Most common network problems can be
attributed to cable problems involving media, connectors, and patch
panels. These are Layer 1 issues, which cannot be overlooked. For
example, multimode and single-mode fiber cables are often used for
ATM, FDDI, Fast Ethernet, and
Gigabit Ethernet
.
When troubleshooting problems with fiber-optic cables, an important
consideration is asymmetric connectivity problems. An asymmetric
connectivity problem occurs when one side of a transmit/receive cable
pair fails, but the remaining cable continues to forward frames.
Asymmetric connectivity can impair spanning-tree loop avoidance. Many
things can also go wrong with copper UTP cables
.
For example, cable that is exposed to high-traffic areas can be
smashed, bent, or pulled out of the jack causing connectivity
problems.
When troubleshooting cabling from a
device or between devices, ask the following questions:
- Are the cables the correct type for
this installation? Category 3 is for 10BaseT only. Was a Category 3
cable installed instead of a Category 5 cable?
- Is the Category 5 cable installed
correctly?
- Is the cable a crossover or a
straight through? Which type should it be? Compare the RJ-45
connector wiring at both ends of the cable if unsure.
- Is there a broken wire at either end
of the cable? Cables that are installed too tightly or bundled
together tightly with a tie wrap may have broken wires in the
connector. Cables that are pulled through a plenum can have broken
wires and exhibit intermittent open-circuit conditions.
- Is the cable longer than the 100 m
(328 ft) specification? A time domain reflectometer (TDR) can
display the length of the cable, including all wiring closet
connections.
- Is the punchdown wiring correct? Are
there any missing, loose, or broken wires on the punchdown block
?
- Is the network adapter
card/interface port at the user end functioning properly?
- Is the device connected to the
correct port? Is the port active?
- Is a transceiver used to convert
media? Is it functioning properly?
One method that can be used to test
installed cabling is to replace the entire cable run with an external
cable. If there is a segment of tested Category 5 cable, run the cable
between the two devices to test connectivity. This test will eliminate
any uncertainties about plant cables or punchdown connections. This
can also be verified with a cable tester.
Hubs are still used in many LAN
environments. Ensure that they are operating properly by checking the
link/status light for the port as well as the unit status LEDs.
|