Table Of Contents
Cabling Summary
Introduction
T3 Trunk Cabling
Frame Relay Cabling
T1 Cabling
E1 Cabling
BNC Connector
DB15 Connector
12IN1-S4 V.35/X.21 Back Card
HSSI Port Connectors
Cabling for RJ-48 Connectors on T1 and E1 Ports
DC Power Cabling
AC Power Cabling
Control and Clock Cabling
Maintenance and Control Ports
Modem Cable
External Clock Input Cabling
T1/E1 Clock Cabling
E1 Clock Cabling
External Alarm Cabling
Standard MGX 8850 Cables
Redundancy Y-Cable
Cabling Summary
Introduction
This appendix contains details on the MGX 8850 cabling.
Note
In all cable references, the transmit direction is away from the switch, and the receive direction is towards the switch.
T3 Trunk Cabling
A trunk cable connects each T3 port on the BNC-2T3 back card to a T3 port on the co-located BPX-8600-series node. Refer to Table B-1 and Table B-2 for details.
Table B-1 Trunk Cables
Cable Parameter
|
Description
|
Type:
|
75-ohm coax cable (RG-59 B/U for short runs, AT&T 734A for longer runs). Two per T3 line (XMT and RCV).
|
Max. Length:
|
450 feet max. between the BPX 8600-series node and the MGX 8850 node.
|
Connector:
|
Terminated in male BNC; Rx is received from trunk, Tx is transmitted to trunk.
|
Table B-2 T3 Connector Pin Assignments
Connector
|
Description
|
Rx BNC
|
Receive T3 from trunk
|
Tx BNC
|
Transmit T3 to trunk
|
Frame Relay Cabling
This section describes the cabling and connector pinouts for the Frame Relay cards.
T1 Cabling
Trunk cables connect the customer DSX-1 cross-connect point or T1 Channel Service Unit (CSU) to the node at the T1 back card. Refer to Table B-3 and Table B-4 for details.
Table B-3 T1 Trunk/Circuit Line Cabling Specification
Cable Parameter
|
Description
|
Cable Type:
|
Western Electric 22 AWG, ABAM individually shielded twisted pair (100 ohm balanced). Two pair per T1 line (1 transmit and 1 receive).
|
Cable Connector:
|
Male DB-15 subminiature.
|
Max. Cable Length:
|
533 ft. (162 m) maximum between the MGX 8850 node and the first repeater or CSU. Selection of cable length equalizers.
|
Table B-4 T1 Connector Pin Assignments
Pin No.
|
Description
|
1
|
Transmit, Tip
|
2
|
Transmit Pair Shield
|
3
|
Receive, Tip
|
4
|
Receive Pair Shield
|
9
|
Transmit, Ring
|
11
|
Receive, Ring
|
Note
Transmit direction is towards the T1 trunk.
E1 Cabling
BNC Connector
E1 trunk cables connect the customer DSX-1 cross-connect point or E1 Channel Service Unit (CSU) to the node at the FRSM E1 back card (BNC-8E1). Refer to Table B-5 and Table B-6.
Table B-5 E1 Trunk/Circuit Line Cabling Specification
Cable Parameter
|
Description
|
Cable Type: BNC-8E1
|
75-ohm coax cable for unbalanced connection. Two cables/pairs (1 transmit, 1 receive) per E1 line.
|
Cable Connector:
|
Two female BNC for unbalanced connection; male DB15 for balanced connection. Refer to Tables A-2 and A-3 for pinouts.
|
Max. Cable Length:
|
Approximately 100 meters maximum between the MGX 8850 node and the first repeater or CSU. Equalizer for cable length.
|
Table B-6 E1 Connector Pin Assignments (unbalanced)
Connector
|
Description
|
Rx BNC
|
Receive E1 from trunk
|
Tx BNC
|
Transmit E1 to trunk
|
DB15 Connector
E1 trunk cables connect the customer DSX-1 cross-connect point or E1 CSU to the node at the FRSM E1 back card (DB15-8E1). Refer to Table B-7 and Table B-8.
