IMPORTANT:
IMPORTANT:
IMPORTANT:
IMPORTANT:
CAUTION:
Verifying System Startup
Checking PFU Status
Checking Status LEDs on MIOs
| Label | LED Color | LED State | Notes |
|---|---|---|---|
| Card Transition | |||
| Run/Fail | Green | Blink | Card is booting, starting or initializing. |
| Active | — | OFF | |
| Redundant | — | OFF | |
| Master | — | OFF | |
| Busy | — | OFF | |
| Card Active – Master (Normal) | |||
| Run/Fail | Green | ON |
Card is backed up
by other MIO/UMIO.
All ports are backed
up by other MIO/UMIO.
|
| Active | Green | ON | |
| Redundant | Green | ON | |
| Master | Green | ON | |
| Busy | — | OFF | |
| Card Active – Master | |||
| Run/Fail | Green | ON |
Card is not backed up
by other MIO/UMIO.
Port may not be backed
up by other MIO/UMIO.
|
| Active | Green | ON | |
| Redundant | Amber | ON | |
| Master | Green | ON | |
| Busy | — | OFF | |
| Card Active – Standby (Normal) | |||
| Run/Fail | Green | ON |
Card is online and
functioning as a Slave.
Any port can be active.
All ports are backed
up by other MIO/UMIO.
|
| Active | — | OFF | |
| Redundant | Green | ON | |
| Master | — | OFF | |
| Busy | — | OFF | |
| Card Active – Secondary (Normal) | |||
| Run/Fail | Green | ON |
Card is online and
functioning as a Slave.
Any port can be active.
All ports are backed
up by other MIO/UMIO.
|
| Active | Green | ON | |
| Redundant | Green | ON | |
| Master | — | OFF | |
| Busy | — | OFF | |
| Card Active – Secondary | |||
| Run/Fail | Green | ON |
Card is online and
functioning as a Slave.
Any port can be active.
Any port may not be
backed up by other MIO/UMIO.
|
| Active | Green | ON | |
| Redundant | Amber | ON | |
| Master | — | OFF | |
| Busy | — | OFF | |
| Card Switchover | |||
| Run/Fail | Green | ON | Card is online; switchover to or from other MIO/UMIO is in progress. |
| Active | Green | Blink | |
| Redundant | Amber | Blink | |
| Master | Green | Blink | |
| Busy | — | OFF | |
| Card Failed | |||
| Run/Fail | Red | ON | Card has failed and is offline. |
| Active | — | OFF | |
| Redundant | — | OFF | |
| Master | — | OFF | |
| Busy | — | OFF | |
| Card Offline | |||
| Run/Fail | — | OFF | Card is offline. |
| Active | — | OFF | |
| Redundant | — | OFF | |
| Master | — | OFF | |
| Busy | — | OFF | |
| Port Status | |||
| Port – Link | Green | ON | Port is in active mode. |
| Amber | ON | Port is in standby mode. | |
| — | OFF | Port is down. | |
| Port Activity | Green | Blink | Data is being sent/received. |
| — | OFF | Data is not being sent/received. | |
Checking Status LEDs on Data Processing Cards
| Label | LED Color | LED State | Notes |
|---|---|---|---|
| Card Transition | |||
| Run/Fail | Green | Blink | Card is booting, starting or initializing. |
| Active | — | OFF | |
| Redundant | — | OFF | |
| Card Active (Normal) | |||
| Run/Fail | Green | ON | Card is backed up by other DPC/UDPC. |
| Active | Green | ON | |
| Redundant | Green | ON | |
| Card Active | |||
| Run/Fail | Green | ON | Card is not backed up by other DPC/UDPC. |
| Active | Green | ON | |
| Redundant | Amber | ON | |
| Card Standby (Normal) | |||
| Run/Fail | Green | ON | Card is online and in standby mode. |
| Active | — | OFF | |
| Redundant | Green | ON | |
| Card Migrate | |||
| Run/Fail | Green | ON | Card is online and migrating from or to other DPC/UDPC. |
| Active | Green | Blink | |
| Redundant | Amber | ON | |
| Card Failed | |||
| Run/Fail | Red | ON | Card has failed and is offline. |
| Active | — | OFF | |
| Redundant | — | OFF | |
| Card Offline | |||
| Run/Fail | — | OFF | Card is offline. |
| Active | — | OFF | |
| Redundant | — | OFF | |
Checking Status LEDs on FSCs
| Label | LED Color | LED State | Notes |
|---|---|---|---|
| Card Transition | |||
| Run/Fail | Green | Blink | Card is booting, starting or initializing. |
| Active | — | OFF | |
| Redundant | — | OFF | |
| Drive 1 Active | — | OFF | SSD 1 is idle. |
| Drive 2 Active | — | OFF | SSD 2 is idle. |
| Card Active (Normal) | |||
| Run/Fail | Green | ON |
Redundant switch fabric
Redundant storage
|
| Active | Green | ON | |
| Redundant | Green | ON | |
| Drive 1 Active | Green | Blink | SSD 1 is being accessed. |
| Drive 2 Active | Green | Blink | SSD 2 is being accessed. |
| Card Active | |||
| Run/Fail | Green | ON |
Non-redundant
switch fabric
Non-redundant
storage
|
| Active | Green | ON | |
| Redundant | Amber | ON | |
| Drive 1 Active | Green | Blink | SSD 1 is being accessed. |
| Drive 2 Active | Green | Blink | SSD 2 is being accessed. |
| Card Failed | |||
| Run/Fail | Red | ON | Card has failed and is offline. |
| Active | — | OFF | |
| Redundant | — | OFF | |
| Drive 1 Active | — | OFF | SSD 1 is idle. |
| Drive 2 Active | — | OFF | SSD 2 is idle. |
| Card Offline | |||
| Run/Fail | — | OFF | Card is offline. |
| Active | — | OFF | |
| Redundant | — | OFF | |
| Drive 1 Active | — | OFF | SSD 1 is idle. |
| Drive 2 Active | — | OFF | SSD 2 is idle. |
Checking Status LEDs on SSC
| Label | LED Color | LED State | Notes |
|---|---|---|---|
| Card Transition | |||
| Run/Fail | Green | Blink | Card is booting, starting or initializing. |
| Active | — | OFF | |
| Redundant | — | OFF | |
| Card Active (Normal) | |||
| Run/Fail | Green | ON | Card is backed up by other SSC. |
| Active | Green | ON | |
| Redundant | Green | ON | |
| Card Active | |||
| Run/Fail | Green | ON | Card is not backed up by other SSC. |
| Active | Green | ON | |
| Redundant | Amber | ON | |
| Card Failed | |||
| Run/Fail | Red | ON | Card has failed and is offline. |
| Active | — | OFF | |
| Redundant | — | OFF | |
| Card Offline | |||
| Run/Fail | — | OFF | Card is offline. |
| Active | — | OFF | |
| Redundant | — | OFF | |
| System Indicators | |||
| Normal | |||
| System Status | Green | ON | System is in service. |
| System Service | — | OFF | There are no failed components. |
| Failed Components | |||
| System Status | Green | ON | System is in service. |
| System Service | Amber | ON | There are failed components. |
| Service Loss and Failed Components | |||
| System Status | Red | ON | System is out of service. |
| System Service | Amber | ON | There are failed components. |
| Service Loss with No Failed Components | |||
| System Status | Red | ON | System is out of service. |
| System Service | — | OFF | There are no failed components. |
| Offline or Transitioning | |||
| System Status | — | OFF | SSC is offline. |
| System Service | — | OFF | |