ATM and Layer 3 Module Installation Guide, 12.1(5)EY1
ATM and Layer 3 Port Adapter and Interface Module Specifications

ATM and Layer 3 Module Specifications

This appendix describes the specifications for route processors, switch processors, port adapters, carrier modules, and interface modules used in ATM and Layer 3 systems. This appendix includes the following sections:

Component Specifications

Table A-1 lists component specifications and standards compliance information for route processors, switch processors, port adapters, carrier modules, and interface modules used in the ATM and Layer 3 switch routers.


Table A-1: Component Specifications
Description Specifications

Dimensions (H x W x D)

Route processor: 1.2 x 14.4 x 16 in (3.0 x 36.6 x 40.6 cm)

Switch processor: 1.2 x 14.4 x 16 in. (3.0 x 36.6 x 40.6 cm)

Port adapter: 1.2 x 6.5 x 10 in. (3.0 x 16.5 x 25.4 cm)

Carrier module: 1.2 x 14.4 x 16 in. (3.0 x 36.6 x 40.6 cm)

Interface module: 1.2 x 14.4 x 16 in. (3.0 x 36.6 x 40.6 cm)

Interface module (OC-48c): 2.37 x 14.4 x 16.26 in.
(3.0 x 36.6 x 40.6 cm)

Weight

Route Processor: 6.85 lb (3.09 kg)

Switch processor: 3.55 lb. (1.60 kg)

Port adapter (approximately): 1.10 lb (0.50 kg)

Carrier module: 3.55 lb (1.60 kg)

Interface module: 3.55 lb (1.60 kg)

Route processor capacity

Catalyst 8540 CSR: 40-Gbps

Catalyst 8540 MSR: 20-Gbps

Catalyst 8510 CSR: 10-Gbps

Catalyst 8510 MSR: 5-Gbps

LightStream 1010: 5-Gbps

Catalyst 5500: 5-Gbps

Route processor microprocessor

100-MHz MIP1 R4700

Route processor memory
Catalyst 8500 CSR

16 MB Flash memory SIMM2
256 KB boot EPROM3
128 KB SRAM4
8-, 16-, or 20-MB Intel series 2+ Flash PC Cards
Catalyst 8540 CSR: 256 MB DRAM5
Catalyst 8510 CSR: 64 MB DRAM

Route processor memory
Catalyst 8500 MSR, Lightstream 1010,
and Catalyst 5500

8-MB Flash memory SIMM
32 MB DRAM default for FC-PCQ
64 MB DRAM default for FC-PFQ
256 KB boot EPROM
128 KB SRAM
8-, 16-, or 20 MB Intel Series 2+ Flash PC Card

Operating temperature

32 to122ºF (0 to 50ºC)

Nonoperating temperature

-40 to 167ºF (-40 to 75ºC)

Humidity

10 to 90%, noncondensing

Altitude

-500 to 10,000 ft (-52 to 3048 m)

Interface timing

Loop timing, Stratum 4 accuracy clock for self-timing; synchronous, SRTS6, or adaptive clocking for CBR7 traffic

Interface ports

RJ-45 IEEE 802.3 Ethernet 10BaseT port
DB-25 console port for an administration workstation

MIBs

SNMP8MIB II (RFC 1213), Interface table MIB (RFC 1573), CISCO-CDP-MIB, CISCO-BRIDGE-MIB

1MIP = MultiChannel Interface Processor
2SIMM = single in-line memory module
3EPROM = erasable programmable read-only memory
4SRAM = static random-access memory
5DRAM = dynamic random-access memory
6SRTS = synchronous residual time stamp
7CBR = constant bit rate
8SNMP = Simple Network Management Protocol


Agency Approvals

Table A-2 lists the agency approvals and electromagnetic interference (EMI) specifications for the ATM and Layer 3 systems.


