Table Of Contents
Messages and Recovery Procedures
ACL Messages
BUFFERMANAGER Messages
CHASSIS Messages
CHASSIS-2
CHASSIS-3
CHASSIS-4
CHASSIS-7
COMMONHWACLMAN Messages
COMMONHWACLMAN-4
COMMONSTUBMAN Messages
C4K_COMMONSTUBMAN-4
C4K_COMMONSTUBMAN-7
DAIMAN Messages
DHCP_SNOOPING Messages
DHCP_SNOOPING-3
DHCP_SNOOPING-4
DHCP_SNOOPING-6
DOT1X (802.1X) Messages
DOT1X-4
DOT1X-5
DTP Messages
DTP-4
DTP-5
EBM Messages
EBM-3
EBM-4
EC Messages
EC-4
EC-5
FLASH Messages
GBICMAN Messages
GBICMAN-3
HW Messages
HWACLMAN Messages
HWL2MAN Messages
HWNETFLOWMAN Messages
HWNETFLOWMAN-3
HWNETFLOWMAN-4
HWPORTMAN Messages
HWPORTMAN-4
HWPORTMAN-7
IDBMAN Messages
IDBMAN-3
IDBMAN-4
IDBMAN-6
ILCPROTOCOLERROR Messages
IOSACLMAN Messages
IOSDHCPSNOOPMAN Messages
IOSIGMPSNOOPMAN Messages
IOSINTF Messages
IOSINTF-4
IOSINTF-5
IOSIPROUTEMAN Messages
IOSIPROUTEMAN-3
IOSL2MAN Messages
IOSMODPORTMAN Messages
IOSMODPORTMAN-3
IOSMODPORTMAN-4
IOSMODPORTMAN-6
C4K_IOSREDUNDANCYMAN Messages
IOSSYS Message
IOSSYS-3
IOSSYS-4
IOSSYS-7
IOSSYSMAN Messages
IOSSYSMAN-0
IOSSYSMAN-3
IOSSYSMAN-4
IPROUTEMAN Messages
IPROUTEMAN-3
IPROUTEMAN-4
L2MAN
L3HWFORWARDING Messages
L3HWFORWADING-2
L3HWFORWADING-3
L3HWFORWADING-4
L3HWFORWADING-6
LINECARDMGMTPROTOCOL Messages
PKTPROCESSING Messages
PKTPROCESSING-3
PKTPROCESSING-4
PKTPROCESSING-5
PKTPROCESSING-7
Pluggable Messages
PM Messages
PM-2
PM-3
PM-4
PORTFANOUTASIC4X1000MAN Messages
PORTFANOUTASIC8X1000HW Messages
PORTFANOUTASIC8X1000HW-3
PORTFANOUTASIC8X1000HW-4
PORTFANOUTASIC8X1000HW-7
PORTFANOUTASIC8X100MAN Messages
PORTFANOUTASIC8X100MAN-4
PORTFANOUTASIC8X100MAN-7
QOS Messages
REDUNDANCY Messages
REDUNDANCY-2
REDUNDANCY-3
REDUNDANCY-4
REDUNDANCY-5
REDUNDANCY-6
S2W Messages
Service Module Messages
SFF8472 Messages
SFF8472-2
SFF8472-3
SFF8472-5
SFF8472_FLOAT
SPANTREE Messages
SPANTREE-2
SPANTREE-3
SPANTREE-4
SPANTREE-5
SPANTREE-6
SPANTREE-7
SPANTREE_FAST
SPANTREE_VLAN_SW Messages
Supervisor Messages
STORM_CONTROL Messages
STORE Messages
SUPERVISOR Messages
SUPERVISOR-2
SUPERVISOR-3
SUPERVISOR-4
SUPERVISOR-7
SWITCH-QOS-TB Messages
SW_DAI Messages
SW_DAI-4
SW_DAI-6
SW-VLAN Messages
SW-VLAN-3
SW-VLAN-4
SW-VLAN-6
SWITCHINGENGINEMAN Messages
SWITCHINGENGINEMAN-2
SWITCHINGENGINEMAN-3
SWITCHINGENGINEMAN-4
SWITCHMANAGER Messages
SWITCHMANAGER-3
SWITCHMANAGER-4
SWITCHMANAGER-5
SWNETFLOWMAN Messages
SWNETFLOWMAN-4
SWNETFLOWMAN-6
SYSMAN Messages
SYSMAN-2
SYSMAN-3
SYSMAN-4
TRANSCIEVER Messages
UFAST_MCAST_SW Messages
UFAST-3
UFAST-4
VQPCLIENT Messages
VQPCLIENT-2
VQPCLIENT-3
VQPCLIENT-7
WATCHDOG Messages
Messages and Recovery Procedures
This chapter lists and describes the Cisco IOS system error messages by facility for the Catalyst 4500 series switch. Within each facility, the messages are listed by severity levels 0 to 7. The highest severity level is 0, and the lowest severity level is 7. Each message is followed by an explanation and a recommended action, if available.
The system sends these error messages to the console (and, optionally, to a logging server on another system). Not all system error messages indicate problems with your system; some messages are purely informational, while other messages help diagnose problems with communication lines, internal hardware, or the system software.
Note
The messages listed in this chapter do not include the date/time stamp designation; the date/time stamp designation is displayed only if the software is configured for system log messaging.
Note
Writing to a module's serial EEPROM is not standard practice; when the module comes from the factory, the serial EEPROM is set to the correct values. We do not recommend that you change the factory defaults, because this action can cause the module to malfunction.
If the explanation that is provided for a given command does not sufficiently explain your problem and no recommended action is given, copy the error message exactly as it appears on the console or in the system log.
You should research and attempt to resolve the error using the Output Interpreter at this URL: https://www.cisco.com/cgi-bin/Support/OutputInterpreter/home.pl.
You can also enter the show tech-support command to gather additional information about the error. If the error message text, information from the Output Interpreter, or output from the show tech-support command do not help you solve the problem, contact your technical support representative and provide the representative with the information that you have gathered. For detailed information on how to contact your technical support representative, see the "Obtaining Technical Assistance" section.
ACL Messages
This section contains the access control list (ACL) message.
Error Message C4K_ACL-4-OUTOFMEMORY:Out of Memory while allocating
[char]
Explanation The software failed to allocate memory for the given object while
processing ACLs. The configuration might have exceeded its maximum limit.
If so, the feature using this ACL will not work.
Recommended Action If it is mandatory that the feature work normally, remove
other unwanted features that require ACLs and retry the operation. If the
problem persists, contact your technical support representative.
BUFFERMANAGER Messages
This section contains the memory buffer management (BUFFERMANAGER) message.
Error Message C4K_BUFFERMANAGER-3-OUTOFVBUFS: Have run out of
vbufs (internal buffers)
Explanation The switch ran out of the internal memory buffers that are used
for various tasks. This error is unusual because the internal buffers are used
for only a short time, released, and then available for reuse. Typically, this
condition is transitory.
Recommended Action If the message persists, reboot the switch.
CHASSIS Messages
This section contains the chassis (CHASSIS) messages.
CHASSIS-2
Error Message C4K_CHASSIS-2-INLINEPOWEROFF:Inline power to the
switch has been turned off
Explanation Software detected that the pass-through current is disabled. This
condition will cause all phones drawing PoE from the switch to be powered
off.
Recommended Action If you want PoE, verify that the in-line power switch on
the power supply is turned on.
Error Message C4K_CHASSIS-2-INSUFFICIENTFANSDETECTED:Too few
working fans in fan tray, the chassis will overheat. If not
resolved, in 4 minutes all line cards will be placed into
Reset-Mode
Explanation Two or more fans in the system fan tray or power supplies are
malfunctioning, or the fan tray has been removed. Although this is a minor
alarm, system components could overheat and shut down.
Recommended Action Replace the system fan tray or broken fans.
Error Message C4K_CHASSIS-2-INSUFFICIENTFANSSHUTDOWN: Resetting
linecards due to fan tray failure
Explanation One or more required fans in the fan tray or the power supplies is
malfunctioning. Software reset the modules to reduce heat generation.
Recommended Action Replace the broken fans as soon as possible.
Error Message C4K_CHASSIS-2-INSUFFICIENTPOWERDETECTED:Insufficien
t power available for the current chassis configuration
Explanation The current chassis configuration exceeds power availability. If
this condition persists, software will reset the modules.
Recommended Action If the power availability problem persists and impacts
performance, replace the power supply with a larger capacity power supply.
Error Message C4K_CHASSIS-2-INSUFFICIENTPOWERSHUTDOWN:Holding
module in slot [dec] in reset, due to insufficient power
Explanation The switch was using more power than is available for the
allowed time interval. Software reset the modules to reduce power
consumption.
Recommended Action If the power availability problem persists and impacts
performance, replace the power supply with a power supply with a larger
capacity.
Error Message C4K_CHASSIS-2-OVERHEATINGSHUTDOWN:Resetting
linecards due to critical temperature
Explanation The switch is now warmer than its maximum allowable operating
temperature. Software will reset modules to reduce heat generation.
Recommended Action Verify that the switch is in the proper operating
environment and that the fans are functioning properly.
CHASSIS-3
Error Message C4K_CHASSIS-3-BADGBIC:Port [char]: Gbic's seeprom is
bad, try reinserting: vendor: [char], p/n: [char], s/n: [char]
Explanation A Gigabit Interface Converter (GBIC) with a serial EEPROM
was detected in the port specified in the message. Although the serial
EEPROM's contents were readable, the contents are not valid (possibly due
to a bad checksum).
The message lists the vendor, part number, and serial number from the GBIC's serial EEPROM. This message appears if the GBIC is not seated correctly.
Recommended Action Remove and reinsert the GBIC. If this message appears
repeatedly, insert the GBIC in another port to verify that it is the GBIC and
not the port that is bad. If the GBIC fails in a different port, return the GBIC
to your technical support representative for reprogramming. If the GBIC
works in the other ports but not in the original port, the original port is bad,
and you need to return the module to your technical support representative for
repair. To test the port further, insert a different GBIC into the port. If the
other GBIC fails in that port, the port is bad.
Error Message C4K_CHASSIS-3-BADMACRANGEINSPROM:Module [dec]'s
serial eeprom contains [dec] mac addresses, but needs [dec]
Explanation The contents of the module's serial EEPROM is incorrect, and
the range is smaller than the number of front-panel ports for the module. The
module's serial EEPROM contains a range of MAC addresses for this
module, and the range should contain the same number of MAC addresses as
the number of front-panel ports because each MAC address corresponds to a
front-panel port.
Recommended Action Contact your technical support representative; you will
likely have to return the module to Cisco to reprogram the serial EEPROM.
Error Message C4K_CHASSIS-3-DAUGHTERCARDSEEPROMREADFAILED:Failed
to read the serial eeprom on module [dec], daughter card [dec]
Explanation The serial EEPROM for a daughter card on the specified module
is unreadable. Because reading this EEPROM is the only way to determine
the type of card, the card remains offline, as if it was not installed on the
module.
Recommended Action Remove the module, and then remove and reseat the
daughter card in the module. If this message reappears after you reinsert the
module into the switch, the serial EEPROM might be bad. Contact your
technical support representative; you will likely have to return the module to
Cisco to reprogram or replace the serial EEPROM.
Error Message C4K_CHASSIS-3-GBICSEEPROMREADFAILED:Failed to read
gbic serial eeprom on port [char], try reinserting
Explanation A Gigabit Interface Converter (GBIC) was detected in the
specified port, but the contents of the GBIC's EEPROM was unreadable. The
EEPROM must be read to determine the GBIC type. The read might fail if the
GBIC is not seated correctly.
Recommended Action Remove and reinsert the GBIC. If this message
reappears, insert the GBIC in another port to verify that it is the GBIC and not
the port that is bad. If the GBIC fails in the other port, return the GBIC to your
technical support representative for reprogramming. If the GBIC works in the
other ports but not in the original port, the original port is bad, and you need
to return the module to your technical support representative for repair. To
test the port further, insert a different GBIC into the port. If the other GBIC
also fails in that port, the port is bad.
Error Message C4K_CHASSIS-3-INSUFFICIENTPOWER:Insufficient power
to bring up module in slot [dec]
Explanation The module type was identified, but the switch does not have
sufficient power to bring the module up. The switch holds the module in reset
mode to consume less power.
Recommended Action Add or replace a power supply to expand the power
capacity of the chassis.
Error Message C4K_CHASSIS-3-INSUFFICIENTPOWERSUPPLIESDETECTED:
Insufficient power supplies present for specified configuration
Explanation The system software detected that the current chassis
configuration has fewer power supplies than required for the existing
configuration.
Recommended Action Add a power supply to meet the needs of the current
chassis configuration.
Error Message C4K_CHASSIS-3-LINECARDMUXBUFFERTOSUPALIGNMENTWRONG:
Linecard [dec] MuxBuffers aligned towards supervisor in slot
[dec] instead of [dec]
Explanation The mux buffers that work with the switching module in the
mentioned slot are configured to work with the standby supervisor engine.
The switching module is completely unusable in this condition.
Recommended Action Try removing and reinserting the affected switching
module. If that doesn't work, try resetting the switch. If the problem persists,
contact your technical support representative.
Error Message C4K_CHASSIS-3-MIXINVOLTAGEDETECTED:Power supplies in
the chassis are receiving different voltage inputs
Explanation All the inputs to a chassis must be at the same voltage. Mixed
voltage inputs are not supported.
Recommended Action Change the power supplied to the switch so that all
inputs to the chassis are of the same type.
Error Message C4K_SUPERVISOR-3-MUXBUFFERREADSUPERVISORSELECTIONFA
ILED:Failed to read linecard [char] muxbuffer supervisor
selection register
Explanation The active supervisor tried to read alignment information for the
switching module slot's mux buffer from the chassis mux buffer module, but
was unable to do so. This information is needed to make sure that switching
module slot's mux buffer is aligned towards the active supervisor engine.
Recommended Action If this message appears only once for a switching
module, this could be a transient error and no action is required. If this
message appears repeatedly (once every 5 minutes) on one or more switching
modules please contact your technical support representative to replace the
supervisor engine and chassis.
Error Message C4K_SUPERVISOR-3-MUXMAYMISALIGN:Linecard
Mux-buffers may mis-align to incorrect supervisor due to reset
with other supervisor desires to be active
Explanation While resetting the switching modules and taking them out of
reset the other supervisor is trying to become active using hardware
hot-standby logic. This may cause incorrect alignment of switching module
mux-buffers to use the non-active supervisor, and the switch will not be able
to pass traffic until the alignment is reset.
Recommended Action Reset the other supervisor using the redundancy reload
peer command, and contact your technical support representative to report
the failure.
Error Message C4K_CHASSIS-3-LINECARDNOTVALIDINSLOT: Module (Field
Replaceable Unit minor type [dec]) is not supported in slot [dec]
Explanation The supervisor engine identified the type, but the switching
module cannot be supported in this slot due to the insufficient number of
backplane ports in this slot.
Recommended Action This is an informational message only. No action is
required. If possible, move the switching module to another slot, and use a
supported module in the original slot.
Error Message C4K_CHASSIS-3-LINECARDSEEPROMREADFAILED:Failed to
read module [dec]'s serial eeprom, try reinserting module
Explanation The switch cannot read the serial EEPROM of the specified
module, and the module will not boot because the EEPROM failed to identify
the module type. The read might fail if the module is not seated correctly in
the slot.
Recommended Action Remove and reinsert the module. If this message
reappears, reboot the switch. If the problem persists, contact your technical
support representative. You will likely have to return the module to Cisco to
reprogram or replace the serial EEPROM.
Error Message C4K_CHASSIS-3-LINECARDSEEPROMWRITEFAILED:Failed to
write module [dec]'s serial eeprom
Explanation A write operation to the serial EEPROM failed. The write might
fail if the module is not seated correctly in the slot.
Recommended Action Remove and reinsert the module. If this message
reappears, reboot the switch. If the problem persists, contact your technical
support representative. You will likely have to return the module to Cisco to
reprogram or replace the serial EEPROM.
Error Message C4K_CHASSIS-3-MIXINPOWERDETECTED:Power supplies in
the chassis are of different types (AC/DC) or wattage
Explanation The software detected different kinds of power supplies in the
chassis. In a Catalyst 4006 chassis, the power values default to the wattage of
the weakest power supply. If you mix power supplies in a Catalyst 4500 series
chassis, the switch will use the power supply in power supply bay 1 (PS1) and
ignore the power supply in power supply bay 2 (PS2). We do not recommend
mixing power supplies of different wattages.
Recommended Action Verify that both power supplies are the same kind and
wattage. Replace a power supply if necessary.
Error Message C4K_CHASSIS-3-MIXINVOLTAGEDETECTED:Power supplies in
the chassis are receiving different voltage inputs
Explanation All the inputs to a chassis must be at the same voltage. Mixed
voltage inputs are not supported.
Recommended Action Replace one of the power supplies so that the power
supplies used are of the same model.
Error Message C4K_CHASSIS-3-MODULENOTSUPPORTHALF:Module [dec] does
not support 10 Mb or 100Mb Half duplex operation. Please have
your card upgraded if you need half duplex operation.
Explanation Some preproduction switching modules have interfaces that do
not work in half-duplex mode. This module is probably a prototype.
Recommended Action Contact your technical support representative; you will
likely have to return the module to Cisco.
Error Message C4K_CHASSIS-3-ONLYLXSFPSALLOWED:Port [char] has a
non-LX SFP, which is not supported
Explanation The WS-X4448-GB-LX module supports only LX SFPs. It marks
any other type of Small Form-Factor Pluggable (SFP) as faulty.
Recommended Action Replace the SFP with an LX SFP that Cisco supports.
Error Message C4K_CHASSIS-3-OUTOFMEMORY:Ran out of memory - cannot
allocate internal buffers
Explanation The switch ran out of memory in the temporary buffers.
Recommended Action If this message reappears, reboot the switch.
Error Message C4K_CHASSIS-3-SEEPROMREADFAILEDAFTERWRITE:Error
reading back module [dec]s serial EEPROM data after write
Explanation After writing a module's serial EEPROM in response to a CLI
request, the switch tried to read it back in, to ensure that the correct values
were written out. What the switch read back in differs from what the switch
wrote out. The read or write might fail if the module is not seated correctly in
the slot.
Recommended Action Remove and reinsert the module. If that does not work,
reboot the switch. If the problem persists, contact your technical support
representative. You will likely have to return the module to Cisco to
reprogram or replace the serial EEPROM.
Note
Writing the module's serial EEPROM is not standard practice; when the module comes from the factory, its serial EEPROM is set to the correct values. We do not recommend that you change the factory defaults, because this action could cause the module to malfunction.
Error Message C4K_CHASSIS-3-SFPCRCINTEGRITYCHECKFAILED:SFP
integrity check on port [char] failed: bad crc
Explanation The checksum of the SFP SEEPROM is not valid, indicating a
bad or non-Cisco SFP.Only Cisco-qualified Small Form-factor Pluggables
(SFPs) are supported. Other SFPs place the associated port in a faulty status.
Recommended Action Replace the SFP with an SFP that Cisco supports.
Error Message C4K_CHASSIS-3-SFPINTEGRITYCHECKFAILED:SFP integrity
check on port [char] failed: bad key
Explanation Only Cisco-qualified Small Form-factor Pluggables (SFPs) are
supported. Other SFPs place the associated port in a faulty status.
Recommended Action Replace the SFP with an SFP that Cisco supports.
Error Message C4K_CHASSIS-3-SFPSERIALINTEGRITYCHECKFAILED:SFPs on
ports [char] and [char] have duplicate serial numbers
Explanation Only Cisco-qualified Small Form-factor Pluggables (SFPs) are
supported. Other SFPs place the associated port in the faulty status.
All SFPs must have a unique serial number. If this message appears you likely have a cloned SFP SEEPROM.
Recommended Action Replace the SFP with an SFP that Cisco supports.
Error Message C4K_CHASSIS-3-STUBPHYMISMATCH: Stub type mismatch:
stub [dec]/[dec] is type [dec], should be type [dec]
Explanation The stubs have non-matching physical types for the specified
module.
Recommended Action Verify that the physical types for every stub on the
module match.
Error Message C4K_CHASSIS-3-TEMPERATURESENSORREADFAILED: Failed to
read the supervisor temperature sensor
Explanation The temperature sensor on the supervisor engine cannot be read.
If the chassis becomes overheated, this condition will not be reported.
Recommended Action If this message appears only once, this error could be
transient and no action is required. If this message appears repeatedly (once
every 30 minutes), inspect and, if necessary, replace the temperature sensor
on the supervisor engine.
Error Message C4K_CHASSIS-3-UNKNOWNLINECARD:Unknown module (Field
Replaceable Unit minor type [dec]) in slot [dec]
Explanation The module's serial EEPROM was readable, and your software
image does not recognize this module. A software upgrade is necessary.
Recommended Action Upgrade the software to a version that is compatible
with the module.
CHASSIS-4
Error Message C4K_CHASSIS-4-CANTWRITESUPERVISORSPROM:Writing the
supervisor's SPROM is not supported
Explanation Rewriting the supervisor engine's serial programmable read-only
memory (SPROM) is not allowed, because if it is done incorrectly, it could
make the system unusable.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_CHASSIS-4-INLINEPOWERRESTORED:Resuming normal
phone operation since inline power has been restored
Explanation PoE to the switch was restored, and normal phone operation will
resume.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_CHASSIS-4-OVERHEATINGOVER:Resuming normal
operation after return to acceptable temperatures.
Explanation The unit's modules were reset to reduce heat generation, because
the unit reached a critical temperature. The switch is now cool enough to
return to normal operation.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_CHASSIS-4-SUFFICIENTFANSRESTORED: Resuming
normal operation after restoration of adequate fan cooling
Explanation The modules were reset to reduce heat generation because there
were not enough working fans. Adequate fan cooling is now restored, and the
switch will resume normal operation.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_CHASSIS-4-SUFFICIENTMODULEPOWERRESTORED:Module
in slot [dec] resuming normal operation after restoration of
adequate power
Explanation The module was reset to conserve power because the system had
inadequate power available. The switch now has adequate power and is
resuming normal operation.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_CHASSIS-4-SUFFICIENTPOWERRESTORED:Resuming
normal operation after restoration of adequate power
Explanation The switch reset the modules to conserve power, but it now has
adequate power and will resume normal operation.
Recommended Action This is an informational message only. No action is
required.
CHASSIS-7
Error Message C4K_CHASSIS-7-GBICINSERTED:Port [char]: New gbic
inserted: vendor: [char], p/n: [char], s/n: [char]
Explanation A Gigabit Interface Converter (GBIC) with a serial EEPROM
was detected in the specified interface. The message lists the vendor, part
number, and serial number from the GBIC's serial EEPROM.
Recommended Action This is an informational message only. No action is
required.
COMMONHWACLMAN Messages
This section contains the common hardware ACL management (COMMONHWACLMAN) messages.
COMMONHWACLMAN-4
Error Message C4K_COMMONHWACLMAN-4-ALLACLINHW:All configured ACLs
now fully loaded in hardware TCAM - hardware switching / QoS
restored
Explanation All ACL-based features are now successfully loaded. Packets
that were previously processed in software due to the prior loading failure
will now be processed in hardware.
Note
If the features were policy maps, then QoS will be reenabled on all applicable interfaces.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_COMMONHWACLMAN-4-FAILEDTOSWITCHPORTTAGS:Failed
to switch port tags, old tag: [object-info] new tag:
[object-info] . Software paths: [dec] Hardware paths: [dec]
Explanation The software failed to switch tags. This error could be transient.
The ACL that you were trying to configure will not become active.
Recommended Action Detaching and reattaching the ACLs (and policies)
might solve the problem.
Error Message C4K_COMMONHWACLMAN-4-FAILEDTOSWITCHVLANTAGS:Failed
to switch vlan tags, old tag: [object-info] new tag:
[object-info] . Software paths: [dec] Hardware paths: [dec]
Explanation The software failed to switch tags. This error could be transient.
The ACL that you were trying to configure will not become active.
Recommended Action Detaching and reattaching the ACLs (and policies)
might solve the problem.
Error Message C4K_COMMONHWACLMAN-4-HWPROGSUCCESS: [char] [char] -
now fully loaded in hardware TCAM
Explanation ACL-based features are now successfully loaded. Packets that
were previously processed in software due to a prior loading failure will now
be processed in hardware. If the feature is a policy map, then QOS will be
reenabled on the specific interface.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_COMMONHWACLMAN-4-OUTOFPATHS: Could not allocate
path for ( [object-info] )
Explanation There are too many ports or VLANs using ACLs. The ACLs
might not work correctly.
Recommended Action Remove unnecessary ACLs from some interfaces.
