Table Of Contents
BPX Switch Cabling Summary
Trunk Cabling
Power Cabling
AC Powered Nodes
DC Powered Nodes
LM-BCC Cabling
Auxiliary and Control Port Cabling
LAN Port Cabling
Modem Cabling
External Clock Input Cabling
External Alarm Cabling
Standard BPX Switch Cables
Redundancy "Y" Cable
BPX Switch Cabling Summary
This chapter specifies the cabling required to install the BPX switch.
Contents of this chapter include:
•
Trunk Cabling
•
Power Cabling
•
LM-BCC Cabling
•
External Alarm Cabling
•
Standard BPX Switch Cables
•
Redundancy "Y" Cable
Note
In all cable references:
The Transmit direction is from the BPX switch.
The Receive direction is to the BPX switch.
Trunk Cabling
Trunk cables connect the customer DSX-3 crossconnect point or T3-E3 Interface Module to the BPX switch at the LM-3T3 back card (see Table 31-1).
Table 31-1 Trunk Cables
Cable Parameter
|
Description
|
Type:
|
75-ohm coax cable (RG-59 B/U for short runs, AT&T 734A for longer runs). Two per T3/E3 line (XMT and RCV).
For European shipment of the BXM-E3 cards, in order to meet CE mark transient test requirement (IEC1000-4-4), RG-17G double shielded SMB cable must be used.
|
Max. Length:
|
450 feet max. between the BPX switch and the DSX-3/E3 point.
|
Connector:
|
Terminated in male BNC; Rx is receive from trunk, Tx is transmit to trunk.
|
Power Cabling
Power connections are made to the AC Power Supply Shelf or the DC Power Entry Module at the rear of the BPX switch. For acceptable cable and wire types, see Table 31-2 and Table 31-3.
AC Powered Nodes
AC power cables may be provided by you or ordered from Cisco. Several standard cables are available (see Table 31-2). AC cables with other plugs or different lengths may be special ordered.
For those who wish to construct their own power cable, the cable must mate with an IEC320 16/20A male receptacle on the rear of the AC Power Supply Assembly.
Table 31-2 AC Power Cables
Cable Parameter
|
Description
|
Cable:
|
Provided with 8 feet (2.3 m.) of 3-conductor wire with plug.
|
Plug: customer end
|
20 A NEMA L620, 3-prong plug (domestic) or 13 A 250 Vac BS1363, 3-prong fused plug (UK, Ireland) CEE 7/7 (Continental Europe) AS3112 (Australia/New Zealand) CEI23-16/VII (Italy)
|
DC Powered Nodes
DC wiring is generally provided by the customer. Table 31-3 lists the cable parameters.
Table 31-3 DC Power Wiring
Cable Parameter
|
Description
|
Wiring:
|
Single conductor, 8 AWG recommended wire gauge, 75×C insulation rating, copper conductors only. Provision is provided for attaching conduit.
|
Connection:
|
90× ring lug for #10 screw terminal block.
|
LM-BCC Cabling
LM-BCC cabling connects data ports on the LM-BCC to control terminals and modems. It is also used for external clock inputs from a clock source.
See for more details on peripherals that can be attached to these ports.
Auxiliary and Control Port Cabling
The auxiliary and control ports are used to connect one of the nodes in the network to a control terminal or modem connections for remote alarm reporting or system monitoring. For details on this cable, see Table 31-4 and Table 31-5.
Table 31-4 Auxiliary and Control Port Cabling
Cable Parameter
|
Description
|
Interface:
|
RS-232 DCE ports.
|
Suggested Cable:
|
24 AWG, 25-wire. A straight-through RS-232 cable is used for a terminal or printer connection. A null modem cable may be needed when interfacing with modems on either port.
|
Cable Connector:
|
DB-25, subminiature, male. Table 31-5 contains a list of the port pin assignments.
|
Max. Cable Length:
|
50 feet (15 m)
|
The auxiliary and control port pin assignments are listed in Table 31-5.