Table B-7 E1 Trunk/Circuit Line Cabling Specification
Cable Parameter
|
Description
|
Cable Type: DB15-8E1
|
Western Electric 22 AWG, ABAM individually shielded twisted pair (120 ohm balanced). Two pair per T1 line (1 transmit and 1 receive).
|
Cable Connector:
|
Male DB-15 subminiature.
|
Max. Cable Length:
|
533 ft. (162 m) maximum between the MGX 8850 node and the first repeater or CSU. Selection of cable length equalizers.
|
Table B-8 E1 Connector Pin Assignments
Pin No.
|
Description
|
1
|
Transmit, Tip
|
2
|
Transmit Pair Shield
|
3
|
Receive, Tip
|
4
|
Receive Pair Shield
|
9
|
Transmit, Ring
|
11
|
Receive, Ring
|
Note
Transmit direction is towards the E1 trunk.
12IN1-S4 V.35/X.21 Back Card
The back card for the MGX-FRSM-HS1/B is the 12IN1-S4. Each port on the back card connects through a DTE version or DCE version of the Cisco 12IN1 cable. For the signals on the back card, see Table B-10 and Table B-11. The tables show the signal acronym, signal name, and signal source. The signal depends whether the backcard connector is either DTE or DCE and whether the backcard has been set as either X.21 or V.35 as shown in Table B-9. For the part numbers of the standard and non-standard versions of the 12IN1 cables, see Table B-12.
Table B-9 12IN1-S4 cable types
Cable Type
|
X.21
|
V.35
|
DCE
|
X.21 DCE
|
V.35 DCE
|
DTE
|
X.21 DTE
|
V.35 DTE
|
Note
The cable type and part number are printed on a plastic band located near the smaller connector.
Table B-10 V.35 signals
Signal
|
Name
|
Source
|
RTS
|
Request to Send
|
DTE
|
DTR
|
Data Terminal Ready
|
DTE
|
CTS
|
Clear To Send
|
DCE
|
DSR
|
Data Set Ready
|
DCE
|
DCD
|
Data Carrier Detect
|
DCE
|
GND
|
Ground
|
both
|
B_LL
|
Local Loopback
|
DTE
|
GND
|
Ground
|
both
|
TxD+
|
Transmit Data
|
DTE
|
TxD-
|
Transmit Data
|
DTE
|
RxD+
|
Receive Data
|
DCE
|
RxD-
|
Receive Data
|
DCE
|
TXCE
|
Secondary Clear to Send
|
DTE
|
TXCE
|
Secondary Clear to Send
|
DTE
|
RxC+
|
Receive Clock
|
DCE
|
RxC-
|
Receive Clock
|
DCE
|
TxC+
|
Transmit Clock
|
DCE
|
TxC-
|
Transmit Clock
|
DCE
|
Table B-11 X.21 Signals
Signal
|
Name
|
Mode_2
|
Local connections
|
Mode_DCE
|
Local connections
|
Gournd
|
Shield Ground
|
O_TXD/RSC+
|
Transmit +
|
OTXD/RXD-
|
Transmit -
|
O_RTS/CTS+
|
Control +
|
O_RTS/CTS-
|
Control -
|
I_RDX/TXD+
|
Receive +
|
I_RXD/TXD-
|
Receive -
|
ICTS/RTS+
|
Indication +
|
I_CTS/RTS-
|
Indication -
|
I_RXC/TXCE+
|
Timing +
|
I_RXC/TXCE-
|
Timing -
|
GND
|
CCT Ground
|
Table B-12 Cable Part Numbers for MGX-FRSM-HS1/BV
Type of Cable
|
Far End Connector
|
Part Number
|
X.21 DTE
|
male
|
72-1440-01
|
X.21 DCE
|
fremale
|
72-1427-01
|
V.35 DTE
|
male (standard)
|
72-1428-01
|
V.35 DTE
|
female (atypical)
|
72-1436-01
|
V.35 DCE
|
female (standard)
|
72-1429-01
|
V.35 DCE
|
male (atypical)
|
72-1437-01
|
V.35 DTE-DCE
|
|
72-1441-01
|
Straight-through
|
|
72-1478-01
|
Loopback plug
|
|
72-1479-01
|
HSSI Port Connectors
The High Speed Serial Interface (HSSI) port connects through a female SCSI-II connector. This connector accords with ANSI/TIA/EIA-613. Refer to Table B-13 for the pinouts.
