ASR 5500 Hardware Platform Overview

This chapter describes the hardware components that comprise the ASR 5500 chassis. The ASR 5500 is designed to provide subscriber management services for high-capacity 4G wireless networks.

This chapter includes the following sections:

Figure 1. The ASR5500

Chassis

The ASR 5500 is a 21RU, 19" rack-mount midplane-based chassis with input/output (I/O) and processing cards in the rear, and fabric cards in the front. Two ASR 5500 chassis fit into 42RU of rack space. However, the typical deployment will be a single chassis per rack with other equipment in the same rack.

The rear cards are larger and used for chassis management, I/O and session processing. The smaller front cards are used for fabric crossbars and persistent storage. There are 10 slots at the front and rear of the chassis.

The rear slots have a common midplane connector that is shared between the supported cards. This allows for different mixes of I/O and processing capacity depending on the customer's intended use.

The chassis can be flush-mounted or mid-mounted in a rack or equipment cabinet.


Figure 2. Front and Rear Views of the ASR 5500 Chassis

Power

The chassis accepts up to eight 80-amp, -48 VDC power feeds across redundant power filter units (PFUs). The connections are made at the top-rear of the chassis. The front-mounted PFUs incorporate separate circuit breakers for each power feed.

Cooling

The ASR 5500 uses two types of fan tray units and a total of four fan trays per chassis – two front fan trays and two rear fan trays. Air is drawn from the front and sides of the chassis and exhausted out the top rear and sides. Two fan trays are mounted at the bottom of the chassis with another two at the top. The bottom fan trays incorporate replaceable particulate air filters.

Slot Numbering

The rear slots are numbered 1 through 10 with slots 5 and 6 used for the chassis management cards. The front slots are numbered 11 through 20. Lower slot numbers begin at the left side. There are no direct relationships between front and rear cards.

The figure below shows the slot numbering sequence and the general layout of other components in the ASR 5500 chassis.


Figure 3. ASR 5500 Slot Numbering

Power Filter Units (PFUs)

Two PFUs mount at the top front of the chassis. Each PFU supports four power planes.

A total of eight -48 VDC, 80-amp power feeds are required for a full chassis. The eight feeds operate in a 4+4 redundant configuration. In lab environments where power redundancy is not required, four 80 A lines can be used.

Cable Management System

The ASR 5500 cable management system consists of two components. The first is a tray that mounts at the rear of the chassis immediately below the card cage. The second is a cable management bracket that mounts to the front panel of each Management Input/Output (MIO) or Management Input/Output Universal (UMIO) card.

Network cables are fed from either side or both sides of the tray and are then routed to the MIO/UMIO ports. The cables are secured to the cable management brackets on the MIO/UMIOs via cable ties or hook-and-loop straps, and within the cable management tray via hook-and-loop straps.

Midplane

The midplane within the ASR 5500 chassis interconnects rear input/output ports and processing cards with front fabric cards. The larger rear cards support chassis management, input/output, and session processing. The smaller front cards provide fabric crossbars, persistent storage and system status monitoring.

The rear slots have a common midplane connector that is shared between the supported cards. This allows for different mixes of input/output and processing capacity depending on the customer's intended use. The two MIO or UMIO slots (5 and 6) have additional midplane connections to perform chassis control operations, including support for a serial Console port and dual remote management ports.


Figure 4. ASR 5500 Midplane Buses

Card Types

The ASR 5500 supports rear cards and front cards. Rear cards are larger and perform node management, packet processing and I/O functions (traffic sources). Front cards determine the amount of bandwidth for the switching fabric (crossbars), and indicate the operating and alarm status of the ASR 5500. The figure below is a simplified block diagram showing the ASR 5500 card architecture.


Figure 5. Block Diagram of Card Architecture

Figure 6. ASR 5500 Card Types
1

[LF] Management I/O (MIO)

[RT] Management I/O Universal (UMIO)

2

[LF] Data Processing Card (DPC)

3

[LF] Data Processing Card 2 (DPC2)

[RT] Data Processing Card Universal 2 (UDPC2)

4 Fabric and Storage Card (FSC)
5 System Status Card (SSC) [LF] = Left image, [RT] = Right image


Rear Cards

The ASR 5500 supports several types of rear-mounted cards:

The ARS 5500 supports ten rear cards. Each card is interconnected with the others via the switching fabric.

IMPORTANT:

UMIO cards, UDPCs and UDPC2s are direct replacements for MIO cards and DPC/DPC2s. However, a special Universal PID license must be purchased and installed on the chassis for each installed UMIO and UDPC/UDPC2. Contact your Cisco account representative for additional information.

Management I/O

The ASR 5500 chassis supports two MIO /UMIO cards placed in the rear facing slots of the chassis. These cards perform chassis management, as well as local context and non-local context external I/O operations.

IMPORTANT:

The MIO/UMIO cards automatically implement 1:1 port redundancy (active/standby). Ports are 1:1 redundant across slots 5 and 6. For example, port 10 on the MIO in slot 5 is redundant with port 10 on the MIO in slot 6.

