Table Of Contents
service password-recovery
service-policy
set
setup express
show access-lists
show auto qos
show boot
show class-map
show cluster
show cluster candidates
show cluster members
show controllers ethernet-controller
show controllers lre cpe
show controllers lre actual
show controllers lre admin
show controllers lre link monitor
show controllers lre log
show controllers lre profile
show controllers lre sequence
show controllers lre status
show controllers lre version
show controllers utilization
show dot1x
show env
show errdisable recovery
show etherchannel
show file
show flowcontrol
show interfaces
show interfaces counters
show inventory
show ip access-lists
show ip dhcp snooping
show ip dhcp snooping binding
show ip igmp profile
show ip igmp snooping
show ip igmp snooping querier detail
show lacp
show lre upgrade
show mac access-group
show mac address-table
show mac address-table multicast
show mac address-table notification
show mls masks
show mls qos interface
show mls qos maps
show monitor
show mvr
show mvr interface
show mvr members
show pagp
show parser macro
show policy-map
show port-security
show rps
show running-config vlan
show setup express
show spanning-tree
show storm-control
show system mtu
show udld
show version
show vlan
show vmps
show vtp
show wrr-queue bandwidth
show wrr-queue cos-map
shutdown
shutdown vlan
snmp-server enable traps
snmp-server host
snmp trap mac-notification
spanning-tree backbonefast
spanning-tree bpdufilter
spanning-tree bpduguard
spanning-tree cost
spanning-tree etherchannel guard misconfig
spanning-tree extend system-id
spanning-tree guard
spanning-tree link-type
spanning-tree loopguard default
spanning-tree mode
spanning-tree mst configuration
spanning-tree mst cost
spanning-tree mst forward-time
spanning-tree mst hello-time
spanning-tree mst max-age
spanning-tree mst max-hops
spanning-tree mst port-priority
spanning-tree mst priority
spanning-tree mst root
spanning-tree port-priority
spanning-tree portfast (global configuration)
spanning-tree portfast (interface configuration)
spanning-tree stack-port
spanning-tree uplinkfast
spanning-tree vlan
speed
storm-control
switchport access
switchport block
switchport host
switchport mode
switchport nonegotiate
switchport port-security
switchport port-security aging
switchport priority extend
switchport protected
switchport trunk
switchport voice vlan
system mtu
2
service password-recovery
Use the service password-recovery global configuration command to enable the password-recovery mechanism (the default). An end user with physical access to the switch can hold down the Mode button and interrupt the boot process while the switch is powering up and can assign a new password. Use the no form of this command to disable part of the password-recovery functionality. When the password-recovery mechanism is disabled, interrupting the boot process is allowed only if the user agrees to set the system back to the default configuration.
service password-recovery
no service password-recovery
This command is available only on Catalyst 2950 Long-Reach Ethernet (LRE) switches.
Syntax Description
This command has no arguments or keywords.
Defaults
The password-recovery mechanism is enabled.
Command Modes
Global configuration
Command History
Release
|
Modification
|
12.1(11)YJ
|
This command was introduced.
|
Usage Guidelines
This command is valid only on Catalyst 2950 LRE switches.
As a system administrator, you can use the no service password-recovery command to disable some of the functionality of the password recovery feature by allowing an end user to reset a password only by agreeing to return to the default configuration.
The password-recovery mechanism has been triggered, but
is currently disabled. Access to the boot loader prompt
through the password-recovery mechanism is disallowed at
this point. However, if you agree to let the system be
reset back to the default system configuration, access
to the boot loader prompt can still be allowed.
Would you like to reset the system back to the default configuration (y/n)?
If the user chooses not to reset the system back to the default configuration, the normal boot process continues, as if the Mode button had not been pressed. If you choose to reset the system back to the default configuration, the configuration file in flash memory is deleted and the VLAN database file, flash:vlan.dat (if present) is deleted.
Note
If you use the no service password-recovery command to control end user access to passwords, we recommend that you save a copy of the config file in a location away from the switch in case the end user uses the password recovery procedure and sets the system back to default values. Do not keep a backup copy of the config file on the switch.
If the switch is operating in VTP transparent mode, we recommend that you also save a copy of the vlan.dat file in a location away from the switch.
You can verify if password recovery is enabled or disabled by entering the show version privileged EXEC command.
Examples
This example shows how to disable password recovery on a switch so that a user can only reset a password by agreeing to return to the default configuration:
Switch(config)# no service-password recovery
Related Commands
Command
|
Description
|
show version
|
Displays version information for the hardware and firmware.
|
service-policy
Use the service-policy interface configuration command to apply a policy map defined by the policy-map command to the input of a particular interface. Use the no form of this command to remove the policy map and interface association.
service-policy input policy-map-name
no service-policy input policy-map-name
This command is available only if your switch is running the enhanced software image (EI).
Syntax Description
policy-map-name
|
Apply the specified policy map to the input of an interface.
|
Defaults
No policy maps are attached to the interface.
Command Modes
Interface configuration
Command History
Release
|
Modification
|
12.1(6)EA2
|
This command was introduced.
|
Usage Guidelines
Only one policy map per ingress interface is supported.
Service policy maps cannot be defined on egress interfaces.
Note
For more information about configuring access control lists (ACLs), see the "Configuring Network Security with ACLs" chapter in the software configuration guide for this release.
Examples
This example shows how to apply plcmap1 to an ingress interface:
Switch(config)# interface gigabitethernet0/17
Switch(config-if)# service-policy input plcmap1
You can verify your settings by entering the show policy-map privileged EXEC command.
Related Commands
Command
|
Description
|
policy-map
|
Creates or modifies a policy map that can be attached to multiple interfaces to specify a service policy.
|
show policy-map
|
Displays quality of service (QoS) policy maps.
|
set
Use the set policy-map class configuration command to classify IP traffic by setting a Differentiated Services Code Point (DSCP) value. Use the no form of this command to remove traffic classification.
set ip dscp new-dscp
no set ip dscp new-dscp
This command is available only if your switch is running the enhanced software image (EI).
Syntax Description
new-dscp
|
New DSCP value assigned to the classified traffic.
The supported DSCP values are 0, 8, 10, 16, 18, 24, 26, 32, 34, 40, 46, 48, and 56.
|
Defaults
No traffic classification is defined.
Command Modes
Policy-map class configuration
Command History
Release
|
Modification
|
12.1(6)EA2
|
This command was introduced.
|
Usage Guidelines
The set command can be used in a policy with a match command.
The set command sets the DSCP value for in-profile packets.
Note
This command does not support IP precedence.
To return to policy-map configuration mode, use the exit command. To return to privileged EXEC mode, use the end command.
Note
For more information about configuring access control lists (ACLs), see the "Configuring Network Security with ACLs" chapter in the software configuration guide for this release.
Examples
This example shows how to assign a DSCP value of 10 to all FTP traffic without any policers:
Switch(config)# policy-map policy_ftp
Switch(config-pmap)# class ftp_class
Switch(config-pmap-c)# set ip dscp 10
Switch(config-pmap)# exit
You can verify your settings by entering the show policy-map privileged EXEC command.
Related Commands
Command
|
Description
|
police
|
Defines a policer for classified traffic.
|
policy-map
|
Creates or modifies a policy map that can be attached to multiple interfaces to specify a service policy.
|
show policy-map
|
Displays quality of service (QoS) policy maps.
|
setup express
Use the setup express global configuration command to enable Express Setup mode on the switch. This is the default setting. Use the no form of this command to disable Express Setup mode.
setup express
no setup express
This command is available only on Catalyst 2950 switches.
