depending on which line card you are using, but the basic information is the same.
The following are examples of system output that you may see if your Cisco XR 12000 series router line card fails:
The following command provides status details, information, and location of all nodes installed on the router:
RP/0/9/CPU0:UUT# show platform
Node Type PLIM State Config State
-----------------------------------------------------------------------------
0/6/CPU0 L3LC Eng 3 OC48-CH IOS XR RUN PWR,NSHUT,MON
0/9/CPU0 PRP(Active) N/A IOS XR RUN PWR,NSHUT,MON
The following command provides the contents of logging buffers:
RP/0/9/CPU0:UUT# show logging
Syslog logging: enabled (20 messages dropped, 0 flushes, 0 overruns)
Console logging: level informational, 79 messages logged
Monitor logging: level error, 0 messages logged
Trap logging: level informational, 0 messages logged
Buffer logging: level debugging, 99 messages logged
Log Buffer (16384 bytes):
RP/0/9/CPU0:Oct 7 12:56:39.036 : mbi-hello[61]: %PLATFORM-MBI_HELLO-7-INFO_CREATE_SUCCESS : MBI-Hello: Successful creation of /dev/mbi_lwm. Attempt number 1
RP/0/9/CPU0:Oct 7 12:56:39.141 : init[65541]: %OS-INIT-7-MBI_STARTED : total time 4.936 seconds
RP/0/9/CPU0:Oct 7 12:56:39.474 : nvram[68]: %MEDIA-NVRAM-6-UPGRADING : nvram upgrade: upgrading successful
RP/0/9/CPU0:Oct 7 12:56:39.478 : nvram[68]: %MEDIA-NVRAM-6-UPGRADING : nvram upgrade: backup all files under nvram:/ if downgrade to 3.5 or under
RP/0/9/CPU0:Oct 7 12:56:39.947 : nvram[68]: %MEDIA-NVRAM-4-BADFILES : NVRAM File Corrupted (sam_db). Some of them May be Lost
RP/0/9/CPU0:Oct 7 12:56:54.441 : sysmgr[87]: %OS-SYSMGR-5-NOTICE : Card is COLD started
RP/0/9/CPU0:Oct 7 12:56:54.749 : init[65541]: %OS-INIT-7-INSTALL_READY : total time 20.546 seconds
RP/0/9/CPU0:Oct 7 12:56:55.098 : dsc[166]: Memory Sanity Check Enabled
RP/0/9/CPU0:Oct 7 12:56:55.836 : wdsysmon[377]: %OS-RSVDPMEM-3-NO_MATCHING_STRING : Failed to find any line in /etc/platform_reserved_physmem containing string: pcds
RP/0/9/CPU0:Oct 7 12:57:07.471 : sysmgr[87]: %OS-SYSMGR-7-DEBUG : node set to DSC
(remainder of output omitted)
The following command provides hardware and software details about each node on the router:
RP/0/0/CPU0:UUT# show diag
SLOT 6 (RP/LC 6): 1 port ISE OC48 channelized STS-12c/STM-4, STS-3c/STM-1 or DS3/E3 Single Mode/SR SC-SC connector
MAIN: type 71, 800-18816-10 rev F0 dev 0
HW config: 0x01 SW key: 00-00-00
PCA: 73-7397-14 rev D0 ver 7
HW version 1.0 S/N SAL11488HVH
MBUS: Embedded Agent
Test hist: 0x00 RMA#: 00-00-00 RMA hist: 0x00
DIAG: Test count: 0x00000000 Test results: 0x00000000
FRU: Linecard/Module: CHOC48/DS3-SR-SC
Route Memory: MEM-LC-512=
Packet Memory: MEM-LC1-PKT-512=
L3 Engine: 3 - ISE OC48 (2.5 Gbps)
MBUS Agent Software version 2.56 (RAM) (ROM version is 3.7)
Using CAN Bus A
ROM Monitor version 1.13
Fabric Downloader version used 7.3 (ROM version is 7.1)
Primary clock is CSC1
Board State is IOS-XR RUN
Insertion time: Sun Oct 7 12:59:25 2001 (00:27:31 ago)
DRAM size: 536870912 bytes
FrFab SDRAM size: 268435456 bytes
ToFab SDRAM size: 268435456 bytes
0 crashes since restart/fault forgive
SLOT 9 (RP/LC 9): Cisco 12000 Series Performance Route Processor 2
MAIN: type 96, 800-27058-01 rev :6 dev 0
HW config: 0x10 SW key: 00-00-00
PCA: 73-10242-04 rev 75 ver 4
HW version 0.0 S/N SAD1023065X
MBUS: Embedded Agent
Test hist: 0x00 RMA#: 00-00-00 RMA hist: 0x00
DIAG: Test count: 0x00000000 Test results: 0x00000000
FRU: Linecard/Module: PRP-2
Route Memory: MEM-PRP/LC-1024=
MBUS Agent Software version 2.56 (RAM) (ROM version is 3.7)
Using CAN Bus A
ROM Monitor version 1.17dev(0.5)
Primary clock is CSC1
Board State is IOS-XR RUN
Insertion time: Sun Oct 7 12:57:46 2001 (00:29:11 ago)
