Managing Inventory

You can discover the devices using the auto discovery option, and import the details into Cisco VTS. You can also manually create a CSV file with device details, in a prescribed format, and import it into Cisco VTS.

You can create authorization groups and assign devices you import into Cisco VTS, to these groups. Authorization groups are used to group devices with the same credentials (i.e. usernames and passphrases). Once the authorization groups are created, all the devices under these groups may be accessed without specifying the credentials every time they are accessed.

If the same credential are used for accessing all devices, one authorization group can be used. If the credentials are different for different devices, multiple authorization-groups (as many as username/passphrase pairs used by devices) need to be created.

When you do a manual import of devices, the CSV file that is used to import inventory details links the authorization group with a specific device. The applicable authorization group should be used for corresponding device entry in the CSV file.

This chapter has the following sections:

Creating Authorization Groups

Authorization Group is used by Cisco VTS to authenticate or to log in to the device.

To create an authorization group:


    Step 1   Go to Inventory > Authorization Group. The Inventory / Authorization Group window appears.
    Step 2   Click Add (+) icon. The Add Auth Group popup window appears.

    Enter the following details, and click Save:

    • Auth Group Name—The authorization group name.

    • Controller User Name—This is the VTC administrative user name.

    • Device User Name—This is the login user name for the device.

    • Passphrase—This is the login passphrase for the device.

    The authorization group gets added to the Groups table.

    To edit an authorization group, select the Auth Group Name check box and click the Edit icon.

    To delete an authorization group, select the Auth Group Name check box and click the delete (X) icon.


    Performing Auto Discovery

    In the auto discovery option, Cisco VTS automatically discovers the network topology in the data center . You can modify the device details after discovery is complete and add details to the inventory.

    The auto discovery option has the following prerequisites:

    • Link Layer Discovery Protocol (LLDP) has to be enabled on leafs, spine, DCI, and computes. See documentation for the respective devices for details about how to enable LLDP on these devices.


      Note


      As part of Topology discovery, once the compute hosts have been discovered using LLDP, you need to add the username and passphrase to each host entry. This update is required for installation of the host-agent (in case of OpenStack) and any subsequent passphrase change via VTS GUI to go through.


    • A seed device has to be identified, and the IP should be provided. The seed IP is that of one of the leaf or spine devices.

      Note


      You can provide an IPv6 or IPv4 address. If an IPv6 address is given, preference is given to IPv6 address in cases where the devices have both IPv4 and IPv6 addresses, and the IPv6 address will be displayed upon completion of discovery.


    • All devices must have a common set of credentials. These credentials will be used during the discovery process. See Managing Inventory for more information. The credentials must be of the appropriate privilege level on the devices.

    To perform auto discovery:


      Step 1   Go to Inventory > Import and Discovery. The Inventory / Discovery window appears.
      Step 2   Click Discovery . The Discover Network popup window appears.
      Step 3   Enter the Seed Device IP.
      Step 4   Enter the Seed Device User Name.
      Step 5   Enter the Seed Device Passphrase.
      Step 6   Click Start Discovery.
      Step 7   After the auto discovery is complete, the details are displayed in the table. You can use the Bulk Edit option to modify the device details for more than one devices, before you add the devices to inventory, using the Add to Inventory button. To avoid errors, make sure you review the details in the table before you add the devices to Inventory. The Cisco VTS discovery log file is under /var/vts/log. Check for any errors/exceptions in this log file.

      If, during auto discovery, Cisco VTS fails to log into any of the nodes, then the information of the nodes along with the error details can be found in /var/vts/log.

      When you add devices to the inventory using the Add to Inventory button, all devices in the table are added to inventory.

      Note    When two ToRs are configured in vPC and no dual-homed host (connected to those ToRs) is in the VTS inventory, VTS does not correctly identify the vPC. You must add the dual-homed host connected to the ToRs in vPC to the VTS inventory, before provisioning a port on a host connected to the ToRs in vPC.

