show inventory

To display the physical inventory information for the switch hardware, use the show inventory command.

show inventory [ fex chassis_ID ]

Syntax Description

fex chassis_ID
(Optional) Specifies the Fabric Extender chassis ID. The chassis ID is from 100 to 199.

Command Default

Displays all hardware inventory information.

Command Modes

EXEC mode

Command History

Release
Modification
4.0(0)N1(1a)
This command was introduced.
4.0(1a)N2(1)
This command was modified to provide Fabric Extender support.

Examples

This example shows how to display the switch hardware inventory information:

switch# show inventory
NAME: "Chassis", DESCR: "Nexus5020 Chassis"
PID: N5K-C5020P-BF , VID: V04 , SN: SSI13390FZT
 
NAME: "Module 1", DESCR: "40x10GE/Supervisor"
PID: N5K-C5020P-BF , VID: V04 , SN: JAF1344BHNK
 
NAME: "Module 2", DESCR: "6x10GE Ethernet Module"
PID: N5K-M1600 , VID: V01 , SN: JAB1228018M
 
NAME: "Module 3", DESCR: "8x1/2/4G FC Module"
PID: N5K-M1008 , VID: V01 , SN: JAB1231020C
 
NAME: "Fan 1", DESCR: "Chassis fan module"
PID: N5K-C5020-FAN , VID: N/A , SN: N/A
 
NAME: "Fan 3", DESCR: "Chassis fan module"
PID: N5K-C5020-FAN , VID: N/A , SN: N/A
 
NAME: "Fan 4", DESCR: "Chassis fan module"
PID: N5K-C5020-FAN , VID: N/A , SN: N/A
 
NAME: "Fan 5", DESCR: "Chassis fan module"
PID: N5K-C5020-FAN , VID: N/A , SN: N/A
 
NAME: "Power supply 1", DESCR: "AC power supply"
PID: N5K-PAC-1200W , VID: V01 , SN: DTM134200L5
 
NAME: "Power supply 2", DESCR: "AC power supply"
PID: N5K-PAC-1200W , VID: V01 , SN: DTM134200L4
 
NAME: "FEX 100 CHASSIS", DESCR: "N2K-C2148T-1GE CHASSIS"
PID: N2K-C2148T-1GE , VID: V01 , SN: FOX1252GQJR
 
NAME: "FEX 100 Module 1", DESCR: "Fabric Extender Module: 48x1GE, 4X10GE Supervi
sor"
PID: N2K-C2148T-1GE , VID: V01 , SN: JAF1302ABDP
 
NAME: "FEX 100 Fan 1", DESCR: "Fabric Extender Fan module"
PID: N2K-C2148-FAN , VID: N/A , SN: N/A
 
NAME: "FEX 100 Power Supply 1", DESCR: "Fabric Extender AC power supply"
PID: N2K-PAC-200W , VID: V01 , SN: PAC12493LQX
 
NAME: "FEX 100 Power Supply 2", DESCR: "Fabric Extender AC power supply"
--More--
switch#
 

This example shows how to display the hardware inventory information for an attached Fabric Extender:

switch# show inventory fex 101
NAME: "FEX 100 CHASSIS", DESCR: "N2K-C2148T-1GE CHASSIS"
PID: N2K-C2148T-1GE , VID: V01 , SN: FOX1252GQJR
 
NAME: "FEX 100 Module 1", DESCR: "Fabric Extender Module: 48x1GE, 4X10GE Supervi
sor"
PID: N2K-C2148T-1GE , VID: V01 , SN: JAF1302ABDP
 
NAME: "FEX 100 Fan 1", DESCR: "Fabric Extender Fan module"
PID: N2K-C2148-FAN , VID: N/A , SN: N/A
 
NAME: "FEX 100 Power Supply 1", DESCR: "Fabric Extender AC power supply"
PID: N2K-PAC-200W , VID: V01 , SN: PAC12493LQX
 
NAME: "FEX 100 Power Supply 2", DESCR: "Fabric Extender AC power supply"
PID: N5K-PAC-200W , VID: 00V0, SN: PAC12423L1Q
 
switch#
 

Related Commands

Command
Description
show hardware internal
Displays information about the physical hardware.
show module
Displays information about the modules.