DRAM size: 1073741824 bytes
The following command provides context information about all recent crashes:
RP/0/0/CPU0:UUT# show context
node: node0_6_CPU0
------------------------------------------------------------------
node: node0_9_CPU0
------------------------------------------------------------------
Once you have determined if the problems are caused by system errors in the log or by an actual crash, it is important to check the current status of the line card to see if it has recovered from the failure. The status of individual line cards can be identified either by examining the alphanumeric LEDs located on the front of the line card or by issuing the show led command.
RP/0/0/CPU0:UUT# show led
LOCATION MESSAGE MODE STATUS
=====================================================
0/6/CPU0 IOX RUN DEFAULT UNLOCKED
0/9/CPU0 ACTVRP DEFAULT UNLOCKED
Note It is possible for the value of an alphanumeric LED to be reversed. For example, IOX RUN may be displayed as RUN IOX.
If the alphanumeric LEDs on the line card display anything other than IOX RUN, or the RP is neither the active route processor nor the secondary route processor, there is a problem and the line card has not fully loaded correctly. Before replacing the line card, try fixing the problem by following these steps:
Step 1 Reload the line card using the global configuration hw-module location 0/0/CPU0 reload command. To reset some critical processes without affecting traffic execute the hw-module location 0/0/CPU0 reload warm command.
Step 2 Reload the line card using the hw-module slot reload command. This causes the line card to reset and download the Mbus and fabric downloader software modules before attempting to download the
Cisco IOS XR software.
or
Step 3 Reset the line card manually. This may rule out any problems that are caused by a bad connection to the Mbus or switching fabric.
Fabric ping failures occur when either a line card or the secondary RP fails to respond to a fabric ping request from the primary RP over the switch fabric. Such failures are symptoms that should be investigated. They are indicated by the following error messages:
%GRP-3-FABRIC_UNI: Unicast send timed out (1)
%GRP-3-COREDUMP: Core dump incident on slot 1, error: Fabric ping failure
%LCINFO-3-CRASH: Line card in slot 1 crashed
You can find more information about this issue on Cisco.com in the Troubleshooting Fabric Ping Timeouts and Failures on the Cisco 12000 Series Internet Router publication.
If you receive any error message related to a line card, you can use the Error Message Decoder Tool (on Cisco.com) to find the meaning of this error message. Some errors point to a hardware issue, while others indicate a Cisco IOS XR software caveat or a hardware issue on another part of the router. This publication does not cover all these messages.
Note Some messages related to Cisco Express Forwarding (CEF) and Inter Process-Communication (IPC) are explained on Cisco.com in the Troubleshooting CEF-Related Error Messages publication.
This section assumes that you are familiar with SONET/SDH alarm and signal events for SONET line cards and DS3/E3 alarms and line states for DS3/E3 line cards. Your line card does not have an LED for alarm and event detection, but you can enter the show controllers EXEC command to verify whether the alarm and event detection messages are active or inactive. Most alarm and event detection messages are short-lived, because if problems occur, the line card clears the error condition, but records the event to verify line card operation status.
To display SONET alarms, use the show controllers sonet command; to display DS3 or E3 alarms, use the show controllers serial command.