Table A-2: Regulatory Compliance Standards for the ATM and Layer 3 Systems
Description System Specifications

Compliance

ATM

Layer 3

CE Marking

Safety

ATM

Layer 3

UL 19501, 21CFR10402, CSA 9503, EN60825, IEC609504, IEC 60325, AS/NZS 32605, EN 609506, TS 0017,

EMC standards

ATM

Layer 3

With UTP cables:

  • FCC Part 15 Class A (CFR 47, Part 15)

  • CISPR 22 Class A

  • EN 55022 Class A

  • VCCI Class A

  • AS/NZS 3548 Class A

With FTP cables:

  • EN 55022 Class B

  • CISPR 22 Class B

  • VCCI Class B

  • ENSS024

  • ENS0082-1 (1997)

1UL = Underwriters Laboratories
2CFR = Code of Federal Regulations
3CSA = Canadian Standards Association
4IEC = International Electrotechnical Commission
5AS/NZS = Australia/New Zealand Standards
6EN = European Norm
7TS = Technical Standard


Heat Dissipation and Watts

Table A-3 lists the heat dissipation and watts for the ATM and Layer 3 port adapters and interface modules.The following numbers are based on a 48VDC as the reference for the current.


Table A-3: Module Power Consumption
Port Adapters and Interface Modules Product Number Heat Dissipation
Current Watts