Error Message C4K_COMMONHWACLMAN-4-OUTOFTAGS:No more free tags
available for path ( [object-info] )
Explanation All available tags are being used or are about to be used. Because
you have configured either too many features using ACLs or features using
ACLs that are attached to ports or VLANs, the hardware forwards the packets
to CPU for ACL processing.
Recommended Action Remove unnecessary ACLs from some interfaces.
Error Message C4K_COMMONHWACLMAN-4-PERMITALL: Out of resources for
Qos, permit all for [object-info]
Explanation The switch is running out of hardware CAM resources. All
packets are permitted, and QoS is applied.
Recommended Action Remove unnecessary ACLs from some interfaces.
Error Message C4K_COMMONHWACLMAN-4-PORTBASEDACLSDISABLED: Output
Port Acl [char] has been disabled on port [char]
Explanation The output port ACL is disabled on the interface because there
are not enough hardware resources or there are ACEs that require CPU
processing of packets.
The port ACL is disabled and displays a warning message because the software cannot handle the output port ACLs.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_COMMONHWACLMAN-4-PUNTTOSOFTWARE:Out of
resources, punt packets to sw for [object-info]
Explanation The hardware content-addressable memory (CAM) resources
have been depleted. The hardware forwards the packets to the software for
ACL processing.
Recommended Action Remove unnecessary ACLs from some interfaces.
COMMONSTUBMAN Messages
This section contains the Catalyst 4500 series ASIC-specific messages.
C4K_COMMONSTUBMAN-4
Error Message C4K_COMMONSTUBMAN-4-DIAGSFAILED: [char] failed
diagnostics
Explanation An ASIC in slot [char] failed diagnostics.
Recommended Action Contact your technical support representative.
Error Message C4K_COMMONSTUBMAN-4-FAILEDTOSENDLOOPBACKTRIES:
[char] port [dec] failed to send packet in [dec] tries
Explanation An ASIC in slot [char] was unable to send a loopback packet on
port [dec] and this is the [dec]th time it tried to send and failed. This suggests
that the switch is out of memory. The software will attempt to send a loopback
packet only three times.
Recommended Action Contact your technical support representative.
Error Message C4K_COMMONSTUBMAN-4-UNEXPECTEDLOOPBACK: [char] sent
out a loopback packet on port [dec], but it came back on port
[dec]
Explanation The ASIC diagnostics for slot [char] sent a loopback packet out
port [dec] and it came back on another port [dec]. This is unexpected because
the loopback is done within the hardware.
Recommended Action Contact your technical support representative.
C4K_COMMONSTUBMAN-7
Error Message C4K_COMMONSTUBMAN-7-LOSTPACKET: [char] port [dec]
lost a packet
Explanation A loopback packet was lost during online diagnostics of an ASIC
in slot [char].
Recommended Action This is an informational message only. No action is
required.
DAIMAN Messages
This section contains the Catalyst 4500 series-specific dynamic ARP inspection (DAIMAN) message.
Error Message C4K_DAIMAN-4-OUTOFRESOURCES:Resources for
constructing ACLs, are not available.
Explanation Software resources are not available to set up the hardware to
redirect ARP packets to the software. Dynamic ARP inspection will not work
if this message displays.
Recommended Action Remove unnecessary ACLs from some interfaces.
DHCP_SNOOPING Messages
This section contains the DHCP snooping (DHCP_SNOOPING) messages.
DHCP_SNOOPING-3
Error Message DHCP_SNOOPING-3-DHCP_SNOOPING_INTERNAL_ERROR: DHCP
Snooping internal error
Explanation A software sanity check failed in the DHCP snooping process.
Recommended Action This is an informational message only. No action is
required.
DHCP_SNOOPING-4
Error Message DHCP_SNOOPING-4-AGENT_OPERATION_FAILED_N: DHCP
snooping binding transfer failed([dec]). [chars]
Explanation This message is logged once every 30 minutes and displays the
[dec] number of failures that occurred for a given reason [chars] during the
past 30 minutes.
This message is a rate-limited version of the DHCP_SNOOPING-4-AGENT_OPERATION_FAILED message.
Recommended Action Based on the reason for the error [chars], look at the
explanation for the DHCP_SNOOPING-4-AGENT_OPERATION_FAILED
message, and take the appropriate action.
Error Message DHCP_SNOOPING-4-AGENT_OPERATION_FAILED: DHCP
snooping binding transfer failed. Unable to access URL.
Explanation The DHCP snooping binding transfer failed. The reason for
failure can include any of the following:
–
The URL is not available to use.
–
Not enough memory is available for creating an agent.
–
The number of agents reached the maximum supported limit.
–
The switch is unable to create an agent.
–
The switch is unable to access the URL.
–
The switch is unable to start the agent.
–
The Abort timer expired.
–
The number of entries exceeded the maximum supported limit.
–
An error occurred when reading the remote database.
–
An error occurred while writing to the remote database.
–
DHCP snooping expected more data during the read.
–
The string type is invalid.
–
The version string type is invalid.
–
DHCP snooping is expecting a new line in the database.
–
'TYPE' was not found in the remote database.
–
'VERSION' was not found in the remote database.
–
'BEGIN' was not found in the remote database.
–
'END' was not found in the remote database.
–
The type string was not found in the remote database.
–
The version string was not found in the remote database.
–
The checksum failed upon entry into the remote database.
Recommended Action Based on the reason for the error (listed above), take the
appropriate action.
Error Message DHCP_SNOOPING-4-DHCP_SNOOPING_ERRDISABLE_WARNING:
DHCP Snooping received [dec] DHCP packets on interface [char]
Explanation DHCP snooping detected a DHCP packet rate-limit violation on
the specified interface. The interface will be placed in the errdisable state.
Recommended Action This is an informational message only. No action is
required.
Error Message DHCP_SNOOPING-4-DHCP_SNOOPING_PVLAN_WARNING: DHCP
Snooping configuration may not take effect on secondary vlan
[dec]. [char]
Explanation DHCP snooping configuration on the primary VLAN
automatically propagates to all secondary VLANs if private VLANs are
enabled.
Recommended Action This is an informational message only. No action is
required.
Error Message DHCP_SNOOPING-4-IP_SOURCE_BINDING_PVLAN_WARNING: IP
source filter may not take effect on secondary vlan [dec] where
IP source binding is configured. [char]
Explanation The IP source filter on the primary VLAN automatically
propagates to all secondary VLANs if private VLANs are enabled.
Recommended Action Reconfigure the IP source binding to a known
functioning VLAN.
Error Message DHCP_SNOOPING-4-IP_SOURCE_BINDING_NON_EXISTING_VLAN
_WARNING: IP source binding is configured on non existing vlan
[dec].
Explanation IP source binding was configured on a VLAN that has not yet
been configured.
Recommended Action This is an informational message only. No action is
required. It may persist unless you define the VLAN in question and then
reapply the IP source binding. If you see this message regarding a VLAN that
is correctly configured, contact your technical support representative.
Error Message DHCP_SNOOPING-4-QUEUE_FULL: Fail to enqueue DHCP
packet into processing queue: [char]
Explanation DHCP packets are coming into the CPU at a much higher rate
than the DHCP snooping process can handle them. These unhandled DHCP
packets will be dropped to prevent a denial of service attack.
Recommended Action This is an informational message only. No action is
required.
Error Message DHCP_SNOOPING-4-SSO_SYNC_ACK_ERROR:Error is
encountered in processing acknowledgement for DHCP snooping
binding sync [char]. ack message txn id:[hex]
Explanation There was an error in handling the DHCP synchronization
acknowledgement. In most of these cases, the ACK message is ignored.
Recommended Action This is an informational message only. No action is
required.
Error Message DHCP_SNOOPING-4-STANDBY_AGENT_OPERATION_FAILED:
DHCP snooping binding transfer failed on the Standby Supervisor.
[char]
Explanation If the DHCP snooping database supporting SSO is configured as
a local device, both supervisor engines will update their database whenever
there is an update regarding bindings. This error message is an indication that
a snooping database update on the standby supervisor engine failed in the
manner mentioned. The most likely cause for these problems is if the
snooping database is configured as a slot0 device, but functioning compact
flash memory is only present on the active supervisor engine's slot0 while the
standby supervisor engine's slot0 is empty or faulty. Possible variations in
output include:
"URL not available for use."
"Not enough memory available for creating agent."
"Number of agents reached maximum supported limit."
"Unable to create agent."
"Unable to access URL."
"Unable to start agent."
"Abort timer expiry."
"Number of entries exceeded max supported limit."
"Unable to transfer bindings. Memory allocation failure."
"Error reading the remote database."
"Error writing to remote database."
"Expected more data on read."
"Type string invalid."
"Version string invalid."
"New line expected in database."
"\'TYPE\' not found in remote database."
"\'VERSION\' not found in remote database."
"\'BEGIN \' not found in remote database."
"\'END\' not found in remote database."
"Type string not found in remote database."
"Version string not found in remote database."
"Checksum failed on an entry in remote database."
"No failure recorded."
Recommended Action The switch will continue to function if no action is
taken, but the redundancy features will be compromised until both active and
standby supervisor engines have working flash memory available. Replace or
insert flash memory into the supervisor engine that lacks it if needed.
DHCP_SNOOPING-6
Error Message DHCP_SNOOPING-6-AGENT_OPERATION_SUCCEEDED: DHCP
snooping database [char] succeeded.
Explanation DHCP snooping has successfully read or written to the database.
Recommended Action This is an informational message only. No action is
required.
Error Message DHCP_SNOOPING-6-BINDING_COLLISION: Binding
collision. [dec] bindings ignored
Explanation One or more bindings from the database file has a MAC address
and VLAN combination for which the switch already holds DHCP snooping
bindings.
Recommended Action This is an informational message only. No action is
required.
Error Message DHCP_SNOOPING-6-INTERFACE_NOT_VALID: Interface not
valid. [dec] bindings ignored.
Explanation The interface that is listed in the database file's binding is not
available, that the interface is a router port, or that the interface is a DHCP
snooping-trusted Layer 2 interface.
Recommended Action This is an informational message only. No action is
required.
Error Message DHCP_SNOOPING-6-LEASE_EXPIRED: Lease Expired. [dec]
bindings ignored.
Explanation The DHCP lease expired for the given number of bindings from
the database file.
Recommended Action This is an informational message only. No action is
required.
Error Message DHCP_SNOOPING-6-PARSE_FAILURE: Parsing failed for
[dec] bindings.
Explanation The database read operation failed for the stated number of
bindings.
Recommended Action This is an informational message only. No action is
required.
Error Message DHCP_SNOOPING-6-VLAN_NOT_SUPPORTED: Vlan not
supported. [dec] bindings ignored.
Explanation The VLAN is not supported by DHCP snooping.
Recommended Action This is an informational message only. No action is
required.
DOT1X (802.1X) Messages
This section contains the IEEE 802.1X-related (DOT1X) port-based authentication messages.
DOT1X-4
Error Message DOT1X-4-MEM_UNAVAIL:Memory was not available to
perform the 802.1X action
Explanation Due to a lack of memory 802.1X cannot perform authentication,
so it will not be enabled.
Recommended Action Reduce other system activity to ease memory demands.
Install more memory, if necessary.
Error Message DOT1X-4-MSG_ERR: Unknown message event received
Explanation Due to an unexpected event the 802.1X process received an
unknown message.
Recommended Action Restart 802.1X in case the condition is transient. If the
restart fails, reload the device.
Error Message DOT1X-4-PROC_START_ERR: DOT1X unable to start
Explanation For unknown reasons 802.1X cannot start.
Recommended Action Restart 802.1X by entering the dot1x
system-auth-control command in case the condition is transient. If the
restart fails, reload the device.
Error Message DOT1X-4-UNKN_ERR: An unknown operational error
occurred
Explanation Due to an unexpected internal error 802.1X cannot operate.
Recommended Action Reload the device.
DOT1X-5
Error Message DOT1X-5-ERR_CHANNELLING: Dot1x can not be enabled on
Channelling ports
Explanation Because this port is a bundled port dot1x port-control cannot
enter enable state with auto mode or disable state with force-authorized
mode.
Recommended Action Disable channeling on the interface, and then enable
802.1X.
Error Message DOT1X-5-ERR_VVID_NOT_SUPPORTED: Dot1x can not be
enabled on this port with Voice VLAN configured.
Explanation Dot1x with voice VLAN is not supported on this port on this
platform.
Recommended Action Remove the voice VLAN configuration on this port and
retry the Dot1x operation.
Error Message DOT1X-5-ERR_DYNAMIC: Dot1x can not be enabled on
Dynamic ports
Explanation Because this port is a dynamic port dot1x port-control cannot
enter enable state with auto mode (or disable state with force-authorized
mode).
Recommended Action Disable the dynamic mode on the interface, and then
enable 802.1X.
Error Message DOT1X-5-ERR_DYNAMIC_VLAN: Dot1x can not be enabled on
dynamic VLAN ports.
Explanation Because this port is a dynamic VLAN port dot1x port-control
cannot enter enable state with auto mode (or disable state with
force-authorized mode).
Recommended Action Disable the dynamic VLAN on the interface, and then
enable 802.1X.
Error Message DOT1X-5-ERR_INVALID_AAA_ATTR: Got invalid AAA
attribute settings [char]
Explanation The authorization settings obtained are either unsupported or
invalid.
Recommended Action Change the value to reflect the correct settings.
Error Message DOT1X-5-ERR_INVALID_TUNNEL_MEDIUM_TYPE: Got an
invalid value [char] for TUNNEL_MEDIUM_TYPE [char]
Explanation The provided TUNNEL_MEDIUM_TYPE is either unsupported
or invalid.
Recommended Action Change the value to reflect the correct tunnel medium
type.
Error Message DOT1X-5-ERR_INVALID_TUNNEL_TYPE: Got an invalid
value of [char] for TUNNEL_TYPE [char]
Explanation The provided TUNNEL_TYPE is either unsupported or invalid.
Recommended Action Change the value to reflect the correct tunnel type.
Error Message DOT1X-5-ERR_MULTI_ACCESS:Dot1x can not be enabled on
voice vlan configured ports.
Explanation 802.1X cannot be enabled on a voice VLAN-configured port.
This condition is caused by trying to set 802.1X port control to auto or
force-unauthorized (force_unauth) mode on a voice VLAN-configured
port, which is not allowed.
Recommended Action Disable voice VLAN on the interface, and then enable
802.1X.
Error Message DOT1X-5-ERR_PER_USR_IP_ACL: Applied per-user IP ACL
was unsuccessful on interface [char]
Explanation Dot1x could not successfully apply per-user IP ACL, one
possible cause could be an invalid pub from the RADIUS server.
Recommended Action Reconfigure the RADIUS pub.
Error Message DOT1X-5-ERR_PER_USR_MAC_ACL: Applied per-user MAC
ACL was unsuccessful on interface [char]
Explanation 802.1X cannot successfully apply a per-user MAC ACL possibly
because of an invalid pub from the RADIUS server.
Recommended Action Examine the RADIUS pub and configure a correct one.
Error Message DOT1X-5-ERR_PROTO_TUNNELLING:Dot1x can not be
enabled on protocol tunnelling enabled ports.
Explanation 802.1X cannot be enabled on the protocol tunneling-enabled
port. This condition is caused by trying to set 802.1X port control to auto or
force-unauthorized (force_unauth) mode on a protocol tunneling-enabled
port, which is not allowed.
Recommended Action Disable protocol tunneling on the interface, and then
enable 802.1X.
Error Message DOT1X-5-ERR_PVLAN_EQ_VVLAN: Dot1x can not be enabled
on a port with Access VLAN equal to Voice VLAN.
Explanation The switch cannot enable 802.1X on the interface that uses the
same VLAN number for the access VLAN and the voice VLAN. This
condition was caused by trying to set 802.1X port-control to auto or
force-unauthorized (force_unauth) mode on a voice VLAN that uses the
same VLAN as the access VLAN, which is not allowed.
Recommended Action Change the voice VLAN or access VLAN on the
interface, and retry the 802.1X operation.
Error Message DOT1X-5-ERR_PVLAN_TRUNK:Dot1x can not be enabled on
private VLAN trunk ports.
Explanation 802.1X cannot coexist with private VLAN trunking on the same
port.
Recommended Action This is an informational message only. No action is
required.
Error Message DOT1X-5-ERR_RADIUSVLAN_EQ_VVLAN: RADIUS attempted to
assign a VLAN to Dot1x port [char] whose Voice VLAN is same as
Access Vlan
Explanation The RADIUS server attempted to assign a VLAN to a supplicant
on an interface whose voice VLAN settings are identical to the access VLAN
settings.
Recommended Action Update the RADIUS configuration so that the access
VLAN settings are not identical to the voice VLAN settings for this interface.
Error Message DOT1X-5-ERR_RSPAN_VLAN:Dot1x can not be enabled on
ports configured in Remote SPAN vlan.
Explanation 802.1X cannot be enabled on the remote SPAN VLAN port. This
condition is caused by trying to set 802.1X port control to auto or
force-unauthorized (force_unauth) mode on a port that is in the remote
SPAN VLAN, which is not allowed.
Recommended Action Disable remove span on the VLAN, and then enable
802.1X.
Error Message DOT1X-5-ERR_SPANDST: Dot1x can not be enabled on
[char]. It is configured as a SPAN Dest port.
Explanation The switch was not able to configure Dot1x on a given port
because Dot1x and SPAN destination ports are mutually exclusive features.
Recommended Action Disable the SPAN destination port configuration the
reconfigure Dot1x on the port.
Error Message DOT1X-5-ERR_TRUNK: Dot1x can not be enabled on Trunk
port
Explanation Because this port is a trunk port dot1x port-control cannot enter
enable state with auto mode (or disable state with force-authorized mode).
Recommended Action Disable trunking on the interface, and then enable
802.1X.
Error Message DOT1X-5-ERR_TUNNEL:Dot1x can not be enabled on 802.1q
tunnelling enabled ports
Explanation 802.1X cannot be enabled on the dot1q tunneling-enabled port.
This condition is caused by trying to set 802.1X port control to auto or
force-unauthorized (force_unauth) mode on a 802.1Q tunnel-enabled port,
which is not allowed.
Recommended Action Disable 802.1Q tunneling on the interface, and then
enable 802.1X.
Error Message DOT1X-5-ERR_VLAN_INTERNAL: The VLAN [dec] is being
used internally and cannot be assigned for use on the Dot1x port
[char] Vlan
Explanation The VLAN is used internally and cannot be assigned on this port.
Recommended Action Update the configuration so that this VLAN is not used.
Error Message DOT1X-5-ERR_VLAN_INVALID: The VLAN [dec] is invalid
and cannot be assigned for use on the Dot1x port [char] Vlan
Explanation The VLAN specified is out of range and cannot be assigned on
this port.
Recommended Action Update the configuration to use a valid VLAN.
Error Message DOT1X-5-ERR_VLAN_NOT_ASSIGNABLE: RADIUS tried to
assign a VLAN to dot1x port [char] whose VLAN cannot be assigned
Explanation Because this port is configured so that a VLAN cannot be
changed, the RADIUS server failed when it attempted to assign a VLAN to a
client that is attached to this port. For example, this port could be a routed
port.
Recommended Action This is an informational message only. No action is
required.
Error Message DOT1X-5-ERR_VLAN_NOT_FOUND: RADIUS tried to assign
non-existent VLAN name [char] to dot1x port
Explanation The RADIUS server tried to assign a VLAN to a client on a port,
but the VLAN name was not found in the VTP database.
Recommended Action This is an informational message only. No action is
required.
Error Message DOT1X-5-ERR_VLAN_RESERVED: The VLAN [dec] is a
reserved vlan and cannot be assigned for use on the Dot1x port
[char] Vlan
Explanation The specified VLAN is a reserved VLAN and cannot be assigned
for use on this port.
Recommended Action Update the configuration so that this VLAN is not used.
Error Message DOT1X-5-ERR_VLAN_RSPAN_CONFIGURED: VLAN [dec] is
configured as a Remote SPAN VLAN
Explanation Remote SPAN should not be enabled on a VLAN in which ports
are configured with 802.1X enabled.
Recommended Action Either disable remote SPAN configuration on the
VLAN, or disable 802.1X on all the ports in this VLAN.
Error Message DOT1X-5-INVALID_INPUT: Dot1x Interface parameter is
Invalid on interface [char]
Explanation The parameter that is specified for the 802.1X interface is not
valid (it could be outside the range of valid values).
Recommended Action Try again, using a valid value. See the CLI help to find
the valid 802.1X parameters.
Error Message DOT1X-5-INVALID_MAC: Invalid MAC address(drop
Explanation Authentication is allowed for an invalid source MAC address
because it is nonzero, it is not a broadcast, and it is not a multicast MAC
address.
Recommended Action Connect an 802.1X-supported host to the
802.1X-enabled interface.
Error Message DOT1X-5-NOT_DOT1X_CAPABLE: Dot1x disabled on
interface [char] because it is not an Ethernet interface
Explanation The user attempted to configure 802.1X on a non-supported
interface. 802.1X can be enabled on Ethernet module interfaces only.
Recommended Action Enable 802.1X authentication on Ethernet interfaces
only.
Error Message DOT1X-5-SECURITY_VIOLATION: Security violation on
interface [char] in single-host mode. Authorized MAC address was
[mac-addr]
Explanation That the port is configured in Single Host mode, so that any new
host that is added to this interface results in a security violation and the port
is shut down.
Recommended Action Ensure that the port is configured to use only one host.
Enter the shutdown command followed by the no shutdown command to
restart the port.
DTP Messages
This section contains the Dynamic Trunking Protocol (DTP) messages.
DTP-4
Error Message DTP-4-MEM_UNAVAIL:Memory not available to perform
the trunk negotiation action
Explanation The system is unable to negotiate trunks because of a lack of
memory.
Recommended Action Reduce other system activity to ease memory demands.
If necessary, upgrade to a larger memory configuration.
Error Message DTP-4-TMRERR:An internal timer error occurred when
trunking on interface [char]
Explanation Occasionally a timer used by the trunking protocol expires
unexpectedly. This problem is corrected internally.
Recommended Action This problem has no long-term ramifications. However,
if further trunking problems persist, you should reload the device.
Error Message DTP-4-UNKN_ERR:An unknown operational error occurred
Explanation The system is unable to negotiate trunks because an internal
operation generated an error that the protocol (DTP, in this case) did not
expect to handle.
Recommended Action Reload the device.
DTP-5
Error Message DTP-5-ILGLCFG:Illegal config(on
Explanation The two ports on the link are set to the ON mode, but one is set
to 802.1Q encapsulation, while the other is set to ISL encapsulation. When
both ports on a link are set to the ON mode, their encapsulation types must
match.
Recommended Action Configure both ports on the link to have the same
encapsulation type.
Error Message DTP-5-NONTRUNKPORTON:Port [dec]/[chars] has become
non-trunk
Explanation The interface [dec] / [chars] is nontrunked. [dec] / [chars] is the
module number/interface range.
Recommended Action This is an informational message only. No action is
required.
Error Message DTP-5-TRUNKPORTCHG:Port [dec]/[chars] has changed
from [chars] trunk to [chars] trunk
Explanation The encapsulation type of the trunk changed. [dec] is the module
number, the first [chars] is the interface number, the second [chars] is the
original encapsulation type, and the third [chars] is the new encapsulation
type.
Recommended Action This is an informational message only. No action is
required.
Error Message DTP-5-TRUNKPORTON:Port [dec]/[chars] has become
trunk
Explanation Interface [dec] / [chars] is trunked. [dec] / [chars] is the module
number/interface range.
Recommended Action This is an informational message only. No action is
required.
Error Message DTP-5-DOMAINMISMATCH: Unable to perform trunk
negotiation on port [char] because of VTP domain mismatch.
Explanation The two ports involved in trunk negotiation belong to different
VTP domains. Trunking is possible only when the ports involved belong to
the same VTP domain.
Recommended Action Reconfigure the switch to ensure that the two ports that
are involved in trunk negotiation belong to the same VTP domain.
EBM Messages
This section contains the Ethernet bridge management (EBM) messages.
EBM-3
Error Message C4K_EBM-3-CANTALLOCATEEBMPORT:No EbmPort memory to
allocate EbmPort for PimPort [char]
Explanation There is insufficient memory for information that is associated
with the specified port.
Recommended Action Install additional memory.
Error Message C4K_EBM-3-CANTALLOCATEIENODE:No interposition table
memory to add entry for addr %ea
Explanation There is insufficient memory for this internal data structure.
Recommended Action Install additional memory.
Error Message C4K_EBM-3-CANTALLOCATEIGMPGROUPENTRY:No igmp group
memory to add new group entry for addr [mac-addr]
Explanation This error occurs if you have created a large number of IGMP
groups and there is insufficient memory to support additional Internet Group
Management Protocol (IGMP) group entries.
