Table of Contents
Technical Specifications
Hardware Specifications
Software Specifications
Technical Specifications
This appendix provides the technical specifications for the Cisco 6130 with NI-2 system. The appendix contains the following sections:
Hardware Specifications
This section details the specifications for the following hardware components:
- Cisco 6130 with NI-2 system
- Quad-port DMT ATU-C line card (4xDMT)
- Quad-port flexi ATU-C line card (4xflexi)
- Quad-port STU-C line card (4xSDSL)
- DS3/2DS3 NI-2 card
- OC-3c/OC-3c NI-2 card
Cisco 6130 with NI-2 System Specifications
Table A-1 lists the hardware specifications of the Cisco 6130 with NI-2 system.
Table A-1
Hardware Specifications
| Specification |
Description |
|
Dimensions
|
Cisco 6130
Cisco 6120
Fan tray
|
9 RUs123 in. x 15.75 in. x 12 in. (58.42 cm x 40.005 cm x 30.48 cm)
4 RUs23 in. x 7 in. x 12 in. (58.42 cm x 17.78 cm x 30.48 cm)
2 RUs23 in. x 3.5 in. x 12 in. (58.42 cm x 8.89 cm x 30.48 cm)
|
|
Weight
|
Cisco 6130
Cisco 6120
Fan tray
|
Emptyapproximately 31 lb (14.06 kg)
Loadedapproximately 62 lb (28.12 kg)
Emptyapproximately 16 lb (7.26 kg)
Loadedapproximately 34 lb (15.42 kg)
Loadedapproximately 18.45 lb (8.37 kg)
|
|
Network interface
|
ATM OC-3c (single- or multimode fiber), ATM DS3
|
|
ADSL interface
|
CAPUp to 7.168 Mbps downstream/1.088 Mbps upstream
DMTUp to 8.032 Mbps downstream/1024 kbps upstream
G.liteUp to 1.536 Mbps downstream/512 kbps upstream
|
|
SDSL interface
|
2B1Q encoding; up to 1168 kbps upstream and downstream
|
|
Craft interface
|
Console terminal connection on the NI-2 card
|
|
Management access
|
- RJ-45 interface for craft alarm discovery
- RJ-45 Ethernet
- ATM in-band management
|
|
External alarm contacts
|
Single dry contact alarm input (NO)
|
|
Power requirements
|
-48V DC
Note See "Preparing for Installation" for detailed power requirements.
|
|
CO operating requirements
|
Temperature
Altitude
Humidity
|
41 to 104ºF (5 to 40ºC)Operating
23 to 163ºF (-5 to 50ºC)Short term operating
-60 meters to 3200 meters
5 to 90% (noncondensing)
|
|
Subtending
|
NI-2 card
|
|
Redundancy
|
NI-2 card and APS2
|
| RU = rack unit. An RU is equal to 1.75 inches (4.45 cm).
APS = automatic protection switching.
|
4xDMT Specifications
Table A-3 lists the specifications for the 4xDMT.
Table A-2 4xDMT Specifications
| Specification |
Description |
|
Standards supported
|
ITU G.dmt
ITU G.lite
ANSI T1.413 Issue 2
|
|
External interfaces
|
4 (no connectors on card)
|
|
Data rates (per port)
|
Upstream: Up to 864 kbps
Downstream: Up to 8.032 Mbps
|
|
Internal hardware
|
- 18 MHz AM186ESLV.2 CPU
- AD20msp918 DMT modem chipset
- 128 KB SRAM
- 256K x 16 boot flash
- 2 kb serial EEPROM
|
|
Dimensions
|
Height: 6.07 in. (15.42 cm)
Depth: 8.50 in. (21.59 cm)
Width: 0.88 in. (2.24 cm)
|
|
Weight
|
0.875 lb (0.4 kg)
|
|
Power consumption
|
16.5W
|
|
Minimum software requirements
|
Cisco IOS Release 12.0(5)DA
CDM1Release 3.2 (optional)
|
4xflexi Specifications
Table A-3 lists the specifications for the 4xflexi.
Table A-3
4xflexi Specifications
| Specification |
DMT Mode |
CAP Mode |
G.lite Mode |
|
Standards supported
|
ITU G.dmt (G.992.1)
ANSI T1.413 Issue 2
|
RADSL1
|
ITU G.lite (G.992.2)
|
|
Power consumption
|
17.5W
|
13.5W
|
13.5W
|
|
Maximum data rates (per port)
Downstream
Upstream
|
8.032 Mbps
864 kbps
|
7.168 Mbps
1.088 Mbps
|
1.536 Mbps
512 kbps
|
|
External interfaces
|
4 (no connectors on card)
|
|
Internal hardware
|
AMD 186-based 3.3V 18-MHz CPU
128 KB SRAM
512K flash
|
|
Dimensions
|
Height: 6.07 in. (15.42 cm)
Depth: 8.50 in. (21.59 cm)
Width: 0.88 in. (2.24 cm)
|
|
Weight
|
0.875 lb (0.4 kg)
|
|
Minimum software requirements
|
Cisco IOS Release 12.1(2)DA
CDMRelease 3.2 (optional)
|
| Rate-adaptive digital subscriber line. |
4xSDSL Specifications
Table A-4 lists the specifications for the 4xSDSL.
