Cisco ONS 15454 2.5 Gbps Multirate Transponder Cards


µ¥ÀÌÅͽÃÆ®


Cisco ONS 15454 SONET/SDH ´ÙÁß ¼­ºñ½º Æ®·£½ºÆ÷Æ® Ç÷§ÆûÀ» À§ÇÑ 2.5-Gbps ¸ÖƼ·¹ÀÌÆ® Æ®·£½ºÆù´õ(Transponder) Ä«µå

2.5-Gbps ¸ÖƼ·¹ÀÌÆ® Æ®·£½ºÆù´õ Ä«µå¸¦ Áö¿øÇÏ´Â Cisco® ONS 15454 MSTP(Multiservice Transport Platform)Àº ´ëµµ½ÃÀÇ ¿£ÅÍÇÁ¶óÀÌÁî ¹× Áö¿ª SP»ç¾÷ÀÚ ³×Æ®¿öÅ©ÀÇ Enterprise Systems Connection(ESCON), ±¤ÄÉÀ̺í ä³Î, ±â°¡ºñÆ® ÀÌ´õ³Ý, SONET/SDH(ÃÖ´ë 2.5Gbps) ¹× ºñµð¿À ÀÎÅÍÆäÀ̽º¿Í ¼­ºñ½º¸¦ Æ÷ÇÔÇÑ ´Ù¾çÇÑ Á¾·ùÀÇ ¼­ºñ½º ÅëÇÕ°ú Àü¼ÛÀ» ´Ü¼øÈ­ÇÕ´Ï´Ù.

±×¸² 1
Cisco ONS 15454 SONET/SDH MSTP 2.5-Gbps ¸ÖƼ·¹ÀÌÆ® Æ®·£Æ®Æù´õ Ä«µå



¹è °æ

¸ÞÆ®·Î Æ®·£½ºÆ÷Æ® ³×Æ®¿öÅ©´Â Àú¼Ó DS-1/E-1, DS-3/E-3, 10/100BASE-T, OC-3/STM-1¿¡¼­ºÎÅÍ °í¼Ó OC-12/STM-4, ±â°¡ºñÆ® ÀÌ´õ³Ý, OC-48/STM-16 ¹× 10 ±â°¡ºñÆ® ÀÌ´õ³Ý ¼­ºñ½º¿¡ À̸£´Â ±¤¹üÀ§ÇÑ ¼­ºñ½º ¿ä±¸»çÇ×À» Áö¿øÇØ¾ß ÇÕ´Ï´Ù. ÃÖ±Ù SONET ADMs(add/drop multiplexers)´Â ÃÖ´ë OC-48/STM-16±îÁö µ¥ÀÌÅÍ ÅëÇÕ ¹× Àü¼ÛÀ» À§ÇÑ ¼­ºñ½º Ç÷§ÆûÀ» Á¦°øÇß½À´Ï´Ù. DWDM(dense wavelength-division multiplexing) Ç÷§ÆûÀº ±â°¡ºñÆ®,10±â°¡ºñÆ® ÀÌ´õ³Ý ¹× OC-3/STM-1¿¡¼­ OC-192/STM-64»çÀÌÀÇ ±¤ ½ÅÈ£µéÀ» À§ÇØ ¼³°èµÇ¾ú½À´Ï´Ù ÇÏÁö¸¸ ¾ÈŸ±õ°Ôµµ, ±¤¹üÀ§ÇÑ ¼­ºñ½º¸¦ Áö¿øÇϱâ À§ÇØ ¸ÞÆ®·Î DWDM°ú SONET ADMsÀ» Æ÷ÇÔÇÑ ´Ù¾çÇÑ Ç÷§Æû ŸÀÔÀ» ¼³Ä¡ÇÏ´Â °ÍÀº ´Ù¼öÀÇ SP »ç¾÷ÀÚ ¹× ¿£ÅÍÇÁ¶óÀÌÁî ³×Æ®¿öÅ©¿¡ ÅõÀÚºñ¿ë ¸é¿¡¼­ È¿°úÀûÀÌÁö ¾Ê½À´Ï´Ù. ±×·¯¹Ç·Î, ÅõÀÚºñ¿ë ¸é¿¡¼­ º¸´Ù È¿°úÀûÀÎ ³×Æ®¿öÅ· ¼Ö·ç¼ÇÀº Àú¼Ó DS-1/E-1¿¡¼­ °í¼Ó 10±â°¡ºñÆ® ÀÌ´õ³Ý ¹× OC-192/STM-64¿¡ À̸£±â±îÁö ¸ðµç ¼­ºñ½º¸¦ Á¦°øÇÒ ¼ö ÀÖ¾î¾ß ÇÕ´Ï´Ù.

Á¦Ç° °³¿ä


2.5-Gbps ¸ÖƼ·¹ÀÌÆ® Æ®·£½ºÆù´õ(2.5G Æ®·£½ºÆù´õ) Ä«µå(±×¸² 1)´Â ESCON, SONET OC-3¿¡¼­ OC-48±îÁö, SDH STM-1¿¡¼­ STM-16±îÁö, ±â°¡ºñÆ® ÀÌ´õ³Ý, 1-Gbps ¶Ç´Â 2-Gbps ±¤ÄÉÀ̺í ä³Î, ÇâÈÄ 64 ä³Î ¿î¿ëÀ» À§ÇÑ 50-GHz ÆÄÀåÀÇ ¾ÈÁ¤¼º, ITU ±ÔÁ¤¿¡ ºÎÇÕÇÏ´Â 100-GHzÀÌ»óÀÇ ÆÄÀå¿¡ ´ëÇÑ ±âŸ ¼­ºñ½ºµéÀ» Æ÷ÇÔÇؼ­155 Mbps ~ 2.48 Gbps¿¡ À̸£´Â ±¤¹üÀ§ÇÑ ¼­ºñ½º À¯ÇüµéÀ» Æ®·£½ºÆ÷Æ® ÇÒ ¼ö ÀÖ´Â ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù. 2.5G Æ®·£½ºÆù´õ Ä«µå ¾ÆÅ°ÅØó´Â Cisco ONS 15454 shelf cross-connect fabric¿¡ ¾×¼¼½ºÇÏÁö ¾Ê°íµµ ´ÜÀÏ È¸¼± DWDM ÀÎÅÍÆäÀ̽º¿¡ ¸ÅÇÎµÈ ´ÜÀÏ Å¬¶óÀ̾ðÆ® ÀÎÅÍÆäÀ̽º¸¦ Æ÷ÇÔÇÏ°í ÀÖ½À´Ï´Ù.

Ŭ¶óÀ̾ðÆ®¿¡ ´ëÇÑ ÀÎÅÍÆäÀ̽º´Â ±¤¹üÀ§ÇÑ SFP(Small Form-Factor Pluggable) ±¤ ¸ðµâÀ» ÅëÇؼ­ HDTV (high-definition television), D1/SDI video, DV6000, ¹× ´Ù¸¥ ±¤ÄÉÀ̺í ŸÀÔ(½Ì±Û ¹× ¸ÖƼ¸ðµå), ÆÄÀå(850 ¹× 1310 nm) ¹× ±¤¼¶À¯ µµ´Þ¹üÀ§(´Ü°Å¸®/»ç¹«½Ç ³»ºÎ, Á߰Ÿ®/´Ü°Å¸® µî)»Ó¸¸ ¾Æ´Ï¶ó ESCON, OC-3/STM-1, OC-12/STM-4, OC-48/STM-16, ±â°¡ºñÆ® ÀÌ´õ³Ý, 1-Gbps ±¤¼¶À¯ ä³Î/FICON, 2-Gbps ±¤¼¶À¯ ä³Î/FICONÀ» Æ÷ÇÔÇÑ ±¤¹üÀ§ÇÑ ¼­ºñ½º¸¦ °¡´ÉÇÏ°Ô ÇÕ´Ï´Ù. LC Ä¿³ØÅÍ¿Í ¿¬°áµÇ´Â SFP ±¤¸ðµâÀº °í¹ÐµµÀÇ Æ÷Æ® »ç¿ëÀ» °¡´ÉÇÏ°Ô ÇÕ´Ï´Ù.

