Installing ONS 15454 SDH FMEC-DS1/E1 Cards
FMEC-DS1/E1 Front Mount Electrical Connection Card Description
FMEC-DS1/E1 Card-Level Indicators
FMEC-DS1/E1 Card Specifications
Verify Successful Turn Up of the FMEC-DS1/E1 Card
Obtaining Documentation and Submitting a Service Request
Installing ONS 15454 SDH FMEC-DS1/E1 Cards
Product Name: 15454E-120E1-FMEC=
This document contains a description of FMEC-DS1/E1 card features, installation procedures, removal instructions, and technical specifications. Use this document in conjunction with the Cisco ONS 15454 SDH Installation and Operations Guide and the Cisco ONS 15454 SDH Troubleshooting and Reference Guide when working with FMEC-DS1/E1 cards.
This document contains the following sections:
•
"FMEC-DS1/E1 Front Mount Electrical Connection Card Description" section
•
"FMEC-DS1/E1 Card Specifications" section
•
"Installation Procedures" section
•
"Related Documentation" section
•
"Obtaining Documentation and Submitting a Service Request" section
This document contains the following procedures:
"Installation Procedures" procedure
"Verify Successful Turn Up of the FMEC-DS1/E1 Card" procedure
"Removal Procedures" procedure
![]()
Note
For information about circuits and card capacities, see the Cisco ONS 15454 SDH Installation and Operations Guide.
FMEC-DS1/E1 Front Mount Electrical Connection Card Description
The ONS 15454 SDH FMEC-DS1/E1 card (Figure 1) provides front mount electrical connection for fourteen ITU-compliant, G.703 E-1 ports. With FMEC-DS1/E1, each E1-N-14 port operates at 2.048 MBits/s (Mbps) over a 120 ohms balanced cable via two 37-pin DB connectors.
![]()
CautionThese E1 ports on the FMEC-DS1/E1 interface card are only capable to be connected to SELV circuits. The E1 interface is not intended for connection to any Australian Telecommunications networks without written consent of the network manager.
Figure 1 shows the FMEC-DS1/E1 faceplate. Figure 2 shows the block diagram.
Figure 1 FMEC-DS1/E1 faceplate
![]()
You can install the FMEC-DS1/E1 card in any EFCA (Electrical Facility Connector Assy) slot from slot 18 to 22 or slot 25 to 29 on the ONS 15454 SDH. Each FMEC-DS1/E1 card port features E1-level inputs and outputs supporting cable losses of up to 6 dB @ 1024 kHz.
Figure 2 FMEC-DS1/E1 block diagram
![]()
FMEC-DS1/E1 Card-Level Indicators
The FMEC-DS1/E1 faceplate has no card-level LEDs.
FMEC-DS1/E1 Card Specifications
•
FMEC-DS1/E1 Input
–
Bit Rate: 2.048 MBits/s (Mbps) + 50 ppm
–
Line Code: HDB-3
–
Termination: Balanced twisted pair cable
–
Input Impedance: 120 ohms + 5%
–
Cable Loss: up to 6 dB @ 1024 kHz
•
FMEC-DS1/E1 Output
–
Bit Rate: 2.048 MBits/s (Mbps) + 50 ppm
–
Line Code: HDB-3
–
Termination: Balanced twisted pair cable
–
Output Impedance: 120 ohms + 5%
–
Pulse Shape: ITU-T G.703 Figure 15 / Table 7
–
Pulse Amplitude: ITU-T G.703 Figure 15 / Table 7
•
FMEC-DS1/E1 Electrical Interface
–
Connectors: 37-pin DB connectors
•
Environmental
–
Operating Temperature: -5 to +45 degrees Celsius
–
Operating Humidity: 5 - 95%, non-condensing
–
Power Consumption: 0.00 W, 0.00 A (AMPS) @ -48V, 0.0 BTU/Hr.
•
Dimensions
–
Height: 182 mm, (7.165 in.)