25-Mbps port adapters

C85MS-ATM25-4P
WAI-ATM25-12P

0.2A

9.6W

155-Mbps port adapters

WAI-OC-3-4MM
WAI-OC-3-4SM
WAI-OC3-1S3M
WAI-C3-4U5

0.2A

9.6W

16-port OC-3c interface modules

C85MS-16F-OC3MM

0.4A

19.2W

622-Mbps port adapters

WAI-OC12-1SM
WAI-OC12-1MM

0.2A

9.6W

Four-port OC-12c interface module

C85MS-4F-OC12SS
C85MS-4F-OC12MM

0.5A

24W

OC-48c (1 OC-48c plus 4 OC-12c port or 2 OC-48c port) interface modules

C85MS-2F-OC48LR
C85MS-1F4S-OC48LR
C85MS-2F-OC48SS
C85MS-1F4S-OC48SS
C85MS-1F4M-OC48SS

1.7A

81.6W

T1 and E1 port adapters

WAI-E1-4RJ48
WAI-T1-4RJ48
WAI-E1-4BNC

0.2A

9.6W

Eight-port T1 and E1 IMA port adapters

C85MS-8T1-IMA
C85MS-8E1-IMA-120

0.4A

19.2W

CE1 Frame Relay port adapters

C85MS-4E1-FRRJ48

0.2A

9.6W

CES T1 and E1 port adapters

WAI-E1C-4BNC
WAI-E1C-4RJ48
WAI-T1C-4RJ48

0.2A

9.6W

DS3 and E3 port adapters

WAI-T3-2BNC
WAI-T3-4BNC
WAI-E3-2BNC
WAI-E3-4BNC

0.2A

9.6W

CDS3 Frame Relay port adapters

C85MS-1DS3-FRBNC

0.2A

9.6W

Enhanced Catalyst 8540 ATM Router Module1

C8540-ARM2

1.5A

72W

Catalyst 8540 ATM Router Module2

C8540-ARM

1.5A

72W

Catalyst 8510 ATM Router Module3, 4

C8510-ARM

0.5A

24W

Two-port Gigabit Ethernet interface modules

C85GE-2X-16K
C85GE-2X-64K

2A

96W

Eight-port Gigabit Ethernet interface modules

C85GE-8X-64K

3A

144W

Two-port Enhanced Gigabit Ethernet interface modules

C85GE-2X-16K
C85EGE-2X-64K
C85EGE-2X-256K

2A

96W

One-port Gigabit Ethernet interface modules

C85GE-1X-16K
C85GE-1X-64K

0.4A

19.2W

16-port 10/100BASE-T interface modules

C85FE-16T-16K
C85FE-16T-64K

2A

96W

Eight-port 10/100BASE-T interface modules

C85FE-8T-16K
C85FE-8T-64K

0.4A

19.2W

16-port 100BASE-FX interface modules

C85FE-16F-16K
C85FE-16F-64K

1.7A

81.6W

Eight-port 100BASE-FX interface modules

C85FE-8F-16K
C85FE-8F-64K

1A

48W

OC-3c or OC-12c ATM uplink with enhanced Gigabit Ethernet interface modules

C85-10C12SGE-256K
C85-1OC12MGE-256K
C85-10C12MGE-64K
C85-10C3GE-64K

2A

96W

OC-12c Packet-over-SONET uplink with enhanced Gigabit Ethernet interface modules

C85-POSOC12I-64K
C85-POSOC12I-256K
C85-POSOC12L-64K
C85-POSOC12L-256K

2A

96W

1Two internal ports, Ethernet processor interface.
2Two internal ports, Gigabit processor interface.
3One internal port. The ATM router module is not supported on the Catalyst 5500.
4The LightStream 1010 system software image does not include support for the ATM router module or Layer 3 features. You can download the Catalyst 8510 MSR image to a LightStream 1010 ATM switch router with ASP-C and FC-PFQ installed.


Module Part Numbers

Table A-4 lists the component number, type of ports, and their part numbers for the ATM and Layer 3 systems.


Table A-4: Port Adapter and Interface Module and Part Numbers
Component No. and
Type of Ports
Connectors Part No.

Catalyst 8540 route processor

1 Ethernet

RJ-45

C8541CSR-RP

Catalyst 8540 multiservice route processor

1 Ethernet

RJ-45

C8545MSR-MRP4CLK

Catalyst 8540 multiservice route processor stratum 3

1 Ethernet

RJ-45

C8545MSR-MRP3CLK

Catalyst 8510 CSR Route Processor

1 Ethernet

RJ-45

C8510-SRP

Catalyst 8510 MSR Route Processor

1 Ethernet

RJ-45

C8515-MSRP

Route Processor

1 Ethernet

RJ-45

C8515-MSRP (Catalyst 8510 MSR)

