Cisco APIC Layer 2 Networking Configuration Guide, Release 6.2(x)

PDF

Cisco APIC Layer 2 Networking Configuration Guide, Release 6.2(x)

Configure a native Fibre Channel port profile using the GUI

Want to summarize with AI?

Log in

Configures a set of native Fibre Channel F ports for connecting to Fibre Channel hosts using the Configure an Interface, PC, and vPC wizard.


This procedure configures a set of native Fibre Channel (FC) F ports for connecting to Fibre Channel hosts, such as servers.

To simplify the configuration, this procedure uses the Configure an Interface, PC, and vPC wizard.

Procedure

  1. On the APIC menu bar, navigate to Fabric > Access Policies > Quickstart and click Configure an interface, PC, and vPC .

  2. In the Configured Switch Interfaces toolbar, click + to create a switch profile. Perform the following actions:

    This switch profile configures your server host ports. Another switch profile configures your uplink ports.

    1. From the Switches drop-down list, choose your NPV leaf switch.

      This action automatically creates a leaf switch profile. You can accept or change the name of the leaf switch profile in the Switch Profile Name text box.

    2. Click the large green + on the ports drawing to open more interface settings.
    3. For Interface Type , select FC to specify Fibre Channel host interface ports (F ports).
    4. For Interfaces , enter a port range for the FC ports.

      Only one contiguous range of ports can be converted to FC ports. This range must be a multiple of 4 ending with a port number that is a multiple of 4 (for example, 1-4, 1-8, and 21-32 are valid ranges).

      This action creates an interface selector policy. You can accept or change the name of the policy in the Interface Selector Name text box.

      Note

      Port conversion from Ethernet to FC requires a reload of the switch. After the interface policy is applied, a notification alarm appears in the GUI, prompting you to reload the switch. During a switch reload, communication to the switch is interrupted, resulting in timeouts when trying to access the switch.

    5. From the Policy Group Name drop-down list, select Create FC Interface Policy Group .
    6. In the Create FC Interface Policy Group dialog box, type a name in the Name field.
    7. In the Fibre Channel Interface Policy drop-down list, select Create Fibre Channel Interface Policy .
    8. In the Create Fibre Channel Interface Policy dialog box, type a name in the Name field and configure the following settings:

      Field

      Setting

      Port Mode

      For host interfaces, select F .

      Trunk Mode

      For host interfaces, select trunk-off .

      Speed

      Select auto (default).

      Auto Max Speed

      Auto Max Speed configuration is applicable only when speed is auto .

      Auto Max Speed is to limit maximum speed when speed is in auto mode.

      Receive Buffer Credit

      Select 64 .

    9. Click Submit to save the Fibre Channel interface policy and return to the Create FC Interface Policy Group dialog box.
    10. From the Attached Entity Profile drop-down list, choose Create Attachable Access Entity Profile .

      The attachable entity profile option specifies the interfaces where the leaf access port policy is deployed.

    11. In the Name field, enter a name for the attachable entity policy.
    12. In the Domains (VMM, Physical, or External) To Be Associated To Interfaces toolbar, click + to add a domain profile.
    13. From the Domain Profile drop-down list, choose Create Fibre Channel Domain .
    14. In the Name field, enter a name for the Fibre Channel domain.
    15. From the VSAN Pool drop-down list, choose Create VSAN Pool .
    16. In the Name field, enter a name for the VSAN pool.
    17. In the Encap Blocks toolbar, click + to add a VSAN range.
    18. In the Create VSAN Ranges dialog box, enter From and To VSAN numbers.
    19. For Allocation Mode , select Static Allocation and click OK .
    20. In the Create VSAN Ranges dialog box, click Submit .
    21. In the Create Fibre Channel Domain dialog box, click Submit .
      Note

      In the Fibre Channel Domain, when using native FC ports instead of FCoE, it is not necessary to configure a VLAN pool or VSAN attributes.

    22. In the Create Attachable Access Entity Profile dialog box, click Update to select the Fibre Channel domain profile and click Submit .
    23. In the Create FC Policy Group dialog box, click Submit .
    24. In the Configure Interface, PC, and vPC dialog box, click Save to save this switch profile for your server host ports.
    Note

    Port conversion from Ethernet to FC requires a reload of the switch. After the interface policy is applied, a notification alarm appears in the GUI, prompting you to reload the switch. During a switch reload, communication to the switch is interrupted, resulting in timeouts when trying to access the switch.

    Note

    When you change a port profile on a switch, for example reconfigure an uplink as downlink and reload the switch, communication to the switch is interrupted until the switch gets its configuration from Cisco APIC.

    In Fabric > Access Policies > Switches > Leaf Switches > Profiles > name , the Fibre Channel port profile appears in the Associated Interface Selector Profiles list in the Leaf Profiles work pane.

What to do next

  • Configure a Fibre Channel uplink connection profile.

  • Deploy the server ports and uplink ports in a tenant to connect to a Fibre Channel core switch.