Each MIO/UMIO has:
  • One CPU subsystem with 96 GB of RAM
  • Four NPU subsystems
The two 1000Base-T (1GbE) ports on MIO/UMIO cards can only be used for local context (OAM). An MIO/UMIO includes support for:
  • Midplane connections for chassis control operations
  • SAS storage controller for FSC solid state drives (SSDs)
  • RS-232 serial console (RJ45) for CLI management
  • USB port for an external flash device
  • 32 GB SDHC internal flash device

MIO/UMIO cards support two daughter card (DCs) for external I/O interfaces (100 Gbps aggregate per DC). The optical ports on the daughter cards can only be used for non-local context. The currently available DC supports ten 10 GbE interfaces. The interface ports accept SFP+ SR and LR transceivers.

IMPORTANT:

MIO/UMIO daughter cards are not user installable or replaceable.

IMPORTANT:

MIO/UMIO cards are shipped with SFP+ SR or LR transceivers installed.

Data Processing Card

The ASR 5500 chassis supports multiple DPCs and/or UDPCs in the rear facing slots of the chassis.

The DPC/UDPC has two identical CPU subsystems with each containing:
  • Two six-core processors for a total of 24 cores per card
  • 96 GB of RAM
  • NPU for session data flow offload
  • Crypto offload engines located on a daughter card

DPC/UDPCs manage subscriber sessions and control traffic.

Front Cards

The ASR 5500 supports two types of front-mounted cards:

The crossbars that comprise the switching fabric are on the FSCs. The ASR 5500 supports multiple FSCs. Each FSC provides six physical fabric planes. When fully populated, there are 24 fabric planes in the system. A physical fabric plane provides full-mesh connectivity between all traffic sources.

Fabric and Storage Card (FSC)

The ASR 5500 chassis supports multiple FSCs in front facing slots of the chassis.

The FSC features:
  • Fabric cross-bars providing in aggregate:
    • 120 Gbps full-duplex fabric connection to each MIO/UMIO
    • 60 Gbps full-duplex fabric connection to each DPC/UDPC
  • Two 2.5" serial attached SCSI (SAS), 200GB solid state drives (SSDs) with a 6 Gbps SAS connection to each MIO/UMIO.

Every FSC adds to the available fabric bandwidth to each card. Each FSC connects to all MIO/UMIOs and data processing cards, with a varying number of links depending on the MIO/UMIO or data processing card slot. Three FSCs provide sufficient bandwidth while the fourth FSC supports redundancy.

IMPORTANT:

Although four FSCs are required for redundancy, the system can operate with three FSCs in the presence of a fourth failed FSC. Four FSCs must be installed for normal operation.

The ASR 5500 uses an array of solid state drives (SSDs) for short-term persistent storage. The RAID 05 configuration has each pair of drives on an FSC striped into a RAID 0 array; all the arrays are then grouped into a RAID 5 array. Each FSC provides the storage for one quarter of the RAID 5 array. Data is striped across all four FSCs with each FSC providing parity data for the other three FSCs. The array is managed by the master MIO/UMIO.

IMPORTANT:

The SSDs are not field replaceable units (FRUs). If an SSD fails the FSC must be replaced.

IMPORTANT:

A minimum of three FSCs must be online at all times for the array to operate. When an FSC is removed, one RAID 0 array is lost with the RAID 5 array providing redundancy.

IMPORTANT:

Removal of an FSC while the array is degraded or rebuilding may result in data loss.

The array appears under /hd-raid and is available to all data processing cards and MIO/UMIOs.

System Status Card (SSC)

The ASR 5500 chassis supports two SSCs in front facing slots of the chassis. SSCs use dedicated slots in the left most slots of the front side of the chassis.

The SSC card features:
  • Three alarm relays (Form C contacts)
  • Audible alarm with front panel Alarm Cutoff (ACO)
  • System status LEDs

LED Indicators

All ASR 5500 circuit cards incorporate light emitting diode (LED) status indicators. A base group appears on all cards. Card-specific indicators show the status of ancillary functions.

LED Indicators Common to All Cards


Table 1. Base LED Group
Label State Meaning
Run/Fail Off Offline
Green – Blink Transitioning
Green – Solid Online
Red Failure
Active Off Not applicable
Green – Blink Transitioning
Green – Solid Active
Redundancy Off Not applicable
Amber – Solid Non-redundant
Amber – Blink Transitioning
Green Redundant


LED Indicators on Specific Cards


Table 2. Card-specific LED Group
Label State Meaning
MIO or UMIO
Master Off Not applicable
Green – Blink Transitioning
Green – Solid Master
Busy Off No activity
Green Storage activity
Interface Ports
  Link Off No link with network
Amber – Blink Transitioning
Green – Solid Linked with network
  Activity Off No activity
Green – Blink Data exchange
FSC
Drive 1 Activity Off No activity
Green Activity
Drive 2 Activity Off No activity
Green Activity
SSC
System Status Off System offline
Green System online
Red Service loss
System Service Off System OK
Amber Failed component