Table B-13 Pinouts for SCSI-II Connector
Pin No.
|
Name
|
Signal Function
|
Polarity
|
Signal Source
|
11
|
SD
|
Send Data
|
+
|
DTE
|
36
|
|
|
-
|
|
4
|
RD
|
Receive Data
|
+
|
DCE
|
29
|
|
|
-
|
|
6
|
ST
|
Send Timing
|
+
|
|
31
|
|
|
-
|
|
2
|
RT
|
Receive Timing
|
+
|
|
27
|
|
|
_
|
|
6
|
TT
|
Terminal Timing
|
+
|
DCE
|
13
|
|
|
-
|
|
3
|
CA
|
DCE Available
|
+
|
DCE
|
28
|
|
|
-
|
|
8
|
TA
|
DTE Available
|
+
|
DTE
|
33
|
|
|
-
|
|
10
|
LA
|
Loop Ckt A
|
+
|
DTE
|
35
|
|
|
-
|
|
12
|
LB
|
Loop Ckt B
|
+
|
DTE
|
37
|
|
|
-
|
|
5
|
LC
|
Loop Ckt C
|
+
|
DCE
|
30
|
|
|
-
|
|
1,26,7,32,13,38,19,44,25,50
|
SG
|
Signal Ground
|
|
|
Cabling for RJ-48 Connectors on T1 and E1 Ports
For T1 and E1 ports that connect through a RJ-48 connector, each connector has:
•
Transmit TIP pin
•
Transmit RING pin
•
Receive TIP pin
•
Receive RING pin
•
Two pins for shielded ground
An illustration of the connector wiring appears in Figure B-1.
Figure B-1 RJ-48 Connectors
DC Power Cabling
DC Power connections are made to the DC Power Entry Modules at the rear of the MGX 8850 node. (See Figure B-2.) See Table B-14 and Table B-15 for acceptable cable and wire types. Cisco normally does not provide wiring for DC-powered systems. See Table B-14 for details on DC wiring.
Table B-14 DC Power Wiring
Cable Parameter
|
Description
|
Wiring:
|
Three conductor, 12 AWG recommended wire gauge, min. 60×C insulation rating, copper conductors only. Solid or stranded wires. Wire insulation stripped back 0.25 in (6 mm) at the MGX 8850 connector end.
|
Connection:
|
EURO Block.
|
Figure B-2 DC Power Connections
AC Power Cabling
Either Cisco Systems or the customer can provide the AC power cord. See Table B-15 for the power cords that Cisco can supply. In addition, you can special-order AC cables with other plugs or different lengths. If you want to construct the power cord, it must mate with an IEC320 16/20A male receptacle on the back of the AC power module.
Table B-15 AC Power Cables
Cable Parameter
|
Description
|
Cable:
|
Provided with 8 feet (2.3 m) of 3-conductor wire with plug.
|
Plug: customer end
|
20 A NEMA L620, 3-prong plug (domestic U.S.) 13 A 250 Vac BS1363, 3-prong fused plug (UK, Ireland) CEE 7/7 (Continental Europe) AS3112 (Australia/New Zealand) CEI23-16/VII (Italy)
|
Control and Clock Cabling
This section describes the cables that can connect to the PXM-UI card.