LightStream 1010 Route Processor with FC-Per-Class Queuing

1 Ethernet

RJ-45

L1010-ASP-C-FC1

LightStream 1010 Route Processor with FC-Per-Flow Queuing

1 Ethernet

RJ-45

L1010-ASP-C-FCPFQ

Catalyst 8540 CSR Switch Processors

C8542CSR-SP

Catalyst 8540 MSR Switch Processor

C8546MSR-MSP-FCL

25-Mbps port adapter

4 25-Mbps ports

RJ-45 connectors

C85MS-ATM25-4P

12 25-Mbps ports

RJ-45 connectors

WAI-ATM25-12P

155-Mbps port adapter

4 SONET STS-3c/SDH STM-1 multimode fiber ports

SC connectors

WAI-OC-3-4MM

4 SONET STS-3c/SDH STM-1 single-mode fiber ports1

SC connectors

WAI-OC-3-4SM

4 SONET STS-3c/SDH STM-1:
1 single-mode,
3 multimode fiber ports

SC connectors

WAI-OC3-1S3M

4 SONET STS-3c/SDH STM-1 UTP-5 ports

RJ-45 connectors

WAI-C3-4U5

16-port OC-3c interface module

16 SONET STS-3c/SDH STM-1 multimode fiber port

MT-RJ connectors

C85MS-16F-OC3MM

622-Mbps port adapter

1 SONET STS-12c/SDH STM-4c single-mode fiber port1

SC connectors

WAI-OC12-1SM

1 SONET STS-12c/SDH STM-4c multimode fiber port

SC connectors

WAI-OC12-1MM

Four-port OC-12c interface module

4 SONET STS-12c/SDH STM-4c single-mode fiber port

Dual SC connectors

C85MS-4F-OC12SS

4 SONET STS-12c/SDH STM-4c multimode fiber port

Dual SC connectors

C85MS-4F-OC12MM

OC-48c interface module

2 SONET STS-48c/SDH STM-16c
single-mode fiber port

Dual SC connectors

C85MS-2F-OC48LR

C85MS-1F4S-OC48LR

2 SONET STS-48/SDH STM-16c
single-mode fiber port

Dual SC connectors

C85MS-2F-OC48SS

1 SONET STS-48c/SDH STM-16c
single-mode fiber port

Dual SC connectors

C85MS-1F4S-OC48SS

4 SONET STS-12c/SDH STM-4c
single-mode fiber port

Dual SC connectors

1 SONET STS-48c/SDH STM-16c
single-mode fiber port

Dual SC connectors

C85MS-1F4M-OC48SS

4 SONET STS-12c/SDH STM-4c
multimode fiber port

Dual SC connectors

T1 and E1 port adapters

4 E1 trunk ports

RJ-48 connectors

WAI-E1-4RJ48

4 T1 trunk ports

RJ-48 connectors

WAI-T1-4RJ48

4 E1 trunk ports

BNC connectors

WAI-E1-4BNC

Eight-port T1 and E1 IMA port adapter

8 T1 ports

RJ-48 connectors

C85MS-8T1-IMA

8 E1 ports

RJ-48 connectors

C85MS-8E1-IMA-120

CE1 Frame Relay port adapter

4 CE1 ports

RJ-48c connectors

C85MS-4E1-FRRJ48

CES T1 and E1 port adapters

4 E1 CES ports

BNC connectors

WAI-E1C-4BNC

4 E1 CES ports

RJ-48 connectors

WAI-E1C-4RJ48

4 T1 CES ports

RJ-48 connectors

WAI-T1C-4RJ48

DS3 and E3 port adapters

2 DS3 ports

BNC connectors

WAI-T3-2BNC

4 DS3 ports

BNC connectors

WAI-T3-4BNC

2 E3 ports

BNC connectors

WAI-E3-2BNC

4 E3 ports

BNC connectors

WAI-E3-4BNC

CDS3 port adapter

1 DS3 Frame Relay port

BNC connectors

C85MS-1DS3-FRBNC

Enhanced Catalyst 8540 MSR ATM Router Module

2 256 KB Ethernet processor ports (internal)

C8540-ARM2

Catalyst 8540 ATM Router Module

2 64 KB Gigabit processor ports (internal)

C8540-ARM

Catalyst 8510 MSR ATM Router Module

1 64 KB Gigabit processor port (internal)

