Cisco APIC Layer 2 Networking Configuration Guide, Release 6.2(x)

PDF

Cisco APIC Layer 2 Networking Configuration Guide, Release 6.2(x)

Deploy Fibre Channel ports

Want to summarize with AI?

Log in

Activates Fibre Channel server host ports and uplink ports within the application profile configuration. This procedure ensures proper connectivity and domain association for Fibre Channel traffic.


This procedure activates the Fibre Channel server host ports and uplink ports.

Before you begin

  • Configure Fibre Channel (FC) server host port profiles (F ports).

  • Configure FC uplink port profiles (NP or TNP ports).

  • Configure a leaf switch profile that includes two associated interface selector profiles — one for host ports and one for uplink ports.

Procedure

  1. Expand Tenants > Tenant name > Application Profiles .

    If the tenant does not exist, you must create a tenant.

  2. Right click Application Profiles , click Create Application Profile , and perform the following actions:

    1. In the Name field, enter a name for the application profile.
    2. Click Submit .
  3. Expand Tenants > Tenant name > Application Profiles > name > Application EPGs .

  4. Right click Application EPGs and click Create Application EPG .

  5. In the Create Application EPG dialog box, perform the following actions:

    1. In the Name field, enter a name for the application EPG.
    2. Configure the following settings:

      Field

      Setting

      Intra EPG Isolation

      Select Unenforced .

      Preferred Group Member

      Select Exclude .

      Flood on Encapsulation

      Select Disabled .

    3. From the Bridge Domain drop-down list, select Create Bridge Domain .
    4. In the Name field, enter a name for the bridge domain.
    5. For Type , select fc to specify a Fibre Channel bridge domain.
    6. From the VRF drop-down list, select Create VRF .
    7. In the Name field, enter a name for the VRF.
    8. Click Submit to return to the Create Bridge Domain dialog box.
    9. Click Next , then Next , then Finish to return to the Create Application EPG dialog box.
    10. Click Finish .
  6. Expand Tenants > Tenant name > Application Profiles > name > Application EPGs > name > Domains (VMs and Bare-Metals) .

  7. Right click Domains (VMs and Bare-Metals) and click Add Fibre Channel Domain Association , and perform the following actions:

    1. From the Fibre Channel Domain Profile drop-down list, select the Fibre Channel domain that you created when you configured your host ports.
    2. Click Submit .
  8. Expand Tenants > Tenant name > Application Profiles > name > Application EPGs > name > Fibre Channel (Paths) and perform the following actions:

    This step deploys the server host ports.

    1. Right click Fibre Channel (Paths) and click Deploy Fibre Channel .
    2. In the Path Type control, click Port .
    3. From the Node drop-down list, choose the leaf switch.
    4. From the Path drop-down list, choose the leaf switch port that is configured as a server host port.
    5. In the VSAN field, enter the port VSAN.
    6. In the VSAN Mode control, click Native .
    7. Verify that the Type is fcoe.
    8. (Optional) If you require a traffic map, use the Pinning Label drop-down list.
      Note

      If multiple uplink ports are available and you want this host port to always direct its FLOGI to a specific uplink, you can create a pinning profile (traffic map) to associate the host port to the uplink port. Otherwise, hosts are load-balanced among the available uplink ports.

    9. Click Submit .
    10. Repeat from Step a for each Fibre Channel host port.
  9. Expand Tenants > Tenant name > Application Profiles > name > Application EPGs > name > Fibre Channel (Paths) and perform the following actions:

    This step deploys the uplink port channel.

    1. Right click Fibre Channel (Paths) and click Deploy Fibre Channel .
    2. In the Path Type control, click Direct Port Channel .
    3. From the Path drop-down list, choose the uplink port channel.
    4. In the VSAN field, enter the port default VSAN.
    5. In the VSAN Mode control, click Native for a port VSAN or Regular for a trunk VSAN.
    6. Verify that the Type is fcoe.
    7. Click Submit .