Syntax Description
This command has no arguments or keywords.
Defaults
Express Setup is enabled.
Command Modes
Global configuration
Command History
Release
|
Modification
|
12.1(14)EA1
|
This command was introduced.
|
Usage Guidelines
When Express Setup is enabled on a new (unconfigured) switch, pressing the Mode button for 2 seconds activates Express Setup. You can access the switch through an Ethernet port by using the IP address 10.0.0.1 and then can configure the switch with the web-based Express Setup program or the command-line interface (CLI)-based setup program.
When you press the Mode button for 2 seconds on a configured switch, the mode LEDs start blinking. If you press the Mode button for a total of 10 seconds, the switch configuration is deleted, and the switch reboots. The switch can then be configured like a new switch, either through the web-based Express Setup program or the CLI-based setup program.
Note
As soon as you make any change to the switch configuration (including entering no at the beginning of the CLI-based setup program), configuration by Express Setup is no longer available. You can only run Express Setup again by pressing the Mode button for 10 seconds. This deletes the switch configuration and reboots the switch.
If Express Setup is active on the switch, entering the write memory or copy running-configuration startup-configuration privileged EXEC commands deactivates Express Setup. The IP address 10.0.0.1 is no longer valid on the switch, and your connection using this IP address ends.
The primary purpose of the no setup express command is to prevent someone from deleting the switch configuration by pressing the Mode button for 10 seconds.
Examples
This example shows how to enable Express Setup mode:
Switch(config)# setup express
You can verify that Express Setup mode is enabled by pressing the Mode button:
•
On an unconfigured switch, the mode LEDs begin blinking green after 2 seconds.
•
On a configured switch, the mode LEDs turn solid green after a total of 10 seconds.
Caution 
If you
hold the Mode button down for a total of 10 seconds, the configuration is deleted, and the switch reboots.
This example shows how to disable Express Setup mode:
Switch(config)# no setup express
You can verify that Express Setup mode is disabled by pressing the Mode button. The mode LEDs only turn solid green or begin blinking green if Express Setup mode is enabled on the switch.
Related Commands
Command
|
Description
|
show setup express
|
Displays if Express Setup mode is active on the switch.
|
show access-lists
Use the show access-lists privileged EXEC command to display access control lists (ACLs) configured on the switch.
show access-lists [name | number] [ | {begin | exclude | include} expression]
Syntax Description
name
|
(Optional) Name of the ACL.
|
number
|
(Optional) ACL number. The range is 1 to 2699.
|
| begin
|
(Optional) Display begins with the line that matches the expression.
|
| exclude
|
(Optional) Display excludes lines that match the expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
Privileged EXEC
Command History
Release
|
Modification
|
12.1(6)EA2
|
This command was introduced.
|
Usage Guidelines
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show access-lists command:
Switch# show access-lists
Standard IP access list testingacl
Standard IP access list wizard_1-1-1-2
Extended IP access list 103
permit tcp any any eq www
Extended IP access list CMP-NAT-ACL
Dynamic Cluster-HSRP deny ip any any
Dynamic Cluster-NAT permit ip any any
permit ip host 10.123.222.192 any
permit ip host 10.228.215.0 any
permit ip host 10.245.137.0 any
permit ip host 10.245.155.128 any
permit ip host 10.221.111.64 any
permit ip host 10.216.25.128 any
permit ip host 10.186.122.64 any
permit ip host 10.169.110.128 any
permit ip host 10.146.106.192 any
Related Commands
show auto qos
Use the show auto qos user EXEC command to display the quality of service (QoS) commands entered on the interfaces on which automatic QoS (auto-QoS) is enabled.
show auto qos [interface [interface-id]]
This command is available only if your switch is running the enhanced software image (EI).
Syntax Description
interface [interface-id]
|
(Optional) Display auto-QoS information for the specified interface or for all interfaces. Valid interfaces include physical ports.
|
Command Modes
User EXEC
Command History
Release
|
Modification
|
12.1(12c)EA1
|
This command was introduced.
|
12.1(20)EA2
|
The information in the command output changed, and the user guidelines were updated.
|
Usage Guidelines
In releases earlier than Cisco IOS Release 12.1(20)EA2, the show auto qos [interface [interface-id]] command output shows the initial generated auto-QoS configuration.
In Cisco IOS Release 12.1(20)EA2 or later, the show auto qos command output shows only the auto-QoS command entered on each interface. The show auto qos interface interface-id command output shows the auto-QoS command entered on a specific interface.
Use the show running-config privileged EXEC command to display the auto-QoS configuration and the user modifications.
To display information about the QoS configuration that might be affected by auto-QoS, use one of these commands:
•
show mls qos
•
show mls qos map cos-dscp
•
show mls qos interface
•
show running-config
•
show wrr-queue bandwidth
•
show wrr-queue cos-map
Examples
This is an example of output from the show auto qos command after the auto qos voip cisco-phone and the auto qos voip cisco-softphone interface configuration commands are entered:
auto qos voip cisco-phone
auto qos voip cisco-softphone
auto qos voip cisco-phone
This is an example of output from the show auto qos interface interface-id command when
the auto qos voip cisco-phone interface configuration command is entered:
Switch> show auto qos interface fastethernet0/3
auto qos voip cisco-phone
This is an example of output from the show running-config privileged EXEC command when the auto qos voip cisco-phone and the auto qos voip cisco-softphone interface configuration commands are entered:
Switch# show running-config
Building configuration...
wrr-queue bandwidth 10 20 70 1
wrr-queue cos-map 3 3 6 7
class-map match-all AutoQoS-VoIP-RTP-Trust
class-map match-all AutoQoS-VoIP-Control-Trust
policy-map AutoQoS-Police-SoftPhone
class AutoQoS-VoIP-RTP-Trust
police 1000000 4096 exceed-action drop
class AutoQoS-VoIP-Control-Trust
police 1000000 4096 exceed-action drop
mls qos map cos-dscp 0 8 16 26 32 46 48 56
interface FastEthernet0/3
mls qos trust device cisco-phone
auto qos voip cisco-phone
interface FastEthernet0/4
service-policy input AutoQoS-Police-SoftPhone
auto qos voip cisco-softphone
These are examples of output from the show auto qos command when auto-QoS is disabled on the switch:
AutoQoS not enabled on any interface
These are examples of output from the show auto qos interface interface-id command when auto-QoS is disabled on an interface:
Switch> show auto qos interface fastethernet0/1
Related Commands
Command
|
Description
|
auto qos voip
|
Automatically configures QoS for VoIP within a QoS domain.
|
show boot
Use the show boot privileged EXEC command to display the settings of the boot environment variables.
show boot [ | {begin | exclude | include} expression]
Syntax Description
| begin
|
(Optional) Display begins with the line that matches the expression.
|
| exclude
|
(Optional) Display excludes lines that match the expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
Privileged EXEC
Command History
Release
|
Modification
|
12.1(11)EA1
|
This command was introduced.
|
Usage Guidelines
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Note
Only the software can read and write a copy of the private configuration file. You cannot read, write, delete, or display a copy of this file.
Examples
This is an example of output from the show boot command. Table 2-8 describes each field in the output.
BOOT path-list: flash:boot
Config file: flash:config.text
Private Config file: flash:private-config.text
Table 2-8 show boot Field Descriptions
Field
|
Description
|
BOOT path-list
|
Displays a semicolon-separated list of executable files to load and to execute when automatically booting.