The output from the show controllers serial rack/slot/instance/port command in EXEC mode sends messages about the following types of alarms and events:
•AIS (Alarm Indication Signal)
•LOF (Loss of Frame)
•LOS (Loss of Signal)
•OOF (Out of Frame)
•RAI (Remote Alarm Indication)
The output also indicates whether the alarm or event originates from the local end connector or the remote end connector.
Some of the alarm and signal events for the SONET line cards are enabled for reporting by default. Others can be enabled individually. What the show controllers sonet command in EXEC (or administration EXEC) mode displays depends on the configuration of the SONET port.
The following partial output example from the show controllers sonet command in EXEC (or administration EXEC) mode shows alarm and event information for the second SONET controller in rack 0, slot 3, instance 0, and port 1 of a Cisco XR 12000 series router (4-Port Channelized OC-12/STM-4 ISE line card):
router# show controllers sonet 0/3/0/1
SONET3/1
Current state of the controller is up
Framing is SONET
Clock source is INTERNAL, Loopback is NONE
SECTION
LOF = 0 LOS = 0 BIP(B1) = 0
LINE
AIS = 0 RDI = 0 FEBE = 147 BIP(B2) = 0
Active Defects:None
Active Alarms: None
Alarm reporting enabled for:SF SLOS SLOF B1-TCA B2-TCA B3-TCA
APS
COAPS = 0 PSBF = 0
State:PSBF_state = False
ais_shut = FALSE
Rx(K1/K2):00/00
BER thresholds: SF = 10e-3 SD = 10e-6
TCA thresholds: B1 = 10e-6 B2 = 10e-6
Optical Power Monitoring
Laser Bias = 33.6 mA
Receiver Power = -5.80 dBm (+/- 2 dBm)
The channelized line cards include the following types of memory:
•Route memory
•Packet memory
•Pointer look-up (PLU) memory (not user serviceable)
•Table look-up (TLU) memory (not user serviceable)
Line card memory configurations and memory socket locations differ, depending on the line card engine type. Table 4-3 lists the channelized and electrical interface line card engine types.
|
|
---|---|
1-Port Channelized OC-48/STM-16 ISE |
Internet Services Engine (ISE) |
The following sections contain general line card memory information for each channelized and electrical interface line card:
•ISE Line Card Memory Locations
Memory removal and installation instructions are found in the "Removing and Installing Line Card Memory" section.
Figure 4-1 shows the small outline DIMM (SODIMM) socket locations on an ISE line card. This line card is equipped with 10 SODIMM sockets:
•Two route memory SODIMM sockets
•Four packet memory sockets (not user serviceable)
•Four TLU/PLU memory sockets (not user serviceable)
Figure 4-1 ISE Line Card Memory Locations
|
Route memory SODIMM0 |
|
Four packet memory SODIMM sockets (not field serviceable) |
|
Route memory SODIMM1 |
|
Four TLU/PLU memory SODIMM sockets (not field serviceable) |
There are two route memory sockets on ISE (Engine 3) line cards that support the addition of route memory modules. Table 4-4 describes the various memory upgrade options.
|
|
|
---|---|---|
1-Port Channelized OC-48/STM-16 |
• • • |
• • • • |
1 If you need to upgrade beyond 2 x 512 MB modules, you must contact the Cisco Technical Support Personnel for instructions. 2 Do not mix memory sizes. Both DIMMs must be the same size memory. 3 Requires Cisco IOS XR Release 3.2 or a later release, and you must upgrade the route processor ROMMON code to Version 1.13 or later before installing the upgraded memory. |
Table 4-5 lists the available route memory options for 1-Port Channelized OC-48 line card. The 1-Port Channelized OC-48 line card is available with 512-MB route memory (MEM-LC-ISE-512) at no cost today.
|
|
|
|
1 GB |
MEM-LC-ISE-1G1 |
2 512-MB SODIMM |
DIMM0 and DIMM1 |
1 This order number is used whether you are replacing or upgrading the route memory. The default memory on ISE line cards is 512 MB. This is provided either as two 256-MB SODIMMs or as one 512-MB SODIMM. |
Before beginning the memory replacement procedures in this section, ensure that you have the proper tools and equipment at hand, and that you are using appropriate ESD-prevention equipment and techniques. This section contains the following procedures:
•Checking the Installation of Line Card Memory
Refer to Figure 4-1 for the location of the memory on your line card.
