The documentation set for this product strives to use bias-free language. For the purposes of this documentation set, bias-free is defined as language that does not imply discrimination based on age, disability, gender, racial identity, ethnic identity, sexual orientation, socioeconomic status, and intersectionality. Exceptions may be present in the documentation due to language that is hardcoded in the user interfaces of the product software, language used based on RFP documentation, or language that is used by a referenced third-party product. Learn more about how Cisco is using Inclusive Language.
This appendix includes the following sections:
•Compliance and Safety Information
The router specifications are presented in the following four tables:
•Table A-1, "Physical Specifications for Cisco 12000 Series Routers"
•Table A-2, "AC Electrical Specifications"
•Table A-3, "DC Electrical Specifications"
•Table A-4, "Environmental Specifications"
|
|
---|---|
Power • • |
4800 W maximum (for 3 AC-input power supplies—N+1 redundancy) 4800 W maximum (for 4 AC-input power supplies—N+2 redundancy) |
Rated input voltage1 |
200 to 240 VAC nominal (range: 180 to 264 VAC) |
Rated input line frequency1 |
50 to 60 Hz nominal (range: 47 to 63 Hz) |
Input current rating1 |
13 A maximum @ 200 to 240 VRMS |
Source AC service requirement1 |
20 A North America; 16 A international |
1 For each power supply module (three in the standard shelf; four in the optional shelf). |
|
|
---|---|
Power |
4800 W maximum |
Rated input voltage1 |
-48 VDC nominal in North America |
Input current rating |
60A maximum @ 40.5 VDC |
Source DC service requirement |
Sufficient to supply the rated input current. Local codes apply. |
1 For each PEM. ![]() ![]() |
|
|
---|---|
Temperature |
Operating: 32° to 104°F (0° to 40°C) Nonoperating: -4° to 149°F (-20° to 65°C) |
Humidity |
Operating: 10 to 90% noncondensing Nonoperating: 5 to 95% noncondensing |
Altitude |
Operating: 0 to 10,000 ft (0 to 3,000 m) Nonoperating: 0 to 15,000 ft (0 to 4,570 m) |
Heat dissipation |
16,378 BTU/hr maximum |
Acoustic noise |
70 dBa maximum |
Shock |
Operating (halfsine): 21 in./sec (0.53 m/sec) Nonoperating (trapezoidal pulse): 20G1 , 52 in./sec (1.32 m/sec) |
Vibration |
Operating: 0.35 Grms2 from 3 to 500 Hz Nonoperating: 1.0 Grms from 3 to 500 Hz |
1 G is a value of acceleration, where 1G equals 32.17 ft/sec2 (9.81 m/sec2). 2 Grms is the root mean square value of acceleration. |
The Cisco 12016, Cisco 2416 and Cisco 12816 routers are designed to meet the regulatory compliance and safety approval requirements. Refer to the Regulatory Compliance and Safety Information for the Cisco 12000 Series Router (Document Number 78-4347-xx) if you require additional compliance information (see the "Obtaining Documentation and Submitting a Service Request" section on page -xiv for site information).