Table 31-5 Auxiliary and Control Port Pin Assignments
Pin#
|
Name
|
Source
|
Description
|
1
|
FG
|
both
|
Frame Ground
|
2
|
TxD
|
DTE
|
Transmit Data
|
3
|
RxD
|
DCE
|
Receive Data
|
4
|
RTS
|
DTE
|
Request to Send
|
5
|
CTS
|
DCE
|
Clear to Send
|
6
|
DSR
|
DCE
|
Data Set Ready
|
7
|
SG
|
both
|
Signal Ground
|
8
|
CD
|
DCE
|
Carrier Detect
|
20
|
DTR
|
DTE
|
Data Term Ready
|
LAN Port Cabling
The LAN connection is used to connect one of the nodes in the network to a Cisco WAN Manager NMS workstation (see Table 31-6 and Table 31-7).
Table 31-6 LAN Port Cabling
Cable Parameter
|
Description
|
Interface:
|
Ethernet DCE port.
|
Suggested Cable:
|
TBS
|
Cable Connector:
|
DB-15, subminiature, male. Table 31-7 contains a list of the port pin assignments.
|
Max. Cable Length:
|
50 feet (15 m.) max. to interface adapter.
|
The LAN port pin assignments are listed in Table 31-7.
Table 31-7 LAN Port Pin Assignments
Pin #
|
Name
|
Pin #
|
Name
|
1
|
Shield
|
—
|
—
|
2
|
Collision Presence +
|
9
|
Collision Presence -
|
3
|
XMT +
|
10
|
XMT -
|
4
|
Reserved
|
11
|
Reserved
|
5
|
RCV +
|
12
|
RCV -
|
6
|
Power return
|
13
|
Power (+12V)
|
7
|
Reserved
|
14
|
Reserved
|
8
|
Reserved
|
15
|
Reserved
|
Modem Cabling
For modem cabling information, see "Connecting Temporary Terminal and Attaching Peripherals."
External Clock Input Cabling
This cabling is for making external clock connections for use by the BCC-32 and BCC-4 back cards.
The BCC-32 uses the BCC-bc back card.
The discontinued BCC-3 and BCC-4 both use the BCC-3-bc back card.
Note
The clock output from the BPX 8600 external clock connector is not a T1 or E1 pulse stream. It is a TIA 422A square wave at T1or E1 rates (i.e. a square wave at either 1.544 Mbps or 2.048 Mbps.)
T1 Clock Cabling
Table 31-8 through Table 31-11 lists T1 clock cabling details.
Table 31-8 External Clock Cabling
Cable Parameter
|
Description
|
Cable Type:
|
22 AWG, ABAM individually shielded twisted pair. Two pair per T1 line (1 transmit and 1 receive).
|
Cable Connector:
|
Male DB-15 subminiature. See Table 31-10 through Table 31-11 for pinouts.
|
Max. Cable Length:
|
533 ft (162 m.) maximum between the BPX switch and the first repeater or CSU. Selection of cable length equalizers.
|
Table 31-9 T1 Connection to XFER TMG on BCC-bc
Pin #
|
Description
|
1
|
Transfer timing ring
|
2
|
Transfer timing tip
|
3 & 4
|
Transfer timing shield
|
Table 31-10 T1 Connection to EXT TMG on BCC-bc
Pin #
|
Description
|
2
|
Receive pair shield
|
3
|
Receive tip
|
11
|
Receive ring
|
Table 31-11 T1 Connection to EXT 1 or EXT 2 on BCC-3-bc
Pin #
|
Description
|
Function
|
1
|
Transmit tip
|
Transmit T1 timing signal synchronized to the node
|
2
|
Transmit pair shield
|
|
3
|
Receive tip
|
Receive clock for synchronized clock source for node
|
4
|
Receive pair shield
|
|
7
|
Transfer timing tip
|
|
8
|
Transfer timing shield
|
|
9
|
Transmit ring
|
|
11
|
Receive ring
|
|
15
|
Transfer timing ring
|
|
E1 Clock Cabling
Table 31-12 through Table 31-15 lists E1 clock cabling details.
