Managing
Inventory
You can discover the devices using the auto discovery option, and import the details into Cisco VTS. You can also manually create a CSV file with device details, in a prescribed format, and import it into Cisco VTS.
You can create authorization groups and assign devices you import into Cisco VTS, to these groups. Authorization groups are used to group devices with the same credentials (i.e. usernames and passphrases). Once the authorization groups are created, all the devices under these groups may be accessed without specifying the credentials every time they are accessed.
If the same credential are used for accessing all devices, one authorization group can be used. If the credentials are different for different devices, multiple authorization-groups (as many as username/passphrase pairs used by devices) need to be created.
When you do a manual import of devices, the CSV file that is used to import inventory details links the authorization group with a specific device. The applicable authorization group should be used for corresponding device entry in the CSV file.
This chapter has the following sections:
- Creating Authorization Groups
- Performing Auto Discovery
- Importing Inventory using CSV File
- Viewing the Network Topology
- Viewing Network Inventory
- Viewing Host Inventory
- Viewing the VTSR to VTF Mapping
- SRIOV Support
- Migrating from vPC to ESI
- Redeploying Device Inventory
- Enabling Static Multi Homing
Creating Authorization Groups
Authorization Group is used by Cisco VTS to authenticate or to log in to the device.
To create an authorization group:
Performing Auto Discovery
In the auto discovery option, Cisco VTS automatically discovers the network topology in the data center . You can modify the device details after discovery is complete and add details to the inventory.
The auto discovery option has the following prerequisites:
-
Link Layer Discovery Protocol (LLDP) has to be enabled on leafs, spine, DCI, and computes. See documentation for the respective devices for details about how to enable LLDP on these devices.

Note
As part of Topology discovery, once the compute hosts have been discovered using LLDP, you need to add the username and passphrase to each host entry. This update is required for installation of the host-agent (in case of OpenStack) and any subsequent passphrase change via VTS GUI to go through.
-
A seed device has to be identified, and the IP should be provided. The seed IP is that of one of the leaf or spine devices. 
Note
You can provide an IPv6 or IPv4 address. If an IPv6 address is given, preference is given to IPv6 address in cases where the devices have both IPv4 and IPv6 addresses, and the IPv6 address will be displayed upon completion of discovery.
-
All devices must have a common set of credentials. These credentials will be used during the discovery process. See Managing Inventory for more information. The credentials must be of the appropriate privilege level on the devices.
To perform auto discovery:
Importing Inventory using CSV File
The device inventory details need to be uploaded using a CSV file, in the prescribed format. The inventory file is used to define device mappings. If the format is incorrect, Cisco VTS displays an error and provides the details of the error. After a successful import, the topology gets displayed based on the mapping specified in the file.
![]() Note | You should be an admin user to download or upload the CSV file. Also, if you are uploading a CSV file for the first time and there are issues uploading the file, then only the partial information is uploaded. You need to delete all the devices from network inventory and re-upload the file after fixing the issues. Or else, you may encounter problems due to the partial upload. |
To download a sample inventory file, click Download Template.
![]() Note | In a VMware environment, each time you add a leaf, you must create a corresponding VMware vSphere Distributed Switch (vDS). See the Important Notes Regarding VMware vSphere Distributed Switch (vDS) section for details. |
![]() Note | While importing inventory with IPv6 addresses for compute hosts in vCenter, the host labels in vCenter (if they have IPv4 addresses) need to be changed. In order to change them, you need to disconnect the host in vCenter, add the host back to the Datastore with IPv6 address. |
| Step 1 | Go to . The Inventory / Discovery window appears. |
| Step 2 | Click
Import
CSV
The Import Devices popup window appears. |
| Step 3 | Click
Browse to choose the CSV file.
Click Download Template to download a sample CSV file.
|
| Step 4 | Browse for the CSV file, and click Import. |
| Step 5 | After the
import operation complete, the details are displayed in the table.
You can use the Bulk Edit option to modify the device details for more than one devices, before you add the devices to inventory, using the Add to Inventory button. To avoid errors, make sure you review the details in the table before you add the devices to Inventory. Click the device name to open the connected devices popup window, which gives details about connected devices for a device. |
Day Zero Configuration for IPv6 Management on vCenter
| Step 1 | Make sure
you configure IPv6 and default IPv6 route on all Cisco Nexus 9000 and Cisco
Nexus 7000 series devices. For example
Leaf1# show run interface mgmt 0 !Command: show running-config interface mgmt0 !Time: Tue Apr 11 06:32:35 2018 version 7.3(1)D1(1) interface mgmt0 vrf member management ip address 172.23.92.16/24 ipv6 address 2001:422:10e:2005:c00::88/70 ######### default ipv6 route ##### vrf context management ip route 0.0.0.0/0 172.23.92.1 ipv6 route 0::/0 2001:420:10e:2015:c00::1 |
| Step 2 | Log in to the vCenter Server Appliance on the Controller (vCenter 5.5 or 6.0), and configure IPv6 (Network > Address), and save the settings. |
| Step 3 | For ESXI Host, configure IPV6 through CIMC. |
Viewing the Network Topology
To view the network topology:
| Step 1 | Go to . The Inventory / Topology window appears. | ||
| Step 2 | Select the VMM from the VMMs drop-down. | ||
| Step 3 | Select the
tenant for which you need to view the topology, from the
Select
Tenant drop down list.
