Table Of Contents
Error Messages for MGX and SES Release 4.0.00
ACAR-2-SHLFINIT
ACAR-2-SHLFINIT_ENDPT
ACAR-2-DBINIT
DDTS "pxm-connmgm"
CM_L-7-CM_LMI_NO_ALM_C
CM_L-7-CM_LMI_INIT_SUC
CM_L-4-CM_LMI_MEM_ERRO
CM_L-4-CM_LMI_ERR_GEN
CM_L-5-CM_LMI_ERR_SLOT
CM_L-2-CM_LMI_ERR_PORT
CM_L-4-CM_LMI_ERR_MSGQ
CM_L-5-CM_LMI_ERR_SET_
CM_L-4-CM_LMI_ERR_SCHE
CM_L-4-CM_LMI_CREATE_T
CM_L-5-CM_LMI_LSLOT_ER
CM_L-5-CM_LMI_PSLOT_ER
DDTS "pxm-connmgm"
ACAR-2-SHLFINIT
ACAR-2-SHLFINIT_ENDPT
ACAR-2-DBINIT
ACAR-2-SMM_ERROR_GEN
ACAR-4-MSG_PROC_ERR
ACAR-4-CHK_ERR
ACAR-7-INFO_LOG
DDTS "shm"
RED-7-DETECT_MISMATCH
RED-7-MSG_DATA_ERROR
RED-7-AC_SEND_MSG_ERR
RED-7-AC_GEN_ERR
RED-4-NACK_ERR
RED-7-AC_INFO_ERR
RED-7-TBL_UPD_INFO
RED-7-AC_SWITCHCARD_I
RED-7-AC_MEM_ERR
RED-7-AC_TIME_OUT_ERR
RED-7-AC_WRNGMSG_ERR
RED-7-AC_DWNLBRAMERR
RED-7-AC_UPLDBRAMERR
RED-7-BADARCERR
RED-7-SMM_ERROR_GEN
RED-7-SMM_INFO
RED-7-SMM_GEN_ERR
RED-7-BAD_SHLF_SLOT
RED-7-RAM_SYNC_IOV_FA
RED-7-RAM_SYNC_IOV_SE
RED-4-MSGQ_BIND_FAIL
RED-4-IPC_COM_EPID_FA
RED-4-PIPC_PORT_CREAT
RED-4-INIT_TBL_FAILED
RED-7-SM_MSG_RCVD
RED-6-AC_INCORRECT_ST
RED-6-AC_INVALID_MSG
RED-4-DOWNLOAD_FAILED
RED-7-DOWNLOAD_PASSED
RED-7-PMM_MSG_RCVD
RED-4-CD_STATE_MISMAT
RED-7-PMM_EVENT_SET
RED-7-SM_STATE_EVENT
RED-5-SM_STATE_CHANGE
RED-7-SM_INVALID_EVEN
RED-5-SEND_MISMATCH_M
RED-5-IPC_MSG_RVC_ERR
RED-5-SSI_RCVID_ERROR
RED-5-IPC_MSG_ALLOC_F
RED-5-IPC_MSG_REPLY_F
RED-5-CLI_INVALID_PAR
RED-5-CLI_NULL_PARAM
RED-5-IPC_MSG_SEND_FA
RED-5-IPC_DATAPTR_NUL
RED-4-RED_CMD_MISMATC
RED-7-INV_CLI_CMD
RED-5-FW_UPGD_FAIL
RED-5-CTC_INV_EVENT
RED-4-CD_REMOVED
RED-4-CD_FAILED
RED-7-AC_ADDRED_INFO
RED-7-AC_DELRED_INFO
RED-7-CD_STATE_INFO
RED-7-PRIMARY_NOT_PRO
RED-7-SEC_CD_INFO
RED-7-LINEMODULE_INFO
RED-7-AC_MIB_MISMATCH
RED-7-DWLD_INFO
RED-5-DWLD_FOPEN_FAIL
RED-4-DWLD_FAILED
RED-4-AC_INIT_FAIL
RED-5-AC_INIT_ERR
RED-7-AC_INIT_INFO
RED-7-REDUNDANCY_INFO
RED-4-PMM_CD_RESET
RED-5-SM_INSERT_MSG
RED-4-SM_FAILED_MSG
RED-4-SM_MISMATCH_MSG
RED-4-SM_REMOVED_MSG
RED-7-CARD_FAIL_INFO
RED-7-SHM_MSGRCV
RED-7-CMD_FAILED
DDTS "alarms"
CAMA-5-INVALIDINPUT
CAMA-5-PARMOUTOFTRANGE
CAMA-5-PARMINVALID
CAMA-5-PARMINVLENGTH
CAMA-5-FUNCFAIL_STKDUM
CAMA-5-QUEUEFULL
DDTS "unknown"
AUPL-5-INVD_INPT
AUPL-4-INVD_RET
AUPL-4-INVD_VAL
AUPL-4-INVD_STR
AUPL-4-INVD_INPT
AUPL-4-INVD_RET
AUPL-4-INVD_VAL
AUPL-4-INCRT_CALL
DDTS "axsm_apps"
APS-4-APS_MAIN_ERR
APS-4-APS_MUX_ERR
APS-4-INIT_ERR
APS-4-APS_MSG_ERR
APS-4-APS_IPC_COMEP_C
APS-4-APS_IPC_COMEP_U
APS-4-APS_IPC_COMEP_N
APS-4-APS_IPC_MSG_SEN
APS-4-APS_IPC_MSG_ALL
APS-4-APS_EM_REPORT_F
APS-4-APS_MSG_HNDLR_I
APS-4-APS_RMI_SEND_FA
APS-4-APS_RMI_CTXT_PU
APS-4-APS_RMI_USER_AC
APS-4-APS_RMI_ACKDATA
APS-4-APS_RMI_MSG_ALL
APS-4-APS_INVALID_CAR
APS-4-APS_RMI_LINE_PA
APS-4-APS_RMI_UNACK_D
APS-4-APS_RMI_SYNC_DA
APS-4-APS_RMI_RMT_EPI
APS-4-APS_UNKNOWN_MSG
APS-4-RMI_UNACK_DATAS
APS-4-APS_RMI_PORT_CR
APS-4-APS_INVALID_EPI
APS-4-APS_INVALID_CTC
APS-4-APS_RMT_BKCD_DE
APS-4-APS_RMT_FRONTCD
APS-4-APS_INVALID_CTC
APS-7-APS_AISL_DECL
APS-7-APS_PRDI
APS-7-APS_SF_DECL
APS-7-APS_SELECTOR_RE
APS-7-APS_PROT_LINE_S
APS-7-APS_BRIDGE_RELE
APS-7-APS_WORKCHAN_BR
APS-7-APS_TXK1
APS-7-APS_TXK2
APS-7-APS_RXK1
APS-7-APS_RXK2
APS-7-APS_PROVISION
APS-7-APS_DELETE
APS-7-APS_CONFIG_SF_B
APS-7-APS_CONFIG_SD_B
APS-7-APS_CONFIG_WTR
APS-7-APS_CONFIG_DIR
APS-7-APS_CONFIG_REV
APS-7-APS_USER_SWITCH
APS-7-APS_PSB_INVALCH
APS-7-APS_PSB_INVALCO
APS-7-APS_PSB_INCONSB
APS-7-APS_PSB_IRRELEV
APS-7-APS_PSB_FAILURE
APS-7-APS_PSBF_CLEARE
APS-7-APS_CHMM_CLEARE
APS-6-ADD_LN
APS-6-DEL_LN
APS-3-SW_CLEAR
APS-3-SW_LOCK
APS-3-SW_FORCE_WTOP
APS-3-SW_FORCE_PTOW
APS-3-SW_MAN_WTOP
APS-3-SW_MAN_PTOW
APS-2-PSB_FAIL
APS-2-CHAN_MISMATCH
APS-2-PRIM_SEC_MISMAT
APS-6-CNF_SFBER
APS-6-CNF_SDBER
APS-6-CNF_WTR
APS-6-CNF_DIR
APS-7-CNF_PROTO
APS-7-CNF_OPMODE
APS-7-APS_OPMODE_ERR
APS-6-CNF_REV
APS-3-SF_DECL
APS-3-SF_DECL_CLEAR
APS-3-SW_SERVICE
APS-4-PSBF_CLEARED
APS-4-CHAN_MIS_CLEARE
APS-2-FAR_END_FAIL
APS-2-FAR_END_FAIL_CL
APS-2-MODE_MISMATCH
APS-6-MODE_MIS_CLEAR
APS-4-SW_CLEAR_FAIL
APS-4-SW_LOCK_FAIL
APS-4-SW_FORCE_WTOP_F
APS-4-SW_FORCE_PTOW_F
APS-4-SW_MAN_WTOP_FAI
APS-4-SW_MAN_PTOW_FAI
APS-3-SD
APS-3-SD_CLEAR
APS-3-SW_SF
APS-3-SW_SD
APS-3-SW_REV
APS-3-SW_DONOT_REV
APS-3-SW_WTR
APS-3-SW_UNKNOWN
APS-4-SW_SF_FAIL
APS-4-SW_SD_FAIL
APS-4-SW_REV_FAIL
APS-3-SW_DONOT_REV_FA
APS-7-APS_CHMM_FAILUR
APS-4-APS_PHY_ERR
APS-4-APS_PHY_BAD_PAR
DDTS "unknown"
SSI-4-ARCH_ERROR
DDTS "pxm-connmgm"
SSI-4-ARCH_ERROR
DDTS "shm"
ENVM-4-ADC_CONV_ERROR
ENVM-4-ADC_ERROR
ENVM-2-ENV_ALARM_SET
ENVM-3-ENV_ALARM_CLR
ENVM-4-ENV_TRAP_GEN
ENVM-4-ENV_ERROR
DDTS "drivers/ccma"
ATLA-4-AT_INIT_ERR
ATLA-4-AT_INTRPT_ERR
ATLA-4-AT_GEN_ERR
ATLA-4-AT_PARAM_ERR
ATLA-4-AT_ACCESS_ERR
ATLA-4-AT_CONACC_ERR
DDTS "atmsig"
ATMC-5-INTERNAL_CRITIC
ATMC-5-P2MP_ERR
ATMC-5-P2MP_WARN
ATMC-7-P2MP_INFO
ATMS-4-ATMSIG_PRTY_INS
ATMS-4-ATMSIG_PRTY_DEL
ATMS-4-ATMSIG_SVC_INSE
ATMS-4-ATMSIG_SVC_DELE
ATMS-4-NOSVC
ATMS-4-NOCALLREF
ATMS-6-FAILHALFLEGREM
ATMS-4-FAIL2NDHALFLEG
ATMS-4-FAILXCONN
SCHE-4-UNEXPECTEDMESSA
SCHE-4-UNEXPECTEDEVENT
SCHE-4-UNEXPECTEDTIMER
DDTS "unknown"
ADDR-5-ADDR_ERROR
ADDR-7-ADDR_INFORMATIV
DDTS "ifm"
IFM-4-ERROR
IFM-5-WARNING
IFM-7-INFO
IFM-6-NOTICE
DDTS "atmsig"
VCM-6-LEG_CREATE
ATMC-5-INTERNAL_WARNIN
ATMC-5-SETCAC_WARN
ATMC-5-BITMAP_ERR
ATMC-5-BITMAP_WARN
ATMC-7-BITMAP_INFO
DDTS "atmsig"
TRAF-5-ADDFAIL
TRAF-5-DELFAIL
TRAF-5-NOABRPARM
TRAF-5-DBCREATEFAIL
TRAF-5-NULLPTR
TRAF-5-NULLELEPTR
TRAF-5-BADELE
TRAF-5-BADELECHKSUM
TRAF-5-BROKENLIST
TRAF-5-NOTINFREELIST
TRAF-5-NOTINUSE
TRAF-5-NOTALLOC
TRAF-5-CANNOTFREE
TRAF-5-MISMATCHCKSM
TRAF-5-DECREFCNTFAIL
TRAF-5-DECREMENTERR
TRAF-5-INVTRFIDX
TRAF-5-ALLOCFAIL
TRAF-5-INSERTFAIL
TRAF-5-NEWBLKALLOCFAIL
TRAF-5-BUFALLOCFAIL
TRAF-7-NOTENGBUF
TRAF-7-CONGOFF
DDTS "unknown"
VCM-5-WARNING
VCM-7-INFO
VCM-6-NOTICE
VCM-7-CONN_INSTALLSVC
CM-7-CONN_ALLOCVXL_E
DDTS "unknown"
VCM-7-VCM_INSTALL_XCO
VCM-7-VCM_BIG_DELETE_
VCM-7-VCM_RECOMMIT_TI
VCM-7-VCM_FRCE_RESYNC
VCM-6-NOTICE
DDTS "unknown"
CSR-7-INFO
CSR-6-NOTICE
CSR-5-WARNING
CSR-4-ERROR
CSR-7-CONGEST
CSR-7-NULL_PTR
CSR-7-MALLOC_FAIL
CSR-7-TIMEOUT
CSR-7-ABORT_FAIL
CSR-7-INTF
CSR-7-PEP
CSR-7-DISK_FAIL
CSR-7-START_END
CSR-7-BUFFER_UPDT
CSR-7-REDO_UPDT
DDTS "spvc"
SPVC-4-SWERROR
DDTS "axsm-apps/shm"
AXDG-4-ERR
AXDG-4-LOGTRC
AXDG-7-OFFLN
AXDG-7-ONLN_STATUS
DDTS "boot/shm"
BOOT-5-SERIALHUNGHCR
BOOT-5-SERIALHUNGREAD
BOOT-5-SERIALHUNGWRITE
BOOT-5-ETHERCHIPHUNG
BOOT-2-LANLOSTCARR
BOOT-2-LANLOSTCARR_CLR
BOOT-4-HMASTER_NO_HREA
BOOT-5-UNEXPECTED_INTE
BOOT-4-UNEXPECTED_INTE
BOOT-7-BURNBOOT_REQ_DE
BOOT-4-BURNBOOT_SIGFIL
BOOT-4-BURNBOOT_SIGFIL
BOOT-4-BURNBOOT_SW_ID_
BOOT-4-BURNBOOT_VER_IN
BOOT-4-BURNBOOT_KEY_IN
BOOT-7-BURNBOOT_SIGFIL
BOOT-7-BURNBOOT_BRAM_C
BOOT-7-BURNBOOT_VERSIO
BOOT-7-BURNBOOT_KEY_MA
BOOT-4-BURNBOOT_FAILED
BOOT-2-BURNBOOT_FAILED
BOOT-7-BURNBOOT_REQ_HA
BOOT-4-W_RODATA
DDTS "atmsig"
CA-4-CA_IPC_ERROR
CA-4-CA_TIMER_START_
CA-4-CA_GENERIC_ERRO
CA-6-CA_GENERIC_NOTI
DDTS "alarms"
CAM-5-INVALIDINPUT
CAM-5-PARMOUTOFTRANGE
CAM-5-PARMINVALID
CAM-5-PARMINVLENGTH
CAM-5-FUNCFAIL_STKDUM
CAM-5-QUEUEFULL
DDTS "ccma"
DAL-4-DALERR
DAL-4-DALERR_STR
DDTS "snmp-ma"
CB_S-4-INVALIDINPUT
CB_S-4-PARMINVALID
CB_S-4-PARMINVLENGTH
CB_S-4-FUNCFAILSTK
CB_S-4-FUNCFAIL
CB_S-4-PARMOUTOFRANGE
CB_S-4-MALLOCFAILED
CB_S-4-OPENTRANSFAIL
CB_S-4-BINDTRANSFAIL
CB_S-4-RCVFRTRNSFAIL
CB_S-4-MSGSENDFAIL
CB_S-4-MSGRECVFAIL
CB_S-4-BADSRMSLOT
CB_S-4-BADCARDTYPE
CB_S-4-INVVARBIND
CB_S-4-SEMCREATEERR
CB_S-4-SEMTAKEERR
CB_S-4-SEMGIVEERR
CB_S-4-BUFTAKEERR
CB_S-4-FRMBUFTAKEERR
CB_S-7-TOOFEWVARBINDS
CB_S-7-NOTRAPS
CB_S-6-TRAPLOG_WRAP
CB_S-6-RPMPORTCLOSED
CB_S-4-RPMOPENPORT
CB_S-4-OPENPORT
CB_S-4-PROCESSDEQ
CB_S-4-CREATEWATCHEDQ
CB_S-4-CREATENAMEDPORT
CB_S-4-GETPAKMSGFAIL
CB_S-4-IPCSENDMSGFAIL
CB_S-4-MSG_TOO_SMALL
CB_S-4-SOIINITFAIL
CB_S-4-QUEUEINITFAIL
CB_S-5-MSG_DROPPED
CB_S-5-TRAP_DROPPED
CB_S-5-TRAPBADSTATE
CB_S-5-NONRTMTRAP
CB_S-4-UNKNOWNMSG
CB_S-4-CLONETRAPERR
CB_S-4-PROXYRATINITFAI
CB_S-4-PROXYRATMSGFAIL
CB_S-4-PROXYRATSTATEFA
CB_S-4-PROXYERRORMISC
CB_S-4-TRAPSENDFAIL
CB_S-6-TASK_ATTACH
DDTS "shm"
CBC-4-CBC_DRV_ERR1
CBC-4-CBC_DRV_ERR2
CBC-4-CBC_DRV_ERR3
CBC-4-CBC_DRV_ERR4
CBC-4-CBC_DRV_ERR
Error Messages for MGX and SES Release 4.0.00
These error messages (also called Events) are for MGX and SES, Release 4.0.00.