      Note    Different ESI groups/domains must have different ES-id or system MAC. In other words, duplicate ES-id and system MAC are not allowed among ESI groups. This needs to be guaranteed by providing correct Day Zero configurations for ESI on Cisco Nexus 9000 switches.

      Complete LLDP settings for OpenStack compute host:

      If 'lldpad' application is used on compute for LLDP then the compute may not send interface-name and management-ip-address TLVs by default. These need to be explicitly enabled using the below script. On the other hand, if 'lldpd' were to be used to run LLDP then these TLVs are sent by default and should not require any additional settings prescribed below.

      For 'lldpad', follow below steps to facilitate compute host exchange interface name as Port-ID and management ip address with connected ToR: (Below instructions should go into compute host's recommended Day0 configuration.)

      1. Execute the script:
        for i in `ls /sys/class/net/ | grep eth` ;
        
                  do echo "enabling lldp for interface: $i" ;
        
                  lldptool set-lldp -i $i adminStatus=rxtx  ;
        
                  lldptool -T -i $i -V  sysName enableTx=yes;
        
                  lldptool -T -i $i -V  portDesc enableTx=yes ;
        
                  lldptool -T -i $i -V  sysDesc enableTx=yes;
        
                  lldptool -T -i $i -V sysCap enableTx=yes;
        
                  lldptool -T -i $i -V mngAddr enableTx=yes;
      2. Execute below command:
        # lldptool -T -i <mgmt-if-name> -V mngAddr ipv4=<mgmt-ip> 
        
        For example:
        # lldptool -T -i eth2 -V mngAddr ipv4=192.168.24.185 
      3. Restart lldp daemon.
        service lldpad restart
        If the above steps have not been performed through a startup script during compute startup, then lldp discovery might have already happened and the corresponding ToR might not reflect the mgmt-ip of the compute. To make this happen disable and then enable lldp on the ToR port using below commands:
        1. #config t
        2. (config)#interface ethernet slot/port
        3. (config)#[no] lldp transmit
        4. (config)#[no] lldp receive
        5. (config)#(Optional) show lldp interface ethernet slot/port

      Importing Inventory using CSV File

      The device inventory details need to be uploaded using a CSV file, in the prescribed format. The inventory file is used to define device mappings. If the format is incorrect, Cisco VTS displays an error and provides the details of the error. After a successful import, the topology gets displayed based on the mapping specified in the file.


      Note


      You should be an admin user to download or upload the CSV file. Also, if you are uploading a CSV file for the first time and there are issues uploading the file, then only the partial information is uploaded. You need to delete all the devices from network inventory and re-upload the file after fixing the issues. Or else, you may encounter problems due to the partial upload.

      To download a sample inventory file, click Download Template.


      Note


      In a VMware environment, each time you add a leaf, you must create a corresponding VMware vSphere Distributed Switch (vDS). See the Important Notes Regarding VMware vSphere Distributed Switch (vDS) section for details.

      Note


      While importing inventory with IPv6 addresses for compute hosts in vCenter, the host labels in vCenter (if they have IPv4 addresses) need to be changed. In order to change them, you need to disconnect the host in vCenter, add the host back to the Datastore with IPv6 address.

        Step 1   Go to Inventory > Import and Discovery. The Inventory / Discovery window appears.
        Step 2   Click Import CSV

        The Import Devices popup window appears.

        Step 3   Click Browse to choose the CSV file.

        Click Download Template to download a sample CSV file.

        The CSV file has the following fields:
        • device-name—The device host-name (leaf, spine, DCI)

        • device-ip—IP address for the device (leaf, spine, DCI)

        • device-platform—Can be Cisco Nexus 9000, Cisco Nexus 7000 etc based on the device that is part of the network.

        • device-role—The role that a particular device plays in the data center.
          • leaf—If the device plays the role of a Leaf in the data center.

          • border leaf—If the device plays the role of a Border Leaf in the data center.

          • spine—If the device plays the role of a Spine in the data center.

          • spine-rr—If the Spine plays the role of a Route Reflector in the data center.

          • dci—If the device plays the role of a DCI in the data center.

        • group-tag—Identifier for the group.