If the BOOT environment variable is not set, the system attempts to load and execute the first executable image it can find by using a recursive, depth-first search through the flash file system. In a depth-first search of a directory, each encountered subdirectory is completely searched before continuing the search in the original directory.
If the BOOT variable is set but the specified images cannot be loaded, the system attempts to boot the first bootable file that it can find in the flash file system.
|
Config file
|
Displays the filename that the software uses to read and write a nonvolatile copy of the system configuration.
|
Private Config file
|
Displays the filename that the software uses to read and write a nonvolatile copy of the private configuration.
|
Enable Break
|
Displays whether a break during booting is enabled or disabled. If it is set to yes, on, or 1, you can interrupt the automatic boot process by pressing the Break key on the console after the flash file system is initialized.
|
Manual Boot
|
Displays whether the switch automatically or manually boots. If it is set to no or 0, the boot loader attempts to automatically boot the system. If it is set to anything else, you must manually boot the switch from the boot loader mode.
|
Helper path-list
|
Displays a semicolon-separated list of loadable files to dynamically load during the boot loader initialization. Helper files extend or patch the functionality of the boot loader.
|
NVRAM/Config file buffer size
|
Displays the buffer size that the software uses to hold a copy of the configuration file in memory. The configuration file cannot be larger than the buffer size allocation.
|
Related Commands
Command
|
Description
|
boot private-config-file
|
Specifies the filename that the software uses to read and write a nonvolatile copy of the private configuration.
|
show class-map
Use the show class-map user EXEC command to display quality of service (QoS) class maps, which define the match criteria to classify traffic.
show class-map [class-map-name] [ | {begin | exclude | include} expression]
This command is available only if your switch is running the enhanced software image (EI).
Syntax Description
class-map-name
|
(Optional) Display the contents of the specified class map.
|
| begin
|
(Optional) Display begins with the line that matches the expression.
|
| exclude
|
(Optional) Display excludes lines that match the expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
User EXEC
Command History
Release
|
Modification
|
12.1(6)EA2
|
This command was introduced.
|
Usage Guidelines
If you do not specify a class-map-name, all class maps appear.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show class-map test command:
Switch> show class-map test
Class Map match-all test (id 2)
Match access-group name testingacl
This is an example of output from the show class-map command:
Class Map match-all wizard_1-1-1-2 (id 3)
Match access-group name videowizard_1-1-1-2
Class Map match-all test (id 2)
Match access-group name testingacl
Class Map match-any class-default (id 0)
Class Map match-all class1 (id 5)
Class Map match-all classtest (id 4)
Description: This is a test.
Match access-group name testingacl
Related Commands
Command
|
Description
|
class-map
|
Creates a class map to be used for matching packets to the class whose name you specify.
|
match
|
Defines the match criteria to classify traffic.
|
show cluster
Use the show cluster privileged EXEC command to display the cluster status and a summary of the cluster to which the switch belongs. This command can be entered on command and member switches.
show cluster [ | {begin | exclude | include} expression]
Syntax Description
| begin
|
(Optional) Display begins with the line that matches the expression.
|
| exclude
|
(Optional) Display excludes lines that match the expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
Privileged EXEC
Command History
Release
|
Modification
|
12.0(5.2)WC(1)
|
This command was introduced.
|
Usage Guidelines
On a member switch, this command displays the identity of the command switch, the switch member number, and the state of its connectivity with the command switch.
On a command switch, this command displays the cluster name and the total number of members. It also shows the cluster status and time since the status changed. If redundancy is enabled, it displays the primary and secondary command-switch information.
If you enter this command on a switch that is not a cluster member, the error message Not a management cluster member appears.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output when this command is entered on the active command switch:
Command switch for cluster "Switch1"
Total number of members: 7
Status: 1 members are unreachable
Time since last status change: 0 days, 0 hours, 2 minutes
Standby command switch: Member 1
Standby Group: Switch1_standby
Standby Group Number: 110
Extended discovery hop count: 3
This is an example of output when this command is entered on a member switch:
Member switch for cluster "commander"
Management IP address: 192.192.192.192
Command switch mac address: 0000.0c07.ac14
This is an example of output when this command is entered on a member switch that is configured as the standby command switch:
Member switch for cluster "commander"
Member number: 3 (Standby command switch)
Management IP address: 192.192.192.192
Command switch mac address: 0000.0c07.ac14
This is an example of output when this command is entered on the command switch that has lost connectivity from member 1:
Command switch for cluster "Switch1"
Total number of members: 7
Status: 1 members are unreachable
Time since last status change: 0 days, 0 hours, 5 minutes
Extended discovery hop count: 3
This is an example of output when this command is entered on a member switch that has lost connectivity with the command switch:
Member switch for cluster "commander"
Management IP address: 192.192.192.192
Command switch mac address: 0000.0c07.ac14
Related Commands
Command
|
Description
|
cluster enable
|
Enables a command-capable switch as the cluster command switch, assigns a cluster name, and optionally assigns a member number to it.
|
show cluster candidates
|
Displays a list of candidate switches.
|
show cluster members
|
Displays information about the cluster members.
|
show cluster candidates
Use the show cluster candidates privileged EXEC command on the command switch to display a list of candidate switches.
show cluster candidates [detail | mac-address H.H.H.] [ | {begin | exclude | include} expression]
Syntax Description
detail
|
(Optional) Display detailed information for all candidates.
|
mac-address H.H.H.
|
(Optional) Hexadecimal MAC address of the cluster candidate.
|
| begin
|
(Optional) Display begins with the line that matches the specified expression.
|
| exclude
|
(Optional) Display excludes lines that match the specified expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
Privileged EXEC
Command History
Release
|
Modification
|
12.0(5.2)WC(1)
|
This command was introduced.
|
Usage Guidelines
You should only enter this command on a command switch.
If the switch is not a command switch, the command displays an empty line at the prompt.
The SN in the output means switch member number. If E is in the SN column, it means that the switch is discovered through extended discovery. If E does not appear in the SN column, it means that the switch member number is the upstream neighbor of the candidate switch. The hop count is the number of devices the candidate is from the command switch.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show cluster candidates command:
Switch# show cluster candidates
MAC Address Name Device Type PortIf FEC Hops SN PortIf FEC
0030.85f5.8e80 3550-12T WS-C3550-12T Gi0/4 1 0 Fa0/1
0005.313c.5880 Switch2 WS-C3550-12T Gi0/1 2 E Gi0/5
0005.dcc8.01c0 2950-145 WS-C2950T-24 Fa0/1 3 E Gi0/2
0002.b922.7180 C2820 WS-C2820-24 Fa0/3 Up
This is an example of output from the show cluster candidates command that uses the MAC address of a member switch directly connected to the command switch:
Switch# show cluster candidates mac-address 00d0.7961.c4c0
Device 'c2950-12' with mac address number 00d0.7961.c4c0
Device type: cisco WS-C2950-12
Upstream MAC address: 00d0.796d.2f00 (Cluster Member 0)
Local port: Fa0/3 FEC number:
Upstream port: Fa0/13 FEC Number:
Hops from cluster edge: 1
Hops from command device: 1
This is an example of output from the show cluster candidates command that uses the MAC address of a member switch three hops from the cluster edge:
Switch# show cluster candidates mac-address 0010.7bb6.1cc0
Device 'c2950-24' with mac address number 0010.7bb6.1cc0
Device type: cisco WS-C2950-24
Upstream MAC address: 0010.7bb6.1cd4
Local port: Fa2/1 FEC number:
Upstream port: Fa0/24 FEC Number:
Hops from cluster edge: 3
Hops from command device: -
This is an example of output from the show cluster candidates detail command:
Switch# show cluster candidates detail
Device 'c2950-12' with mac address number 00d0.7961.c4c0
Device type: cisco WS-C2950-12
Upstream MAC address: 00d0.796d.2f00 (Cluster Member 1)
Local port: Fa0/3 FEC number:
Upstream port: Fa0/13 FEC Number:
Hops from cluster edge: 1
Hops from command device: 2
Device '1900_Switch' with mac address number 00e0.1e7e.be80
Upstream MAC address: 00d0.796d.2f00 (Cluster Member 2)
Local port: 3 FEC number: 0
Upstream port: Fa0/11 FEC Number:
Hops from cluster edge: 1
Hops from command device: 2
Device 'c2924-XL' with mac address number 00e0.1e9f.7a00
Device type: cisco WS-C2924-XL
Upstream MAC address: 00d0.796d.2f00 (Cluster Member 3)
Local port: Fa0/5 FEC number:
Upstream port: Fa0/3 FEC Number:
Hops from cluster edge: 1
Hops from command device: 2
Related Commands
Command
|
Description
|
show cluster
|
Displays the cluster status and a summary of the cluster to which the switch belongs.