–
Width: 32 mm, (1.25 in.)
–
Depth: 92 mm, (3.62 in.)
–
Depth with backplane connector: 98 mm, (3.87 in.)
–
Weight not including clam shell: 0.3 kg (0.6 lbs.)
•
Compliance
ONS 15454 SDH cards, when installed in a system, comply with these standards:
–
Safety: IEC 60950, EN 60950, UL 60950, CSA C22.2 No. 60950, TS 001, AS/NZS 3260
Installation Procedures
Use this section if you are installing or removing the FMEC-DS1/E1 card for the first time. After you become familiar with ONS 15454 SDH card installation and boot up, use this section as a reference.
![]()
CautionAlways use the supplied electrostatic discharge (ESD) wristband when working with an ONS 15454 SDH. Plug the wristband cable into the ESD jack located on the lower right outside edge of the shelf assembly and ensure the shelf assembly is properly grounded.
![]()
CautionHazardous voltage or energy may be present on the backplane when the system is operating. Use caution when servicing.
Step 1
Carefully insert the card into the rails of the desired slot (Figure 3).
Step 2
Move the upper ejector down and the lower ejector up to enable the card being inserted into the backplane connectors.
Step 3
Gently push the card into the connector on the back plane.
Step 4
Tighten the front mounting screws with a Phillips or slot screwdriver.
FMEC-DS1/E1 cards have electrical plugs that plug into electrical connectors on the shelf assembly backplane. When the ejectors are fully closed and the mounting screws are tightened, the card plugs into the shelf assembly backplane. Figure 3 shows general card installation.
Figure 3 Installing an FMEC card in an ONS 15454 SDH
![]()
Card Turn Up
Follow the steps in this section to verify card turn up. If one or more of the Cisco Transport Controller (CTC) software screen conditions according to "Verify Successful Turn Up of the FMEC-DS1/E1 Card" section are not met, re-install the card. Replace the unit if the faulty state persists.
Verify Successful Turn Up of the FMEC-DS1/E1 Card
Step 1
Verify that power is applied to the shelf assembly.
Step 2
Verify that the FMEC-DS1/E1 card has been installed in the correct slot (Slot 18 to 22 or 25 to 29, for the E1-N-14 card in slot 1 to 5 or 13 to 17, respectively).
Step 3
Verify that the card appears in the correct slot on the CTC software screen.
Step 4
Verify that the card is white on the CTC software screen.
Step 5
Verify that the card is shown in Inventory on the CTC software screen.
Removal Procedures
Use this section if you are installing or removing the FMEC-DS1/E1 card for the first time. After you become familiar with ONS 15454 SDH card installation and boot up, use this section as a reference.
![]()
CautionAlways use the supplied electrostatic discharge (ESD) wristband when working with an ONS 15454 SDH. Plug the wristband cable into the ESD jack located on the lower right outside edge of the shelf assembly and ensure the shelf assembly is properly grounded.
![]()
CautionHazardous voltage or energy may be present on the backplane when the system is operating. Use caution when servicing.
Step 1
If there is traffic on the card, route this traffic to other interfaces.
Step 2
Disconnect the cables with 37-pin DB connectors from the FMEC card to be removed. Do not forget to mark the connectors or cables for correct reinstallation afterwards.
Step 3
Loosen the front mounting screws (Figure 3).
Step 4
Move the upper ejector up and the lower ejector down to extract the card from the backplane connectors.
Step 5
Carefully remove the card from the shelf.
Related Documentation
•
DOC-7813038= Cisco ONS 15454 SDH Installation and Operations Guide
•
DOC-7813037= Cisco ONS 15454 SDH Troubleshooting and Reference Guide
Obtaining Documentation and Submitting a Service Request
For information on obtaining documentation, submitting a service request, and gathering additional information, see the monthly What's New in Cisco Product Documentation, which also lists all new and revised Cisco technical documentation, at: