Catalyst 3850 Switch Hardware Installation Guide
Technical Specifications

Table Of Contents

Technical Specifications

Switch Specifications

Power Supply Module Specifications

Fan Module Specifications


Technical Specifications


Switch Specifications

Power Supply Module Specifications

Fan Module Specifications

Switch Specifications

Table A-1 Environmental and Physical Specifications 

Environmental Ranges

Operating1 temperature

23 to 113° F (-5 to 45° C)

Storage temperature

-40 to 158° F (-40 to 70° C)

Relative humidity

5 to 95% (non-condensing)

Operating altitude

Up to 10,000 ft (3,000 m)

Physical Specifications

Dimensions (H x W x D)

1.73 x 17.5 x 17.5 in. (4.4 x 44.5 x 44.5 cm)

(with the FAN FRUs installed but without the power supplies installed)

Weight

Catalyst 3850 24-port PoE switches

Catalyst 3850 24-port non PoE switches

Catalyst 3850 48-port non PoE switches

Catalyst 3850 48-port PoE switches

(weights do not include the network modules, power supplies, or blanks).

13.3 lb (6.0 kg)

13.1 lbs (6.0 kg)

14.2 lbs (6.5 kg)

14.4 lbs (6.5)

1 Minimum ambient temperature for cold start is 32° F (0° C)


Power Supply Module Specifications

Table A-2 Environmental and Physical Specifications for the AC- and DC-Power Supply Modules 

Environmental Ranges

Operating temperature

AC power supply: 23 to 113° F (-5 to 45° C)

DC power supply: 23 to 131° F (-5 to 55° C)

Storage temperature

-40 to 158° F (-40 to 70° C)

Relative humidity

10 to 95% (non-condensing)

Altitude

AC power supply: Up to 10,000 ft (3,000 m)

DC power supply: Up to 13,000 ft (4,000 m)

Physical Specifications

Weight

PWR-C1-1100WAC

PWR-C1-715WAC

PWR-C1-350WAC

PWR-C1-440WDC=

 

3 lb (1.4 kg)

2.8 lb (1.3 kg)

2.6 lb (1.2 kg)

2.6 lb (1.2 kg)

Dimensions (H x D x W)

PWR-C1-1100WAC

PWR-C1-715WAC

PWR-C1-350WAC

PWR-C1-440WDC=

 

1.58 x 11.72 x 3.25 in. (3.5 x 29.8 x 8.3 cm)

1.58 x 10.22 x 3.25 in. (3.5 x 26 x 8.3 cm)

1.58 x 10.22 x 3.25 in. (3.5 x 26 x 8.3 cm)

1.58 x 10.22 x 3.25 in. (3.5 x 26 x 8.3 cm)

Note Dimensions shown exclude the extraction handle, which measures 1.55 in. (3.9 cm) and the keying feature which measures 0.44 in (1.1 cm).


Table A-3 Power Specifications for AC Power 24- and 48-Port Switches 

Power Specifications

Maximum output power

PWR-C1-1100WAC: 1100 W
PWR-C1-715WAC: 715 W
PWR-C1-350WAC: 350 W

Input voltage range and frequency

PWR-C1-1100WAC: 1100-W, 115 to 240 VAC (autoranging)
50 to 60 Hz
PWR-C1-715WAC: 715 W, PWR-C1-350WAC: 350 W,
100 to 240 VAC (autoranging), 50 to 60 Hz

Input current

PWR-C1-1100WAC:12-6 A
PWR-C1-715WAC: 10-5 A
PWR-C1-350WAC: 4-2 A

Output ratings

PWR-C1-1100WAC: -56 V@19.64 A
PWR-C1-715WAC: -56 V@12.8 A
PWR-C1-350WAC: -56 V@6.25 A

Total input BTU1

PWR-C1-1100WAC: 4263 BTUs per hour, 1250 W
PWR-C1-715WAC: 2742 BTUs per hour, 804 W
PWR-C1-350WAC: 1357 BTUs per hour, 398 W

Total output BTU1

PWR-C1-1100WAC: 3751 BTUs per hour, 1100 W
PWR-C1-715WAC: 2438 BTUs per hour, 765 W
PWR-C1-350WAC: 1194 BTUs per hour, 350 W

1 The total input and total output BTU ratings refer to input power to the power supply and output power to the switch. The BTU ratings are based on 100 VAC for the 350-W and 715-W power supplies and 115 VAC for the 1100-W power supply.


Table A-4 Power Specifications for DC-Power 24- and 48-Port Switches 

Power Specifications

Maximum output power

PWR-C1-440WDC: 440 W

Input current

PWR-C1-440WDC: 16 -8 A

DC input voltage

PWR-C1-440WDC: -36 to -72 VDC

Output ratings

PWR-C1-440WDC: -56 V@7.86 A

Voltage range domestic

PWR-C1-440WDC: -36 VDC (minimum) -48 VDC (nominal), -72 VDC (maximum)

Voltage range international

PWR-C1-440WDC: -36 VDC (minimum) -60 VDC (nominal), -72 VDC (maximum)

Total input BTU1

PWR-C1-440WDC 1841 BTUs per hour, 540 W

Total output BTU1

PWR-C1-440WDC: 1502 BTUs per hour, 440 W

Wire gauge for ground connection

PWR-C1-440WDC: 12 AWG or 8 AWG

Branch circuit protection

PWR-C1-440WDC: 20 A

1 The total input and total output BTU ratings refer to input power to the power supply and output power to the switch. The BTU ratings are based on -36 VDC.


Fan Module Specifications

Table A-5 Fan Module Environmental and Physical Specifications 

Environmental Ranges

Operating temperature

23 to 176° F (-5 to 80° C)

Storage temperature

-40 to 185° F (-40 to 85° C)

Relative humidity

5 to 95% (non-condensing)

Altitude

Up to 13,000 ft (4,000 m)

Physical Specification

Dimensions (H x D x W)

1.62 x 1.73 x 4.24 in. (4.11 x 4.39 x 10.76 cm)

Weight

0.2 lb (0.07 kg)

Operating Specification

Airflow

20 cfm