Recommended Action Either install additional memory, or reduce the number
of IGMP groups.
Error Message C4K_EBM-3-CANTALLOCATEPORTHOSTENTRY:No port host
table memory to add entry for addr [mac-addr] / [mac-addr]
Explanation There is insufficient memory for this internal data structure.
Recommended Action Install additional memory.
Error Message C4K_EBM-3-CANTALLOCATEVLANGROUPENTRY:No vlan group
table memory to add entry for addr %ea
Explanation There is insufficient memory to support additional Layer 2 group
entries corresponding to IP multicast groups.
Recommended Action Install additional memory. If memory is unavailable,
turn off Cisco Group Management Protocol (CGMP)/Internet Group
Management Protocol (IGMP).
Error Message C4K_EBM-3-CANTALLOCATEVLANHOSTENTRY:No vlan host
table memory to add entry for addr %ea
Explanation There is insufficient memory to support additional host
addresses.
Recommended Action Install additional memory.
EBM-4
Error Message C4K_EBM-4-HOSTFLAPPING:Host [mac-addr] in vlan [dec]
is flapping between port [char] and port [char]
Explanation The specified host is detected as a source address on multiple
ports. Typically, a host is supposed to be learned on only one port. A spanning
tree loop is the most common cause of this condition. All traffic from the
specified host is temporarily dropped. After 15 seconds, forwarding is
reenabled. If the problem persists, the traffic from the problem host continues
to be dropped indefinitely.
Recommended Action Make sure that spanning tree is enabled to prevent
spanning tree loops. If you have spanning tree disabled, make sure that you
have no spanning tree loops in your network.
Error Message C4K_EBM-4-ZEROETHERADDR:Filtering Ethernet MAC
address of value zero from agent host table interface (port:
[char])
Explanation The switch learned about a host with the MAC address
00:00:00:00:00:00. This MAC address is not valid and was probably
generated by some non-IEEE 802.1D-compliant hardware or software in the
network.
The host sort algorithm does not sort hosts with MAC addresses that have all zeros (00:00:00:00:00:00), because a MAC address that has all zeros can not be listed in the learned host table. A request to show learned hosts, either by the show cam dynamic command or by an SNMP request, does not list a MAC address that has all zeros.
Recommended Action Track the source of the invalid MAC address because it
might cause other problems.
EC Messages
This section contains the EtherChannel (EC) messages.
EC-4
Error Message EC-4-NOMEM:Not enough memory available for [char]
Explanation The Port Aggregation Protocol or EtherChannel cannot obtain
the memory it needs.
Recommended Action This is an informational message only. No action is
required.
EC-5
Error Message EC-5-BUNDLE:Interface [char] joined port-channel
[char]
Explanation The interface has joined the bundle.
Recommended Action This is an informational message only. No action is
required.
Error Message EC-5-CANNOT_ALLOCATE_AGGREGATOR: Aggregator limit
reached
Explanation A new aggregator cannot be allocated in the group.
Recommended Action Change the port attributes of the ports in the group so
that they match and join the same aggregator.
Error Message EC-5-CANNOT_BUNDLE1:Port-channel [char] is
admin-down
Explanation The administrative state of the aggregation port channel is down.
The port remains in a standalone state until the state of the aggregation port
is up.
Recommended Action Ensure that all of the ports in the bundle have the same
configuration.
Error Message EC-5-CANNOT_BUNDLE2:[char] is not compatible with
[char] and will be suspended ([char])
Explanation The port has different port attributes from those of the port
channel (or the ports within the port channel).
Recommended Action Adjust the port attributes to match those of the port
channel.
Error Message EC-5-CANNOT_BUNDLE_LACP: [char] is not compatible
with aggregators in channel [dec] and cannot attach to them
([char])
Explanation This port has different port attributes than other ports within the
port channel.
Recommended Action Match the port attributes to that of the port channel.
Error Message EC-5-CANNOT_BUNDLE_QOS: Removed [char] from port
channel because a QoS policy cannot be supported across multiple
DFC cards.
Explanation The port that is specified in the error message cannot join a port
channel because the QoS policy that is attached to the port channel cannot
support multiple DFC cards.
Recommended Action Place the port in another port channel, or remove the
QoS policy from the port channel.
Error Message EC-5-COMPATIBLE: [char] is compatible with
port-channel members
Explanation The specified interface is not operational because its attributes
are different from the attributes of the port channel or the attributes of the
interfaces within the port channel. The switch detects that the attributes of the
specified port now match the port-channel attributes.
Recommended Action This is an informational message only. No action is
required.
Error Message EC-5-DONTBNDL: [char] suspended: incompatible
partner port with [char]
Explanation The configuration of the partner port is different from the
configuration of the other ports in the bundle. A port can join the bundle only
when the global configuration of the port and the configuration of the partner
port are the same as the other ports in the bundle.
Recommended Action Ensure that the configuration of the partner ports is the
same for all ports in the bundle.
Error Message EC-5-ERRPROT: Channel protocol mismatch for
interface [char] in group [dec]: the interface can not be added
to the channel group
Explanation The interface cannot be added to the channel group with the
specified mode.
Recommended Action Change the channel group or the mode for the interface.
Error Message EC-5-ERRPROT2: Command rejected: the interface
[char] is already part of a channel with a different type of
protocol enabled
Explanation The interface cannot be selected for the specified protocol
because it is already part of a channel with a different type of protocol
enabled.
Recommended Action Remove the interface from the channel group.
Error Message EC-5-ERRPROT3: Command rejected: the interface
[char] is already part of a channel
Explanation The interface cannot be unselected for the specified protocol
because it is already part of a channel.
Recommended Action Remove the interface from the channel group.
Error Message EC-5-L3DONTBNDL1:[char] suspended: PAgP not enabled
on the remote port.
Explanation PAgP is enabled on the Layer 3 interface, but the partner port
does not have PAgP enabled. In this mode, the port is put in a suspended state.
Recommended Action Enable PAgP on the remote side.
Error Message EC-5-L3DONTBNDL2: [char] suspended: LACP currently
not enabled on the remote port.
Explanation LACP is enabled on a Layer 3 interface, but the partner port does
not have LACP enabled. In this mode, the port is put in a suspended state.
Recommended Action Enable LACP on the remote side.
Error Message EC-5-NOLACP: Invalid EC mode
Explanation LACP is not included in the image. You cannot set EC mode to
active or passive.
Recommended Action Upgrade to an image with LACP, or set the mode to On.
Error Message EC-5-NOPAGP:Invalid EC mode
Explanation PAgP is not included in the image, so the EtherChannel mode
cannot be set to desirable/auto.
Recommended Action Obtain an image that includes PAgP, or set the mode to
ON.
Error Message EC-5-PORTDOWN: Shutting down [char] as its
port-channel is admin-down
Explanation The administrative state of the aggregate port is down, which
forces the administrative state of the port to also be down. The administrative
state of the port is controlled by the administrative state of its aggregate port.
Recommended Action Enter the no shutdown command on the aggregate port
to activate the aggregation port.
Error Message EC-5-STAYDOWN: no-shut not allowed on [char]. Module
[dec] not online
Explanation An interface with EtherChannel configuration cannot be
administratively up if its port channel is administratively down. Although this
interface has an EtherChannel configuration, it has no information about the
port channel. The no shutdown command is not supported.
Recommended Action Wait for the module to come online.
Error Message EC-5-UNBUNDLE:Interface [char] left the port-channel
[char]
Explanation The interface fell off the bundle.
Recommended Action This is an informational message only. No action is
required.
Error Message EC-5-UNSUITABLE:[char] will not join any
port-channel
Explanation The configurations for PortFast, VMPS, and Dest-SPAN are
incompatible with EtherChannel.
Recommended Action Unconfigure the three features so that the port can form
a bundle.
FLASH Messages
This section contains the Flash memory (C4K_FLASH) messages.
Error Message C4K_FLASH-4-COMPACTFLASHNOTFOUND: Cannot find
compact flash
Explanation You may see this message if the compact flash is not inserted
properly or if it is removed while the switch is trying to access the flash.
Recommended Action Reinsert the compact flash and retry the operation.
Error Message C4K_FLASH-4-COMPACTFLASHNOTREADY: Compact flash is
not ready
Explanation You may see this message if the compact flash is not inserted
properly or if it is removed while the switch is trying to access the flash.
Recommended Action Reinsert the compact flash and retry the operation.
GBICMAN Messages
This section contains the Gigabit Interface Converter (GBIC) Manager (GBICMAN) messages.
GBICMAN-3
Error Message C4K_GBICMAN-3-BADGBIC:Port [char]: Gbic's seeprom is
bad, try reinserting: vendor: [char], p/n: [char], s/n: [char]
Explanation The Gigabit Interface Converter (GBIC) serial EEPROM data is
corrupted.
Recommended Action Remove and reinsert the GBIC.
Error Message C4K_GBICMAN-3-GBICSEEPROMREADFAILED:Failed to read
gbic serial eeprom on port [char], try reinserting
Explanation The switch cannot identify the newly inserted GBIC or SFP.
Recommended Action Remove and reinsert the GBIC or SFP.
Error Message C4K_GBICMAN-3-S2WERROR: S2w bus error while looking
for changed gbics on port [char]: [char]
Explanation There was an internal communication error when the software
read the GBIC/SFP control data.
Recommended Action Contact your technical support representative.
HW Messages
This section contains the hardware (HW) message.
Error Message C4K_HW-3-S2WERROR:[char] [char] [dec] Error:
[object-info] Device Addr: [dec] Mem Addr: [object-info] Value:
[dec]
Explanation An unexpected error occurred when the switch accessed the
hardware device specified in the message.
Recommended Action Contact your technical support representative.
Error Message C4K_HW-3-X2IDENTIFICATIONFAILURE:Error while trying
to identify serdes type for [char] ( [dec] ) X2 module
Explanation There was an error when trying to identify the X2 module type.
Recommended Action Contact your technical support representative. You will
probably need to replace the supervisor engine.
Error Message C4K_HW-3-X2OUIREGREADFAILURE:Error while reading
Supervisor X2 OUI register Device Addr: [dec]
Explanation There was an unexpected error when accessing a hardware device
with the given device address.
Recommended Action Contact your technical support representative. You will
probably need to replace the supervisor engine.
Error Message C4K_HW-3-X2LOOPBACKFAILURE: Failed to put [char]
Xaui([dec]) [char] loopback
Explanation Software was unable to put the X2 in or out of loopback because
it was unable to determine the X2 type.
Recommended Action This is an informational message only. No action is
required.
HWACLMAN Messages
This section contains the hardware ACL Manager (HWACLMAN) messages.
Error Message C4K_HWACLMAN-4-ACLHWPROGERR:[input/output] [char] -
hardware TCAM limit, [char]
Explanation Some ACL-based features cannot be fully programmed into the
hardware. Packets that use these features complete processing in the software.
If the feature is a policy map, then QoS is completely disabled (on the specific
interface).
This message lists the impacted feature; further messages list the specific failure that occurred.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_HWACLMAN-4-ACLHWPROGERRREASON:[input/output]
[object-info] [char] - [char]
Explanation This message provides a specific failure that prevented
ACL-based features from being fully programmed into the hardware.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_HWACLMAN-4-CAMAUDIT: ACl/QOS CAM Health Check:
[input/output] [char] Index: [dec] [char] ( Cumulative Error
Count: [dec] )
Explanation The background system health monitor detected a potential
problem.
Recommended Action If this is a software error, the system has already
corrected itself automatically and no action is required. If this is a hardware
error, power cycle the switch.
Error Message C4K_HWACLMAN-4-CAMBLOCKMASKALLOCFAILED: CAM state
memory allocation failure in region [dec]
Explanation The software could not allocate memory to maintain a software
copy of the hardware classification TCAM masks that are used for ACL and
QoS functionality.
Recommended Action This condition should never occur. If you see this
message, copy it exactly and contact your technical support representative.
Error Message C4K_HWACLMAN-4-CLASSIFCAMPARITYERROR: Parity error
detected in [input/output] Classification CAM [char] Cell
[object-info] and corrected
Explanation The system detected and fixed a parity error in the hardware. If
you see this error repeatedly, there is a strong likelihood of a hardware fault
and the supervisor engine will need to be replaced.
Recommended Action The software fixes the parity error by rewriting the CAM
entries to the hardware. If the problem persists, contact your technical support
representative.
Error Message C4K_HWACLMAN-4-CLASSIFCAMREPLYPARITYERROR: Parity
error detected in lookup response from [input/output]
Classification CAM, Response Contents: [char]
Explanation The system detected a transient error in the classification TCAM
operation. If you see this message repeatedly, there is a strong likelihood of
a fault in the switching engine ASICs and the supervisor engine will need to
be replaced. Software will attempt to fix the parity error by rewriting the
TCAM entries to the hardware.
Recommended Action If the problem persists, contact your technical support
representative.
Error Message C4K_HWACLMAN-4-CLASSIFCAMREQPARITYERROR: Parity
error detected in lookup request to [input/output]
Classification CAM, Data [char] Address [char]
Explanation The system detected a transient error in the Classification TCAM
operation. If you see this error repeatedly, there is a strong likelihood of a
fault in the switching engine ASICs and the supervisor engine will need to be
replaced.
Recommended Action If the problem persists, contact your technical support
representative.
Error Message C4K_HWACLMAN-4-QOSFEATUREOUTOFSWRESOURCES: Out of
memory. [char] is inactive on port [char]
Explanation The software could not allocate memory to write the QoS related
configuration to the QoS TCAM hardware. The given QoS policy
configuration will not work on the given port until this is corrected.
Recommended Action This condition might occur under extreme ACL and/or
QoS configurations. Some workarounds to attempt are:
–
Try reducing the unwanted QoS and ACL configurations from ports and VLANs.
–
Try disabling and re-enabling QoS via the qos global configuration command.
If the problem persists, contact your technical support representative.
Error Message C4K_HWACLMAN-4-WARNINGSTRING:[char]
Explanation A nonspecific warning message was displayed.
Recommended Action See the message string [char] for more information.
HWL2MAN Messages
This section contains the Layer 2 Hardware Manager (HWL2MAN) message.
Error Message C4K_HWL2MAN-3-STMPARITYERROR: Parity error in
Spanning Tree Memory.
Explanation There is a parity error in the spanning tree memory, which can
indicate a transient hardware problem or a more permanent problem.
Recommended Action If you see this message too often, reboot the switch.
HWNETFLOWMAN Messages
This section contains the NetFlow Manager (HWNETFLOWMAN) messages.
HWNETFLOWMAN-3
Error Message C4K_HWNETFLOWMAN-3-NETFLOWSTOPPED:Too many netflow
parity errors encountered. It is very likely that this is bad
Netflow hardware. Stopping all netflow related activities.
Explanation The supervisor engine received too many parity errors from the
NetFlow Services Card. The supervisor engine stops all NetFlow-related
activities after issuing this message.
Recommended Action Contact your technical support representative.
HWNETFLOWMAN-4
Error Message C4K_HWNETFLOWMAN-4-HARDWAREUNRESPONSIVE: Netflow
Hardware too slow in responding to software requests
Explanation Software tried to access NetFlow hardware but there was no
response. Typically this would indicate that the NetFlow related hardware
may have gone bad.
Recommended Action Contact your technical support representative.
Error Message C4K_HWNETFLOWMAN-4-ERRORADDRS:Netflow Fatal Error
Info: Interrupt Status ( [dec] ), FDT1 Err Addr ( [dec] ), FDT2
Err Addr ( [dec] ), FLD Err Addr ( [dec] )
Explanation A fatal NetFlow error occurred. The message contains critical
information that can help you determine if the NetFlow hardware is
functioning properly or is bad.
Recommended Action Contact your technical support representative.
Error Message C4K_HWNETFLOWMAN-4-FATALERRORINTERRUPTSEEN: Netflow
Fatal Error interrupt seen
Explanation The NetFlow Services Card sent a fatal interrupt call to the
supervisor engine, which can crash the service card, the supervisor engine,
and the entire switch. This condition is extremely rare.
Recommended Action Contact your technical support representative.
Error Message C4K_HWNETFLOWMAN-4-FLOWSLOSTERR: Netflow stats lost
due to full hw flow table. [char] [dec] packets.
Explanation If the cache is full, then some flow statistics are lost. This
message informs users about the total collected flow statistics. If the counter
that tracks the lost statistics overflowed, an accurate count of total lost flows
is not available.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_HWNETFLOWMAN-4-NOFREEFLOWPOLICERS:[dec] flow
based policers are in use. All available flow policers are in
use. Can't allocate more number of flow policers
Explanation The maximum number of flow policers that can be allocated by
the system is 512. This message is displayed when the user tries to exceed that
limit.
Recommended Action Free existing flow policers before trying to define new
ones.
Error Message C4K_HWNETFLOWMAN-4-SWAGEDENTRYHWINVALIDATIONFAILED:
Invalidation failed for Hw flow (index: [object-info] )
associated with sw active-aged flow
Explanation Software tried to access NetFlow hardware, but there was no
response. Typically this would indicate that the NetFlow related hardware
may have gone bad.
Recommended Action Contact your technical support representative.
Error Message C4K_HWNETFLOWMAN-4-NONFATALPARITYERRORINTERRUPTSEEN
:Netflow Non Fatal Parity Error interrupt seen
Explanation The supervisor engine received a nonfatal parity error from the
NetFlow Services Card. The system should be able to recover from this
condition. If this condition reoccurs often, the NetFlow Services Card is
probably bad.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_HWNETFLOWMAN-4-SEDISABLEDAFTERDELAY: Se is
Disabled After a Small Delay
Explanation Software tried to access NetFlow hardware but there was no
response. Typically this would indicate that the NetFlow related hardware
may have gone bad. Access to the hardware was disabled.
Recommended Action This is an informational message only. No action is
required.
HWPORTMAN Messages
This section contains the hardware port management (HWPORTMAN) messages.
HWPORTMAN-4
Error Message C4K_HWPORTMAN-4-BLOCKEDTXQUEUE:Blocked transmit
queue HwTxQId[dec] on [char], count=[dec]
Explanation A transmit queue on a port is blocked for reasons other than
"paused." Bad hardware could cause this problem.
Recommended Action Contact your technical support representative.
Error Message C4K_HWPORTMAN-4-CHECKFORDUPLEXMISMATCH:[char]
Tx-Queue could be blocked due to duplex mismatch
Explanation The Tx queue on this port could be blocked due to a duplex
mismatch.
Recommended Action Fix the duplex mismatch to unblock the Tx queue.
Error Message C4K_HWPORTMAN-4-GIGAPORTRESETBYRXCONFIGWORD:[char]
has been reset by the received autonegotiation word.
Explanation The port stayed connected during switchover, but the device on
the other end of the link lost synchronization and restarted autonegotiation.
Recommended Action This is an informational message only. No action is
required.
HWPORTMAN-7
Error Message C4K_HWPORTMAN-7-FLOWCONTROLPACKET:Received invalid
flow control packet from [char] da [mac-addr] sa [mac-addr]
ethertype [hex] opcode [hex]
Explanation The supervisor engine forwarded a malformed flow control
packet to the software because one or both of the EtherType and flow
control/operation code is incorrect. For flow control packets, the expected
EtherType is 0x8808, and the expected operation code is 1 (xoff).
Recommended Action If the devices that are connected to the switch can
generate flow control and are configured for flow control, verify that the
devices can generate well-formed flow control packets with valid EtherType
and operation code fields.
IDBMAN Messages
This section contains the interface descriptor block (IDB) management (IDBMAN) messages.
IDBMAN-3
Error Message IDBMAN-3-AGGPORTMISMATCH:[char]:[char]([dec] /
[dec]) does match internal slot/port state [char]([dec] / [dec])
Explanation Due to an internal error the software is using an invalid aggregate
port.
Recommended Action This is an informational message only. No action is
required.
Error Message IDBMAN-3-DELETEDAGGPORT:[char]([dec] / [dec]) Group
[dec] has been deleted
Explanation Software is reusing a deleted interface for a new aggregate port.
Recommended Action This is an informational message only. No action is
required.
Error Message IDBMAN-3-INVALIDAGGPORTBANDWIDTH:[char]([dec] /
[dec]) has an invalid bandwidth value of [dec]
Explanation Software is using an invalid bandwidth for an aggregate port.
Recommended Action This is an informational message only. No action is
required.
Error Message IDBMAN-3-INVALIDPORT:[char]:trying to use invalid
port number [dec] (Max [dec])
Explanation Software is using an invalid port number.
Recommended Action This is an informational message only. No action is
required.
Error Message IDBMAN-3-INVALIDVLAN:[char]:trying to use invalid
Vlan [dec]
Explanation Software is using an invalid VLAN.
Recommended Action This is an informational message only. No action is
required.
Error Message IDBMAN-3-NOTANAGGPORT:[char]([dec] / [dec]) is not
an aggregate port
Explanation Software is using an interface that is not an aggregate port for
aggregate port operations.
Recommended Action This is an informational message only. No action is
required.
Error Message IDBMAN-3-PORTNOTINAGGPORT:[char]([dec] / [dec]) is
not present in Aggport [char]([dec] / [dec])
Explanation Software recognizes that the invalid port belongs to an aggregate
port.
Recommended Action This is an informational message only. No action is
required.
Error Message IDBMAN-3-VLANINUSE:[char]:Vlan [dec] is in use by
[char]
Explanation Each Layer 3 interface has a VLAN that is associated with it.
This message appears when some other Layer 3 interface is using the VLAN
associated with the interface.
Recommended Action This is an informational message only. No action is
required.
Error Message IDBMAN-3-VLANNOTSET:[char]:Vlan [dec] not set since
it already has Vlan [dec]
Explanation Due to a software error, an interface's VLAN was set to a
nonrequested value.
Recommended Action This is an informational message only. No action is
required.
IDBMAN-4
Error Message IDBMAN-4-ACTIVEPORTSINAGGPORT:[char]([dec] / [dec])
has [dec] active ports
Explanation Software has mistakenly removed an aggregate port with active
ports.
Recommended Action This is an informational message only. No action is
required.
IDBMAN-6
Error Message IDBMAN-6-VLANMAPPED:Vlan [dec] is mapped to [char]
Explanation The given VLAN was mapped to the specified interface.
Recommended Action This is an informational message only. No action is
required.
ILCPROTOCOLERROR Messages
This section contains the ILC Protocol (ILCPROTOCOLERROR)message.
Error Message C4K_ILC-3-PROTOCOLERROR: Service Module failed S2W
protocol, error [dec], state [dec]
Explanation The Serial 2-Wire (S2W) communication with an intelligent line
card deviated from the defined protocol.
Recommended Action This is an informational message only. No action is
required.
IOSACLMAN Messages
This section contains the Catalyst 4500 series Cisco IOS ACL management (IOSACLMAN) messages.
Error Message C4K_IOSACLMAN-4-ACLTYPEMISMATCH: Acl
RkiosSharedIos[char] was earlier attached as [char] Acl. Please
unconfigure all its uses before using it as a [char] Acl
Explanation This message displays if you attach a named ACL as one type,
delete the ACL, and configure an ACL of a different type with the same name.
For example, you configure a named IP ACL using the name DefaultAcl,
attach it to a router port, and then delete the ACL DefaultAcl by entering no
ip access-list extended DefaultAcl. You could configure a MAC ACL using
the same name. This message is displayed when you try to configure any
ACEs in the MAC ACL.
Recommended Action Remove all configurations where the ACL is used as an
IP ACL before configuring a MAC ACL with the same name.
Error Message C4K_IOSACLMAN-4-MOLACLALLOCFAILURE: Mol Acl
Allocation for [char] is failed
Explanation A new MOL ACL was created but there was insufficient memory
for a MOL ACL. The ACL was not applied.
Recommended Action Remove all configurations where the ACL is used as an
IP ACL before configuring a MAC ACL with the same name.
Error Message C4K_IOSACLMAN-4-MOLACLFEATUREALLOCFAILURE: Mol
AclFeature Allocation for Mol Acl: [dec] is failed
Explanation A new MOL ACL was created but there was insufficient memory
for a MOL ACL. The ACL was not applied.
Recommended Action Remove all configurations where the MOL ACL is used
as an IP ACL before configuring a MOL ACL with the same name.
Error Message C4K_IOSACLMAN-4-VLANMAPOUTOFMEMORY: Could not add an
entry to Vlan Map [char]. Out of memory
Explanation The system has insufficient memory to allocate a new entry for
this VLAN map.
Recommended Action Remove all configurations where the ACL is used as an
IP ACL before configuring a MAC ACL with the same name.