DWDM ¶óÀÎ ÀÎÅÍÆäÀ̽º´Â LC Ä¿³ØÅ͸¦ ÀÌ¿ëÇÏ¿©, 50-GHz ÆÄÀåÀÇ ¾ÈÁ¤¼ºÀ» °¡Áø, ITU±ÔÁ¤¿¡ ºÎÇÕÇÏ°í, 100-GHz ´ëÀÇ ±¤ ÀÎÅÍÆäÀ̽ºÀÎ ´ÜÀÏ LR/LH(long-reach/Long-haul)À» Á¦°øÇÕ´Ï´Ù. ±×°ÍÀº OC-48¿Í G.709ÀÇ ¿À¹öÇìµå¸¦ ÇÕÇÑ °Í ÀÌ»óÀÇ ¶óÀÎ ¼Óµµ¿¡¼­±îÁö µ¿ÀÛ ÇÕ´Ï´Ù. DWDM output ¶óÀÎ ÀÎÅÍÆäÀ̽º´Â 100-GHz¿¡ ÀÎÁ¢ÇÑ 4°³ÀÇ ÆÄÀå¿¡ °ÉÃļ­ Á¶ÀýÇÒ ¼ö ÀÖ¾î 8°³ÀÇ °³º° Ä«µå À¯ÇüÀ» ÀÌ¿ëÇؼ­32-ä³Î DWDM ³×Æ®¿öÅ©¸¦ Áö¿øÇÒ ¼ö ÀÖ½À´Ï´Ù. 2.5GÀÇ °¢ Æ®·£½ºÆù´õ Ä«µå ÆÄÀåÀº º¸È£ ¹öÀüÀ̳ª ºñº¸È£ ¹öÀüÀ¸·Î Á¦°øµÇ¸ç, º¸È£ ¹öÀü¿¡´Â µÎ ¹ø° DWDM ¶óÀÎ Ãâ·Â/ÀÔ·ÂÀÌ Æ÷ÇԵǾî ÀÖ¾î DWDMÀ» ÅëÇÕ ¿ÉƼÄà ¶óÀÎ º¸È£°¡ °¡´ÉÇÕ´Ï´Ù. ÁõÆø ¹× ºÐ»ê º¸Á¤ÀÇ ÀåÁ¡À» ÀÌ¿ëÇÏ¿©, 2.5G Æ®·£½ºÆù´õ Ä«µå´Â ±¤ ½ÅÈ£ µµ´Þ°Å¸®¸¦ 500km ÀÌ»óÀ¸·Î ´Ã·ÁÁÖ´Â °ÍÀÌ °¡´ÉÇÕ´Ï´Ù. Á¦½ÃµÈ Á¦Ç°»ç¾ç ¹üÀ§ ³»¿¡¼­ FEC(forward error correction)¸¦ »ç¿ëÇÏ¿© µ¿ÀÛÇÒ ¶§, Ä«µå´Â BER(bite error rate)¿¡¼­ ÃÖ°í10E-15±îÁö Ŭ¶óÀ̾ðÆ® ÆäÀ̷ε带 Àü¼ÛÇÕ´Ï´Ù. (Ç¥ 1 ÂüÁ¶)

2.5G Æ®·£½ºÆù´õ Ä«µå´Â µ¿ÀÏÇÑ Ä«µå¿¡ Ŭ¶óÀ̾ðÆ®¿Í DWDM ¶óÀÎ ÀÎÅÍÆäÀ̽º ¸ðµÎ¸¦ Æ÷ÇÔÇÏ°í ÀÖ½À´Ï´Ù. 2.5G Æ®·£½ºÆù´õ Ä«µå´Â 12°³ ¸ÖƼ ¼­ºñ½º ÀÎÅÍÆäÀ̽º Ä«µå ½½·ÔÀ» °¡Áø Cisco ONS 15454 Ç÷§Æû¿¡, ±×¸®°í »óÈ£ ¿¬°á Ä«µå°¡ ÀÖ´Â ¶Ç´Â ¾ø´Â ½Ã½ºÅÛ¿¡µµ ÀåÂøÀÌ °¡´ÉÇÕ´Ï´Ù. ÀÛµ¿¿¡ ÇÊ¿äÇÑ À¯ÀÏÇÑ °ø¿ë Ä«µå À¯ÇüÀº ŸÀ̹Ö, Ä¿¹Â´ÏÄÉÀÌ¼Ç ¹× MSTP ½Ã½ºÅÛ ¹èÄ¡»óÀÇ ÄÁÆ®·Ñ Ä«µåÀÔ´Ï´Ù. ¸±¸®½º 4.6 ¼ÒÇÁÆ®¿þ¾î ¹öÀüºÎÅÍ Cisco ONS 15454 ½Ã½ºÅÛ¿¡ cross-connect Ä«µå¸¦ Ãß°¡Çϸé ÇÏÀ̺긮µå ¾ÖÇø®ÄÉÀ̼ÇÀÇ Áö¿øÀÌ °¡´ÉÇϸç, cross-connect Ä«µå¿¡¼­ ´Ù¸¥ Æ®·£½º Æ÷Æ®·Î 200-Mbps¿¡¼­ 2.5-Gbps±îÁöÀÇ µ¥ÀÌÅ͸¦ ÅëÇÕÇÒ ¼ö ÀÖ´Â °­·ÂÇÑ ¼º´ÉÀ» ±¸ÇöÇÕ´Ï´Ù.

2.5G Æ®·£½ºÆù´õ Ä«µå´Â ´ÙÀ½ ¼½¼Ç¿¡¼­ ¼³¸íµÇ´Â ÇÁ·ÎÅäÄÝ µ¶¸³¼º, ÆÄÀå µ¿Á¶¼º, À¯¿¬ÇÑ º¸È£ ¸ÞÄ¿´ÏÁò, Ç÷οì-¾²·ç ŸÀ̹Ö(flow-through timing), °ü¸® ¹× ¼º´É ¸ð´ÏÅ͸µ ±â´ÉÀ» Æ÷ÇÔÇÑ Æø³ÐÀº ¼­ºñ½º ±¸¼º¿¡ ÇÊ¿äÇÑ ´Ù¾çÇÑ Åë½Å »ç¾÷ÀÚ±Þ ±â´É ¹× °í±Þ ±â´ÉÀ» Áö¿øÇÕ´Ï´Ù.

ÇÁ·ÎÅäÄÝ µ¶¸³¼º


.2.5G Æ®·£½ºÆù´õ Ä«µå´Â 2R, 3R, 3R+ÀÇ ¼¼ °¡Áö µ¿ÀÛ ¸ðµå¸¦ ÅëÇØ Cisco ONS 15454 Ç÷§Æû¿¡¼­ transparent ÆÄÀå ¹× nontransparent ¼­ºñ½º ¸ðµÎ¸¦ Áö¿øÇÒ ¼ö ÀÖµµ·Ï ¼³°èµÇ¾ú½À´Ï´Ù. 2R ¸ðµå¿¡¼­ 2.5G Ä«µå´Â Ŭ¶óÀ̾ðÆ® ÀÎÅÍÆäÀ̽º¿Í DWDM ¶óÀÎ ÀÎÅÍÆäÀ̽º »çÀÌ¿¡¼­ µ¥ÀÌÅ͸¦ ¾ç¹æÇâÀ¸·Î Åõ¸íÇÏ°Ô Àü¼ÛÇÕ´Ï´Ù. µ¥ÀÌÅÍ´Â 155Mbps¿¡¼­ 2.5Gbps±îÁö ºñÆ® ¼Óµµ·Î º¯È­ÇÒ ¼ö ÀÖÀ¸¸ç, ESCON ¹× ºñµð¿À ½ÅÈ£(HDTV, D1, and C-Cor DV6000)¸¦ Æ÷ÇÔÇÕ´Ï´Ù. 2R ¸ðµå´Â Àιٿîµå ½ÅÈ£µéÀ» º¹¿øÇÏ°í ÀçÁõÆø½ÃÅ°Áö¸¸ ŸÀÌ¹Ö ÀçÁ¶Á¤(retiming)À» ÇÏÁö´Â ¾Ê½À´Ï´Ù.

. 3R ¸ðµå¿¡¼­ÀÇ2.5G Æ®·£½ºÆù´õ Ä«µå´Â Àιٿîµå ½ÅÈ£¸¦ Àç»ý½ÃÅ°°í, ÀçÁõÆø ¹× ŸÀÌ¹Ö ÀçÁ¶Á¤ÇÕ´Ï´Ù. Áö¿øµÇ´Â µ¥ÀÌÅÍ ºñÆ® ¼Óµµ´Â 155Mbps¿¡¼­ 2.499Gbps »çÀÌÀ̸ç, SONET/SDH OC-3/STM-1, OC-12/STM-4, OC-48/STM-16 ½ÅÈ£, 1- ±×¸®°í 2-Gbps ±¤ÄÉÀ̺í ä³Î ¹× FICON¿Í ±â°¡ºñÆ® ÀÌ´õ³ÝÀ» Æ÷ÇÔÇÕ´Ï´Ù.

