Card Installation

This chapter describes how to install circuit cards in the ASR 5500 chassis.

It includes the following sections:

Card Slot Assignments

The table below shows recommended card slot assignments for typical installation scenarios. The recommended card assignments are based on the multiple power planes sourcing power to the card slots. Refer to the Power Planes section of the Power Cabling chapter for additional information.

Following the recommendations preserves redundant operation if input power is lost to one or more of the power circuits on the PFUs.


Table 1. ASR 5500 Chassis Card Slot Assignments
Slot Card Sequence Requirement
Rear of Chassis
1 DPC-5 or UDPC-5 Available
2 DPC-3 or UDPC-3 Required for all systems
3 DPC-1 or UDPC-1 Required for all systems
4 DPC-7 or UDPC-7 Available
5 MIO-1 or UMIO-1 Required for all systems
6 MIO-2 or UMIO-2 Required for all systems
7 DPC-8 or UDPC-8 Available
8 DPC-2 or UDPC-2 Required for all systems
9 DPC-4 or UDPC-4 Required for all systems
10 DPC-6 or UDPC-6 Available
Front of Chassis
11 SSC-2 Required for all systems
12 SSC-1 Required for all systems
13 FSC-6 Available
14 FSC-4 Required for all systems
15 FSC-2 Required for all systems
16 FSC-3 Required for all systems
17 FSC-1 Required for all systems
18 FSC-5 Available
19 Reserved —
20 Reserved —


Installing Cards

The installation procedure is identical for all cards in the chassis.

CAUTION:

During installation, maintenance, and/or removal, wear a grounding wrist strap connected to the ASR 5500 chassis to avoid ESD damage to the components. Failure to do so could result in damage to sensitive electronic components and potentially void your warranty.

IMPORTANT:

Save several of the shipping cartons and ESD protective bags for use if a card must be returned to Cisco for fault analysis.

IMPORTANT:

On a chassis equipped with the cable management tray, you must lower the tray to insert rear circuit cards. Refer to the Lowering the Cable Management Tray section in the Cable Management System Installation appendix. The cable management tray can be installed after all rear cards have been installed.

IMPORTANT:

Install cable management brackets on MIO cards before inserting the card into the chassis. Refer to the Installing the Cable Management Bracket on an MIO or UMIO Card section in the Cable Management System Installation appendix.

Card Interlock Switch

The top and bottom handles of ASR 5500 circuit cards incorporate hooks that fit behind the upper and lower rails of the card cage. Lifting the handles outwards ejects the card from the midplane. Pushing the handles inwards seats the card into the midplane.

The top handle incorporates an interlock switch that signals the system that a card is seated in the slot. The blue subhandle must be pushed fully upward to engage the interlock switch. The subhandle also locks the top handle against the front of the card. Tightening the captive screw within the top handle secures the subhandle and circuit card to the card cage.


Figure 1. Card Ejector Handle
1 Ejector handle 2 Ejector subhandle (interlock)
3 Captive screw .


Card Installation Procedure

  1. Determine the type of card you are installing. The card type is identified by the label within the bottom handle of the card.
  2. Determine in which chassis slot to install the card based on the information in the table at the beginning of this chapter.
  3. Install front cards from Left to Right. Secure each card before proceeding to the next card.
  4. Install rear cards from Right to Left. Secure each card before proceeding to the next card.
  5. Position both handles on the circuit card to be up and away (outwards) from the front panel of the card.
    1 MIO card 2 Ejector handle
    3 Ejector subhandle (interlock) .


  6. Properly support the weight of the card and align it with the upper and lower card guides of the chassis slot. Gently slide the card into the slot until the levers touch the chassis frame.

    IMPORTANT:

    When installing cards that contain heat sinks, avoid any contact with an adjacent card. Such contact may loosen a heat sink as the card is being slid into the chassis slot.

    CAUTION:

    Never use a cable management bracket on an MIO /UMIO card to lift or insert the card into the chassis. The bracket is not designed to support the weight of the card.

  7. Push both handles inward firmly until the card is seated in the chassis midplane and you cannot push the handles in any further. Press firmly on the card's faceplate to ensure that it is fully seated. The card's front panel should be flush against the chassis' upper and lower card mounts for the slot.
  8. Raise the blue subhandle under the top handle to engage interlock switch. The subhandle also locks the top handle to the front panel.
  9. Use a Phillips #2 screwdriver to tighten the captive screws within the top and bottom handles to secure the card to the chassis.
  10. Repeat step 1 through step 7 for every card you are installing at the rear and front of the chassis.

Baffle Cards

CAUTION:

To ensure proper ventilation, baffle cards must be used in any chassis slot that is not occupied by a circuit card.

Baffle cards consist of a blank front panel mounted to a formed metal baffle. The baffle slides into the card slots and provides a directed path for air flow. There are two types of baffle cards – front and rear.


Figure 2. Front and Rear Baffle Cards

Installing a Front Baffle Card

  1. Flip both ejector handles outward from the front of the card.
  2. Install front baffle cards from Left to Right. Secure each card before proceeding to the next card.
  3. Align the baffle card within an unused chassis slot.
  4. Slide the card into the slot until its front panel is flush with the upper and lower card rails.
  5. Push the ejector handles inward until they are flush with the front of the card.
  6. Use a Phillips #2 screwdriver to tighten the captive screws within the ejector handles on the top and bottom of the card to secure it to the chassis.
  7. Repeat step 1 through step 5 for any additional unused chassis slots.

Installing a Rear Baffle Card

  1. Install rear baffle cards from Right to Left. Secure each card before proceeding to the next card.
  2. Align the baffle card within an unused chassis slot.
  3. Slide the card into the slot until its front panel is flush with the upper and lower card rails.
  4. Use a Phillips #2 screwdriver to tighten the captive screws at the top and bottom of the baffle card to secure it to the chassis.
  5. Repeat step 1 through step 3 for any additional unused chassis slots.

Save Shipping Cartons

Save several of the shipping cartons and protective ESD bags in which the circuit cards were packaged. Use the cartons to package a circuit card for shipment back to Cisco for failure analysis and replacement. For additional information, refer to the Returning Failed Components in the Replacing Components chapter, and the RMA Shipping Procedures appendix.