- Overview
- Troubleshooting the Cisco Intercloud Fabric Installation and Initial Setup
- Troubleshooting the Cisco Intercloud Fabric Upgrade
- Troubleshooting the Cisco Intercloud Fabric Cloud Setup
- Troubleshooting VM Lifecycle Management
- Troubleshooting the Cisco Intercloud Fabric Components
- Obtaining Help from Cisco
- Additional Information
- Issues with the Cloud Setup
- Deleting the Intercloud Fabric Cloud Setup
- Issues with the Intercloud Fabric Link
- Issues Creating the Intercloud Fabric Link
- Issues with the Intercloud Fabric Link Status Operation
- Issues Updating the Intercloud Fabric Link
- Issues Starting the Intercloud Fabric Link
- Issues Stopping the Intercloud Fabric Link
- Issues Rebooting the Intercloud Fabric Link
- Issues Deleting the Intercloud Fabric Link
- Issues with the Intercloud Fabric Link Switchover Operation
Troubleshooting the
Cisco Intercloud Fabric Cloud Setup
- Issues with the Cloud Setup
- Deleting the Intercloud Fabric Cloud Setup
- Issues with the Intercloud Fabric Link
Issues with the Cloud Setup
This section includes symptoms, possible causes, and solutions for issues encountered while setting up an Intercloud Fabric cloud.
- Symptom: Creating an Intercloud Fabric cloud failed.
-
Possible Cause: The network does not have enough available IP addresses.
- Symptom: Resources required for this REST API operation are not available.
-
Possible Cause: Locks are not available for the required associated objects.
- Symptom: The REST API operation cannot be performed because the referenced object with OID {0} cannot be found.
-
Possible Cause: The referenced object may have been deleted by a concurrent operation running at approximately the same time and is no longer present.
- Symptom: Credentials validation failed.
-
Possible Cause: The cloud provider credentials were entered incorrectly.
- Symptom: From the VMware vCenter client, you cannot determine which VSM virtual machine (VM) configuration is active (primary) and which configuration is standby (secondary).
-
Possible Cause: While deploying the Intercloud Fabric Switch in high availability mode, you created the VMs with names similar to the Intercloud Fabric VSM high availability VM names.
- Symptom: Intercloud Fabric cloud creation fails with a message stating that SCP is not present on the VM.
-
Error Message:
Jan 23 2015 20:32:15 GMT Error occurred while Template Creation: ICFC Task State: Failed. Task Message: OS not compatible:scp not present on VM Jan 23, 2015 20:33:49 GMT Handler failed with error - ICFC Task State: failed. Task Message: OS not compatible:scp not present on VM, selectedContext=<None> Jan 23, 2015 20:33:49 GMT Task #1 (InterCloud Create Template (Create Template in Cloud)) failed after 456 seconds
- Symptom: Creating an Intercloud Fabric cloud fails with the error, "Failed to create instance".
-
Error Message:
Jan 23, 2015 07:28:08 GMT [Deploy IcSwitchInst : icldCiscoITDD3-iclink-ics-1] [Step 1 of 4 : Instantiate IcSwitch][Create instance failed for instance: Failed to create instance: 00050a12-fab0-43d6-005-a12fab043d6Error not populated][Retry Count:5] Jan 23, 2015 07:28:08 GMT (Deploy IcSwitchInst : icldCiscoITDD3-iclink-ics-1 failed: Create instance failed for instance: Failed to create instance: 00050a12-fab0-43d6-0005-0a12fab043d6Error not populated) Jan 23, 2015 07:28:08 GMT 'icldCiscoITDD3' is the last IcfCloud for Provider Account 'CiscoITDDwedd'.
- Symptom: After rebooting the host on which Intercloud Fabric, ICFC, Intercloud Fabric Extender, and Intercloud Fabric VSM are deployed and powering on all VMs, there is no communication between private VMs and cloud VMs.
-
Possible Cause: The Intercloud Fabric Extender host was rebooted out-of-band, resulting in a loss of communication and modules being unable to register with the Intercloud Fabric VSM.
- Symptom: The Intercloud Fabric cloud is deployed but the tunnel is not operational.
-
Possible Cause: The control channel port or data tunnel port is not open in the firewall.
- Symptom: Creating an Intercloud Fabric cloud in AWS fails.
-
Error Message:
Unable to create tempVM
- Symptom: Intercloud Fabric link creation fails during deployment.
-
Possible Cause: There are several causes for Intercloud Fabric link creation failure. Use the following steps to identify where the failure occurs.
- Symptom: Unable to allocate IP addresses.