3R °­È­ ¸ðµå¿¡¼­ 2.5Æ®·£½ºÆù´õ Ä«µå´Â ¾Õ¿¡¼­ ¼³¸íµÈ 3R ½ÅÈ£¿¡ ´ëÇÑ Åõ¸í ¼­ºñ½º Áö¿øÀ» À§ÇØ, FEC(forward error correction)±â´É°ú G709 À§¿¡ Ŭ¶óÀ̾ðÆ® ½ÅÈ£¸¦ ¸ÊÇÎ ÇÕ´Ï´Ù. G. 709 ±â¼úÀº ÆäÀ̷ε忡 ´ëÇÑ ¿£º§·ÎÇÁ(envelop)À» Á¦°øÇÏ°í ÀÎ-¼­ºñ½º(in-service) ¼º´É ¸ð´ÏÅ͸µ, º¸È£ ¹× ¿ÉƼÄà °ü¸® ±â´É(optical management function)À» °¡´ÉÄÉ ÇÏ´Â SONET/SDH¿Í °°Àº ·¹À̾ ±¸Á¶¸¦ Á¦°øÇÕ´Ï´Ù. ÀÌ·¯ÇÑ 3R+ ¸ðµå´Â ³×Æ®¿öÅ© ¼º´É ¹× ½Ã½ºÅÛÀÇ ÀÛµ¿¹üÀ§¸¦ ±Ùº»ÀûÀ¸·Î È®Àå½ÃÄÑÁÝ´Ï´Ù.

SONET-À̳ª SDH-±â¹ÝÀÇ Å¬¶óÀ̾ðÆ® ÆäÀ̷εåÀÇ °æ¿ì ¸ð´ÏÅ͸µ Àü¿ëÀÇ Åõ¸í ¸ðµå(¸ð´ÏÅ͸¸)¿Í ȸ¼± Á¾·á ¸ðµå, ÀÌ·¸°Ô 2°¡ÁöÀÇ ÀÛµ¿ ¸ðµå°¡ ÀÖ½À´Ï´Ù. ÀÌ Ä«µå´Â B1(BIP-8 ¼½¼Ç)°ú J0(¼½¼Ç ÃßÀû)°ú °°Àº ÁÖ¿ä SONET/SDH ¿À¹öÇìµå ¹ÙÀÌÆ®µéÀ» ¸ð´ÏÅ͸µÇÏ¿© ¼º´É ¸ð´ÏÅ͸µ»Ó ¾Æ´Ï¶ó ¿À·ùºÐ¸® ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù. Ãß°¡ÀûÀ¸·Î, Åõ¸í ¸ðµå¿¡¼­´Â ³×Æ®¿öÅ© ¹«°á¼ºÀ» º¸ÀåÇϱâ À§ÇØ ³×Æ®¿öÅ© ¸»´ÜÀÇ Å¬¶óÀ̾ðÆ® ÀÎÅÍÆäÀ̽º ½ÅÈ£ÀÇ ¼Õ½ÇÀ̳ª ÇÁ·¹ÀÓ ¼Õ½ÇÀº ¿¬°üµÇ¾î ÀÖ´Â °¡Àå ¿ø´Ü(far-end)ÀÇ Å¬¶óÀ̾ðÆ® ÀÎÅÍÆäÀ̽º·Î Àü¼ÛµÇ°í ·¹ÀÌÀú´Â Áߴܵ˴ϴÙ. ȸ¼± Á¾·á ¸ðµå¿¡¼­´Â Ŭ¶óÀ̾ðÆ® Àü¼Û ¿À¹öÇìµå(TOH)°¡ Á¾·áµÇ°í, B1/B2¹ÙÀÌÆ®µéÀº »ðÀÔµÈ ÀûÀýÇÑ ¿ø°Ý Ç¥½Ã ½ÅÈ£¸¦ ÅëÇØ Àç»ýµË´Ï´Ù.

ÆÄÀå µ¿Á¶¼º(Wavelength Tunability)


2.5G Æ®·£½ºÆù´õ Ä«µåµéÀº 50-GHz ÆÄÀåÀÇ ¾ÈÁ¤¼º°ú100-GHz ITU ±Ô°Ý »ó¿¡¼­ µ¿ÀÛÇϸç, Ä«µå´ç 100-GHz¿¡ ÀÎÁ¢ÇÑ 4°³ÀÇ Ã¤³Î¿¡ °ÉÃÄ Á¶ÀýÀÌ °¡´ÉÇϸç, 8°³ÀÇ °³º° Ä«µåµéÀº Àüü 32 ÆÄÀå Ç÷£À» ´Ù·ê ¼ö ÀÖ½À´Ï´Ù. º°µµÀÇ ¿ä±¸¸¦ À§ÇÑ ¸ðµç ÆÄÀåÀ» Ä¿¹ö ÇÒ ¼ö ÀÖ´Â 2.5G Æ®·£½ºÆù´õ Ä«µåÀÇ µ¿Á¶¼º ÅëÇÕ±â´ÉÀº °í°´ÀÇ inventory¸¦ ÇöÀúÈ÷ °¨¼Ò½Ãŵ´Ï´Ù.

À¯¿¬ÇÑ º¸È£ ¸ÞÄ¿´ÏÁò


Ç¥1¿¡¼­¿Í °°ÀÌ 2.5G Æ®·£½ºÆù´õ Ä«µå´Â Ŭ¶óÀ̾ðÆ®¿Í DWDM ¶óÀÎ ÀÎÅÍÆäÀ̽º ¸ðµÎ¿¡ ´ëÇÑ À¯¿¬ÇÑ º¸È£ ±â´ÉÀ» Á¦°øÇÏ¿© °í°´ ¾ÖÇø®ÄÉÀ̼ǿ¡¼­ ¿ä±¸µÇ´Â ´Ù¾çÇÑ SLA(service-level agreement)¸¦ Á¦°øÇÏ´Â µ¥ ÇÊ¿äÇÑ ±¤¹üÀ§ÇÑ ³×Æ®¿öÅ© ¼³Á¤À» Áö¿øÇÒ ¼ö ÀÖ½À´Ï´Ù.

Ç¥1 º¸È£ Çü½Ä
º¸È£¹æ½Ä ±â´É ±×¸²
ºñº¸È£ Ŭ¶óÀ̾ðÆ® ¹× DWDM ¶óÀÎ ÀÎÅÍÆäÀ̽º À̵é ÀÎÅÍÆäÀ̽º´Â ¾î¶°ÇÑ Å¬¶óÀ̾ðÆ® Å͹̳ΠÀÎÅÍÆäÀ̽º³ª Æ®·£½ºÆù´õ Ä«µå º¸È£µµ Á¦°øÇÏÁö ¾Ê½À´Ï´Ù. Ŭ¶óÀ̾ðÆ® ½ÅÈ£´Â ºñº¸È£ ´ÜÀÏ Æ®·£½ºÆù´õ Ä«µå¸¦ ÅëÇØ Æ®·£½ºÆ÷Æ® µË´Ï´Ù. ÀÌ¿Í °°Àº ¼³Á¤Àº Ŭ¶óÀ̾ðÆ® ÆäÀ̷ε带 UPSR/SNCP(unidirectional-path switched ring/ Subnetwork Connection Protection) ¶Ç´Â BLSR/MSP-SPR(Bidirectional Line Switch Ring/multiplex switching protection-shared protection ring) ÇÁ·ÎÅäÄÝÀ» ÅëÇØ º¸È£µÇ°í ÀÖ´Â DWDM ³×Æ®¿öÅ©·Î Àü¼ÛÇÏ´Â µ¥ ÀûÇÕÇÕ´Ï´Ù. ±×¸² 2
1+1 º¸È£ Ŭ¶óÀ̾ðÆ® ÀÎÅÍÆäÀ̽º À̵é ÀÎÅÍÆäÀ̽º´Â Æ®·£½ºÆù´õ Ä«µå»Ó ¾Æ´Ï¶ó Ŭ¶óÀ̾ðÆ® Å͹̳ΠÀÎÅÍÆäÀ̽º ¸ðµÎ¿¡ ´ëÇÑ º¸È£¸¦ Á¦°øÇÕ´Ï´Ù. 1+1 APS(Automatic Protection Switching)À» ÀÛµ¿ÇÏ´Â µÎ °³ÀÇ Å¬¶óÀ̾ðÆ® ÀÎÅÍÆäÀ̽º´Â Ŭ¶óÀ̾ðÆ® Å͹̳ΠÀåºñ ÀÎÅÍÆäÀ̽º »çÀÌ¿¡¼­ 󸮵Ǵ ½ºÀ§ÄªÀ» ÅëÇØ 2°³ÀÇ Æ®·£½ºÆù´õ Ä«µå¸¦ Åë°úÇÏ°Ô µË´Ï´Ù. ±×¸² 3
Y-ÄÉÀ̺í Ŭ¶óÀ̾ðÆ® ÀÎÅÍÆäÀ̽º ÀÌ ÀÎÅÍÆäÀ̽º´Â Ŭ¶óÀ̾ðÆ® Å͹̳ΠÀÎÅÍÆäÀ̽º º¸È£ ¾øÀÌ Æ®·£½ºÆù´õ Àåºñ ¹× DWDM Æ®·£½ºÆ÷Æ® º¸È£¸¦ Á¦°øÇÕ´Ï´Ù. ´ÜÀÏ Å¬¶óÀ̾ðÆ® ÀÎÅÍÆäÀ̽º´Â 2°³ÀÇ Æ®·£½ºÆù´õ Ä«µå·Î ³ª´²Áý´Ï´Ù. ÀÌ ±â´ÉÀº Æ®·£½ºÆù´õ Ä«µåÀÇ º¸È£ ¹öÀü¿¡¼­´Â Áö¿øµÇÁö ¾Ê½À´Ï´Ù. ±×¸² 4
º¸È£ DWDM ¶óÀÎ ÀÎÅÍÆäÀ̽º ÀÌ ÀÎÅÍÆäÀ̽º´Â 2.5G Æ®·£½ºÆù´õ Ä«µåÀÇ º¸È£µÈ ¹öÀüÀ» »ç¿ëÇÏ¿© ´ÜÀÏ Å¬¶óÀ̾ðÆ® ½ÅÈ£¸¦ À§ÇÑ ³×Æ®¿öÅ© º¸È£¸¦ Á¦°øÇÕ´Ï´Ù. ÀÌ Ä«µå´Â ¾Æ¿ô¹Ù¿îµå ½ÅÈ£¸¦ 2°³ÀÇ ÆÄÀå °æ·Î·Î ºÐ¸®ÇÕ´Ï´Ù. ½ÅÈ£ ¼ö½Å Ãø¸é¿¡¼­, Ä«µå¿¡¼­ 2°³ÀÇ ÀÔ·ÂµÈ ½ÅÈ£ Áß ´õ ³ªÀº ½ÅÈ£¸¦ ¼±ÅÃÇÏ¿© Ŭ¶óÀ̾ðÆ® ¼Û½Å±â·Î Àü¼ÛÇÕ´Ï´Ù. ±×¸² 5

