What Is the CPT System?
The CPT System is the first Packet-Optical Transport System (P-OTS) built on standards-based MPLS-TP technology. The CPT System unifies both packet and transport technologies, giving a strong foundation for next-generation transport. The CPT System is designed to support transport applications so that service providers can continue to offer existing transport services while enabling new packet services.
The existing transport networks must be migrated from TDM networks to packet transport networks because the packet-based services dominate the overall network traffic. Next-generation transport networks enable and support new mesh, multipoint, and multidirectional services. By deploying packet transport networks, you can benefit from:
- Statistical multiplexing
- Dynamic bandwidth allocation
- QoS
Note
CPT System is displayed as “PT System” in the Prime Optical user interface.
The CPT System provides the following benefits:
- Ensures a smooth and efficient transition from TDM networks to packet transport networks
- Enables you to deploy new packet transport networks
- Provides architectural flexibility with support for:
–
MPLS-TP
–
IP/MPLS
–
Carrier Ethernet transport
- Provides data plane and control plane flexibility in network deployments
- Enables service providers to provide the following for residential and business customers:
–
Mobile back-haul
–
Ethernet services
–
TDM services
The following sections describe related Prime Optical features and options:
Understanding User Privileges and Tasks
This section describes the user privileges, CPT System tasks, and new UI options.
Table 13-1 describes the Prime Optical default user profiles and the privileges associated with each profile.
Table 13-1 User Privileges
|
|
SuperUser |
- Tasks—Allowed to perform all the tasks listed in Table 13-2 .
- UI Options—All the UI options are visible.
|
NetworkAdmin |
- Tasks—Allowed to perform all the tasks listed in Table 13-2 .
- UI Options—All the UI options are visible.
|
SysAdmin |
- Tasks—Cannot perform any of the tasks listed in Table 13-2 .
- UI Options—None of the UI options are visible.
|
Provisioner |
- Tasks—Allowed to perform all the tasks listed in Table 13-2 .
- UI Options—All the UI options are visible.
|
Operator |
- Tasks—Cannot perform any of the tasks listed in Table 13-2 .
- UI Options—All the UI options are visible.
|
Table 13-2 describes the CPT System tasks and UI options.
Note
CPT System is displayed as “PT System” in the Prime Optical user interface.
Table 13-2 CPT System Tasks and UI Options
|
|
For More Information, See...
|
Viewing the PT System configuration mode |
NE Explorer > PT System > Provisioning > Configuration Mode |
Configuration Mode |
Launching CPT IOS CLI |
NE Explorer > PT System > Provisioning > IOS CLI |
IOS CLI |
Configuring SyncE ports |
NE Explorer > PT System > Provisioning > Timing |
Timing |
CPT System
This section describes the following:
Understanding CPT Cards
Note
CPT System is displayed as “PT System” in the Prime Optical user interface.
The CPT System is supported on the CPT 200 and CPT 600 chassis. The CPT 200 chassis consists of two service slots and has a 160-GB switch capacity. The CPT 600 chassis consists of six service slots and has a 480-GB switch capacity.
The following are the CPT cards:
The PTSA_GE panel is a standalone unit and can be connected to the PT System. The PTSA_GE panel enables the number of ports to be scaled on the CPT System. For more information, see Slot Properties—PTSA_GE.
PTF_10GE_4 and PT_10GE_4 cards are supported on the CPT 200 and CPT 600 platforms. The CPT System complies with RoHS-6 standards.
The following system configuration is recommended on the CPT 200 shelf:
- Standalone PTF_10GE_4 card
- Standalone TNC, TNCE, TSC, or TSCE card
- One or more PTSA_GE panels
The following system configuration is recommended on the CPT 600 shelf:
- Redundant PTF_10GE_4 cards
- One PT_10GE_4 card
- Redundant TNC, TNCE, TSC, or TSCE cards
- One or more PTSA_GE panels
The CPT System integrates DWDM, OTN, Ethernet, and standards-based MPLS-TP in a single system. The CPT System also integrates with other Cisco platforms such as the ONS 15454, and Carrier Routing System to deliver a combined IP/MPLS and MPLS-TP solution under a single control plane, forwarding mechanism, and NMS. This solution enables you to interoperate with existing IP/MPLS networks.