        • port-name—Physical port connectivity (local interface)

        • connection-type—server (if connected to compute host); fabric (if connected to another leaf, spine, DCI devices).

        • server-id—Host-name or IP address of the connected device based upon what is configured on the actual host.

        • server-type—virtual-server for computes; baremetal for connections to spine, DCI.

        • interface-name—Physical port connectivity (interface of the connected device)

        • auth-group—Authorization group name, created as part of initialization, with correct credentials.

        • sriov-enabled— If the interface (interface-name) is SR-IOV enabled, this has to be TRUE.

        • physnet-name— Physnet name associated with the interface (interface-name) in OpenStack. If sriov enabled is TRUE, it is the Physnet to be used for SR-IOV. If it is FALSE, the other possibilities are that the port is associated to L2 switch or OVS. In case of OVS, you need to give Physnet intended to be used for OVS.

        Step 4   Browse for the CSV file, and click Import.
        Step 5   After the import operation complete, the details are displayed in the table.

        You can use the Bulk Edit option to modify the device details for more than one devices, before you add the devices to inventory, using the Add to Inventory button. To avoid errors, make sure you review the details in the table before you add the devices to Inventory.

        Click the device name to open the connected devices popup window, which gives details about connected devices for a device.


        Day Zero Configuration for IPv6 Management on vCenter


          Step 1   Make sure you configure IPv6 and default IPv6 route on all Cisco Nexus 9000 and Cisco Nexus 7000 series devices. For example
          Leaf1# show run interface mgmt 0
          
          !Command: show running-config interface mgmt0
          !Time: Tue Apr 11 06:32:35 2018
          
          version 7.3(1)D1(1)
          
          interface mgmt0
          vrf member management
          ip address 172.23.92.16/24
          ipv6 address 2001:422:10e:2005:c00::88/70
          #########  default ipv6 route  #####
          vrf context management
          ip route 0.0.0.0/0 172.23.92.1
          ipv6 route 0::/0 2001:420:10e:2015:c00::1
          Step 2   Log in to the vCenter Server Appliance on the Controller (vCenter 5.5 or 6.0), and configure IPv6 (Network > Address), and save the settings.
          Step 3   For ESXI Host, configure IPV6 through CIMC.

          Viewing the Network Topology

          Topology window provides a view of the data center fabric controlled by Cisco VTS. It displays the leafs, spines, border leafs, DCI, hosts, as well as the software VTEPs. You can get a tenant-based topology view using this feature.

          To view the network topology:


            Step 1   Go to Inventory > Topology. The Inventory / Topology window appears.
            Step 2   Select the VMM from the VMMs drop-down.
            Step 3   Select the tenant for which you need to view the topology, from the Select Tenant drop down list.

            The topology is displayed in the Topology window. You can use the following buttons to control the display:

            • Select node mode

            • Move mode

            • Zoom in / Zoom out / Zoom Selection

            • Fit Stage

            • Full Screen mode

            Hover the mouse cursor over the Topology Setting icon to view Topology Setting popup, where you can change the display icon appearance, and display color.

            Note   

            In case of FEX or vPC, if no host is connected, Cisco VTS will not show the vPC or FEX in the Topology. Also, you might encounter errors.

            The legend provided at the left bottom of the screen help you identify the different types of links (Ethernet/vPC/Multi-Homing/ESI).

            Hover the mouse cursor over the link to view the Info popup, which gives the information about the link.


            Viewing Network Inventory

            The network inventory table displays details about the devices which have been added to the inventory.

            To view the network topology:

            Go to Inventory > Network Inventory. The Inventory / Network Inventory window appears with the Network Inventory table displayed.

            The following details are displayed:

            • Device Name

            • Admin State

            • IP Address

            • Auth Group

            • Device Platform

            • Device Role

            • Group Tag

            • BGP-ASN

            • Templates Attached

            • Sync

            You need to add the BGP-ASN information, loopback interface number, and loopback interface id of every device prior to starting any provisioning.
            Note   

            If you are using VTSR, then the BGP ASN value should be between 0 and 655535.