±×¸² 2
ºñº¸È£ ¼³Á¤



±×¸² 3
1 + 1 ¼³Á¤



±×¸² 4
Y-º¸È£ ¼³Á¤



±×¸² 5
º¸È£µÈ DWDM ¶óÀÎ ¼³Á¤



Ç÷οì-¾²·ç ŸÀ̹Ö(Flow-Through Timing)

Æ®·£½ºÆù´õ Ä«µå´Â ŸÀÌ¹Ö ½ÅÈ£°¡ Ŭ¶óÀ̾ðÆ®·ÎºÎÅÍ DWDM ±¤ ÀÎÅÍÆäÀ̽º·Î "ÇÃ·Î¿ì ¾²·ç(Flow-Through)"ÇÏ°Ô ÇØÁÝ´Ï´Ù. ÇϳªÀÇ ÀÎÅÍÆäÀ̽º(Ŭ¶óÀ̾ðÆ® ¶Ç´Â ȸ¼±)·ÎºÎÅÍÀÇ º¹±¸µÈ ¼ö½Å±âÀÇ Å¸ÀÌ¹Ö ½ÅÈ£´Â ´Ù¸¥ ¼Û½Å±âÀÇ ÀÎÅÍÆäÀ̽º(ȸ¼± ¶Ç´Â Ŭ¶óÀ̾ðÆ®) ŸÀ̹ÖÀ» ¼³Á¤ÇÏ´Â µ¥ »ç¿ëµË´Ï´Ù. À̸¦ ÅëÇØ Æ®·£½ºÆ÷Æ® µÈ ½ÅÈ£°¡ ³ëµå ŸÀ̹Ö(node timing)À¸·ÎºÎÅÍ µ¶¸³µÈ »óÅ·ΠµÉ ¼ö ÀÖ½À´Ï´Ù.

°ü¸®(Management)


Cisco ONS 15454´Â Cisco Transport Manager EMS(element management system)ÀÇ Áö¿ø°ú ÇÔ²² ÅëÇÕµÈ Cisco Transport Controller Å©·¡ÇÁÆ® ÀÎÅÍÆäÀ̽º¸¦ ÅëÇÑ ¿î¿µ, °ü¸®, ¸ð´ÏÅ͸µ ¹× ÇÁ·ÎºñÀú´×(OAM&P) ±â´ÉÀ» Áö¿øÇÏ´Â ±¤¹üÀ§ÇÑ °ü¸® ±â´ÉÀ» Á¦°øÇÕ´Ï´Ù. 2.5G Æ®·£½ºÆù´õ Ä«µå´Â ¸ðµç 3R ¼­ºñ½º ÀÎÅÍÆäÀ̽º¿¡ ´ëÇØ ¼³Á¤ °¡´ÉÇÑ G.709 ±â´ÉÀ» Æ÷ÇÔÇÏ°í ÀÖ½À´Ï´Ù. G.709 ±â´ÉÀ» ÅëÇØ Åõ¸íÇÏ°Ô ¼­ºñ½º¸¦ Àü¼ÛÇÏ´Â Åë½Å »ç¾÷ÀÚ´Â Àü¼ÛµÈ ½ÅÈ£ ¼Õ½ÇÀ» À¯¹ßÇϰųª ¶Ç´Â SLA¿ä°ÇÀ» ÃÊ°úÇÏ°Ô µÇ´Â ³×Æ®¿öÅ©ÀÇ ¼Õ»óÀ» ½Äº°ÇÒ ¼ö ÀÖ½À´Ï´Ù. G.709ÀÇ GCC(General Communication Channel)Àº SONET/SDH ½ÅÈ£¿¡¼­ SDCC/RSDCC(section data communication channel/regenerator section data communications channel)¿Í ºñ±³ÇÑ ¹Ù¿Í °°ÀÌ Åõ¸íÇÏ°Ô Æ®·£½ºÆ÷Æ® µÈ ¼­ºñ½º ä³Îµé¿¡ ´ëÇØ °¢°¢ÀÇ ÆÄÀå ´ÜÀ§·Î °³º° Ä¿¹Â´ÏÄÉÀÌ¼Ç Ã¤³ÎÀ» Á¦°øÇÕ´Ï´Ù. ÀÌ·¯ÇÑ GCC´Â Cisco ONS 15454ÀÇ °í±Þ ³×Æ®¿öÅ© ÀÚµ¿ Ž»ö ±â´ÉÀ» DWDM-±â¹Ý ¼­ºñ½º±îÁö È®Àå½ÃÄÑ ÁÝ´Ï´Ù. SONET/SDH ¼­ºñ½ºÀÇ °æ¿ì, Á¾·á ¸ðµå°¡ ÀÛµ¿ ÁßÀÏ ¶§ SDCC¸¦ »ç¿ëÇϸé Cisco ONS 15454 SONET/SDH ³×Æ®¿öÅ© ¿ä¼Ò¿¡¼­ ºñ½ÁÇÑ ±â´ÉÀÌ °¡´ÉÇÏ¿© µ¿½Ã¿¡ SONET/SDH¿Í DWDM ³×Æ®¿öÅ©¸¦ °ü¸®ÇÒ ¼ö ÀÖ½À´Ï´Ù. ÅëÇÕµÈ Cisco ONS 15454 Cisco Transport Controller Å©·¡ÇÁÆ® ¸Å´ÏÀú»Ó¸¸ ¾Æ´Ï¶ó Ãß°¡ Cisco Transport Manager EMS´Â ½Ã½ºÅÛ OAM&P ±â´É¿¡ ´ëÇÑ »ç¿ëÀÚ ¾×¼¼½º¸¦ Á¦°øÇÕ´Ï´Ù.

¼º´É ¸ð´ÏÅ͸µ(Performance Monitoring)


2.5G Æ®·£½ºÆù´õ Ä«µåÀÇ ¼º´É ¸ð´ÏÅ͸µ ±â´ÉÀº Àü¼ÛµÇ´Â ¼­ºñ½º¿¡ µû¶ó ´Þ¶óÁý´Ï´Ù. 2R ¼­ºñ½ºÀÇ °æ¿ì, ¼º´É ¸ð´ÏÅ͸µÀº ¼ö½Å ¹× ¼Û½ÅµÇ´Â Àü·Â ¹× ·¹ÀÌÀú ¹ÙÀ̾ Àü·ù, ¸ñ·Ï ¹× DWDM ±¤ ÀÎÅÍÆäÀ̽º(¼ö½Å ¹× ¼Û½ÅµÇ´Â Àü¿ø, ·¹ÀÌÀú ¹ÙÀ̾ Àü·ù Æ÷ÇÔ)¸¦ Æ÷ÇÔÇÏ°í ÀÖ´Â SFP°¡ Á¦°øÇÏ´Â °Í¿¡ ÇÑÁ¤µË´Ï´Ù. 3R ¼­ºñ½ºÀÇ °æ¿ì, ¼º´É ¸ð´ÏÅ͸µÀº 2Gbps ±¤ÄÉÀ̺í ä³ÎÀ» Á¦¿ÜÇÑ À¯ÇüÀÇ ½ÅÈ£¿¡ µû¶ó È°¿ëÇÒ ¼ö Àִµ¥, ±×°ÍÀº ´Ù½Ã SFP ±¤ ¸ðµâ¿¡¼­ Àü¼ÛÇÑ ¼º´É ¸ð´ÏÅ͸µ Åë°è·Î ÇÑÁ¤µË´Ï´Ù.