IOSDHCPSNOOPMAN Messages
This section contains the Catalyst 4500 series Cisco IOS DHCP Snooping Manager (IOSDHCPSNOOPMAN) messages.
Error Message C4K_IOSDHCPSNOOPMAN-4-CANNOTADDNEWIPLIST: Cannot add
new IP list for dhcp security on [char] and vlan [dec]
Explanation The switch attempted to add a new IP address to the list of
permitted IP addresses but failed. The new addresses are not permitted.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSDHCPSNOOPMAN-4-CANNOTENABLESECURITY: Cannot
enable dhcp security on [char] and vlan [dec]
Explanation The switch failed to enable IP source guard on the interface and
indicated VLAN. This error probably occurred because there might be too
many interface-VLAN pairs that have the feature enabled.
Recommended Action This is an informational message only. No action is
required.
IOSIGMPSNOOPMAN Messages
This section contains the Catalyst 4500 series Cisco IOS IGMP Snooping Manager (IOSIGMPSNOOPMAN)message.
Error Message C4K_IOSIGMPSNOOPMAN-3-NOSPACELEFT:No igmp group
memory to add new group entry
Explanation There is insufficient memory to support additional IGMP group
entries, which are added automatically when you run CGMP or IGMP.
Recommended Action Install additional memory, or reduce the number of
IGMP groups.
IOSINTF Messages
This section contains the Catalyst 4500 series Cisco IOS interface operation (IOSINTF) messages.
IOSINTF-4
Error Message C4K_IOSINTF-4-INTVLANALLOCFAIL:Failed to allocate
internal VLAN for interface [char]. The interface will remain
down.
Explanation When a routed port or port channel interface is enabled, it must
map to an internal VLAN in order to operate. If there are no internal VLANs
available when an interface is enabled, the interface remains down and this
message is logged.
Recommended Action An internal VLAN can be freed by disabling some other
routed port or port channel interface or by deleting a user-configured VLAN
in the 1006 to 4094 range. Once a VLAN is made available, the interface will
come up if it is disabled and reenabled.
Error Message C4K_IOSINTF-4-REFLEXIVEACLNOTSUPPORTED: Reflexive
Acls are not supported. Ignoring the [char] entry.
Explanation The reflexive ACLs are not supported. ACEs with the evaluate
and reflect keywords are ignored.
Recommended Action Do not configure ACEs with the evaluate or reflect
keywords.
IOSINTF-5
Error Message C4K_IOSINTF-5-GBICINSERTED: Slot= [dec] Port= [dec]:
GBIC has been inserted
Explanation An approved-vendor GBIC or SFP was inserted.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSINTF-5-GBICREMOVED: Slot= [dec] Port= [dec]:
GBIC has been removed
Explanation An approved-vendor GBIC or SFP was removed.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSINTF-5-NOPRIMARYVLANASSOCIATION:Packet
received on interface [char] in vlan [dec] without primary vlan
association. [mac-addr] will not be secured.
Explanation The switch received a packet on a secondary VLAN which does
not have a primary VLAN association. The switch will not secure a MAC
address in this situation.
Recommended Action Associate this secondary VLAN with a valid primary
VLAN.
Error Message C4K_IOSINTF-5-NOTXVLAN:Router Port [char] has no
internal vlan assigned to transmit packet
Explanation The specified Layer 3 interface does not have an assigned
internal VLAN because duplicate IP network assignments exist on different
Layer 3 interfaces.
Recommended Action Remove the duplicate IP network that is configured on
the interface. Assign the correct IP network, and enter the no shutdown
command on this interface.
Error Message C4K_IOSINTF-5-NOTXVLAN:Router Port [char] has no
internal vlan assigned to transmit packet
Explanation Occasionally during hot-swapping operations a previously
queued packet is transmitted after the module in that slot was removed.
Because the module no longer exists, the packets are dropped.
Recommended Action If the problem persists even without any hot-swapping
operations, contact your technical support representative.
Error Message C4K_IOSINTF-5-OUTPACLDISABLEDUETORACL: Output PACL
[char] is disabled on port [char]
Explanation If the port is configured for an SVI that has output RACL, then
the output PACL on the port is disabled. Output RACL and output PACL are
mutually exclusive, it is not possible to configure both simultaneously.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSINTF-5-OUTPACLDISABLEDUETOVACL: Output PACL
[char] is disabled on port [char]
Explanation If the port is configured for a VLAN that has output RACL, then
the output PACL on the port is disabled. Output RACL and output PACL are
mutually exclusive, it is not possible to configure both simultaneously.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSINTF-5-STALEPHYPORT: Dropping packets to be
transmitted out on port [char] ( Linecard in Slot [dec] may have
been removed )
Explanation During hot-swapping operations a previously queued packet may
be transmitted after a switching module is removed. This indicates such
packets are being dropped.
Recommended Action If this message appears without any hot swapping,
please contact your technical support representative.
Error Message C4K_IOSINTF-5-RJ45ACTIVE: Slot= [dec] Port= [dec]:
RJ45 connector has become active
Explanation A dual media port changed from using the SFP connector to
using the RJ-45 connector.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSINTF-5-RJ45INACTIVE: Slot= [dec] Port= [dec]:
RJ45 connector has become inactive
Explanation A dual media port changed from using the RJ-45 connector to the
SFP connector.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSINTF-5-TXL3PKTONPHYPORT:Transmitting L3
packet on a physical port [char] that is part of [char] ([dec]
packets). Make sure the physical port in the L3 port channel does
not have an ip addresses configured on it.
Explanation Layer 3 protocols operate at the logical, not the physical, port
level. Layer 3 protocol packets were sent on a physical port that is part of a
bundle. This condition occurs if there is a misconfiguration; a physical port
that is part of a Layer 3 port channel might have been assigned an IP address.
Recommended Action Verify that the physical interface in the Layer 3 port
channel does not have an IP address that is assigned to it.
Error Message C4K_IOSINTF-5-TXPKTDROPONETHERCHANNEL:Dropping
transmit packet out of interface [char]
Explanation A packet that should be transmitted out of a port channel was
dropped during transitions in the port channel membership. This condition
occurs when a packet is transmitted out of the aggregate port by higher layer
protocols, but the software cannot find the specific state information or when
physical ports transition into or out of the port channel membership.
Recommended Action If the problem persists, contact your technical support
representative.
IOSIPROUTEMAN Messages
This section contains the Catalyst 4500 series Cisco IOS IP Route Manager (IOSIPROUTEMAN) messages.
IOSIPROUTEMAN-3
Error Message C4K_IOSIPROUTEMAN-3-ADJMANNOMOREADJS:AdjMan:
hardware adjacency resources exhausted, performance may be
degraded.
Explanation The hardware adjacency resources have been exhausted. The
supervisor engine will forward packets to this adjacency in the software. This
action will likely represent a significant performance degradation.
Recommended Action Reduce the number of adjacencies that are loaded into
the routing table, and then clear the IP routing table.
Error Message C4K_IOSIPROUTEMAN-3-FIBCANTALLOCATEFIBADJ:IOS IP
Route Manager:No memory available to allocate FIB Adjacency for
[object-info]
Explanation The switch does not have sufficient memory to allocate space for
this adjacency; the supervisor engine will forward it in the software instead.
Recommended Action Reconfigure the network so that there are fewer hosts
that are directly adjacent to the Catalyst 4500 series switch, and then clear
and reload all of the routes (or reboot) so that the adjacent hosts that were
being sent to the software get reloaded.
Error Message C4K_IOSIPROUTEMAN-3-FIBCANTALLOCATEFIBENTRY:IOS IP
Route Manager:No memory available to allocate FIB Entry for
[ip-addr]
Explanation The switch has insufficient memory to allocate space for the
route that is associated with this network.
Recommended Action Contact your technical support representative because
memory leaks might exist.
Error Message C4K_IOSIPROUTEMAN-3-PBRDOESNOTSUPPORTQOS:Route-map
' [char] ' on interface ' [char] ' specifies Quality of Service
rewriting which is not supported via Policy-Based Routing on this
platform. Please use the Quality of Service feature instead. This
action on the specified route map will be ignored.
Explanation The switch does not support QoS services that are implemented
using PBR route maps. The PBR route map that is specified will be loaded,
but references to QoS services will be ignored.
Recommended Action Use the QoS policy maps and class maps to configure
this feature.
Error Message C4K_IOSIPROUTEMAN-3-VRFMANNOMOREVRFS: VrfMan: VPN
routing forwarding resources exhausted.
Explanation The VPN routing forwarding resources have been exhausted.
Recommended Action Reduce the total number of VPNs in the switch.
IOSL2MAN Messages
This section contains the Catalyst 4500 series Cisco IOS Layer 2 Manager (IOSL2MAN) message.
Error Message C4K_IOSL2MAN-3-VLANCREATIONERROR:Unable to create
new vlan [dec]
Explanation The switch does not have sufficient memory to allocate new
VLANs, so the new VLAN allocation failed.
Recommended Action Contact your technical support representative because
memory leaks might exist.
IOSMODPORTMAN Messages
This section contains the Catalyst 4500 series Cisco IOS module Port Manager (IOSMODPORTMAN) messages.
IOSMODPORTMAN-3
Error Message C4K_IOSMODPORTMAN-3-SSOMODULEREADYTIMEOUT: Internal
event: timed out after [dec] iterations waiting for the slot
[dec] to become ready.
Explanation There is an internal logic error. The state of this switching
module's ports will not be synchronized to the standby supervisor.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-3-SPANCONFIGOUTOFMEMORY:
RkiosSpanMan: Out of memory. Unable to process information for
RkiosSpanMan: ID. [dec]
Explanation The system ran out of memory.
Recommended Action Contact your technical support representative.
Error Message C4K_IOSMODPORTMAN-3-UNKNOWNPOWERSUPPLY: Unsupported
Power Supply has been inserted in slot [dec]
Explanation An unsupported or unknown power supply was inserted.
Recommended Action Replace the power supply with a supported power
supply.
IOSMODPORTMAN-4
Error Message C4K_IOSMODPORTMAN-4-CRITICALTEMP: Chassis
temperature is at or over critical threshold - current temp:
[dec]C, critical threshold: [dec]C
Explanation The chassis temperature is above a critical threshold. If some
action is not taken immediately to cool the chassis, the system shuts down to
prevent damage to the hardware.
Recommended Action Remove one or more modules to reduce the temperature
of the chassis, and check if the fan tray is functional.
Error Message C4K_IOSMODPORTMAN-4-CLOCKMODULEFAULTY: Clock module
switched to [dec] reason [char] for more info use the cmd:'show
environment status clock'
Explanation The clock module is faulty and may have to be replaced.
Recommended Action Replacing the module would require replacing the
switch chassis. Contact your technical support representative to confirm that
this is necessary.
Error Message C4K_IOSMODPORTMAN-4-INLINEPOWEROVERMAX:Inline power
exceeds max threshold:Module status changed to 'Pwr Max'
Explanation The measured PoE usage is higher than the module's physical
limit. This situation can be caused by misconfiguration or by one or more
unauthorized appliances drawing more PoE than allocated. In installations
with a 1400 W DC power supply, this warning can be a false positive. Refer
to bug id CSCef49715.
Recommended Action Make sure that the right amount of PoE is allocated to
each device. If the PoE allocation is correct, remove powered devices one at
a time and see if the power usage decreases as expected. (You can use the
show power detail command to see the PoE allocated to the module and the
PoE used.) If the power usage decreases sharply when a device is
disconnected, chances are that this device is using more PoE than allocated.
Avoiding using this device should solve your problem. If after disconnecting
all the devices on the module, the PoE usage is still high, and the system does
not use 1400 W DC power, contact you technical support representative.
If you see this message on a system using a 1400 W DC power supply, check the hardware revision of the switching module. If the module revision is earlier than the following, replace the switching module with a newer hardware revision:
WS-X4248-RJ45V 2.3
WS-X4248-RJ21V 2.3
WS-X4224-RJ45V 2.2
WS-X4548-GB-RJ45V 2.0
WS-X4524-GB-RJ45V 1.2
Error Message C4K_IOSMODPORTMAN-4-SSOMODULEOLDVERSION: Received
stale acknowledgement for the linecard in slot [dec]: expected
[dec], received [dec].
Explanation This is most probably the result of a linecard being rapidly
removed and reinserted.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-4-FANTRAYBAD:Fan tray has failed
Explanation The fan tray failed.
Recommended Action Replace the fan tray as soon as possible.
Error Message C4K_IOSMODPORTMAN-4-FANTRAYPARTIALFAILURE: One or
more fans in system fan tray have failed
Explanation This is a warning message indicating that one or more fans in the
system fan tray have failed.
Recommended Action Replace the fan tray as soon as possible.
Error Message C4K_IOSMODPORTMAN-4-FANTRAYREMOVED:Fan tray has been
removed
Explanation The fan tray was removed.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-4-FANTRAYGOOD:Fan tray is okay
Explanation The fan tray passed all tests and is operating normally.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-4-INLINEPOWERSUPPLYBAD: Inline
power from power supply [dec] has failed or been turned off
Explanation A PoE source from a power supply failed or was turned off. The
hardware cannot make a distinction between the two cases.
Recommended Action Fix or replace the power supply as soon as possible.
Error Message C4K_IOSMODPORTMAN-4-NFLABSENT: Netflow Services Card
absent or idprom invalid on [char] supervisor.
Explanation The recommended configuration for using the NetFlow Services
Card is to have it installed on both the standby and active supervisor engines.
Otherwise, during switchover, the system might lose its NetFlow capabilities.
Recommended Action Verify that the NetFlow Services Card is installed on
both supervisor engines.
Error Message C4K_IOSMODPORTMAN-4-NFLIDPROMINVALID: Netflow
Services Card has invalid idprom on [char] supervisor
Explanation The IDPROM on the NetFlow Services Card on the supervisor
engine indicated in the message is invalid.
Recommended Action Contact your technical support representative.
Error Message C4K_IOSMODPORTMAN-4-NFLMISMATCH: Netflow Services
Cards have mismatched [char]. ([dec] on [char] and [dec] on
[char]).
Explanation The IDPROM attributes of the NetFlow Services Cards installed
on the active and the standby supervisor engines do not match.
Recommended Action Verify that the NetFlow Services Card is correctly
installed on both supervisor engines.
Error Message C4K_IOSMODPORTMAN-4-PEMBAD: Power Entry Module has
failed
Explanation The external power supply source providing PoE power is bad.
Recommended Action Check the external power supply and replace it, if
necessary.
Error Message C4K_IOSMODPORTMAN-4-POWERSUPPLYBAD:Power Supply
[dec] has failed or been turned off
Explanation A power supply failed or was turned off. The hardware cannot
make a distinction between the two cases.
Recommended Action Replace the power supply as soon as possible.
Error Message C4K_IOSMODPORTMAN-4-POWERSUPPLYFANBAD:Fan of power
supply [dec] has failed
Explanation A power supply fan failed.
Recommended Action Replace the power supply as soon as possible.
Error Message C4K_IOSMODPORTMAN-4-POWERSUPPLYREMOVED:Power supply
[dec] has been removed
Explanation The power supply was removed.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-4-POWERSUPPLYOUTPUTDECREASED:
Power supply [dec] output has decreased
Explanation The power supply output decreased. This could be due to
switching it off, power failure, or some failure in the power supply.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-4-TEMPHIGH: Chassis temperature is
at or over threshold - CurrentTemp: [dec]C, Threshold: [dec]C
Explanation The chassis temperature is above the threshold. If the
temperature goes above a critical threshold, another message is logged and
the system shuts down to prevent damage to the hardware.
Recommended Action Inspect the chassis and environment to determine the
cause of the rise in temperature. Cool the system.
Error Message C4K_IOSMODPORTMAN-4-TEMPUNDERCRITICAL: Chassis
temperature is now under critical threshold but still very high
- current temp: [object-info] C, critical threshold:
[object-info] C
Explanation The chassis temperature is now below the critical threshold. The
chassis is still operating above the normal temperature.
Recommended Action Inspect the chassis to determine the cause of the
temperature problem. Cool the system.
IOSMODPORTMAN-6
Error Message C4K_IOSMODPORTMAN-6-CLOCKSWITCHOVER: Chassis Clock
Module switched to Clock: [dec]
Explanation This indicates that the clock module switched over to another
clock.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-6-INLINEPOWERSUPPLYGOOD: Inline
power from power supply [dec] is Ok
Explanation The PoE power supply just inserted in [dec] is functioning
normally.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-6-POWERSUPPLYOUTPUTINCREASED:
Power supply [dec] output has increased
Explanation The indicated power supply output increased.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-6-FANTRAYINSERTED:Fan tray has
been inserted
Explanation The fan tray was inserted.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-6-FANTRAYINSERTEDDETAILED: Fan
tray ([char] S/N: [char] Hw: [dec].[dec]) has been insertedT
Explanation The fan tray was inserted.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-6-INLINEPOWEROK:Inline power
within limits:Module status changed to 'Ok'
Explanation The measured PoE is now below the configured value and the
physical limit for the module.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-6-MODULEINSERTED: Module [dec] is
inserted
Explanation A module was inserted into slot [dec].
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-6-MODULEOFFLINE: Module [dec] is
offline
Explanation The specified module is offline.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-6-MODULEONLINE:Module [dec]
([char] S/N:[char] Hw:[dec].[dec]) is online
Explanation The specified module is online.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-6-MODULEREMOVED: Module [dec] is
removed
Explanation A module was removed from slot [dec].
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-6-PACKETMEMORYERRORPOWERCYCLE:Sup
ervisor power cycled due to packet memory errors
Explanation This supervisor was power cycled to get rid of SRAM errors
detected in the packet memory. It is expected that the transient SRAM errors
in packet memory are cleared by a power cycle of a supervisor.
Recommended Action Contact your technical support representative.
Error Message C4K_IOSMODPORTMAN-6-PACKETMEMORYERRORSOFTRESET:Supe
rvisor soft reset due to packet memory errors
Explanation This supervisor was reset because it encountered SRAM errors in
the packet memory. It was soft reset either because it does not have self power
cycle capability or the switch is operating in SSO mode.
Recommended Action Contact your technical support representative.
Error Message C4K_IOSMODPORTMAN-6-PEMGOOD: Power Entry Module has
been restored to working condition
Explanation The external power supply source providing PoE is working
correctly.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-6-POWERSUPPLYFANGOOD:Fan of power
supply [dec] is okay
Explanation A failed power supply was fixed.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-6-POWERSUPPLYGOOD:Power supply
[dec] is okay
Explanation A failed power supply was fixed.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-6-POWERSUPPLYINSERTED:Power
supply [dec] has been inserted
Explanation The specified power supply was inserted.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-6-POWERSUPPLYINSERTEDDETAILED:
Power supply [dec] ([char] S/N: [char] Hw: [dec].[dec]) has been
inserted
Explanation A power supply was inserted.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSMODPORTMAN-6-TEMPOK: Chassis temperature is
now ok - CurrentTemp: [dec]C, Threshold: [dec]C
Explanation The chassis temperature is now normal.
Recommended Action This is an informational message only. No action is
required.
C4K_IOSREDUNDANCYMAN Messages
This section contains the Catalyst 4500 series Cisco IOS module Redundancy Manager (IOSREDUNDANCYMAN) messages.
Error Message C4K_IOSREDUNDANCYMAN-3-BUFFERALLOCATIONFAILED:Rkios
CheckpointMan:Buffer allocation error (client:[char],
error:[dec])
Explanation There was an internal error when allocating resources for the
checkpoint facility.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSREDUNDANCYMAN-3-CHECKPOINTMESSAGESENDFAILURE
:RkiosCheckpointMan:Message send failure (client:[char])
Explanation There was an internal error when allocating resources for the
checkpoint facility.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSREDUNDANCYMAN-3-NEWCHECKPOINTCLIENTFAILED:Rk
iosCheckpointMan:Error adding new client (client:[char],
error:[dec])
Explanation There was an internal error when allocating resources for the
checkpoint facility.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IOSREDUNDANCYMAN-3-NEWCLIENTREGISTRATIONFAILED:
RkiosRedundancyMan:Error adding new client (client:[char],
error:[dec])
Explanation There was an internal error when allocating resources for the
redundancy facility.
Recommended Action This is an informational message only. No action is
required.
IOSSYS Message
This section contains the Catalyst 4500 series IOS system (IOSSYS) messages.
IOSSYS-3
Error Message C4K_IOSSYS-3-BLANKSTARTUPCONFIG: Blank or invalid
startup-config
Explanation An empty or invalid startup-config file was found in the
NVRAM. The switch is booting up with default settings.
Recommended Action Configure the switch and save the configuration to
NVRAM as the startup file for the next reboot. If the problem persists, contact
your technical support representative.
Error Message C4K_IOSSYS-3-SAVEPOSTRESULTFAILED: Failed to save
POST results to [char]. [char].
Explanation The system cannot save the POST results to bootflash because
the bootflash memory might be full.
Recommended Action Check if the bootflash memory is full. If the bootflash
memory is full, delete the old POST results by entering the delete \force
post* and the squeeze bootflash: commands.
IOSSYS-4
Error Message C4K_IOSSYS-4-BLANKPRIVATECONFIG: Blank or invalid
private-config
Explanation An invalid private-config is found in the NVRAM, or the
private-config was missing.
Recommended Action If this message comes up after a software upgrade, try
saving the configuration again and reboot the switch. If the message goes
away in the next boot, then it can be ignored. If this message displays each
time that the switch is rebooted, contact your technical support
representative.
IOSSYS-7
Error Message C4K_IOSSYS-7-INVALIDVALUE: [char] Type [dec] not
handled returning a default of 0
Explanation This message is used by developers only and should not occur
during customer operation.
Recommended Action Contact your technical support representative.
Error Message C4K_IOSSYS-7-SETENVERR: Failed to set environment
variable: [char].
Explanation The system cannot write the specified environment variable
because the bootflash memory or NVRAM has insufficient memory.
Recommended Action Clear the unnecessary environment variables by
entering the clear platform environment variable unsupported command,
and then reboot your switch.
IOSSYSMAN Messages
This section contains the Catalyst 4500 series Cisco IOS System Manager (IOSSYSMAN) messages.
IOSSYSMAN-0
Error Message C4K_IOSSYSMAN-0-FATALERRORCRASH:Forced crash due to:
[char]
Explanation The system is unusable due to software or hardware failures.
Recommended Action Analyze the memory dump, if any, and determine the
cause of the failure, or contact your technical support representative.
IOSSYSMAN-3
Error Message C4K_IOSSYSMAN-3-ENVVARNAMETOOLONG:Name of
environment variable
Explanation The environment variable name is too long.
Recommended Action Enter the unset command to shorten the name.
Error Message C4K_IOSSYSMAN-3-OUTOFPACKETHEADERS:Cannot allocate
buffer for a packet header
Explanation The system cannot allocate a buffer for the packet header.
Recommended Action Contact your technical support representative, and
provide the configuration information for the switch.
IOSSYSMAN-4
Error Message C4K_IOSSYSMAN-4-ENVVARTOOLONG: Value of env.
variable [char] is too long
Explanation The software writes certain configuration values to the NVRAM.
The variable name is too long (greater than 4096 bytes) for the available
storage space.
Recommended Action Boot the system into ROMMON mode. At the
ROMMON prompt, enter the unset command to change the environment
variable name to a shorter name.
Error Message C4K_IOSSYSMAN-4-NOSPACEFORENVVAR: Env. variable
[char] cannot be set: no space
Explanation The software writes certain configuration values to the NVRAM.
The switch has insufficient memory to write an environment variable.
Recommended Action Boot the system into ROMMON mode. At the
ROMMON prompt, enter the unset command to remove the unused
environment variables to reclaim the space.
IPROUTEMAN Messages
This section contains the Catalyst 4500 series Cisco IOS IP Routing Manager (IPROUTEMAN) messages.
IPROUTEMAN-3
Error Message C4K_IPROUTEMAN-3-CANTALLOCATEIPETHERADDRENTRY:IP
Route Manager:No memory to add Router Port MAC Address, numInUse:
[dec]
Explanation Each router port in the system can listen to secondary MAC
addresses as the "router's MAC address," which is a process that is useful for
protocols like Hot Standby Routing Protocol (HSRP). The system does not
have sufficient memory to hold secondary MAC addresses.
Recommended Action Boot the switch into ROMMON mode. At the
ROMMON prompt, enter the unset command to remove the unused
environment variables to reclaim the space.
