Card Protection for 48-Port T1/E1 CEM and 48-Port T3/E3 CEM Interface Modules

The Card Protection feature is introduced for the 48-Port T1/E1 and 48-port T3/E3 interface modules. In this feature, the interface module bay is protected by another interface module of the same type.

The Card Protection feature is required to protect traffic flow either when an interface module is out of service, when the software fails or a hardware component has issues. Because card protection is supported only on redundant interface modules, traffic is switched to the protect interface module when the active interface module does not respond, and vice-versa.


Note

This feature does not require any change in the patch panel of the interface modules.


In card protection, a Y Cable is used to multiplex the signal from the patch panel to both the ports of active and protect interface modules. Both ports receive the signal, but only the active interface module transmits the signal from its port.
Figure 1. Y Cable

To support the Card Protection feature, the configuration on the active and protect interface module must be same. To achieve this, a virtual interface module is created with the same interface module type as the active interface module. A virtual controller is also created, which broadcasts the configuration to both the interface modules. The configuration on the physical controllers is then blocked and you can make configuration changes only on the virtual controller. The user configuration can only be performed on the virtual controller.

The virtual controller supports CEM level configuration and all other configurations. These configurations are blocked on physical controllers.

Figure 2. Card Protection Topology

Note

DS3 (T3) channelized into T1 and E3 channelized into E1s are supported in card protection. For more information on configuration, see the Configuring the Controller of Channelized T3/T1 Interfaces section.


Y Cable

In card protection, a Y cable is used to multiplex the signal from the patch panel to both the ports of active and standby interface modules. Both the active and protect ports receive the signal, but only the active port transmits the signal from its port. Protect port transmitter is disabled.

Card Protection Switchover

The following table shows the card protection switchover trigger and time to complete the switchover between the working and protect interface module.

Trigger

Time

Interface Module Reload with CLI OIR

Less than 50 millisecond

Non-responsive Interface Module Process (interface module reloads on its own, the reload is initiated due to software error)

100 millisecond to 200 millisecond

Interface Module shuts down due to high temperature

Less than 50 millisecond

Interface Module shuts down using CLI

Less than 50 millisecond

Interface Module stops using CLI

Less than 50 millisecond

Card Physical Jackout

100 millisecond to 200 millisecond

Serializer/Deserializer (SerDes) Failures

250 millisecond to 1 second

Alarm Based Switchover

Based on Hold Over Time or Soak Time

Card Protection Commands

20 millisecond to 30 millisecond

Non-responsive Interface Module Process (interface module reloads on its own, the reload is initiated due to software error)

200 millisecond to 1 second

Card Physical Jackout

200 millisecond to 1 second

Alarm Based Switchover

Alarm based switchover is only applicable for Loss Of Signal (LOS) alarm. Switchover happens only when the number of ports with LOS alarm in working interface module is greater than that on the protect interface module.

Each card protection group maintains a weight for each working and protect interface module. This weight is updated when the LOS alarms are asserted or cleared. The switchover happens only if the weight of working interface module and protect interface module stays same for a certain amount of time called soak time.

When there is any issue with the Patch Panel, both working interface module and protect interface module have the same number of LOS alarms (weights are same). Hence, switchover does not happen.

Restrictions

  • Card physical jack out convergence time for card protection switchover is more than 50 milliseconds.

  • The time taken to restart the interface module due to any software error is more than 50 milliseconds.

  • Alarm toggle on active or backup card causes at least one card protection switch.

  • When BERT is started from the virtual controllers, the syslog displays the physical controllers instead of the virtual controller port.

Supported Features on Interface Module

The supported features are:

  • Switching Mode

    • Non-revertive mode

    • Revertive mode

  • Alarm Based Switchover

  • SerDes Based Switchover

  • Adaptive Clock Recovery (ACR) on virtual CEM

  • Differential Clock Recovery (DCR) on virtual CEM

  • Maintenance Commands

    • Lockout

    • Force

    • Manual


Note

All controller configurations are performed on the virtual controller.


