You must log in as a user with admin privileges to perform this task.
Procedure
Step 1
In the
Navigation pane, click the
Admin tab.
Step 2
On the Admin tab, click Communications Services.
Step 3
In the HTTP Properties area, update the following properties:
Name
Description
HTTP/S Enabled check box
Whether HTTP and HTTPS are enabled on the CIMC.
HTTP Port field
The port to use for HTTP communication. The default is 80.
HTTPS Port field
The port to use for HTTPS communication. The default is 443
Session Timeout field
The number of seconds to wait between HTTP requests before the CIMC times out and terminates the session.
Enter an integer between 60 and 10,800. The default is 1,800 seconds.
Max Sessions field
The maximum number of concurrent HTTP and HTTPS sessions allowed on the CIMC.
This value may not be changed.
Active Sessions field
The number of HTTP and HTTPS sessions currently running on the CIMC.
Step 4
Click Save Changes.
Configuring SSH
Before You Begin
You must log in as a user with admin privileges to configure SSH.
Procedure
Step 1
In the
Navigation pane, click the
Admin tab.
Step 2
On the Admin tab, click Communications Services.
Step 3
In the SSH Properties area, update the following properties:
Name
Description
SSH Enabled check box
Whether SSH is enabled on the CIMC.
SSH Port field
The port to use for secure shell access. The default is 22.
SSH Timeout field
The number of seconds to wait before the system considers an SSH request to have timed out.
Enter an integer between 60 and 10,800. The default is 1,800 seconds.
Max Sessions field
The maximum number of concurrent SSH sessions allowed on the CIMC.
This value may not be changed.
Active Sessions field
The number of SSH sessions currently running on the CIMC.
Step 4
Click Save Changes.
Configuring IPMI
IPMI Over LAN
IPMI defines the protocols for interfacing with a service processor embedded in a server platform. This service processor is called a Baseboard Management Controller (BMC) and resides on the server motherboard. The BMC links to a main processor and other on-board elements using a simple serial bus.
During normal operations, IPMI lets a server operating system
obtain information about system health and control system
hardware. For example, IPMI enables the monitoring of sensors, such
as temperature, fan speeds and voltages, for proactive problem
detection. If server temperature rises above specified levels, the
server operating system can direct the BMC to increase fan speed or
reduce processor speed to address the problem.
Configuring IPMI over LAN
Configure IPMI over LAN when you want to manage the CIMC with IPMI messages.
Before You Begin
You must log in as a user with admin privileges to configure IPMI over LAN.
Procedure
Step 1
In the
Navigation pane, click the
Admin tab.
Step 2
On the Admin tab, click Communications Services.
Step 3
In the IPMI over LAN Properties area, update the following properties:
Name
Description
Enabled check box
Whether IPMI access is allowed on this server.
Privilege Level Limit drop-down list
The highest privilege level that can be assigned to an IPMI session on this server. This can be:
read-only—IPMI users can view information but cannot make any changes. If you select this option, IPMI users with the "Administrator", "Operator", or "User" user roles can only create read-only IPMI sessions, regardless of their other IPMI privileges.
user—IPMI users can perform some functions but cannot perform administrative tasks. If you select this option, IPMI users with the "Administrator" or "Operator" user role can create user and read-only sessions on this server.
admin—IPMI users can perform all available actions. If you select this option, IPMI users with the "Administrator" user role can create admin, user, and read-only sessions on this server.
Encryption Key field
The IPMI encryption key to use for IPMI communications.
Step 4
Click Save Changes.
Configuring SNMP Properties
Before You Begin
You must log in as a user with admin privileges to perform this task.
Procedure
Step 1
In the
Navigation pane, click the
Admin tab.
Step 2
On the Admin tab, click Communications Services.
Step 3
In the Communications Services pane, click the SNMP tab.
Step 4
In the SNMP Properties area, update the following properties:
Name
Description
Enabled check box
Whether this server sends SNMP traps to the designated host.
SNMP Port field
The port the server uses to communicate with the SNMP host.
This value cannot be changed.
Access Community String field
The default SNMP v1 or v2c community name or SNMP v3 username CIMC includes on any trap messages it sends to the SNMP host.
Enter a string up to 18 characters.
System Contact field
The system contact person responsible for the SNMP implementation.
Enter a string up to 254 characters, such as an email address or a name and telephone number.
System Location field