Error Message C4K_IPROUTEMAN-3-FIBADJMANDUPLICATEADJ:FIB
Entry:Tried to create a duplicate adj for key [object-info]
Explanation A request was made to add a duplicate adjacency to the
Forwarding Information Base (FIB) adjacency database.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IPROUTEMAN-3-FIBADJMANINUSEDELETION:FIB
Adjacency Manager:Attempted to delete FIB Adjacency Id [dec]
which is in use
Explanation A request was made to delete an adjacency from the Forwarding
Information Base (FIB) database while that adjacency was still referenced by
a routing table entry.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IPROUTEMAN-3-FIBADJMANNONEXISTENTDELETION:FIB
Adjacency Manager:Attempted to delete FIB Adjacency Id [dec]
which does not exist
Explanation A request was made to delete an adjacency from a platform
Forwarding Information Base (FIB) that does not exist.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IPROUTEMAN-3-FIBDUPLICATEENTRY:FIB:Attempt to
create a duplicate FIB Entry for [ip-addr]
Explanation A request to add a duplicate routing table entry to the Forwarding
Information Base (FIB) database was detected.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IPROUTEMAN-3-FIBENTRYNOSUCHADJTODELETE:FIB
Entry:Couldn't delete adj [ip-addr] from FIB Entry [ip-addr], no
such adj.
Explanation A request was made to delete an adjacency from a routing table
entry in the platform Forwarding Information Base (FIB), and the adjacency
was not found.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IPROUTEMAN-3-FIBENTRYTOOMANYADJ:FIBEntry: FIB
Entry: Too many adjacencies on FIB Entry for [ip-addr], tried to
add adj [ip-addr]
Explanation A request was made to add another adjacency to a routing table
entry in the platform Forwarding Information Base (FIB) when that entry was
already at the maximum allowed value.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IPROUTEMAN-3-FIBNONEXISTENTDELETION:FIB:Attempt
ed to delete FIB Entry Id [dec] which does not exist
Explanation A request was made to delete a nonexistent routing table entry
from the platform Forwarding Information Base (FIB).
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IPROUTEMAN-3-NOMOREK2FIBADJS:K2FibUnicast:no
more K2FibAdjs available, using punt adj instead for [ip-addr]
route.
Explanation The hardware resources for adjacencies have been exhausted;
switching will take place in the software instead. The switch performance
might be degraded.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IPROUTEMAN-3-VRFMANDUPLICATEVRF: Tried to create
a duplicate VRF for key [object-info]
Explanation A request was made to add a duplicate VRF.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_IPROUTEMAN-3-VRFMANNONEXISTENTDELETION:
Attempted to delete VRF with key [object-info] which does not
exist
Explanation A request was made to delete a VRF that does not exist.
Recommended Action This is an informational message only. No action is
required.
IPROUTEMAN-4
Error Message C4K_IPROUTEMAN-4-CANTALLOCATEFIBENTRY: FIB: No
memory available to allocate FIB Entry
Explanation The switch has insufficient memory to allocate space for the
route that is associated with this network.
Recommended Action Install additional memory.
Error Message C4K_IPROUTEMAN-4-VRFMANCANTALLOCATEVRF: No memory
available to allocate VRF for key [object-info]
Explanation The switch has insufficient memory to allocate space for VRF.
Recommended Action Install additional memory.
L2MAN
This section contains the L2MAN messages.
Error Message C4K_L2MAN-5-ROUTERMACADDRESSRXASSOURCE:Packet
received with my own MAC address ( [mac-addr] ) as source on
port [char] in vlan [dec]
Explanation A packet was received with the switch's MAC address as the
source address. This MAC was not learned as a valid source address, which
suggests that there is a configuration problem. This message is rate-limited
and is displayed only for the first such packet received on any interface or
VLAN. Subsequent messages will display cumulative count of all such
packets received in given interval on all interfaces in any vlan.
Recommended Action Check the switch configuration file to determine the
source of these packets on the specified port and take corrective action to fix
them at the source. This usually signifies a loop in your configuration.
Error Message C4K_L2MAN-6-INVALIDSOURCEADDRESSPACKET:Packet
received with invalid source MAC address ( [mac-addr] ) on port
[char] in vlan [dec]
Explanation A packet was received with an all zero or a multicast source
address. The packet is treated as invalid and no learning is done. Excessive
flow of such packets can waste CPU cycles. This message is rate-limited and
is displayed only for the first such packet received on any interface or VLAN.
Subsequent messages will display cumulative count of all such packets
received in given interval on all interfaces.
Recommended Action Check the switch configuration file to find the source of
these packets on the specified port and take corrective action to fix them at
the source end. You can also enable port security on that interface to
shutdown the port if the incoming rate of packets with invalid source mac
address is too high by issuing the switchport port-security limit rate
invalid-source-mac <rate> command.
L3HWFORWARDING Messages
This section contains the Layer 3 hardware forwarding (L3HWFORWARDING) messages.
L3HWFORWADING-2
Error Message C4K_L3HWFORWARDING-2-FWDCAMFULL:L3 routing table is
full. Switching to software forwarding.
Explanation The hardware routing table is full; forwarding takes place in the
software instead. The switch performance might be degraded.
Recommended Action Reduce the size of the routing table. Enter the ip cef
command to return to hardware forwarding.
L3HWFORWADING-3
Error Message C4K_L3HWFORWARDING-3-FTECONSISTENCYCHECKFAILED:
FwdTableEntry Consistency Check Failed: index [dec]
Explanation There was a consistency check failure. If this error occurs
frequently, it could indicate faulty hardware.
Recommended Action If the problem persists, contact your technical support
representative.
Error Message C4K_L3HWFORWARDING-3-FWDCAMCONSISTENCYCHECKFAILED:
FwdCam Consistency Check Failed: index [dec]
Explanation There is a FwdCam consistency check failure. If this error occurs
frequently, it could indicate faulty hardware.
Recommended Action If the problem persists, contact your technical support
representative.
Error Message C4K_L3HWFORWARDING-3-FWDMEMPARITYERROR: Parity error
in Forwarding Memory
Explanation There is a parity error in forwarding memory. This error message
could indicate a transient hardware problem or a more permanent problem.
Recommended Action If you see this message multiple times, reboot the
switch.
Error Message C4K_L3HWFORWARDING-3-MASKTABLECONSISTENCYCHECKFAILE
D: MaskTable Consistency Check Failed: block [dec]
Explanation There was a mask table consistency check failure. If this error
occurs frequently, it could indicate faulty hardware.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_L3HWFORWARDING-3-MASKTABLEREGIONCONSISTENCYCHEC
KFAILED: MaskTable Consistency Check Failed: region
[object-info]
Explanation There is a consistency check failure in the mask table. The error
is located in the region that is specified by [object-info].
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_L3HWFORWARDING-3-NOMOREK2FIBADJS:No hardware
adjacency resource available for route [ip-addr]
Explanation The hardware adjacency table has insufficient memory to
allocate the adjacency set for this route. Forwarding will take place in the
software instead.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_L3HWFORWARDING-3-PBRBLOCKFAILEDTOADDFLATACE:K2F
ibPbrBlock:failed to add FlatAce [object-info] to block [dec]
Explanation The policy-routing data structures are corrupted. This memory
corruption will probably crash the switch soon.
Recommended Action Contact your technical support representative.
Error Message C4K_L3HWFORWARDING-3-PBRBLOCKFAILEDTODELETEFLATACE:
K2FibPbrBlock: failed to remove FlatAce [object-info] from
block [dec]
Explanation The policy-routing data structures are corrupted. This memory
corruption will probably crash the switch soon.
Recommended Action Contact your technical support representative.
Error Message C4K_L3HWFORWARDING-3-PBRFLATTENINGFAILED: Software
resource exhaustion trying to load route-map for interface
[char] ( [dec] ), elapsed time is [object-info] us
Explanation The switch has insufficient memory to process the access list for
a route map.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_L3HWFORWARDING-3-PBRNOPBRCAMLEFT: K2FibPbr:
attempted addition of [dec] blocks to PBR cam region failed,
only managed to get [dec] for FRM [char]
Explanation There is insufficient memory to program a new route map.
Recommended Action Remove unused portions of the configuration to free the
needed memory.
Error Message C4K_L3HWFORWARDING-3-PBRPUNTINGPORT: Policy routing
exceeded maximum TCAM usage, all IP unicast traffic on interface
[char] will be switched in software.
Explanation The hardware policy-based routing forwarding engine has
insufficient resources to handle the route map for the specified interface. All
unicast IP traffic for that interface will be switched in the software instead.
Recommended Action This is an informational message only. No action is
required.
L3HWFORWADING-4
Error Message C4K_L3HWFORWARDING-4-FLOWCACHEOUTOFSPACEFORFLOWCACH
EENTRY: K2FibFlowCache: insufficient space to store flow of type
[object-info] with label [packet-info]
Explanation The software cannot load a flow cache entry into the hardware
due to insufficient memory.
Recommended Action This is an informational message only. No action is
required.
L3HWFORWADING-6
Error Message C4K_L3HWFORWARDING-6-NOLONGERPBRPUNTINGPORT:
Sufficient Policy Routing TCAM space has been found to handle
PBR for interface [char] in hardware, no longer punting to
software.
Explanation The hardware policy-based routing forwarding engine now has
sufficient resources to handle the route map for the specified interface and can
now do hardware forwarding of unicast IP traffic.
Recommended Action This is an informational message only. No action is
required.
LINECARDMGMTPROTOCOL Messages
This section contains the module management protocol (LINECARDMGMTPROTOCOL) messages.
Error Message C4K_LINECARDMGMTPROTOCOL-4-INITIALTIMEOUTWARNING:
[char] - management request timed out.
Explanation There are communication problems with the module ASIC that
fans out a single gigabit port to front-panel ports. A few messages are within
tolerance levels.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_LINECARDMGMTPROTOCOL-4-ONGOINGTIMEOUTWARNING:
[char] - consecutive management requests timed out.
Explanation There are persistent communication problems with the module
ASIC that fans out a single gigabit port to front-panel ports.
Recommended Action Reinsert the module.
PKTPROCESSING Messages
This section contains the packet processing (PKTPROCESSING) messages.
PKTPROCESSING-3
Error Message C4K_PKTPROCESSING-3-INVALIDVLAN:Packet received on
invalid Vlan from hardware. PortId [dec] [l2-header] Vlan [dec]
TagType [object-info]
Explanation The hardware sent a packet to the CPU, but the receiving VLAN
was incorrect. There is probably a hardware problem.
Recommended Action Contact your technical support representative.
Error Message C4K_PKTPROCESSING-3-OUTOFPACKETINFOTODRIVER: \"Ran
out of memory to send packet information to the driver that
enqueues packets to hardware\"
Explanation Transmit packets are probably stuck in a queue, and some of the
packets have been sent to multiple destinations. This event wastes memory,
so new packet information cannot be allocated.
Recommended Action Contact your technical support representative.
Error Message C4K_PKTPROCESSING-3-OUTOFPACKETSTODRIVER: \"Ran out
of memory to send packets to the driver that enqueues packets to
hardware\"
Explanation Transmit packets are probably stuck in a queue, so new packets
cannot be queued.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_PKTPROCESSING-3-REPLICATEDINVALIDVLAN:
Replicated packet received on Vlan 0, CRC32 is valid. PortId
[dec] [l2-header] Vlan [dec] TagType [object-info] count
[object-info]
Explanation A replicated packet was received on VLAN 0. The CRC32 packet
is correct. If the count is high, there may be a hardware problem.
Recommended Action Contact your technical support representative.
Error Message C4K_PKTPROCESSING-3-UNEXPECTEDOUTPUTACLHIT:Packet
hit output ACL but sent to CPU as a result of hardware input Acl
processing [l2-header] Port char] Vlan [dec]
Explanation A n inconsistent hardware state might exist. A packet was sent to
the CPU due to input ACL processing by the hardware. The packet
unexpectedly encountered output ACL processing.
Recommended Action Contact your technical support representative.
Error Message C4K_PKTPROCESSING-3-UNRECOGNIZEDEVENT:Packet
received for an unimplemented event. CPU Subport [dec] TxQId
[dec] PDD {[dec], [dec]}
Explanation The hardware sent a packet to the CPU, but the software did not
recognize the event that triggered the packet to be sent.
Recommended Action This is an informational message only. No action is
required.
PKTPROCESSING-4
Error Message C4K_PKTPROCESSING-4-ERRORPACKET:[char]
Explanation The software is unable to process a packet; the packets have been
forwarded to the CPU instead and the packet will be dropped.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_PKTPROCESSING-4-INVALIDACLACTION:Unable to
determine the ACL action to take because we ran out of memory.
Address: src [mac-addr] dst [mac-addr]
Explanation There is insufficient memory to create a list of actions to perform
on the packet. As a result, the packet was dropped.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_PKTPROCESSING-4-INVALIDACLACTIONFORSPANPORT:
Unable to determine the ACL action to take because we ran out of
memory. Address: src [mac-addr] dst [mac-addr]
Explanation There is insufficient memory to create a list of actions to perform
on the packet. As a result, the packet was dropped.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_PKTPROCESSING-4-UNKNOWNBRIDGEORROUTE:Unable to
determine whether to route or bridge replicated
software-processed packet with source address [mac-addr] and
destination address [mac-addr]
Explanation When a replicated packet is sent to the software by an output
ACL, the hardware does not indicate whether the packet needs to be bridged
or routed.
When resources are exhausted or when the ACLs that are programmed in the hardware cannot handle processing directly (such as ACLs matching TCP flags), Supervisor Engine III sends the packets to the software for processing. If the software cannot determine whether to bridge or route, the packet might be dropped. This drop indicates that the packet was directed to a Hot Standby Routing Protocol (HSRP) router group MAC address.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_PKTPROCESSING-4-UNKNOWNSOURCELOCATIONFORBRIDGE:
Unable to determine source host location of replicated
software-processed packet with source address [mac-addr] and
destination address [mac-addr]
Explanation When a replicated packet is sent by an output ACL to the
software for processing, the hardware does not indicate the ingress port or
VLAN ID.
When resources are exhausted or when the ACLs that are programmed in the hardware cannot handle processing directly (such as ACLs matching TCP flags), Supervisor Engine III sends the packets to the software for processing. Without the ingress port identifier, the supervisor engine might forward the packet back out the port on which it was received, possibly creating network loops or other problems. If the switch is unable to recognize the ingress port from other information, the packet is dropped.
Recommended Action This is an informational message only. No action is
required.
PKTPROCESSING-5
Error Message C4K_PKTPROCESSING-5-NOTAPPLYINGACL:Not applying
[input/output] Acl for packet [packet-info]
Explanation The software is unable to determine the correct ACL entry that is
indicated by the hardware. The hardware-provided index of the ACL
content-addressable memory (CAM) indicates that the software needs to take
the actions for the entry at that index. If the packet was queued in the
hardware before the software could process it, the index is out of date.
Recommended Action This is an informational message only. No action is
required.
PKTPROCESSING-7
Error Message C4K_PKTPROCESSING-7-ADJLOOKUPFAILED:Draining the
backed up packets in CPU queue when we cleaned up FIB
adjacencies. Last drained packet's source address [ip-addr] and
destination address [ip-addr]
Explanation This event can occur when the software processes the routed
packets and the router port is shut down. The software can automatically
repair adjacencies, but there was at least one packet in the queue that was lost.
Recommended Action This is an informational message only. No action is
required.
Pluggable Messages
This section contains the SFP management (C4K_PLUGGABLEMAN) messages.
Error Message C4K_PLUGGABLEMAN-3-BADX2: Port [char]: X2's seeprom
is bad, try reinserting: vendor: [char], p/n: [char], s/n: [char]
Explanation The X2 SEEPROM data may be corrupted.
Recommended Action Reinsert the X2 module.
Error Message C4K_PLUGGABLEMAN-3-ETHHOLEERROR:
EthHolePluggableMan reviewing port [char], EthHoleError [char]
Explanation The software is unable to read the SEEPROM on this X2.
Recommended Action Contact your technical support representative. You will
probably have to replace the X2 module.
Error Message C4K_PLUGGABLEMAN-3-X2SEEPROMREADFAILED: Failed to
read x2 serial eeprom on port [char], try reinserting
Explanation The system could not identify the newly inserted X2.
Recommended Action Re-insert the X2 module.
PM Messages
This section contains the Port Manager (PM) messages.
PM-2
Error Message PM-2-LOW_SP_MEM: Switch process available memory is
less than [dec] bytes
Explanation The switch has insufficient memory for processing. Too many
Layer 2 VLANs might have been configured in the system.
Recommended Action Remove Layer 2 VLANs or other features from the
system to reduce memory usage.
Error Message PM-2-NOMEM:Not enough memory available for [char]
Explanation The Port Manager subsystem cannot obtain sufficient memory
for the specified PM operation. [char] is the PM operation ID.
Error Message PM-2-VLAN_ADD:Failed to add VLAN [dec] - [char].
Explanation The VLAN was not added to VTP, because of the reason stated
in the text string.
Recommended Action This is an informational message only. No action is
required.
PM-3
Error Message PM-3-ERR_INCOMP_PORT: [dec]/[dec] is set to inactive
because [dec]/[dec] is a [char] port
Explanation The private host port cannot be configured with the trunk, private,
promiscuous, and SPAN destination port on the same coil.
Recommended Action Try to configure the incompatible ports on different
coils.
Error Message PM-3-INTERNALERROR:Port Manager Internal Software
Error ([char]:[char]:[dec]:[char])
Explanation The access VLAN on the VMPS server is set to the same VLAN
as a voice VLAN on the port. The access VLAN assignment on the VMPS
server should be different from the voice VLAN.
Recommended Action Reset the VLAN assignments to remove the conflict.
PM-4
Error Message PM-4-BAD_APP_ID:an invalid application id [dec] was
detected
Explanation The Port Manager detected a request with an invalid application
ID, where [dec] is the application ID.
Recommended Action Reset the VLAN assignments to remove the conflict.
Error Message PM-4-BAD_APP_REQ:an invalid [char] request by the
`[char]' application was detected
Explanation The Port Manager detected an invalid request. The first [char] is
the invalid request, and the second [char] is the application making the
request.
Recommended Action Reset the VLAN assignments to remove the conflict.
Error Message PM-4-BAD_CARD_COOKIE:an invalid card cookie was
detected
Explanation The Port Manager detected an invalid request.
Recommended Action Reset the VLAN assignments to remove the conflict.
Error Message PM-4-BAD_CARD_SLOT:an invalid card slot [dec] was
detected
Explanation The Port Manager detected an invalid request on slot number
[dec].
Recommended Action Reset the VLAN assignments to remove the conflict.
Error Message PM-4-BAD_COOKIE:[char] was detected
Explanation The Port Manager detected an invalid request.
Recommended Action Reset the VLAN assignments to remove the conflict.
Error Message PM-4-BAD_HA_ENTRY_EVENT: Invalid Host access entry
event ([dec]) is received
Explanation The entry event is not an add, delete, or update event (the only
supported types).
Recommended Action Enter the show tech-support privileged EXEC
command to gather data that might provide information about the error. If you
cannot determine the cause of the error from the error message or from the
show tech-support command display, copy the error message exactly as it
appears on the console or in the system log, contact your technical support
representative, and provide the representative with the gathered information.
Error Message PM-4-BAD_PORT_COOKIE:an invalid port cookie was
detected
Explanation The Port Manager detected an invalid request.
Recommended Action Enter the show tech-support privileged EXEC
command to gather data that might provide information about the error. If you
cannot determine the cause of the error from the error message or from the
show tech-support command display, copy the error message exactly as it
appears on the console or in the system log, contact your technical support
representative, and provide the representative with the gathered information.
Error Message PM-4-BAD_PORT_NUMBER:an invalid port number [dec]
was detected
Explanation The Port Manager detected an invalid request on interface
number [dec].
Recommended Action Enter the show tech-support privileged EXEC
command to gather data that might provide information about the error. If you
cannot determine the cause of the error from the error message or from the
show tech-support command display, copy the error message exactly as it
appears on the console or in the system log, contact your technical support
representative, and provide the representative with the gathered information.
Error Message PM-4-BAD_VLAN_COOKIE:an invalid vlan cookie was
detected
Explanation The Port Manager detected an invalid request.
Recommended Action Try a different VLAN on the device.
Error Message PM-4-BAD_VLAN_ID:an invalid vlan id [dec] was
detected
Explanation The Port Manager detected an invalid request. The invalid VLAN
ID is [dec].
Recommended Action Try a different VLAN on the device.
Error Message PM-4-ERR_DISABLE:[char] error detected on [char]
Explanation The Port Manager will put the interface in the errdisable state
when it detects a misconfiguration or misbehavior. After the configured retry
time (5 minutes by default), the system will attempt to recover the interface.
Recommended Action This is an informational message only. No action is
required.
Error Message PM-4-ERR_RECOVER:Attempting to recover from [char]
err-disable state on [char]
Explanation The system is attempting to bring the interface back from the
errdisable state.
Recommended Action This is an informational message only. No action is
required.
Error Message PM-4-EXT_VLAN_INUSE: VLAN [dec] currently in use by
[char]
Explanation The Port Manager failed to allocate the VLAN for external use
because the VLAN is currently occupied by another feature.
Recommended Action Reconfigure the feature to use another internal VLAN,
or request another available VLAN.
Error Message PM-4-EXT_VLAN_NOTAVAIL: VLAN [dec] not available in
Port Manager
Explanation The Port Manager failed to allocate the requested VLAN. The
VLAN might be used as an internal VLAN by other features.
Recommended Action Reconfigure the feature to use another internal VLAN,
or request another available VLAN.
Error Message PM-4-INACTIVE: putting [char] in inactive state
because [char]
Explanation The Port Manager was blocked from creating a virtual port for
the switch port and VLAN, causing the port to be inactive. The reason for this
condition is specified in the error message.
Recommended Action Try a different VLAN on the device.
Error Message PM-4-INT_FAILUP: [char] failed to come up. No
internal VLAN available
Explanation The Port Manager failed to allocate the internal VLAN, and the
interface cannot start.
Recommended Action Remove extended-range VLANs to free resources.
Error Message PM-4-INT_VLAN_NOTAVAIL: Failed to allocate internal
VLAN in Port Manager
Explanation The Port Manager failed to find any available internal VLAN.
Recommended Action Delete some extended-range VLANs that are created by
users, or remove some features that require internal VLAN allocation, such
as a routed port.
Error Message PM-4-INVALID_HOST_ACCESS_ENTRY: Invalid Host access
entry type ([dec]) is received
Explanation The host access entry should be either configured or dynamic.
Recommended Action Reconfigure the host access entry using the correct type.
Error Message PM-4-LIMITS:Virtual port count for [char] exceeded
the recommended limit of [dec]
Explanation There is a limit of 1200 virtual ports per module and a maximum
of 4500 per switch. This limit was exceeded.
Recommended Action Reduce the number of trunks and VLANs in the module
(or switch) that is specified in the error message. Make sure that the overture
port and VLAN port count is below the recommended limit.
Error Message PM-4-NO_SUBBLOCK:No PM subblock found for [char]
Explanation A Port Manager (PM) subblock was not found for this interface.
Recommended Action Enter the show tech-support privileged EXEC
command to gather data that might provide information about the error. If you
cannot determine the cause of the error from the error message or from the
show tech-support command display, copy the error message exactly as it
appears on the console or in the system log, contact your technical support
representative, and provide the representative with the gathered information.
Error Message PM-4-PORT_BOUNCED: Port [char] was bounced by [char].
Explanation The Port Manager needed to perform a reactivation of a port in
the link-down state during a switchover. A port is only reactivated when the
port data structures lack consistency between the active and standby
supervisors. The reactivation event returned the active ports in the link-down
state to the link-up state.
Recommended Action This is an informational message only. No action is
required.
Error Message PM-4-PORT_CONSISTENT:Port [char] consistency has
been restored
Explanation The port manager on the standby supervisor engine discovered
that the port state became consistent again.
Recommended Action This is an informational message only. No action is
required.
Error Message PM-4-PORT_INCONSISTENT: Port [char] is inconsistent:
IDB state [char] (set %TE ago)
Explanation The port manager on the standby supervisor engine discovered
that the port state was inconsistent for more that one second. Inconsistent
ports are reactivated on switchover (you will see the PORT_BOUNCED
message).
Recommended Action This is an informational message only. No action is
required.
Error Message PM-4-PVLAN_TYPE_CFG_ERR: Failed to set VLAN [dec] to
a [char] VLAN
Explanation The platform failed to set the private VLAN type.
Recommended Action Enter the show tech-support privileged EXEC
command to gather data that might provide information about the error. If you
cannot determine the cause of the error from the error message or from the
show tech-support command display, copy the error message exactly as it
appears on the console or in the system log, contact your technical support
representative, and provide the representative with the gathered information.
Error Message PM-4-TOO_MANY_APP:application `[char]' exceeded
registration limit
Explanation The Port Manager detected an invalid request. [char] in the
application.
Recommended Action Reconfigure the host access entry using the correct type.