The CPT System works in the metro edge and access portion of the network, providing an integrated packet and transport solution. The CPT System significantly reduces rack space and power consumption.
The following sections describe the CPT cards:
Overview of the CPT System Property Sheet
For descriptions of the CPT System, CPT cards, and LACP, see the following sections:
Note
CPT System is displayed as “PT System” in the Prime Optical user interface.
When you choose Configuration > NE Explorer for the ONS 15454 SONET or ONS 15454 SDH, the window that Prime Optical displays consists of a tree on the left side and a properties pane on the right. The tree provides a hierarchical view of the NEs physical shelves and slots. In the tree, click PT System to open the PT System property sheet. The properties pane shows information about the PT System.
This section includes:
When you open the PT System, the default property displayed is the Identification property.
Identification
The Identification property displays the list of CPT cards managed by the PT System. The Identification property displays the details in a table. The table has two columns:
- Physical Location—Displays the following details:
–
Shelf number
–
Slot number
–
Fan-Out-Group (FOG) number
- Module Name—Displays the name of the card or panel.
Configuration Mode
The Configuration Mode property is display only. The Operation Mode field in the Configuration Mode property displays the operation mode of the PT System. The operation mode can be IOS Mode or CTC Mode.
Note
If you switch from CTC Mode to IOS Mode, all the Layer 2 services are deleted automatically.
In IOS Mode, you cannot perform the following operations:
- Create Layer 2 services
- View Layer 2 services
- Modify Layer 2 services
- Trace Layer 2 services
- Troubleshoot Layer 2 services
Note
The Configuration Mode is displayed as IOS Mode in Prime Optical Release 10.6 because the IOS Mode contains the CPT device. You do not have to configure the CPT device in IOS Mode.
IOS CLI
Monitor Layer 2 service level performance counters using the IOS CLI property. From the PT System IOS CLI Interface area, click Launch CLI.
- If you are using a Linux operating system, an xterm window runs a Telnet tunnel connection to the active PTF_10GE_4 card IOS console of the PT System.
- If you are using a Windows operating system and if Telnet is installed on the PC running the Prime Optical client, Telnet is directly used to open the tunnel connection.
From the IOS CLI window, you can run the show interfaces command. You can also run other Cisco IOS commands on the IOS CLI, but it depends on the security settings and the account active on the PT System.
Timing
A separate external TDM circuit is required to provide synchronized timing to multiple remote NEs for packet transport networks such as the CPT System. The Synchronous Ethernet (SycnE) feature addresses this requirement by providing effective timing to the remote NEs through a packet network without using an external circuit for timing.
The Timing property allows you to configure SyncE ports.
Table 13-3 describes the Timing property Table fields.
Table 13-3 Field Descriptions for the Timing Property Table
|
|
Card |
Display only. Displays the card number and slot number. |
Port |
Display only. Displays the port number (n-n) and rate. |
ProvidesSync |
Display only. Selects the port automatically after the port is used as a clock source. |
SyncMsgIn |
Sets the EnableSync card parameter. Enables synchronization status messages, which allow the node to choose the best timing source. |
Admin SSM In |
Overrides the synchronization status message (SSM) and the synchronization traceability unknown (STU) value. If the node does not receive an SSM signal, it defaults to STU. The options are:
- PRS—Primary reference source (Stratum 1)
- ST2—Stratum 2
- TNC—Transit node clock
- ST3E—Stratum 3E
- ST3—Stratum 3
- SMC-SONET minimum clock
- ST4—Stratum 4
- DUS—Do not use for timing synchronization
- RES—Reserved; quality level set by the user
|
Send DoNotUse |
When checked, sends a DUS message as the QL value. |
ESMC Enable |
Check the check box on the port where you want to enable SyncE. You can select the clock source among the Ethernet Synchronization Message Channel (ESMC) enabled ports. To select the clock source among the OTN ports, do not check the check box. |
Understanding the CPT System Alarms
In Prime Optical 10.6, new alarms have been introduced for the CPT System. This section includes:
Equipment Alarms
Table 13-4 describes the equipment alarms.
