MIO Port Cabling

This chapter describes how to cable the interface ports on Management I/O (MIO) or Management I/O Universal (UMIO) cards.

It includes the following sections:

Interface Ports

The interface ports are selectively enabled based on their functions in the system – management versus non-management.

Card Ports

MIO or UMIO cards in slot 5 and slot 6 of the ASR 5500 chassis support the following twisted-pair copper interface ports:
  • one serial Console port (RJ45)
  • two 1 Gigabit Ethernet ports (RJ45)

Daughter Card Ports

MIO or UMIO daughter cards support ten 10 Gigabit Ethernet ports each. The 10 GbE ports connect to other network devices via fiber optic cables that terminate on SFP+ transceivers.

Cable Management System

If you have equipped your ASR 5500 chassis and MIO or UMIO cards with the Cable Management System, refer to the Routing and Securing Network Cables section of the Cable Management System Installation appendix for additional information.


Figure 1. MIO or UMIO Ports
1 Console port 2 USB port
3 10 GbE ports, DC-1 4 10 GbE ports, DC-2
5 1 GbE ports (1000Base-T) .


Console Port

The Console port (logical port 3) is an RJ45 RS-232 interface on an MIO or UMIO card that provides access to the command line interface (CLI). The interface communicates at 9600 to 115200 bps; the default is 115,200 bps.

IMPORTANT:

A connection to the Console port is required if you wish to view boot messages whenever the ASR 5500 chassis is powered up or rebooted. Only the Console port on the Master MIO or UMIO supports logs and CLI sessions. The Console port on the Standby MIO or UMIO is inactive.

RJ45 Port Pinouts


Table 1. Console Port RJ45 Serial Pinout
Pin Signal Description Signal Type Pinout
1 Not connected —
2 Not connected —
3 Receive Data (RX) Input
4 Signal Ground (SGND) Not applicable
5 Not connected —
6 Transmit Data (TX) Output
7 Not connected —
8 Not connected —


IMPORTANT:

Hardware flow control is not supported and must be disabled on the connected equipment.

RJ45 to DB9 Adapter

An RJ45-to-RJ45 serial cable and an RJ45-to-DB9 adapter are supplied with each MIO or UMIO. The DB9 adapter is female. If you use the cable and adapter together, refer to the following figure and table for the cable pinout.


Table 2. Console RJ45 to DB9Adapter Pinouts
Signal Description Signal type RJ45 Pin DB9 Pin
Not connected — 1 7
Not connected — 2 4
Receive Data (RX) Input 3 3
Signal Ground (SGND) Not applicable 4 5
Not connected — 5 8
Transmit Data (TX) Output 6 2
Not connected — 7 1
Not connected — 8 6


Connect Console Port to Workstation

You can connect the Console port to a workstation with a serial port running a communications application, such as Minicom for Linux® or HyperTerminal® for Windows.

To connect a workstation to the Console port, do the following:

  1. Plug one end of an RJ45 cable to the port labeled Console on the MIO or UMIO.
  2. Plug the other end of the RJ45 cable into the DB9 adapter.
  3. Connect the DB9 end of the adapter into the serial port on the workstation.
  4. Configure the communications application on the workstation to support the following:
    • Baud Rate = 115200 bps
    • Data Bits = 8
    • Parity = None
    • Stop Bits = 1
    • Flow Control = None

Connect Console Port to Terminal Server

You can connect the terminal server to a serial port on a terminal server.

IMPORTANT:

The Console port does not support flow control signaling required by some types of terminal servers. Flow control must be disabled on the connected equipment.

To connect a terminal server to the Console port, do the following:

  1. Plug one end of an RJ45 cable to the port labeled Console on the MIO or UMIO.
  2. Plug the other end of the RJ45 cable into a port on the terminal server.
  3. Configure the communications protocol on the terminal server port to support the following:
    • Baud Rate = 115200 bps
    • Data Bits = 8
    • Parity = None
    • Stop Bits = 1
    • Flow Control = None

    IMPORTANT:

    For additional information on connecting the Console port to Cisco servers equipped with asynchronous interface modules, refer to the Console Port to Cisco Server Cabling appendix.

Ethernet Management Ports

MIOs or UMIOs support two autosensing RJ45 10/100/1000Base-T (IEEE 802.3ab) Ethernet, twisted-pair copper interfaces (logical Ports 1 and 2) for out-of-band system management access to the CLI.

