ATM Port Adapter Installation Guide
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Carrier Module and Port Adapter Specifications
![]() |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Table of ContentsCarrier Module andPort Adapter Specifications System Specifications
Port Adapter Specifications and Part Numbers Maximum Station-to-Station Cabling Distances Fiber-Optic Power Levels Standards Compliance Carrier Module and
|
| Description | Specifications |
|---|---|
|
Dimensions (H x W x D) |
Carrier module: 1.2 x 14.4 x 16" (3.0 x 36.6 x 40.6 cm) Port adapter: 1.2 x 6.5 x 10" (3.0 x 16.5 x 25.4 cm) |
|
Weight |
Carrier module: 3.55 lb (1.60 kg) Port adapter (approximately): 1.10 lb (0.50 kg) |
|
DC voltages supplied and steady-state maximum current ratings |
+12V @ 2A +24V @ 0.2A |
|
Operating temperature |
32 to104ºF (0 to 40ºC) |
|
Nonoperating temperature |
-40 to 167ºF (-40 to 75ºC) |
|
10 to 90%, noncondensing |
|
|
Altitude |
-500 to 10,000 ft (-52 to 3,048 m) |
|
Interface timing |
Loop timing, Stratum 4 accuracy clock for self-timing; synchronous, SRTS3, or adaptive clocking for CBR4 traffic |
|
Carrier module |
Carrier module for 2-port adapters with slot covers for empty slots installed (WATM-CAM-2P=) |
|
Dimensions (H x W x D) |
Carrier module: 1.2 x 14.4 x 16" (3.0 x 36.6 x 40.6 cm) Port adapter: 1.2 x 6.5 x 10" (3.0 x 16.5 x 25.4 cm) |
| 1V = volts. 2A = amperes. 3SRTS = Synchronous Residual Time Stamp. 4CBR = constant bit rate. |
Port adapter specifications, including number of ports, connector types, and part numbers are listed in Table A-2.
| Port Adapter | Number and Type of Ports |
Connectors | Part Number |
|---|---|---|---|
|
155-Mbps port adapter |
4 SONET STS-3c/SDH STM-1 multimode fiber ports |
SC connectors |
WAI-OC-3-4MM |
|
4 SONET STS-c/SDH STM-1 single-mode fiber ports1 |
SC connectors |
WAI-OC-3-4SM |
|
|
4 SONET STS-3c/SDH ST-1: |
SC connectors |
WAI-OC3-1S3M |
|
|
4 SONET ST-3c/SDH ST-1 UTP-5 ports |
RJ-45 connectors |
WAI-C3-4U5 |
|
|
622-Mbps port adapter |
1 SONET ST-12c/SDH STM-4c single-mode fiber port2 |
SC connector |
WAI-OC12-1SM |
|
1 SONET STS-12c/SDH STM-4c multimode fiber port |
SC connector |
WAI-OC12-1MM |
|
|
DS3 and E3 port adapters |
2 DS3 ports |
WAI-T3-2BNC |
|
|
4 DS3 ports |
BNC connectors |
WAI-T3-4BNC |
|
|
2 E3 ports |
BNC connectors |
WAI-E3-2BNC |
|
|
4 E3 ports |
BNC connectors |
WAI-E3-4BNC |
|
|
25-Mbps port adapter |
12 25-Mbps ports |
RJ-45 connectors |
WAI-ATM25-12P |
|
T1 and E1 port adapters |
4 E1 trunk ports |
RJ-48 connectors |
WAI-E1-4RJ48 |
|
4 T1 trunk ports |
RJ-48 connectors |
WAI-T1-4RJ48 |
|
|
4 E1 trunk ports |
BNC connectors |
WAI-E1-4BNC |
|
|
CES T1 and E1 port adapters |
4 E1 CES ports |
BNC connectors |
WAI-E1C-4BNC |
|
4 E1 CES ports |
RJ-48 connectors |
WAI-E1C-4RJ48 |
|
|
4 T1 CES ports |
RJ-48 connectors |
WAI-T1C-4RJ48 |
|
|
CE1 Frame Relay |
4 CE1 ports |
RJ-48c connectors |
C85MS-4E1-FRRJ48 |
|
4 CE1 ports (spare) |
RJ-48c connectors |
C85MS-4E1-FRRJ48= |
| 1Available in intermediate- and long-reach fiber. 2Available in intermediate- and long-reach fiber. |
Maximum station-to-station cabling distances and cable types are listed for each port adapter in Table A-3.
