Powering on the Router

This chapter describes how to connect the power modules in the chassis and to power on the router.

Power Supply Overview

On the Cisco 8700 Series routers, you can install:

Router

Power Supplies

Cisco 8711-32FH-M

Up to two 2KW AC or 2KW DC

Cisco 8712-MOD-M

Up to two 2KW AC or 2KW DC

Cisco 8711-48Z-M

Up to two 1.1KW AC or 1.2KW DC

Ensure that all power connection wiring conforms to the rules and regulations in the National Electrical Code (NEC) and in local codes.


Note


The Cisco 8700 Series routers doesn't support a mix of:

  • AC and DC Power Supply Units (PSUs).

  • Port-Side Intake (PSI) and Port-Side Exhaust (PSE) configurations.


Table 1. Power Supply Details for Cisco 8711-32FH-M and Cisco 8712-MOD-M Router

Module Type

PIDs

Description

Nominal Range

AC Power

PSU2KW-ACPI

PSU2KW-ACPE

single feed with 2KW capacity at 12V

100—127V AC, 12A, 50/60Hz and 200—240V AC, 10A, 50/60Hz.

DC Power

PSU2KW-DCPI

PSU2KW-DCPE

dual feed with 2KW capacity at any specified input voltage.

-48—60V DC, 55A

Table 2. Power Supply Details for Cisco 8711-48Z-M Router

Module Type

PIDs

Description

Nominal Range

AC Power

PSU1100W-ACPI

PSU1100W-ACPE

single feed with 1.1KW capacity at 12V

100—240V AC, 12—10A, 50/60Hz

DC Power

PSU1.2KW-DCPI

PSU1.2KW-DCPE

dual feed with 1.2KW capacity at any specified input voltage.

-48—60V DC, 34A

Power Connection Guidelines for AC-Powered Systems

When connecting AC-input Power Supply Units (PSUs) to the site power source, observe the guidelines described here.


Warning


Statement 1028—More Than One Power Supply

This unit might have more than one power supply connection. To reduce risk of electric shock, remove all connections to de-energize the unit.


  • Ensure that the AC-input power supply module has a detachable power cord.

  • Each chassis power supply should have a separate, dedicated branch circuit.

    • North America

      • PSU-2KW-ACPI and PSU-2KW-ACPE —Power supply modules require a 20 A circuit.

    • International—Circuits should be sized according to local and national codes.

  • If you are using a 208 or 240 VAC power source in North America, note that such lines are considered hot and the circuit must be protected by a two-pole circuit breaker.


    Warning


    Statement 1005—Circuit Breaker

    This product relies on the building’s installation for short-circuit (overcurrent) protection. To reduce risk of electric shock or fire, ensure that the protective device is rated not greater than:


    • 20 A (North America) and 16 A (Europe) circuit breaker for an AC-input power supply module.


    Warning


    Statement 1022—Disconnect Device

    To reduce the risk of electric shock and fire, a readily accessible disconnect device must be incorporated in the fixed wiring.


  • The source AC outlet must be within 9.84 to 14 feet (3.0 to 4.293 meters) of the system - depending on the length of the power cord, and should be easily accessible.

  • The AC power receptacles used to plug in the chassis must be the grounding type. The grounding conductors that connect to the receptacles should connect to protective earth ground at the service equipment level.

Power Supply Unit Input and Output Ranges

Power Supply Restrictions and Considerations


Warning


Statement 1028—More Than One Power Supply

This unit might have more than one power supply connection. To reduce risk of electric shock, remove all connections to de-energize the unit.



Warning


Statement 1005—Circuit Breaker

This product relies on the building’s installation for short-circuit (overcurrent) protection. To reduce risk of electric shock or fire, ensure that the protective device is rated not greater than:


  • 20 A (North America) and 16 A (Europe) circuit breaker for an AC-input power supply module.

  • 55 A DC-rated circuit breaker for each input of a DC-input power supply module, for safety purposes - irrespective of whether the inputs are power from a single or separate DC sources.

  • Cisco 8711-48Z-M - 40 A DC-rated circuit breaker for each input of a DC-input power supply module, for safety purposes - irrespective of whether the inputs are power from a single or separate DC sources.


Warning


Statement 1022—Disconnect Device

To reduce the risk of electric shock and fire, a readily accessible disconnect device must be incorporated in the fixed wiring.



Warning


Statement 1090—Installation by a Skilled Person

Only a skilled person should be allowed to install, replace, or service this equipment. See statement 1089 for the definition of a skilled person.



Warning


Statement 1091—Installation by an Instructed Person or Skilled Person

Only an instructed person or skilled person should be allowed to install, replace, or service this equipment. See statement 1089 for the definition of an instructed person or skilled person.



Warning


Statement 1073—No User-Serviceable Parts

There are no serviceable parts inside. To avoid risk of electric shock, do not open.