Error Message PM-4-UNKNOWN_HOST_ACCESS: Invalid Host access value
([dec]) is received
Explanation A n invalid host access value was sent to the host access table.
Recommended Action Reconfigure the host access entry using the correct type.
Error Message PM-4-VMPS_CFG: Dynamic access VLAN [dec] same as
voice vlan on [char].
Explanation The access VLAN on the VMPS server is set to the same VLAN
as the voice VLAN on the port.
Recommended Action Change the assignments so that the access VLAN
assignment on the VMPS server is different from the voice VLAN.
PORTFANOUTASIC4X1000MAN Messages
This section contains the Port Fan-out ASIC 4x1000 Manager (PORTFANOUTASIC4X1000MAN) messages. This ASIC takes a gigabit port and fans it out to four 1000-Mb ports.
Error Message C4K_PORTFANOUTASIC4X1000MAN-4-DIAGSFAILED:[char]
failed diagnostics
Explanation The module ASIC that is identified by [char] failed diagnostics.
Recommended Action Contact your technical support representative.
Error Message C4K_PORTFANOUTASIC4X1000MAN-4-FAILEDTOSENDLOOPBACKT
RIES:[char] port [dec] failed to send packet in [dec] tries
Explanation The module ASIC [char] was unable to send a loopback packet
on a module ASIC port for the [dec]th time. The switch has insufficient
memory and will attempt to send a loopback packet only up to three times.
Recommended Action Contact your technical support representative.
Error Message C4K_PORTFANOUTASIC4X1000MAN-4-UNEXPECTEDLOOPBACK:
[char] sent out a loopback packet on port [dec], but it came back
on port [dec]
Explanation The module ASIC diagnostics for [char] sent a loopback packet
out port [dec], and it came back on another port [dec]. This condition is rare
because the loopback is internal to the hardware.
Recommended Action Contact your technical support representative.
PORTFANOUTASIC8X1000HW Messages
This section contains the Port Fan-out ASIC 8x1000 Hardware (PORTFANOUTASIC8X1000HW) message. This ASIC takes a gigabit port and fans it out to eight 1000-Mb ports.
PORTFANOUTASIC8X1000HW-3
Error Message C4K_PORTFANOUTASIC8X1000HW-3-UNKNOWNDEVICEID:
[char] - Linecard Management Protocol info register has unknown
device id [hex]
Explanation Each module ASIC has an information register on it that contains
the device ID field (DID) of the ASIC. When the module ASIC driver read
this register, it discovered that the DID type was invalid.
The [char] field of the DID might contain <asic-code>(x) where x is the gigabit port of the switching engine to which the module ASIC is attached. The hex field of the DID contains the device ID. The expected value is 0x0450.
Recommended Action Contact your technical support representative.
PORTFANOUTASIC8X1000HW-4
Error Message C4K_PORTFANOUTASIC8X1000MAN-4-DIAGSFAILED: [char]
failed diagnostics
Explanation The module ASIC identified by [char] failed diagnostics.
Recommended Action Contact your technical support representative.
Error Message C4K_PORTFANOUTASIC8X1000MAN-4-FAILEDTOSENDLOOPBACKT
RIES: [char] port [dec] failed to send packet in [dec] tries
Explanation The module ASIC [char] is unable to send a loopback packet on
the module ASIC interface [dec] and this is the decth time that it has tried to
send and failed. The switch attempts to send a loopback packet only up to
three times. The switch is out of memory.
Recommended Action Contact your technical support representative.
Error Message C4K_PORTFANOUTASIC8X1000MAN-4-UNEXPECTEDLOOPBACK:
[char] sent out a loopback packet on port [dec], but it came back
on port [dec]
Explanation The module ASIC diagnostics for [char] sent a loopback packet
out interface [dec] and it came back on another interface [dec]. This condition
is unexpected because the loopback is internal to the hardware.
Recommended Action Contact your technical support representative.
PORTFANOUTASIC8X1000HW-7
Error Message C4K_PORTFANOUTASIC8X1000MAN-7-LOSTPACKET: [char]
port [dec] lost one or more packets, [dec] transmitted [dec]
received
Explanation A loopback packet was lost during online diagnostics of the
module ASIC [char].
Recommended Action This is an informational message only. No action is
required.
PORTFANOUTASIC8X100MAN Messages
This section contains the Port Fan-out ASIC 8x100 Manager (PORTFANOUTASIC8X100MAN) messages. This ASIC takes a gigabit port and fans it out to eight 100-Mb ports.
PORTFANOUTASIC8X100MAN-4
Error Message C4K_PORTFANOUTASIC8X100MAN-4-DIAGSFAILED: [char]
failed diagnostics
Explanation The module ASIC that is identified by [char] failed diagnostics.
Recommended Action Contact your technical support representative.
Error Message C4K_PORTFANOUTASIC8X100MAN-4-FAILEDTOSENDLOOPBACKTR
IES:[char] port [dec] failed to send packet in [dec] tries
Explanation The module ASIC [char] was unable to send a loopback packet
on the module ASIC port [dec] for the decth time. The switch has insufficient
memory; it will attempt to send a loopback packet up to three times.
Recommended Action Contact your technical support representative.
Error Message C4K_PORTFANOUTASIC8X100MAN-4-UNEXPECTEDLOOPBACK:
[char] sent out a loopback packet on port [dec], but it came back
on port [dec]
Explanation The module ASIC diagnostics for [char] sent the loopback packet
out port [dec] and it came back on another interface [dec]. This condition is
rare because the loopback is internal to the hardware.
Recommended Action Contact your technical support representative.
PORTFANOUTASIC8X100MAN-7
Error Message C4K_PORTFANOUTASIC8X100MAN-7-LOSTPACKET:[char] port
[dec] lost a packet
Explanation A loopback packet was lost during online diagnostics of this port.
Recommended Action This is an informational message only. No action is
required.
QOS Messages
This section contains the quality of service (QOS) message.
Error Message C4K_QOS-4-OUTOFPOLICERRESOURCES:Out of memory to
allocate a policer
Explanation The software failed to allocate memory for a policer while
processing the QoS configuration, possibly because the policer configuration
exceeded its maximum supported limit.
Recommended Action Remove policers from other unwanted policies, and
retry the operation. Resend the command when other Telnet sessions are not
sending debugging commands.
REDUNDANCY Messages
This section contains the supervisor engine redundancy (REDUNDANCY) messages.
REDUNDANCY-2
Error Message C4K_REDUNDANCY-2-HANDSHAKE_TIMEOUT:The handshake
messaging between active and standby has not yet started.
Explanation The initial handshake message exchange between active and
standby supervisors has not yet started. Though the traffic on the active
supervisor would not be impacted due to this, the redundancy will not work.
Recommended Action Please schedule a downtime ASAP and reset the active
supervisor.
Error Message C4K_REDUNDANCY-2-POSTFAIL_RESET:POST failure on
ACTIVE supervisor detected. [char]
Explanation The active supervisor failed POST but detected the standby
supervisor at bootup. It is attempting to reset itself so that the standby
supervisor can take over as the new active supervisor engine.
Recommended Action You may need to replace the supervisor engine that
failed POST. Contact your technical support representative.
Error Message C4K_REDUNDANCY-2-INCOMPATIBLE_SUPERVISORS: [char]
Explanation For proper operation of redundancy, the supervisor engines must
be of the same model. In this condition redundancy operations are not
available and the standby supervisor is disabled because the supervisors
present are of different models.
Recommended Action Configure the hardware so that the active and standby
supervisors are of the same model.
Error Message C4K_REDUNDANCY-2-IOS_VERSION_CHECK_FAIL: [char]
Explanation The active and standby supervisor engine software is different. In
this condition, redundancy operations are not guaranteed.
Recommended Action Configure the active and standby supervisor engines to
use the same version of software.
Error Message C4K_REDUNDANCY-2-IOS_VERSION_INCOMPATIBLE:[char]
Explanation The system detected an incompatible redundancy condition. The
active supervisor engine is running Cisco IOS Release 12.2 or later releases
and the standby supervisor engine is running Cisco IOS Release 12.1. The
system will reset the standby supervisor engine.
Recommended Action Configure the switch so that the active and standby
supervisor engines are running the same release of Cisco IOS software.
Error Message C4K_REDUNDANCY-2-NON_SYMMETRICAL_REDUNDANT_SYSTEM:
[char]
Explanation The active and standby supervisor engine hardware is different.
In this condition, redundancy operations are not guaranteed.
Recommended Action Configure the hardware so that the active and standby
supervisor engines are identical.
Error Message C4K_REDUNDANCY-2-POSTFAIL:POST failure on [char]
supervisor detected. [char]
Explanation The active supervisor engine failed POST. The current standby
supervisor engine resets the current active supervisor engine to standby and
attempts to become the active supervisor engine. If the standby supervisor
failed POST, then it will suspend at bootup and stay there. During this time if
the active supervisor fails, then the standby supervisor will also reboot
because it is not a fully functional standby supervisor at this point.
Recommended Action Run offline diagnostics on the failed supervisor engine
to isolate the problem.
Error Message C4K_REDUNDANCY-2-POSTFAIL_RESET:POST failure on
ACTIVE supervisor detected. [char]
Explanation The active supervisor engine failed POST but detected the
standby supervisor engine at bootup. The active supervisor engine will reset
itself so that the standby supervisor engine can take over as the new active
supervisor engine.
Recommended Action Run offline diagnostics on the failed supervisor engine
to isolate the failure. Immediate action is not needed for the switch to operate,
but redundancy will not be available until there is a second functional
supervisor engine.
REDUNDANCY-3
Error Message C4K_REDUNDANCY-3-COMMUNICATION: Communication with
the peer Supervisor has been [char]
Explanation The status of the peer supervisor engine communication path
changed.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_REDUNDANCY-3-NOT_READY_FOR_SWITCHOVER: The
active Supervisor failed but standby supervisor cannot initiate
Switchover activity. Resetting standby Supervisor.
Explanation The standby supervisor engine is currently in an intermediate
state and cannot take over for the primary supervisor engine.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_REDUNDANCY-3-PEER_RELOAD: The peer Supervisor is
being reset because [char]
Explanation The supervisor engine was reset for the reason specified by
[char]. See the reported error message for the specific reason. This allows
recovery from an indeterminate standby state.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_REDUNDANCY-3-SIMPLEX_MODE: The peer Supervisor
has been lost
Explanation The peer supervisor engine is absent, and the switch shifted to
nonredundant mode.
Recommended Action This is an informational message only. No action is
required.
REDUNDANCY-4
Error Message C4K_REDUNDANCY-4-CONFIGSYNCFAIL:Persistent-config
Sync to Standby supervisor failed.
Explanation The active supervisor engine failed to receive a confirmation
message from the standby supervisor engine. There is a potential problem
with the standby supervisor engine.
Recommended Action Contact your technical support representative.
Error Message C4K_REDUNDANCY-4-KEEPALIVE_WARNING: Keepalive
messages from peer Supervisor are missing for [dec] seconds
Explanation Keepalive messages have not been sent from the peer supervisor
engine. If the situation persists and the keepalive messages do not resume, the
peer supervisor engine will eventually be reset. This message is logged for
every third missed keepalive message.
Recommended Action This is an informational message only. No action is
required.
REDUNDANCY-5
Error Message C4K_REDUNDANCY-5-CALENDAR: The calendar has been
successfully synchronized to the standby supervisor for the
first time
Explanation The calendar was successfully synchronized to the standby
supervisor for the first time.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_REDUNDANCY-5-CALENDAR_RATELIMIT: The calendar
has been successfully synchronized to the standby supervisor
[dec] times since last calendar syslog
Explanation The calendar was successfully synchronized to the standby
supervisor the specified number of times.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_REDUNDANCY-5-CONFIGSYNC:The [char] has been
successfully synchronized to the standby supervisor
Explanation The configuration was successfully synchronized to the standby
supervisor engine. [char] can be either a private configuration or a startup
configuration.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_REDUNDANCY-5-CONFIGSYNC_RATELIMIT:The [char] has
been successfully synchronized to the standby supervisor
Explanation The configuration was successfully synchronized to the standby
supervisor engine. This is a rate-limited message. These messages are logged
at 1-minute intervals, rather than continuously as with many other messages.
Recommended Action This is an informational message only. No action is
required.
REDUNDANCY-6
Error Message C4K_REDUNDANCY-6-ACTIVESUPNOTFOUND:Active
supervisor not found.
Explanation This message is displayed on the redundant supervisor engine
when it fails to communicate with the active supervisor engine.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_REDUNDANCY-6-ATTEMPTINGTOBECOMEACTIVE:
Attempting to become active supervisor.
Explanation This message is displayed on the standby supervisor engine when
it fails to communicate with the active supervisor engine and attempts to take
over as the active supervisor engine.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_REDUNDANCY-6-DUPLEX_MODE: The peer Supervisor
has been detected
Explanation A peer supervisor engine was detected, and the switch shifted to
duplex mode.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_REDUNDANCY-6-INIT:Initializing as [char]
supervisor
Explanation A supervisor engine that you are connected to is currently
initializing as either the active or standby supervisor engine.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_REDUNDANCY-6-MODE:[char] supervisor initializing
for [char] mode
Explanation The supervisor engine that you are not directly connected to is
currently initializing as either the active or standby supervisor engine in RPR
mode.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_REDUNDANCY-6-SWITCHOVER:Switchover activity
detected
Explanation The standby supervisor engine detected switchover activity.
Recommended Action This is an informational message only. No action is
required.
S2W Messages
This section contains the Calendar (SERVICECARDMAN) messages.
Error Message C4K_S2W-4-READCALENDARERR: Calendar read operation
Failed
Explanation The calendar read operation failed.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_S2W-4-STARTCALENDAROSCILLATORERR: Failed to
start the calendar
Explanation The calendar operation failed to start.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_S2W-4-WRITECALENDARERR: Calendar write operation
Failed
Explanation The system was unable to write to the calendar.
Recommended Action This is an informational message only. No action is
required.
Service Module Messages
This section contains the service module (C4K_SERVICEMODULEHW) message.
Error Message C4K_SERVICEMODULEHW-3-OUTOFMEMORY: Out of memory -
cannot allocate internal buffers for module [dec]
Explanation The switch ran out of temporary buffers.
Recommended Action If this message persists, try resetting the switch.
Error Message C4K_SERVICEMODULEHW-6-RUNREADY: Run ready
notification message received for module [dec]
Explanation Switching module [dec] is connected to the switch and started up
successfully.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_SERVICEMODULEHW-6-EVENTTIMEOUT: Bringup
Handshake timed out for module [dec]
Explanation The supervisor engine did not receive an expected response from
the switching module.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_SERVICEMODULEHW-6-RESETNOTIFY: Reset
notification message received for module [dec]
Explanation Received reset notification for this switching module.
Recommended Action This is an informational message only. No action is
required.
SFF8472 Messages
This section contains the floating-point subsystem (SFF8472) messages.
SFF8472-2
Error Message SFF8472-2-NOMEM: Not enough memory available for
[char]
Explanation The SFF8472 subsystem could not obtain the memory that it
needed.
Recommended Action Contact your technical support representative.
SFF8472-3
Error Message SFF8472-3-INTERNAL_ERROR: [char]
Explanation The SFF8472 subsystem encountered an internal software error.
The error message contains text that can be used to help identify the cause of
the problem.
Recommended Action Contact your technical support representative.
Error Message SFF8472-3-UNEXPECTEDEVENT: Process received unknown
event (maj [hex] min [hex]).
Explanation A process received an event it did not know how to handle. A
process can register to be notified when various events occur in the router.
Recommended Action Contact your technical support representative.
SFF8472-5
Error Message SFF8472-5-THRESHOLD_VIOLATION: [char]: [char];
Operating value: [char]
Explanation There was a threshold violation as specified in the message.
Recommended Action Contact your technical support representative.
SFF8472_FLOAT
Error Message SFF8472_FLOAT-3-INTERNAL_ERROR: [char]
Explanation The SFF8472 floating-point subsystem encountered an internal
software error. The error message contains text that can be used to help
identify the cause of the problem.
Recommended Action Contact your technical support representative.
SPANTREE Messages
This section contains the Spanning Tree Protocol (SPANTREE) messages.
SPANTREE-2
Error Message SPANTREE-2-BLOCK_BPDUGUARD:Received BPDU on port
[char] with BPDU Guard enabled. Disabling port.
Explanation A BPDU was received in the specified interface that has the
spanning tree BPDU guard feature enabled. As a result, the interface was
administratively shut down.
Recommended Action Remove the device sending BPDUs, or disable the
BPDU guard feature. BPDU guard can be locally configured on the interface
or globally configured on all ports that have PortFast enabled. After you
resolve the conflict, reenable the interface by entering the no shutdown
command in interface configuration mode.
Error Message SPANTREE-2-BLOCK_PVID_LOCAL: Blocking [char] on
[char]. Inconsistent local vlan.
Explanation The spanning tree port that is associated with the listed spanning
tree instance [char] and interface [char] is held in spanning tree blocking
state until the port VLAN ID (PVID) inconsistency is resolved. The listed
spanning tree instance is that of the native VLAN ID of the listed interface.
Recommended Action Verify that the configuration of the native VLAN ID is
consistent on the interfaces at each end of the 802.1Q trunk connection. When
the configuration is consistent, spanning tree automatically unblocks the
interfaces.
Error Message SPANTREE-2-BLOCK_PVID_PEER: Blocking [char] on
[char]. Inconsistent peer vlan.
Explanation The spanning tree port (with spanning-tree port ID [char]) that is
associated with the listed instance and interface is held in blocking state until
the port VLAN ID (PVID) inconsistency is resolved. The listed spanning tree
instance is that of the native VLAN ID of the interface on the peer switch to
which the listed interface is connected.
Recommended Action Verify that the configuration of the native VLAN ID is
consistent on the interfaces on each end of the 802.1Q trunk connection.
When corrected, spanning tree automatically unblocks the interfaces.
Error Message SPANTREE-2-CHNL_MISCFG:Detected loop due to
etherchannel misconfiguration of [chars] [chars]
Explanation A misconfigured channel group (with channel group ID [chars])
was detected. For example, the ports of one side of the EtherChannel either
are not configured to be in the channel or failed to bundle, while ports on the
other side of the EtherChannel are successfully bundled.
Recommended Action Locate the misconfigured local ports by entering the
show interfaces status err-disabled command. Check the EtherChannel
configuration on the remote device by entering the show etherchannel
summary command on the remote device. After the configuration is
corrected, enter the shutdown/no shutdown command on the associated
port-channel interface.
Error Message SPANTREE-2-LOOPGUARD_BLOCK: Loop guard blocking port
[char] on [char].
Explanation The spanning tree message age timer expired, because no BPDUs
were received from the designated bridge. Because this condition could be
caused by an unidirectional link failure, the interface is put into blocking state
and marked as loop guard inconsistent in order to prevent possible loops from
being created.
Recommended Action Use the show spanning-tree inconsistentports
command to review the list of interfaces with loop guard inconsistencies.
Determine why devices that are connected to the listed ports are not sending
BPDUs. One reason could be that they do not run the Spanning Tree Protocol;
in this case, you should disable loop guard in the inconsistent interfaces or
start the Spanning Tree Protocol on the other side of the links, depending on
the context. Another reason could be a failure in the cable. If the link has a
failure that makes it unidirectional (you can transmit, but you cannot receive),
you should replace the old cable with a new cable.
Error Message SPANTREE-2-LOOPGUARD_CONFIG_CHANGE: Loop guard
[char] on port [char].
Explanation There was a change in the spanning tree loop guard configuration
for the listed interface. When enabled, the interface will be put into blocking
state and marked as loop guard inconsistent when the message age timer
expires because no BPDUs were received from the designated bridge. This
feature is used to detect unidirectional links.
Recommended Action Verify that this is the desired configuration for the listed
interface. Correct it if this is not the desired configuration; otherwise, no
further action is required.
Error Message SPANTREE-2-LOOPGUARD_UNBLOCK: Loop guard unblocking
port [char] on [char].
Explanation The listed interface received a BPDU, and if the inconsistency
was due to an unidirectional link failure, the problem does not exist anymore.
The loop guard inconsistency is cleared for the interface, which is taken out
of the blocking state.
Recommended Action This is an informational message only. No action is
required.
Error Message SPANTREE-2-PVSTSIM_FAIL: Superior PVST BPDU received
on VLAN [dec] port [char]
Explanation When a PVST+ switch is connected to an MST switch, the IST
root (MSTOO) becomes the root for all PVST+ spanning trees. Looping
occurs if any PVST+ spanning tree has a root with a better preference than
IST. To prevent looping, the port, which is on the MST switch that receives
the superior message from the PVST+ side, is blocked by root guard.
When STP is converging after a new switch or a switch port is added to the topology, this condition occurs transiently. The port unblocks automatically in such cases.
Recommended Action If the port remains blocked, identify the root bridge as
reported in the message, and configure a worse priority for the VLAN
spanning tree. There could be better PVST roots than the message indicates,
and the port will not recover until all such roots are cleared. If you are unsure
whether the roots are cleared, disable and enable the port again.
Error Message SPANTREE-2-RECV_1Q_NON_1QTRUNK: Received 802.1Q BPDU
on non 802.1Q trunk [char] [char].
Explanation A Shared Spanning Tree Protocol (SSTP) bridge protocol data
unit (BPDU) was received on the listed interface. The interface was in trunk
mode but was not using 802.1Q encapsulation. The interface ID is [char].
Recommended Action Verify that the configuration and operational state of the
listed interface and the interface to which it is connected are in the same mode
(access or trunk). If the mode is trunk, verify that both interfaces have the
same encapsulation (ISL or 802.1Q). Once these parameters are consistent,
spanning tree automatically unblocks the interface.
Error Message SPANTREE-2-RECV_BAD_TLV:Received SSTP BPDU with bad
TLV on [char][char].
Explanation The listed interface received an SSTP BPDU that was missing the
VLAN ID tag. The BPDU is discarded. [char] is the interface ID.
Recommended Action If the error message reappears, copy the message exactly
as it appears on the console or in the system log, contact your technical
support representative, and provide the representative with the gathered
information.
Error Message SPANTREE-2-RECV_PVID_ERR: Received BPDU with
inconsistent peer vlan id [dec] on [char] [char]
Explanation The listed interface received an SSTP BPDU that is tagged with
a VLAN ID that does not match the VLAN ID on which the BPDU was
received. This condition occurs when the native VLAN is not consistently
configured on both ends of an 802.1Q trunk. [dec] is the VLAN ID. The
interface ID is [char].
Recommended Action Verify that the configuration of the native VLAN ID is
consistent on the interfaces on each end of the 802.1Q trunk connection. Once
the configuration is consistent, spanning tree automatically unblocks the
interfaces.
Error Message SPANTREE-2-ROOTGUARD_BLOCK: Root guard blocking port
[char] on [char].
Explanation A BPDU was received on the listed interface that advertised a
spanning tree root bridge that was superior to the one already in use. The
interface is put into a blocking state and marked as root guard inconsistent to
prevent a suboptimal spanning tree topology from forming.
Recommended Action Enter the show spanning-tree inconsistentports
command to review the list of interfaces with root guard inconsistencies.
Determine why devices that are connected to the listed ports are sending
BPDUs with a superior root bridge, and then take action to prevent further
occurrences. Once the invalid BPDUs have been stopped, the interfaces
automatically recover and resume normal operation. By looking at the
configuration, ensure that it is appropriate to enable root guard on the
interface.
Error Message SPANTREE-2-ROOTGUARD_CONFIG_CHANGE: Root guard
[char] on port [char].
Explanation There was a change in the spanning tree root guard configuration
for the listed interface. If root guard is enabled, any BPDU that is received on
the interface that advertises a superior spanning tree root bridge to the one
that is already in use will cause the interface to be put into blocking state and
marked as root guard inconsistent.
Recommended Action Verify that this is the correct configuration for the listed
interface. If this is not the correct configuration, change the configuration to
one that is appropriate for the interface.
Error Message SPANTREE-2-ROOTGUARD_UNBLOCK:Root guard unblocking
port [char] on [char].
Explanation The listed interface is no longer receiving BPDUs that are
advertising a superior root bridge. The root guard inconsistency is cleared for
the interface and then is taken out of the blocking state if appropriate.
Recommended Action This is an informational message only. No action is
required.
Error Message SPANTREE-2-UNBLOCK_CONSIST_PORT: Unblocking [char]
on [char]. Port consistency restored.
Explanation The port VLAN ID and/or port type inconsistencies have been
resolved. The Spanning Tree Protocol will unblock the listed interface of the
spanning tree instance. The interface ID is [char].
Recommended Action This is an informational message only. No action is
required.
