Lists the supported switches, configuration restrictions, guidelines, and breakout limitations for port profiles.
Uplink and downlink conversion is supported on Cisco Nexus 9000 series switches with names that end in EX or FX, and later (for example, N9K-C9348GC-FXP or N9K-C93240YC-FX2). A FEX connected to converted downlinks is also supported.
For information about the supported supported Cisco switches, see Port profile configuration summary.
When an uplink port is converted to a downlink port, it acquires the same capabilities as any other downlink port.
Restrictions
-
Fast Link Failover policies and port profiles are not supported on the same port. If port profile is enabled, Fast Link Failover cannot be enabled or vice versa.
-
The last 2 uplink ports of supported leaf switches cannot be converted to downlink ports (they are reserved for uplink connections).
-
Dynamic breakouts (both 100Gb and 40Gb) are supported on profiled QSFP ports on the N9K-C93180YC-FX switch. Breakout and port profile are supported together for conversion of uplink to downlink on ports 49-52. Breakout (both 10g-4x and 25g-4x options) is supported on downlink profiled ports.
-
The N9K-C9348GC-FXP does not support FEX.
-
Breakout is supported only on downlink ports, and not on fabric ports that are connected to other switches.
-
A Cisco ACI leaf switch cannot have more than 56 fabric links.
-
Reloading a switch after changing a switch's port profile configuration interrupts traffic through the data plane.
-
If a port profile is configured on any LEM type and you want to replace that LEM, the replacement LEM type must match the LEM type you removed.
Guidelines
In converting uplinks to downlinks and downlinks to uplinks, consider these guidelines.
|
Subject |
Guideline |
|---|---|
|
Port profile guidelines for N9K-X9400-8D |
These guidelines apply for this LEM:
|
|
Port profile guidelines for N9K-X9400-16W |
These guidelines apply for this LEM:
|
|
Port profile guidelines for N9K-X9400-22L |
The 6.1(2) release adds support for this LEM. These guidelines apply:
|
|
LEM Mismatch |
On the N9K-C9400-SUP-A, if you have an N9K-X9400-22L LEM with its port profile configured on ports 7-18 and you replace it with another LEM type, like the N9K-X9400-8D or N9K-X9400-16W, the 8D or 16W module will show module status: LEM type mismatch. The failure occurs because the port profile conversions do not match. For the 8D and 16W modules, the port profile conversion is ports 1-6 only. To recover the 8D or 16W LEMs from mismatch, remove the port-profile configurations present on all the ports on the previous LEM (i.e., the N9K-X9400-22L LEM). There should not be any port profile configuration. After this process, do a clean reload to recover the LEMs. |
|
Decommissioning nodes with port profiles |
If a decommissioned node has the Port Profile feature deployed on it, the port conversions are not removed even after decommissioning the node. It is necessary to manually delete the configurations after decommission, for the ports to return to the default state. To do this, log onto the switch, run the Beginning with 6.0(5), the port-profile setting persists across the reload when running the |
|
Maximum uplink port limit |
When the maximum uplink port limit is reached and ports 25 and 27 are converted from uplink to downlink and back to uplink on Cisco 93180LC-EX switches: On Cisco N9K-93180LC-EX switches, ports 25 and 27 are the original uplink ports. Using the port profile, if you convert port 25 and 27 to downlink ports, ports 29, 30, 31, and 32 are still available as four original uplink ports. Because of the threshold on the number of ports (which is maximum of 12 ports) that can be converted, you can convert 8 more downlink ports to uplink ports. For example, ports 1, 3, 5, 7, 9, 13, 15, 17 are converted to uplink ports and ports 29, 30, 31 and 32 are the 4 original uplink ports (the maximum uplink port limit on Cisco 93180LC-EX switches). When the switch is in this state and if the port profile configuration is deleted on ports 25 and 27, ports 25 and 27 are converted back to uplink ports, but there are already 12 uplink ports on the switch (as mentioned earlier). To accommodate ports 25 and 27 as uplink ports, 2 random ports from the port range 1, 3, 5, 7, 9, 13, 15, 17 are denied the uplink conversion and this situation cannot be controlled by the user. Therefore, it is mandatory to clear all the faults before reloading the leaf node to avoid any unexpected behavior regarding the port type. It should be noted that if a node is reloaded without clearing the port profile faults, especially when there is a fault related to limit-exceed, the port might not be in an expected operational state. |
|
Switch |
Releases |
Limitations |
|---|---|---|
|
N9K-C93180LC-EX |
Cisco APIC 3.1(1) and later |
|
|
N9K-C9336C-FX2-E |
Cisco APIC 5.2(4) and later |
|
|
N9K-C9336C-FX2 |
Cisco APIC 4.2(4) and later |
|
|
N9K-C9336C-FX2 |
Cisco APIC 3.2(1) up through, but not including, 4.2(4) |
|
|
N9K-C93180YC-FX |
Cisco APIC 3.2(1) and later |
|
|
N9K-C93240YC-FX2 |
Cisco APIC 4.0(1) and later |
Breakout is not supported on converted downlinks. |