The topology is displayed in the Topology window. You can use the following buttons to control the display: Hover the mouse cursor over the Topology Setting icon to view Topology Setting popup, where you can change the display icon appearance, and display color.
|
Viewing Network Inventory
The network inventory table displays details about the devices which have been added to the inventory.
To view the network topology:
The following details are displayed:
You can add network devices via the Network Inventory table. To do this, click the Add (+) icon, and provide the details. You can use this option to add devices to the inventory. To edit network device, select the device you want to edit and click the Edit icon. To delete network devices from the Network Inventory table, select the device you want to delete and click the Delete (X) icon. If there is problem in deleting device, you need make sure that fabric link is cleaned up manually. For example, when Device 1 is connected to Device 2, Inventory has two devices and two fabric links (this can be seen in Fabric Connection tab in Network Inventory)—one from Device 1 to Device 2, and the other from Device 2 to Device 1. While deleting Device 1 from network inventory, cleanup is done for Fabric link Device 1 to Device 2 and for the device from the inventory. The link Device 2 to Device 1 has to be cleaned up manually before you delete. It is important that you remove the resource pool before deleting a device. You need to discover the devices and add them to the inventory before you bring up the VTSR. If you do these tasks simultaneously, you might encounter errors. To recalculate the inventory topology for a particular device, click the redeploy button. See Redeploying Device Inventory for more details. |
Adding Fabric Connection
To add fabric connection:
Synchronizing Configuration
You can check if the device state is in sync with VTS configuration database.
To check whether the configuration is in sync:
![]() Note | This operation can be done only on a device that has the Admin State as Unlocked. If Admin state is Locked, you must change the Admin State to Unlocked, and then do the check-sync operation. Also, the out-of-sync-commit behavior in System Settings must be set to Reject for this feature to be enabled. |
| Step 1 | Go to . The Inventory / Network Inventory page displays the Network Inventory table . | ||
| Step 2 | Click the
Config
Sync link under the Sync column, for the device.
If the configuration is in sync with the VTS database, the green In Sync icon is displayed.
|
Viewing Host Inventory
You can view the details of the hosts connected to the switches.
To view host inventory details:
| Step 1 | Go to . The Inventory / Host Inventory page appears. The Host Inventory page has two tabs—Virtual Servers and Baremetals. By default, the page displays Virtual Server details. |
| Step 2 | To view host details on Virtual Servers, select the VMM from the Select VMM drop-down, and select the device from the Select Device drop-down list. The following details are displayed: |
| Step 3 | To view host details on Baremetals, select the Baremetals tab, then select the device from the Select Device drop-down. |
Adding a new Host on Virtual Servers
To add a new host:
| Step 1 | Click the Add (+) icon. The Add New Host popup window appears. It has two tabs—Host Details and Host Interfaces. the Host Details tab is selected by default. | ||
| Step 2 | Enter the
following host details:
| ||
| Step 3 | Enter the
Host Interface details. At least one interface is mandatory.
| ||
| Step 4 | Click Save. Host details and at least one interface have to be added for the Save button to be enabled. |
Adding a new Host on Baremetal
To add a host,
| Step 1 | Click the Add (+) icon. The Add New Host popup window appears. It has two tabs—Host Details and Host Interfaces. the Host Details tab is selected by default. | ||
| Step 2 | Enter the Host Name. Only letters numbers, underscore and dashes are allowed. Requires at lease one letter or number. | ||
| Step 3 | Enter the Host IP Address. IPv4/IPv6 address of the host. This is mandatory. | ||
| Step 4 | Enter the
Host Interface details. At least one interface is mandatory.
To edit a host from the table, select the Host Name check box corresponding to the device and click the Edit icon. You can also click the port icon in the Interfaces column to open the Edit Host popup. You can also use the Bulk Edit option to make changes to more than one host. You cannot edit hosts on which there are workloads associated.
|
Viewing the VTSR to VTF Mapping
The canvas displays the number of VTFs that are attached to theVTSRs . The table on the right hand side shows the VTFs. |
SRIOV Support
SRIOV is supported for OpenStack only. VXLAN, VLAN, and Flat network types are supported.
The default tenant network type is VXLAN.
