This example shows how to set the power supply in slot A to off:
Switch# power supply 1 slot A off
Disabling Power supply A may result in a power loss to PoE devices and/or switches ... Continue? (yes/[no]): yes
Switch#
Jun 10 04:52:54.389: %PLATFORM_ENV-6-FRU_PS_OIR: FRU Power Supply 1 powered off
Jun 10 04:52:56.717: %PLATFORM_ENV-1-FAN_NOT_PRESENT: Fan is not present
Switch#
This example shows how to set the power supply in slot A to on:
Switch# power supply 1 slot A on
Jun 10 04:54:39.600: %PLATFORM_ENV-6-FRU_PS_OIR: FRU Power Supply 1 powered on
This example shows the output of the show env power command:
Switch# show env power
SW PID Serial# Status Sys Pwr PoE Pwr Watts
--- ------------------ ---------- --------------- ------- ------- -----
1A PWR-C1-715WAC LIT161010UE OK Good Good 715
1B Not Present
Switch#
Table 2 show env power Status Descriptions Field |
Description |
OK
|
The power supply is present and power is good.
|
Not Present
|
No power supply is installed.
|
No Input Power
|
The power supply is present but there is no input power.
|
Disabled
|
The power supply and input power are present, but power supply is switched off by CLI.
|
Not Responding
|
The power supply is not recognizable or is faulty.
|
Failure-Fan
|
The power supply fan is faulty.
|