ACAR-2-SHLFINIT
SEVERITY: Major Alert
FORMAT: "MAJOR_ALERT ERROR: %s"
THROTTLING: No Throttling
EXPLANATION: "Task Initialization Error"
RECOMMENDED ACTION: Indicates an internal error detected by the PXM connection management module. It needs to be analyzed by TAC and possibly by the development team.
REQUIRED INFO: "Collect dsplog, dsperr, dspdbinfo 7 3 information"
ACAR-2-SHLFINIT_ENDPT
SEVERITY: Major Alert
FORMAT: "MAJOR_ALERT ERROR: %s %d"
THROTTLING: One Tick
EXPLANATION: "Task Initialization Error"
RECOMMENDED ACTION: Indicates an internal error detected by the PXM connection management module. It needs to be analyzed by TAC and possibly by the development team.
REQUIRED INFO: "Collect dsplog, dsperr information"
ACAR-2-DBINIT
SEVERITY: Major Alert
FORMAT: "Slot:%u Init Error: %s"
THROTTLING: No Throttling
EXPLANATION: "Slot Database Initialization Error"
RECOMMENDED ACTION: Indicates an internal error detected by the PXM connection management module. It needs to be analyzed by TAC and possibly by the development team.
REQUIRED INFO: " Collect dsplog, dsperr, dspdbinfo <slot> 3 information"
DDTS "pxm-connmgm"
CM_L-7-CM_LMI_NO_ALM_C
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Alarm info was not changed since last cycle"
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
CM_L-7-CM_LMI_INIT_SUC
SEVERITY: Information
FORMAT: "CmLmiInit Successful %s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "CmLmiInit Successful"
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
CM_L-4-CM_LMI_MEM_ERRO
SEVERITY: Error
FORMAT: "Memory allocation error, %s"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Failed to allocate memory-connection/alarm resync will be interrupted."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: Please capture the following information from the PXM45 cli and call your TAC support
1) dspcds/dspcd
2) dspver
3) dsplog -sl <slot which is experiencing the problem>
4) dsplog -sl < redundant slot if configured>
5) dsperr for the above slots.
6) Save the core file if required
CM_L-4-CM_LMI_ERR_GEN
SEVERITY: Error
FORMAT: "PIPC error on line %d rc %d errno %d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "pipcSend error. Data will not be sent to LSM"
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: Please capture the following information from the PXM45 cli and call your TAC support
1) dspcds/dspcd
2) dspver
3) dsplog -sl <slot which is experiencing the problem>
4) dsplog -sl < redundant slot if configured>
5) dsperr for the above slots.
6) Save the core file if required
CM_L-5-CM_LMI_ERR_SLOT
SEVERITY: Warning
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Failed to retreive slot info from pcPro"
RECOMMENDED ACTION: No action required
REQUIRED INFO: Please capture the following information from the PXM45 cli and call your TAC support
1) dspcds/dspcd
2) dspver
3) dsplog -sl <slot which is experiencing the problem>
4) dsplog -sl < redundant slot if configured>
5) dsperr for the above slots.
6) Save the core file if requireM_L-4-CM_LMI_ERR_SEND
SEVERITY: Error
FORMAT: "Send Message failed %s"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Error calling ssiMsgSend - Data will not be sent to LSM - will retry
SEVERITY: Error
FORMAT: "Initialization failure %s"
FLAG: No Flag
THROTTLING: One Tick
CM_L-2-CM_LMI_ERR_PORT
SEVERITY: Major Alert
FORMAT: "MAJOR_ALERT ERROR %s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Task Initailizeation error - system will not come up"
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: Please capture the following information from the PXM45 cli and call your TAC support
1) dspcds/dspcd
2) dspver
3) dsplog -sl <slot which is experiencing the problem>
4) dsplog -sl < redu
CM_L-4-CM_LMI_ERR_SEND
SEVERITY: Error
FORMAT: "Send Message failed: %s"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Error calling ssiMsgSend - Data will not be sent to LSM - will retry next periodic cycle"
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log, call
CM_L-4-CM_LMI_ERR_MSGQ
SEVERITY: Error
FORMAT: "Initialization failure: %s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Fail to bind message queue - CmLmiTask will not be able to receive messages - No connection/alarm resync will be performed"
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: Please capture the following information from the PXM45 cli and call your TAC support:
1) dspcds/dspcd
2) dspver
3) dsplog -sl <slot which is experiencing the problem>
4) dsplog -sl < redundant slot if configured>
5) dsperr for the above slots.
6) Save the core file if required
CM_L-5-CM_LMI_ERR_SET_
SEVERITY: Warning
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Unknown timeout event"
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: No Required Info
CM_L-4-CM_LMI_ERR_SCHE
SEVERITY: Error
FORMAT: "%s %d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Error Calling ssiScheduleTimeout - periodic conn/alarm resynch disabled"
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: Please capture the following information from the PXM45 cli and call your TAC support
1) dspcds/dspcd
2) dspver
3) dsplog -sl <slot which is experiencing the problem>
4) dsplog -sl < redundant slot if configured>
5) dsperr for the above slots.
6) Save the core file if required
CM_L-4-CM_LMI_CREATE_T
SEVERITY: Error
FORMAT: "Creating Synch Timer failure %s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Error Creating Synch Timer - periodic conn/alarm will not be initiated"
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: Please capture the following information from the PXM45 cli and call your TAC support
1) dspcds/dspcd
2) dspver
3) dsplog -sl <slot which is experiencing the problem>
4) dsplog -sl < redundant slot if configured>
5) dsperr for the above slots.
6) Save the core file if required
CM_L-5-CM_LMI_LSLOT_ER
SEVERITY: Warning
FORMAT: "Unable to get Lslot info line %d, logSlot %d, prim value %d sec value %d\n"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Error trying to access LSLOT INFO"
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: Please capture the following information from the PXM45 cli and call your TAC support
1) dspcds/dspcd
2) dspver
3) dsplog -sl <slot which is experiencing the problem>
4) dsplog -sl < redundant slot if configured>
5) dsperr for the above slots.
6) Save the core file if required
CM_L-5-CM_LMI_PSLOT_ER
SEVERITY: Warning
FORMAT: "Unable to get Pslot Info line %d phySlot %d errno %d\n"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Error trying to access PSLOT INFO"
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: Please capture the following information from the PXM45 cli and call your TAC support
1) dspcds/dspcd
2) dspver
3) dsplog -sl <slot which is experiencing the problem>
4) dsplog -sl < redundant slot if configured>
5) dsperr for the above slots.
6) Save the core file if required
DDTS "pxm-connmgm"
ACAR-2-SHLFINIT
SEVERITY: Major Alert
FORMAT: "MAJOR_ALERT ERROR %s"
FLAG: Stack Trace
THROTTLING: No Throttling
EXPLANATION: "Task Initialization Error"
RECOMMENDED ACTION: Indicates an internal error detected by the PXM connection management module. It needs to be analyzed by TAC and possibly by the development team.
REQUIRED INFO: "Collect dsplog, dsperr, dspdbinfo 7 3 information"
ACAR-2-SHLFINIT_ENDPT
SEVERITY: Major Alert
FORMAT: "MAJOR_ALERT ERROR %s %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Task Initialization Error"
RECOMMENDED ACTION: Indicates an internal error detected by the PXM connection management module. It needs to be analyzed by TAC and possibly by the development team.
REQUIRED INFO: "Collect dsplog, dsperr information"
ACAR-2-DBINIT
SEVERITY: Major Alert
FORMAT: "Slot%u Init Error %s"
FLAG: Stack Trace
THROTTLING: No Throttling
EXPLANATION: "Slot Database Initialization Error"
RECOMMENDED ACTION: Indicates an internal error detected by the PXM connection management module. It needs to be analyzed by TAC and possibly by the development team.
REQUIRED INFO: "Collect dsplog, dsperr, dspdbinfo <slot> 3 information"
ACAR-2-SMM_ERROR_GEN
SEVERITY: Major Alert
FORMAT: "Slot %d SM Error %s"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Service Module Configuration Upload/Download Error"
RECOMMENDED ACTION: Indicates an internal error detected by the PXM connection management module. It needs to be analyzed by TAC and possibly by the development team.
REQUIRED INFO: "Collect dsplog, dsperr information"
ACAR-4-MSG_PROC_ERR
SEVERITY: Error
FORMAT: "Slot %d Msg Proc Error %s errno 0x%x"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "General Message Processing Error"
RECOMMENDED ACTION: Indicates an internal error detected by the PXM connection management module. It needs to be analyzed by TAC and possibly by the development team.
REQUIRED INFO: "Collect dsplog, dsperr information"
ACAR-4-CHK_ERR
SEVERITY: Error
FORMAT: "Slot %d Check failed for Argument %s = %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Check Failed for logged parameters"
RECOMMENDED ACTION: Indicates an internal error detected by the PXM connection management module. It needs to be analyzed by TAC and possibly by the development team.
REQUIRED INFO: "Collect dsplog, dsperr information"
ACAR-7-INFO_LOG
SEVERITY: Information
FORMAT: "Information Log %s Slot %d Card Type %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Informational Log"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
DDTS "shm"
RED-7-DETECT_MISMATCH
SEVERITY: Information
FORMAT: "Detect mismatch: slot %d, version = %d, redType = %d, cd_type = %d (%d), redFeature = %d (%d)"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Detect mismatch on slot from tRed"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-7-MSG_DATA_ERROR
SEVERITY: Information
FORMAT: "msg data err %s"
FLAG: No Flag
THROTTLING: One Second
EXPLANATION: "Message error. Data Errors and Unknown Msgs."
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-AC_SEND_MSG_ERR
SEVERITY: Information
FORMAT: "Could not send MSG to SM %s, slot %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Auto Card send message failed error."
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-AC_GEN_ERR
SEVERITY: Information
FORMAT: "General ERROR %s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Auto Card PMM related failure / Bram related failure. "
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-4-NACK_ERR
SEVERITY: Error
FORMAT: "%s %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Received a NACK from the SM. SM will be put to FAILED state"
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: Enter the CLI commands dspcds, dspcd (for PXM and for the slot the error is found), dspver, dsperr, ls C:/FW before calling the Cisco Techincal support representative.
RED-7-AC_INFO_ERR
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Informational Event"
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-TBL_UPD_INFO
SEVERITY: Information
FORMAT: "tRed INFO In %s at %u, %s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "tRed is updating redTable (lsmRedDb in SHM)."
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-AC_SWITCHCARD_I
SEVERITY: Information
FORMAT: "Info, %s, From Slot=%d, To Slot = %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Autocard switch card event."
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-AC_MEM_ERR
SEVERITY: Information
FORMAT: "Memory error in system %s"
FLAG: Stack Trace
THROTTLING: One Second
EXPLANATION: "Auto Card memory error."
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-AC_TIME_OUT_ERR
SEVERITY: Information
FORMAT: "State Time out %s"
FLAG: Stack Trace
THROTTLING: One Second
EXPLANATION: "Auto Card time out error."
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-AC_WRNGMSG_ERR
SEVERITY: Information
FORMAT: "ACRED Wrong msg rcvd %s"
FLAG: No Flag
THROTTLING: One Second
EXPLANATION: "Auto Card wrong message type error."
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-AC_DWNLBRAMERR
SEVERITY: Information
FORMAT: "ACRED Download BRAM Failed %s"
FLAG: Stack Trace
THROTTLING: One Second
EXPLANATION: "BRAM download error."
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-AC_UPLDBRAMERR
SEVERITY: Information
FORMAT: "ACRED Upload BRAM Failed %s , slot %d"
FLAG: Stack Trace
THROTTLING: One Second
EXPLANATION: "BRAM upload error."