-
Possible Cause: Intercloud Fabric cannot allocate the correct number of IP addresses for the ICX/ICS interfaces.
- Symptom: Port profile creation fails on cloud VSM (cVSM).
-
Possible Cause: There are varying causes for port profile creation failure.
- Symptom: Intercloud Fabric flow times out during the port profile operation.
-
Possible Cause: Port profile operations can time out for multiple reasons:
-
NTP configuration: ICFC cannot communicate with cVSM if the ICFC clock is set ahead of the cVSM clock.
-
REST connectivity to cVSM is not working.
-
cVSM service is down.
-
Port profile configuration errors.
-
- Symptom: ICFC rejects ICF port profile requests.
-
Possible Cause: There are varying causes for rejected ICF port profile requests.
- Symptom: An ICX VM creation on vCenter failure occurs during ICX deployment.
-
Possible Cause: ICFC cannot connect with vCenter, or the host or data store where ICFC is deploying the ICX VM is unreachable.
- Symptom: The Intercloud Fabric Switch (ICS) VM was created in ICFC, but ICX cannot register with ICFC.
-
Possible Cause: Communication issue between ICFC and ICX.
- Symptom: The ICS upload or register image fails.
-
Possible Cause: Image creation fails while uploading ICFC or registering the ICS image on the public cloud.
- Symptom: ICFC fails to generate SSH certificates and pushes them to ICS using ICS's public IP address.
-
Possible Cause: Either the ICS public IP address is not reachable or port 22 is not open on the cloud.
- Symptom: ICS and ICX are registered with ICFC, but the site-to-site tunnel is not operational.
-
Possible Cause: ICFC fails to push tunnel and device profiles to ICS to form a site-to-site tunnel.
- Symptom: Intercloud Fabric link redundancy (high availability) fails.
-
Possible Cause: Intercloud Fabric link redundancy is not available if one of the two pairs belonging to ICX or ICS, named primary pair (IcLink-1) and secondary pair (IcLink-2), is not established and in operation.
- Symptom: Both primary and secondary ICF link come up in Active state instead of one in Active and the other in Standby.
-
Possible Cause: A Network connectivity problem between primary and secondary ICXs in ICF link can cause this issue.
- Symptom: ICF link becomes partial_operational or not_operational after out-of-band (from provider portal) reboot operation, or a stop operation followed by a start operation, of ICS instance(s).
-
Possible Cause: An out-of-band reboot operation, or a stop operation followed by a start operation, can cause this issue.
Deleting the Intercloud Fabric Cloud Setup
Use this procedure to delete the Intercloud Fabric cloud setup.
Issues with the Intercloud Fabric Link
This section includes symptoms, possible causes, and solutions for issues encountered while setting up an Intercloud Fabric link.
- Issues Creating the Intercloud Fabric Link
- Issues with the Intercloud Fabric Link Status Operation
- Issues Updating the Intercloud Fabric Link
- Issues Starting the Intercloud Fabric Link
- Issues Stopping the Intercloud Fabric Link
- Issues Rebooting the Intercloud Fabric Link
- Issues Deleting the Intercloud Fabric Link
- Issues with the Intercloud Fabric Link Switchover Operation
Issues Creating the Intercloud Fabric Link
- Symptom: The network IP pool has insufficient number of IP addresses.
-
ICX mgmt IP address allocation failed. There are not enough IP addresses in IP pool {0}. Requested [{1}], Available [{2}]. ICS mgmt IP address allocation failed. There are not enough IP addresses in IP pool {0}. Requested [{1}], Available [{2}].Possible Cause: The standalone Intercloud Fabric link network must have at least two IP addresses and at least four IP addresses available for HA.
- Symptom: Configuring port profiles on cVSM fails.
-
Port profiles creation failed. <ICFC exception message> Polling timed out. Waited 600 seconds for creation of ICF link port profiles.Possible Cause:
-
Unable to communicate with ICFC, or any HTTP or REST client error, while communicating with ICFC.
-
The cVSM is down. Infrastructure status will show as not operational.
-
- Symptom: Configuring Intercloud Fabric cloud constructs fails.
-
Failed to create ICF cloud resources. <ICFC exception message> Error creating ICF cloud resources on ICFC. <ICFC exception message> The subscription policy limit for resource type 'Network Security Group count' was exceeded. The limit for resource type 'Network Security Group count' is {} per subscription, the current count is {}, and the requested increment is 1.
Possible Cause:
-
Unable to communicate with ICFC or any HTTP or REST client error while communicating with ICFC.
-
The security group or ACL limit was exceeded on the provider account.
-
- Symptom: For ICX, one or more deployment tasks failed on ICFC.
