The 400G to 100G breakout feature is supported on the fabric ports of the following line card:

  • N9K-X9716D-GX with the QDD-4X100G-FR-S, QDD-4X100G-LR-S, or QDD-400G-SR4.2-BD transceiver

The 400G to 100G breakout feature is supported on the fabric ports of the following switches:

  • N9K-C9348D-GX2A

  • N9K-C9364D-GX2A

  • N9K-C9332D-GX2B

  • N9K-C93600CD-GX

  • N9K-C9316D-GX

  • N9K-C9408 (beginning in the 6.0(2) release)

  • Beginning with the 6.0(2) release, the QDD-400G-SR4.2-BD optic is supported on 400G ports. The peer node with the 100G speed must use QSFP-100G-SR1.2 optics.

  • Beginning with the 6.0(3) release, 400G-to-100G breakout using a QDD-4ZQ100 cable of any length is supported only with the following platforms: N9K-C9332D-GX2B, N9K-C9348D-GX2A, N9K-C9364D-GX2A, N9K-C9316D-GX, and N9K-C93600CD-GX leaf and spine switches, and the N9K-X9716D-GX line card.

  • The N9K-C9400-SW-GX2A switch supports 400G breakout with the N9K-X9400-8D line card expansion module and the peer 100G-PCC is supported with the N9K-X9400-8D and N9K-X9400-16W line card expansion modules.

  • QDD-4X100G-FR-S and QDD-4X100G-LR-S optics are supported on 400G ports. The peer node with the 100G speed can use the following optics: QSFP-100G-DR-S, QSFP-100G-FR-S, or QSFP-100G-LR-S.

Connect the ports with one of the following cables:

  • Cisco QDD-4ZQ100-CU (1M, 2M, 2.5M, and 3M) (beginning in the 6.0(3) release)

  • MPO to 4xLC breakout splitter cable with QDD-4X100G-FR-S or QDD-4X100G-LR-S and 4 x QSFP-100G-DR-S, 4 x QSFP-100G-FR-S, or 4 x QSFP-100G-LR-S on the ends

  • MPO to breakout splitter cable with QDD-400G-SR4.2-BD and 4 x QSFP-100G-SR1.2 on the ends.

Observe the following general guidelines and limitations:

  • Deleting the port profile policy on an already broken out port will clean up the breakout configuration and bring the port back up in the native direction upon switch reload.

  • To change a fabric port with a QDD-400G-SR4.2-BD optic from non-breakout to breakout, you must remove the transceiver, connect the breakout cable to the transceiver, then reinsert the transceiver.

  • GX2 switches support the following switch to switch connectivity: Spine switch-to-leaf switch, Leaf switch-to-spine switch, and Leaf switch-to-leaf switch (multi-tier).

  • GX line cards support spine switch to leaf switch connectivity.

  • Spine switch-to-spine switch breakout is not supported.

  • Spine switch to IPN or ISN breakout is only supported with the Auto Breakout and only with the following 100G and 400G optics.

    • QDD-4X100G-FR-S or QDD-4X100G-LR-S optic on the spine switch and the compatible 100G optics such as QSFP-100G-FR-S and DSFP-100G-LR-S on the IPN or ISN side.

    • QDD-400G-SR4.2-BD optic on the spine switch and the QSFP-100G-SR1.2 optic on the IPN or ISN side.

    • The link does not come up when a QDD-400G-SR4.2-BD optic is on both the sides.

  • In a Cisco ACI environment, the operational requirements for the QDD-400G-SR4.2-BD transceiver vary significantly depending on whether the interface is configured as a Fabric or Access port and the specific nature of the peer device.

  • If you downgrade to a release that does not support breakout for the given hardware and ports, the breakout ports will become not broken out and the links will be down.

  • If you remove an SFP transceiver from a switch, you must wait at least 15 seconds before re-adding the transceiver.