SONET/SDH ½ÅÈ£ÀÇ °æ¿ì, ±¤¹üÀ§ÇÑ ¼º´É ¸ð´ÏÅ͸µ°ú ÀÓ°èÄ¡-ÃÊ°ú Á¶°Ç ¹× °æº¸µéÀº ITU G.783¹× ETS 300 417-1 Ç¥ÁØ »Ó ¾Æ´Ï¶ó °¢°¢ÀÇ Telcordia GR-474 ¿Í GR-2918¿¡ ÀÇÇØ Áö¿øµË´Ï´Ù. ±â°¡ºñÆ® ÀÌ´õ³Ý°ú 1-Gbps ±¤ÄÉÀ̺í ä³Î°ú °°Àº µ¥ÀÌÅÍ ¾ÖÇø®ÄÉÀ̼ÇÀÇ °æ¿ì, 8b/10b ¼º´É ¸ð´ÏÅ͸µÀÌ Áö¿øµË´Ï´Ù. ¸¶Áö¸·À¸·Î µðÁöÅÐ ·¦ÆÛ Ã¤³Î(digital wrapper channel)Àº °¢°¢ÀÇ ITU-T ¿ä°Çµé(G.709¿Í G.798)¿¡ ÀÇÇØ ¸ð´ÏÅ͸µ µË´Ï´Ù. ·¹ÀÌÀú ¹ÙÀ̾ Àü·ù ¹× ¼ö½Å±â ¿ÉƼÄà Àü·ÂÀ» Æ÷ÇÔÇÑ ¿ÉƼÄà ¼º´É ÆĶó¹ÌÅÍ°¡ Áö¿øµË´Ï´Ù. ¼º´É ¸ð´ÏÅ͸µ µ¥ÀÌÅÍÀÇ °è»ê ¹× ´©°è´Â 15ºÐ, 24½Ã°£ °£°ÝÀ¸·Î ÀÌ·ç¾îÁý´Ï´Ù.

2.5 Æ®·£½ºÆù´õ Ä«µå´Â Àü¸é¿¡ Ä«µåÀÇ ÀÛµ¿ »óÅ ½Äº°ÀÌ °¡´ÉÇÑ LED°¡ À־ À°¾ÈÀ¸·Î ½Å¼ÓÇÏ°Ô »óŸ¦ Á¡°ËÇÒ ¼ö ÀÖ½À´Ï´Ù. Àü¸é ÆÇ¿¡ ÀμâµÈ ÁÖȲ»ö ¿ø¸ð¾çÀÇ ¾ÆÀÌÄÜÀº ¹°¸®ÀûÀ¸·Î Ä«µå°¡ ¼³Ä¡µÉ ¼ö ÀÖ´Â ½©ÇÁ ½½·ÔÀ» ³ªÅ¸³À´Ï´Ù.

¾ÖÇø®ÄÉÀÌ¼Ç ¼³¸í


2.5G Æ®·£½ºÆù´õ Ä«µå´Â ±âÁ¸ÀÇ À¯¿¬ÇÑ Cisco ONS 15454 Ç÷§Æû¿¡ ¸¹Àº »õ·Î¿î ¾ÖÇø®ÄÉÀ̼ǵéÀ» Ãß°¡ÇÕ´Ï´Ù. ´ëÇ¥ÀûÀÎ ¾ÖÇø®ÄÉÀ̼ǿ¡´Â À¯»ç ½Ã ÁÖ µ¥ÀÌÅÍ ¼¾ÅÍ¿Í ¹é¾÷ µ¥ÀÌÅÍ ¼¾ÅÍ °£ÀÇ ¿¬°á¼ºÀ» Á¦°øÇÏ´Â SAN(storage-area networking) Æ®·£½ºÆ÷Æ®(±×¸² 6)°¡ ÀÖ½À´Ï´Ù.

±×¸² 6
Àç³­ º¹±¸ ¼¾ÅÍÀÇ SAN ¿¬°á



±×¸² 7¿¡ »ó¼¼ÇÏ°Ô ¼³¸íµÈ ´Ù¸¥ ¾ÖÇø®ÄÉÀ̼ÇÀº Åë½Å »ç¾÷ÀÚÀÇ Ä³¸®¾î ¼­ºñ½º ¾ÖÇø®ÄÉÀ̼ÇÀ» À§ÇÑ SONET/SDH ±â¹Ý ¼­ºñ½ºÀÇ Åõ¸í Æ®·£½ºÆ÷Æ®·Î½á OC-48/STM-16¸¦ ¿¹·Î µé ¼ö ÀÖ½À´Ï´Ù.

±×¸² 7
Åë½Å »ç¾÷ÀÚÀÇ Ä³¸®¾î ¼­ºñ½º¸¦ À§ÇÑ OC-192/STM-64 Æ®·£½ºÆ÷Æ®



°¢°¢ÀÇ ³×Æ®¿öÅ© ¾ÖÇø®ÄÉÀ̼ǵ鿡¼­ »ç¿ëÀÚ´Â DS-n/E-n Àü¿ë¼±, D1/SDI ¹× C-Cor DV6000 ºñµð¿À, ÀÌ´õ³Ý, ESCON, ±×¸®°í SONET/SDH OC-n/STM-mÀ» Æ÷ÇÔÇÑ Áö¿øµÇ´Â ±âŸ ÀÎÅÍÆäÀ̽º À¯ÇüÀ» È°¿ëÇÏ¿© µ¿ÀÏÇÑ Cisco ONS 15454 Ç÷§Æû¿¡¼­ ¼­ºñ½º À¯ÇüÀ» Á¶ÇÕÇÏ¿© Á¦°øÇÒ ¼ö ÀÖ½À´Ï´Ù.

½Ã½ºÄÚÀÇ ÀåÁ¡


Cisco ONS 15454 2.5G Æ®·£½ºÆù´õ Ä«µå´Â Cisco ONS 15454 Ç÷§ÆûÀÇ ¼­ºñ½º ´É·ÂÀ» º¸¿Ï ¹× È®Àå½ÃÄÑ ÁÝ´Ï´Ù. 2.5G Æ®·£½ºÆù´õ Ä«µå¸¦ »ç¿ëÇÏ¿© »ç¿ëÀÚµéÀº ¼­ºñ½º ÁýÇÕ(aggregation)À» Áö¿øÇÏ´Â ÀÔÁõµÈ Cisco ONS 15454 Ç÷§ÆûÀ» ÅëÇØ ÇöÀç º¸À¯ÇÏ°í ÀÖ´Â ±¤ÄÉÀ̺í Ç÷£Æ®¿¡ DS-1/E-1, DS-3/E-3, OC-n/STM-n, ¹× ÀÌ´õ³ÝÀ» Æ÷ÇÔÇÑ ÆÄÀå ¼­ºñ½º¸¦ Á¦°øÇÒ ¼ö ÀÖ½À´Ï´Ù. ±×¸² 8°ú 9¿¡¼­¿Í °°ÀÌ Cisco ONS 15454 Ç÷§ÆûÀ» ÅëÇØ »ç¿ëÀڴ ȥÇÕµÈ ¼­ºñ½º¸¦ Æ®·£½ºÆ÷Æ®Çϱâ À§ÇÑ µ¶¸³Çü ¸ÞÆ®·Î DWDM ¹× MSPP(Multiservice provisioning platforms) ¹èÄ¡ÀÇ Çʿ伺À» ÁÙÀÏ ¼ö ÀÖ½À´Ï´Ù.