SPANTREE-3
Error Message SPANTREE-3-BAD_PORTNUM_SIZE:Rejected an attempt to
set the port number field size to [dec] bits (valid range is
[dec] to [dec] bits).
Explanation The spanning tree port identifier is a 16-bit field that is, by
default, divided evenly between the port priority and the port number. Each
subfield is 8 bits wide, allowing the port number field to represent port
numbers between 1 and 255. On systems with more than 255 ports, the STP
subsystem must increase the size of the port number portion of the port ID to
support the greater number of ports. This condition occurs at system
initialization because the maximum number of ports on a particular platform
will not change. This error occurs because of an error in the platform-specific
code that caused it to request more (or fewer) bits than were possible.
Recommended Action Contact your technical support representative.
Error Message SPANTREE-3-PORT_SELF_LOOPED: [char] disabled.-
received BPDU src mac ([mac-addr]) same as that of interface
Explanation A BPDU with a source MAC address that matches the address
assigned to the listed interface was received. A port looped back on itself,
possibly due to a diagnostic cable that was plugged into the interface. The
interface is administratively shut down. [char] is the interface ID.
Recommended Action Check the interface configuration and any cable that is
plugged into the interface. Once the problem is resolved, reenable the
interface by entering the no shutdown command on the interface.
SPANTREE-4
Error Message SPANTREE-4-PORT_NOT_FORWARDING: [char] [char] [char]
[char]
Explanation The specified interface is not in the forwarding state and
forwarding packets.
Recommended Action Contact your technical support representative.
SPANTREE-5
Error Message SPANTREE-5-EXTENDED_SYSID:Extended SysId [char] for
type [char]
Explanation The extended system ID feature was either enabled or disabled
for the given type of spanning tree. If the feature was enabled, the spanning
tree instance identifier is stored in the lower portion of the bridge ID priority
field; this will cause the allowed values for the bridge priority to be limited
to the range of 0 to 61,440, in increments of 4096. If the feature was disabled,
the bridge ID priority field consists entirely of the configured priority, but
some spanning tree features might not be available on a given platform (for
example, 4096 VLAN support).
Recommended Action This is an informational message only. No action is
required.
Error Message SPANTREE-5-ROOTCHANGE: Root Changed for [char]
[dec]: New Root Port is [char]. New Root Mac Address is
[mac-addr]
Explanation The root changed for an instance of spanning tree.
Recommended Action This is an informational message only. No action is
required.
Error Message SPANTREE-5-TOPOTRAP: Topology Change Trap for [char]
[dec]
Explanation A trap was generated to indicate the change in topology.
Recommended Action This is an informational message only. No action is
required.
SPANTREE-6
Error Message SPANTREE-6-PORT_STATE: Port [char] instance [dec]
moving from [char] to [char]
Explanation The spanning tree port changed to another state.
Recommended Action This is an informational message only. No action is
required.
SPANTREE-7
Error Message SPANTREE-7-BLOCK_PORT_TYPE: Blocking [char] on
[char]. Inconsistent port type.
Explanation The listed interface is being held in spanning tree blocking state
until the port type inconsistency is resolved. The port ID is [char].
Recommended Action Verify that the configuration and operational state of the
listed interface and that of the interface to which it is connected are in the
same mode (access or trunk). If the mode is trunk, verify that both interfaces
have the same encapsulation type (ISL or 802.1Q). When these parameters
are consistent, spanning tree automatically unblocks the interface.
Error Message SPANTREE-7-RECV_1Q_NON_TRUNK: Received 802.1Q BPDU
on non trunk [char] [char].
Explanation An SSTP BPDU was received on the listed interface, which is not
an operational trunking interface. The interface ID is [char].
Recommended Action Verify that the configuration and operational state of the
listed interface and that of the interface to which it is connected are in the
same mode (access or trunk). If the mode is trunk, verify that both interfaces
have the same encapsulation type (none, ISL, or 802.1Q). Once these
parameters are consistent, spanning tree automatically unblocks the interface.
Error Message SPANTREE-7-PORTDEL_SUCCESS: [char] deleted from Vlan
[dec]
Explanation The interface was deleted from the specified VLAN.
Recommended Action This is an informational message only. No action is
required.
SPANTREE_FAST
Error Message SPANTREE_FAST-7-PORT_FWD_UPLINK: [char] [char] moved
to Forwarding (UplinkFast).
Explanation The listed interface was selected as the new root port for the
listed spanning tree instance.
Recommended Action This is an informational message only. No action is
required.
SPANTREE_VLAN_SW Messages
This section contains the spanning tree fast convergence (SPANTREE_VLAN_SW) message.
Error Message SPANTREE_VLAN_SW-2-MAX_INSTANCE:Platform limit of
[dec] STP instances exceeded. No instance created for [char]
(port [char]).
Explanation The number of currently active VLAN spanning tree instances
reached a platform-specific limit. No additional VLAN instances will be
created until the number of instances drops below that limit.
Recommended Action Reduce the number of currently active spanning tree
instances by either disabling some of the instances or deleting the VLANs
that are associated with them. You need to manually enable those spanning
trees that cannot be created due to limited instances.
Supervisor Messages
This section contains the supervisor specific (C4K_SUPERVISOR) messages.
Error Message C4K_SUPERVISOR-3-SUPOCTALPHYMDIOREADERR:Failed to
perform read operation on Octal Serdes at address [dec] for the
register at address [dec]
Explanation Unable to read the Octal Serdes on the supervisor.
Recommended Action If this continues to happen, please contact your technical
support representative to replace the supervisor.
Error Message C4K_SUPERVISOR-3-POWERSUPPLYSTATUSREADFAILED:
Failed to read power supply [dec]'s status register
Explanation Reading the power supply status register failed.
Recommended Action Try reinserting the power supply. If the problem persists,
hot swap it with a new power supply.
Error Message C4K_SUPERVISOR-3-SUPOCTALPHYMDIOREADERR: Failed to
perform read operation on Octal Serdes at address [dec] for the
register at address [dec]
Explanation There was an error with the Octal Serdes on the supervisor.
Recommended Action If this continues to happen, please contact your technical
support representative to replace the supervisor.
STORM_CONTROL Messages
This section contains the broadcast storm control (STORM_CONTROL) messages.
Error Message STORM_CONTROL-3-FILTERED: A [char] storm detected on
[char]. A packet filter action has been applied on the interface.
Explanation The amount of traffic detected on the interface exceeded the
configured threshold values. The system filters excess traffic when a packet
is received. The system is not forwarding packet traffic.
Recommended Action Determine and fix the root cause of the excessive traffic
on the interface.
Error Message STORM_CONTROL-3-SHUTDOWN: A packet storm was
detected on [char]. The interface has been disabled.
Explanation The amount of traffic detected on the interface exceeded the
configured threshold values. Because the interface was configured to be shut
down if a packet storm event is detected, it was placed in an errdisable state.
Recommended Action If automatic recovery is preferred, the errdisable
recovery mechanism can be used. Determine and fix the root cause of the
excessive traffic on the interface.
STORE Messages
This section contains the storage (STORE) message.
Error Message C4K_STORE-2-OUTOFCHUNKS:Out of chunks of memory
Explanation The system has insufficient memory.
Recommended Action Reboot the switch. If this message reoccurs, add
additional memory.
SUPERVISOR Messages
This section contains the supervisor (SUPERVISOR) messages.
SUPERVISOR-2
Error Message C4K_SUPERVISOR-2-ALLCHASSISSEEPROMSINVALID:
Contents of all chassis's serial eeproms are invalid
Explanation The contents of all of the serial EEPROMs in the chassis are
invalid; they might have a bad checksum. In a nonredundant chassis, the
single serial EEPROM is bad. If this is a redundant chassis, both serial
EEPROMs are bad.
Recommended Action Power cycle the switch. If the problem persists, contact
your technical support representative. You will probably need to return the
switch for service.
Error Message C4K_SUPERVISOR-2-MUXBUFFERNOTPRESENT:Mux buffer
(WS-X4K-MUX) [dec] is not present
Explanation The WS-X4K-MUX line card is either not connected to the
backplane properly or is not present. If the line card present in this slot cannot
be identified, its SEEPROM cannot be read and it will be unusable.
Recommended Action Contact your technical support representative. You will
probably need to return the backplane for repair.
Error Message C4K_SUPERVISOR-2-SUPERVISORSEEPROMINVALID:Contents
of supervisor's serial eeprom are invalid
Explanation The contents of the supervisor engine's serial EEPROM are
invalid (bad checksum, for example). This condition could occur if the
supervisor engine is seated incorrectly.
Recommended Action Remove and reinsert the supervisor engine. If that action
does not work, power cycle the switch. If the switch still fails to come online,
contact your technical support representative. You will probably need to
return the supervisor engine for repair.
SUPERVISOR-3
Error Message C4K_SUPERVISOR-3-BACKPLANESEEPROMREADFAILED:Failed
to read backplane's serial eeprom, read [dec], expected size
[dec]
Explanation A failure occurred when reading the backplane serial EEPROM.
Recommended Action Power cycle the switch. If the problem persists, contact
your technical support representative. You will probably need to return the
backplane for repair.
Error Message C4K_SUPERVISOR-3-CHASSISTYPEMISMATCHINSPROM:Chassis
type in supervisor's FPGA register and chassis' serial eeprom
don't match
Explanation The chassis type in the field programmable gate array (FPGA)
register on the supervisor engine does not match the type that is listed in the
serial EEPROM on the chassis. This message should occur only in a
prototype switch used in an early field trial.
Recommended Action Check the chassis serial EEPROM information. Contact
your technical support representative; you may need to return some switch
components for repair or replacement.
Error Message C4K_SUPERVISOR-3-CLOCKMODULESEEPROMINVALID:Invalid
Clock Module seeprom data
Explanation The clock module serial EEPROM cannot be read or has not been
programmed. This message should occur only in a prototype switch used in
an early field trial.
Recommended Action Check the chassis serial EEPROM information. Contact
your technical support representative. You may need to return some switch
components for repair or replacement.
Error Message C4K_SUPERVISOR-3-CLOCKMODULESEEPROMREADFAILED:
Failed to read clock module's seeprom
Explanation A failure occurred while reading the clock module serial
EEPROM. This message should occur only in a prototype switch used in an
early field trial.
Recommended Action Check the chassis serial EEPROM information. Contact
your technical support representative. You may need to return some switch
components for repair or replacement.
Error Message C4K_SUPERVISOR-3-FANTRAYREADFAILED: Failed to read
system fan tray status register from hardware
Explanation The fan tray presence was detected, but the system failed to read
the fan tray status register contents.
Recommended Action If this message appears only once, this could be a
transient error and no action is required. If this message appears repeatedly
(once every 10 minutes), replace the system fan tray.
Error Message C4K_SUPERVISOR-3-FANTRAYSEEPROMREADFAILED: Failed to
read fan tray's seeprom
Explanation A failure occurred while reading the system fan tray serial
EEPROM. This message should occur only in a prototype switch used in an
early field trial.
Recommended Action Check the chassis serial EEPROM information. Contact
your technical support representative. You may need to return some switch
components for repair or replacement.
Error Message C4K_SUPERVISOR-3-FANTRAYSEEPROMINVALID:Invalid fan
tray seeprom data
Explanation The fan tray serial EEPROM cannot be read or was not
programmed. This message should occur only in a prototype switch used in
an early field trial.
Recommended Action Check the chassis serial EEPROM information. Contact
your technical support representative. You may need to return some switch
components for repair or replacement.
Error Message C4K_SUPERVISOR-3-FIRSTCHASSISSEEPROMINVALID:
Contents of chassis's first serial eeprom are invalid
Explanation The contents of the first serial EEPROM are invalid (for example,
a bad checksum). This message appears only on a Catalyst 4507R switch
using the redundancy feature, which means that there is a second serial
EEPROM.
Recommended Action Power cycle the switch. If the serial EEPROM is still
invalid, contact your technical support representative. You may need to return
some switch components for repair or replacement.
Error Message C4K_SUPERVISOR-3-INVALIDMGMTETHERNETADDR:Chassis
SPROM not set or invalid MAC address range
Explanation The out-of-band management port uses a MAC address from the
system MAC address range. The contents of the serial programmable
read-only memory (SPROM) are bad, so the management port does not have
a MAC address.
Recommended Action Power cycle the switch. If the serial EEPROM is still
invalid, contact your technical support representative. You may need to return
some switch components for repair or replacement.
Error Message C4K_SUPERVISOR-3-MUXBUFFERLOOPBACKFAILED: Failed to
put [char] supervisor's module [dec] muxbuffers in loopback
Explanation The serial-to-wire write operation to put the line card mux
buffers in loopback failed. This might indicate problems with the line card
mux buffers in the Catalyst 4500 series chassis.
Recommended Action Power cycle the switch. If the serial EEPROM is still
invalid, contact your technical support representative. You may need to return
some switch components for repair or replacement.
Error Message C4K_SUPERVISOR-3-MUXBUFFERREADLOOPBACKFAILED:
Failed to read whether [char] supervisor's module [dec]
muxbuffers are in loopback
Explanation The serial-to-wire write operation to put the line card mux
buffers in loopback failed. This might indicate problems with the line card
mux buffers in the Catalyst 4500 series chassis.
Recommended Action Power cycle the switch. If the serial EEPROM is still
invalid, contact your technical support representative. You may need to return
some switch components for repair or replacement.
Error Message C4K_SUPERVISOR-3-MUXBUFFERSEEPROMINVALID:Invalid
data in mux buffer [dec]'s serial eeprom
Explanation The mux buffer serial EEPROM cannot be read or was not
programmed.
Recommended Action Power cycle the switch. If the serial EEPROM is still
invalid, contact your technical support representative. You may need to return
some switch components for repair or replacement.
Error Message C4K_SUPERVISOR-3-MUXBUFFERSEEPROMREADFAILED: Failed
to read mux buffer [dec]'s serial eeprom
Explanation A failure occurred while reading the mux buffer serial EEPROM.
Recommended Action Power cycle the switch. If the serial EEPROM is still
invalid, contact your technical support representative. You may need to return
some switch components for repair or replacement.
Error Message C4K_SUPERVISOR-3-NETFLOWCARDSEEPROMINVALID: Invalid
Netflow Services Card seeprom data
Explanation The serial EEPROM on the NetFlow Services Card cannot be
read or was not programmed.
Recommended Action For more information, enter the sprom read nffc
command at the ROMMON prompt.
Error Message C4K_SUPERVISOR-3-NETFLOWCARDSEEPROMREADFAILED:
Netflow Services Card seeprom read failed
Explanation A reading of the serial EEPROM on the NetFlow Services Card
failed.
Recommended Action For more information, enter the sprom read nffc
command at the ROMMON prompt.
Error Message C4K_SUPERVISOR-3-NETFLOWCARDSEEPROMUNKNOWNTYPE:
Unknown Netflow Services Card revision: Read fru major/minor
([hex],[hex]) but expected ([hex],[hex]).
Explanation The serial EEPROM on the NetFlow Services Card has a revision
that is not compatible with this release of software. The card will be ignored.
Recommended Action For more information, enter the sprom read nffc
command at the ROMMON prompt.
Error Message C4K_SUPERVISOR-3-OLDWSX4124:WS-X4124-FX-MT revision
[dec].[dec], which is < 1.6, is not supported
Explanation The WS-X4124-FX-MT modules with hardware revisions 1.6 or
earlier are not supported.
Recommended Action Replace this module with a WS-X4124-FX-MT module
revision 1.6 or later.
Error Message C4K_SUPERVISOR-3-POWERSUPPLYSTATUSREADFAILED:Failed
to read power supply [dec]'s status register
Explanation Reading the power supply status register failed.
Recommended Action Try reinserting the power supply. If the message
persists, hot swap it with a new power supply.
Error Message C4K_SUPERVISOR-3-POWERSUPPLYSEEPROMREADFAILED:
Failed to read power supply [dec]'s serial eeprom
Explanation A failure occurred while reading the power supply serial
EEPROM.
Recommended Action Reinsert the power supply. If that does not work, replace
the old power supply with a new power supply.
Error Message C4K_SUPERVISOR-3-POWERSUPPLYSEEPROMINVALID:Invalid
data in power supply [dec]'s serial eeprom
Explanation The power supply serial EEPROM cannot be read or was not
programmed.
Recommended Action Reinsert the power supply. If that does not work, replace
the old power supply with a new power supply.
Error Message C4K_SUPERVISOR-3-RETIMERDISABLEFAILED:Failed to
disable the retimer of the active supervisor's uplink.
Explanation The retimer on the active supervisor engine cannot be initialized.
In a redundant system, you might see packets that are transmitted out the
active supervisor engine's nonactive uplink.
Recommended Action Disconnect the second uplink on the active supervisor
engine.
Error Message C4K_SUPERVISOR-3-RETIMERINITFAILED:Failed to
initialize the retimer of the active supervisor's uplink.
Explanation The retimer on the active supervisor engine cannot be initialized.
In a redundant system, you might see packets that are transmitted out the
active supervisor engine's nonactive uplink.
Recommended Action Disconnect the second uplink on the active supervisor
engine.
Error Message C4K_SUPERVISOR-3-SEEPROMREADFAILED:Failed to read
supervisor's serial eeprom, try reinserting supervisor
Explanation A reading of the supervisor engine's serial EEPROM failed. The
read might fail if the module is not seated correctly in the slot.
Recommended Action Remove and reinsert the module. If that does not work,
power cycle the switch. If the read still fails, contact your technical support
representative. You may need to return some switch components for repair or
replacement.
Error Message C4K_SUPERVISOR-3-VEO2SEEPROMMISPROGRAMMED: The
seeprom has a FRU minor type of 335. It must be reprogrammed to
343.
Explanation Early WS-X4248-RJ45V module prototypes had their
SEEPROM FRU minor type programmed as 335. The correct value is 343.
Recommended Action You can fix this value by using the ROMMON's SPROM
write command. The WS-X4248-RJ45V module will not work until you fix
this condition.
SUPERVISOR-4
Error Message C4K_SUPERVISOR-4-INLINEVOLTAGEOUTOFRANGE:Output
voltage of the on-board inline power convertor on this board is
[char] and is outside the expected range of [char]
Explanation This message should only occur in systems using a Supervisor
Engine II-Plus TS. The output voltage of the on-board inline power converter
is outside its expected valid range. This condition can occur because of failed
PoE components, one or more powered devices drawing more power than
expected, or because of problems with the 12 V output of the system power
supply.
Recommended Action Use the show power detail and show power inline
module 1 commands to verify that the devices drawing PoE are using the
expected amount of power, and disconnect them if they are drawing more than
desired. If the power supply LEDs are not green, verify at the source that the
system power input is correct. If the problem persists, contact your technical
support representative. You will probably need to replace the supervisor
engine.
Error Message C4K_SUPERVISOR-4-OTHERSUPERVISORACTIVEDEBOUNCE:Othe
r supervisor is still holding hardware lock
Explanation This condition is detected when the redundancy register
incorrectly indicates that the other supervisor engine is holding a lock. This
error is probably caused by hardware signal latency. Unless there is a real
hardware failure, the switch automatically recovers from this state. If there is
a persistent hardware failure, this message appears four times.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_SUPERVISOR-4-SUPMGMTMACFATALRXERR:Supervisor
MAC device type [hex] reset due to a fatal Rx error
Explanation An error occurred with the out-of-band management port on the
supervisor engine.
Recommended Action This is an informational message only. No action is
required.
SUPERVISOR-7
Error Message C4K_SUPERVISOR-7-BACKPLANESEEPROMWRITEFAILED:Failed
to write backplane's serial eeprom
Explanation The writing of the backplane serial EEPROM failed.
Recommended Action Power cycle the switch.
Error Message C4K_SUPERVISOR-7-SEEPROMWRITEFAILED:Failed to write
supervisor's serial eeprom
Explanation The software was unable to write to the supervisor engine serial
EEPROM.
Recommended Action Remove and reinsert the module. If this message
reappears, reboot the switch. If the switch is still unable to write to the
EEPROM, contact your technical support representative.
SWITCH-QOS-TB Messages
This section contains the Switch QoS Manager (SWITCH-QOS-TB) messages.
Error Message SWITCH_QOS_TB-5-TRUST_DEVICE_DETECTED: [char]
detected on port [char], port set to trusted
Explanation Software detected that a device matching the trusted device
boundary setting for the interface and changed the trust state for the interface
to trusted.
Recommended Action This is an informational message only. No action is
required.
Error Message SWITCH_QOS_TB-5-TRUST_DEVICE_LOST: [char] no longer
detected on port [char], port set to untrusted
Explanation The system lost contact with a trusted device and changed the
trust state for the interface to untrusted.
Recommended Action This is an informational message only. No action is
required.
SW_DAI Messages
This section contains the dynamic ARP inspection (DAIMAN) messages.
SW_DAI-4
Error Message SW_DAI-4-ACL_DENY: [dec]Invalid ARPs (Req) on
[chars], vlan [dec].
Explanation The switch received ARP packets that are considered invalid by
ARP inspection. The packets are invalid, and their presence indicates that
administratively denied packets are in the network. This log message
generates when packets have been denied by ACLs either explicitly or
implicitly (with static ACL configuration). The presence of these packets
indicates a possible "man-in-the-middle" attacks in the network.
Recommended Action To stop these messages from generating, find the source
host of these packets and stop the host from sending them.
Error Message SW_DAI-4-DHCP_SNOOPING_DENY: [dec] Invalid ARPs
(Req) on [chars], vlan [chars].
Explanation The switch received ARP packets that are considered invalid by
ARP inspection. The packets are invalid, and their presence may be an
indication of "man-in-the-middle" attacks that are attempted in the network.
This message is logged when the IP address and MAC address binding for the
sender on the received VLAN is not listed in the DHCP snooping database.
Recommended Action To stop these messages from generating, find the source
host of these packets and stop the host from sending them.
Error Message SW_DAI-4-INVALID_ARP: [dec] Invalid ARPs (Req) on
[chars], vlan [chars].
Explanation The switch received ARP packets that are considered invalid by
ARP inspection. The packets are invalid and do not pass one or more of the
source MAC address, destination MAC address, or IP address validation
checks. A packet was denied because the source MAC address, destination
MAC address, or IP validation failed.
Recommended Action To stop these messages from generating, find the source
host of these packets and stop the host from sending them.
Error Message SW_DAI-4-PACKET_BURST_RATE_EXCEEDED: [dec] packets
received in [dec] seconds on [char].
Explanation The switch received [dec] number of ARP packets in the
specified burst interval. The interface was in the errdisabled state and the
switch received the packets at a rate higher than the configured packet rate for
every second over the configured burst interval. The message is logged just
before the interface entered the errdisabled state and if the configured burst
interval is more than one second.
Recommended Action This is an informational message only. No action is
required.
Error Message SW_DAI-4-PACKET_RATE_EXCEEDED: [dec] packets
received in [dec] milliseconds on [char].
Explanation The switch received [dec] number of ARP packets in the
specified duration on the given interface above the exceeded packet rate. This
message is logged just before the interface entered the errdisabled state and
when the burst interval is set to one second.
Recommended Action This is an informational message only. No action is
required.
Error Message SW_DAI-4-SPECIAL_LOG_ENTRY: [dec] Invalid ARP
packets [%CC]
Explanation The switch received [dec] number of ARP packets that the ARP
inspection considers invalid. The packets are invalid, and their presence may
be an indication of "man-in-the-middle" attacks attempted on the network.
This message displays when the rate of incoming packets exceed the DAI
logging rate.
Recommended Action This is an informational message only. No action is
required.
SW_DAI-6
Error Message SW_DAI-6-ACL_PERMIT: [dec] ARPs (Req) on [chars],
vlan [chars].
Explanation The switch received ARP packets that have been permitted
because of an ACL match.
Recommended Action This is an informational message only. No action is
required.
Error Message SW_DAI-6-DHCP_SNOOPING_PERMIT: [dec] ARPs (Req) on
[chars], vlan [chars]
Explanation The switch received ARP packets that have been permitted
because the IP and MAC address for the sender match against the DHCP
snooping database for the received VLAN.
Recommended Action This is an informational message only. No action is
required.
SW-VLAN Messages
This section contains the Switch VLAN Manager (SW-VLAN) messages.
SW-VLAN-3
Error Message SW_VLAN-3-VLAN_PM_NOTIFICATION_FAILURE: VLAN Manager
synchronization failure with Port Manager over [char]
Explanation Due to a lack of ready pool space, the VLAN Manager dropped a
notification from the Port Manager.
Recommended Action This is an informational message only. No action is
required.
Error Message SW_VLAN-3-VTP_PROTOCOL_ERROR: VTP protocol code
internal error: [char]
Explanation The VTP protocol code encountered an unexpected error while
processing a configuration request, packet, or timer expiration.