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-BADARCERR
SEVERITY: Information
FORMAT: "%s BAD Archive from slot %d."
FLAG: No Flag
THROTTLING: One Second
EXPLANATION: "SM received a Bad configuration file."
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-SMM_ERROR_GEN
SEVERITY: Information
FORMAT: "General Error %s"
FLAG: Stack Trace
THROTTLING: One Second
EXPLANATION: "General system error."
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-SMM_INFO
SEVERITY: Information
FORMAT: "System Information %s"
FLAG: No Flag
THROTTLING: One Second
EXPLANATION: "System Information."
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-SMM_GEN_ERR
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "System Information."
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-BAD_SHLF_SLOT
SEVERITY: Information
FORMAT: "Bad shelf slot num %s"
FLAG: No Flag
THROTTLING: One Second
EXPLANATION: "SMM bad shelf slot."
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-RAM_SYNC_IOV_FA
SEVERITY: Information
FORMAT: "Call to %s returned error, ramDbId=0x%x"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "tRed Ram Sync message create and sending errors"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-7-RAM_SYNC_IOV_SE
SEVERITY: Information
FORMAT: "Call to %s returned error, errno = %d, %s 0x%x"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "tRed Ram Sync message send failed due to errrno"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-4-MSGQ_BIND_FAIL
SEVERITY: Error
FORMAT: "ssiMsgQBind FAILED"
FLAG: Write to Bram
THROTTLING: One Tick
EXPLANATION: "tRed task could not Bind to the Message Queue. This could cause tRed to not be able to receive any messages"
RECOMMENDED ACTION: "Collect information specified in REQUIRED_INFO field and call TAC"
REQUIRED INFO: "Collect hot core dump, event logs and errors"
RED-4-IPC_COM_EPID_FA
SEVERITY: Error
FORMAT: "%s returned %d, errno %d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "tRed task could not create IPC Comm epid. Due to this tRed will not be able to receive or send IPC messages."
RECOMMENDED ACTION: "Collect information specified in REQUIRED_INFO field and call TAC"
REQUIRED INFO: "Collect hot core dump, event logs and errors"
RED-4-PIPC_PORT_CREAT
SEVERITY: Error
FORMAT: "pipcPortCreate Failed , return code = %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "tRed task could not create pipc port. Due to this tRed will not be able to send of received pipc messages"
RECOMMENDED ACTION: "Collect information mentioned in REQUIRE_INFO feild and call TAC"
REQUIRED INFO: "Collect hot core dump, event logs and errors"
RED-4-INIT_TBL_FAILED
SEVERITY: Error
FORMAT: "%s Failed to initialize "
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "tRed task could not Initialize its database"
RECOMMENDED ACTION: "Collect the info in the REQUIRED_INFO field and call TAC"
REQUIRED INFO: "Collect a hot core dump, the event logs and err logs"
RED-7-SM_MSG_RCVD
SEVERITY: Information
FORMAT: "Received event %s from slot %d "
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "tRed received an event from the SM"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-6-AC_INCORRECT_ST
SEVERITY: Notice
FORMAT: "Slot %d, Current state %d, expected state %d "
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "tRed cannot process event as the expected state is different than the actual state"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-6-AC_INVALID_MSG
SEVERITY: Notice
FORMAT: "Slot %d, Msg type %x, srcId %d "
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Invalid message obtained by tRed "
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-4-DOWNLOAD_FAILED
SEVERITY: Error
FORMAT: "Slot %d, %s returned %d "
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "tRed was not able to download the image to the sm "
RECOMMENDED ACTION: "Collect the info mentioned in REQUIRED_INFO and observe the card state"
REQUIRED INFO: "Collect the logs and error"
RED-7-DOWNLOAD_PASSED
SEVERITY: Information
FORMAT: "Slot %d, Download passed "
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "tRed was able to download the image to the sm "
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-7-PMM_MSG_RCVD
SEVERITY: Information
FORMAT: "Received event %s from slot %d cardState = %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "tRed received a PMM event "
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-4-CD_STATE_MISMAT
SEVERITY: Error
FORMAT: "Slot %d,cd state set to Mismatch.%s"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "tRed card state changed to mismatch. The card will now be in the mismatch state"
RECOMMENDED ACTION: "Collect the logs and check the reason for mismatch and call TAC"
REQUIRED INFO: "Collect the dsplog and dsperr output"
RED-7-PMM_EVENT_SET
SEVERITY: Information
FORMAT: "PMM event %d set for slot %d, card state = %d "
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "PMM event is set based on the card state by tRed"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-7-SM_STATE_EVENT
SEVERITY: Information
FORMAT: "PMM event %d set for slot %d, card state = %d "
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "PMM event is set based on the card state by tRed"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-5-SM_STATE_CHANGE
SEVERITY: Warning
FORMAT: "pSlot = %d, Current State = %d, Event received =%d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "SM state is changed based on the event received"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-7-SM_INVALID_EVEN
SEVERITY: Information
FORMAT: "Invalid event %d received,pSlot = %d,State = %d,"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Invalid event received by tRed for the current SM state"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-5-SEND_MISMATCH_M
SEVERITY: Warning
FORMAT: "%s. slot %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Send mismatch message to the slot from tRed"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-5-IPC_MSG_RVC_ERR
SEVERITY: Warning
FORMAT: "IPC message receive error, errno = %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Error is receiving IPC message"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-5-SSI_RCVID_ERROR
SEVERITY: Warning
FORMAT: "ssi rcvid is NULL"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "ssi receive ID is Null"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-5-IPC_MSG_ALLOC_F
SEVERITY: Warning
FORMAT: "ssi ipc message allocation failed"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "ssi ipc message allocation failed"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-5-IPC_MSG_REPLY_F
SEVERITY: Warning
FORMAT: "ssi ipc message reply failed, errno = %d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "failed to obtain the message reply throug ipc"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-5-CLI_INVALID_PAR
SEVERITY: Warning
FORMAT: "%s invalid command type %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Invalid parameters passed to the tRed cli api"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-5-CLI_NULL_PARAM
SEVERITY: Warning
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Invalid parameters passed to the tRed cli api"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-5-IPC_MSG_SEND_FA
SEVERITY: Warning
FORMAT: "ipc message send failed, errno = %d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "the ipc message send api returned and error and thus the message was not sent across to the recipient"
RECOMMENDED ACTION: "Collect the info mentioned in the REQUIRED_INFO field"
REQUIRED INFO: "Collect the hot core dump, the dsplog output and the dsperr output."
RED-5-IPC_DATAPTR_NUL
SEVERITY: Warning
FORMAT: "%d, Null data pointer received from ssi"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Null data pointer was recevied by the task from ssi"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-4-RED_CMD_MISMATC
SEVERITY: Error
FORMAT: "%s expected %d, received %d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "mismatch between the expected command response and the command response actually received"
RECOMMENDED ACTION: "Collect the info mentioned in REQUIRED_INFO and call TAC"
REQUIRED INFO: "Collect the dsplog and dsperr outputs"
RED-7-INV_CLI_CMD
SEVERITY: Information
FORMAT: "Invalid command type received %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Invalid command type received by tRed from cli"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-5-FW_UPGD_FAIL
SEVERITY: Warning
FORMAT: "%s slot %d, link state %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Firware upgrade failed for the slot as the slot was in redundancy and not meeting the loadrev criteria"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-5-CTC_INV_EVENT
SEVERITY: Warning
FORMAT: "Invalid CTC event received %d by tRed"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Invalid CTC event received by tRed"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
RED-4-CD_REMOVED
SEVERITY: Error
FORMAT: "card in slot %d removed , state = %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "tRed recevied an event that card is removed"
RECOMMENDED ACTION: "No action required. This event flags a removal of a card in the slot."
REQUIRED INFO: No Required Info
RED-4-CD_FAILED
SEVERITY: Error
FORMAT: "card in slot %d failed , state = %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "tRed recevied an event that card has failed"
RECOMMENDED ACTION: "Collect the info mentioned in REQUIRED_INFO and call TAC"
REQUIRED INFO: "Collect the hot core dump, the dsplog output and the dsperr output."
RED-7-AC_ADDRED_INFO
SEVERITY: Information
FORMAT: " %s, Pri Slot=%d,Sec Slot = %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "addred event information"
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-AC_DELRED_INFO
SEVERITY: Information
FORMAT: " %s, Pri Slot=%d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "delred event information"
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-CD_STATE_INFO
SEVERITY: Information
FORMAT: " %s, Slot=%d, state = %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "tRed card state set"
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-PRIMARY_NOT_PRO
SEVERITY: Information
FORMAT: " %s,primSlot=%d, secSlot = %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Primary slot not protected by secondary slot"
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-SEC_CD_INFO
SEVERITY: Information
FORMAT: " %s, red type =%d, state = %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Setting the Secondary card state"
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-LINEMODULE_INFO
SEVERITY: Information
FORMAT: " %s,Slot %d,linemodule type=%d,red type = %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Line modules info logged byt tRed"
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-AC_MIB_MISMATCH
SEVERITY: Information
FORMAT: " MIB mismatch detected. state = %d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "MIB mismatch detected by autocard"
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-DWLD_INFO
SEVERITY: Information
FORMAT: "%s slot %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "tRed download task info"
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-5-DWLD_FOPEN_FAIL
SEVERITY: Warning
FORMAT: "%s slot %d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "tRed download task file open failed"
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-4-DWLD_FAILED
SEVERITY: Error
FORMAT: "%s slot %d, download type %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "tRed download task failed for the slot. The card will be reset."
RECOMMENDED ACTION: "Collect information mentioned in the REQUIRED_INFO field and call TAC."
REQUIRED INFO: "Collect the dsplog and dsperr outputs."
RED-4-AC_INIT_FAIL
SEVERITY: Error
FORMAT: "%s, err %d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "The Initialization of the tRed task failed due to tthe displayed error"
RECOMMENDED ACTION: "Collect the information mentioned in REQUIRED_INFO and call TAC"
REQUIRED INFO: "Collect a hot core dump, the dsplog output and the dsperr output."
RED-5-AC_INIT_ERR
SEVERITY: Warning
FORMAT: "%s, err %d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "The Initialization of the tRed task had an error due to tthe displayed warning"
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-AC_INIT_INFO
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Information regarding tRed Initialization"
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-REDUNDANCY_INFO
SEVERITY: Information
FORMAT: "%s, slot %d "
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Information regarding tRed redundancy"
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-4-PMM_CD_RESET
SEVERITY: Error
FORMAT: "reseting slot %d, err %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "tRed is reseting the service module"
RECOMMENDED ACTION: "No action required. This event is logged when tREd resets a card."
REQUIRED INFO: No Required Info
RED-5-SM_INSERT_MSG
SEVERITY: Warning
FORMAT: "SM insertion message received. slot %d, state %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "SM insertion message received by tRed for the slot"
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-4-SM_FAILED_MSG
SEVERITY: Error
FORMAT: "SM failed message received. slot %d, state %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "SM failed message received by tRed for the slot"
RECOMMENDED ACTION: "Collect the information mentioned in the REQUIRED_INFO field and call TAC"
REQUIRED INFO: "Collect the hot core dump, the dsplog output and the dsperr output."
RED-4-SM_MISMATCH_MSG
SEVERITY: Error
FORMAT: "SM mismatch message received. slot %d, state %d"
FLAG: No Flag
THROTTLING: One Second
EXPLANATION: "SM mismatch message received by tRed for the slot"
RECOMMENDED ACTION: "Collect the information mentioned in the REQUIRED_INFO field and call TAC."
REQUIRED INFO: "Collect the hot core dump, the dsplog output and the dsperr output."
RED-4-SM_REMOVED_MSG
SEVERITY: Error
FORMAT: "SM removed message received. slot %d, state %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "SM removed message received by tRed for the slot"
RECOMMENDED ACTION: "No action required."
REQUIRED INFO: No Required Info
RED-7-CARD_FAIL_INFO
SEVERITY: Information
FORMAT: "%s%d"
FLAG: No Flag
THROTTLING: One Second
EXPLANATION: "Primary or Secondary Card Failed"
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
RED-7-SHM_MSGRCV
SEVERITY: Information
FORMAT: "%s %s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Message received by tRed from the SHM"
RECOMMENDED ACTION: "No action required."