±×¸² 8
ÇöÀçÀÇ DWDM ¾ÆÅ°ÅØó



±×¸² 9
Cisco ONS 15454 Hybrid DWDM ¾ÆÅ°ÅØó



Cisco ONS 15454 Optical Transport ¼Ö·ç¼ÇÀº ´ÙÀ½°ú °°ÀÌ ´Ù¾çÇÑ ¼³Ä¡ ¹× ±â´ÉÀ» Á¦°øÇÏ´Â ±âÁ¸ ³×Æ®¿öÅ© ¿ä¼Ò¿¡ ´ëÇÑ ¶Ù¾î³­ ÀÌÁ¡À» Á¦°øÇÕ´Ï´Ù. :
  • »õ·Î¿î ¼­ºñ½º ÀÎÅÍÆäÀ̽º ¼±Åà - Cisco ONS 15454 Ç÷§ÆûÀº ºñµ¿±â½Ä(DS-1/E-1, DS-3/E-3), SONET/SDH(EC-1, OC-3/STM-1 ¿¡¼­ OC-192/STM-64·Î), ÀÌ´õ³Ý(10, 100, 1000, 10,000 Mbps), SAN (ESCON, FICON, 1-Gbps°ú 2-Gbps ±¤ÄÉÀ̺í ä³Î), ºñµð¿À (D1 and C-Cor DV6000) ÀÎÅÍÆäÀ̽ºµéÀ» Æ÷ÇÔÇÑ ¼ÒÇÁÆ®¿þ¾î Ư¼º žÀç ¹æ½ÄÀ» ÀÌ¿ëÇÏ¿© ´ÜÀÏ ¼¨½Ã ¹æ½Ä¿¡¼­ È°¿ëÇÒ ¼ö ÀÖ´Â °¡Àå Æø³ÐÀº ¼­ºñ½º ÀÎÅÍÆäÀ̽ºµéÀ» Áö¿øÇÕ´Ï´Ù.
  • ´ÙÁß º¹±¸ ŸÀÔµé - Cisco ONS 15454 MSPP Ç÷§ÆûÀº 2°³³ª 4°³ÀÇ ±¤ÄÉÀ̺í BLSR/MS-SPR, UPSR/SNCP, linear APS/SNC ¹× PPMN(path-protected mesh networking)À» Áö¿øÇÕ´Ï´Ù. À̸¦ ÅëÇØ ¼­ºñ½º Á¦°ø¾÷ü´Â °Ç¹° ³×Æ®¿öÅ©¿¡ ´ëÇÑ ÄÝ·ºÅÍ ¶Ç´Â ±¤ÄÉÀ̺í»Ó ¾Æ´Ï¶ó, 2°³³ª 4°³ÀÇ ±¤ÄÉÀ̺í BLSR/MS-SPR º¹±¸¸¦ È°¿ëÇÏ¿© ÀϹÝÀûÀ¸·Î ¹èÄ¡µÈ »ç¹«½Ç °£ ³×Æ®¿öÅ©(inter-office network)¸¦ Æ÷ÇÔÇÑ Æ®·£½ºÆ÷Æ® ³×Æ®¿öÅ· ¾ÖÇø®ÄÉÀ̼ǵéÀÇ Àü ¿µ¿ª °ÉÃļ­ Ç÷§ÆûÀ» ¹èÄ¡ÇÒ ¼ö ÀÖ½À´Ï´Ù.
  • °ø¿ë ¶óÀÎ Ä«µå ¹× ¼¨½Ã - ¿ÉƼÄà ¶óÀÎ Ä«µåµéÀº º¹±¸ À¯Çü°ú ¹«°üÇÏ¿© ºñ¿ëÀý°¨ ¹× ±â¼úÀÚµéÀÌ °ü¸®Çϱ⿡ ¿ëÀÌÇÕ´Ï´Ù. ¶ÇÇÑ, ³×Æ®¿öÅ©°¡ º¯°æ°ú »ç¿ëÀÚ ÀÎÅÍÆäÀ̽ºÀÇ ¿ä±¸»çÇ×ÀÌ ´Þ¶óÁü¿¡ µû¶ó »ç¿ëÀÚ´Â ÇÊ¿äÇÑ ¸¸Å­ ½±°í °£´ÜÇÏ°Ô ¿ÉƼÄà ¼­Å¶ ÆÑÀ» Àç¹èÄ¡ÇÒ ¼ö ÀÖ½À´Ï´Ù.
  • °ø¿ë »õ½Ã À¯Çü - ¸ðµç ¿ÉƼÄà ÀÎÅÍÆäÀ̽º ¼Óµµ¸¦ Áö¿øÇÏ´Â °ø¿ë ¼¨½Ã´Â ±â¼úÀÚµéÀÌ ¿©·¯ ÀåºñµéÀÇ Ç÷§Æû¿¡ ´ëÇØ ±â¼ú ½Àµæ Çϴµ¥ »ç¿ëµÇ´Â ½Ã°£À» ´ë¿ªÆø°ú ¼­ºñ½º¸¦ ¿î¿µÇϴµ¥ È°¿ëÇÒ ¼ö ÀÖ°Ô ÇÕ´Ï´Ù. ¸¹Àº Àåºñ º¥´õµéÀº OC-3/STM-1, OC-12/STM-4µî°ú °°Àº ¿ÉƼÄà ȸ¼± ¼Óµµ Àü¿ë Ç÷§Æû°ú UPSR/SNCP, 2F-BLSR/MS-SPR, 4F-BLSR/MS-SPR µî°ú °°Àº º¹±¸ ¸ÞÄ¿´ÏÁò¿¡ µû¶ó ºÐ·ùµÈ Ç÷§ÆûµéÀ» Á¦°øÇÕ´Ï´Ù. ÀÌ´Â Á¦Ç° ÁÖ¹®½Ã È¥µ¿À» ¾ß±âÇÒ »Ó ¾Æ´Ï¶ó, ÇÊ¿äÇÑ Á¦Ç°ÀÌ ¿øÇÏ´Â ¾ÖÇø®ÄÉÀ̼ÇÀ» Áö¿øÇÒ ¼ö ÀÖ´ÂÁö Àǹ®ÀÌ »ý±æ ¼ö ÀÖ½À´Ï´Ù. Cisco ONS 15454ÀÇ È¸¼± ¼Óµµ, º¹±¸ À¯¿¬¼ºÀº ÁÖ¹® ¹× ¹èÄ¡¸¦ °£´ÜÇÏ°í, ½Å¼ÓÇÏ°Ô ±×¸®°í °£ÆíÇÏ°Ô ÇØÁÝ´Ï´Ù.
ÃÖ°íÀÇ ¸ÞÆ®·Î ±¤ Æ®·£½ºÆ÷Æ® Ç÷§ÆûÀÎ Cisco ONS 15454´Â °í¼º´É SONET/SDH Àü¼Û, ÅëÇÕ ±¤ ³×Æ®¿öÅ·, ÃÖ°íÀÇ ´ÙÁß ¼­ºñ½º ÀÎÅÍÆäÀ̽º ¹× °æÀï·Â ÀÖ´Â °æÁ¦ÀûÀÎ ÇýÅÃÀ» Á¦°øÇÕ´Ï´Ù.

Cisco ONS 15454 2.5-Gbps Multirate Transponder Card Ư¡ ¹× »ç¾ç

ÄÄÆÑÆ®ÇÑ µðÀÚÀÎ
  • DWDM ¿î¿ë¿¡ ´ëÇÑ ¾ç¹æÇâ Ŭ¶óÀ̾ðÆ®¸¦ Áö¿øÇÏ´Â ´ÜÀÏ ¼¨½Ã ½½·Ô µðÀÚÀÎÀÇ °í¹Ðµµ ¼Ö·ç¼Ç
  • ½©ÇÁ ¾î¼Àºí¸® ´ç ÃÖ´ë 12°³ÀÇ ¾ç¹æÇâ 2.5G Æ®·£½ºÆù´õ Ä«µå ÀåÂø, º£ÀÌ ÇÑ °³´ç 48°³ÀÇ Ä«µå
À¯¿¬ÇÑ º¸È£ ±â´É
  • UPSR/SNCP, BLSR/MSP, ¹× 1+1 APS/SNC¿¡ ´ëÇÑ Åõ¸í Áö¿ø
  • Y-ÄÉÀ̺í Ŭ¶óÀ̾ðÆ®
  • º¸È£µÈ DWDM ¶óÀÎ ¿É¼Ç
  • ºñº¸È£(0+1)
±ÔÁ¤ ÀûÇÕ¼º1
Áö¿øµÇ´Â ±¹°¡
  • SONET/ANSI ½Ã½ºÅÛ

  • ij³ª´Ù
  • ¿µ±¹
  • ¸ß½ÃÄÚ
  • Çѱ¹
  • ÀϺ»
  • À¯·´
  • À¯·´¿¬ÇÕ
  • È£ÁÖ
  • ´ºÁú·£µå
  • ½Ì°¡Æú
  • Áß±¹
  • ¸ß½ÃÄÚ
  • È«Äá
  • Çѱ¹
EMC (Class A)
  • ICES-003 Issue 3, 1997
  • GR-1089-ÄÚ¾î, Level 3
  • 47CFR15
  • EN 300 386-TC
  • CISPR22, CISPR24
  • EN55022, EN55024
¾ÈÀü¼º
  • CAN/CSA-C22.2 No.950-95, 3rd Edition
  • GR-1089-ÄÚ¾î
  • UL 60950
  • IEC 60950/EN60950, Third Edition
·¹ÀÌÀú
  • UL 60950
  • IEC60950/EN60950
  • IEC 60825-2 (2000)
  • CDRH (Ãëµæ ½ÂÀÎ ¹× º¸°í¼­)
  • IEC 60825-1 Am.2 (2001)
ȯ°æ
  • GR-63-ÄÚ¾î, Level 3
  • ETS 300-019-2-1 (½ºÅ丮Áö, Class 1.1)
  • ETS 300-019-2-2 (¿î¼Û, Class 2.3)
  • ETS 300-019-2-3 (¿î¿µÃø¸é, Class 3.1E)
¿ÉƼÄÃ
  • GR-253-ÄÚ¾î
  • G.691
  • G.709
  • G.975
Ç°Áú
  • 20³â°£ MTBF(mean time between failure) TR-NWT-000332, Issue 4, Method 1 °è»ê
±âŸ
  • AT&T NEDS (Network Equipment Development Standards) Generic ¿ä±¸»çÇ×, AT&T 802-900-260, Issue 3, December 1999
  • SBC TP76200MP, May 2003
  • Verizon SIT.NEBS.NPI.2002.010, October 2002
  • Worldcom ESD ¿ä±¸»çÇ×