Assigining VLAN Ranges
Based on the network_vlan_ranges in OpenStack, at /etc/neutron/plugins/ml2/ml2_conf.ini(Controller node), you need to configure:
- Device level and device interface level restricted vlan pool for Cisco Nexus 7000 devices in Cisco VTS.
- Device level restricted vlan pool for Cisco Nexus 7000 devices in Cisco VTS.
See the Managing Resources chapter for details about assigning VLAN ranges.
SRIOV related fields SRIOV Enabled and Phys Net can be edited on Host Interfaces tab in Host Inventory, when you add/modify the host.
Migrating from vPC to ESI
This section provides details about the generic procedure to migrate from Virtual Port Channel (vPC) to Ethernet Segment Identifier (ESI).
![]() Note | Before you begin, ensure that the following TCAM regions are carved on Cisco Nexus 9000 series switch: |
hardware access-list tcam region vpc-convergence 256 hardware access-list tcam region arp-ether 256
To migrate from vPC to ESI:
| Step 1 | In case of VTSR HA, bring down the VTSR. | ||||||||||||||||||
| Step 2 | Upgrade VTS to a version which supports ESI. | ||||||||||||||||||
| Step 3 | If the TCAM
regions, as mentioned above, are not already carved on Cisco Nexus 9000 series
switch, add the lines and save as running config.
hardware access-list tcam region vpc-convergence 256 hardware access-list tcam region arp-ether 256
| ||||||||||||||||||
| Step 4 | Upgrade TORs
to a new Cisco Nexus 9000 image, which has ESI feature. This will automatically
cause device to reboot.
copy run start install all nxos bootflash:/nxos.7.0.3.I4.1t.bin | ||||||||||||||||||
| Step 5 | Upgrade Cisco ASR 9000 series DCIs to an ESI supporting image. | ||||||||||||||||||
| Step 6 | Once the setup
is up then remove feature vPC and configure ESI on the required TORs that you
are planning to convert to ESI.
| ||||||||||||||||||
| Step 7 | On Cisco VTS, perform a sync-from operation for the TORs that have ESI enabled. | ||||||||||||||||||
| Step 8 | Redeploy inventory from Cisco VTS only for devices that have new ESI configuration. This is to make sure that Cisco VTS recognizes ESI configuration on Cisco Nexus 9000 series devices. See Redeploying Device Inventory for details. | ||||||||||||||||||
| Step 9 | Remove the peer links between previous vPC peer TORs (Inventory > Network Inventory > Fabric Connection). | ||||||||||||||||||
| Step 10 | Add the ESI device group to appropriate functional groups in Admin Domain, and also disable ARP suppression in Admin Domain. | ||||||||||||||||||
| Step 11 | Upgrade VTSR to the latest image. | ||||||||||||||||||
| Step 12 | Run the
Migration script from the path /opt/cisco/package/vtc/bin/vpc-migration. For an
HA setup, run this on the Active VM.
For example:
root@vtc1:/opt/cisco/package/vtc/bin/vpc-migration# ./VpcEsiMigration.py -u admin -p Cisco123! -s -target esi -dev stb2-tor1 stb2-tor2
|
Redeploying Device Inventory
You can use the Redeploy feature to recalculate the inventory topology for a particular device. This is important in the context of vPC and ESI.
Redeploy triggers the inventory for a device again. Since inventory reads the data from the device model in the database it is important to perform sync-from before doing a Redeploy.
![]() Note | Redeploy function is different from the sync-from function. Sync-from gets the configurations from the device and updates it in the device model in the database. However, it does not recalculate the topology. That is, the topology would still show old information/configuration. Redeploy recalculates the inventory topology. After you perform a Redeploy, the topology will be updated with the modified configuration. |
To redeploy device inventory:
| Step 1 | Go to Inventory > Network Inventory, perform a sync-from for the device for which the configuration has changed. See Synchronizing Configuration for more details. | ||||
| Step 2 | Select the
device, click Redeploy.
|
Enabling Static Multi Homing
Static multi homing can be enabled on Cisco Nexus 7000 series and Cisco Nexus 9000 series devices. You can enable static multi homing by connecting one compute to two ToRs.
When you perform a port attach on VMs attached this compute, the configuration is pushed on both the ToRs. Currently, static multi home feature is supported for two ToRs, that is, one compute can connect only to two ToRs. Static multi homing also builds in high availability where one of the interfaces is an active and the other is a standby.
Enabling Static Multi Homing on Cisco Nexus 7000
To enable static multi homing on Cisco Nexus 7000 devices:
Enabling Static Multi Homing on Cisco Nexus 9000
To enable static multi homing for Cisco Nexus 9000 devices:
| Step 1 | Group the devices using Resources > Devices > Groups UI. |
| Step 2 | In Host
Inventory, add the same tag for both the devices that are connected to the host
for which you are enabling static multi homing.
If you have the devices already added to admin domain, you will need to update the admin domain to use the device group instead of individual devices. |