You can create card protection with one slot (either primary or backup) and the remaining slots can be added later.

Configuring Maintenance Commands

To configure maintenance commands:

enable
configure terminal
card-protection 4
primary slot 0 bay 0
backup slot 0 bay 5
end
card-protection 4
card-protection [manual {backup|primary} | force {backup|primary} | lockout]
end

Note

Maintenance commands are not synced in the standby environment. After Redundancy Force Switchover (SSO), maintenance commands must be executed again on the new active environment.


Priority Table

The following table shows the priority of the actions:

Priority

Configurations

1

Lockout

2

Force

3

Alarm or Card Failure

4

Manual Switch

5

Revert

Configuring T3/E3 Card Protection

Pre-requisites

The interface module should be free from any configuration.

Configuring Card Protection Group:

enable
configure terminal
card-protection [1-16]
primary slot 0 bay 0
backup slot 0 bay 5
end

Note

The card protection number 1 to 16 refers to the Card Protection Group Number (CPGN).



Note

This is a non-revertive mode.


Configuring Virtual Card and Virtual Controller:

When card protection group is configured, it creates virtual card for card protection object, denoted by 8/x/port. Slot 8 is a fixed slot number for all card protection-created virtual card. Bay number ‘x’ is derived from the CPGN, where x=CPGN-1. Since card protection group number ranges from 1 to16, bay number ranges from 0 to 15. Virtual controllers can be configured from 8/x/0 to 8/x/47.

Physical Card Configuration:

Configures mode T3/E3 on physical controllers of both primary (0/0) and backup (0/5) card.

enable
configure terminal
controller mediatype 8/0/0
mode t3
end

Virtual Card Configuration:

  • Configures mode T3/E3 on virtual controllers.

  • Configures CEM on virtual controller (8/x/port).

  • Configures xconnect and local connect on CEM interface.

enable
configure terminal
controller t3 8/0/0
cem 0 unframed
interface cem 8/0/0
cem 0
xconnect 11.1.1.1 112 encasulation mpls
end

Note

This is a non-revertive mode.



Note

To un-configure a CEM group under a virtual controller, first perform shutdown of the virtual controller and then un-configure the CEM group.


Configuring Revertive Mode

To configure revertive mode:

enable
configure terminal
card-protection 4
primary slot 0 bay 0
backup slot 0 bay 5
end
card-protection 4
revertive time [30-720]
end

Note

The revertive time ranges from 30 to 720 seconds.


Verifying T3/E3 Card Protection Configuration

Use show card-protection detail command to verify card protection group configuration.

#show card-protection 2 detail
Working(0/1:A900-IMA48T-C NCS4200-48T3E3-CE): 
    Number of LOS Alarms:7 
    ok,Active
    1:1,  Revertive 

    Protect(0/2:A900-IMA48T-C NCS4200-48T3E3-CE): 
    Number of LOS Alarms:7 
    ok,Inactive
    1:1,  Revertive 

Revert Timer : (Not Started)
Last switchover reason :None
#show card-protection 4
CPGN   Primary Card               Backup Card              Active  
-------------------------------------------------------------------------------
4      0/1                        0/2                      Primary              
#show running-configuration | b 8/0/
controller mediatype 8/0/0
!
controller mediatye 8/0/1
!
controller mediatype 8/0/2
#

Use show xconnect all command to verify xconnect configuration.

#show xconnect all
XC ST=Xconnect    State   S1=Segment1 State     S2=Segment2 State
UP=Up   DN=Down     AD=Admin Down     IA=Inactive
SB=Standby  HS=Hot Standby    RV=Recovering    NH=No Hardware
XC   ST    Segment 1                    S1 Segment 2                      S2
–––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––––
UP   pri   ac CE8/0/0:0(SATOP T3)        UP mpls 11.1.1.1:112              UP
#

Configuring T1/E1 Card Protection

Configuring Card Protection Group:

enable
configure terminal
card type t1 0 2
card type t1 0 1
card-protection [1-16]
primary slot 0 bay 1
backup slot 0 bay 2
end

Note

The card protection number 1 to 16 refers to CPGN.