Áö¿øµÇ´Â ±¹°¡
  • SONET/ANSI ½Ã½ºÅÛ

  • ij³ª´Ù
  • ¿µ±¹
  • ¸ß½ÃÄÚ
  • Çѱ¹
  • ÀϺ»
  • À¯·´
  • SDH/ETSI ½Ã½ºÅÛ2

  • À¯·´
  • È£ÁÖ
  • ´ºÁú·£µå
  • ½Ì°¡Æú
  • Áß±¹
  • ¸ß½ÃÄÚ
  • È«Äá
  • Çѱ¹
EMC ¹æÃâ(¹æ»ç¼±, ÀüÀÚÆÄ)
  • ICES-003
  • GR-1089-ÄÚ¾î
  • 47CFR15
  • VCCI V-3/2000.04
  • CISPR22
  • EN 300 386-TC
  • EN50081-1
  • EN55022
  • AS/NZS3548, Amendment 1 + 2 1995
EMC ¸é¿ª¼º
  • GR-1089-ÄÚ¾î
  • CISPR24
  • EN50082-2
  • EN300-386-TC
  • EN55024
¾ÈÀü¼º
  • CAN/CSA-C22.2 No. 60950-00 Third Ed., 12/1/2002
  • GR-1089-CORE
  • GR-63-CORE
  • TS001
  • UL 1950 Third Ed., 12/1/2000
  • EN60950 (to A4)
  • IEC60950/EN60950, Third Ed.
  • AS/NZS3260 Supplements 1,2,3,4, 1997
ȯ°æ
  • GR-63-ÄÚ¾î
  • AT&T NEDS (Network Equipment Design Specification)
  • ETS 300-019-2-1 (Class 1.1)
  • ETS 300-019-2-2 (Class 2.3)
  • ETS 300-019-2-3 (Class 3.1E)
±¸Á¶ ¿ªÇÐ
  • GR-63-CORE
  • AT&T NEDS
  • ETS 300-019 (Class 3.1E)
Àü¿ø ¹× Á¢Áö
  • SBC (TP76200MP)
  • ETS 300-132-1 (DC Àü¿ø)
  • ETS 300-253 (Á¢Áö)
¿ÉƼÄÃ
  • GR-253-ÄÚ¾î
  • G.691
  • LI> G.709
  • G.975
Ç°Áú
  • (MTBF) 20³â°£ MTBF(mean time between failure) TR-NWT-000332, Issue 4, Method 1 °è»ê
1 ¸ðµç ÀûÇÕ¼º Å×½ºÆ® ¹× ¹®¼­È­°¡ Á¦Ç°ÀÌ Ãâ½ÃµÉ ¶§°¡Áö ¿Ï·áµÇ´Â °ÍÀº ¾Æ´Õ´Ï´Ù. ij³ª´Ù, ¹Ì±¹, À¯·´À» Á¦¿ÜÇÑ ±¹°¡ÀÇ °í°´Àº ±¸¸ÅÇÑ °÷¿¡ ¹®ÀÇÇϽñ⠹ٶø´Ï´Ù.
2 ±âŸ ±¹°¡ÀÇ SDH/ETSI ¿ä°ÇÀÇ °æ¿ì ½Ã½ºÄÚ ¿µ¾÷ ´ã´çÀÚ¸¦ ÅëÇØ È®ÀÎÇϽñ⠹ٶø´Ï´Ù.

Ç¥ 3 ½Ã½ºÅÛ È£È¯¼º ¹× ¿ä°Ç
±¸¼º¿ä¼Ò Cisco ONS 15454 SONET/ANSI Cisco ONS 15454 SDH/ETSI
ÇÁ·Î¼¼¼­ TCC2 TCC2
»óÈ£ ¿¬°á
(Cross-connect)
¸ðµÎ °¡´É(4.5 ¹öÀüÀº Áö¿ø ¾ÈµÊ) ¸ðµÎ °¡´É(4.5 ¹öÀüÀº Áö¿ø ¾ÈµÊ)
½©ÇÁ ¾î¼Àºí¸® ¸ðµÎ °¡´É (4.5¹öÀüÀ» À§ÇÑ SA-ANSI) ¸ðµÎ °¡´É
½Ã½ºÅÛ ¼ÒÇÁÆ®¿þ¾î ¸±¸®½º 4.5.0 ¹öÀü ÀÌ»ó ¸±¸®½º 4.5.0 ¹öÀü ÀÌ»ó
½½·Ô ȣȯ¼º 1 ~ 6, 12 ~ 17 1 ~ 6, 12 ~ 17

Ç¥ 4 Á¦Ç° »ç¾ç
±â¼ú »ç¾ç Á¦Ç° »ç¾ç
Ŭ¶óÀ̾ðÆ® ÀÎÅÍÆäÀ̽º
ÀÔ·Â ºñÆ® ¼Óµµ
Áö¿øµÇ´Â ÀÎÅÍÆäÀ̽º(SFP(Small Form-Factor Pluggable) ±â¹Ý)
SONET/SDH
OC-3/STM-1
OC-12/STM-4
OC-48/STM-16
±â°¡ºñÆ® ÀÌ´õ³Ý
±¤ÄÉÀ̺í ä³Î/FICON, 1 Gbps and 2 Gbps
ESCON ºñµð¿À
D1 ºñµð¿À
C-Cor DV6000 2.5 Gbps
HDTV
1310 nm, ½Ì±Û ¸ðµå ±¤ÄÉÀ̺í (SMF), 15 km IR-1/S-1.1
1310 nm, SMF, 15 km IR-1/S-4.1
1310 nm, SMF, 15 km IR-1/S-16.1
850 nm, ¸ÖƼ ¸ðµå ±¤ÄÉÀ̺íMMF), 0.5 km, 1000BASE-SX
1310 nm, SMF, 10 km, 1000BASE-LX
850 nm, MMF, 0.3 km
1310 nm, SMF, 10 km
1310 nm, MMF, 2 km
1310 nm, SMF
1310 nm, SMF
1310 nm, SMF
ALS (Automatic laser shutdown) ¹× Àç½ÃÀÛ ITU-T G.664 (06/99)
Ä¿³ØÆ® ŸÀÔ (Tx/Rx) LC, µàÇ÷º½º
DWDM ¶óÀÎ ÀÎÅÍÆäÀ̽º
ºñÆ® ¼Óµµ Ãâ·Â 155 Mbps ¿¡¼­ 2.66 Gbps ±îÁö
ALS ¹× Àç½ÃÀÛ ITU-T G.664 (06/99)
ÆÄÀå, nominal, (¥ëTnom) 4 ä³Î Á¶À² °¡´É(Ç¥ 5)
½ºÆåÆ®·³ ¹üÀ§ (¥ëTmin ~ ¥ëTmax) 1530 ~1565 nm
½ºÆåÆ®·³ Æø@ 20 dB (¥Ä¥ë20) ¡¾0.025 nm
Ä¿³ØÅÍ Å¸ÀÔ(Tx/Rx) LC, µàÇ÷º½º
±¤ ¼Û½Å±â
À¯Çü
À¯Çü ´ÙÀÌ·ºÆ® ¸ðµâ·¹À̼Ç
Ãâ·Â(PTmin ~ PTmax)
ºñº¸È£ Ä«µå
º¸È£ Ä«µå
-1 ~ +1 dBm
-4.5 ~ -2.5 dBm
±¤¹Ý»ç ¼Õ½Ç ¿ä±¸»çÇ× (ÃÖ¼Ò) 20 dB
¼Ò±¤À²(ÃÖ¼Ò) (reminx) 8.2 dBm
·¹ÀÌÀú ¾ÈÀüµµ 1
±¤ ¼ö½Å±â
À¯Çü APD
°¨µµ, 3R ¸ðµå (PRmin ~ PRmax)
FEC off; BER = 10E-12; OSNR > 14 dB
FEC on; BER = 10E-15; OSNR > 14 dB
FEC off; BER = 10E-12; OSNR > 10 dB
FEC on; BER = 10E-15; OSNR > 6 dB
°¨µµ, 2R ¸ðµå (PRmin ~ PRmax)
BER = 10E-12; OSNR > 15 dB
-30 ~ -9 dBm
-31 ~ -9 dBm
-23 ~ -9 dBm
-25 ~ -9 dBm
-24 ~ -9 dBm
ÂüÁ¶: OSNR(Optical signal to noise ration)Àº 0.5-nm ´ë¿ªÆø¿¡¼­ Á¤ÀÇ.
Àü¼Û ÆгÎƼ
3R ¸ðµå - ºÐ»ê Àü·Â Æä³ÎƼ(FEC on or off)
3R ¸ðµå - ºÐ»ê OSNR Æä³ÎƼ(FEC on or off)
2R¸ðµå - ºÐ»ê Àü·Â Æä³ÎƼ3
2 dB @ ¡¾5400 ps
2 dB @ ¡¾5400 ps
3 dB @ ¡¾3300 ps
»ö ºÐ»ê Çã¿ë (DLRmax) ÃÖ´ë ¡¾5400 ps/nm (i ¸ðµå¿¡¼­ 360 km )
¼ö½Å Àåºñ ¹Ý»çÀ²(ÃÖ´ë) -27 dB
ÀÔ·Â ÆÄÀå ´ë¿ªÆø(_c_rx) Third window, ITU G.692, 1530-1565 nm
°ü¸®
Ä«µå LEDs
Àå¾Ö (FAIL)
ÀÛµ¿/´ë±â(ACT/STBY)
½ÅÈ£ Àå¾Ö(SF)
Ŭ¶óÀ̾ðÆ® Æ÷Æ® LEDS (2 »ö)
ÀÛµ¿ °æº¸ À¯/¹«
DWDM Æ÷Æ® LED (3 »ö)
ÀÛµ¿/´ë±â(º¸È£ Ä«µå ¸¸)/°æº¸
»¡°­»ö
³ì»ö/Ȳ»ö(Y-º¸È£)
Ȳ»ö
³ì»ö/»¡°­»ö
³ì»ö/Ȳ»ö/»¡°­»ö
Àü¿ø
Ç¥ÁØ
ÃÖ´ë
25 watts
35 watts
ÀÛµ¿ ȯ°æ
¿Âµµ -5 ~ 55¡ÆC
23 ~ 131¡ÆF
½Àµµ 5 ~ 95% ºñÀÀ°á
½ºÅ丮Áö ȯ°æ
¿Âµµ -40 ~185¡ÆF
40 ~85¡ÆC
½Àµµ 5 ~ 95% ºñÀÀ°á
3 2R ¸ðµå¿¡¼­ µµ´Þ ¹üÀ§´Â ÇÑ°è ºÐ»ê°ú ºñ±³ÇÑ °Íó·³ OSNR·Î Á¦Çѵ˴ϴÙ.