C8510-ARM

Eight-port Gigabit Ethernet interface module

8-port GE 64 KB

SC-type

C85GE-8X-64K

Two-port Gigabit Ethernet interface module

2-port GE 16 KB

SC-type

C85GE-2X-16K

2-port GE 64 KB

SC-type

C85GE-2X-64K

Two-port Gigabit Ethernet with ACL

2-port GE 16 KB with ACL

SC-type

C85GE-2XACL-16K

2-port GE 64 KB with ACL

SC-type

C85GE-2XACL-64K

Two-port enhanced Gigabit Ethernet interface module

2-port GE 16 KB

SC-type

C85GE-2X-16K

2-port GE 64 KB

SC-type

C85EGE-2X-64K

2-port GE 256 KB

SC-type

C85EGE-2X-256K

One-port Gigabit Ethernet interface module

1-port GE 16 KB

SC-type

C85GE-1X-16K

1-port GE 64 KB

SC-type

C85GE-1X-64K

16-port 10/100BASE-T interface module

16-port FE 16 KB

RJ-45

C85FE-16T-16K

16-port FE 64 KB

RJ-45

C85FE-16T-64K

16-port 10/100BASE-T interface module with ACL

16-port FE 16 KB with ACL

RJ-45

C85FE-16TACL-16K

16-port FE 64 KB with ACL

RJ-45

C85FE-16TACL-64K

Eight-port 10/100BASE-T interface module

8-port FE 16 KB

RJ-45

C85FE-8T-16K

8-port FE 64 KB

RJ-45

C85FE-8T-64K

16-port 100BASE-FX interface module

16-port FE 16 KB

MT-RJ

C85FE-16F-16K

16-port FE 64 KB

MT-RJ

C85FE-16F-64K

16-port 100BASE-FX interface module with ACL

16-port FE 16 KB with ACL

MT-RJ

C85FE-16FACL-16K

16-port FE 64 KB with ACL

MT-RJ

C85FE-16FACL-64K

Eight-port 100BASE-FX interface module

8-port FE 16 KB

MT-RJ

C85FE-8F-16K

8-port FE 64 KB

MT-RJ

C85FE-8F-64K

One-port ATM Uplink with enhanced Gigabit Ethernet interface modules (OC-3c and OC-12c)

1-port ATM OC-12 SMF-IR Uplink + 1-port GE 256 KB

SC-type

C85-10C12SGE-256K

1-port ATM OC12 SMF-IR Uplink + 1-port GE 64 KB

SC-type

C85-10C12SGE-64K

1-port ATM OC12 MMF Uplink + 1-port GE 256 KB

SC-type

C85-1OC12MGE-256K

1-port ATM OC-12 MMF Uplink + 1-port GE 64 KB

SC-type

C85-10C12MGE-64K

1-port ATM OC3 SMF-IR Uplink + 1-port GE 64 KB

SC-type

C85-10C3GE-64K

One-port Packet-over-SONET (POS) uplink with enhanced Gigabit Ethernet interface module (OC-12c)

1-port POS OC12 STM-4 SMF-IR + 1-port GE 64 KB

SC-type

C85-POSOC12I-64K

1-port POS OC12 STM-4 SMF-IR + 1-port GE 256 KB

SC-type

C85-POSOC12I-256K

1-port POS OC12 STM-4 SMF-LR + 1-port GE 64 KB

SC-type

C85-POSOC12L-64K

1-port POS OC12 STM-4 SMF-LR + 1-port GE 256 KB

SC-type

C85-POSOC12L-256K

1Available in intermediate and long reach fiber


Maximum Station-to-Station Cabling Distances

When you prepare your site for network connections to the switch router, consider the distance limitations for each signal type and the cabling required for each type of interface. Additional equipment needed might include transceivers, modems, channel service units (CSUs) or data service units (DSUs). You might need connections not provided by service providers, such as a network termination unit (NTU) for T1, E1, DS3, and E3 port adapters.

The length of your networks and the distances between connections depends on the type of signal, the signal speed, and the transmission media (the type of cabling used to transmit the signals). For example, multimode fiber-optic cable has a greater channel capacity than unshielded twisted-pair (UTP) cabling.


Note   The distances and rate limits in this appendix are the IEEE-recommended maximum speeds and distances for signaling. However, you can get good results at speeds and distances far greater than these if you understand and can compensate for the electrical problems that might arise. Do so at your own risk.

Networking standards set recommended maximum distances between stations using fiber-optic and UTP cable. The maximum distances for network segments and connections depend on the type of transmission cable used; for example, unshielded twisted-pair (UTP), foil twisted-pair (FTP), single-mode, or multimode fiber-optic cable.

Table A-5 lists maximum station-to-station cabling distances and cable types for port adapters and interface modules used in ATM and Layer 3 systems.