Maintenance and Control Ports
The Maintenance (or Modem) port and the Control (or Console) port connect a node to an ASCII terminal, workstation, or modem for remote alarm reporting or system monitoring. Refer to Table B-16 for a description of the cabling and Table B-17 for the pinout of the associated RJ-48 connector.
Table B-16 Maintenance and Control Port Cabling
Cable Parameter
|
Description
|
Interface:
|
EIA/TIA-232—both are DTE ports.
|
Suggested Cable:
|
24 AWG, 25-wire. A straight-through EIA/TIA-232 cable provides a terminal or printer connection. For an interface with modems on either port, a null modem cable may be necessary.
|
Cable Connector:
|
RJ-48, subminiature, male. Table B-17 contains a list of the port pin assignments.
|
Max. Cable Length:
|
50 feet (15 m)
|
Table B-17 Maintenance and Control Port Pin Assignments
Pin No.
|
Name
|
Description
|
1
|
RTS out
|
Request to Send
|
2
|
DTR out
|
Data Terminal Ready
|
3
|
TxD
|
Transmit Data
|
4
|
GND
|
Chassis ground
|
5
|
GND
|
Chassis ground
|
6
|
RxD
|
Receive Data
|
7
|
DSR
|
Data Set Ready
|
8
|
CTS
|
Clear to Send
|
Modem Cable
shows a modem cable that is used for connecting modems to the MGX 8850 control and maintenance ports.
Figure B-3 Null Modem Cable
External Clock Input Cabling
The external clock input cable connects the external clock inputs through the T3E3-D, T3E3-B and SMF-155 EXT. TMG. connectors. The clock may be 1.544 Mbps for T3E3-D or 2.048 Mbps for T3E3-D. See Table B-18 through Table B-21.
T1/E1 Clock Cabling
The DB15 clock port can accept a T1 or E1 BITS clock input.
Table B-18 External Clock Cabling—T3E3-D or SMF-155
Cable Parameter
|
Description
|
Cable Type:
|
Western Electric 22 AWG, ABAM individually shielded twisted pair (100 ohm balanced). One pair per T1 line (1 receive).
|
Cable Connector:
|
Male DB-15 subminiature. Refer to Table B-19 for pinouts.
|
Max. Cable Length:
|
533 ft. (162 m) maximum between the MGX 8850 node and the first repeater or CSU. Selection of cable length equalizers is used. Wire build-out is required.
|
.
Table B-19 T1 Connector Pin Assignments for EXT. TMG
Pin No.
|
Description
|
1
|
|
2
|
Transmit Pair Shield
|
3
|
Receive, Tip
|
4
|
Receive Pair Shield
|
9
|
|
11
|
Receive, Ring
|
E1 Clock Cabling
Table B-20 E1 Clock Cabling—T3E3-B
Cable Parameter
|
Description
|
Cable Type
|
75-ohm coax cable for unbalanced connection. One cable pair per E1 clock input.
|
Cable Connector:
|
One female BNC for unbalanced connection; male DB15 for balanced connection.
|
Max. Cable Length:
|
Approximately 100 meters maximum between the MGX 8850 node and the first repeater or CSU. Equalizer for cable length.
|
Table B-21 E1 Connector Pin Assignments for EXT.TMG (unbalanced)
Connector
|
Description
|
Rx BNC
|
Receive E1 from trunk
|
External Alarm Cabling
The external alarm cable connects to the Alarm connector on the PXM-UI card. See Table B-22 for physical characteristics of the cable and Table B-23 for the pinouts.