To remove a SODIMM, follow these steps:
Step 1 Attach an ESD-preventive wrist or ankle strap and follow its instructions for use.
Step 2 Place the line card on an antistatic mat so that the faceplate is nearest to you.
Step 3 Locate the route memory socket on the line card.
Step 4 If present, remove the SODIMM retaining clip from the memory module socket. Grasp the latch arm intersection located on each side of the clip and gently slide the clip out. (See Figure 4-2.) Save the retaining clip.
Note Some line cards do not require a retaining clip.
Figure 4-2 Remove Retaining Clip from Memory Module Socket
Step 5 Remove the SODIMM by gently moving the plastic latches in an outward direction, parallel to and away from the memory module, until it releases and rotates to a 45-degree angle. (See Figure 4-3 and Figure 4-4a.)
Figure 4-3 Moving the Plastic Latch Away from the SODIMM
Step 6 As the SODIMM is released, it positions itself at a 45-degree angle. Gently pull the SODIMM module out of the socket. Continue to keep the module at a 45-degree angle until it is completely removed from the socket guides. (See Figure 4-4b.)
Figure 4-4 Removing a 144-pin SODIMM Module
Step 7 Immediately place the SODIMM in an antistatic bag to protect it from ESD damage.
To install a SODIMM module, follow these steps:
Step 1 Attach an ESD-preventive wrist or ankle strap and follow its instructions for use.
Step 2 Place the line card on an antistatic mat so that the faceplate is nearest to you.
Step 3 If there is a retaining clip, check to make sure that it has not been damaged or bent. (See Figure 4-5.)
Note Some line cards do not require a retaining clip.
Figure 4-5 SODIMM Socket Retaining Clip
Step 4 Locate the route memory socket on the line card.
Step 5 Remove the new SODIMM from its protective antistatic bag.
Step 6 Line up the SODIMM key with the key in the board socket. (See Figure 4-6.)
Figure 4-6 SODIMM with Key in Face-up Position
Step 7 The SODIMM must be lined up at a 45-degree angle. (See Figure 4-7a.)
Note When the key is in the face-up position, the metal traces on the left side of the key measure 0.9 inch (23.20 mm). The metal traces on the right side of the key measure 1.29 inches (32.80 mm). The SODIMM can not be inserted until the keys are lined up properly.
Step 8 Place both thumbs at the end of the socket and use your index fingers to guide the module into the socket until it is fully seated.
Be sure that your index fingers are located on the outer corners of the SODIMM to maintain even pressure when the module is being seated in the socket.
Figure 4-7 Inserting a 144-pin SODIMM Module
Step 9 Gently press the SODIMM down using your index fingers, distributing even pressure across the module until it locks into the tabs. (See Figure 4-7b.)
Step 10 Verify that the release levers are flush against the side of the socket. If they are not, the SODIMM might not be seated properly.
Step 11 If the module appears misaligned, carefully remove it and reseat it, ensuring that the release lever is flush against the side of the SODIMM socket.
Step 12 If there is a retaining clip, insert it by sliding the clip between the metal strain relief and the plastic latch.
(See Figure 4-8.)
Figure 4-8 Inserting the Retaining Clip
The clip is properly installed when the clip detente protrudes below the strain relief and plastic latch. (See Figure 4-9.)
Figure 4-9 Retaining Clip Completely Installed into Module Latch
After you install line card memory and reinstall the line card in the router, the router reinitializes the line card and detects the memory change as part of the reinitialization cycle. The time required for the router to initialize can vary with different router configurations and memory configurations. A router with larger SODIMMs, for example, might take longer to boot.
If the line card does not reinitialize properly after you upgrade the SODIMMs on the line card, or if the console terminal displays a checksum or memory error, verify that you installed the correct SODIMM module and that it is installed correctly on the line card.
To check the installation of line card memory, follow these steps:
Step 1 Remove the line card from the card cage as described in the "Removing a Line Card" section on page 3-3.
Step 2 Check the alignment of the SODIMM looking at it across the horizontal plane of the card. The SODIMM module should be aligned at the same angle as shown in Figure 4-7 and be fully inserted into its socket.