Table A-5: Maximum Station-to-Station Cabling Distances
ATM Port Adapter and
Interface Module
Cable Cabling Distance

25-Mbps

Category 5 UTP cable

328 ft (100 m) with four or fewer separate cable segments on the path

OC-3c, 155 Mbps

Category 5 UTP cable

328 ft (100 m)

OC-3c, 155 Mbps

9/125 micron single-mode fiber

9 miles (15 km)

OC-3c, 155 Mbps

9/125 micron single-mode fiber, extended reach plus

18 miles (30 km)

OC-3c, 155 Mbps

9/125 micron single-mode fiber, long reach

25 miles (40 km)1

OC-3c, 155 Mbps

9/125 micron multimode fiber, long reach

1.2 miles (2km)

OC-12c, 622 Mbps

Single-mode fiber

9 miles (15 km)1

OC-12c, 622 Mbps

50/125-micron and 62.5/125-micron multimode fiber

1640 ft (500 m)

OC-48c, 2488 Mbps

Single-mode fiber, intermediate reach

9 miles (15 km)
intermediate reach

OC-48c, 2488 Mbps

Single-mode fiber, long reach

50 miles (80 km)1

T1, 1.544 Mbps

Category 5 twisted-pair

650 ft (198 m)

E1, 2.048 Mbps

Category 5 twisted-pair and FTP (120 ohms)

650 ft (198 m)

E1, 2.048 Mbps

Coaxial cable (75 ohms)

650 ft (198 m)

CE1, 2.048 Mbps

Category 5 twisted-pair

650 ft (198 m)

CES T1

Category 5 twisted-pair and FTP

650 ft (198 m)
(5.5 dB attenuation at 772 kHz), 100-ohm, 24 AWG2, UTP cable with RJ3-48c connectors

CES E1

Category 5 twisted-pair and FTP

820 ft (248.5 m)
(6 dB attenuation at 1024 kHz), 100 ohm, 24 AWG, UTP cable with RJ-48c connectors

CES E1

Coaxial cable (75 ohms)

650 ft (198 m)

DS3, 45 Mbps

Coaxial cable

450 ft (137 m)

E3, 34 Mbps

Coaxial cable

1299 ft (396 m)

CDS3, 45 Mbps

Coaxial cable

450 ft (137 m)

8-port Gigabit Ethernet

Multimode or single-mode fiber

1640 ft (500 m) or 16404 ft (5 km)

2-port Gigabit Ethernet

Multimode or single-mode fiber

1640 ft (500 m) or 16404 ft (5 km)

2-port enhanced Gigabit Ethernet

Multimode or single-mode fiber

1640 ft (500 m) or 16404 ft (5 km)

16-port 10/100BASE-T Ethernet

UTP cable

328 ft (100 m) with 4 or fewer separate cable segments on the path

16-port 100BASE-FX Ethernet

Multimode fiber

1640 ft (500 m)

1-port ATM OC-3c uplink

Multimode or single-mode fiber

1640 ft (500 m) or 16404 ft (5 km)

1-port ATM OC-12c uplink

Multimode or single-mode fiber

1640 ft (500 m) or 16404 ft (5 km)

1-port Packet-over-SONET OC-12c uplink

Single-mode fiber

16404 ft (5 km)

8-port 10/100BASE-T Ethernet

UTP cable

328 ft (100 m) with 4 or fewer separate cable segments on the path

8-port 100BASE-FX Ethernet

50/125-micron and 62.5/125-micron multimode fiber

6562 ft (2 km)

1-port Gigabit Ethernet

Multimode fiber

1640 ft (500 m)

1If attaching a short cable to this port adapter or interface module, you must add 10 dB of attenuation to the cable or the transmitter might overdrive the receiver and introduce data errors.
2AWG = American Wire Gauge
3RJ = registered jack


GBIC Cable Distances and Modal Bandwidths

A GBIC has two pinouts: receive and transmit. The connectors are multimode fiber or single-mode fiber. Table A-6 lists the cable distances and modal bandwidth for GBICs.