|
show cluster members
|
Displays information about the cluster members.
|
show cluster members
Use the show cluster members privileged EXEC command on the command switch to display information about the cluster members.
show cluster members [n | detail] [ | {begin | exclude | include} expression]
Syntax Description
n
|
(Optional) Number that identifies a cluster member. The range is 0 to 15.
|
detail
|
(Optional) Display detailed information for all cluster members.
|
| begin
|
(Optional) Display begins with the line that matches the specified expression.
|
| exclude
|
(Optional) Display excludes lines that match the specified expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
Privileged EXEC
Command History
Release
|
Modification
|
12.0(5.2)WC(1)
|
This command was introduced.
|
Usage Guidelines
You should only enter this command on a command switch.
If the cluster has no members, this command displays an empty line at the prompt.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show cluster members command. The SN in the display means switch number.
Switch# show cluster members
SN MAC Address Name PortIf FEC Hops SN PortIf FEC State
0 0002.4b29.2e00 StLouis1 0 Up (Cmdr)
1 0030.946c.d740 tal-switch-1 Fa0/13 1 0 Gi0/1 Up
2 0002.b922.7180 nms-2820 10 0 2 1 Fa0/18 Up
3 0002.4b29.4400 SanJuan2 Gi0/1 2 1 Fa0/11 Up
4 0002.4b28.c480 GenieTest Gi0/2 2 1 Fa0/9 Up
Switch# show cluster members
SN MAC Address Name PortIf FEC Hops SN PortIf FEC State
0 0404.0400.0001 Switch 0 Up
1 0003.fd62.9240 b10-2940TT Fa0/1 1 0 Gi0/20 Up
This is an example of output from the show cluster members 3 command for cluster member 3:
Switch# show cluster members 3
Device 'SanJuan2' with member number 3
Device type: cisco WS-C3550-12T
MAC address: 0002.4b29.4400
Upstream MAC address: 0030.946c.d740 (Cluster member 1)
Local port: Gi0/1 FEC number:
Upstream port: Fa0/11 FEC Number:
Hops from command device: 2
This is an example of output from the show cluster members detail command:
Switch# show cluster members detail
Device 'StLouis1' with member number 0 (Command Switch)
Device type: cisco WS-C3550-12T
MAC address: 0002.4b29.2e00
Upstream port: FEC Number:
Hops from command device: 0
Device 'tal-switch-14' with member number 1
Device type: cisco WS-C3548-XL
MAC address: 0030.946c.d740
Upstream MAC address: 0002.4b29.2e00 (Cluster member 0)
Local port: Fa0/13 FEC number:
Upstream port: Gi0/1 FEC Number:
Hops from command device: 1
Device 'nms-2820' with member number 2
MAC address: 0002.b922.7180
Upstream MAC address: 0030.946c.d740 (Cluster member 1)
Local port: 10 FEC number: 0
Upstream port: Fa0/18 FEC Number:
Hops from command device: 2
Device 'SanJuan2' with member number 3
Device type: cisco WS-C3550-12T
MAC address: 0002.4b29.4400
Upstream MAC address: 0030.946c.d740 (Cluster member 1)
Local port: Gi0/1 FEC number:
Upstream port: Fa0/11 FEC Number:
Hops from command device: 2
Device 'Test' with member number 4
Device type: cisco SeaHorse
MAC address: 0002.4b28.c480
Upstream MAC address: 0030.946c.d740 (Cluster member 1)
Local port: Gi0/2 FEC number:
Upstream port: Fa0/9 FEC Number:
Hops from command device: 2
Device 'Palpatine' with member number 5
Device type: cisco WS-C2924M-XL
MAC address: 00b0.6404.f8c0
Upstream MAC address: 0002.4b29.2e00 (Cluster member 0)
Local port: Gi2/1 FEC number:
Upstream port: Gi0/7 FEC Number:
Hops from command device: 1
Related Commands
Command
|
Description
|
show cluster
|
Displays the cluster status and a summary of the cluster to which the switch belongs.
|
show cluster candidates
|
Displays a list of candidate switches.
|
show controllers ethernet-controller
Use the show controllers ethernet-controller privileged EXEC command without keywords to display per-interface send and receive statistics read from the hardware. Use this command with keywords to display the interface internal registers or to display the statistics read from Long-Reach Ethernet (LRE) and customer premises equipment (CPE) ports.
show controllers ethernet-controller interface-id [asic | cpe [port port-id] | phy 32] [ | {begin |
exclude | include} expression]
Syntax Description
interface-id
|
ID of the switch interface.
|
asic
|
(Optional) Display the state of the internal registers on the forwarding application-specific integrated circuit (ASIC) for the interface. This keyword is available only on non-LRE switches.
|
cpe [port port-id]
|
(Optional) Display statistics from the LRE and Fast Ethernet ports on connected devices.
• port port-id—Display the Ethernet statistics of the designated CPE Ethernet port. The range is 1 to 4, depending on the CPE device.
These keywords are available only on LRE switches.
|
phy 32
|
(Optional) Display the status of the internal registers on the switch physical layer device (PHY) for the interface. This keyword is available only on non-LRE switches.
|
| begin
|
(Optional) Display begins with the line that matches the expression.
|
| exclude
|
(Optional) Display excludes lines that match the expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
Privileged EXEC (only supported with the interface-id keywords in user EXEC mode)
Command History
Release
|
Modification
|
12.1(6)EA2
|
This command was introduced.
|
12.1(11)YJ
|
The cpe and port port-id keywords were added.
|
12.1(19)EA1
|
The phy keyword was changed to phy 32.
|
Usage Guidelines
Use this command without keywords to display traffic statistics, particularly the RMON statistics for the interface. If this command is entered on a Catalyst 2950 LRE switch, the command output also shows the statistics for the LRE switch interfaces.
