Table of Contents
R2 Signaling Tones and Pulse Code Modulation Line Signaling
This chapter describes the R2 signaling tones generated and detected by the MFCR2 transceiver cards, and the R2 pulse code modulation (PCM) 2-bit line signaling transmitted and received by E1 spans.
Table 2-1 through Table 2-4 provide R2 signaling information based on ITU Q.441 as it applies specifically to the Guangdong telephone network.
 |
Note All R2 tones are -8.86 dBm per component. |
Table 2-1: R2 Signaling Group I Forward Signals
| Token Data Field |
Designation |
Frequencies |
Digit Meaning |
KA1 |
KC2 |
KE3 |
|
1
|
G-I-1
|
1380 + 1500 Hz
|
Digit 1
|
Regular
|
Not applicable
|
|
2
|
G-I-2
|
1380 + 1620 Hz
|
Digit 2
|
Immediate
Meter
|
|
3
|
G-I-3
|
1500 + 1620 Hz
|
Digit 3
|
Immediate Printer
|
|
4
|
G-I-4
|
1380 + 1740 Hz
|
Digit 4
|
Spare
|
|
5
|
G-I-5
|
1500 + 1740 Hz
|
Digit 5
|
Free
|
|
6
|
G-I-6
|
1620 + 1740 Hz
|
Digit 6
|
Spare
|
|
7
|
G-I-7
|
1380 + 1860 Hz
|
Digit 7
|
Spare
|
|
8
|
G-I-8
|
1500 + 1860 Hz
|
Digit 8
|
Priority
Regular
|
|
9
|
G-I-9
|
1620 + 1860 Hz
|
Digit 9
|
Spare
|
|
10
|
G-I-10
|
1740 + 1860 Hz
|
Digit 0
|
Priority
Free
|
|
11
|
G-I-11
|
1380 + 1980 Hz
|
Not applicable
|
Spare
|
Spare
|
H
|
|
12
|
G-I-12
|
1500 + 1980 Hz
|
Spare
|
ATME
|
Spare
|
|
13
|
G-I-13
|
1620 + 1980 Hz
|
Not applicable
|
Test
|
T
|
T
|
|
14
|
G-I-14
|
1749 + 1980 Hz
|
Spare
|
Priority
|
Spare
|
|
15
|
G-I-15
|
1860 + 1980 Hz
|
End of
Number
|
Spare
|
Satellite
|
Not applicable
|
1Calling party category.
2Call category used between toll exchanges; used to indicate a priority call or a test call.
3Call category from toll to local, or from local to local; used to indicate a test call.
|
Table 2-2: R2 Signaling Group II (KD) Forward Signals
| Token Data Field |
Designation |
Frequencies |
Meaning |
|
1
|
G-II-1
|
1380 + 1500 Hz
|
Semiautomatic toll operators call
|
|
2
|
G-II-2
|
1380 + 1620 Hz
|
Toll automatic call
|
|
3
|
G-II-3
|
1500 + 1620 Hz
|
Local call
|
|
4
|
G-II-4
|
1380 + 1740 Hz
|
Local priority call
|
|
5
|
G-II-5
|
1500 + 1740 Hz
|
Operators check the calling party's number in SA call
|
|
6
|
G-II-6
|
1620 + 1740 Hz
|
Test call
|
|
7
|
G-II-7
|
1380 + 1860 Hz
|
Not applicable
|
|
8
|
G-II-8
|
1500 + 1860 Hz
|
|
9
|
G-II-9
|
1620 + 1860 Hz
|
|
10
|
G-II-10
|
1740 + 1860 Hz
|
|
11
|
G-II-11
|
1380 + 1980 Hz
|
|
12
|
G-II-12
|
1500 + 1980 Hz
|
|
13
|
G-II-13
|
1620 + 1980 Hz
|
|
14
|
G-II-14
|
1740 + 1980 Hz
|
Not applicable
|
|
15
|
G-II-15
|
1860 + 1980 Hz
|
Table 2-3: R2 Signaling Group A Backward Signals
| Token Data Field |
Designation |
Frequencies |
Meaning |
