Document ID: 12311
Contents
Introduction
Prerequisites
Requirements
Components Used
Conventions
Configurations
Logical View
IOCP
MVS/VTAM XCA Major Node: XCA770
VTAM Switched Major Node "SMNPU2"
VTAM LUGROUP Major Node: DDDLUMPX
Router Configuration for VM/VTAM
Verify
Troubleshoot
Related Information
Introduction
This configuration allows 253 TN3270 clients to access one application or monitor on one host.
Prerequisites
Requirements
There are no specific requirements for this document.
Components Used
This document is not restricted to specific software and hardware versions.
The information in this document was created from the devices in a specific lab environment. All of the devices used in this document started with a cleared (default) configuration. If your network is live, make sure that you understand the potential impact of any command.
Conventions
For more information on document conventions, refer to Cisco Technical Tips Conventions.
Configurations
In this section, you are presented with the information to configure the features described in this document.
Note: To find additional information on the commands used in this document, use the Command Lookup Tool (registered customers only) .
Logical View

The TN3270 clients connect to IP address 10.14.20.34 (port 23), and can be TN3270 or TN3270E clients. The TN3270 clients should not specify a static logical unit (LU) name, but should specify (as usual) a 3270 terminal-type to emulate.
On the host side, the single physical unit (PU) devoted to TN3270 traffic is CAPPU1. A static terminal LU called CAP01L01 is defined in the switched major node definition, DIRPU2. It inherits the LU characteristics defined in the PU definition. This LU can be used by an incoming TN3270E session that specifies CAP01L01 as its desired LU.
Two printers also are attached to the CAPPU1 PU: one type 1 and one type 3 (named CAP01L02 and CAP01L03, respectively). In these examples, these LUs are run and defined by the Remote Spooling Communications Software (RSCS) Virtual Media (VM) printing application.
The remainder of the LUs are defined dynamically and have the characteristics assigned to them by way of the DDDLU exit (ISTEXCSD) run against the DDDLUGMP LUGROUP.
IOCP
* * CHPID PATH=((18)),TYPE=CNC,PART=(MVS,REC) CNTLUNIT CUNUMBR=0770,PATH=(18),UNIT=SCTC,UNITADD=((70,16)) IODEVICE ADDRESS=(770,16),CUNUMBR=(0770),UNIT=SCTC *
MVS/VTAM XCA Major Node: XCA770
TSTP5BE VBUILD TYPE=XCA
PRTP5BE PORT DAPNO=0,CUADDR=770,SAPADDR=04,MEDIUM=RING,TIMER=60
*
* DIAL=YES on GROUP macro defines downstream PU2.0/PU2.1 devices
*
GRPP5BE GROUP ANSWER=ON, X
AUTOGEN=(100,L,P), X
CALL=INOUT, X
DIAL=YES, X
ISTATUS=ACTIVE
VTAM Switched Major Node "SMNPU2"
000001 SMNPU2 VBUILD TYPE=SWNET 000002 * 000003 CAPPU1 PU ADDR=02, C 000004 IDBLK=05D, C 000005 IDNUM=18101, C 000006 ISTATUS=ACTIVE, C 000007 LUGROUP=DDDLUGMP, C 000008 LUSEED=CAP01L##, C 000009 MAXPATH=1, C 000010 DLOGMOD=D4A32782,USSTAB=ISTINCDT, C 000011 MODETAB=ISTINCLM,SSCPFM=USS3270, C 000012 MAXDATA=2052,MAXOUT=2,PACING=7,VPACING=7,PUTYPE=2 000013 CAP01L01 LU LOCADDR=001 000014 CAP01L02 LU LOCADDR=002,MODETAB=RSCSTAB,DLOGMOD=RSCSPRT1, C 000015 LOGAPPL=APRSCS 000016 CAP01L03 LU LOCADDR=003,MODETAB=RSCSTAB,DLOGMOD=RSCSPRT3, C 000017 LOGAPPL=APRSCS
VTAM LUGROUP Major Node: DDDLUMPX
VBUILD TYPE=LUGROUP
DDDLUGMP LUGROUP
327904E LU DLOGMOD=SNX32704,LOGAPPL=VM, X
MODETAB=ISTINCLM,USSTAB=ISTINCDT, X
SSCPFM=USS3270
3279S4E LU DLOGMOD=SNX32704,LOGAPPL=VM, X
MODETAB=ISTINCLM,USSTAB=ISTINCDT, X
SSCPFM=USS3270
327804E LU DLOGMOD=LSX32704,LOGAPPL=VM, X
MODETAB=ISTINCLM,USSTAB=ISTINCDT, X
SSCPFM=USS3270
327804 LU DLOGMOD=D4A32782,LOGAPPL=ITPECHV, X
MODETAB=ISTINCLM,USSTAB=ISTINCDT, X
SSCPFM=USS3270
@ LU DLOGMOD=D4A32782,LOGAPPL=VM, X
MODETAB=ISTINCLM,USSTAB=ISTINCDT, X
SSCPFM=USS3270
Router Configuration for VM/VTAM
This TN3270 router configuration has the channel connection plugged into Port 1 of the Channel Interface Processor (CIP) card. The XCA770 adapter definition is attached to the CIP Internal Token Ring LAN #1. Adapter 0 is bound for the external communications adapter (XCA) in virtual telecommunications access method (VTAM), while Adapter 1 is bound for TN3270 on CIP. The TN3270 server is active, and has one PU (CAPPU1) trying to connect. The CIP also has reserved the 10.14.20.32 subnet for exclusive use by tasks running on the CIP card.
Router# write terminal Building configuration... .. .. interface Channel2/1 description CISCO Channel Interface Processor csna 0100 70 ! interface Channel2/2 description TN3270 Server ip address 10.14.20.33 255.255.255.248 no keepalive max-llc2-sessions 100 lan TokenRing 1 adapter 0 4000.0500.0001 !--- Bound to XCA in VTAM. adapter 1 4000.0501.0001 !--- Bound to TN3270 on CIP. tn3270-server maximum-lus 253 pu CAPPU1 05D18101 10.14.20.34 token-adap 1 44 rmac 4000.0500.0001 rsap 04 lu-seed CAP0IL##
Verify
There is currently no verification procedure available for this configuration.
Troubleshoot
There is currently no specific troubleshooting information available for this configuration.
Related Information
| Updated: Sep 09, 2005 | Document ID: 12311 |