When you enter the asic or phy 32 keyword, the displayed information is primarily useful for Cisco technical support representatives troubleshooting the switch. When you enter the cpe keyword, the displayed information shows the traffic statistics for the connected CPE devices. The CPE Ethernet link on an LRE switch port is the connection between the Cisco LRE CPE and the remote Ethernet device (such as a PC) connected to it. It is not the link between the LRE switch port and the LRE CPE device.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show controllers ethernet-controller command on a non-LRE switch. For this example, Table 2-9 describes the Transmit fields, Table 2-10 describes the Receive fields, and Table 2-11 describes the Transmit and Receive fields.
Switch# show controllers ethernet-controller fastethernet0/2
19555003 Bytes 23485398 Bytes
222479 Frames 313530 Frames
161490 Multicast frames 0 FCS errors
256 Broadcast frames 313467 Multicast frames
0 Pause frames 1 Broadcast frames
0 Single defer frames 0 Control frames
0 Multiple defer frames 0 Pause frames
0 1 collision frames 0 Unknown opcode frames
0 2-15 collisions 0 Alignment errors
0 Late collisions 0 Length out of range
0 Excessive collisions 0 Symbol error frames
0 Total collisions 0 False carrier errors
0 Control frames 0 Valid frames, too small
0 VLAN discard frames 0 Valid frames, too large
0 Too old frames 0 Invalid frames, too small
0 Tagged frames 0 Invalid frames, too large
0 Aborted Tx frames 0 Discarded frames
384595 Minimum size frames
131178 65 to 127 byte frames
20229 256 to 511 byte frames
1 512 to 1023 byte frames
0 1024 to 1518 byte frames
0 1519 to 1522 byte frames
Table 2-9 Transmit Field Descriptions
Field
|
Description
|
Bytes
|
The total number of bytes sent on an interface.
|
Frames
|
The total number of frames sent on an interface.
|
Multicast frames
|
The total number of frames sent to multicast addresses.
|
Broadcast frames
|
The total number of frames sent to broadcast addresses.
|
Pause frames
|
The number of pause frames sent on an interface.
|
Single defer frames
|
The number of frames for which the first transmission attempt on an interface is not successful. This value excludes frames in collisions.
|
Multiple defer frames
|
The number of frames that are not sent after the time exceeds 2*maximum-packet time.
|
1 collision frames
|
The number of frames that are successfully sent on an interface after one collision occurs.
|
2-15 collisions
|
The number of frames that are successfully sent on an interface after more than one collision occurs.
|
Late collisions
|
After a frame is sent, the number of times that a collision is detected on an interface later than 512 bit times.
|
Excessive collisions
|
The number of frames that could not be sent on an interface because more than 16 collisions occurred.
|
Total collisions
|
The total number of collisions on an interface.
|
Control frames
|
The number of control frames sent on an interface, such as STP1 BPDUs2 .
|
VLAN discard frames
|
The number of frames dropped on an interface because the CFI3 bit is set.
|
Too old frames
|
The number of frames dropped on the egress port because the packet aged out.
|
Tagged frames
|
The number of tagged frames sent on an interface.
|
Aborted Tx frames
|
The number of aborted transmission attempts on the interface.
|
Table 2-10 Receive Field Descriptions
Field
|
Description
|
Bytes
|
The total amount of memory (in bytes) used by frames received on an interface, including the FCS1 value and the incorrectly formed frames. This value excludes the frame header bits.
|
Frames
|
The total number of frames received on an interface, including multicast frames, broadcast frames, and incorrectly formed frames.
|
FCS errors
|
The total number of frames received on an interface that have a valid length (in bytes) but do not have the correct FCS values.
|
Multicast frames
|
The total number of frames successfully received on the interface that are directed to multicast addresses.
|
Broadcast frames
|
The total number of frames successfully received on an interface that are directed to broadcast addresses.
|
Control frames
|
The number of control frames received on an interface, such as STP BPDUs.
|
Pause frames
|
The number of pause frames received on an interface.
|
Unknown opcode frames
|
The number of frames received with an unknown operation code.
|
Alignment errors
|
The total number of frames received on an interface that have alignment errors.
|
Length out of range
|
The number of frames received on an interface that have an out-of-range length.
|
Symbol error frames
|
The number of frames received on an interface that have symbol errors.
|
False carrier errors
|
The number of occurrences in which the interface detects a false carrier when frames are not sent or received.
|
Valid frames, too small
|
The number of frames received on an interface that are smaller than 64 bytes (or 68 bytes for VLAN-tagged frames) and have valid FCS values. The frame size includes the FCS bits but excludes the frame header bits.
|
Valid frames, too large
|
The number of frames received on an interface that are larger than the maximum allowed frame size.
|
Invalid frames, too small
|
The number of frames received that are smaller than 64 bytes (including the FCS bits and excluding the frame header) and that have either an FCS error or an alignment error.
|
Invalid frames, too large
|
The number of frames received that were larger than maximum allowed MTU2 size (including the FCS bits and excluding the frame header) and that have either an FCS error or an alignment error.
Note For information about the maximum allowed MTU size on the switch, see the system mtu global configuration command.
|
Discarded frames
|
The number of frames discarded because of lack of receive buffer memory.
|
Table 2-11 Transmit and Receive Field Descriptions
Field
|
Description
|
Minimum size frames
|
The total number of frames that are the minimum frame size.
|
65 to 127 byte frames
|
The total number of frames that are from 65 to 127 bytes.
|
128 to 255 byte frames
|
The total number of frames that are from 128 to 255 bytes.
|
256 to 511 byte frames
|
The total number of frames that are from 256 to 511 bytes.
|
512 to 1023 byte frames
|
The total number of frames that are from 512 to 1023 bytes.
|
1024 to 1518 byte frames
|
The total number of frames that are from 1024 to 1518 bytes.
|
1519 to 1522 byte frames
|
The total number of frames that are from 1519 to 1522 bytes.
|
This is an example of output from the show controllers ethernet-controller command on an LRE switch. For this example, Table 2-9 describes the Transmit fields, Table 2-10 describes the Receive fields, Table 2-11 describes the Transmit and Receive fields, and Table 2-12 describes the LRE Enet Stats on Switch fields.
Switch# show controllers ethernet-controller longreachethernet0/4
0 Multicast frames 0 FCS errors
0 Broadcast frames 0 Multicast frames
0 Pause frames 0 Broadcast frames
0 Single defer frames 0 Control frames
0 Multiple defer frames 0 Pause frames
0 1 collision frames 0 Unknown opcode frames
0 2-15 collisions 0 Alignment errors
0 Late collisions 0 Length out of range
0 Excessive collisions 0 Symbol error frames
0 Total collisions 0 False carrier errors
0 Control frames 0 Valid frames, too small
0 VLAN discard frames 0 Valid frames, too large
0 Too old frames 0 Invalid frames, too small
0 Tagged frames 0 Invalid frames, too large
0 Aborted Tx frames 0 Discarded frames
0 512 to 1023 byte frames
0 1024 to 1518 byte frames
0 1519 to 1522 byte frames
LRE Enet Stats on Switch:
0 Pause frames 0 Pause frames
0 1 collision frames 0 Alignment errors
0 Multiple collisions 0 Collisions and Runts
0 Late collisions 0 Oversize frames
0 Excessive collisions 0 FCS errors
Table 2-12 LRE Enet Stats on Switch Field Descriptions
Field
|
Description
|
Transmit
|
Bytes
|
The total number of bytes sent on an interface.
|
Frames
|
The total number of frames sent on an interface.
|
Pause frames
|
The number of pause frames sent on an interface.
|
1 collision frames
|
The number of frames that are successfully sent on an interface after one collision occurs.
