This appendix provides information on the Cisco DVB Interactive Network Adapter INA2320 specifications.
Table A-1 lists the Cisco DVB INA2320 physical and electrical specifications and power requirements.
|
| Description |
Specifications |
| Downstream communication |
|
|
Channel bandwidth
|
In-Band 8 MHz
Out-of-Band 1 or 2 MHz
|
|
Modulation scheme
|
QPSK (QAM4), QAM 16/32/64/128 software-configured
|
|
Roll-off factor alpha
|
In-Band: 0.15
Out-of-Band: 0.181
|
|
Carrier/noise ratio
|
INA2320 > 43 dB
DVX167/DAVIC 1.2: > 43 dB2
|
|
Framing IB
|
MPEG, DSM-CC MPE, Direct IP or LLC/SNAP
|
|
Framing OOB
|
SL-ESF, AAL5, Direct IP
|
|
ASI output
|
BNC connector, 75 Ohm
|
| RF Output |
|
|
RF Output level
|
VHF: 101-111 dBmicroV
UHF: 100-110 dBmicroV
|
|
Frequency range
|
VHF: 9.5-466.5 MHz
UHF: 472.75 - 858.75 MHz
|
|
Physical interface
|
Tx output connector BNC, 75 Ohm
|
|
IF amplifier output test point
|
-20 dB ± 1 dB
|
|
Upconverter gain adjustment
|
VHF: 11 dB
UHF: 10 dB
|
| Upstream communication |
|
|
Channel bandwidth
|
Selectable:
1 MHz, 1.544 Mbps at input level 58 - 75 dBµV
2 MHz, 3.088 Mbps at input level 58 - 75 dBµV
|
|
Roll-off factor alpha
|
0.253
|
|
Input frequency range
|
5-65 MHz (in 10 kHz resolution)
|
|
Framing
|
AAL5 (ATM)
|
|
Physical interface
|
Rx Input connector BNC, 75 Ohm
|
| Alarm |
|
|
Alarm connector
|
9-pin sub-D male
|
| Interfaces |
|
|
Ethernet Interfaces
|
RJ-45 10/100
|
| Power |
|
|
Supply
|
100-250 V AC
|
|
Power consumption
|
80 W max.
|
| EMC and Safety |
|
|
Immunity
|
EN 61000-4-3 Radiated Electric Field Immunity
EN 61000-4-2 Electrostatic Discharge
EN 61000-4-4 Electrical Fast Transients (Burst) AC Line
EN 61000-4-4 Electrical Fast Transients (Burst) Signal Line
EN 61000-4-11 Voltage Dips
EN 61000-4-11 Voltage Interruption
EN 61000-4-6 Injected RF
EN 61000-4-5 Surges AC Line
EN 61000-4-5 Surges Indoor Signal Line
|
|
Emission,
Radiated Emission4
|
EN 55022, 1998
CISPR 22, 1997
EN 300386-2, 1997
ETS 300386-1, AS/NZ3548, 1995
VCCI: V-3/97.04
47CFR15:1997
|
|
Emission,
Conducted Emission
AC Line5
|
EN 55022, 1998
CISPR 22, 1997
EN 300386-2, 1997
ETS 300386-1, AS/NZ3548, 1995
VCCI: V-3/97.04
47CFR15:1997
|
|
Safety
|
EN 60950
|
| Dimensions and weight |
|
|
19" standard subrack
|
|
|
Dimensions (H x W x D)
|
13.2 x 45 x 24.5 cm (5.2 x 17.7 x 9.7 in.)
|
|
Weight
|
9.4 kg (20.72 lbs)
|
| Environmental |
|
|
Temperature
|
0 to 40 C (32 to 104 F) operating; -20 to 65 C (-4 to 149 F) non-operating
|
|
Humidity
|
10 to 90% non-condensing
|