Table B-22 External Alarm Cabling
Cable Parameter
|
Description
|
Interface:
|
Dry-contact relay closure.
|
Wire:
|
24 AWG, shielded, 6-pair.
|
Connector:
|
DB-15, Subminiature, male.
|
Table B-23 Network Alarm Pin Assignments
Pin No.
|
Alarm
|
Description
|
1
|
Audible—Major
|
Normally open
|
2
|
|
Common
|
9
|
|
Normally closed
|
4
|
Visual—Major
|
Normally open
|
5
|
|
Common
|
12
|
|
Normally closed
|
7
|
unused
|
n.c.
|
8
|
unused
|
n.c.
|
3
|
Audible—Minor
|
Normally open
|
11
|
|
Common
|
10
|
|
Normally closed
|
6
|
Visual—Minor
|
Normally open
|
14
|
|
Common
|
13
|
|
Normally closed
|
15
|
unused
|
n.c.
|
Standard MGX 8850 Cables
For a list of the standard cables that Cisco can supply for the MGX 8850 switch, see Table B-24. The suffix to the model number indicates the length of the cable. For example, 5610-50 indicates a 50-foot cable. Cables are available in standard lengths of 10 ft. (3 m), 25 ft. (7.6 m), 50 ft. (15 m), 75 ft. (22.8 m), and 100 ft. (30 m). Lengths of 100 ft. (30 m) to 600 ft. (183 m) are available through a special order.
Where applicable, Table B-24 includes the gender of the connector and the number of pins. For example, EIA/TIA-232/M25-M25 indicates a cable terminated with a male DB25 at both ends.
Table B-24 Standard Cables Available from Cisco
Model Number
|
Description
|
Usage
|
| |
|
|
T3-E3-10 T3-E3-25 T3-E3-50 T3-E3-75 T3-E3-xx
|
75 W coax/BNC-BNC, 10' 25' 50' 75' length to be specified
|
T3 or E3 trunk interface
|
5620
|
EIA/TIA-232/M25-F25
|
PXM-UI maintenance port to control terminal, WAN Manager, or external window device
|
5621
|
EIA/TIA-232/M25-M25 special
|
Control or maintenance port to modem
|
5601
|
Ground cable
|
DC power
|
5670
|
Molex-pigtail
|
DC power
|
5671
|
Spade lug-pigtail
|
DC power
|
Redundancy Y-Cable
Special Y-cables provide line redundancy where applicable. (The Service Resource Module can also provide redundancy where certain Y-cables do not apply.) Table B-25 lists the Y-cables used with various MGX 8850 cards.
Table B-25 Y-Cable Product Names for Applicable Cards
Applicable Card Name
|
Connector Hardware
|
Type/Standard Interface
|
Product Number
|
PXM-UI
|
RJ45
|
EIA/TIA-232
|
CAB-5684-06 (6-inch Y)
|
PXM-UI
|
RJ45
|
EIA/TIA-232
|
CAB-5684-18
|
PXM-UI
|
RJ45
|
T1 BITS Clock
|
CAB-5686-06 (6-inch Y)
|
PXM-UI
|
SMB
|
E1 BITS Clock
|
CAB-5681-06 (6-inch Y)
|
PXM-UI
|
SMB
|
E1 BITS Clock
|
CAB-5681-18 (18-inch Y)
|
PXM-UI
|
DB15
|
Alarm Output
|
CAB-5607-10 (10-inch Y)
|
PXM-4-155
|
SC
|
SMF, MMF
|
CAB-SMF-Y-SC
|
PXM-1-622
|
SC
|
SMF
|
CAB-SMF-Y-SC
|
PXM-2T3E3
|
BNC
|
75 ohm, coaxial
|
CAB-T3E3-Y
|
MGX-BNC-3T3-M
|
BNC
|
75 ohm, coaxial
|
CAB-T3E3-Y
|
MGX-FRSM-2T3E3
|
BNC
|
75 ohm, coaxial
|
CAB-T3E3-Y
|
MGX-CESM-T3E3
|
BNC
|
75 ohm, coaxial
|
CAB-T3E3-Y
|
MGX-FRSM-HS2
|
SCSI2
|
|
CAB-SCSI2-Y
|
SMSCFC010250-01M
|
SC to FC
|
|
72-1246-01
|