|
Multiple collisions
|
The number of frames that are sent after more than one collision occurs.
|
Late collisions
|
After a frame is sent, the number of times that a collision is detected on an interface later than 512 bit times.
|
Excessive collisions
|
The number of frames that could not be sent on an interface because more than 16 collisions occurs.
|
Deferred frames
|
The number of frames that are not sent on an interface.
|
Carrier sense errors
|
The number of frames with carrier sense errors.
|
Receive
|
Bytes
|
The total amount of memory (in bytes) used by frames received on an interface, including the FCS value and the incorrectly formed frames. This value excludes the frame header bits.
|
Frames
|
The total number of frames received on an interface, including broadcast frames and incorrectly formed frames.
|
Broadcast frames
|
The total number of frames successfully received on an interface that are directed to broadcast addresses.
|
Pause frames
|
The number of pause frames received on an interface.
|
Alignment errors
|
The total number of frames received on an interface that have alignment errors.
|
Collisions and Runts
|
The number of frames that could not be received on an interface because of collisions because the frame length (in bytes) is too small.
|
Receive
|
Oversize frames
|
The total number of frames that are the larger than the maximum allowed frame size.
|
FCS errors
|
The total number of frames received on an interface that have a valid length (in bytes) but do not have the correct FCS values.
|
This is an example of output from the show controllers ethernet-controller longreachethernet0/4 cpe command. It shows the statistics of the LRE chipset and the all the LRE ports on the CPE. For this example, Table 2-13 describes the LRE Enet Stats on CPE fields, and Table 2-14 describes the CPE Fast Ethernet Port fields.
Switch# show controllers ethernet-controller longreachethernet0/4 cpe
0 Pause frames 0 Pause frames
0 1 collision frames 0 Alignment errors
0 Multiple collisions 0 Collisions and Runts
0 Late collisions 0 Oversize frames
0 Excessive collisions 0 FCS errors
CPE Fast Ethernet Port: 1
0 Unicast Frames 0 Unicast Frames
0 Multicast Frames 0 Multicast Frames
0 Broadcast Frames 0 Broadcast Frames
0 Dropped Frames 0 Dropped Frames
0 Pause Frames 0 Pause Frames
0 Collision Frames 0 Alignment Errors
0 One Collision Frames 0 Fragments
0 Multiple Collisions 0 Undersize Frames
0 Late Collisions 0 Oversize Frames
0 Excess Collisions 0 FCS errors
0 Frame Discard 0 Excess Size Discards
0 Deferred Frames 0 Jabbers
This is an example of output from the show controllers ethernet-controller longreachethernet0/4 cpe port 1 command. It shows the statistics for a specific LRE port on the CPE. For this example, Table 2-14 describes the CPE Fast Ethernet Port fields.
Switch# show controllers ethernet-controller longreachethernet0/4 cpe port 1
CPE Fast Ethernet Port: 1
42308326 Bytes 8264733 Bytes
193 Unicast Frames 68745 Unicast Frames
511408 Multicast Frames 11469 Multicast Frames
1886 Broadcast Frames 0 Broadcast Frames
0 Dropped Frames 0 Dropped Frames
0 Pause Frames 0 Pause Frames
0 Collision Frames 0 Alignment Errors
0 One Collision Frames 0 Fragments
0 Multiple Collisions 0 Undersize Frames
0 Late Collisions 0 Oversize Frames
0 Excess Collisions 0 FCS errors
0 Frame Discard 0 Excess Size Discards
2 Deferred Frames 0 Jabbers
11469 256-511 Byte Frames
Table 2-13 LRE Enet Stats on CPE Field Descriptions for LRE and CPE Interfaces
Field
|
Description
|
Transmit
|
Bytes
|
The total number of bytes sent on an interface.
|
Frames
|
The total number of frames sent on an interface.
|
Pause frames
|
The number of pause frames sent on an interface.
|
1 collision frames
|
The number of frames that are successfully sent on an interface after one collision occurs.
|
Multiple collisions
|
The number of frames that are sent after more than one collision occurs.
|
Late collisions
|
After a frame is sent, the number of times that a collision is detected on an interface later than 512 bit times.
|
Excessive collisions
|
The number of frames that could not be sent on an interface because more than 16 collisions occurs.
|
Deferred frames
|
The number of frames for which the first transmission attempt on an interface is not successful. This value excludes frames in collisions.
|
Carrier sense errors
|
The number of frames with carrier sense errors.
|
Receive
|
Bytes
|
The total amount of memory (in bytes) used by frames received on an interface, including the FCS value and the incorrectly formed frames. This value excludes the frame header bits.
|
Frames
|
The total number of frames received on an interface, including multicast frames, broadcast frames, and incorrectly formed frames.
|
Receive
|
Broadcast frames
|
The total number of frames successfully received on an interface that are directed to broadcast addresses.
|
Pause frames
|
The number of pause frames received on an interface.
|
Alignment errors
|
The total number of frames received on an interface that have alignment errors.
|
Collisions and Runts
|
The number of frames that could not be received on an interface because of collisions because the frame length (in bytes) is too small.
|
Oversize frames
|
The total number of frames that are the larger than the maximum frame size.
|
FCS errors
|
The total number of frames received on an interface that have a valid length (in bytes) but do not have the correct FCS values.
|
Table 2-14 CPE Fast Ethernet Port Field Descriptions for LRE and CPE Interfaces
Field
|
Description
|
Transmit
|
Bytes
|
The total number of bytes sent on an interface.
|
Unicast Frames
|
The total number of frames sent to unicast addresses.
|
Multicast Frames
|
The total number of frames sent to multicast addresses.
|
Broadcast Frames
|
The total number of frames sent to broadcast addresses.
|
Dropped Frames
|
The total number of frames that are not sent.
|
Pause Frames
|
The number of pause frames sent on an interface.
|
Collisions Frames
|
The total number of frames that are not sent on an interface because of collisions.
|
One Collision Frames
|
The number of frames that are successfully sent on an interface after one collision occurs.
|
Multiple Collisions
|
The number of frames that are sent after more than one collision occurs.
|
Late Collisions
|
After a frame is sent, the number of times that a collision is detected on an interface later than 512 bit times.
|
Excessive Collisions
|
The number of frames that could not be sent on an interface because more than 16 collisions occurs.
|
Deferred Frames
|
The number of frames for which the first transmission attempt on an interface is not successful. This value excludes frames in collisions.
|
Receive
|
Bytes
|
The total amount of memory (in bytes) used by frames received on an interface, including the FCS value and the incorrectly formed frames. This value excludes the frame header bits.
|
Good Bytes
|
The total amount of memory (in bytes) used by frames received on an interface, including the FCS value and the correctly formed frames. This value excludes the frame header bits.
|
Unicast Frames
|
The total number of frames successfully received on an interface that are directed to unicast addresses.
|
Multicast Frames
|
The total number of frames successfully received on an interface that are directed to multicast addresses.
|
Broadcast Frames
|
The total number of frames successfully received on an interface that are directed to broadcast addresses.
|
Dropped Frames
|
The total number of frames successfully received on an interface that are dropped.
|
Pause Frames
|
The number of pause frames received on an interface.
|
Alignment Errors
|
The total number of frames received on an interface that have alignment errors.
|
Fragments
|
The number of frames received on the interface that are smaller than 64 bytes and an invalid FCS value.
|
Undersize Frames
|
The total number of frames received on an interface that are smaller than 64 bytes.