Configuring Virtual Card and Virtual Controller:

When card protection group is configured, it creates virtual card for card protection object, denoted by 8/x/port. Slot 8 is a fixed slot number for all card protection created virtual card. Bay number ‘x’ for virtual card is x =CPGN -1 = 15. Virtual controllers can be configured from 8/15/0 to 8/15/47.

Physical Card Configuration:
  • No configuration is required for traffic.

Virtual Card Configuration:

  • Configures CEM on virtual controller (8/x/port).

  • Configures xconnect and local connect on CEM interface.

enable
configure terminal
controller t1 8/15/0
cem 0 unframed
interface cem 8/15/0
cem 0
xconnect 11.1.1.1 212 encasulation mpls
end
enable
configure terminal
controller t1 8/15/11
cem 0 unframed
interface cem 8/15/11
cem 0
connect testLC cem 8/15/0 0 cem 8/15/11 0
end

Note

To un-configure a CEM group under a virtual controller, first perform shutdown of the virtual controller and then un-configure the CEM group.


Configuring Revertive Mode

To configure revertive mode:

enable
configure terminal
card-protection 4
primary slot 0 bay 0
backup slot 0 bay 5
end
card-protection 4
revertive time [30-720]
end

Note

The revertive time ranges from 30 to 720 seconds.


Verification of T1/E1 Card Protection Configuration

Use show card-protection command to verify card protection group configuration.

#show card-protection 2 detail
Working(0/1:A900-IMA48T-C NCS4200-48T1E1-CE): 
    Number of LOS Alarms:7 
    ok,Active
    1:1,  Revertive 

    Protect(0/2:A900-IMA48T-C NCS4200-48T1E1-CE): 
    Number of LOS Alarms:7 
    ok,Inactive
    1:1,  Revertive 

Revert Timer : (Not Started)
Last switchover reason :None

Use show xconnect all command to verify xconnect configuration.

#show xconnect all | I CE8/15/
UP   pri   ac CE8/15/0:0(SATOP T1)        UP mpls 11.1.1.1:212              UP
#
#show xconnect all | i CE8/15/
72       testLC         CE8/15/11 SAT1 0        CE8/15/12 SAT1 0              UP
#

Associated Commands

The following table shows the commands for the IM configuration:

Command

Link

Card Protection Creation Commands:

card-protection CPGN

card-protection {primary | backup}

card-protection revertive time

Card Protection Maintenance Commands:

card-protection CPGN [manual {primary | backup} | force {primary | backup} | lockout ]

https://www.cisco.com/c/en/us/td/docs/ios-xml/ios/interface/command/ir-cr-book/ir-c1.html#wp1208639895

show card-protection CPGN detail

https://www.cisco.com/c/en/us/td/docs/ios-xml/ios/interface/command/ir-cr-book/ir-s2.html#wp1628614402

Additional References

Related Documents

Related Topic

Document Title

Cisco IOS commands

Cisco IOS Master Commands List, All Releases

Compact-SFP

Cisco SFP Modules for Gigabit Ethernet Applications Data Sheet

Standards and RFCs

Standard/RFC

Title

There are no standards and RFCs for this feature.

MIBs

MIB

MIBs Link

There are no MIBs for this feature.

http://www.cisco.com/go/mibs

Technical Assistance

Description

Link

The Cisco Support website provides extensive online resources, including documentation and tools for troubleshooting and resolving technical issues with Cisco products and technologies.

To receive security and technical information about your products, you can subscribe to various services, such as the Product Alert Tool (accessed from Field Notices), the Cisco Technical Services Newsletter, and Really Simple Syndication (RSS) Feeds.

Access to most tools on the Cisco Support website requires a Cisco.com user ID and password.

http://www.cisco.com/cisco/web/support/index.html