Table 13-4 Equipment Alarms
|
|
|
CUTOVER |
The Planned Switch Over alarm is raised when a planned switchover of the PTF_10GE_4 card occurs. |
EQPT |
RESOURCES_LOW |
The Running Low on Resources alarm is raised if the resource memory is very low or if more resources cannot be configured. |
EQPT |
RESOURCES_OVER |
The No More Resources Available alarm is raised if the resource memory is used completely or if configuring of resources is not possible. |
EQPT |
Satellite Alarms
Table 13-5 lists and describes the satellite alarms. The satellite alarms listed in the following table are raised when satellite communication is impacted between PTF_10GE_4, PT_10GE_4, and PTSA_GE.
Table 13-5 Satellite Alarms
|
|
SAT_DISCOVERY_FAIL |
Satellite panel discovery failure. |
SAT_ACT_LINK_FAIL |
Satellite panel active link failure. |
SAT_COMM_FAIL |
Satellite panel communication failure. |
SAT_IMPROPER_CONFIG |
Satellite panel improper configuration. |
SAT_FAN_MEA |
Satellite panel fan mismatch of equipment and attributes. |
SAT_FAN_FAIL |
Satellite panel fan failure. |
SAT_FAN_DEGRADE |
Satellite panel partial fan failure. |
SAT_FAN_MFGMEM |
Satellite panel fan manufacturing data memory (EEPROM) failure. |
SAT_FAN_MISSING |
Satellite panel fan unit is missing. |
SAT_IHITEMP |
Satellite panel industrial high temperature. |
SAT_HITEMP |
Satellite panel high temperature. |
SAT_BAT_FAIL |
Satellite panel battery failure. |
SAT_BAT_FAIL_A |
Satellite panel battery A failure. |
SAT_BAT_FAIL_B |
Satellite panel battery B failure. |
Port Alarms
Table 13-6 describes the port alarms.
Table 13-6 Port Alarms
|
|
Required on PTF_10GE_4 Trunk Ports
|
Required on PT_10GE_4 Client
|
Required on PTSA_GE 1G Port
|
Required on PTSA_GE Client
|
MAC_MOVE—MAC address is relearned on a different port in the same bridge domain |
Yes |
Yes |
Yes |
Yes |
— |
SAT_ACTIVE_LINK_FAIL—Satellite panel active link failure |
Yes |
Yes |
Yes |
— |
— |
Legacy Alarms on PTF_10GE_4 and PT_10GE_4
|
SYNCLOSS |
Yes |
Yes |
Yes |
Yes |
Yes |
SIGLOSS |
Yes |
Yes |
Yes |
Yes |
Yes |
LOCAL-FAULT |
Yes |
Yes |
Yes |
No |
Yes |
REMOTE-FAULT |
Yes |
Yes |
Yes |
No |
Yes |
SF |
No |
Yes |
No |
No |
No |
SD |
No |
Yes |
No |
No |
No |
FEC-MISM |
No |
Yes |
No |
No |
No |
UNC-WORD |
No |
Yes |
No |
No |
No |
GCC-EOC |
No |
Yes |
No |
No |
No |
HELLO |
— |
Yes |
— |
— |
— |
ISIS-ADJ-FAIL |
No |
No |
No |
No |
No |
PROV-MISMATCH |
Yes |
Yes |
Yes |
Yes |
Yes |
TRAIL-SIGNAL |
— |
— |
— |
— |
— |
LMP-SD |
No |
No |
No |
No |
No |
LMP-SF |
No |
No |