If a SODIMM is not correctly aligned, remove it and reinsert it.
Step 3 Reinstall the line card in the card cage as described earlier in this publication and perform another installation check.
If the card fails to restart properly after several attempts and you are unable to resolve the problem, access Cisco.com or contact your Cisco Technical Support representative for assistance. Before calling, make note of any console error messages, unusual LED states, or other router indications or behaviors that might help to resolve the problem.
The following section provides details of 1-Port Channelized OC-48 line card physical layer features:
•Supported and Unsupported Channelization Modes
Line cards are available in following types:
•1-Port Channelized OC-48 line card
•4-Port Channelized OC-12/STM-4 ISE
•16-Port Channelized OC3 Line Card
Only the 1-Port Channelized OC-48 line card is supported on the Cisco XR 12000 series router running on Cisco IOS XR software.
Note The 1-Port Channelized OC-48 line card must have Gulf application specific integrated circuit (ASIC) version greater than or equal (>=) to 4 on Cisco IOS XR software. Gulf ASIC version less than (<) 4 would be rejected on Cisco IOS XR software. Please enable dynamic provisioning when using Gulf version >= 4 on Cisco IOS software. Enabling of dynamic provisioning is applicable only for Cisco IOS software. Cisco IOS XR software always keeps dynamic provisioning enabled.
The 1-Port Channelized OC-48 line card supports only the SONET mode of operation. The line card does not support SDH framing in the current release of Cisco IOS XR software. The following section describes:
•Supported Channelization Modes
•Unsupported Channelization Modes
•SONET Path Concatenation Restrictions
The 1-Port Channelized OC-48 line card supports the following channelization modes in the current release of Cisco IOS XR software:
•STS-48c
•STS-12c
•STS-3c
•STS-1
•STS-1, DS3
•All valid combinations of these modes are supported.
The 1-Port Channelized OC-48 line card does not support the following channelization modes in the current release of Cisco IOS XR software:
•STS-1 > E3
•E3 > E1
•T3 > T1
•STS-1 > VT2 > E1
•AU-4 > TUG-3 > VC-3 > DS3 > T1/E1
•AU-4 > TUG-3 > TUG-2 > VC11 > T1
•AU-3 > VC-3 > E3
•AU-3 > TUG-2 > VC12> E1
The SDH unsupported modes for Release 3.7 are:
•AU-4-16c (VC-4-16c)
•AU-4-16c (VC-4-4c)
•AU-4 (VC-4)
•AU-4 > TUG-3> VC-3> DS3
•AU-4 > TUG-3 > VC-3 > E3
•AU-3 > VC-3 > DS3
Concatenation of Synchronous Transport Signal (STS) paths is supported only at GR-253 specified boundaries along with the restriction that nonstandard widths are not supported. Only contiguous STS paths can be concatenated. This limits the concatenation support to following STS paths, with numbers in bracket identifying the first STS number for a given STS path:
•STS-1 (1, 2, 3, ...)
• STS-3c (1, 4, 7, 10, ...)
• STS-12c (1, 13, 25, 37)
• STS- 48c (1)
The following types of loopback are supported at the SONET line level:
•Local Line Loopback
•Network Line Loopback
SONET paths cannot be individually configured for loopback.
The following encapsulation methods are supported by 1-Port Channelized OC-48 line card on POS and serial interfaces:
•High-level Data Link Control (HDLC)
•Point to Point Protocol (PPP)
•Frame Relay
This feature provides 1+1 single-router automatic protection switching (SR-APS) for the 1-Port Channelized OC-48 line card (Engine 3) in the Cisco XR 12000 series router. By installing two identical line cards in physically adjacent slots and bridging traffic across both line cards, the Cisco XR 12000 series router SR-APS implementation provides SONET line and line card redundancy within a single router. This feature supports high availability and is intended for routers deployed at the service provider multiservice edge.