| Port Adapter | Cable | Cabling Distance |
|---|---|---|
|
DS3 |
Coaxial cable |
450 ft (137 m) |
|
E3 |
Coaxial cable |
450 ft (137 m) |
|
OC-3 |
UTP1 cable |
328 ft (100 m) |
|
OC-3 and OC-12 |
9/125 micron single-mode fiber |
9 miles (15 km) |
|
OC-3 and OC-12 |
9/125 micron single-mode long-reach fiber |
18 miles (30 km) |
|
OC-3 |
50/125-micron and 62.5/125-micron multimode fiber |
1.24 miles (2 km) |
|
OC-12 |
50/125-micron and 62.5/125-micron multimode fiber |
1640 ft (500 m) |
|
T1 |
UTP cable |
650 ft (198 m) |
|
E1 |
UTP cable |
650 ft (198 m) |
|
E1 |
Coaxial cable |
650 ft (198 m) |
|
CE1 Frame Relay |
Category 5 twisted-pair |
650 ft (198 m) |
|
CES T1 |
Twisted-pair and STP2 |
820 ft (248.5 m) |
|
CES E1 |
Twisted-pair and STP |
820 ft (248.5 m) |
|
CES E1 |
Coaxial cable |
650 ft (198 m) |
|
25-Mbps |
UTP cable |
328 ft (100 m) with four or fewer separate cable segments on the path |
| 1UTP = unshielded twisted-pair. 2STP = shielded twisted-pair. 3AWG = American Wire Gauge. 4RJ = Registered Jack. |
Fiber-optic power levels are listed for each port adapter in Table A-4.
| Port | Output Center Wavelength | Transmit | Receive |
|---|---|---|---|
|
OC-3 single mode |
1261 to 1360 nm1 |
Minimum: -15.0 dBm2 Maximum: -8.0 dBm |
Minimum: -28.0 dBm Maximum: -8.0 dBm |
|
OC-3 Single-Mode Long Reach |
1281 to 1380 nm |
Minimum: -5.0 dBm Maximum: 0.0 dBm |
Minimum: -34.0 dBm Maximum: -10.0 dBm |
|
OC-3 Multimode |
1270 to 1380 nm |
Minimum: -20.0 dBm Maximum: -14.0 dBm |
Minimum: -30.0 dBm Maximum: -14.0 dBm |
|
OC-12 Single-Mode Extended Reach |
1274 to 1356 nm |
Minimum: -15.0 dBm Maximum: -8.0 dBm |
Minimum: -28.0 dBm Maximum: -8.0 dBm |
|
OC-12 Multimode |
1270 to 1380 nm |
Minimum: -20.0 dBm Maximum: -14.0 dBm |
Minimum: -26.0 dBm Maximum: -14.0 dBm |
|
OC-12 Single-Mode Long Reach |
1280 to 1335 nm |
Minimum: -3.0 dBm Maximum: 2.0 dBm |
Minimum: -28.0 dBm Maximum: -8.0 dBm |
| 1nm = nanometers. 2dBm = decibel milliwatt. |
Catalyst 8540/8510/5500 and LightStream 1010 port adapters, when installed in a system, comply with the standards listed in Table A-5.
| Specification | Standard | Description |
|---|---|---|
|
Compliance |
CE Marking |
Cisco Systems |
|
Safety |
UL 1950 (U.S.) |
Underwriters Laboratory |
|
CSA 950 (Canada) |
Canadian Standards Association |
|
|
EN 60950 (European Union) |
European Norm. |
|
|
TUV GS (Germany) |
German Test Agency |
|
|
IEC 950 (International) |
International Electrotechnical Commission |
|
|
AS/NZS 3260 (Australia/New Zealand) |
Australia/New Zealand Standards |
|
|
Electromagnetic Interference (EMI) |
FCC Part 15 (CFR 47) Class A |
Federal Communications Commission |
|
EN55022 |
European Norm. |
|
|
VCCI |
Voluntary Control Council for Interference |
|
|
AS/NZS 3548 |
Australia/New Zealand Standards |
|
|
CISPR 22 |
Comite International Special Des Perturbations Radioelectriques |