            You can add network devices via the Network Inventory table. To do this, click the Add (+) icon, and provide the details. You can use this option to add devices to the inventory.

            To edit network device, select the device you want to edit and click the Edit icon.

            To delete network devices from the Network Inventory table, select the device you want to delete and click the Delete (X) icon.

            If there is problem in deleting device, you need make sure that fabric link is cleaned up manually. For example, when Device 1 is connected to Device 2, Inventory has two devices and two fabric links (this can be seen in Fabric Connection tab in Network Inventory)—one from Device 1 to Device 2, and the other from Device 2 to Device 1. While deleting Device 1 from network inventory, cleanup is done for Fabric link Device 1 to Device 2 and for the device from the inventory. The link Device 2 to Device 1 has to be cleaned up manually before you delete.

            It is important that you remove the resource pool before deleting a device.

            You need to discover the devices and add them to the inventory before you bring up the VTSR. If you do these tasks simultaneously, you might encounter errors.

            To recalculate the inventory topology for a particular device, click the redeploy button. See Redeploying Device Inventory for more details.


            Adding Fabric Connection

            To add fabric connection:


              Step 1   Go to Inventory > Network Inventory. The Inventory / Network Inventory window appears with the Network Inventory table displayed.
              Step 2   Click Fabric Connection tab, then click Add (+) icon.

              The Add Fabric Connection popup window appears.

              Step 3   Enter the necessary details and click Save.

              Synchronizing Configuration

              You can check if the device state is in sync with VTS configuration database.

              To check whether the configuration is in sync:


              Note


              This operation can be done only on a device that has the Admin State as Unlocked. If Admin state is Locked, you must change the Admin State to Unlocked, and then do the check-sync operation. Also, the out-of-sync-commit behavior in System Settings must be set to Reject for this feature to be enabled.



                Step 1   Go to Inventory > Network Inventory. The Inventory / Network Inventory page displays the Network Inventory table .
                Step 2   Click the Config Sync link under the Sync column, for the device.

                If the configuration is in sync with the VTS database, the green In Sync icon is displayed.

                If the configuration is not in sync with the device, you will get an option to compare the configuration. You can compare the actual device configuration with the VTS configuration, and can view the diff in compare-config popup. You can also use the copy to clipboard option to copy and paste the configuration in a text editor. To synchronize the configuration, you can use the following options:
                • sync-from—Synchronize the VTS configuration by pulling configuration from the device.

                • sync-to—Synchronize the VTS configuration by pushing configuration to the device.

                Note    If switchname (switch hostname) is changed in the switch CLI, the sync to option will not work. The switchname has to be the same as the value in the VTS inventory.

                Viewing Host Inventory

                You can view the details of the hosts connected to the switches.

                To view host inventory details:


                  Step 1   Go to Inventory > Host Inventory. The Inventory / Host Inventory page appears. The Host Inventory page has two tabs—Virtual Servers and Baremetals. By default, the page displays Virtual Server details.
                  Step 2   To view host details on Virtual Servers, select the VMM from the Select VMM drop-down, and select the device from the Select Device drop-down list. The following details are displayed:
                  • Host Name

                  • IP Address

                  • Host Type

                  • Associated VMM

                  • Virtual Switch

                  • Interfaces

                  • Installation Status—Shows the installation status.

                  • VTF Mode—Displayed on the top left of the table shows the VTF mode you have chosen in the Administration > System Settings window.

                  Step 3   To view host details on Baremetals, select the Baremetals tab, then select the device from the Select Device drop-down.

                  Adding a new Host on Virtual Servers

                  To add a new host:


                    Step 1   Click the Add (+) icon. The Add New Host popup window appears. It has two tabs—Host Details and Host Interfaces. the Host Details tab is selected by default.
                    Step 2   Enter the following host details:
                    • Host Name—This is mandatory. Only letters numbers, underscore and dashes are allowed. Requires at lease one letter or number.

                    • Host Interface—IPv4/IPv6 address of the host. This is mandatory.