|
Oversize Frames
|
The total number of frames received on an interface that are the larger than 1518 bytes.
|
FCS Errors
|
The total number of frames received on an interface that have a valid length (in bytes) but do not have the correct FCS values.
|
Excess Size Discards
|
The total number of frames received on an interface that are dropped because they are larger than 1518 bytes.
|
Jabbers
|
The total number of frames received on an interface that are larger than 1522 bytes and have either an FCS or alignment error.
|
Source Address Chang
|
The total number of frames received on an interface for which the source address changed.
|
Symbol Errors
|
The total number of frames received on an interface that have a valid length (in bytes) but have the symbol errors.
|
65 to 127 byte Frames
|
The total number of frames that are from 65 to 127 bytes.
|
128 to 255 byte Frames
|
The total number of frames that are from 128 to 255 bytes.
|
256 to 511 byte Frames
|
The total number of frames that are from 256 to 511 bytes.
|
512 to 1023 byte Frames
|
The total number of frames that are from 512 to 1023 bytes.
|
1024 to 1518 byte Frames
|
The total number of frames that are from 1024 to 1518 bytes.
|
1519 to 1522 byte Frames
|
The total number of frames that are from 1519 to 1522 bytes.
|
Related Commands
Command
|
Description
|
clear controllers ethernet-controller
|
Deletes the Ethernet link send and receive statistics on a Fast Ethernet or an LRE switch port on an LRE switch.
|
show interfaces
|
Displays the administrative and operational status of all interfaces or a specified interface.
|
show controllers lre cpe
Use the show controllers lre cpe privileged EXEC command to display information about the Cisco Long-Reach Ethernet (LRE) customer premises equipment (CPE) devices connected to an LRE switch.
show controllers lre cpe {identity | mfg | protected | version}[interface-id] [ | {begin | exclude |
include} expression]
This command is available only on Catalyst 2950 LRE switches.
Syntax Description
identity
|
Display the model numbers of the LRE CPE devices connected to an LRE switch and whether or not the connected CPE devices meet the minimum requirements for management by the LRE switch.
|
mfg
|
Display the revision and serial numbers of the connected LRE CPE board, assembly, and system.
|
protected
|
Display Cisco 585 LRE CPE Ethernet ports that are configured as protected.
|
version
|
Display the version numbers of the various components (hardware, firmware, patch software, and bootloader firmware and application firmware) of the LRE CPE interfaces.
|
interface-id
|
(Optional) ID of the LRE switch port.
|
| begin
|
(Optional) Display begins with the line that matches the specified expression.
|
| exclude
|
(Optional) Display excludes lines that match the specified expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
Privileged EXEC
Command History
Release
|
Modification
|
12.1(11)YJ
|
This command was introduced.
|
Usage Guidelines
The show controllers lre cpe identity privileged EXEC command output shows the type of CPE device attached to each LRE interface. For all Cisco supported CPE devices, the status can be certified, non-certified, or NA:
•
A certified status means that the CPE device meets the minimum requirements (such as having a certain CPE device patch version) for management by the LRE switch.
•
A non-certified status means that the CPE device did not meet the minimum requirements. If a CPE device shows a status of non-certified or if the family is not a Cisco 585 LRE CPE, Cisco 576 LRE 997 CPE, or a Cisco 575 LRE CPE, use the show controllers lre cpe mfg privileged EXEC command to verify the CPE manufacturing fields.
•
An NA status means that there is not a link or there is not any information about that port.
Use the show controllers lre cpe identity privileged EXEC command without specifying an LRE switch port to display the model numbers and status of all connected CPE devices.
Use the show controllers lre cpe mfg privileged EXEC command output to display fields specific to each CPE device unit. The software uses the model number field to identify the kind of CPE device attached to an LRE interface. The System Serial Number is also unique to each CPE device unit.
Use the show controllers lre cpe protected privileged EXEC command without specifying an LRE interface to display the protected port setting for all CPE ports. The Cisco 575 LRE CPE or Cisco 576 LRE 997 CPE devices display a protected field output of NA.
Use the show controllers lre cpe version privileged EXEC command without specifying an LRE switch port to display the version numbers of all CPE interfaces.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show controllers lre cpe identity command for the Cisco 575 LRE and Cisco 585 LRE CPE devices:
Switch# show controllers lre cpe identity
Port CPE Model Status Family
------ ------------ --------------- ------
Lo0/1 CISCO585-LRE CERTIFIED CISCO585-LRE
Lo0/2 CISCO585-LRE CERTIFIED CISCO585-LRE
Lo0/3 CISCO585-LRE CERTIFIED CISCO585-LRE
Lo0/6 Cisco575-LRE CERTIFIED CISCO575-LRE
Lo0/8 Cisco575-LRE CERTIFIED CISCO575-LRE
Lo0/11 CISCO585-LRE CERTIFIED CISCO585-LRE
Lo0/12 CISCO585-LRE CERTIFIED CISCO585-LRE
Lo0/13 CISCO585-LRE CERTIFIED CISCO585-LRE
Lo0/14 NON-CERTIFIED UNSUPPORTED-MAC-MODE
This is an example of output from the show controllers lre cpe mfg command that shows the manufacturing information for the Cisco 575 LRE and Cisco 585 CPE devices:
Switch# show controllers lre cpe mfg
CPE Manufacturer Information:
Assembly Revision Number:
Model Number :CISCO585-LRE
Model Revision Number :A0
System Serial Number :ACT0613004E
Assembly Revision Number:
Model Number :CISCO585-LRE
Model Revision Number :A0
System Serial Number :ACT0613005B
This is an example of output from the show controllers lre cpe protected command that shows the CPE protected-port information for an LRE interface:
Switch# show controllers lre cpe protected longreachethernet0/9
This is an example of output from the show controllers lre cpe protected command that shows the CPE protected-port information for all LRE interfaces:
Switch# show controllers lre cpe protected
This is an example of output from the show controllers lre cpe version command:
Switch# show controllers lre cpe version longreachethernet0/5
Interface Hw Sw Patch Boot App
--------- --- --- ------ ----- -----
Related Commands
Command
|
Description
|
cpe protected
|
Restricts data traffic to individual ports on Cisco 585 LRE CPE ports.
|
show controllers lre version
|
Displays the version number of the hardware, software, and patch software components of the switch LRE interface and the CPE LRE interface.
|
show controllers lre actual
Use the show controllers lre actual privileged EXEC command to display the actual values of the Long-Reach Ethernet (LRE) link on a specific LRE switch port.
show controllers lre interface-id actual {dsrserrs | link | rxpower | snr | txpower | usrserrs}
[ | {begin | exclude | include} expression]
This command is available only on Catalyst 2950 LRE switches.
Syntax Description
interface-id
|
ID of the switch LRE port.
|
actual
|
Display the LRE port current status, which might not be the same as the administratively configured settings.
|
dsrserrs
|
Display the downstream Reed-Solomon errors on the LRE port.
|
usrserrs
|
Display the upstream Reed-Solomon errors on the LRE port.
|
txpower
|
Display the remote transmit power (dBm/Hz) on the LRE port.
|
rxpower
|
Display the local receive power (dBm/Hz) on the customer premises equipment (CPE) port.
|
snr
|
Display the signal-to-noise ratio (SNR) ratio on the LRE port.
|
link
|
Display the LRE link status of the LRE port.
|
| begin
|
(Optional) Display begins with the line that matches the specified expression.
|
| exclude
|
(Optional) Display excludes lines that match the specified expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
Privileged EXEC
Command History
Release
|
Modification
|
12.1(11)YJ
|
This command was introduced.
|
Usage Guidelines
You can use the SNR and Reed-Solomon error information to measure the quality of the LRE link. The SNR is the amount of increased received signal-power (in decibels) relative to the noise-power level that the switch can tolerate without disconnecting from the CPE device. The higher the ratio, the more resilient is the link.