Table A-4
4xSDSL Specifications
| Specification |
Description |
|
Standards supported
|
ITU G.991.1
|
|
External interfaces
|
4 (no connectors on card)
|
|
Maximum data rates (per port)
Downstream
Upstream
|
1168 kbps
1168 kbps
|
|
Line encoding
|
2B1Q
|
|
Internal hardware
|
AMD 186-based 3.3V 18-MHz CPU
128 KB SRAM
512K flash
|
|
Dimensions
|
Height: 6.07 in. (15.42 cm)
Depth: 8.50 in. (21.59 cm)
Width: 0.88 in. (2.24 cm)
|
|
Weight
|
0.875 lb (0.4 kg)
|
|
Power consumption
|
9W
|
|
Minimum software requirements
|
Cisco IOS Release 12.1(2)DA
CDMRelease 3.2 (optional)
|
DS3/2DS3 NI-2 Card Specifications
Table A-5 lists the specifications for the DS3/2DS3 NI-2 card.
Table A-5
DS3/2DS3 NI-2 Card Specifications
| Specification |
Description |
|
Internal hardware
|
150 MHz RC64475 CPU
Galileo GT64120 system controller
1M x 32 bootflash
4M x 32 Flash
512 KB boot EPROM
|
|
Dimensions
|
Height: 12.38 in. (31.45 cm)
Depth: 8.50 in. (21.59 cm)
Width: 1.80 in. (4.57 cm)
|
|
Weight
|
3.0 lb (1.36 kg)
|
|
Level 2 protocol
|
ATM
|
|
External interfaces
|
Three DS3 (44.736-Mbps) coaxial ports
|
|
Connector type
|
BNC1
|
|
Impedance
|
75 ohms (nominal)
|
|
Line encoding
|
B3ZS
|
|
Framing
|
C-bit parity, optionally PLCP with M23, otherwise Add Drop Multiplexer (ADM)
|
|
Power consumption
|
33.5W
|
|
Redundancy
|
NI-2 card redundancy only (with a second NI-2 card installed). No link redundancy.
|
|
Minimum software requirements
|
Cisco IOS Release 12.1(4)DA
CDM 3.2 (optional)
|
| The Bayonet-Neill-Concelman (BNC) connectors are located on the system I/O card which is installed on the backplane of the chassis. |
OC-3c/OC-3c NI-2 Card Specifications
Table A-6 lists the specifications of the single-mode and multimode versions of the OC-3c/OC-3c NI-2 card.
Table A-6
OC-3c/OC-3c NI-2 Card Specifications
| Specification |
Description |
|
Internal hardware
|
- 150 MHz RC64475 CPU
- Galileo GT64120 system controller
- 1M x 32 boot flash1 (4 MB)
- 4M x 32 Flash (16 MB)
- 512 KB boot EPROM
|
|
Dimensions
|
Height: 12.38 in. (31.45 cm)
Depth: 8.50 in. (21.59 cm)
Width: 1.80 in. (4.57 cm)
|
|
Weight
|
3.0 lb (1.36 kg)
|
|
Layer 2 protocol
|
ATM
|
|
Power consumption
|
33.5W
|
|
Minimum software and network management requirement
|
Cisco IOS
- Non-redundant NI-2 card configurationsRelease 12.1(1)DA
- Redundant NI-2 card configurationsRelease 12.1(7)DA
CDMRelease 3.0/3.2 (optional)
|
|
Single-Mode Card |
Multimode Card |
|
External interfaces
|
Two OC-3c/STM-1 (155 Mbps) single-mode ports
|
Two OC-3c/STM-1 (155 Mbps) multimode ports
|
|
Connector type
|
SC-PC
|
SC-PC
|
|
Fiber type
|
Intermediate reach single mode
|
Multimode
|
|
Average transmitted power
|
-15 to -8 dBm
|
-20 to -14 dBm
|
|
Average received power
|
-8 dBm
|
-11 dBm
|
|
Transmission distance
|
Up to 12 miles (19.3 km)
|
Up to 1.2 miles (1.93 km)
|
|
Wavelength
|
1310 nm
|
1300 nm
|
| The version of the OC-3c/OC-3c NI-2 card with enhanced upstream bandwidth features (NI2-155SM-155SM2 and NI2-155MM-155MM2) has a 2M x 32 bootflash (8 MB). |
Software Specifications
Table A-7 lists Cisco 6130 with NI-2 system software specifications.
Table A-7
Software Specifications
| Specification |
Description |
|
Management protocols
|
Cisco IOS software support for SNMP to CEMF1
|
|
Management applications
|
|
|
Management interfaces
|
In bandATM VC
Out of band10BaseT Ethernet, console, auxiliary
|
| CEMF = Cisco Element Management Framework |