Table of Contents
Technical Specifications
Table A-1, Table A-2, and Table A-3, list the technical specifications for the Catalyst 3500 series XL switches. Table A-4 lists the regulatory agency approvals.
Table A-1: Technical Specifications for the Catalyst 3508G XL Switch
| Environmental Ranges |
|
|
Operating temperature
|
32 to 113°F (0 to 45°C)
|
|
Storage temperature
|
-4 to 149°F (-10 to 65°C)
|
|
Operating humidity
|
10 to 85% (noncondensing)
|
|
Operating altitude
|
Up to 10,000 ft (3000 m)
|
|
Storage altitude
|
Up to 15,000 ft (4570 m)
|
| Power Requirements |
|
|
AC input voltage
|
100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz
|
|
DC input voltages
|
+3.3V

@14A,
+12V

@3A
|
|
Power consumption
|
82.2W
280 Btus per hour
|
| Physical Dimensions |
|
|
Weight
|
12 lb (5.45 kg)
|
|
Dimensions (H x W x D)
|
1.75 x 16 x 17.5 in.
(4.45 x 40.46 x 44.45 cm)
|
Table A-2: Technical Specifications for the Catalyst 3512, 3524, and 3548 XL Switches
|
Catalyst 3512 XL |
Catalyst 3524 XL |
Catalyst 3548 XL |
| Environmental Ranges |
|
|
Operating temperature
|
32 to 113°F (0 to 45°C)
|
32 to 113°F (0 to 45°C)
|
32 to 113°F (0 to 45°C)
|
|
Storage temperature
|
-4 to 149°F (-10 to 65°C)
|
-4 to 149°F (-10 to 65°C)
|
-4 to 149°F (-10 to 65°C)
|
|
Relative humidity
|
10 to 85% (noncondensing)
|
10 to 85% (noncondensing)
|
10 to 85% (noncondensing)
|
|
Operating altitude
|
Up to 10,000 ft (3000 m)
|
Up to 10,000 ft (3000 m)
|
Up to 10,000 ft (3000 m)
|
|
Storage altitude
|
15,000 ft (4570 m)
|
15,000 ft (4570 m)
|
15,000 ft (4570 m)
|
| Power Requirements |
|
|
AC input voltage
|
100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz
|
100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz
|
100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz
|
|
DC input voltages
|
+5V

@8.0A,
+12V

@0.5A
|
+5V

@10A,
+12V

@0.5A
|
+3.3V

@17A
+12V

@1.1A
|
|
Power consumption
|
50W
171 Btus per hour
|
75W
256 Btus per hour
|
100W
600 Btus per hour
|
| Physical Dimensions |
|
|
Weight
|
10.25 lb (4.65 kg)
|
8.5 lb (3.86 kg)
|
12 lb (5.45 kg)
|
|
Dimensions (H x D x W)
|
1.75 x 11.82 x 17.5 in.
(4.45 x 30.02 x 44.45 cm)
|
1.75 x 11.82 x 17.5 in.
(4.45 x 30.02 x 44.45 cm)
|
1.73 x 15.34 x 17.5 in
(4.39 x 39.0 x 44.45 cm)
|
Table A-3: Technical Specifications for the Catalyst 3524-PWR XL Switch
| Environmental Ranges |
|
|
Operating temperature
|
32 to 113°F (0 to 45°C)
|
|
Storage temperature
|
-4 to 149°F (-10 to 65°C)
|
|
Operating humidity
|
10 to 85% (noncondensing)
|
|
Operating altitude
|
Up to 10,000 ft (3000 m)
|
|
Storage altitude
|
Up to 15,000 ft (4570 m)
|
| Power Requirements |
|
|
AC input voltage
|
100 to 127/200 to 240 VAC
(autoranging) 50 to 60 Hz
|
|
DC input voltages
|
-48V

@3A,
+12V

@6A
|
|
Power consumption
|
325W1
1100 Btus per hour
|
| Physical Dimensions |
|
|
Weight
|
10.25 lb (4.65 kg)
|
|
Dimensions (H x W x D)
|
1.75 x 11.82 x 17.5 in.
(4.45 x 30.02 x 44.45 cm)
|
1The actual power consumption depends on the number of IP phones connected. 325W represents 24 IP phones connected.
|
Table A-4: Catalyst 3500 Series XL Agency Approvals
| Safety |
EMC |
|
UL to UL 1950, Third Edition
|
FCC Part 15 Class A
|
|
c-UL to CAN/CSA 22.2 No. 950-95, Third Edition
|
EN 55022 Class A (CISPR 22 Class A)
|
|
TUV/GS to EN 60950 with Amendment A1-A4 and A11
|
VCCI Class A
|
|
ACA/A2LA to AS/NZS 3260 and TS001-1997
|
AS/NZS 3548 Class A
|
|
CB to IEC 60950 with all country deviations
|
BSMI
|
|
NOM to NOM-019-SCFI
|
CE Marking
|
|
CE Marking
|
|