-

Note
There are multiple possible causes for this issue.Possible Cause: The host, or datastore, is not reachable or does not have enough resources. The curl error will be viewable in the SR log.
Failed to create/deploy ICX on vCenter.
Issues with the Intercloud Fabric Link Status Operation
The following Intercloud Fabric link status symptom has three different scenarios for possible cause and verification and solution.
- Symptom: Scenario 1: The Intercloud Fabric link status fails.
-
Some of IcfLink deployment tasks failed were not complete, exiting workflow ICF link deployment tasks failed Deploy IcExtenderInst : link3-icx-1 FAILED. ICX failed to register with ICFC. Deploy IcExtenderInst : link3-icx-2 FAILED. ICX failed to register with ICFC.
Possible Cause: The VLAN ID on the management port-profile for ICX and ICS is incorrectly configured.
- Symptom: Scenario 2: The Intercloud Fabric link status fails.
-
Enabling routing has failed:link4-ics-2::CreateRoutingServiceWorkflow::1 (SR oid XXXX-XXXX-XXXX-XXXX-XXXX) Enabling Routing Service failed with error: Routing Service failed to create since link link4 is not-operational Check SR bad-link4-ics-2::CreateRoutingServiceWorkflow::1 (SR oid XXXX-XXXX-XXXX-XXXX-XXXX) for more details.
Possible Cause:
-
The VLAN ID for management is missing in the enterprise trunk port-profile.
-
Intercloud Fabric module(s) will not register to cVSM.
-
- Symptom: Scenario 3: The Intercloud Fabric link status fails.
-
Deploy IcExtenderInst : link1-icx-1 FAILED. ICX failed to register with ICFC ICF link deployment tasks failed Some of IcfLink deployment tasks failed were not complete, exiting workflowPossible Cause: The network’s gateway cannot be reached.
Issues Updating the Intercloud Fabric Link
- Symptom: The Intercloud Fabric link update fails.
-
Failed to connect to ICFC service ICFC is not responding. Contact support for further assistance
Possible Cause: ICFC cannot be reached during the Intercloud Fabric link update operation.
- Symptom: The Intercloud Fabric link update fails due to insufficient IP addresses.
-
Allocation of IPs for ICX and ICS components of ICF link failed ICX mgmt IP address allocation failed.9048://There are not enough usable IP addresses available in the IP pool v36-p2 (OID:0856be64-4cfd-408d-82c0-2302f299916c). The IPs in the IP pool are all in use by ICF or other systems. Requested [1], Available [0].
Possible Cause: There are an insufficient number of IP addresses in the IP pool.
Issues Starting the Intercloud Fabric Link
- Symptom: The Intercloud Fabric link fails to start.
-
IcfLink operation start failed 672664192334953970113101849022577607556 FAILED. virtual machine does not exist
Possible Cause: The ICX has been terminated out of band on VMware vCenter. Review the VM (ICX) in VMware vCenter.
Issues Stopping the Intercloud Fabric Link
- Symptom: The Intercloud Fabric link fails to stop.
-
ICFC Error Message:VM Cycle property value validation failed. The lifecycle operation stop on ICS failed.Possible Cause: ICS is being terminated out of band. Check the instance on AWS.
Issues Rebooting the Intercloud Fabric Link
- Symptom: The HA Intercloud Fabric link reboot fails.
-
Contacting to reboot ICF link link2-sa Reboot IcSwitchInst :link2-sa-ics-1 FAILED. Reboot Server failed for instance: i-f08af96c request POST https://ec2.us-east-1.amazonaws.com/ HTTP/1.1 failed with code 400, error: AWSError{requestId='278abe93-9684-4d9e-a0c0-fb586f18ca71', requestToken='null', code='IncorrectState', message='Cannot reboot instance i-f08af96c that is currently in stopped state.', context='{Response=, Errors=}'}Possible Cause: The ICS instance is in the powered off state.
Issues Deleting the Intercloud Fabric Link
- Symptom: The Intercloud Fabric link fails to delete.
-
Failed to undeploy Routing Service from Icflink link1-ha (Failed to connect to ICFC service)
Possible Cause: ICFC service is down during the Intercloud Fabric link delete operation.
Issues with the Intercloud Fabric Link Switchover Operation
- Symptom: The HA Intercloud Fabric link fails to switchover.
-
Standby ICS is not found to perform switchover of IcLink The ICF link switchover failed. Standby ICS cannot be found and cannot perform the switchover of ICF link.
Possible Cause: The secondary Intercloud Fabric link is offline due to an issue on ICX and ICS and may have been powered off.
Feedback