REQUIRED INFO: No Required Info
RED-7-CMD_FAILED
SEVERITY: Information
FORMAT: "%s %s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "tRed command failed"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
DDTS "alarms"
CAMA-5-INVALIDINPUT
SEVERITY: Warning
FORMAT: "One of the inputs to the function %s() was invalid."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "API Software Error. The parameter value for one of the parameters passed in as an argument to the named function was invalid."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CAMA-5-PARMOUTOFTRANGE
SEVERITY: Warning
FORMAT: "Parm %s is out of range. The range is between %d and %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "API Software Error. The parameter value for the named parameter is out of range."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CAMA-5-PARMINVALID
SEVERITY: Warning
FORMAT: "Parm %s value '0x%x' is invalid to %s."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "API Software Error. The parameter value for the named parameter passed in as an argument to the named function was invalid."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CAMA-5-PARMINVLENGTH
SEVERITY: Warning
FORMAT: "Parm %s invalid length of %d to %s. Max=%d Value='%s'"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "API Software Error. The named paramater passed in as an argument to the named function either had a length of zero or exceeded the maximum value specified."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CAMA-5-FUNCFAIL_STKDUM
SEVERITY: Warning
FORMAT: "%s() SNMP subsystem call to %s() failed. rc=%d."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "The specified function call failed. It failed with the specified return code. A stack trace was generated."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CAMA-5-QUEUEFULL
SEVERITY: Warning
FORMAT: "Could not send Alarm Summary %d from slotnum %d."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "The CAM Client Queue has reached the high water mark"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
DDTS "unknown"
AUPL-5-INVD_INPT
SEVERITY: Warning
FORMAT: "%s %s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Invalid input obtained from the NMS station. For example error could be due to invalid slot number specified, etc"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
AUPL-4-INVD_RET
SEVERITY: Error
FORMAT: "%s %s"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Invalid Return code obtained from the APIs involved in transporting the file (eg due to response failure from SM etc)"
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the natur of the error. Do the same with 'dsplog' command. If you cannot determine the nature of the error from the error message text or from the 'dsperr'/'dsplog' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "Please collect the output of CLIs dspver, dspcds, dsplog, dsperr"
AUPL-4-INVD_VAL
SEVERITY: Error
FORMAT: "%s %s %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Invalid value computed eg for the ftp handler This could indicate a memory corruption in some cases"
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "Please collect the output of CLIs dspver, dspcds, dsplog"
AUPL-4-INVD_STR
SEVERITY: Error
FORMAT: "%s %s %s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Invalid string obtained as input from the NMS station. For example error could be due to invalid filename specified, etc"
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "Please collect the output of CLIs dspver, dspcds, dsplog"
AUPL-4-INVD_INPT
SEVERITY: Error
FORMAT: "%s %s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Invalid input obtained from the NMS station. For example error could be due to invalid slot number specified, etc"
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "Please collect the output of CLIs dspver, dspcds, dsplog"
AUPL-4-INVD_RET
SEVERITY: Error
FORMAT: "%s %s"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Invalid return code obtained from the APIs eg APIs involved in installing the pseudo-driver"
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the natur of the error. Do the same with 'dsplog' command. If you cannot determine the nature of the error from the error message text or from the 'dsperr'/'dsplog' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "Please collect the output of CLIs dspver, dspcds, dsplog, dsperr"
AUPL-4-INVD_VAL
SEVERITY: Error
FORMAT: "%s %s %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Invalid value computed eg flag for driver installation This could indicate a memory corruption in some cases"
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "Please collect the output of CLIs dspver, dspcds, dsplog"
AUPL-4-INCRT_CALL
SEVERITY: Error
FORMAT: "%s %s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Incorrect action by NMS stations eg attempt to write to a file etc"
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "Please collect the output of CLIs dspver, dspcds, dsplog"
DDTS "axsm_apps"
APS-4-APS_MAIN_ERR
SEVERITY: Error
FORMAT: "APS Error Work Line index %s function 0X%X line %d exit due to major %d minor %d error"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Indicates an internal error detected by APS application in the main module. It needs to be analyzed by TAC and possibly by the APS development team. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "No information required. "
APS-4-APS_MUX_ERR
SEVERITY: Error
FORMAT: "APS Error Work Line index %s function 0X%X line %d exit due to major %d minor %d error"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "This error indicates failure to update the APS backcard mux register. This could lead to incorrect behaviour of the APS line pair. It needs to be further analyzed by TAC and possibly by development team. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-INIT_ERR
SEVERITY: Error
FORMAT: "APS Error Work Line index %s function 0X%X line %d exit due to major %d minor %d error"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "This error indicates failure to create a task during the task initialisation sequence. This could lead to incorrect behaviour of APS module. It needs to be further analyzed by TAC and possibly from SSI team. In normal operation, such an error should never get reported"
RECOMMENDED ACTION: "Contact SSI team, review SSI eventlog to see failure reason. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-APS_MSG_ERR
SEVERITY: Error
FORMAT: "APS Error Slot Num %d function 0X%X line %d exit due to major %d minor %d error"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "This error indicates failure to initialise message handler. This could lead to incorrect behaviour of APS module. It needs to be further analyzed by TAC and possibly from SSI team. In normal operation, such an error should never get reported"
RECOMMENDED ACTION: "Contact SSI team, review SSI eventlog to see failure reason."
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-APS_IPC_COMEP_C
SEVERITY: Error
FORMAT: "APS ErrorCard %d function 0X%X line %d IPC com endpoint create failed major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "This corresponds to ssiIpcComEpUnbind failure. This could lead to incorrect behaviour of APS module. It needs to be further analyzed by TAC and possibly from SSI team. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "Contact SSI team, review SSI eventlog to see failure reason. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-APS_IPC_COMEP_U
SEVERITY: Error
FORMAT: "APS ErrorCard %d function 0X%X line %d IPC ComEp unbind send failed major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "This correspnods to ssiIpcComEpUnbind failure. This could lead to incorrect behaviour of APS module. It needs to be further analyzed by TAC and possibly from SSI team. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "Contact SSI team, review SSI eventlog to see failure reason. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-APS_IPC_COMEP_N
SEVERITY: Error
FORMAT: "APS ErrorCard %d function 0X%X line %d IPC ComEp namebind send failed major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "This corresponds to ssiIpcComEpNameBind failure. This could lead to incorrect behaviour of APS module. It needs to be further analyzed by TAC and possibly from SSI team. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "Contact SSI team, review SSI eventlog to see failure reason. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-APS_IPC_MSG_SEN
SEVERITY: Error
FORMAT: "APS ErrorCard %d function 0X%X line %d IPC Msg send failed major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "This corresponds to ssiIpcMessageSend failure. This could lead to incorrect behaviour of APS module. It needs to be further analyzed by TAC and possibly from SSI team. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "Contact SSI team, review SSI eventlog to see failure reason. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-APS_IPC_MSG_ALL
SEVERITY: Error
FORMAT: "APS ErrorCard %d function 0X%X line %d IPC Msg alloc failed major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS could not allocated memory for a message. This could lead to incorrect behaviour of APS module. It needs to be further analysed by TAC and possibly from SSI team. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "Contact SSI team, review SSI eventlog to see failure reason. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-APS_EM_REPORT_F
SEVERITY: Error
FORMAT: "APS ErrorCard %d function 0X%X line %d EM Root report failed major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "EM could not be informed of EMROOT_INIT_DONE. emRootReportDone failed"
RECOMMENDED ACTION: "Contact SSI team to review send failure reason."
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-APS_MSG_HNDLR_I
SEVERITY: Error
FORMAT: "APS ErrorCard %d function 0X%X line %d Msg Handler init failed major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Card Task Msg handler init Failed. This could lead to incorrect behaviour of APS module. It needs to be further analyzed by TAC and possibly from SSI team. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "Contact SSI team, review SSI eventlog to see failure reason."
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-APS_RMI_SEND_FA
SEVERITY: Error
FORMAT: "APS Error Card %d function 0X%X line %d RMI send purge failed major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Corresponds to ssiRmiRmtEpidCtxtPurge failure. This could lead to incorrect behaviour of APS module. It needs to be further analyzed by TAC and possibly from RMI team. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "Contact RMI team, review RMI eventlog to see failure reason. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-APS_RMI_CTXT_PU
SEVERITY: Error
FORMAT: "APS Error Card %d function 0X%X line %d RMIctxt purge failed major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Corresponds to ssiRmiRmtEpidCtxtPurge failure. This could lead to incorrect behaviour of APS module. It needs to be further analyzed by TAC and possibly from RMI team. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "Contact RMI team, review RMI eventlog to see failure reason. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-APS_RMI_USER_AC
SEVERITY: Error
FORMAT: "APS Error Card %d function 0X%X line %d RMI user ack data send failed major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "ssiRmiUsrAckedDataAck send failed. This could lead to incorrect behaviour of APS module. It needs to be further analyzed by TAC and possibly from RMI team. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "Contact RMI team, review RMI eventlog to see failure reason. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-APS_RMI_ACKDATA
SEVERITY: Error
FORMAT: "APS Error Card %d function 0X%X line %d RMI ack data send failed major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "ssiRmiAckedDataSendAndReset failed. This could lead to incorrect behaviour of APS module. It needs to be further analyzed by TAC and possibly from RMI team. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "Contact RMI team, review RMI eventlog to see failure reason. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-APS_RMI_MSG_ALL
SEVERITY: Error
FORMAT: "APS Error Card %d function 0X%X line %d RMI Msg Alloc failed major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "ssiRmiMsgAllocate failed. This could lead to incorrect behaviour of APS module. It needs to be further analyzed by TAC and possibly from RMI team. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "Contact RMI team, review RMI eventlog to see failure reason. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-APS_INVALID_CAR
SEVERITY: Error
FORMAT: "APS Error Card %d function 0X%X line %d Invalid Card Event major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Invalid Card Event message recived by APS task. PHY task has reported a card event which is neither UP nor DOWN. Please check the eventlog for error type. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of following shell command on Active AXSM card.
a) ApsDisplayEventTraceLineId 0,0,0 "
APS-4-APS_RMI_LINE_PA
SEVERITY: Error
FORMAT: "APS Error Card %d function 0X%X line %d RMI line pair cntxt sync failed major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Context Sync to line pair failed. This could lead to incorrect behaviour of APS module. It needs to be further analyzed by TAC and possibly from SSI team. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-APS_RMI_UNACK_D
SEVERITY: Error
FORMAT: "APS Error Card %d function 0X%X line %d RMI unack data send failed major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "ssiRmiUnackedDataSend failed. This could lead to incorrect behaviour of APS module. It needs to be further analyzed by TAC and possibly from SSI team. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-APS_RMI_SYNC_DA
SEVERITY: Error
FORMAT: "APS Error Card %d function 0X%X line %d RMI sync data send failed major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "ssiRmiSyncDataSend failed. This could lead to incorrect behaviour of APS module. It needs to be further analyzed by TAC and possibly from SSI team. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-APS_RMI_RMT_EPI
SEVERITY: Error
FORMAT: "APS Error Card %d function 0X%X line %d RMI remote epid create failed major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "ssiRmiRmtEpidCtxtCreate failed. This could lead to incorrect behaviour of APS module. It needs to be further analyzed by TAC and possibly from RMI team. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "Contact RMI team, review RMI eventlog to see failure reason."
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-APS_UNKNOWN_MSG
SEVERITY: Error
FORMAT: "APS Error Card %d function 0X%X line %d Unknwon Message recd. major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Unknown message reveived by APS card task for relaying to the peer card."
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "No information required. "
APS-4-RMI_UNACK_DATAS
SEVERITY: Error
FORMAT: "APS Error Card %d function 0X%X line %d RMI unAckdata send failed major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "ssiRmiUnackedDataSend failed. This could lead to incorrect behaviour of APS module. It needs to be further analyzed by TAC and possibly from RMI team. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-APS_RMI_PORT_CR
SEVERITY: Error
FORMAT: "APS Error Card %d function 0X%X line %d RMI port create failed major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "ssiRmiPortCreate failed ie. APS task failed to create inter-card RMI port for communication. This would cause no communication between Active and Standby card. It needs to be further analyzed by TAC and possibly from RMI team. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-APS_INVALID_EPI
SEVERITY: Error
FORMAT: "APS Error Card %d function 0X%X line %d Invalid EPID major %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Invalid EPID. IPC endpoint-id is not initialised."
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "No information required. "
APS-4-APS_INVALID_CTC
SEVERITY: Error
FORMAT: "APS Error Card %d function 0X%X line %d Invalid CTC card role %d minor %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Invalid CTC card role. Card role is neither ACTIVE nor STAND-BY. "
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of following CLI commands On PXM45
a) dspcd <slot-id of the PRIMARY AXSM card>
b) dspcd <slot-id of the SECONDARY AXSM card if redundancy configured> "
APS-4-APS_RMT_BKCD_DE
SEVERITY: Error
FORMAT: "APS Error Card index %s function 0X%X line %d Back Card presence detect failed %d %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Back card or mini back plane not installed properly"
RECOMMENDED ACTION: "Remove and reinsert the backcards / minibackplane"
REQUIRED INFO: "Capture the output of 'dspapsbkplane' on ACTIVE and STANDBY card"
APS-4-APS_RMT_FRONTCD
SEVERITY: Error
FORMAT: "APS Error Card %d function 0X%X line %d Remote Front card presence detect failed Check Front Cd/MiniBackplane %d %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Back card or mini back plane not installed properly"
RECOMMENDED ACTION: "Remove and reinsert the backcards / minibackplane"
REQUIRED INFO: "Capture the output of 'dspapsbkplane' on ACTIVE and STANDBY card"
APS-4-APS_INVALID_CTC
SEVERITY: Error
FORMAT: "APS Error Card index %d function 0X%X line %d Invalid CTC cd role %d %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "LinePairTask detected invalide CTC Card role. Card role is neither ACTIVE nor STAND-BY."
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "Capture the output of following CLI commands On PXM45
a) dspcd <slot-id of the PRIMARY AXSM card>
b) dspcd <slot-id of the SECONDARY AXSM card if redundancy configured> "
APS-7-APS_AISL_DECL
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d AISL exists on Line index%s CHMM/PSBF not detected or cleared TXK1K2RxK1K2 0x%x"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "AISL exists. Channel Mismatch/PSBF will not be processed"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_PRDI
SEVERITY: Information
FORMAT: "APS Event Work Line index %s P_RDI is %s for both the lines "
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Enable/Disable P_RDI generation"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_SF_DECL
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d SF declared TXK1K2RxK1K2 0x%x"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "SF declared on the line"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_SELECTOR_RE
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d Selector Released TXK1K2RxK1K2 0x%x"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS selector state released"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_PROT_LINE_S
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d Protection LineSelected State TXK1K2RXK1K2 0x%x"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS selector state protection line selected"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_BRIDGE_RELE
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d Bridge Released State TXK1K2RxK1K2 0x%x"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS bridge state released"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_WORKCHAN_BR
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d Working Channel Bridged State TXK1K2RxK1K2 0x%x"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS working channel bridged"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_TXK1
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d TxK1 set TXK1K2RxK1K2 0x%x"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS TXK1 set to a new value"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_TXK2
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d TxK2 set TXK1K2RxK1K2 0x%x"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS TXK2 set to a new value"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_RXK1
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d RxK1 changed TXK1K2RxK1K2 0x%x"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS RXK1 changed"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_RXK2
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d RxK2 changed TXK1K2RxK1K2 0x%x"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS RXK2 changed"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_PROVISION
SEVERITY: Information
FORMAT: "APS Event Work Line %s function 0X%X line %d APS line pair provisioned. Protection Line %s Architecture %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS line pair is provisioned"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_DELETE
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d APS line pair deleted. Prot Line index %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS line pair is deleted"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_CONFIG_SF_B
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d config changeSF BER changed from 1E-%d to 1E-%d "
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS SF BER configuration changed"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_CONFIG_SD_B
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d config changeSD BER changed from 1E-%d to 1E-%d "
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS SD BER configuration changed"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_CONFIG_WTR
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d config changeWTR changed from %d to %d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS WTR value changed"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_CONFIG_DIR
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d config direction changed to %s, TXK1K2RxK1K2 0x%x"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS line pair mode, direction changed"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_CONFIG_REV
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d APS line pair config mode changed to %s, TXK1K2RxK1K2 0x%x"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS line pair revertive/non-revertive config changed"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_USER_SWITCH
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d user switch request switchOption %d service switch %d\n"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS user switch request. Could be Clear, Forced or Manual switch Working to Protection, Forced or Manual switch protection to working, service switch"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_PSB_INVALCH
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d PSB invalid channel TXK1K2RxK1K2 0x%x minor 0x%x"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Protection Switching Byte defect was detected due to an invalid channel."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_PSB_INVALCO
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d PSB invalid code TXK1K2RxK1K2 0x%x minor 0x%x"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Protection Switching Byte defect was detected due to an unused code."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_PSB_INCONSB
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d PSB inconsistent Byte TXK1K2RxK1K2 0x%x minor 0x%x"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Protection Switching Byte defect was detected due to an Inconsistent byte in the recd. K1."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_PSB_IRRELEV
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d PSB irrelevant request TXK1K2RxK1K2 0x%x minor 0x%x"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Protection Switching Byte defect was detected due to an Irrelevant request in the recd. K1."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_PSB_FAILURE
SEVERITY: Information
FORMAT: "APS Event Work Line index %s function 0X%X line %d PSBF declared TXK1K2RxK1K2 0x%x"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Protection Switching Byte Failue declared"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_PSBF_CLEARE
SEVERITY: Information
FORMAT: "APS Error Work Line index %s function 0X%X line %d PSBF is cleared TXK1K2RxK1K2 0x%x"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "PSBF has been Cleared"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_CHMM_CLEARE
SEVERITY: Information
FORMAT: "APS Error Work Line index %s function 0X%X line %d Channel Missmatch cleared TXRXK1K2 0x%x "
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Channel mismatch Failure Cleared."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-6-ADD_LN
SEVERITY: Notice
FORMAT: "APS Line Redundancy added with Work Line = %d.%d.%d, Prot Line = %d.%d.%d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Line Added. The event log would show the working and protection line indices. "
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-6-DEL_LN
SEVERITY: Notice
FORMAT: "APS Line Redundancy deleted with Work Line = %d.%d.%d , Prot Line = %d.%d.%d"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Line Pair deleted. The event log would show working and protection line indices."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-3-SW_CLEAR
SEVERITY: Minor Alert
FORMAT: "User Requested APS Clear successful workLN %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Clear Switch happened due to User Initiated Request. "
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "No information required. "
APS-3-SW_LOCK
SEVERITY: Minor Alert
FORMAT: "User Requested APS Lockout successful workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Line Lockout happened due to User Initiated Request. "
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "No information required. "
APS-3-SW_FORCE_WTOP
SEVERITY: Minor Alert
FORMAT: "User Requested APS Forced Work->Prot successful workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Line Forced W->P Switch happened due to User Initiated Request. "
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "No information required. "
APS-3-SW_FORCE_PTOW
SEVERITY: Minor Alert
FORMAT: "User Requested APS Forced Prot->Work successful workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Line Forced P->W Switch happened due to User Initiated Request. "
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "No information required. "
APS-3-SW_MAN_WTOP
SEVERITY: Minor Alert
FORMAT: "User Requested APS Manual Work->Prot successful workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Line Manual W->P Switch happened due to User Initiated Request. "
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "No information required. "
APS-3-SW_MAN_PTOW
SEVERITY: Minor Alert
FORMAT: "User Requested APS Manual Prot->Work successful workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Line Manual P->W Switch happened due to User Initiated Request. "
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "No information required. "
APS-2-PSB_FAIL
SEVERITY: Major Alert
FORMAT: "APS Protection Switch Byte Failure workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Protection Switching Byte Failure occured."
