Enabling Q-in-Q Encapsulation on Specific Leaf Switch Interfaces Using the GUI

Want to summarize with AI?

Log in

Enables Q-in-Q encapsulation mode on leaf switch ports, PCs, or vPCs using the APIC GUI. This configuration allows for double-tagged traffic processing on specified interfaces.


Before you begin

The tenant, application profile, and the application EPG that will be mapped with an interface configured for Q-in-Q mode should be created.

Leaf switch ports, PCs, or vPCs are enabled for Q-in-Q encapsulation mode in the Interface tab of one of the following locations in the APIC GUI.

  • Fabric > Inventory > Topology

  • Fabric > Inventory > Pod

  • Fabric > Inventory > Pod > leaf-name

Configure vPCs on the Topology or Pod Interface tab.

Procedure

  1. On the menu bar, choose Fabric > Inventory and click Topology , Pod , or expand Pod and choose a leaf.

  2. On the Topology or Pod panel Interface tab.

  3. Click the Operation / Configuration toggle-button to display the configuration panel.

  4. Click + to add diagrams of leaf switches, choose one or more switches, and click Add Selected .

    On the leaf-name panel Interface tab, a diagram of the switch appears automatically, after you click the Operation / Configuration toggle-button.

  5. Click the interfaces to be enabled for Q-in-Q encapsulation mode.

  6. To configure a port, perform the following steps:

    1. Click L2 on the upper left.
    2. On the L2 tab, on the L2 QinQ State field, click Double Q Tag Port and click Submit .
  7. To configure a PC, perform the following steps:

    1. Click PC on the upper left.
    2. On the Physical Interface tab, enter the Policy Group Name .
    3. On the L2 tab, on the L2 QinQ State field, click Double Q Tag Port and click Submit .
  8. To configure a vPC, perform the following steps:

    1. On two leaf switch diagrams, click the interfaces for the two legs of the VPC.
    2. Click vPC .
    3. On the Physical Interface tab, enter the Logical Pair ID (The identifier for the auto-protection group. Each protection group has a unique ID. The ID is a range of 1 to 1000) and the Policy Group Name .
    4. On the L2 tab, on the L2 QinQ State field, click Double Q Tag Port and click Submit .