No |
No |
No |
LMP-UNALLOC |
No |
No |
No |
No |
No |
LMP-FAIL |
No |
No |
No |
No |
No |
UNC-WORD |
No |
Yes |
No |
No |
No |
LOF |
Yes |
Yes |
Yes |
Yes |
Yes |
LOS |
Yes |
Yes |
Yes |
Yes |
Yes |
OUT-OF-SYNC |
Yes |
Yes |
Yes |
Yes |
Yes |
OTUK-IAE |
No |
Yes |
No |
No |
No |
OTUK-SD |
No |
Yes |
No |
No |
No |
OTUK-SF |
No |
Yes |
No |
No |
No |
OTUK-TIM |
No |
Yes |
No |
No |
No |
LOM |
No |
Yes |
No |
No |
No |
OTUK-LOF |
No |
Yes |
No |
No |
No |
FEC-MISM |
No |
Yes |
No |
No |
No |
OTUK-AIS |
No |
Yes |
No |
No |
No |
ODUK-BDI-PM |
— |
Yes |
— |
— |
— |
OTUK-BDI |
— |
Yes |
— |
— |
— |
ODUK-SD-PM |
— |
Yes |
— |
— |
— |
ODUK-SF-PM |
— |
Yes |
— |
— |
— |
ODUK-TIM-PM |
— |
Yes |
— |
— |
— |
ODUK-AIS-PM |
— |
Yes |
— |
— |
— |
ODUK-LCK-PM |
— |
Yes |
— |
— |
— |
ODUK-OCI-PM |
— |
Yes |
— |
— |
— |
HI-RXPOWER |
Yes |
Yes |
Yes |
Yes |
Yes |
LO-RXPOWER |
Yes |
Yes |
Yes |
Yes |
Yes |
HI-TXPOWER |
Yes |
Yes |
Yes |
Yes |
Yes |
LO-TXPOWER |
Yes |
Yes |
Yes |
Yes |
Yes |
HI-LASERBIAS |
Yes |
Yes |
Yes |
Yes |
Yes |
LO-LASERBIAS |
Yes |
Yes |
Yes |
Yes |
Yes |
HI-LASERTEMP |
Yes |
Yes |
Yes |
Yes |
Yes |
LO-LASERTEMP |
Yes |
Yes |
Yes |
Yes |
Yes |
HI-PELTIER |
— |
— |
— |
— |
— |
LO-PELTIER |
— |
— |
— |
— |
— |
HI-XCVRVOLT |
— |
— |
— |
— |
— |
LO-XCVRVOLT |
— |
— |
— |
— |
— |
WVL-MISMATCH |
No |
Yes |
No |
No |
No |
PORT-COMM-FAI |
— |
— |
— |
— |
— |
DSP-FAIL |
— |
— |
— |
— |
— |
UT-COMM-FAIL |
— |
— |
— |
— |
— |
UT-FAIL |
— |
— |
— |
— |
— |
LASER-OFF-WVL |
— |
— |
— |
— |
— |
TX-OFF-NON-CI |
Yes |
Yes |
Yes |
Yes |
Yes |
PORT-CODE-MIS |
— |
— |
— |
— |
— |
PORT-COMM-FAI |
— |
— |
— |
— |
— |
PORT-MISMATCH |
— |
— |
— |
— |
— |
PORT-MISSING |
— |
— |
— |
— |
— |
LPBKTERMINAL |
Yes |
Yes |
Yes |
Yes |
Yes |
LPBKFACILITY |
Yes |
Yes |
Yes |
Yes |
Yes |
HELLO |
— |
— |
— |
— |
— |
ISIS-ADJ-FAIL |
— |
— |
— |
— |
— |
AS-CMD |
— |
— |
— |
— |
— |
AS-MT |
— |
— |
— |
— |
— |
NEIGHBOR-ADJACENCY-FAILURE |
Yes |
Yes |
Yes |
Yes |
No |
LINK-FLAPPING |
Yes |
Yes |
Yes |
Yes |
No |
MIS-CONFIGURED-SEGMENT |
Yes |
Yes |
Yes |
Yes |
No |
VLB-FAILED |
Yes |
Yes |
Yes |
Yes |
No |
VLB-DEACTIVATED |
Yes |
Yes |
Yes |
Yes |
No |
PRIMARY-EDGE-PORT-ELECTED |
Yes |
Yes |
Yes |
Yes |
No |
SECONDARY-EDGE-PORT-ELECTED |
Yes |
Yes |
Yes |
Yes |
No |
SEGMENT-HEALED |
Yes |
Yes |
Yes |
Yes |
No |
STNC-GENERATED |
Yes |
Yes |
Yes |
Yes |
No |
VLB-ACTIVATED |
Yes |
Yes |
Yes |
Yes |
No |
VLB-TRIGGER-DELAY-ACTIVE |
Yes |
Yes |
Yes |
Yes |
No |
Service Alarms
Table 13-7 describes the service alarms.