Warning


Statement 1099—Before Connecting to System Power Supply

High touch/leakage current—Permanently connected protective earth ground is essential before connecting to the system power supply.



Warning


Statement 1100—Before Making Telecommunication Network Connection

High touch/leakage current—Permanently connected protective earth ground is essential before connecting to the telecommunication network.


Observe the following guidelines and limitations:

  • Use one type of power supply in a router.

  • The power supply type that is used in the router depends on the type and configuration of the transceivers installed in it.

  • Do not install a mix of AC and DC power supplies in a router.

  • On Cisco 8712-MOD-M and Cisco 8711-32FH-M routers, power redundancy is not supported if either one or both power inputs are at 90V–140V AC.

  • The airflow direction must be the same for all power supply and fan modules in the router.

  • The AC-input power supplies support low-line voltage of 120V (Nominal) and high-line voltage of 220V (Nominal). If you need to change voltage type after installation, disconnect the feed from the power supply before switching the input voltage level.

Connect AC Power to the Chassis


Caution


The chassis relies on the protective devices in the building installation to protect against short circuit, overcurrent, and ground faults. Ensure that the protective devices comply with local and national electrical codes.

Note


We recommend that you occupy both the power supply slots of the fixed port routers with power supplies. In case a power module fails, it is recommended to retain the failed power module in its slot until it is replaced with a new power module. This recommendation ensures that the system airflow is not impacted adversely, which may then result in the overheating of the router and its components.

Warning


Statement 1017—Restricted Area

This unit is intended for installation in restricted access areas. Only skilled, instructed, or qualified personnel can access a restricted access area.



Warning


Statement 1003—DC Power Disconnection

To reduce risk of electric shock or personal injury, disconnect DC power before removing or replacing components or performing upgrades.



Warning


Statement 1046—Installing or Replacing the Unit

To reduce risk of electric shock, when installing or replacing the unit, the ground connection must always be made first and disconnected last.

If your unit has modules, secure them with the provided screws.



Warning


Statement 1022—Disconnect Device

To reduce the risk of electric shock and fire, a readily accessible disconnect device must be incorporated in the fixed wiring.


On Cisco 8711-32FH-M and Cisco 8712-MOD-M router, the following power supplies are supported:

  • PSU2KW-ACPI – 2000W AC, port-side intake airflow

  • PSU2KW-ACPE – 2000W AC, port-side exhaust airflow

On Cisco 8711-48Z-M router, the following power supplies are supported:

  • PSU1100W-ACPI - 1100W, port-side intake airflow

  • PSU1100W-ACPE - 1100W, port-side exhaust airflow


Important


Applicable only to Cisco 8711-32FH-M router:
  • System shall not operate at input voltage: 100-127VAC, 50/60Hz with a single AC power supply condition.

  • System shall operate at input voltage: 100-127VAC, 50/60Hz with dual AC power supply condition.



Note


A dual pole breaker is needed for installation. For determining the recommended breaker size, please adhere to local and national rules and regulations. The breaker size is based on the specifications of the product for the current drawn and the specified voltage level.

Procedure


Step 1

Verify that the AC cable is installed in the correct AC source and outlet type.

Step 2

Attach the AC power cable to the cable connector in the AC power module.

Step 3

Place the cable through the opening in the cable tie.

Step 4

Slide the cable tie toward the plug.

Step 5

Close the cable tie on the shoulder of the power cable to secure the power cable.

Figure 1. Connecting AC Power - Cisco 8711-32FH-M

1

AC power cable

2

Cable tie

Figure 2. Connecting AC Power - Cisco 8712-MOD-M

1

AC power cable

Figure 3. Connecting AC Power - Cisco 8711-48Z-M

1

AC power cable


Connect DC Power to the Chassis


Caution


The chassis relies on the protective devices in the building installation to protect against short circuit, overcurrent, and ground faults. Ensure that the protective devices comply with local and national electrical codes.



Note


We recommend that you occupy both the power supply slots of the fixed port routers with power supplies. In case a power module fails, it is recommended to retain the failed power module in its slot until it is replaced with a new power module. This recommendation ensures that the system airflow is not impacted adversely, which may then result in the overheating of the router and its components.

On Cisco 8711-32FH-M and Cisco 8712-MOD-M router, the following power supplies are supported:

  • PSU2KW-DCPI – 2000W AC, port-side intake airflow

  • PSU2KW-DCPE – 2000W AC, port-side exhaust airflow

On Cisco 8711-48Z-M router , the following power supplies are supported:

  • PSU1.2KW-DCPI

  • PSU1.2KW-DCPE

Procedure


Step 1

Verify that the correct fuse panel is installed in the top mounting space.

Step 2

Ensure that the DC circuit is powered down (either breaker turned off or fuse pulled) and proper lockout tag out procedures are followed. Use the cable (PID: PWR-2KW-DC-CBL) supplied with the power supply. You can purchase power supply cord separately from Cisco.