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsplog -sl <other slot in the pair if redundancy is configured> -mod APS
On each AXSM card, at both ends of the APS line
a) dspver
b) dspapsbkplane - for intercard APS setup only. Capture output
on Active and Standby cards.
c) dspapsln <the line mentioned in the eventlog>
d) dspalm -sonet <line mentioned in the eventlog>
e) dspbecnt <line mentioned in the eventlog>
Capture the output of following shell command on Active and Standby AXSM cards ApsDisplayEventTraceLineId <slot-id> <0-based baynum>
APS-2-CHAN_MISMATCH
SEVERITY: Major Alert
FORMAT: "APS Channel Mismatch workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Channel Mismatch Failure occured. Channel-id received in RxK2 is different than the channel-id in TxK1"
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsplog -sl <other slot in the pair if redundancy is configured> -mod APS
On each AXSM card, at both ends of the APS line
a) dspver
b) dspapsbkplane - for intercard APS setup only. Capture output
on Active and Standby cards.
c) dspapsln <the line mentioned in the eventlog>
d) dspalm -sonet <line mentioned in the eventlog>
e) dspbecnt <line mentioned in the eventlog>
Capture the output of following shell command on Active and Standby AXSM cards ApsDisplayEventTraceLineId <slot-id> <0-based baynum>
APS-2-PRIM_SEC_MISMAT
SEVERITY: Major Alert
FORMAT: "APS Primary Section Mismatch workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Primary Section Mismatch Failure occured. Section-id received in RxK2 is different than the Section-id in TxK2"
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsplog -sl <other slot in the pair if redundancy is configured> -mod APS
On each AXSM card, at both ends of the APS line
a) dspver
b) dspapsbkplane - for intercard APS setup only. Capture output
on Active and Standby cards.
c) dspapsln <the line mentioned in the eventlog>
d) dspalm -sonet <line mentioned in the eventlog>
e) dspbecnt <line mentioned in the eventlog>
Capture the output of following shell command on Active and Standby AXSM cards ApsDisplayEventTraceLineId <slot-id> <0-based baynum>
APS-6-CNF_SFBER
SEVERITY: Notice
FORMAT: "APS Line Reconfigured. SF BER changed from 1E-%d to 1E-%d workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "SF Ber changed by user. The old and new SF Ber values will be displayed in the eventlog. "
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-6-CNF_SDBER
SEVERITY: Notice
FORMAT: "APS Line Reconfigured. SD BER changed from 1E-%d to 1E-%d workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "SD Ber changed by user. The old and new SD Ber values will be displayed in the eventlog. "
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-6-CNF_WTR
SEVERITY: Notice
FORMAT: "APS Line Reconfigured. WTR changed from %d to %d workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Wtr changed by user. The old and new WTR values will be displayed in the eventlog. "
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-6-CNF_DIR
SEVERITY: Notice
FORMAT: "APS Line Reconfigured. Direction changed to %s workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "DIR changed by user. The event is logged only when there is change in the direction. New direction can be determined by event log."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-CNF_PROTO
SEVERITY: Information
FORMAT: "APS Line Reconfigured Protocol changed from %s to %s for workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS line pair mode, protocol changed"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-CNF_OPMODE
SEVERITY: Information
FORMAT: "Card configured for: %s "
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Card is configured either of AxsmA/AxsmB"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-7-APS_OPMODE_ERR
SEVERITY: Information
FORMAT: "ERROR card configured for %s software, PXM has returned NULL info for logical slot "
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "By default card is configured as AxsmA, PXM has sent NULL info for slot"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-6-CNF_REV
SEVERITY: Notice
FORMAT: "APS Line Reconfigured. Mode changed to %s workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "REV changed by user. The event is logged only when there is change in the mode. New value can be determined by the event log."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-3-SF_DECL
SEVERITY: Minor Alert
FORMAT: "APS SF Bit Error on Line Index = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Signal Fail condition detected."
RECOMMENDED ACTION: "Check the line cable on local end and remote end. Check the backcard status on local end and remote end. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsplog -sl <other slot in the pair if redundancy is configured> -mod APS
On each AXSM card, at both ends of the APS line
a) dspver
b) dspapsbkplane - for intercard APS setup only. Capture output
on Active and Standby cards.
c) dspapsln <the line mentioned in the eventlog>
d) dspalm -sonet <line mentioned in the eventlog>
e) dspbecnt <line mentioned in the eventlog>
Capture the output of following shell command on Active and Standby AXSM cards ApsDisplayEventTraceLineId <slot-id> <0-based baynum>
APS-3-SF_DECL_CLEAR
SEVERITY: Minor Alert
FORMAT: "APS SF Bit Error Cleared on Line Index = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Signal Fail alarm condition cleared. Logging the event for informational purpose."
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
On AXSM card
a) dspver b)dspapsln <the line mentioned in the eventlog> "
APS-3-SW_SERVICE
SEVERITY: Minor Alert
FORMAT: "User Requested APS Service Switch workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Line Service Switch requested by user is successful. Traffic may have been disturbed."
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "No information required. "
APS-4-PSBF_CLEARED
SEVERITY: Error
FORMAT: "APS Protection Switch Byte Failure Cleared workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Protection Switching Byte Failure has been Cleared."
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "No information required. "
APS-4-CHAN_MIS_CLEARE
SEVERITY: Error
FORMAT: "APS Channel Mismatch Failure Cleared workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Channel mismatch Failure Cleared. RxK1 and TxK1 channel-ids matched."
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "No information required. "
APS-2-FAR_END_FAIL
SEVERITY: Major Alert
FORMAT: "APS Far End Failure workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Far end Protection Line Failure detected. "
RECOMMENDED ACTION: "Check the protection line status on the remote node. "
REQUIRED INFO: "Capture the output of following CLIs on both nodes. On PXM45
a) dsplog -sl <slot that experianced the error> -mod APS
On AXSM card
a) dspver b)dspapsln <the line mentioned in the eventlog> "
APS-2-FAR_END_FAIL_CL
SEVERITY: Major Alert
FORMAT: "APS Far End Failure cleared workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Far end Prot Byte Fail Cleared. This may result into line switch."
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "No information required. "
APS-2-MODE_MISMATCH
SEVERITY: Major Alert
FORMAT: "APS Mode Mismatch workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS mode mismatch detected. RxK2 byte mode is different from the Provisioned mode. This may result into change in the APS line operating mode. "
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
On AXSM card
a) dspver b)dspapsln <the line mentioned in the eventlog> "
APS-6-MODE_MIS_CLEAR
SEVERITY: Notice
FORMAT: "APS Mode Mismatch Cleared workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS mode mismatch cleared. RxK2 byte mode is same as the Provisioned mode. This may result into change in the APS line operating mode."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-4-SW_CLEAR_FAIL
SEVERITY: Error
FORMAT: "Cannot do APS Switch Clear %s workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Line Clear command Failed. Check the reason displayed in the eventlog."
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of these CLIs
a) dspver
b) dspapsln <the line mentioned in the eventlog>
Capture the output of following shell command on Active card ApsDisplayEventTraceLineId <slot-id> <0-based baynum> <0-based linenum> "
APS-4-SW_LOCK_FAIL
SEVERITY: Error
FORMAT: "Cannot do APS Switch Lockout %s workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Line Lockout command failed. Check the reason displayed in the eventlog."
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of these CLIs
a) dspver
b) dspapsln <the line mentioned in the eventlog>
Capture the output of following shell command on Active card ApsDisplayEventTraceLineId <slot-id> <0-based baynum> <0-based linenum> "
APS-4-SW_FORCE_WTOP_F
SEVERITY: Error
FORMAT: "Cannot do APS Switch Forced Work->Prot %s workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Line Forced W->P Switch command failed. Check the reason displayed in the eventlog"
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "Capture the output of these CLIs
a) dspver
b) dspapsln <the line mentioned in the eventlog>
Capture the output of following shell command on Active card ApsDisplayEventTraceLineId <slot-id> <0-based baynum> <0-based linenum> "
APS-4-SW_FORCE_PTOW_F
SEVERITY: Error
FORMAT: "Cannot do APS Switch Forced Prot->Work %s workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Line Forced P->W Switch command failed. Check the reason displayed in the eventlog"
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "Capture the output of these CLIs
a) dspver
b) dspapsln <the line mentioned in the eventlog>
Capture the output of following shell command on Active card ApsDisplayEventTraceLineId <slot-id> <0-based baynum> <0-based linenum> "
APS-4-SW_MAN_WTOP_FAI
SEVERITY: Error
FORMAT: "Cannot do APS Manual Switch Work->Prot %s workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Line Manual W->P Switch command failed. Check the reason displayed in the eventlog."
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of these CLIs
a) dspver
b) dspapsln <the line mentioned in the eventlog>
Capture the output of following shell command on Active card ApsDisplayEventTraceLineId <slot-id> <0-based baynum> <0-based linenum> "
APS-4-SW_MAN_PTOW_FAI
SEVERITY: Error
FORMAT: "Cannot do APS Manual Switch Prot->Work %s workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Line Manual P->W Switch command failed. Check the reason displayed in the eventlog."
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of these CLIs
a) dspver
b) dspapsln <the line mentioned in the eventlog>
Capture the output of following shell command on Active card ApsDisplayEventTraceLineId <slot-id> <0-based baynum> <0-based linenum> "
APS-3-SD
SEVERITY: Minor Alert
FORMAT: "APS Signal Degrade on Line Index %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Line Signal Degrade alarm detected. "
RECOMMENDED ACTION: "Check the cable and backcard status."
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsplog -sl <other slot in the pair if redundancy is configured> -mod APS
On each AXSM card, at both ends of the APS line
a) dspver
b) dspapsbkplane - for intercard APS setup only. Capture output
on Active and Standby cards.
c) dspapsln <the line mentioned in the eventlog>
d) dspalm -sonet <line mentioned in the eventlog>
e) dspbecnt <line mentioned in the eventlog>
Capture the output of following shell command on Active and Standby AXSM cards ApsDisplayEventTraceLineId <slot-id> <0-based baynum>
APS-3-SD_CLEAR
SEVERITY: Minor Alert
FORMAT: "APS Signal Degrade Cleared on Line Index %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Line SD cleared. Logging the event for informational purpose."
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "No information required. "
APS-3-SW_SF
SEVERITY: Minor Alert
FORMAT: "APS Internal Switch due to APS Signal Fail High %s workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Switch due to Signal Fail. "
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
On AXSM card
a) dspver b)dspapsln <the line mentioned in the eventlog> "
APS-3-SW_SD
SEVERITY: Minor Alert
FORMAT: "APS Internal Switch due to APS Signal Degrade High %s workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Switch due to Signal Degrade. "
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
On AXSM card
a) dspver b)dspapsln <the line mentioned in the eventlog> "
APS-3-SW_REV
SEVERITY: Minor Alert
FORMAT: "APS Reverse Request switch %s workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Reverse Request Switch. "
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
On AXSM card
a) dspver b)dspapsln <the line mentioned in the eventlog> "
APS-3-SW_DONOT_REV
SEVERITY: Minor Alert
FORMAT: "APS Do Not Revert Request switch %s workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Do Not Revert Request Switch. "
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
On AXSM card
a) dspver b)dspapsln <the line mentioned in the eventlog> "
APS-3-SW_WTR
SEVERITY: Minor Alert
FORMAT: "APS Wait To Restore Expire switch %s workLN = %s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "APS Switch on Wait To Restore timer expiration. "
RECOMMENDED ACTION: "No action required. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
On AXSM card
a) dspver b)dspapsln <the line mentioned in the eventlog> "
APS-3-SW_UNKNOWN
SEVERITY: Minor Alert
FORMAT: "APS Unknown switch Reason %s workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Unknown switch Reason. In normal operation, such an error should never get reported."