IMPORTANT:

To comply with GR-1089 intra-building, lightning-immunity requirements and FCC Radiated Emissions Criteria, you must use shielded-twisted pair (STP) cable and ensure that it is properly terminated at both ends.

CAUTION:

The 1000Base-T management ports are suitable for connection to intra-building or unexposed wiring or cabling only. These intra-building ports MUST NOT be metallically connected to interfaces that connect to the outside plant (OSP) or its wiring. These interfaces are designed for use as intra-building interfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 5) and require isolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficient protection in order to connect these interfaces metallically to OSP wiring.

The ports support MDI and MDI-X connectors. Ethernet ports normally use MDI connectors and Ethernet ports on a hub normally use MDI-X connectors.

An Ethernet straight-through cable is used to connect an MDI to an MDI-X port. A cross-over cable is used to connect an MDI to an MDI port, or an MDI-X to an MDI-X port.

RJ45 Port Pinouts


Table 3. 1000Base-T RJ45 Ethernet Pinouts
Pin 100Base-T 100Mbps Cat5 1000Base-T 1Gbps Cat5+ Pinout
1 TX+ BI DA+
2 TX- BI DA-
3 RX+ BI DB+
4 — BI DC+
5 — BI DC-
6 RX- BI DB-
7 — BI DD+
8 — BI DD-


Port Status LEDs

Each of these interfaces is equipped with two status LEDs:
  • Link: This green LED shows whether or not the line card is connected to the network. The LED is illuminated when the card is connected.
  • Activity: This green LED shows when data is transmitted or received. The LED is illuminated when data is passing through the interface.

Connect 1000Base-T Interface to Network Device

IMPORTANT:

To facilitate maintenance of the network cabling, the Cat-5 cables should be labeled with terminating destinations.

  1. Insert one end of the Cat-5 cable into the top MGMT connector (Port 1).
  2. Attach the other end of the Cat-5 cable to the appropriate network interface.
  3. Repeat Steps 1 and 2 to connect the bottom MGMT connector (Port 2).

10 GbE Optical Daughter Card Ports

CAUTION:

The 10 Gigabit Ethernet ports on the daughter cards are only certified to work with SFP+ transceivers tested and approved by Cisco. MIO and UMIO cards ship with SFP+ transceivers installed.

The 10 Gigabit Ethernet ports accept the following fiber optic to electrical signal Small Form-Factor Pluggable (SFP+) transceiver types:
  • 10GBase-SR – connects the port to a multimode fiber optic cable over relatively short distances (30.80 meters).
  • 10GBase-LR – connects the port to a single-mode fiber optic cable over a maximum distance of 10km.

The table below lists the signaling parameters supported for the above transceiver types.


Table 4. SFP+ Transceiver Parameters
SFP+ Transceiver Type Parameter Value
10GBase-SR Maximum transmit level -1.0dBm
Minimum transmit level -7.3dBm
Maximum receive level -1.0 dBm (saturation average power)
Minimum receive level -11.1 (sensitivity average power)
10GBase-LR Maximum transmit level 0.5 dBm
Minimum transmit level -8.2 dBm
Maximum receive level 0.5 dBm (saturation average power)
Minimum receive level -12.6 (sensitivity average power)


Fiber Optical Connections

CAUTION:

The SFP+ transceiver modules are static sensitive devices. Always use an ESD wrist strap or similar individual grounding device when coming into contact with SFP+ modules.

CAUTION:

Before connecting fiber optic cables, press each module into the slot firmly with your thumb to firmly reseat them.

Removing Dust Plugs

Before removing the dust plugs and making any optical connections, observe the following guidelines:
  • Always keep the protective dust plugs on the unplugged fiber-optic cable connectors and the transceiver optical bores until you are ready to make a connection.
  • Always inspect and clean the LC connector end-faces just before making any connections.
  • Always grasp the LC connector housing to plug or unplug a fiber-optic cable.

IMPORTANT:

To facilitate maintenance of the network cabling, all fiber optic cables should be labeled with terminating destinations.

Connecting Fiber Optic Cables

  1. Remove the dust plug from the network interface LC connector of the SFP+ module. Save the dust plug for future use.
  2. Inspect and clean the LC connector’s fiber-optic end-faces.
  3. Insert the duplex LC/PC connector on the network cable into the duplex port on the module.
  4. Attach the other end of the network fiber-optic cable to the network device that you want to connect.
  5. Repeat Step 1 through Step 4 for the remaining ports on the daughter card.
  6. Repeat Step 1 through Step 4 for ports on the second DC.