                    • Host IP Address

                    • Device Port Name

                    • User Name

                    • Passphrase

                    • Host Configuration
                      • VMM ID—The VMM ID of the VMM to which you want to associate the host to.

                      • Virtual Switch—The following options exist:
                        • not defined

                        • ovs—If you want to install the VTF host agent on the compute, check the Install VTS agent on save check box.

                        • vtf-l2—VTF is used as an L2 switch. If you choose this option, you need to install VTF in vhost mode. See Cisco VTS Installation Guide for details about installing VTS in vhost mode. After you install VTF in vhost mode, you must refresh the Host Inventory page for the details to get updated here.
                        • vtf-vtep—On OpenStack, you need to install VTF as a vhost, if you choose vtf-vtep.

                        Note   

                        The options displayed here depends on what you have specified in the VTF Mode field in Administration > System Settings and the VMM type.

                        The same host cannot support OVS and L2 at the same time. However, in the same host OVS and L2 can reside together with SR-IOV. Some ports can be SR-IOV ports, and others can have L2 switch or OVS.
                    Step 3   Enter the Host Interface details. At least one interface is mandatory.
                    • Host Interfaces—This is mandatory.

                    • SRIOV Enabled—Choose Yes or No from the drop down to specify whether the interface is SRIOV enabled.

                    • Phys Net— Physnet name associated with the interface. If Sriov Enabled is Yes, it is the Physnet to be used for SR-IOV. If it is No, the other possibilities are that the port is associated to L2 switch or OVS. In case of OVS, you need to give Physnet intended to be used for OVS.

                    • Attached to Device—Choose the device from the drop-down.

                    • Device Port—This is mandatory. Choose the device port from the drop-down.

                    • Group

                      To add more interfaces, use the Add (+) icon.

                    Step 4   Click Save. Host details and at least one interface have to be added for the Save button to be enabled.

                    Adding a new Host on Baremetal

                    To add a host,


                      Step 1   Click the Add (+) icon. The Add New Host popup window appears. It has two tabs—Host Details and Host Interfaces. the Host Details tab is selected by default.
                      Step 2   Enter the Host Name. Only letters numbers, underscore and dashes are allowed. Requires at lease one letter or number.
                      Step 3   Enter the Host IP Address. IPv4/IPv6 address of the host. This is mandatory.
                      Step 4   Enter the Host Interface details. At least one interface is mandatory.
                      • Host Interfaces—This is mandatory.

                      • SRIOV Enabled—Choose Yes or No from the drop down to specify whether the interface is SRIOV enabled.

                      • Phys Net—

                      • Attached to Device—Choose the device from the drop-down.

                      • Device Port—This is mandatory. Choose the device port from the drop-down.

                      • Group—

                        To add more interfaces, use the Add (+) icon.

                      To edit a host from the table, select the Host Name check box corresponding to the device and click the Edit icon. You can also click the port icon in the Interfaces column to open the Edit Host popup. You can also use the Bulk Edit option to make changes to more than one host.

                      You cannot edit hosts on which there are workloads associated.
                      To delete a host from the table, select the Host Name check box corresponding to the device and click the click the Delete (X) icon.
                      Note   

                      To convert a virtual server host to baremetal, delete the host and add it as baremetal.


                      Viewing the VTSR to VTF Mapping

                      Go to Inventory > Virtual Forwarding Groups. The Inventory / Virtual Forwarding Groups window appears.

                      The canvas displays the number of VTFs that are attached to theVTSRs . The table on the right hand side shows the VTFs.


                      SRIOV Support

                      Multiple NIC Cards are supported. The following combinations are supported:
                      • SRIOV + OVS

                      • SRIOV + VTF as L2 Switch

                      • SRIOV + SRIOV

                      SRIOV is supported for OpenStack only. VXLAN, VLAN, and Flat network types are supported.

                      The following Provider network types are supported:
                      • VLAN and Flat provider network

                      • Static VLAN (segmentation ID) is honored for VLAN networks.

                      The default tenant network type is VXLAN.