Table A-6: GBIC Cable Distances and Modal Bandwidths
GBIC Wavelength (nm1) Fiber Type Core Size (microns) Modal Bandwidth (MHz2-km) Cable Distance

SX3,4

850

MMF

SMF

62.5

62.5

50.0

50.0

160

200

400

500

722 ft (200 m)

902 ft (275 m)

1620 ft (500 m)

1804 ft (550 m)

LX/LH5

1300

MMF

SMF6 (LX/LH)

62.5

50.0

50.0

9/10

500

400

5000

1804 ft (550 m)

1804 ft (550 m)

1804 ft (550 m)

32,810 ft (10 km)

ZX7

1550

SMF

Not conditional

70 to 100 km

1nm = nanometers
2MHz-km = Signal bandwidth in MHz transmitted over a distance of 1 km
3SX = short wavelength
4MMF = multimode fiber
5LX/LH = long wavelength/long haul
6SMF = single-mode fiber
7ZX = extended distance


Fiber-Optic Power Levels

Table A-7 lists fiber-optic power levels for port adapters and interface modules used in ATM and Layer 3 systems. To attach long reach port adapters or interface modules using single-mode fiber, measure the power level of the transmitter and adjust it by using optical attenuators.


Caution   Add a 10 dB attenuator at the interface to adjust the power level, or the transmitter overdrives the receiver and introduces data errors.


Table A-7: Fiber-Optic Power Levels
Port Output Center
Wavelength
Transmit Receive

OC-3c SM

1261 to 1360 nm1

Minimum: -15.0 dBm2

Maximum: -8.0 dBm

Minimum: -27.0 dBm

Maximum: -8.0 dBm

OC-3c SM long reach

1281 to 1380 nm

Minimum: -5.0 dBm

Maximum: 0.0 dBm

Minimum: -34.0 dBm

Maximum: -10.0 dBm

OC-3c MM

1270 to 1380 nm

Minimum: -20.0 dBm

Maximum: -14.0 dBm

Minimum: -27.0 dBm

Maximum: -14.0 dBm

OC-12c SM intermediate reach

1293 to 1334 nm

Minimum: -15.0 dBm

Maximum: -8.0 dBm

Minimum: -28.0 dBm

Maximum: -3.0 dBm

OC-12c SM extended reach

1274 to 1356 nm

Minimum: -15.0 dBm

Maximum: -8.0 dBm

Minimum: -28.0 dBm

Maximum: -8.0 dBm

OC-12c MM

1270 to 1380 nm

Minimum: -20.0 dBm

Maximum: -14.0 dBm

Minimum: -26.0 dBm

Maximum: -14.0 dBm

OC-12c SM long reach

1280 to 1335 nm

Minimum: -3.0 dBm

Maximum: 2.0 dBm

Minimum: -28.0 dBm

Maximum: -8.0 dBm

OC-48c SM intermediate reach

1260 to 1360 nm

Minimum: -5.0 dBm

Maximum: 0.0 dBm

Minimum: -18.0 dBm

Maximum: 0.0 dBm

OC-48c SM long reach

1500 to 1580 nm

Minimum: -2.0

Maximum: 3.0 dBm

Minimum: -28.0 dBm

Maximum:- 9.0 dBm

8-port Gigabit Ethernet

1261 to 1360 nm

Minimum: -15.0 dBm

Maximum: -8.0 dBm

Minimum: -28.0 dBm

Maximum: -8.0 dBm

2-port Gigabit Ethernet

1261 to 1360 nm

Minimum: -15.0 dBm

Maximum: -8.0 dBm

Minimum: -28.0 dBm

Maximum: -8.0 dBm

2-port enhanced Gigabit Ethernet

1261 to 1360 nm

Minimum: -15.0 dBm

Maximum: -8.0 dBm

Minimum: -28.0 dBm

Maximum: -8.0 dBm

8-port 100BASE-FX

1261 to 1360 nm

Minimum: -15.0 dBm

Maximum: -8.0 dBm

Minimum: -28.0 dBm

Maximum: -8.0 dBm

1-port Gigabit Ethernet

1261 to 1360 nm

Minimum: -15.0 dBm

Maximum: -8.0 dBm

Minimum: -28.0 dBm

Maximum: -8.0 dBm

1nm = nanometers
2dBm = decibels per milliwatt