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
APS-4-SW_SF_FAIL
SEVERITY: Error
FORMAT: "APS Internal Switch due to APS Signal Fail High FAILED %s workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Switch due to SF failed. "
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of these CLIs
a) dspver
b) dspapsln <the line mentioned in the eventlog>
Capture the output of following shell command on Active card ApsDisplayEventTraceLineId <slot-id> <0-based baynum> <0-based linenum> "
APS-4-SW_SD_FAIL
SEVERITY: Error
FORMAT: "APS Internal Switch due to APS Signal Degrade FAILED %s workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Switch due to SD failed. "
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of these CLIs
a) dspver
b) dspapsln <the line mentioned in the eventlog>
Capture the output of following shell command on Active card ApsDisplayEventTraceLineId <slot-id> <0-based baynum> <0-based linenum> "
APS-4-SW_REV_FAIL
SEVERITY: Error
FORMAT: "APS Reverse Request switch FAILED %s workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Reverse Request Switch Failed. "
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of these CLIs
a) dspver
b) dspapsln <the line mentioned in the eventlog>
Capture the output of following shell command on Active card ApsDisplayEventTraceLineId <slot-id> <0-based baynum> <0-based linenum> "
APS-3-SW_DONOT_REV_FA
SEVERITY: Minor Alert
FORMAT: "APS Do Not Revert Request switch Failed %s workLN = %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Do Not Revert Request Switch Failed. "
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of these CLIs
a) dspver
b) dspapsln <the line mentioned in the eventlog>
Capture the output of following shell command on Active card ApsDisplayEventTraceLineId <slot-id> <0-based baynum> <0-based linenum> "
APS-7-APS_CHMM_FAILUR
SEVERITY: Information
FORMAT: "APS Error Work Line index %s function 0X%X line %d Channel Mismatch Failure declared TXK1K2RxK1K2 0x%x"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Channel Mismatch Failure declared. RxK1 and TxK1 channel-id do not match."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
APS-4-APS_PHY_ERR
SEVERITY: Error
FORMAT: "APS Error Line index %s function 0X%X line %d exit due to major %d minor %d error"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "APS Task Error in Phy api module. Unable to read/write register."
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "No information required. "
APS-4-APS_PHY_BAD_PAR
SEVERITY: Error
FORMAT: "PHY Error function 0X%X, line %d passed invalid param to DRV_set LineObj 0x%x, chanDesc 0x%x, param_id %d"
FLAG: Stack Trace
THROTTLING: No Throttling
EXPLANATION: "APS Task Error in Phy api module. DRV returned error due to bad input parameter."
RECOMMENDED ACTION: "Copy the error message exactly as it appears in the system log. call your Cisco technical support representative and provide the representative with the gathered information. "
REQUIRED INFO: "Capture the output of these CLIs On PXM45
a) dsplog -sl <slot that experianced the error>
b) dsperr -sl <slot that experianced the error> "
DDTS "unknown"
SSI-4-ARCH_ERROR
SEVERITY: Error
FORMAT: "Archive Error %s "
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "The archive file doesn't exist on the service module."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: No Required Info
DDTS "pxm-connmgm"
SSI-4-ARCH_ERROR
SEVERITY: Error
FORMAT: "Archive Error %s "
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "The archive file for the corresponding service module could be either corrupted or failed to create."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "Collect dsplog, dsperr, dspdbinfo <slot> 3 information"
DDTS "shm"
ENVM-4-ADC_CONV_ERROR
SEVERITY: Error
FORMAT: "ADC Conversion Failed"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "This log event indicates an error condition in the A/D Converter. Specifically, a sensor could not be monitored. We allow a total of three errors before logging this event."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: " a) From shellconn on PXM pxm> lkup \"adcError\" Dump given memory location using \"d\"
b) dspenvalms on PXM
c) Fromm shellconn on PXM
pxm> showall(1) Capture debug output pxm> showall(0) "
ENVM-4-ADC_ERROR
SEVERITY: Error
FORMAT: "ADC Error"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "This log event indicates an error condition in the A/D Converter. Specifically, a sensor could not be monitored. We allow a total of three errors before logging this event."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: " a) From shellconn on PXM pxm> lkup \"adcError\" Dump given memory location using \"d\"
b) dspenvalms on PXM
c) Fromm shellconn on PXM
pxm> showall(1) Capture debug output pxm> showall(0) "
ENVM-2-ENV_ALARM_SET
SEVERITY: Major Alert
FORMAT: "Environmental Alarm Set %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "This log event indicates an environmental monitoring alarm has occurred."
RECOMMENDED ACTION: No action required
REQUIRED INFO: " a) dsplog -mod ENVM on PXM
b) dspndalms on PXM
c) dspenvalms on PXM "
ENVM-3-ENV_ALARM_CLR
SEVERITY: Minor Alert
FORMAT: "Environmental Alarm Clr %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "This log event indicates an environmental monitoring alarm has cleared."
RECOMMENDED ACTION: No action required
REQUIRED INFO: " a) dsplog -mod ENVM on PXM
b) dspndalms on PXM
c) dspenvalms on PXM "
ENVM-4-ENV_TRAP_GEN
SEVERITY: Error
FORMAT: "Cannot Send Trap %s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "This log event indicates an error in sending an enviromental monitoring trap to the network management system(s)."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: " a) dsplog -mod ENVM on PXM
b) dspndalms on PXM
c) dspenvalms on PXM "
ENVM-4-ENV_ERROR
SEVERITY: Error
FORMAT: "%s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "This log event indicates a failure in an API called by the environmental monitoring code."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: " a) dsplog -mod ENVM on PXM
b) dspndalms on PXM
c) dspenvalms on PXM
d) from shellconn on PXM
pxm> showNode Capture output of debug display. "
DDTS "drivers/ccma"
ATLA-4-AT_INIT_ERR
SEVERITY: Error
FORMAT: "ATLAS Error Atlas No %d function 0X%X line %d exit due to %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: " Error Caused during Initialisation of Atlas"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
ATLA-4-AT_INTRPT_ERR
SEVERITY: Error
FORMAT: "ATLAS Error Atlas No %d function 0X%X line %d exit due to %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: " Specifies the Interrupts caused."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
ATLA-4-AT_GEN_ERR
SEVERITY: Error
FORMAT: "ATLAS Error Atlas No %d function 0X%X line %d exit due to %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: " General Error. "
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
ATLA-4-AT_PARAM_ERR
SEVERITY: Error
FORMAT: "ATLAS Error Atlas No %d function 0X%X line %d exit due to %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: " Incorrect parameter was passed to ATLAS driver."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
ATLA-4-AT_ACCESS_ERR
SEVERITY: Error
FORMAT: "ATLAS Error Atlas No %d function 0X%X line %d exit due to %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: " Access to Atlas failed. ATLAS is busy. The major and minor params have been specified."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
ATLA-4-AT_CONACC_ERR
SEVERITY: Error
FORMAT: "ATLAS Error Atlas No %d function 0X%X line %d exit due to %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: " Access Connection information failed."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
DDTS "atmsig"
ATMC-5-INTERNAL_CRITIC
SEVERITY: Warning
FORMAT: "%s"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "It describes the internal error for Connection Management module on PNNI controller."
RECOMMENDED ACTION: "Gather the following information: connection statuschanged? Interface status changed? And then contact your TAC representative."
REQUIRED INFO: "Collect node info on PNNI controller using command of (dsplog), (dspcds), (dspver), (dsplog -mod ATMC), (dspconinfo)"
ATMC-5-P2MP_ERR
SEVERITY: Warning
FORMAT: "%s"
FLAG: Stack Trace
THROTTLING: One Second
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
ATMC-5-P2MP_WARN
SEVERITY: Warning
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Second
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
ATMC-7-P2MP_INFO
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Second
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
ATMS-4-ATMSIG_PRTY_INS
SEVERITY: Error
FORMAT: "ATMSIG(%s %d,%d - %04d/%02d) avl prty ins failedsvc 0x%x party 0x%x"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Failed to store into SVC party database."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: On PXM cli the output of the following commands dspver, dspcds, dspdate, dsppnports, dspsigstats, dsppncons, dsppnctlvc, dsplog, dspmempart can be sent to the Cisco Customer support.
ATMS-4-ATMSIG_PRTY_DEL
SEVERITY: Error
FORMAT: "ATMSIG(%s %d,%d - %04d/%02d) avl prty del failedsvc 0x%x party 0x%x"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Failed to delete from SVC party database."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: On PXM cli the output of the following commands dspver, dspcds, dspdate, dsppnports, dspsigstats, dsppncons, dsppnctlvc, dsplog, dspmempart can be sent to the Cisco Customer support.
ATMS-4-ATMSIG_SVC_INSE
SEVERITY: Error
FORMAT: "ATMSIG(%s %d,%d - %04d/%02d) SVC wavl ins failedsvc 0x%x"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Failed to store into SVC connection database."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: On PXM cli the output of the following commands dspver, dspcds, dspdate, dsppnports, dspsigstats, dsppncons, dsppnctlvc, dsplog, dspmempart can be sent to the Cisco Customer support.
ATMS-4-ATMSIG_SVC_DELE
SEVERITY: Error
FORMAT: "ATMSIG(%s %d,%d - %04d/%02d) SVC wavl del failedsvc 0x%x"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Failed to delete from SVC connection database."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: On PXM cli the output of the following commands dspver, dspcds, dspdate, dsppnports, dspsigstats, dsppncons, dsppnctlvc, dsplog, dspmempart can be sent to the Cisco Customer support.
ATMS-4-NOSVC
SEVERITY: Error
FORMAT: "no SVC, %s"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "No SVC datastructure found for connection."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: On PXM cli the output of the following commands dspver, dspcds, dspdate, dsppnports, dspsigstats, dsppncons, dsppnctlvc, dsplog, dspmempart can be sent to the Cisco Customer support.
ATMS-4-NOCALLREF
SEVERITY: Error
FORMAT: "Cannot find a Callref value to allocate %s"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "The call reference structures are inconsistant."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: On PXM cli the output of the following commands dspver, dspcds, dspdate, dsppnports, dspsigstats, dsppncons, dsppnctlvc, dsplog, dspmempart can be sent to the Cisco Customer support.
ATMS-6-FAILHALFLEGREM
SEVERITY: Notice
FORMAT: "halfLeg removal failed, %s"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Failed to remove endpoint connection resources."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: On PXM cli the output of the following commands dspver, dspcds, dspdate, dsppnports, dspsigstats, dsppncons, dsppnctlvc, dsplog, dspmempart can be sent to the Cisco Customer support.
ATMS-4-FAIL2NDHALFLEG
SEVERITY: Error
FORMAT: "halfLeg removal failed, %s"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Failed to remove endpoint connection resources."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: On PXM cli the output of the following commands dspver, dspcds, dspdate, dsppnports, dspsigstats, dsppncons, dsppnctlvc, dsplog, dspmempart can be sent to the Cisco Customer support.
ATMS-4-FAILXCONN
SEVERITY: Error
FORMAT: "Xconn failed, %s"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Synchronous faliure in connection commit."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: On PXM cli the output of the following commands dspver, dspcds, dspdate, dsppnports, dspsigstats, dsppncons, dsppnctlvc, dsplog, dspmempart can be sent to the Cisco Customer support.
SCHE-4-UNEXPECTEDMESSA
SEVERITY: Error
FORMAT: "Unknown message %x received (msgb %x, ssi_rcvid %x)."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Task cannot recognize the CLI message."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: On PXM cli the output of the following commands dspver, dspcds, dspdate, dsppnports, dspsigstats, dsppncons, dsppnctlvc, dsplog, dspmempart can be sent to the Cisco Customer support.
SCHE-4-UNEXPECTEDEVENT
SEVERITY: Error
FORMAT: "Process received unknown event (maj %x, min %x)."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Unexpected event received in current state"
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: On PXM cli the output of the following commands dspver, dspcds, dspdate, dsppnports, dspsigstats, dsppncons, dsppnctlvc, dsplog, dspmempart can be sent to the Cisco Customer support.
SCHE-4-UNEXPECTEDTIMER
SEVERITY: Error
FORMAT: "Unknown timer expiration, timer = %x, type %d."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Timeout received with invalid context."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: On PXM cli the output of the following commands dspver, dspcds, dspdate, dsppnports, dspsigstats, dsppncons, dsppnctlvc, dsplog, dspmempart can be sent to the Cisco Customer support.
DDTS "unknown"
ADDR-5-ADDR_ERROR
SEVERITY: Warning
FORMAT: "%s"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
ADDR-7-ADDR_INFORMATIV
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
DDTS "ifm"
IFM-4-ERROR
SEVERITY: Error
FORMAT: "IFM Internal Err%s"
FLAG: Stack Trace
THROTTLING: No Throttling
EXPLANATION: "It describes the internal error for IFM module on PNNI controller."
RECOMMENDED ACTION: "Target which interface has problem and check(1)if the interface status has changed;(2)if there are connections on the interface and if connections status has changed or not.Gather all the interface related information and contact your TAC representative."
