Explains how virtual port channels allow links physically connected to two different ACI leaf nodes to appear as a single port channel to third-party devices.
A virtual port channel (vPC) is a link aggregation technology that
-
allows links that are physically connected to two different Cisco Application Centric Infrastructure (ACI) leaf nodes to appear as a single port channel (PC) to a third device
-
consists of two Cisco ACI leaf switches designated as vPC peer switches, and
-
forms a system referred to as a vPC domain where one peer is primary and one is secondary.
Vpc implementation behavior
The following behavior is specific to the Cisco ACI vPC implementation:
-
No dedicated peer-link between the vPC peers. Instead, the fabric itself serves as the Multi-Chassis Trunking (MCT).
-
Peer reachability protocol: Cisco ACI uses the Zero Message Queue (ZMQ) instead of Cisco Fabric Services (CFS).
-
ZMQ is an open-source, high-performance messaging library that uses TCP as the transport.
-
This library is packaged as libzmq on the switch and linked into each application that needs to communicate with a vPC peer.
-
-
Peer reachability is not handled using a physical peer link. Instead, routing triggers are used to detect peer reachability.
-
The vPC manager registers with Unicast Routing Information Base (URIB) for peer route notifications.
-
When IS-IS discovers a route to the peer, URIB notifies the vPC manager, which in turn attempts to open a ZMQ socket with the peer.
-
When the peer route is withdrawn by IS-IS, the vPC manager is again notified by URIB, and the vPC manager brings down the MCT link.
-
-
When creating a vPC domain between two leaf switches, the following hardware model limitations apply:
-
Generation 1 switches are compatible only with other generation 1 switches. These switch models can be identified by the lack of "EX," "FX, "FX2," "GX," or later suffix at the end of the switch name. For example, N9K-9312TX.
-
Generation 2 and later switches can be mixed together in a vPC domain. These switch models can be identified by the "EX," "FX, "FX2," "GX," or later suffix at the end of the switch name. For example N9K-93108TC-EX or N9K-9348GC-FXP.
-
-
Examples of compatible vPC switch pairs:
-
N9K-C9312TX and N9K-C9312TX
-
N9K-C93108TC-EX and N9K-C9348GC-FXP
-
N9K-C93180TC-FX and N9K-C93180YC-FX
-
N9K-C93180YC-FX and N9K-C93180YC-FX
Examples of incompatible vPC switch pairs:
-
N9K-C9312TX and N9K-C93108TC-EX
-
N9K-C9312TX and N9K-C93180YC-FX
-
-
Port channels and virtual port channels can be configured with or without LACP.
If you configure a virtual port channel with LACP, LACP sets a port to the suspended state if it does not receive an LACP PDU from the peer. This can cause some servers to fail to boot up as they require LACP to bring up the port logically. You can tune the behavior to individual use by disabling LACP suspend individual. To do so, create a port channel policy in your vPC policy group, and after setting the mode to LACP active, remove Suspend Individual Port. Afterward, the ports in the vPC will stay active and continue to send LACP packets.
-
Adaptive load balancing (ALB), based on ARP negotiation, across virtual port channels is not supported in Cisco ACI.
-
The 25 gig port does not come up on its own and displays the vpc peerlink is down error, if one of the vPC links is not cabled correctly.