                      Assigining VLAN Ranges

                      Based on the network_vlan_ranges in OpenStack, at /etc/neutron/plugins/ml2/ml2_conf.ini(Controller node), you need to configure:

                      • Device level and device interface level restricted vlan pool for Cisco Nexus 7000 devices in Cisco VTS.
                      • Device level restricted vlan pool for Cisco Nexus 7000 devices in Cisco VTS.

                      See the Managing Resources chapter for details about assigning VLAN ranges.

                      SRIOV related fields SRIOV Enabled and Phys Net can be edited on Host Interfaces tab in Host Inventory, when you add/modify the host.

                      Migrating from vPC to ESI

                      This section provides details about the generic procedure to migrate from Virtual Port Channel (vPC) to Ethernet Segment Identifier (ESI).


                      Note


                      Before you begin, ensure that the following TCAM regions are carved on Cisco Nexus 9000 series switch:
                      hardware access-list tcam region vpc-convergence 256
                      hardware access-list tcam region arp-ether 256 
                      

                      To migrate from vPC to ESI:


                        Step 1   In case of VTSR HA, bring down the VTSR.
                        Step 2   Upgrade VTS to a version which supports ESI.
                        Step 3   If the TCAM regions, as mentioned above, are not already carved on Cisco Nexus 9000 series switch, add the lines and save as running config.
                        hardware access-list tcam region vpc-convergence 256
                        hardware access-list tcam region arp-ether 256 
                        
                        Note    Do not reboot device (as the TOR will be rebooted in the next step).
                        Step 4   Upgrade TORs to a new Cisco Nexus 9000 image, which has ESI feature. This will automatically cause device to reboot.
                        copy run start
                        install all nxos bootflash:/nxos.7.0.3.I4.1t.bin 
                        
                        Step 5   Upgrade Cisco ASR 9000 series DCIs to an ESI supporting image.
                        Step 6   Once the setup is up then remove feature vPC and configure ESI on the required TORs that you are planning to convert to ESI.

                        Remove vPC

                        no feature vpc

                        Remove other vPC related configuration under port channel and Ethernet Interfaces

                        Remove secondary interface from loopback

                        interface loopback0
                          no ip address 44.44.44.44/32 secondary
                        
                        Enable ESI
                        evpn esi multihoming
                        Create nve
                        interface nve1
                          no shutdown
                          source-interface loopback0
                          host-reachability protocol bgp
                        
                        Enable core links
                        interface Ethernet1/35
                          Description " Connected with Spine"
                          no switchport
                          evpn multihoming core-tracking  <<< Add here
                          ip address 16.1.1.2/24
                          ip router ospf 100 area 0.0.0.0
                          ip pim sparse-mode
                          no shutdown
                        
                        Add Ethernet-segment and system-mac address in the port-channel
                        interface port-channel220
                          switchport mode trunk
                          switchport trunk allowed vlan none
                          ethernet-segment 220
                            system-mac eeee.1111.2222
                        

                        Apply the channel group to the TORs interface which are connected to compute.

                        interface Ethernet1/5
                          switchport trunk allowed vlan none
                          channel-group 220 mode active
                        

                        Verify whether the ESI is up.

                        tor1# show nve ethernet-segment 
                        
                        ESI Database
                        ----------------------------------------
                        ESI: 03aa.bbcc.ddee.ee00.002d,
                           Parent interface: port-channel30,
                          ES State: Up 
                          Port-channel state: U
                          NVE Interface: nve1 
                           NVE State: Up 
                           Host Learning Mode: control-plane
                          Active Vlans: 1001 
                           DF Vlans: 0-4095 
                           Active VNIs: 30001 
                          Number of ES  members: 1 
                          My ordinal: 0 
                          DF timer start time: 00:00:00 
                          Config State: config-applied 
                          DF List: 1.1.1.1  
                          ES route added to L2RIB: True
                          EAD routes added to L2RIB: True
                        ----------------------------------------
                        