Table 31-12 E1 Connector Pin Assignments for External Clock
Connector
|
Description
|
Cable Type:
|
75-ohm coax cable for unbalanced connection or 100-120-ohm twisted pair for balanced connection. Two cables/pairs (1 transmit, 1 receive) per E1 line.
|
Cable Connector:
|
Two female BNC for unbalanced connection; male DB15 for balanced connection. See Table 31-13 and Table 31-15 for pinouts.
|
Max. Cable Length:
|
Approximately 100 meters maximum between the BPX switch and the first repeater or CSU. Equalizer for cable length.
|
Table 31-13 E1 Connection 75 Ohm to EXT TMG on BCC-bc or BCC-3-bc
Connector
|
Description
|
BNC
|
Receive E1 from trunk
|
Table 31-14 E1 Connection 100/120 Ohm to EXT TMG on BCC-bc
Pin #
|
Description
|
2
|
Receive pair shield
|
3
|
Receive tip
|
11
|
Receive ring
|
Table 31-15 E1 Connection 100/120 Ohm to EXT 1 or EXT 2 on BCC-3-bc
Pin #
|
Description
|
Function
|
1
|
Transmit tip
|
Transmit T1 timing signal synchronized to the node
|
2
|
Transmit pair shield
|
|
3
|
Receive tip
|
Receive clock for synchronized clock source for node
|
4
|
Receive pair shield
|
|
7
|
Transfer timing tip
|
|
8
|
Transfer timing shield
|
|
9
|
Transmit ring
|
|
11
|
Receive ring
|
|
15
|
Transfer timing ring
|
|
External Alarm Cabling
This cable (see Table 31-16) is for connecting network alarm outputs to the LM-ASM ALARM OUTPUT connector only. Table 31-17 lists the pinouts for the network alarm outputs.
Table 31-16 External Alarm Cabling
Cable Parameter
|
Description
|
Interface:
|
Dry-contact relay closure
|
Wire:
|
24 AWG, shielded, 6-pair
|
Connector:
|
DB-15, Subminiature, male
|
Table 31-17 Network Alarm Pin Assignments
Pin
|
Alarm
|
Description
|
1
|
Audible—Major
|
Normally open
|
2
|
|
Common
|
9
|
|
Normally closed
|
4
|
Visual—Major
|
Normally open
|
5
|
|
Common
|
12
|
|
Normally closed
|
7
|
unused
|
n.c.
|
8
|
unused
|
n.c.
|
3
|
Audible—Minor
|
Normally open
|
11
|
|
Common
|
10
|
|
Normally closed
|
6
|
Visual—Minor
|
Normally open
|
14
|
|
Common
|
13
|
|
Normally closed
|
15
|
unused
|
n.c.
|
Standard BPX Switch Cables
Table 31-18 lists the various cables that may be ordered directly from Cisco.
Cable lengths are specified as a suffix to the Cisco model number. For example 5610-50 indicates a 50 foot cable. Cables are generally available in the following standard lengths:
•
10 ft (3 m)
•
25 ft (7.6 m)
•
50 ft (15 m)
•
75 ft (22.8 m)
•
100 ft (30 m)
Lengths of 101 ft. (30 m.) to 600 ft. (183 m.) are available on a special order.
When a cable is connectorized, the connector gender (male-female) is indicated as well as the number of pins. For example, RS-232/M25-M25 indicates a cable terminated with a male DB25 at both ends.
Table 31-18 Standard Cables Available from Cisco
Model#
|
Description
|
Usage
|
T3-E3-10 T3-E3-25 T3-E3-50 T3-E3-75 T3-E3-xx
|
75 W coax/BNC-BNC, 10' 75 W coax/BNC-BNC, 25' 75 W coax/BNC-BNC, 50' 75 W coax/BNC-BNC, 75' length to be specified
|
T3 or E3 trunk interface
|
5620
|
RS-232/M25-F25
|
Control port to control terminal or ext. window device
|
5621
|
RS-232/M25-M25 special
|
Control or Aux. port to modem
|
5623
|
RS-232/M25-M25
|
Aux. port to ext. window device
|
5601
|
Ground cable
|
DC
|
5670
|
Molex-pigtail
|
DC
|
5671
|
Spade lug-pigtail
|
DC
|
Redundancy "Y" Cable
The redundancy cables are a special "Y" cable available from Cisco. They are required for redundant trunk and data interfaces.
Table 31-19 lists the Y-cables used with various BPX switch back cards.
Table 31-19 Redundancy Y-Cables
Y - Cable
|
Used On
|
Cisco P/N
|
T3 trunk
|
LM-3T3
|
TBS
|
E3 trunk
|
LM-3E3
|
TBS
|
Aux./Cont. ports
|
LM-BCC
|
TBS
|
Ext. Clk. In
|
LM-BCC
|
TBS
|
Ext. Clk. Out
|
LM-BCC
|
TBS
|