Table 13-7 Service Alarms
|
|
|
|
WKG_PW_CP_DOWN |
Working pseudowire control plane down alarm. This alarm is raised on the port if the working pseudowire control plane is down. |
Port/PTS_CHANNEL_GROUP |
PRT_PW_CP_DOWN |
Protect pseudowire control plane down alarm. This alarm is raised on the port if the protect pseudowire control plane is down. |
Port/PTS_CHANNEL_GROUP |
WKG_PW_CC_DOWN |
Working pseudowire continuity check down alarm. This alarm is raised on the port if the working pseudowire continuity check is down. |
Port/PTS_CHANNEL_GROUP |
PRT_PW_CC_DOWN |
Protect pseudowire continuity check down alarm. This alarm is raised on the port if the protect pseudowire continuity check is down. |
Port/PTS_CHANNEL_GROUP |
PW_ WKSWPR |
Pseudowire traffic switched to protection alarm. This alarm is raised on the port when the pseudowire traffic is switched from the working path to the protected path. |
Port/PTS_CHANNEL_GROUP |
WKG_PW_LOC_AC_TX_FLT |
Working pseudowire local AC Tx port fault alarm. This alarm is raised when a working pseudowire local AC Tx port fault is detected. |
Port/PTS_CHANNEL_GROUP |
PRT_PW_LOC_AC_TX_FLT |
Protect pseudowire local AC Tx port fault alarm. This alarm is raised when a protect pseudowire local AC Tx port fault is detected. |
Port/PTS_CHANNEL_GROUP |
WKG_PW_LOC_AC_RX_FLT |
Working pseudowire local AC Rx port fault alarm. This alarm is raised when a working pseudowire local AC Rx port fault is detected. |
Port/PTS_CHANNEL_GROUP |
PRT_PW_LOC_AC_RX_FLT |
Protect pseudowire local AC Rx port fault alarm. This alarm is raised when a protect pseudowire local AC Rx port fault is detected. |
Port/PTS_CHANNEL_GROUP |
WKG_PW_REM_AC_TX_FLT |
Working pseudowire remote AC Tx port fault alarm. This alarm is raised when a working pseudowire remote AC Tx port fault is detected. |
Port/PTS_CHANNEL_GROUP |
PRT_PW_REM_AC_TX_FLT |
Protect pseudowire remote AC Tx port fault alarm. This alarm is raised when a protect pseudowire remote AC Tx port fault is detected. |
Port/PTS_CHANNEL_GROUP |
WKG_PW_REM_AC_RX_FLT |
Working pseudowire remote AC Rx port fault alarm. This alarm is raised when a working pseudowire remote AC Rx port fault is detected. |
Port/PTS_CHANNEL_GROUP |
PRT_PW_REM_AC_RX_FLT |
Protect pseudowire remote AC Rx port fault alarm. This alarm is raised when the protect pseudowire remote AC Rx port fault is detected. |
Port/PTS_CHANNEL_GROUP |
|
WKG_LOC_PW_NOT_FWD |
Working local pseudowire not forwarding alarm. This alarm is raised when the local working pseudowire is not forwarding traffic. |
PTS** |
PRT_LOC_PW_NOT_FWD |
Protected local pseudowire not forwarding alarm. This alarm is raised when the local protect pseudowire is not forwarding traffic. |
PTS** |
WKG_REM_PW_NOT_FWD |
Working remote pseudowire not forwarding alarm. This alarm is raised when the remote working pseudowire is not forwarding traffic. |