Note

 

For Cisco 8711-48Z-M router, the power supply cable is not supplied. You must use a DC PSU connector with Terminal Part No: RNB8-3.7 (or) Equivalent, and 8AWG wire cable.

Step 3

Dress the power according to local practice.

Step 4

Connect the office battery and return cables according to the fuse panel engineering specifications.

Step 5

Insert the DC connector into the DC receptacle on the power supply.

Figure 4. Connecting DC Power - Cisco 8711-32FH-M
Figure 5. Connecting DC Power - Cisco 8712-MOD-M

1

DC power cable

Figure 6. Connecting DC Power - Cisco 8711-48Z-M

Note

 

For Cisco 8711-48Z-M router, the power supply cable is not supplied. You must use a DC PSU connector with Terminal Part No: RNB8-3.7 (or) Equivalent, and 8AWG wire cable.

Figure 7. DC Power Cable - PWR-2KW-DC-CBL

Step 6

Ensure that the locking mechanism has engaged to secure the cable.

Step 7

Turn on the circuit breaker at the power source.


AC/DC-Input Power Cord Options

This table summarises the input and output power ranges for PSU high line applications on these routers:

  • Cisco 8711-32FH-M

  • Cisco 8712-MOD-M

  • Cisco 8711-48Z-M

AC-Input Power Cord Options for Cisco 8711-32FH-M, Cisco 8712-MOD-M, Cisco 8711-48Z-M Routers

Table 3. AC-Input Power Cord Options

Locale

Part Number

Length

Power Cord Rating

Australia, New Zealand

CAB-AC-10A-ANZ

14 ft (4.26 m)

10A, 250 VAC

Brazil

CAB-AC-10A-BRZ

14 ft (4.26 m)

10A, 250 VAC

Britain

CAB-AC-10A-GRB

14 ft (4.26 m)

10A, 250 VAC

China

CAB-AC-10A-CHN

14 ft (4.26 m)

10A, 250 VAC

Denmark

CAB-AC-10A-DEN

14 ft (4.26 m)

10A, 250 VAC

Europe

CAB-AC-10A-EU

14 ft (4.26 m)

10A, 250 VAC

Italy

CAB-AC-10A-ITA

14 ft (4.26 m)

10A, 250 VAC

Japan

CAB-AC-10A-JPN1

14 ft (4.26 m)

10A, 250 VAC

Japan

CAB-AC-10A-JPN2

14 ft (4.26 m)

10A, 250 VAC

Korea

CAB-AC-10A-KOR

14 ft (4.26 m)

10A, 250 VAC

North America

CAB-AC-10A-NA

14 ft (4.26 m)

13A, 125 VAC

Switzerland

CAB-AC-10A-CHE

14 ft (4.26 m)

10A, 250 VAC

India

CAB-IND-10A

8.2 ft (2.45 m)

10A, 250 VAC

Cabinet Jumper Power Cord (C14 to C15 Connectors) - All countries except Japan

CAB-C15-CBN

4 ft (1.22 m)

13A, 250 VAC

Cabinet Jumper Power Cord (C14 to C15 Connectors) - Japan

CAB-C15-CBN-JP

10 ft (3.05 m)

12 A, 250 VAC

Japan

CAB-C13-C14-2M-JP

2.3 ft (0.7 m)

10A, 250 VAC

India

CAB-C13-C14-3M-IN

4.6 ft (1.4 m)

10A, 250 VAC

Figure 8. CAB-AC-10A-NA

Note


For a 2KW DC PSU, use the cable (PID: PWR-2KW-DC-CBL) supplied with the power supply. You can purchase power supply cord separately from Cisco.


AC/DC-Input Power Cord Options for Cisco 8712-MOD-M Router

Table 4. 30A HVAC/HVDC Cables

Locale

Part Number

Cisco Part Number (CPN)

