This document describes why you are unable to download BPX or IGX card firmware (getfwrev command) from a Cisco WAN Manager and a fix to enable the download.
Prerequisites
Requirements
There are no specific requirements for this document.
Components Used
This document is not restricted to specific software and hardware versions.
Conventions
Refer to Cisco Technical Tips Conventions for more information on document conventions.
The network_id Field
If the "network_id field" within config.sv is greater than 15, the getfwrev command does not download from the Cisco WAN Manager workstation. In this case, the dspdnld command shows the firmware version as unavailable.
This is fixed in SV_Rel7.2.5.Patch1.tar, which is available through from Cisco Technical Support. With this patch installed, the "network_id" can be set to a maximum value of 254.
An example config.sv is 0|Network1|sanfran|19200|0|7|3|0|30|256. The first field, containing 0, is the "network_id".