PTS** |
PRT_REM_PW_NOT_FWD |
Protect remote pseudowire not forwarding alarm. This alarm is raised when the remote protect pseudowire is not forwarding the traffic. |
PTS** |
|
TP_TUNNEL_DOWN |
MPLS-TP tunnel down alarm. This alarm is raised when the working or protect LSP is down. |
PTS** |
WKG_LSP_DOWN |
Working LSP down alarm. This alarm is raised on the port if the working LSP is down. |
Port/PTS_CHANNEL_GROUP |
PRT_LSP_DOWN |
Protect LSP down alarm. This alarm is raised on the port if the protect LSP is down. |
Port/PTS_CHANNEL_GROUP |
WKG_LSP_AIS |
Working LSP alarm indication signal. This alarm is raised when the working LSP receives an LSP alarm indication signal. |
Port/PTS_CHANNEL_GROUP |
PRT_LSP_AIS |
Protect LSP alarm indication signal. This alarm is raised when the protect LSP receives an LSP alarm indication signal. |
Port/PTS_CHANNEL_GROUP |
WKG_LSP_RDI |
Working LSP remote defect indication. This alarm is raised when the working LSP receives an LSP remote defect indication. |
Port/PTS_CHANNEL_GROUP |
PRT_LSP_RDI |
Protect LSP remote defect indication. This alarm is raised when the protect LSP receives an LSP remote defect indication. |
Port/PTS_CHANNEL_GROUP |
BFD_DOWN |
BFD down alarm. This alarm is raised when the BFD is not enabled on the port. |
Port/PTS_CHANNEL_GROUP |
TP_WKSPWR |
TP traffic switched to protection alarm. This alarm is raised when the MPSL-TP traffic switches from working pseudowire to protected pseudowire. |
Port/PTS_CHANNEL_GROUP |
WKG_TP_LOCKOUT |
Working TP lockout alarm. This alarm is raised when the lockout request is set to ON for the working MPLS-TP. |
Port/PTS_CHANNEL_GROUP |
PRT_TP_LOCKOUT |
Protect TP lockout alarm. This alarm is raised when the lockout request is set to ON for the protect MPLS-TP. |
Port/PTS_CHANNEL_GROUP |
WKG_LSP_LDI |
Working LSP link defect indication. This alarm is raised when the working LSP receives an LSP link defect indication. |
Port/PTS_CHANNEL_GROUP |
PRT_LSP_LDI |
Protect LSP link defect indication. This alarm is raised when the protect LSP receives an LSP link defect indication. |
Port/PTS_CHANNEL_GROUP |
WKG_LSP_LKR |
Working LSP lock report alarm. This alarm is raised when an interface is administratively shutdown on a working path in an MPLS-TP tunnel. |
Port/PTS_CHANNEL_GROUP |
PRT_LSP_LKR |
Protect LSP lock report alarm. This alarm is raised when an interface is administratively locked and a lockout request (LKR) is generated on the nearest reachable endpoint. |
Port/PTS_CHANNEL_GROUP |
|
EFP_FAIL |
EFP failed alarm. This alarm is raised when the EFP fails due to incomplete hardware provisioning or when the interface on which the EFP is present goes down. |
Port |
|
TE_TUNNEL_DOWN |
TE tunnel down alarm. This alarm is raised when the working and protected MPLS-LSP goes down. |
PTS** |