Recommended Action This is an informational message only. No action is
required.
SW-VLAN-4
Error Message SW_VLAN-4-BAD_PM_VLAN_COOKIE_RETURNED: VLAN manager
unexpectedly received a bad PM VLAN cookie from the Port Manager
Explanation The VLAN Manager received an upcall from the Port Manager
containing a VLAN cookie that translated to a bad VLAN number.
Recommended Action This is an informational message only. No action is
required.
Error Message SW_VLAN-4-BAD_STARTUP_VLAN_CONFIG_FILE: Failed to
configure VLAN from startup-config. Fallback to use VLAN
configuration file from non-volatile memory
Explanation The VLAN software failed to use the VLAN configuration from
a startup-config file. The software will use the binary VLAN configuration
file in nonvolatile memory.
Recommended Action This is an informational message only. No action is
required.
Error Message SW_VLAN-4-BAD_VLAN_CONFIGURATION_FILE: VLAN
configuration file contained incorrect verification word: [hex]
Explanation The VLAN configuration file begins with an unrecognized value
and might not be a valid VLAN configuration file. The file was rejected.
Recommended Action This is an informational message only. No action is
required.
Error Message SW_VLAN-4-BAD_VLAN_CONFIGURATION_FILE_VERSION: VLAN
configuration file contained unknown file version: [dec]
Explanation When the VLAN Manager read the VLAN configuration file it
contained an unrecognized file version number. This could indicate an
attempt to regress to an older version of the VLAN Manager software.
Recommended Action This is an informational message only. No action is
required.
Error Message SW_VLAN-4-BAD_VLAN_TIMER_ACTIVE_VALUE: Encountered
incorrect VLAN timer active value: [char]
Explanation Due to a software error, a VLAN timer was detected as being
active when it should have been inactive or inactive when it should have been
detected as being active.
Recommended Action This is an informational message only. No action is
required.
Error Message SW_VLAN-4-EXT_VLAN_INTERNAL_ERROR: Extended VLAN
manager received an internal error [dec] from [char]: [char]
Explanation The VLAN Manager received an unexpected error code from the
extended VLAN configuration software.
Recommended Action This is an informational message only. No action is
required.
Error Message SW_VLAN-4-EXT_VLAN_INVALID_DATABASE_DATA: Extended
VLAN manager received bad data of type [char]: value [dec] from
function [char]
Explanation The extended VLAN Manager received invalid data from an
extended VLAN configuration database routine.
Recommended Action This is an informational message only. No action is
required.
Error Message SW_VLAN-4-IFS_FAILURE: VLAN manager encountered file
operation error: call = [char] / file = [char] / code = [dec]
([char]) / bytes transferred = [dec]
Explanation The VLAN Manager received an unexpected error return from a
Cisco IOS file system call.
Recommended Action This is an informational message only. No action is
required.
Error Message SW_VLAN-4-NO_PM_COOKIE_RETURNED: VLAN manager
unexpectedly received a null [char] type cookie from the Port
Manager
Explanation The VLAN Manager queried the Port Manager for a reference
cookie but received a NULL pointer instead.
Recommended Action This is an informational message only. No action is
required.
Error Message SW_VLAN-4-STARTUP_EXT_VLAN_CONFIG_FILE_FAILED:
Failed to configure extended range VLAN from startup-config.
Error [char]
Explanation The VLAN software failed to use extended VLAN configuration
in the startup-config file. Configuration information for all extended-range
VLANs will be lost when the system boots.
Recommended Action This is an informational message only. No action is
required.
Error Message SW_VLAN-4-VLAN_CREATE_FAIL: Failed to create VLANs
[char]: [char]
Explanation The VLANs specified in the error message could not be created.
The VLAN manager called a VLAN database routine to create one or more
VLANs, but the Port Manager could not complete the VLAN creation
requests. A possible cause of this error is that the VLANs already exist in the
Port Manager as internal VLANs.
Recommended Action Contact your technical support representative.
Error Message SW_VLAN-4-VTP_INTERNAL_ERROR: VLAN manager received
an internal error [dec] from vtp function [char]: [char]
Explanation The VLAN Manager received an unexpected error code from the
VTP configuration software.
Recommended Action This is an informational message only. No action is
required.
Error Message SW_VLAN-4-VTP_INVALID_DATABASE_DATA: VLAN manager
received bad data of type [char]: value [dec] from vtp database
function [char]
Explanation The VLAN Manager received invalid data from a VTP
configuration database routine.
Recommended Action This is an informational message only. No action is
required.
Error Message SW_VLAN-4-VTP_INVALID_EVENT_DATA: VLAN manager
received bad data of type [char]: value [dec] while being called
to handle a [char] event
Explanation The VLAN Manager received invalid data from the VTP
configuration software.
Recommended Action This is an informational message only. No action is
required.
Error Message SW_VLAN-4-VTP_USER_NOTIFICATION: VTP protocol user
notification: [char]
Explanation The VTP protocol code encountered an unusual diagnostic
condition.
Recommended Action This is an informational message only. No action is
required.
Error Message SW_VLAN-4-VTP_SEM_BUSY: VTP semaphore is unavailable
for function [char]. Semaphore locked by [char]
Explanation The VTP database is currently locked by another task and is not
available. Retry the operation later.
Recommended Action Retry the operation later.If the problem persists, contact
your technical support representative.
SW-VLAN-6
Error Message SW_VLAN-6-OLD_CONFIG_FILE_READ: Old version [dec]
VLAN configuration file detected and read OK. Version [dec] files
will be written in the future.
Explanation The VLAN software detected an old version of the VLAN
configuration file format. The VLAN software was able to interpret the file
with no problems, but it will create files using the new format in the future.
Recommended Action This is an informational message only. No action is
required.
Error Message SW_VLAN-6-VTP_MODE_CHANGE: VLAN manager changing
device mode from [char] to [char].
Explanation Some switch devices must automatically change VTP device
modes upon receipt of a VLAN configuration database containing more than
a set number of VLANs, depending on the device. Such a spontaneous
conversion occurred, what the previous mode was, and what the current mode
is.
Recommended Action This is an informational message only. No action is
required.
SWITCHINGENGINEMAN Messages
This section contains the switching engine management (SWITCHINGENGINEMAN) messages.
SWITCHINGENGINEMAN-2
Error Message C4K_SWITCHINGENGINEMAN-2-PACKETMEMORYERROR3:
Persistent Errors in Packet Memory [dec]
Explanation There is a high rate of persistent errors in packet memory. This
condition might indicate a persistent hardware problem.
Recommended Action If this message persists, use the show platform
commands to show results, contact your technical support representative, and
provide the representative with the gathered information.
SWITCHINGENGINEMAN-3
Error Message C4K_SWITCHINGENGINEMAN-3-BADDELIMITER:Recived CPU
packet with bad delimiter
Explanation The software expected a delimiter pattern of successive packets
but received some other pattern. This condition might be due to a loss of
synchronization between the hardware and the software.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_SWITCHINGENGINEMAN-3-BADLENGTH:Recived CPU
packet with bad length
Explanation The switch received a CPU packet that was either too long or too
short.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_SWITCHINGENGINEMAN-3-CIMPKTBUFPARITYERROR:
Parity error in Cim Packet Buffer at offset [dec]
Explanation There is a parity error in queue memory. This condition might
indicate a transient hardware problem or a more permanent problem. After
128 packet memory and queue memory errors, the switch reboots.
Recommended Action If you see this message often, reboot the switch.
Error Message C4K_SWITCHINGENGINEMAN-3-ERRORINTERRUPT: Error
condition detected by hardware. Interrupt Status [hex]
Explanation The hardware detected an error condition and raised an interrupt
to the software. The interrupt status value indicates the type of error.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_SWITCHINGENGINEMAN-3-JUMBOPACKET:Recieved a
Jumbo CPU packet
Explanation The switch received a packet that is larger than 2032 bytes. This
large packet is called a jumbo packet.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_SWITCHINGENGINEMAN-3-NOMEMORYFORRXRING: Not
enough memory to initialize CPU packets
Explanation The system ran out of memory while trying to initialize the CPU
packet driver.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_SWITCHINGENGINEMAN-3-PACKETENGINERESTARTED: An
error happened in the Packet Engine logic
Explanation The packet engine logic became unstable for unknown reasons.
Recommended Action Reboot the switch.
Error Message C4K_SWITCHINGENGINEMAN-3-PACKETMEMORYERROR2:
Multiple Errors in Packet Memory [dec]
Explanation Multiple errors in packet memory were detected. If this message
persists, it might indicate a hardware problem.
Recommended Action If this message persists, use the show platform
commands to show results, contact your technical support representative, and
provide the representative with the gathered information.
Error Message C4K_SWITCHINGENGINEMAN-3-PACKETMEMORYPARITYERROR:
Parity error in Packet Memory at address [dec] , total errors=
[dec]
Explanation There is a parity error in packet memory. This condition might
indicate a transient hardware problem or a more permanent problem. After
128 packet memory and queue memory errors, the switch reloads
automatically.
Recommended Action If this message reoccurs, reboot the switch. If the
message appears every time the switch boots, run the show diagnostics
online command and send the results to your technical support
representative.
Error Message C4K_SWITCHINGENGINEMAN-3-PACKETMEMORYTESTFAILURE:Pa
cket Memory buffer test failed!!! Insufficient packet buffers
are available to continue booting.
Explanation The packet memory diagnostic bootup test detected too many
failures for switch operation to continue.
Recommended Action Refer to the Release Note attachment in the DDTS for
CSCdz57255.
Error Message C4K_SWITCHINGENGINEMAN-3-PACKETMEMORYTESTPARTIALFAI
LURE:Packet Memory buffer test detected errors with [dec] % of
the packet buffers. Switch operation will continue, with
potentially reduced performance. Use 'show diagnostic result
module all detail' command to see test results.
Explanation The packet memory diagnostic bootup test detected failures, but
there are still a sufficient number of working buffers to enable switch
operation.
Recommended Action Use the show diagnostic result module all detail
command to see the test results. Refer to the Release Note attachment in the
DDTS for CSCdz57255.
Error Message C4K_SWITCHINGENGINEMAN-3-TRANSMITQUEUESINIT:Tx
Queues initialized multiple ( [dec] ) times
Explanation The transmit queues had to be initialized multiple times because
unexpected packets were seen in the queues.
Recommended Action No action is required. If the message appears every time
the switch boots, run the show diagnostics online command and send the
results to your technical support representative.
Error Message C4K_SWITCHINGENGINEMAN-3-QUEUEMEMORYPARITYERROR:Par
ity error in Queue Memory, addr=[hex], total errors=%u
Explanation There is a parity error in the queue memory. This condition might
indicate a transient hardware problem or a more permanent problem. After
128 packet memory and queue memory errors, the switch reloads.
Recommended Action If this message reoccurs, reboot the switch.
Error Message C4K_SWITCHINGENGINEMAN-3-TRANSMITQUEUESINIT:Tx
Queues initialized multiple [dec] times
Explanation The transmit queues had to be initialized multiple times.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_SWITCHINGENGINEMAN-3-RXDELIMITERERROR: Invalid
packet delimiter received. Expected [hex] Received [hex]
Explanation Successive packets that are sent by the hardware to the CPU have
a specific delimiter pattern. The software expected a delimiter pattern but
received some other pattern. This condition might be caused by
synchronization loss between the hardware and the software.
Recommended Action Reboot the switch.
SWITCHINGENGINEMAN-4
Error Message C4K_SWITCHINGENGINEMAN-4-PACKETMEMORYERROR: Error in
Packet Memory [dec]
Explanation An error in packet memory was detected. If this message persists,
it might indicate a hardware problem.
Recommended Action If this message persists, use the show platform
commands to show results, contact your technical support representative, and
provide the representative with the gathered information.
Error Message C4K_SWITCHINGENGINEMAN-4-SYSTEMNOTRESET: System has
already been reset [dec] times due to Packet Memory errors.
System will not be reset anymore
Explanation The software detected a large number of errors in the packet
memory and reset the switch. This condition indicates a hardware problem.
However, the system only reset [dec] times by software to prevent an
auto-boot followed by a reset loop.
Recommended Action Replace the switch. If you do not replace the switch,
errors may persist and the system will reset again.
SWITCHMANAGER Messages
This section contains the Switching Manager (SWITCHMANAGER) messages.
SWITCHMANAGER-3
Error Message C4K_SWITCHMANAGER-3-DUPLICATESWPHYPORT: Internal
Event: Tried to create new sw PimPhyport [char], but it already
exists
Explanation This message is a debug message that is used by developers only
and should not occur during operation.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_SWITCHMANAGER-3-DUPLICATESWPORT: Internal Event:
Tried to create new sw PimPort [char], but it already exists
Explanation This message is a debug message that is used by developers only
and should not occur during operation.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_SWITCHMANAGER-3-SSOACTIVEPORTACKTIMEOUT:
Internal Event: timed out after [dec] iterations waiting for
Standby to acknowledge port status change for [char]
Explanation There is probably a software failure creating a communication
problem between the active supervisor engine and the standby supervisor
engine. SSO Redundancy mode cannot operate reliably when this condition
occurs.
Recommended Action Contact your technical support representative.
Error Message C4K_SWITCHMANAGER-3-SSOHARDWAREACKTIMEOUT: Internal
Event: timed out after [dec] iterations waiting for the [char]
hardware to be programmed
Explanation The active supervisor engine is taking more time than usual to
program the hardware. This should not affect normal behavior or SSO
functionality. In the worst case you may see link flaps when the supervisor
engines switch over.
Recommended Action This is an informational message only. No action is
required. If the problem persists, contact your technical support
representative.
SWITCHMANAGER-4
Error Message C4K_SWITCHMANAGER-4-CANTPOWEROFF:Internal Error:
PimEthAutoNegotiator - Can't power off port [char]
Explanation This is an internal software error in an inline-power state
machine.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_SWITCHMANAGER-4-CANTPOWERON:Internal Error:
PimEthAutoNegotiator - Can't power on port [char]
Explanation This is an internal software error in an inline-power state
machine.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_SWITCHMANAGER-4-HARDWAREERROR:Power management
hardware for port [char] bad.
Explanation The switch cannot change the inline-power state for this port.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_SWITCHMANAGER-4-S2WERROR:Power control to port
[char] bad. Possibly power is turned on.
Explanation This is a communication error in PoE power management.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_SWITCHMANAGER-4-S2WERRORREPORT: PimEthAutoNeg:
S2w Read/Write Error for port [char].
Explanation A read/write error occurred on the specified port.
Recommended Action Refer to the release notes to verify whether you can see
all the symptoms described for CSCef87815. If you do not and do not see any
adverse effect on the functionality of the PoE linecards (WS-X4248-RJ45V,
WS-X4248-RJ21V, WS-X4548-RJ45V, WS-X4224-RJ45V or
WS-X4524-RJ45V), then treat this message an informational message only
and no action is required.
Error Message C4K_SWITCHMANAGER-4-SSOEANWARNPORTRESET: The state
of the port [char] is unknown after switchover, resetting its
link.
Explanation A new switching module was inserted, and the active supervisor
engine crashed unexpectedly before it could communicate the state of ports
on the new module to the standby supervisor engine. The standby supervisor
engine will assume that the port's link is down.
Recommended Action This is an informational message only. No action is
required.
SWITCHMANAGER-5
Error Message C4K_SWITCHMANAGER-5-FLAPSHUTDOWN:Temporarily
disabling port [char] due to flap
Explanation The specified port is going up and down (link up/down) in rapid
succession. This condition is usually caused by a bad connection or problems
with the link-level hardware. The switch will temporarily shut down the
problem port. Every 5 seconds, the switch reenables the port to see if the
problem has gone away. If not, the port will remain shut down indefinitely.
Recommended Action This is an informational message only. No action is
required.
SWNETFLOWMAN Messages
This section contains the Software NetFlow Manager (SWNETFLOWMAN) messages.
SWNETFLOWMAN-4
Error Message C4K_SWNETFLOWMAN-4-FLOWSTATISTICSLOST: Flow rate too
high. [dec] packet byte count statistics update lost
[object-info]
Explanation The Cisco IOS flow uses 32-bit counters to store bytes per flow.
The NetFlow Services Card engine uses 39-bit counters. When the switch
reports a flow byte count that is greater than 32 bits, it stores the first 32 bits
and logs a warning message.
Recommended Action This is an informational message only. No action is
required.
Error Message C4K_SWNETFLOWMAN-4-NETFLOWCACHEFULL: Netflow
hardware-software map cache full. Could not create a map.
Explanation The switch uses a map to correlate flow in the software with
corresponding flows in the hardware. This map is full and the switch cannot
create any more mappings. This is a very rare condition. The switch is
running at full capacity.
Recommended Action This is an informational message only. No action is
required.
SWNETFLOWMAN-6
Error Message C4K_SWNETFLOWMAN-6-FIXEDCREATIONTIME:Fixed creation
time of [dec] flows.
Explanation The system did not record the creation time of a flow. In this case,
the system determined a creation time, which is usually the same time that
was used for the last flow.
Recommended Action If this message reoccurs frequently, and you see that the
system is fixing a lot of flows, contact your technical support representative.
SYSMAN Messages
This section contains the System Manager (SYSMAN) messages.
SYSMAN-2
Error Message C4K_SYSMAN-2-POWERONSELFTESTFAIL:Supervisor module
in slot [dec] failed Power-On-Self-Test(POST). Line cards are
**NOT** initialized. Please use 'show diagnostics result module
[dec]test <tid> detail' command for details.
Explanation A power-on self test (POST) failure is detected on the supervisor
engine. When this occurs, the modules are not initialized.
Recommended Action Use the show diagnostics result module dec test tid
detail command to isolate the problem. Reset the switch after you have
resolved the supervisor engine failure.
SYSMAN-3
Error Message C4K_SYSMAN-3-LINECARDDIAGSFAILED:Module in slot
[dec] failed online diagnostics. Please use 'show diagnostics
result module [dec]test <tid> detail' command for details.
Explanation A module failed online diagnostics. When this occurs, all the
module's ports are flagged as faulty and cannot be used until the problem is
resolved.
Recommended Action Remove and reinsert the module. If the problem persists,
copy the message exactly as it appears on the console or in the system log,
contact your technical support representative, and provide the representative
with the gathered information.
Error Message C4K_SYSMAN-3-LINECARDDIAGSPARTIALFAILURE:Partial
failure on module [dec]. Please use 'show diagnostics result
module [dec]test <tid> detail' command for details.
Explanation Some of the module's ports have failed online diagnostics.
Recommended Action Remove and reinsert the switch. If the problem persists,
copy the message exactly as it appears on the console or in the system log,
contact your technical support representative, and provide the representative
with the gathered information.
SYSMAN-4
Error Message C4K_SYSMAN-4-MORETHANONEDEBUGCOMMANDEXECUTING:Canno
t execute '[char]' right now, please try again later
Explanation More than one Telnet session issued a debugging command at the
same time. Only one Telnet session can issue a debugging command at the
same time. All Telnet sessions receive this message, except the Telnet session
that issued the command first.
Recommended Action Try the command when other Telnet sessions are not
issuing debugging commands.
TRANSCIEVER Messages
This section contains the TRANSCEIVER subsystem messages.
Error Message TRANSCEIVER-3-INTERNAL_ERROR: [char]
Explanation The TRANSCEIVER subsystem encountered an internal
software error. The error message contains text that can be used to help
identify the cause of the problem.
Recommended Action Contact your technical support representative.
Error Message TRANSCEIVER-3-LAYER_CHANGE_ERROR: Error changing
layer for port [char]
Explanation The TRANSCEIVER subsystem encountered an internal
software error while changing the layer for this port.
Recommended Action Contact your technical support representative.
UFAST_MCAST_SW Messages
This section contains the UplinkFast (UFAST_MCAST_SW) messages.
UFAST-3
Error Message UFAST_MCAST_SW-3-PROC_START_ERROR:UplinkFast
packets will not be transmitted as the process could not be
created.
Explanation The UplinkFast packets will not be transmitted as the process
cannot be created.
Recommended Action Reload UplinkFast. If this problem persists even after
the reload, copy the message exactly as it appears on the console or in the
system log, contact your technical support representative, and provide the
representative with the gathered information.
UFAST-4
Error Message UFAST_MCAST_SW-4-MEM_NOT_AVAILABLE:No memory is
available for transmitting UplinkFast packets on Vlan [dec].
Explanation UplinkFast packets are not transmitted on VLAN [dec] due to a
lack of memory.
Recommended Action Reduce other system activity to ease memory demands.
Contact your technical support representative to determine whether you need
to upgrade to a larger memory configuration.
VQPCLIENT Messages
This section contains VLAN Query Protocol (VQP) Client messages.
VQPCLIENT-2
Error Message VQPCLIENT-2-CHUNKFAIL: Could not allocate memory for
VQP
Explanation An error occurred when the system tried to allocate memory for
the VQP client.
Recommended Action Copy the message exactly as it appears on the console or
in the system log, contact your technical support representative, and provide
the representative with the gathered information.
Error Message VQPCLIENT-2-DENY: Host [enet] denied on interface
[chars]
Explanation The VLAN Membership Policy Server (VMPS) denied access for
the given host MAC address to an interface. [enet] is the host MAC address,
and [chars] is the interface name.
Recommended Action This is an informational message only. No action is
required. If you think that the host should have been allowed access, verify
the configuration on the VMPS.
Error Message VQPCLIENT-2-INITFAIL: Platform-specific VQP
initialization failed. Quitting
Explanation An error occurred during initialization of the VQP client
platform-specific code.
Recommended Action Copy the message exactly as it appears on the console or
in the system log, contact your technical support representative, and provide
the representative with the gathered information.
Error Message VQPCLIENT-2-IPSOCK: Could not obtain IP socket
Explanation An error occurred when the system attempted to open an IP
socket to the VMPS.
Recommended Action If the error message recurs, copy the message exactly as
it appears on the console or in the system log, contact your technical support
representative, and provide the representative with the gathered information.
Error Message VQPCLIENT-2-PROCFAIL: Could not create process for
VQP. Quitting
Explanation An error occurred while creating a process for the VQP client.
Recommended Action Copy the message exactly as it appears on the console or
in the system log, contact your technical support representative, and provide
the representative with the gathered information.
Error Message VQPCLIENT-2-SHUTDOWN: Interface [chars] shutdown by
VMPS
Explanation The VMPS directed that an interface be shut down. [chars] is the
interface name.
Recommended Action This is an informational message only. No action is
required. If you think that the port should not have been shut down, then
verify the configuration on the VMPS.
Error Message VQPCLIENT-2-TOOMANY: Interface [chars] shutdown by
active host limit
Explanation The system shut down an interface because too many hosts have
requested access to that port. [chars] is the interface name.
Recommended Action To reactivate the port, remove the excess hosts, and enter
the no shutdown interface configuration command on the interface.
VQPCLIENT-3
Error Message VQPCLIENT-3-IFNAME: Invalid interface ([char]) in
response
Explanation The VMPS sent an unsolicited response with an unknown
interface name. [chars] is the name of the unknown interface.
Recommended Action Verify the VMPS configuration.
Error Message VQPCLIENT-3-THROTTLE: Throttling VLAN change on
[chars]
Explanation An attempt was made to change the VLAN assignment for an
interface more often than once every 10 seconds. The VLAN change is
denied. [chars] is the name of the interface.
Recommended Action This is an informational message only. No action is
required. If this message reoccurs, verify the VMPS configuration and that
unexpected hosts are not connected to the port.
Error Message VQPCLIENT-3-VLANNAME: Invalid VLAN ([chars]) in
response
Explanation VMPS specified a VLAN name that is unknown to the switch.
[chars] is the invalid VLAN name.
Recommended Action Make sure that the VLAN exists on the switch. Verify
the VMPS configuration.
VQPCLIENT-7
Error Message VQPCLIENT-7-NEXTSERV: Trying next VMPS
Explanation The system lost connectivity with the current VMPS and is
changing to the next server in its list.
Recommended Action This is an informational message only. No action is
required.
Error Message VQPCLIENT-7-PROBE: Probing primary server
[IP_address]
Explanation The system is trying to reestablish connectivity with the primary
VMPS at the given IP address.
Recommended Action This is an informational message only. No action is
required.
Error Message VQPCLIENT-7-RECONF: Reconfirming VMPS responses
Explanation The switch is reconfirming all responses with the VMPS.
Recommended Action This is an informational message only. No action is
required.
WATCHDOG Messages
This section contains the watchdog (WATCHDOG) message.
Error Message C4K_WATCHDOG-3-CHILDFAILURE:Watchdog failure
([char]) - system may reset
Explanation The job [char] was unscheduled and not started soon enough to
start its watchdog timer.
Recommended Action Determine what other activity is utilizing the supervisor
engine.