Table 1. Environmental specifications
Description Specification

Temperature, operating

41 to 95°F (5 to 35°C)

Derate the maximum temperature by 1°C for every 1000 ft. (305 meters) of altitude above sea level.

Temperature, nonoperating (when the appliance is stored or transported)

–40 to 149°F (–40 to 65°C)

Humidity (RH), operating

10 to 90%, noncondensing at 82°F (28°C)

Humidity (RH), nonoperating (when the appliance is stored or transported)

5 to 93% at 82°F (28°C)

Altitude, operating

0 to 10,000 ft. (0 to 3,048 m)

Altitude, nonoperating (when the appliance is stored or transported)

0 to 40,000 ft. (0 to 12,192 m)

Sound power level, measure A-weighted per ISO7779 LwAd (Bels), operation at 73°F (23°C)

44 and 56-core appliance: 5.5

112-core appliance:

  • Minimum configuration: 7.08

  • Typical configuration: 7.67

  • Maximum configuration: 8.24

Sound pressure level, measure A-weighted per ISO7779 LpAm (dBA), Operation at 73°F (23°C)

44 and 56-core appliance: 40

112-core appliance:

  • Minimum configuration: 57.6

  • Typical configuration: 63.5

  • Maximum configuration: 70.5