Ç¥ 5 2.5-Gbps ¸ÖƼ·¹ÀÌÆ® Æ®·£½ºÆù´õ Ä«µå4 ¿¡ ´ëÇÑ Áö¿ø ´ë¿ªÆø
Ä«µå (xx.x) ¥ë(nm) Ä«µå (xx.x) ¥ë(nm Ä«µå (xx.x) ¥ë(nm Ä«µå (xx.x) ¥ë(nm
30.3 1530.33
1531.12
1531.90
1532.68
38.1 1538.19
1538.98
1539.77
1540.56
46.1 1546.12
1546.92
1547.72
1548.51
54.1 1554.13
1554.94
1555.75
1556.55
34.2 1534.25
1535.04
1535.82
1536.61
42.1 1542.14
1542.94
1543.73
1544.53
50.1 1550.12
1550.92
1551.72
1552.52
58.1 1558.17
1558.98
1559.79
1560.61
34.2 1534.25
1535.04
42.1 1542.14
1542.94
50.1 1550.12
1550.92
58.1 1558.17
1558.98
35.8 1535.82
1536.61
43.7 1543.73
1544.53
51.7 1551.72
1552.52
59.7 1559.79
1560.61

4 ÆÄÀå ±â¹Ý ±¤ ¸ðµâ¿¡ ´ëÇÑ ¸®µå ŸÀÓÀº ½ÇÁ¦·Î ´Ù¾çÇÕ´Ï´Ù. ÆÄÀå ¼±ÅÃÀ» µ½±â À§ÇÏ¿©, ´ÙÀ½URLÀÇ ½Ã½ºÄÚ »çÀÌÆ® ÁÖ¹® ÆäÀÌÁö¿¡ ÀÖ´Â ½Ã½ºÄÚ °ßÀû¼­ ¶Ç´Â ¸®µåŸÀÓ ÅøÀ» ÂüÁ¶ÇϽʽÿÀ:
http://www.cisco.com/en/US/ordering/index.shtml

Ç¥ 6 ÁÖ¹® Á¤º¸5
Æ÷Æ® ¹øÈ£ ¼³¸í
15454-MR-L1-xx.x=
15454E-MR-1-xx.x=
100-Mbps~2.5-Gbps ¸ÖƼ·¹ÀÌÆ® Æ®·£½ºÆù´õ Ä«µå, ºñº¸È£ DWDM ¶óÀÎ, SFP Ŭ¶óÀ̾ðÆ® ¸ðµâ ½½·Ô, 100-GHz ITU DWDM ÆÄÀå, LC Ä¿³ØÅÍ
15454-MRP-L1-xx.x=
15454E-MRP-1-xx.x=
100-Mbps~2.5-Gbps ¸ÖƼ·¹ÀÌÆ® Æ®·£½ºÆù´õ Ä«µå, º¸È£ DWDM ¶óÀÎ, SFP Ŭ¶óÀ̾ðÆ® ¸ðµâ ½½·Ô, 100-GHz ITU DWDM ÆÄÀå, LC Ä¿³ØÅÍ
SFP ±¤ ¸ðµâ
15454-SFP3-1-IR=
15454E-SFP-L.1.1=
OC-3/STM-1/D1-SDI SFP, Áß/´Ü°Å¸® ¿ë, 1310 nm, ½Ì±Û ¸ðµå, LC Ä¿³ØÅÍ
15454-SFP12-4-IR=
15454E-SFP-L.4.1=
OC-12/STM-4 SFP, Áß/´Ü°Å¸® ¿ë, 1310 nm, ½Ì±Û ¸ðµå, LC Ä¿³ØÅÍ
15454-SFP-OC48-IR=
15454E-SFP-L.16.1=
OC-48/STM-16 SFP, Áß/´Ü°Å¸® ¿ë, 1550 nm, ½Ì±Û ¸ðµå, LC Ä¿³ØÅÍ
15454-SFP-200=
15454E-SFP-200=
ESCON SFP, ´Ü°Å¸®/»ç¹«½Ç³», 1310 nm, ¸ÖƼ ¸ðµå, LC Ä¿³ØÅÍ
15454-SFP-GE+-LX=
15454E-SFP-GE+-LX=
±â°¡ºñÆ® ÀÌ´õ³Ý, ±¤ÄÉÀ̺í ä³Î/FICON (1 and 2 Gbps) ¹× HDTV SFP, Àå°Å¸®, 1310 nm, ½Ì±Û ¸ðµå, LC Ä¿³ØÅÍ
15454-SFP-GEFC-SX=
15454E-SFP-GEFC-SX=
±â°¡ºñÆ® ÀÌ´õ³Ý, ±¤ÄÉÀ̺í ä³Î /FICON (1Gbps¿Í 2 Gbps) SFP, ´Ü°Å¸®/»ç¹«½Ç³», 850 nm, ¸ÖƼ¸ðµå, LC Ä¿³ØÅÍ
Y-º¸È£ ÀåÄ¡
15216-CS-SM-Y= Y-ÄÉÀÌºí ½ºÇø®ÅÍ/ÄĹÙÀÌ³Ê ¸ðµâ, ½Ì±Û ¸ðµå, ´ÜÀÏ-Æø ¸ðµâ, Cisco FlexLayer ½©ÇÁ ¾î¼Àºí¸®¿¡ ¼³Ä¡(15216-FL-SA)
15216-CS-MM-Y= Y-ÄÉÀÌºí ½ºÇø®ÅÍ/ÄĹÙÀÌ³Ê ¸ðµâ, ¸ÖƼ ¸ðµå, ´ÜÀÏ-Æø ¸ðµâ, Cisco FlexLayer ½©ÇÁ ¾î¼Àºí¸®¿¡ ¼³Ä¡(15216-FL-SA)
15216-FL-SA= ½©ÇÁ Á¶¸³Ç°, 4 ¸ðµâ ½½·Ô, ÇϳªÀÇ ·¢ ´ÜÀ§ ³ôÀÌ, Cisco FlexLayer Ç÷§Æû
5 ºÎÇ°¿¡ Ç¥½ÃµÈ "E"(ÀÌ°ÍÀº 15454E)´Â SDH ½Ã½ºÅÛ È£È¯¼ºÀ» ³ªÅ¸³À´Ï´Ù.

<¾÷µ¥ÀÌÆ®: 2004³â 6¿ù 5ÀÏ>

¸ÇÀ§·Î