REQUIRED INFO: "Collect node info on PNNI controller using dspver,dspcds,dsppnports; collect IFM log using (dsplog -mod IFM);if specific port is known,collect port info using (dsppnport portID)"
IFM-5-CRITICAL
SEVERITY: Warning
FORMAT: "%s"
FLAG: Stack Trace
THROTTLING: No Throttling
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
IFM-5-WARNING
SEVERITY: Warning
FORMAT: "%s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
IFM-7-INFO
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
IFM-6-NOTICE
SEVERITY: Notice
FORMAT: "%s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
DDTS "atmsig"
VCM-6-LEG_CREATE
SEVERITY: Notice
FORMAT: "PnNet/VCM/%s: %s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Information about control vc leg creation status"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
ATMC-5-INTERNAL_WARNIN
SEVERITY: Warning
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Second
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
ATMC-5-SETCAC_WARN
SEVERITY: Warning
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Second
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
ATMC-5-BITMAP_ERR
SEVERITY: Warning
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Second
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
ATMC-5-BITMAP_WARN
SEVERITY: Warning
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Second
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
ATMC-7-BITMAP_INFO
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Second
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
DDTS "atmsig"
TRAF-5-ADDFAIL
SEVERITY: Warning
FORMAT: "%s Fail to add %s trf parm to database"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Fail to add traffic parameter to database"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-5-DELFAIL
SEVERITY: Warning
FORMAT: "%s Fail to del %s trf parm from database"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Fail to delete traffic parameter from database"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-5-NOABRPARM
SEVERITY: Warning
FORMAT: "%s Missing %s abr trf parm for abr conn"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Missing abr traffic parameters for abr conn"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-5-DBCREATEFAIL
SEVERITY: Warning
FORMAT: "%s Not able to create DB"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Not able to create DB"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-5-NULLPTR
SEVERITY: Warning
FORMAT: "%s %s is null at position %d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Given pointer is null"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-5-NULLELEPTR
SEVERITY: Warning
FORMAT: "%s %s is null with index %d at position %d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Given element pointer is null"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-5-BADELE
SEVERITY: Warning
FORMAT: "%s Bad %s traffic element - index=%d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Bad element in traffic database"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-5-BADELECHKSUM
SEVERITY: Warning
FORMAT: "%s Bad %s trf ele in same chksum list - index=%d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Bad traffic element in same checksum list"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-5-BROKENLIST
SEVERITY: Warning
FORMAT: "%s Broken same chksum list for %s trf - index=%d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Broken link list"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-5-NOTINFREELIST
SEVERITY: Warning
FORMAT: "%s %s - index %d not in free list"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Element not in free list"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-5-NOTINUSE
SEVERITY: Warning
FORMAT: "%s %s - index %d not in use"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Element not in use"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-5-NOTALLOC
SEVERITY: Warning
FORMAT: "%s %s - index %d not allocated"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Element not allocated"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-5-CANNOTFREE
SEVERITY: Warning
FORMAT: "%s Ref count not equal to 1 for %s trf index=%d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Cannot free element because someone still refering to it"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-5-MISMATCHCKSM
SEVERITY: Warning
FORMAT: "%s %s trf chksum mismatch - index=%d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Traffic chksum mismatch"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-5-DECREFCNTFAIL
SEVERITY: Warning
FORMAT: "%s Decrease reference count fail - index=%d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Decrease reference count fail"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-5-DECREMENTERR
SEVERITY: Warning
FORMAT: "%s %s trf decrement error - total outstanding already zero "
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Decrement error total outstanding already zero"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-5-INVTRFIDX
SEVERITY: Warning
FORMAT: "%s %s traffic index is invalid - index=%d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Traffic index is invalid"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-5-ALLOCFAIL
SEVERITY: Warning
FORMAT: "%s Fail to allocate %s element"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Fail to allocate element"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-5-INSERTFAIL
SEVERITY: Warning
FORMAT: "%s Fail to insert %s element; index%d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Fail to insert element"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-5-NEWBLKALLOCFAIL
SEVERITY: Warning
FORMAT: "%s Fail to allocate new %s block - CONGESTION ON"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Fail to allocate new block - CONGESTION ON"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-5-BUFALLOCFAIL
SEVERITY: Warning
FORMAT: "%s Fail to allocate %s buffer"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Fail to allocate buffer"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-7-NOTENGBUF
SEVERITY: Information
FORMAT: "%s Running out of %s traffic buffers - CONGESTION ON"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Running out of traffic buffers - CONGESTION ON"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
TRAF-7-CONGOFF
SEVERITY: Information
FORMAT: "%s %s CONGESTION OFF"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Turn off congestion"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
DDTS "unknown"
VCM-5-WARNING
SEVERITY: Warning
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
VCM-7-INFO
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
VCM-6-NOTICE
SEVERITY: Notice
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
VCM-7-CONN_INSTALLSVC
SEVERITY: Information
FORMAT: "Func %s , Err Cause%s If %lx vpi %d vci %d\n"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CM-7-CONN_ALLOCVXL_E
SEVERITY: Information
FORMAT: "Func %s , Err Cause%s If %lx vpi %d vci %d\n"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
DDTS "unknown"
VCM-7-VCM_INSTALL_XCO
SEVERITY: Information
FORMAT: "Func %s API%s, Err Cause%s If %lx vpi %d vci %d\n"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
VCM-7-VCM_BIG_DELETE_
SEVERITY: Information
FORMAT: "Func %s Cause%s If %lx vpi %d vci %d\n"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
VCM-7-VCM_RECOMMIT_TI
SEVERITY: Information
FORMAT: "Func %s Cause %s If %lx vpi %d vci %d\n"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
VCM-7-VCM_FRCE_RESYNC
SEVERITY: Information
FORMAT: "Func %s Cause %s If %lx vpi %d vci %d\n"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
VCM-6-NOTICE
SEVERITY: Notice
FORMAT: "%s"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Event explanation comes at later point"
RECOMMENDED ACTION: "Recommended action for this event comes at a later point \n"
REQUIRED INFO: No Required Info
DDTS "unknown"
CSR-7-INFO
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CSR-6-NOTICE
SEVERITY: Notice
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CSR-5-WARNING
SEVERITY: Warning
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CSR-4-ERROR
SEVERITY: Error
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "internal software error"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: "capture log using dsplog -mod CSR"
CSR-7-CONGEST
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CSR-7-NULL_PTR
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CSR-7-MALLOC_FAIL
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CSR-7-TIMEOUT
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CSR-7-ABORT_FAIL
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CSR-7-INTF
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CSR-7-PEP
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CSR-7-DISK_FAIL
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CSR-7-START_END
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CSR-7-BUFFER_UPDT
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CSR-7-REDO_UPDT
SEVERITY: Information
FORMAT: "%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
DDTS "spvc"
SPVC-4-SWERROR
SEVERITY: Error
FORMAT: "SOFTWARE ERROR <%d> %d %d %d %d"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "The meaning for variables in the FORMAT string is given below First parameter can be one of following value :
3001 : Connection Management data structure scalling error \
3002 : Error n upping and downing connection \
3003 : Connetion backward bandwidth error \
3004 : Connetion forward bandwidth error \
3005 : NSAP Index error \
3006 : Resync database error \
Second parameter : Logical id of interface \
Third parameter : vpi \
Fourth parameter: vci \
Fifth Parameter : Not used "
RECOMMENDED ACTION: Issue these comamnds on the shell prompt
a) dspver
b) dsplogs
c) dsperrs
d) dsppnports
e) dspcons
f) dspcon
REQUIRED INFO: Collect output of these CLIs
a) dspver b) dsplogs c) dspvers d) dsppnports e) dspcons
f) dspcon for connection in problem
DDTS "axsm-apps/shm"
AXDG-4-ERR
SEVERITY: Error
FORMAT: "AXSM diagnostic error Error 0x%x, %s, %d, 0x%x, 0x%x\n"
FLAG: No Flag
THROTTLING: One Second
EXPLANATION: "Error condition detected. It may cause AXSM diag not to operate properly and require AXSM reset to work properly again. There is a log that asks user to clrdiagerr <slot> to restart online diag. This happens during PXM state change such as switchcc. In this case, there is no need to reset AXSM. Just execute clrdiag as advised. "
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM45
1. dspcds
2. dspcd <slot that experienced the error>
3. dsplog -sl <slot that experienced the error>
4. dsplog -sl <other slot in the pair if redundancy is configured>
5. dsperr for slots specified above.
6. dspdiagcnf
7. dspdiagstatus
8. dspdiagerr online
9. dspdiagerr offline
10. dspdiagstat <slot that experienced the error>
On AXSM
1. dspver
2. dsplns
3. dspports "
AXDG-4-LOGTRC
SEVERITY: Error
FORMAT: "%s error in AXSM diagnostic 0x%x, %s, %d, %d\n"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Error condition detected. It may cause AXSM diag not to operate properly and require AXSM reset to work properly again. There is a log that asks user to clrdiagerr <slot> to restart online diag. This happens during PXM state change such as switchcc. In this case, there is no need to reset AXSM. Just execute clrdiag as advised. "
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM45
1. dspcds
2. dspcd <slot that experienced the error>
3. dsplog -sl <slot that experienced the error>
4. dsplog -sl <other slot in the pair if redundancy is configured>
5. dsperr for slots specified above.
6. dspdiagcnf
7. dspdiagstatus
8. dspdiagerr online
9. dspdiagerr offline
10. dspdiagstat <slot that experienced the error>
On AXSM
1. dspver
2. dsplns
3. dspports "
AXDG-7-OFFLN
SEVERITY: Information
FORMAT: "%s, %d, %d, %d\n"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Show offline diagnostic progress"
RECOMMENDED ACTION: "Just information for offline diagnostic progress, no action is required"
REQUIRED INFO: No Required Info
AXDG-7-ONLN_STATUS
SEVERITY: Information
FORMAT: "Online diag status transition detected %s, %s\n"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Online diag test run success-to-fail or fail-to-success transition is detected. Test run result is integrated (usually takes 5 consecutive test run failures) before online diag failure is reported to PXM. Therefore these events can be logged without PXM declaring AXSM online diag failure, when test run failure is intermittent. Intermittent failure may be caused by temporarily congestion in which case failure should go away after congestion is gone."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM45
1. dspcds
2. dspcd <slot that experienced the error>
3. dsplog -sl <slot that experienced the error>
4. dspver
5. dspdiagcnf
6. dspdiagerr online
On AXSM
1. dspcd
2. dsdver"
DDTS "boot/shm"
BOOT-5-SERIALHUNGHCR
SEVERITY: Warning
FORMAT: "Serial port is hung (HCR wrong) (hcr=%08lx)."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "The serial port is hung (HCR is set wrong), resetting the serial device."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: No Required Info
BOOT-5-SERIALHUNGREAD
SEVERITY: Warning
FORMAT: "Serial port is hung (read int.) (icr=%08lx)."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "The serial port is hung (read interrupt disabled), resetting the serial device."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: No Required Info
BOOT-5-SERIALHUNGWRITE
SEVERITY: Warning
FORMAT: "Serial port is hung (write int.) (icr=%08lx, count=%d)."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "The serial port is hung (write interrupt disabled), resetting the serial device."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: No Required Info
BOOT-5-ETHERCHIPHUNG
SEVERITY: Warning
FORMAT: "Ethernet chip is hung (%s 0x%x). Restarting chip."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "The ethernet chip is hung, resetting the ethernet device."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: No Required Info
BOOT-2-LANLOSTCARR
SEVERITY: Major Alert
FORMAT: "Ethernet Loss Of Carrier Detected."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "The ethernet driver has detected a loss of carrier."
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
BOOT-2-LANLOSTCARR_CLR
SEVERITY: Major Alert
FORMAT: "Ethernet Loss Of Carrier Cleared."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "The ethernet driver has detected that carrier has returned."
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
BOOT-4-HMASTER_NO_HREA
SEVERITY: Error
FORMAT: "BOOT ERR HMASTER is YES, HREADY is NO is detected in %s. FWREADY is not asserted."
FLAG: Write to Bram
THROTTLING: One Tick
EXPLANATION: "HMASTER is YES, HREADY is NO. PIO FWREADY bit is not asserted."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: No Required Info
BOOT-5-UNEXPECTED_INTE
SEVERITY: Warning
FORMAT: "Unexpected Interrupt, vec=%d CauseR=0x%x SR=0x%x ticks=%d"
FLAG: Write to Bram
THROTTLING: No Throttling
EXPLANATION: "These interrupts will only be raised when hardware or device is misconfigured or run into some erroneous conditions. If the same interrupt happens less frequently than the predefined threshold, this message will be logged, otherwise, the board will be reset."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: No Required Info
BOOT-4-UNEXPECTED_INTE
SEVERITY: Error
FORMAT: "Unexpected interrupt vec=%d CauseR=0x%x SR=0x%x ticks=%d passed threshold=%d in %d ticks"
FLAG: Write to Bram
THROTTLING: No Throttling
EXPLANATION: "These interrupts will only be raised when hardware or device is misconfigured or run into some erroneous conditions. If the same interrupt happens more frequently than the predefined threshold, this message will be logged and the board will be reset."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "If the card was reset automatically, core may have been dumped on the hard disk of the Active controller card. If the core was dumped, collect the core. If the card was not reset, call TAC to reset the card in such a way that core would be dumped. Collect the event and error logs.
BOOT-7-BURNBOOT_REQ_DE
SEVERITY: Information
FORMAT: "Burnboot request detected."
FLAG: Write to Bram
THROTTLING: One Tick
EXPLANATION: "Burnboot signature file was found by backupboot."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
BOOT-4-BURNBOOT_SIGFIL
SEVERITY: Error
FORMAT: "Signature file was found to be present but could not be read. Burnboot aborted.\n"
FLAG: Write to Bram
THROTTLING: One Tick
EXPLANATION: "Signature file for burnboot was found to be present but could not be read. Burnboot aborted."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "The burnboot version file was found to be present but could not be read during backupboot."
BOOT-4-BURNBOOT_SIGFIL
SEVERITY: Error
FORMAT: "Signature file content were not in expected format. The file has been renamed to bootver.sav for debugging. Burnboot aborted.\n"
FLAG: Write to Bram
THROTTLING: One Tick
EXPLANATION: "Signature file for burnboot was found to be present but it's contents were not in the expected format. The file is saved as C:/bootver.sav for debugging purposes and card has continued to boot with current boot version. Burnboot aborted."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "After the card boots up, get output of <dsplog -mod SHM_> from the active PXM card. Then ftp to the PXM card in question, and get the file C:/bootver.sav"
BOOT-4-BURNBOOT_SW_ID_
SEVERITY: Error
FORMAT: "Could not extract CTC_SW_ID from the signature file. Burnboot aborted.\n"
FLAG: Write to Bram
THROTTLING: One Tick
EXPLANATION: "Signature file contains the filename to be used for burning boot. Could not extract SW ID from the filename for matching with SW ID in BRAM."
RECOMMENDED ACTION: "Use the old method of boot revision upgrade, i.e., using 'sysFlashBootBurn' in backup boot"
REQUIRED INFO: "The burnboot signature file C:/bootver was read but it's contents could not be parsed well."
BOOT-4-BURNBOOT_VER_IN
SEVERITY: Error
FORMAT: "BRAM flag for burnboot could not be read. Burnboot aborted.\n"
FLAG: Write Bram
THROTTLING: One Tick
EXPLANATION: "Burnboot signature file was found and read, but the corresponding BRAM flag could not be read. Burnboot aborted."
RECOMMENDED ACTION: "Use the old method of boot revision upgrade, i.e., using 'sysFlashBootBurn' in backup boot"
REQUIRED INFO: "On the PXM card in question, go to shellcon and collect output of shell command 'logConsoleShow'"
BOOT-4-BURNBOOT_KEY_IN
SEVERITY: Error
FORMAT: "BRAM key for burnboot could not be read. Burnboot aborted.\n"
FLAG: Write to Bram
THROTTLING: One Tick
EXPLANATION: "Burnboot signature file and the corresponding BRAM flag were read, but the 'key' in BRAM could not be read. Burnboot aborted."
