A platform event filter (PEF) can trigger an action and generate an alert when a critical hardware-related event occurs. For each PEF, you can choose the action to be taken (or take no action) when a platform event occurs. You can also choose to generate and send an alert when a platform event occurs. Alerts are sent as an SNMP trap, so you must configure an SNMP trap destination before the alerts can be sent.
You can globally enable or disable the generation of platform event alerts. When disabled, alerts are not sent even if PEFs are configured to send them.
Enabling Platform Event Alerts
Before You Begin
You must log in as a user with admin privileges to enable platform event alerts.
Procedure
Step 1
In the
Navigation pane, click the
Admin tab.
Step 2
On the Admin tab, click Event Management.
Step 3
In the Event Management pane, click the Platform Event Filters tab.
Step 4
In the Platform Event Alerts area, check the Enable Platform Event Alerts check box.
Step 5
Click Save Changes.
Disabling Platform Event Alerts
Before You Begin
You must log in as a user with admin privileges to disable platform event alerts.
Procedure
Step 1
In the
Navigation pane, click the
Admin tab.
Step 2
On the Admin tab, click Event Management.
Step 3
In the Event Management pane, click the Platform Event Filters tab.
Step 4
In the Platform Event Alerts area, uncheck the Enable Platform Event Alerts check box.
Step 5
Click Save Changes.
Configuring Platform Event Filters
Before You Begin
You must log in as a user with admin privileges to configure platform event filters.
Procedure
Step 1
In the
Navigation pane, click the
Admin tab.
Step 2
On the Admin tab, click Event Management.
Step 3
In the Event Management pane, click the Platform Event Filters tab.
Step 4
In the Platform Event Filters area, complete the following fields for each event:
Name
Description
ID column
The unique filter ID.
Event column
The name of the event filter.
Action column
For each filter, select the desired action from the scrolling list box. This can be:
None—An alert is sent but no other action is taken
Reboot—An alert is sent and the server is rebooted
Power Cycle—An alert is sent and the server is power cycled
Power Off—An alert is sent and the server is powered off
Send Alert column
For each filter that you want to send an alert, check the associated check box in this column.
Note
In order to send an alert, the filter trap settings must be configured properly and the Enable Platform Event Alerts check box must also be checked.
Step 5
Click Save Changes.