- What is a Cisco cBR Series Converged Broadband Router
- Prepare to Install
- Installing the Cisco cBR Chassis
- Installing the Fan Module in Cisco cBR
- Installing the Power System in the Cisco cBR Chassis
- Installing the Supervisor in the Cisco cBR Chassis
- Installing the Interface and PIC Cards in the Cisco cBR Chassis
- Powering Up the Cisco cBR Chassis
- Monitoring the Cisco cBR Chassis
- Monitoring the Fan Module in Cisco cBR
- Monitoring the Power System in the Cisco cBR Chassis
- Monitoring the Supervisor in the Cisco cBR Chassis
- Monitoring the Interface Card in the Cisco cBR Chassis
- Maintaining the Cisco cBR Chassis
- Maintaining the Fan Module for Cisco cBR
- Maintaining the Power System in the Cisco cBR Chassis
- Maintaining the Supervisor in the Cisco cBR Chassis
- Maintaining the Interface and PIC Cards in the Cisco cBR Chassis
- Maintaining the PHY Modules in the Cisco cBR Chassis
- Maintaining the Air Filter in the Cisco cBR Chassis
- Online Insertion and Removal of Cards on the Cisco cBR
- Troubleshooting the Cisco cBR
Maintaining the
Power System in the Cisco cBR Chassis
- Removing the AC Power Connections from the Cisco cBR Chassis
- Removing the DC Power Connections from the Cisco cBR Chassis
- Removing the Power Module from the Cisco cBR Chassis
- Removing the FPEM from the Cisco cBR Chassis
- Removing the Power Cassette Module from the Cisco cBR Chassis
Removing the AC Power Connections from the Cisco cBR Chassis
![]() Warning | The chassis ground connection must always be made first and disconnected last. |
![]() Warning | Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030 |
Required Tools and Equipment
| Step 1 | Power down the AC FPEM using the power switch. | ||||
| Step 2 | Power down the AC circuit or power source to which the AC power cord is connected. | ||||
| Step 3 | Loosen the Phillips-head screw on the cable retaining bracket using a #2 Phillips screwdriver. | ||||
| Step 4 | Unplug the AC
power cord from the receptacle on the
AC FPEM.
![]()
| ||||
| Step 5 | Repeat Step 2 to Step 4 for each AC power connection. |
Removing the DC Power Connections from the Cisco cBR Chassis
![]() Warning | The terminal block covers are an integral part of the safety design of the product. Do not operate the unit without the covers installed. Statement 1077 |
![]() Warning | When you install the unit, the ground connection must always be made first and disconnected last. Statement 1046 |
![]() Warning | Before performing any of the following procedures, ensure that power is removed from the DC circuit. Statement 1003 |
![]() Warning | Only trained and qualified personnel should be allowed to install, replace, or service this equipment. Statement 1030 |
Required Tools and Equipment
| Step 1 | Power down the DC FPEM using the power switch. |
| Step 2 | Power down the circuit or power supply to which the positive and negative lead cables are connected. |
| Step 3 | Remove the terminal block cover on the terminal block, from which you need to disconnect power, by pushing down on the bottom tab then pivoting the bottom out. |
| Step 4 | Loosen the 1/4-20 terminal bolts using a torque wrench and 7/16" hex socket and remove them. Disconnect the positive lead cable. |
| Step 5 | Loosen the
1/4-20 terminal bolts using a torque wrench and 7/16" hex socket and remove
them. Disconnect the negative lead cable.
![]() |
| Step 6 | Repeat Step 2 and Step 5 to disconnect each terminal block connection. |
| Step 7 | Insert the 1/4-20 terminal bolts and secure them using a torque wrench and 7/16" hex socket with a torque of 45-50 in-lb (5.08-5.65 Nm). |
| Step 8 | Reinstall the terminal block covers by clipping them on the top edge of the terminal block housing and then rotating them down until they snap into place. |
Removing the Power Module from the Cisco cBR Chassis
-
Attach an ESD-preventive wrist strap to your wrist and connect the other end to the grounding lug connected to the chassis.
-
Be aware of the weight and size of the equipment. Handle it with care.
Restrictions
-
For the DC-powered Cisco cBR with N+1 redundancy, ensure that the chassis has at least five operational DC Power Modules for the chassis to be functional.
-
For the AC-powered Cisco cBR with N+1 redundancy, ensure that the chassis has at least four operational AC Power Modules for the chassis to be functional.
-
For the AC-powered Cisco cBR with 1+1 redundancy, ensure that the chassis has six operational AC Power Modules for the chassis to be functional.
Required Tools and Equipment
What to Do Next
-
Replace the Power Module (if required).
-
Position the front power entry bezel on the chassis. Insert and tighten the two screws using a 3/16" flat-blade torque screwdriver with a torque of 5-7 in-lb (0.56-0.79 Nm) to secure the bezel.
Removing the FPEM from the Cisco cBR Chassis
-
For an AC-powered Cisco cBR chassis, remove the AC power connections.
For an DC-powered Cisco cBR chassis, remove the DC power connections.
-
Attach an ESD-preventive wrist strap to your wrist and connect the other end to the grounding lug connected to the chassis.
-
If you are replacing the entire power system, remove the Power Cassette Module.
-
Be aware of the weight and size of the equipment. Handle it with care.
Required Tools and Equipment
What to Do Next
Replace the FPEM (if required).
Removing the Power Cassette Module from the Cisco cBR Chassis
Required Tools and Equipment
What to Do Next
-
Replace the Power Cassette Module (if required).
-
Position the front power entry bezel on the chassis. Insert and tighten the two screws using a 3/16" flat-blade torque screwdriver with a torque of 5-7 in-lb (0.56-0.79 Nm) to secure the bezel.







Feedback