                        Step 7   On Cisco VTS, perform a sync-from operation for the TORs that have ESI enabled.
                        Step 8   Redeploy inventory from Cisco VTS only for devices that have new ESI configuration. This is to make sure that Cisco VTS recognizes ESI configuration on Cisco Nexus 9000 series devices. See Redeploying Device Inventory for details.
                        Step 9   Remove the peer links between previous vPC peer TORs (Inventory > Network Inventory > Fabric Connection).
                        Step 10   Add the ESI device group to appropriate functional groups in Admin Domain, and also disable ARP suppression in Admin Domain.
                        Step 11   Upgrade VTSR to the latest image.
                        Step 12   Run the Migration script from the path /opt/cisco/package/vtc/bin/vpc-migration. For an HA setup, run this on the Active VM. For example:
                        root@vtc1:/opt/cisco/package/vtc/bin/vpc-migration# ./VpcEsiMigration.py -u admin -p Cisco123! -s -target esi -dev stb2-tor1 stb2-tor2
                        Where:
                        • – u is the VTS GUI username.

                        • – p is the VTS GUI password. Use a single quote (‘) before and after a password that contains special characters. Especially when the password contains an & character in it.

                        • target esi for the vPC to ESI Migration

                        • stb2-tor1 and stb2-tor2 are the hostname of a pair of TOR devices running ESI Day 0 configuration. Modify the name to fit your own hostnames. Also, run the script for one ESI TOR-pair at a time if there is more than one in your environment.


                        Redeploying Device Inventory

                        You can use the Redeploy feature to recalculate the inventory topology for a particular device. This is important in the context of vPC and ESI.

                        You need to Redeploy the inventory when device day zero configuration changes for:
                        • vPC or ESI. For example, vpc id for a port-channel is changed

                        • port-channel or ether-channel

                        Redeploy triggers the inventory for a device again. Since inventory reads the data from the device model in the database it is important to perform sync-from before doing a Redeploy.


                        Note


                        Redeploy function is different from the sync-from function. Sync-from gets the configurations from the device and updates it in the device model in the database. However, it does not recalculate the topology. That is, the topology would still show old information/configuration. Redeploy recalculates the inventory topology. After you perform a Redeploy, the topology will be updated with the modified configuration.


                        To redeploy device inventory:


                          Step 1   Go to Inventory > Network Inventory, perform a sync-from for the device for which the configuration has changed. See Synchronizing Configuration for more details.
                          Step 2   Select the device, click Redeploy.
                          Note    Redeploy just recalculates the inventory. Existing ports/VMs belonging to old device configurations, would not be updated or redeployed. You might need to delete and recreate the existing ports. We recommend that you use redeploy only if there are no existing ports/router/router interfaces.
                          Note   

                          If you delete devices from the inventory and also deleted VTSR with it, when you redeploy or reload the inventory, VTSR will not show up until it is reloaded or restarted. Power on the VTSR and wait for the registration with VTC to complete.


                          Enabling Static Multi Homing

                          Static multi homing can be enabled on Cisco Nexus 7000 series and Cisco Nexus 9000 series devices. You can enable static multi homing by connecting one compute to two ToRs.

                          When you perform a port attach on VMs attached this compute, the configuration is pushed on both the ToRs. Currently, static multi home feature is supported for two ToRs, that is, one compute can connect only to two ToRs. Static multi homing also builds in high availability where one of the interfaces is an active and the other is a standby.

                          Enabling Static Multi Homing on Cisco Nexus 7000

                          To enable static multi homing on Cisco Nexus 7000 devices:


                            Step 1   Group the interfaces using the Resources > Devices > Interface Groups UI.
                            Step 2   In Host Inventory, add the same tag for both the interfaces that are connected to the host for which you are enabling static multi homing.

                            Enabling Static Multi Homing on Cisco Nexus 9000

                            To enable static multi homing for Cisco Nexus 9000 devices:


                              Step 1   Group the devices using Resources > Devices > Groups UI.
                              Step 2   In Host Inventory, add the same tag for both the devices that are connected to the host for which you are enabling static multi homing.

                              If you have the devices already added to admin domain, you will need to update the admin domain to use the device group instead of individual devices.