Document ID: 12409
Contents
Introduction
Prerequisites
Requirements
Components Used
Conventions
Sniffer Trace
NetPro Discussion Forums - Featured Conversations
Related Information
Introduction
This document provides a summary sniffer trace for a Downstream Physical Unit (DSPU) to an upstream 3172.
Prerequisites
Requirements
There are no specific requirements for this document.
Components Used
This document is not restricted to specific software and hardware versions.
The information in this document was created from the devices in a specific lab environment. All of the devices used in this document started with a cleared (default) configuration. If your network is live, make sure that you understand the potential impact of any command.
Conventions
Refer to Cisco Technical Tips Conventions for more information on document conventions.
Sniffer Trace
This sniffer trace refers to a separate document that describes a sample configuration of a DSPU to an upstream 3172. Refer to Configuring DSPU to Upstream 3172 for more information.
Sniffer Network Analyzer data from 10-Feb-95 at 11:07:06, unsaved capture data,
Page 1
SUMMARY Delta T Destination Source Summary
M 1 400044000001 400044000001 LOOP Reply Receipt =46
2 0.242 NetBIOS IBM 9B7805 SMB C Transaction \MAILSLOT\LANMAN
3 2.679 Broadcast 400044000001 MAC Active Monitor Present
4 0.040 Broadcast IBM 9B7805 MAC Standby Monitor Present
5 0.000 Broadcast This Sniffer MAC Standby Monitor Present
6 4.849 400044000001 IBM 9B7805 LLC C D=00 S=04 TEST P
7 0.001 IBM 9B7805 400044000001 LLC R D=04 S=00 TEST F
8 0.001 400044000001 IBM 9B7805 LLC C D=04 S=04 XID P
9 0.002 IBM 9B7805 400044000001 LLC C D=00 S=04 TEST P
10 0.000 400044000001 IBM 9B7805 LLC R D=04 S=00 TEST F
11 0.001 IBM 9B7805 400044000001 LLC R D=04 S=04 XID F
12 0.001 400044000001 IBM 9B7805 SNA XID Fmt 3 T2 NETA.DSPUA
13 0.002 IBM 9B7805 400044000001 LLC C D=04 S=04 SABME P
14 0.001 400044000001 IBM 9B7805 LLC R D=04 S=04 UA F
15 0.001 IBM 9B7805 400044000001 LLC C D=04 S=04 RNR NR=0
16 0.001 IBM 9B7805 400044000001 LLC C D=04 S=04 RR NR=0
17 0.001 00 00 SNA C SC ACTPU PU5
18 0.101 00 00 SNA +R SC ACTPU
19 0.002 02 00 SNA C SC ACTLU
20 0.001 03 00 SNA C SC ACTLU
21 0.001 400044000001 IBM 9B7805 LLC R D=04 S=04 RR NR=3
22 0.000 04 00 SNA C SC ACTLU
23 0.001 00 03 SNA +R SC ACTLU
24 0.001 00 04 SNA +R SC ACTLU
25 0.099 IBM 9B7805 400044000001 LLC C D=04 S=04 RR NR=3
26 0.865 00 04 SNA C FMD NS NOTIFY
27 0.042 04 00 SNA C (FIS) FMD Application Data
28 0.001 04 00 SNA (MIS)
29 0.000 400044000001 IBM 9B7805 LLC R D=04 S=04 RR NR=6
30 0.000 04 00 SNA (MIS)
31 0.001 04 00 SNA (MIS)
32 0.000 400044000001 IBM 9B7805 LLC R D=04 S=04 RR NR=8
33 0.000 04 00 SNA (MIS)
34 0.001 04 00 SNA (MIS)
35 0.000 400044000001 IBM 9B7805 LLC R D=04 S=04 RR NR=10
36 0.001 04 00 SNA (LIS)
37 0.097 00 03 SNA C FMD NS NOTIFY
38 0.003 04 00 SNA +R FMD NS NOTIFY
39 0.041 03 00 SNA C (FIS) FMD Application Data
40 0.000 400044000001 IBM 9B7805 LLC R D=04 S=04 RR NR=13
41 0.000 03 00 SNA (MIS)
42 0.001 03 00 SNA (MIS)
43 0.000 400044000001 IBM 9B7805 LLC R D=04 S=04 RR NR=15
44 0.000 03 00 SNA (MIS)
45 0.001 03 00 SNA (MIS)
46 0.001 400044000001 IBM 9B7805 LLC R D=04 S=04 RR NR=17
47 0.000 03 00 SNA (MIS)
48 0.001 03 00 SNA (LIS)
49 0.000 400044000001 IBM 9B7805 LLC R D=04 S=04 RR NR=19
Sniffer Network Analyzer data from 10-Feb-95 at 11:07:06, unsaved capture data,
Page 2
SUMMARY Delta T Destination Source Summary
50 0.036 00 02 SNA +R SC ACTLU
51 0.013 00 04 SNA +R
52 0.000 03 00 SNA +R FMD NS NOTIFY
53 0.030 02 00 SNA C (FIS) FMD Application Data
54 0.000 400044000001 IBM 9B7805 LLC R D=04 S=04 RR NR=21
55 0.000 02 00 SNA (MIS)
56 0.002 02 00 SNA (MIS)
57 0.000 400044000001 IBM 9B7805 LLC R D=04 S=04 RR NR=23
58 0.000 02 00 SNA (MIS)
59 0.001 02 00 SNA (MIS)
60 0.001 02 00 SNA (MIS)
61 0.000 400044000001 IBM 9B7805 LLC R D=04 S=04 RR NR=25
62 0.001 02 00 SNA (LIS)
63 0.000 400044000001 IBM 9B7805 LLC R D=04 S=04 RR NR=27
64 0.078 00 03 SNA +R
65 0.054 00 02 SNA +R
66 0.044 IBM 9B7805 400044000001 LLC C D=04 S=04 RR NR=9
67 0.558 Broadcast 400044000001 MAC Active Monitor Present
68 0.000 Broadcast IBM 9B7805 MAC Standby Monitor Present
69 0.039 Broadcast This Sniffer MAC Standby Monitor Present
70 0.051 400044000001 400044000001 LOOP Reply Receipt =85
NetPro Discussion Forums - Featured Conversations
| NetPro Discussion Forums - Featured Conversations for IBM |
| Network Infrastructure: Enterprise Data Centers |
Related Information
| Updated: Sep 09, 2005 | Document ID: 12409 |