Power Cord Set Rating

Connector Part Number

Power Cord Illustration

AUSTRALIA/NEW ZEALAND

CAB-AC-32A-ANZ

37-101007-01

32A, 250VAC

Saf-D-Grid 3-5958P4 to Hubbell C332P6S Plug

Refer the figure in 30A Cable Illustrations

SWITZERLAND

CAB-AC-32A-CHE

37-101007-01

32A, 250VAC

Saf-D-Grid 3-5958P4 to Hubbell C332P6S Plug

Refer the figure in 30A Cable Illustrations

ITALY

CAB-AC-32A-ITA

37-101007-01

32A, 250VAC

Saf-D-Grid 3-5958P4 to Hubbell C332P6S Plug

Refer the figure in 30A Cable Illustrations

SOUTH AFRICA

CAB-AC-32A-ZAF

37-101007-01

32A, 250VAC

Saf-D-Grid 3-5958P4 to Hubbell C332P6S Plug

Refer the figure in 30A Cable Illustrations

BRAZIL

CAB-AC-32A-BRZ

37-101007-01

32A, 250VAC

Saf-D-Grid 3-5958P4 to Hubbell C332P6S Plug

Refer the figure in 30A Cable Illustrations

ISRAEL

CAB-AC-32A-ISR

37-101007-01

32A, 250VAC

Saf-D-Grid 3-5958P4 to Hubbell C332P6S Plug

Refer the figure in 30A Cable Illustrations

ARGENTINA

CAB-AC-32A-ARG

37-101007-01

32A, 250VAC

Saf-D-Grid 3-5958P4 to Hubbell C332P6S Plug

Refer the figure in 30A Cable Illustrations

INDIA

CAB-AC-32A-IND

37-101007-01

32A, 250VAC

Saf-D-Grid 3-5958P4 to Hubbell C332P6S Plug

Refer the figure in 30A Cable Illustrations

NORTH AMERICA

CAB-AC-30A-US1

37-101008-01

30A, 250VAC

Saf-D-Grid 3-5958P4 to VOLEX 174606

Refer the figure in 30A Cable Illustrations

NORTH AMERICA

CAB-AC-30A-US2

37-101009-01

30A, 250VAC

Saf-D-Grid 3-5958P4 to VOLEX 174606

Refer the figure in 30A Cable Illustrations

NORTH AMERICA

CAB-DC-30A-US1

37-101014-01

30A, 400VDC

Saf-D-Grid 3-5958P4 to Saf-D-Grid 3-5958P4

Refer the figure in 30A Cable Illustrations

NORTH AMERICA

CAB-DC-30A-US2

37-101016-01

30A, 400VDC

Saf-D-Grid 3-5958P4 to Saf-D-Grid 3-5958P4

Refer the figure in 30A Cable Illustrations

NORTH AMERICA

CAB-AC-30A-US3

37-101013-01

30A, 277VAC

Saf-D-Grid 3-5958P4 to HBL2631

Refer the figure in 30A Cable Illustrations

NORTH AMERICA

CAB-AC-30A-US4

37-101018-01

30A, 300VAC

Saf-D-Grid 3-5958P4 to Saf-D-Grid 3-6074P30

Refer the figure in 30A Cable Illustrations

IEC/EU

CAB-AC-32A-EU

37-101019-01

32A, 300VAC

Saf-D-Grid 3-5958P4 to Saf-D-Grid 3-6074P30

Refer the figure in 30A Cable Illustrations

IEC/EU

CAB-DC-32A-EU1

37-101015-01

32A, 400VDC

Saf-D-Grid 3-5958P4 to Saf-D-Grid 3-5958P4

Refer the figure in 30A Cable Illustrations

IEC/EU

CAB-DC-32A-EU2

37-101017-01

32A, 400VDC

Saf-D-Grid 3-5958P4 to Saf-D-Grid 3-5958P4

Refer the figure in 30A Cable Illustrations

CHINA

CAB-AC-32A-CHN

37-101010-01

32A, 250VAC

-

Refer the figure in 30A Cable Illustrations

KOREA

CAB-AC-32A-KOR

37-101012-01

32A, 250VAC

-

Refer the figure in 30A Cable Illustrations

30A HVAC/HVDC Cable Illustrations

Figure 9. CAB-AC-32A-ANZ, CAB-AC-32A-CHE, CAB-AC-32A-ITA, CAB-AC-32A-BRZ, CAB-AC-32A-ZAF, CAB-AC-32A-ISR, CAB-AC-32A-IND, CAB-AC-32A-ARG Power Cord and Plugs for Standard AC Power Supply
Figure 10. CAB-AC-30A-US1 Power Cord and Plugs for Standard AC Power Supply
Figure 11. CAB-AC-30A-US2 Power Cord and Plugs for Standard AC Power Supply
Figure 12. CAB-DC-30A-US1 Power Cord and Plugs for HVDC Power Supply
Figure 13. CAB-DC-30A-US2 Power Cord and Plugs for HVDC Power Supply
Figure 14. CAB-AC-30A-US3 Power Cord and Plugs for Standard AC Power Supply
Figure 15. CAB-AC-30A-US4 Power Cord and Plugs for Standard AC Power Supply
Figure 16. CAB-AC-32A-EU Power Cord and Plugs for Standard AC Power Supply
Figure 17. CAB-DC-32A-EU1 Power Cord and Plugs for HVDC Power Supply
Figure 18. CAB-DC-32A-EU2 Power Cord and Plugs for HVDC Power Supply
Figure 19. CAB-AC-32A-CHN Power Cord and Plugs for Standard AC Power Supply
Figure 20. CAB-AC-32A-KOR Power Cord and Plugs for Standard AC Power Supply