The 1-Port Channelized OC-48 line card supports C-bit Parity and M-23 mode of framing for DS3 paths with C-bit as the default. The 1-Port Channelized OC-48 line card does not support unframed operation for DS3 paths. Automatic configuration of transmit framing mode based on the detection of received framing mode is not supported. DS-3 C-bit parity format was advanced to increase far-end performance monitoring. In this format, because stuff bits are used at every opportunity, C-bits can be used for purposes other than denoting the presence of stuff bits, including:
•Far End Alarm and Control (FEAC) signal. In this case, C-bits are used to send alarm or status information from far-end terminals to near-end terminals and to initiate DS-3 and DS-1 remote loops. This is a repeating 16-bit word consisting of 0xxxxxx0 11111111. When no code is being transmitted, all 1's are transmitted. The code is transmitted for 10 times or the alarm state length, whichever is longer.
•DS-3 path parity information.
•Far-end block errors.
•Terminal-to-terminal path maintenance data link (LAPD, subset of Q.921).
FEAC is a communication channel between the far-end DS-3 terminal equipment and the near-end-DS-3 terminal equipment to send alarm and status information and loopback commands. FEAC is supported on the 1-Port Channelized OC-48 line card in DS-3 C-bit mode.
BERT (Bit-Error Rate Testing) tests are used for analyzing quality and for problem resolution of digital transmission equipment. BERT tests the quality of an interface by directly comparing a pseudo-random or repetitive test pattern with an identical locally generated test pattern. BERT tests can be run on T3/E3 interfaces.
The BERT operation is data-intrusive. Regular data cannot flow on the T3/E3 path while the test is in progress. The path is reported to be in alarm state when BERT is in progress and restored to a normal state after BERT has been terminated.
The supported DS-3 BERT patterns on the line card are as follows:
• Pattern 2^15-1 (O.150)
• Pattern 2^20-1 (O.151)
• Pattern unframed-2^15
• Pattern unframed-2^20
It is also possible to insert single errors into the patterns.
The 1-Port Channelized OC-48 line card supports different loopbacks at DS-3/E3 level.
DS-3 supports following loopbacks:
•Network Loopback
•Remote Loopback (This is done using FEAC in C-Bit mode for T3.)
E3 supports following loopbacks:
•Local Loopback
•Network Loopback
Note Far-end equipment cannot command (using FEAC) the DS-3 path terminated on the 1-Port Channelized OC-48 line card to go into the loopback state.
This section includes regulatory, compliance, and safety information.
The complete list of translated safety warnings and agency approvals is available in the Regulatory Compliance and Safety Information for Cisco 12000 Series Internet Routers publication.
(Document Number 78-4347-xx.)
This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio-frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference, in which case users will be required to correct the interference at their own expense.
Modifying the equipment without Cisco's authorization may result in the equipment no longer complying with FCC requirements for Class A digital devices. In that event, your right to use the equipment may be limited by FCC regulation and you may be required to correct any interference to radio or television communication at your own expense.
You can determine whether your equipment is causing interference by turning it off. If the interference stops, it was probably caused by the Cisco equipment or one of its peripheral devices. If the equipment causes interference to radio or television reception, try to correct the interference by using one or more of the following measures:
•Turn the television or radio antenna until the interference stops.
•Move the equipment to one side or the other of the television or radio.
•Move the equipment farther away from the television or radio.
•Plug the equipment into an outlet that is on a different circuit from the television or radio. (That is, make certain the equipment and the television or radio are on circuits controlled by different circuit breakers or fuses.)
This apparatus complies with CISPR 22/EN55022 Class B radiated and conducted emissions requirements.
This class A digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe A est conforme à la norme NMB-003 du Canada.
This apparatus complies with EN55022 Class B and EN55024 standards when used as ITE/TTE equipment, and EN300386 for Telecommunications Network Equipment (TNE) in both installation environments, telecommunication centers and other indoor locations.
Channelized line cards are equipped with a Class 1 laser, which emits invisible radiation. Do not stare into operational line card ports. The following laser warnings apply to the channelized and electrical interface line card:
•Class 1 Laser Product Warning
The following warning applies to single-mode SR, IR, and LR optics:
Warning Class 1 laser product.
The following warning applies to the channelized and electrical interface line card:
Warning Invisible laser radiation can be emitted from the aperture of the port when no cable is connected. Avoid exposure to laser radiation and do not stare into open apertures.
For translated safety warnings, refer to the Regulatory Compliance and Safety Information for
Cisco 12000 Series Internet Routers publication (Document Number 78-4347-xx).