|
1
|
A-1
|
1140 + 1020 Hz
|
Send next digit (n+1)
|
|
2
|
A-2
|
1140 + 900 Hz
|
Start from first digit
|
|
3
|
A-3
|
1020 + 900 Hz
|
Number complete, change over to reception of Group-B signals
|
|
4
|
A-4
|
1140 + 780 Hz
|
Network congestion
|
|
5
|
A-5
|
1020 + 780 Hz
|
Vacant number
|
|
6
|
A-6
|
900 + 780 Hz
|
Send KA and calling party's number1
|
|
7
|
A-7
|
1140 + 660 Hz
|
Not applicable
|
|
8
|
A-8
|
1020 + 660 Hz
|
|
9
|
A-9
|
900 + 660 Hz
|
|
10
|
A-10
|
780 + 660 Hz
|
|
11
|
A-11
|
1140 + 540 Hz
|
|
12
|
A-12
|
1020 + 540 Hz
|
|
13
|
A-13
|
900 + 540 Hz
|
|
14
|
A-14
|
780 + 540 Hz
|
|
15
|
A-15
|
660 + 540 Hz
|
1First A-6 is an instruction to send KA signal. Successive A-1s are to send the calling party identity as G-I signals.
|
Table 2-4: R2 Signaling Group B (KB) Backward Signals
| Token Data Field |
Designation |
Frequencies |
When KD=1, 2, or 6 |
When KD = 3 or 4 |
|
1
|
B-1
|
1140 + 1020 Hz
|
Idle
|
Idle
|
|
2
|
B-2
|
1140 + 900 Hz
|
Busy, local duty
|
Spare, using called party control or first party control
|
|
3
|
B-3
|
1020 + 900 Hz
|
Busy, toll duty
|
Spare
|
|
4
|
B-4
|
1140 + 780 Hz
|
Congestion
|
Called subscriber busy or equipment congestion
|
|
5
|
B-5
|
1020 + 780 Hz
|
Vacant number
|
Vacant number
|
|
6
|
B-6
|
900 + 780 Hz
|
Spare
|
Called subscriber idle using calling party control
|
|
7
|
B-7
|
1140 + 660 Hz
|
Not applicable
|
Not applicable
|
|
8
|
B-8
|
1020 + 660 Hz
|
|
9
|
B-9
|
900 + 660 Hz
|
|
10
|
B-10
|
780 + 660 Hz
|
|
11
|
B-11
|
1140 + 540 Hz
|
|
12
|
B-12
|
1020 + 540 Hz
|
|
13
|
B-13
|
900 + 540 Hz
|
|
14
|
B-14
|
780 + 540 Hz
|
|
15
|
B-15
|
660 + 540 Hz
|
Table 2-5 describes the 2-bit, channel-associated pulse code modulation (PCM) line signaling used by VCO/4K systems equipped with E1 interface cards. This digital R2 signaling complies with Shenzhen Specification NTP-8445, May 1990, Appendix D. Forward signals are used by originating or outgoing ports, while backward signals are generated by incoming ports. For more information on E1 cards, refer to the Cisco VCO/4K Card Technical Descriptions manual.
Table 2-5: R2 Pulse Code Modulation Line Signaling
| Signal |
Exchange Signaling Forward Backward |
|
Af Bf |
Ab Bb |
|
Idle
|
1 0
|
1 0
|
|
Seize
|
0 0
|
1 0
|
|
Seize Acknowledge
|
0 0
|
1 1
|
|
Answer
|
0 0
|
0 1
|
|
Flash
(for 600 ms)
|
1 0
|
0 1
|
|
Called Party Clear
|
0 0
|
1 1
|
|
Called Party Re-answer
(before time-out)
|
0 0
|
0 1
|
|
Calling Party Clear
(before called party)
|
1 0
|
0 1
|
|
Calling Party Clear
(after called party)
|
1 0
|
1 1
|
|
Release Guard
|
1 0
|
1 0
|
|
Blocking
|
1 0
|
1 1
|