RECOMMENDED ACTION: "Use the old method of boot revision upgrade, i.e., using 'sysFlashBootBurn' in backup boot"
REQUIRED INFO: "On the PXM card, go to shellcon and collect output of shell command 'logConsoleShow'"
BOOT-7-BURNBOOT_SIGFIL
SEVERITY: Information
FORMAT: "Signature file contains version [%d][%d][%d][%d][%d]; Key=[%d].\n"
FLAG: Write to Bram
THROTTLING: One Tick
EXPLANATION: "Displays contents of the burnboot signature file."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: "On the PXM card, go to shellcon and collect output of shell command 'logConsoleShow'"
BOOT-7-BURNBOOT_BRAM_C
SEVERITY: Information
FORMAT: "BRAM contains version [%d][%d][%d][%d][%d]; Key=[%d].\n"
FLAG: Write to Bram
THROTTLING: One Tick
EXPLANATION: "Displays contents of the BRAM flags."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
BOOT-7-BURNBOOT_VERSIO
SEVERITY: Information
FORMAT: "Burnboot Version in BRAM and Sig file were not same. Burnboot aborted.\n"
FLAG: Write to Bram
THROTTLING: One Tick
EXPLANATION: "Burnboot Version in BRAM and Sig file did not match. Burnboot aborted. This would most usually happen if a front card and a back card from different nodes were removed with dangling signature file and BRAM flag for boot upgrade and were put in a new node."
RECOMMENDED ACTION: "Use the old method of boot revision upgrade, i.e., using 'sysFlashBootBurn' in backup boot"
REQUIRED INFO: No Required Info
BOOT-7-BURNBOOT_KEY_MA
SEVERITY: Information
FORMAT: "Burnboot key in BRAM and Sig file were not same. Burnboot aborted.\n"
FLAG: Write to Bram
THROTTLING: One Tick
EXPLANATION: "Burnboot key in BRAM and Sig file did not match. Burnboot aborted. This would most usually happen if a front card and a back card from different nodes were removed with dangling signature file and BRAM flag for boot upgrade and were put in a new node."
RECOMMENDED ACTION: "Use the old method of boot revision upgrade, i.e., using 'sysFlashBootBurn' in backup boot"
REQUIRED INFO: No Required Info
BOOT-4-BURNBOOT_FAILED
SEVERITY: Error
FORMAT: "Burnboot could not succeed. Aborted. Continuing to boot."
FLAG: Write to Bram
THROTTLING: One Tick
EXPLANATION: "Burnboot failed because the file was not found or it's checksum/header was not found to be okay."
RECOMMENDED ACTION: "Check for the presence of the file on the card in question, try to ftp it to the card again to make sure it is transferred successfully and retry. If it fails again, use the old method of boot revision upgrade, i.e., using 'sysFlashBootBurn' in backup boot"
REQUIRED INFO: "On the PXM card, go to shellcon and collect output of shell command 'logConsoleShow'"
BOOT-2-BURNBOOT_FAILED
SEVERITY: Major Alert
FORMAT: "Burnboot could not succeed. Aborted. Card is left in removed state for debugging. DO NOT RESET."
FLAG: Write to Bram
THROTTLING: One Tick
EXPLANATION: "Burnboot was started but during/after writing it, errors were detected and the process aborted midway. Rebooting the card at this point will be fatal and can render the card useless. DO NOT RESET THE CARD. Console port should be attached to the card for debugging."
RECOMMENDED ACTION: "DO NOT RESET THE CARD, it may be rendered useless. Console port should be attached to the card for debugging. Contact TAC for assistance."
REQUIRED INFO: No Required Info
BOOT-7-BURNBOOT_REQ_HA
SEVERITY: Information
FORMAT: "Burnboot request was successfully handled."
FLAG: Write to Bram
THROTTLING: One Tick
EXPLANATION: "Burnboot request was handled well. Cleanup was done and card reset."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
BOOT-4-W_RODATA
SEVERITY: Error
FORMAT: "Write to rodata badAddr=0x%x"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "A task attempted to write into read-only data section. This is often the result of a bug where a task writes to a constant string. It can also happens when writing to a stray pointer. Even though writing to rodata is a bad practise, the operation is allowed (but logged so bug can be fixed). Event is only logged once (further write attempts into rodata are silently allowed). As a result, there can be a memory corruption (most of the time, changing a string is harmless so there might be no consequence)"
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "Collect logs (dsplog) around W_RODATA event. Logs should contain a SSI EXCEPTION event corresponding to the read-only data corruption (same bad address in both events). Collect also errors (dsperr), at least error corresponding to SSI exception and containing stack trace."
DDTS "atmsig"
CA-4-CA_IPC_ERROR
SEVERITY: Error
FORMAT: "%s\n"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Call audit generic IPC error."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "Collect all the logs from dsplog command and outputs of dsppnports, dspconinfo "
CA-4-CA_TIMER_START_
SEVERITY: Error
FORMAT: "%s\n"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "SSI sync timer api returned error."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "Collect all the logs from dsplog command and outputs of dsppnports, dspconinfo"
CA-4-CA_GENERIC_ERRO
SEVERITY: Error
FORMAT: "CA/%s\n"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "call audit task generic error."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "Collect all the logs from dsplog command and outputs of dsppnports, dspconinfo"
CA-6-CA_GENERIC_NOTI
SEVERITY: Notice
FORMAT: "CA/%s\n"
FLAG: No Flag
THROTTLING: No Throttling
EXPLANATION: "Generic notice for call audit task."
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
DDTS "alarms"
CAM-5-INVALIDINPUT
SEVERITY: Warning
FORMAT: "One of the inputs to the function %s() was invalid."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "API Software Error. The parameter value for one of the parameters passed in as an argument to the named function was invalid."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CAM-5-PARMOUTOFTRANGE
SEVERITY: Warning
FORMAT: "Parm %s is out of range. The range is between %d and %d"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "API Software Error. The parameter value for the named parameter is out of range."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CAM-5-PARMINVALID
SEVERITY: Warning
FORMAT: "Parm %s value '0x%x' is invalid to %s."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "API Software Error. The parameter value for the named parameter passed in as an argument to the named function was invalid."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CAM-5-PARMINVLENGTH
SEVERITY: Warning
FORMAT: "Parm %s invalid length of %d to %s. Max=%d Value='%s'"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "API Software Error. The named paramater passed in as an argument to the named function either had a length of zero or exceeded the maximum value specified."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CAM-5-FUNCFAIL_STKDUM
SEVERITY: Warning
FORMAT: "%s() SNMP subsystem call to %s() failed. rc=%d."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "The specified function call failed. It failed with the specified return code. A stack trace was generated."
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
CAM-5-QUEUEFULL
SEVERITY: Warning
FORMAT: "Could not send Alarm Summary %d from slotnum %d."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "The CAM Client Queue has reached the high water mark"
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
DDTS "ccma"
DAL-4-DALERR
SEVERITY: Error
FORMAT: "DAL Error %s() line %d %X,%X"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
DAL-4-DALERR_STR
SEVERITY: Error
FORMAT: "DAL Error %s() line %d %X,%s"
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: No Explanation
RECOMMENDED ACTION: No Recommended Action
REQUIRED INFO: No Required Info
DDTS "snmp-ma"
CB_S-4-INVALIDINPUT
SEVERITY: Error
FORMAT: "One of the inputs to the function %s() was invalid."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "API Software Error. The parameter value for one of the parameters passed in as an argument to the named function was invalid."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev"
CB_S-4-PARMINVALID
SEVERITY: Error
FORMAT: "Parm %s value '0x%x' is invalid to %s."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "API Software Error. The parameter value for the named parameter passed in as an argument to the named function was invalid."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev"
CB_S-4-PARMINVLENGTH
SEVERITY: Error
FORMAT: "Parm %s invalid length of %d to %s. Max=%d Value='%s'"
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "API Software Error. The named paramater passed in as an argument to the named function either had a length of zero or exceeded the maximum value specified."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev"
CB_S-4-FUNCFAILSTK
SEVERITY: Error
FORMAT: "%s() SNMP subsystem call to %s() failed. rc=%d."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "The specified function call failed. It failed with the specified return code. A stack trace was generated."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev"
CB_S-4-FUNCFAIL
SEVERITY: Error
FORMAT: "%s() SNMP subsystem call to %s() failed. rc=%d."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "The specified function call failed. It failed with the specified return code."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev"
CB_S-4-PARMOUTOFRANGE
SEVERITY: Error
FORMAT: "%s() Parm %s '%d' is out of range %d-%d."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "API Software Error. The parameter value for the named parameter passed in as an argument to the named function is out of the specified range of values."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev"
CB_S-4-MALLOCFAILED
SEVERITY: Error
FORMAT: "%s() Call to ssiMalloc() failed."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "A call to allocate more memory has failed."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev
5. memshow"
CB_S-4-OPENTRANSFAIL
SEVERITY: Error
FORMAT: "OpenTransport() failed."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "An attempt to open the IP layer transport failed."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev
5. memshow"
CB_S-4-BINDTRANSFAIL
SEVERITY: Error
FORMAT: "BindTransport() failed."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "An attempt to bind to the IP layer transport failed."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev
5. memshow"
CB_S-4-RCVFRTRNSFAIL
SEVERITY: Error
FORMAT: "ReceiveFromTransport() failed."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "An attempt to receive a message from the IP layer failed."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev
5. memshow"
CB_S-4-MSGSENDFAIL
SEVERITY: Error
FORMAT: "%s() cntpMsgSend(Queue %s, ptr 0x%x len=%d) failed."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Attempt to send a control point message failed."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev
5. memshow"
CB_S-4-MSGRECVFAIL
SEVERITY: Error
FORMAT: "%s() cntpMsgRecv(Queue %s) failed."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Attempt to receive a control point message buffer failed."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev
5. memshow"
CB_S-4-BADSRMSLOT
SEVERITY: Error
FORMAT: "%s() Invalid SRM slot %d."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "Invocation of a function using an invalid SRM slot."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev"
CB_S-4-BADCARDTYPE
SEVERITY: Error
FORMAT: "Could not send trap %d from slot %d, sequence num %d."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "An attempt to generate a trap resulted in an error. The card type of the originating slot could not be identified."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev"
CB_S-4-INVVARBIND
SEVERITY: Error
FORMAT: "%s() Invalid Varbind type %d."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "An invalid varbind was detected during processing."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev"
CB_S-4-SEMCREATEERR
SEVERITY: Error
FORMAT: "%s() cntpSemBCreate() failed."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Attempt to create the control point semaphore failed."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev
5. dspsems"
CB_S-4-SEMTAKEERR
SEVERITY: Error
FORMAT: "%s() cntpSemBTake(BasisTrapSem 0x%x) failed."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Attempt to take the control point semaphore failed."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev
5. dsptasks
6. dspsems
7. dspsem <semaphore id of BasisTrapSem, 1>"
CB_S-4-SEMGIVEERR
SEVERITY: Error
FORMAT: "%s() cntpSemBGive(BasisTrapSem 0x%x) failed."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Attempt to give the control point semaphore failed."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev
5. dsptasks
6. dspsems
7. dspsem <semaphore id of BasisTrapSem, 1>"
CB_S-4-BUFTAKEERR
SEVERITY: Error
FORMAT: "%s() cntpMsgBufTake(dataLn=%d) failed."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Attempt to take a control point message buffer failed."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev
5. dsptasks
6. memshow"
CB_S-4-FRMBUFTAKEERR
SEVERITY: Error
FORMAT: "%s() Attempt to get SAR Buffer of len %d failed."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "Attempt to allocate a SAR Frame buffer failed."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev
5. dsptasks
6. memshow"
CB_S-7-TOOFEWVARBINDS
SEVERITY: Information
FORMAT: "Trap %d from slot %d has only %d of the mandated Robust Trap varbinds."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "An attempted trap generation was disallowed."
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
CB_S-7-NOTRAPS
SEVERITY: Information
FORMAT: "%s() Trap dropped because they are disallowed."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "An attempted trap generation was disallowed."
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
CB_S-6-TRAPLOG_WRAP
SEVERITY: Notice
FORMAT: "SNMP Trap log wrapped around."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "The RTM trap log buffer has wrapped around."
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
CB_S-6-RPMPORTCLOSED
SEVERITY: Notice
FORMAT: "Port for RPM slot=%d already closed."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "An attempt to close an RPM port failed because the port was already closed"
RECOMMENDED ACTION: No action required
REQUIRED INFO: No Required Info
CB_S-4-RPMOPENPORT
SEVERITY: Error
FORMAT: "Opening RPM Port %s for slot=%d failed."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "An attempt to open an RPM port failed."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev"
CB_S-4-OPENPORT
SEVERITY: Error
FORMAT: "%s() Opening Port %s failed."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "An attempt to open an IPC port failed."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev"
CB_S-4-PROCESSDEQ
SEVERITY: Error
FORMAT: "%s() Call to process_dequeue(0x%x) failed."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "A call to process_dequeue() failed."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev"
CB_S-4-CREATEWATCHEDQ
SEVERITY: Error
FORMAT: "%s() Call to create_watched_queue(%s) failed."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "A call to create_watched_queue() failed."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev"
CB_S-4-CREATENAMEDPORT
SEVERITY: Error
FORMAT: "%s() Call to ipc_create_named_port(%s) failed."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "A call to ipc_create_named_port() failed."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev"
CB_S-4-GETPAKMSGFAIL
SEVERITY: Error
FORMAT: "%s() Call to ipc_get_pak_message() failed."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "A call to ipc_get_pak_message() has failed."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev"
CB_S-4-IPCSENDMSGFAIL
SEVERITY: Error
FORMAT: "%s() Call to ipc_send_message() failed."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "A call to ipc_send_message() has failed."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev"
CB_S-4-MSG_TOO_SMALL
SEVERITY: Error
FORMAT: "%s() Message of len %d was rejected as too small."
FLAG: Stack Trace
THROTTLING: One Tick
EXPLANATION: "A message of a given length was considered too small."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.
REQUIRED INFO: "On PXM
1. dspcds
2. dsplog
3. dsperr
4. dsprev"
CB_S-4-SOIINITFAIL
SEVERITY: Error
FORMAT: "%s() Could not spawn PXM SOI Task."
FLAG: No Flag
THROTTLING: One Tick
EXPLANATION: "SNMP proxy task SOI spawn failed."
RECOMMENDED ACTION: Copy the error message exactly as it appears in the system log. Issue the 'dsperr' command from the PXM to gather data that may provide information to determine the nature of the error. If you cannot determine the nature of the error from the error message text or from the 'dsperr' output, call your Cisco technical support representative and provide the representative with the gathered information.