The Reed-Solomon errors show the number of errors detected and corrected in the data being received on and sent from the switch LRE ports. Reed-Solomon errors are the result of noise exceeding the noise margin. For short bursts of noise (such as motor power on or power surges), the interleave feature prevents the loss of Ethernet data packets. Then the number of Reed-Solomon errors exceeds the number of Ethernet CRC errors.
The remote transmit power-rates from the connected CPE devices might be different from each other, depending on how long the cable is between the switch and the CPE device. A longer cable typically causes the CPE device to send a higher signal to overcome the loss effects of distance.
The local receive-power actually displays the switch's adjustment to the incoming power level. These numbers might be different from LRE port to LRE port, as the length of the cables to the CPE devices might be different.
If the SNR is too low for the environment but the link still establishes, the Reed-Solomon error rate is high, and there might be link instability (as shown by the number of Fail events counted). If the network is being used for data only, a high incidence of Ethernet Frame Check Sequence (FCS) errors or micro-interruptions might be tolerable.
For more information about what can affect the LRE link and for the minimum required SNR ratios, see the "LRE Links and LRE Profiles" section in the "Configuring LRE" chapter of the switch software configuration guide for this release.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show controllers lre interface-id actual dsrserrs command on an LRE port:
Switch# show controllers lre longreachethernet0/2 actual dsrserrs
This is an example of output from the show controllers lre interface-id actual link command on an LRE port:
Switch# show controllers lre longreachethernet0/2 actual link
This is an example of output from the show controllers lre interface-id actual rxpower command on an LRE port:
Switch# show controllers lre longreachethernet0/2 actual rxpower
This is an example of output from the show controllers lre interface-id actual snr command on an LRE port:
Switch# show controllers lre longreachethernet0/2 actual snr
This is an example of output from the show controllers lre interface-id actual txpower command on an LRE port:
Switch# show controllers lre longreachethernet0/2 actual txpower
This is an example of output from the show controllers lre interface-id actual usrserrs command on an LRE port:
Switch# show controllers lre longreachethernet0/2 actual usrserrs
This is an example of output from the show controllers lre interface-id actual link command on an LRE port:
Switch# show controllers lre longreachethernet0/1 actual link
Related Commands
Command
|
Description
|
show controllers lre admin
|
Displays the administrative settings of the LRE link on a specific switch LRE port.
|
show controllers lre admin
Use the show controllers lre interface-id admin privileged EXEC command to display the administrative settings of the Long-Reach Ethernet (LRE) link for a specific switch LRE port.
show controllers lre interface-id admin {dsrate | usrate}[ |{begin | exclude | include} expression]
This command is available only on Catalyst 2950 LRE switches.
Syntax Description
interface-id
|
ID of the switch LRE port.
|
admin
|
Display the administrative settings, which might not be the same as the actual values.
|
dsrate
|
Display the downstream rate (in Mbps) of the LRE link.
|
usrate
|
Display the upstream rate (in Mbps) of the LRE link.
|
| begin
|
(Optional) Display begins with the line that matches the specified expression.
|
| exclude
|
(Optional) Display excludes lines that match the specified expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
Privileged EXEC
Command History
Release
|
Modification
|
12.1(11)YJ
|
This command was introduced.
|
Usage Guidelines
This command displays the profile settings of an LRE switch port, even though they might not be active if a global profile is configured on the switch.
The upstream and downstream rates are defined by the profile on the switch LRE port. To change these rates, assign a different profile to the switch LRE port. For information about the LRE profiles, see the switch software configuration guide for this release.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show controllers lre interface-id admin dsrate and show controllers lre interface-id admin usrate commands:
Switch# show controllers lre longreachethernet0/1 admin usrate
Switch# show controllers lre longreachethernet0/1 admin dsrate
Switch# show controllers lre longreachethernet0/2 admin usrate
Switch# show controllers lre longreachethernet0/2 admin dsrate
Related Commands
show controllers lre link monitor
Use the show controllers lre link monitor privileged EXEC command to display Long-Reach Ethernet (LRE) link monitor information.
show controllers lre monitor {errors | parameters | statistics} {local [interface-id] | remote
[interface-id]} [ | {begin | exclude | include} expression]
This command is available only on Catalyst 2950 LRE switches.
Syntax Description
errors
|
Display the LRE Reed-Solomon (RS) errors and Ethernet errors
|
parameters
|
Display the LRE operating parameter data collected by the link monitor.
|
statistics
|
Display the LRE link monitor statistics.
|
local
|
(Optional) Display data from the LRE switch controller.
|
remote
|
(Optional) Display data from the customer premises equipment (CPE) device.
|
interface-id
|
(Optional) ID of the switch LRE port.
|
| begin
|
(Optional) Display begins with the line that matches the specified expression.
|
| exclude
|
(Optional) Display excludes lines that match the specified expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
Privileged EXEC
Command History
Release
|
Modification
|
12.1(11)YJ
|
This command was introduced.
|
Usage Guidelines
The link monitor process collects error information at 1-minute intervals for 15 minutes. After 15 minutes, the data is analyzed and stored before starting a new collection sequence. Up to 2 hours of link monitor data can be shown.
Local monitoring collects data from the LRE switch. Remote monitoring collects data from attached CPE device.
The Time heading in the show controllers lre link monitor errors command output shows the timestamp for the last collection sequence. The RS error count shows the cumulative error count from the last reading. Alignment errors, frame check sequence (FCS) errors, receive errors, and oversize errors are the Ethernet statistics collected either at the switch or at the CPE device.
The Time heading in the show controllers lre link monitor parameters command output shows the timestamp for the last collection sequence. The signal-to-noise (SNR) error counter, shown under the SNR Err heading, increments when the SNR value read from the chipset falls below the theoretical SNR added to the threshold.
The Time heading in the show controllers lre link monitor statistics command output shows the timestamp for the last collection sequence. The RS error count shows the cumulative error count from the last reading. This count is cleared only when the interface is shut down or when the clear controllers lre link monitor privileged EXEC command is entered. The RS error alarm shows the number of 1 minute intervals that had RS errors above the configured threshold.
Use the show controllers lre monitor {errors | parameters | statistics} privileged EXEC command without specifying a switch interface to display data for all interfaces.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output that shows how to display LRE RS and Ethernet errors for the LRE switch on an LRE port:
Switch# show controllers lre link monitor errors local longreachethernet0/1
LongReachEthernet0/1:LRE Link Health Monitor Error counts :
Time RS Errors Align Errs FCS Errs Rcv Errs Oversz Errs
-------- ---------- ---------- ---------- ---------- -----------
This is an example of output that shows Reed-Solomon and Ethernet errors for a CPE device connected to an LRE port:
Switch# show controllers lre link monitor errors remote longreachethernet0/1
LongReachEthernet0/1:LRE Link Health Monitor Error counts :
Time RS Errors Align Errs FCS Errs Rcv Errs Oversz Errs
-------- ---------- ---------- ---------- ---------- -----------
14:42:28 6400 45835 0 0 0
14:30:28 6400 45835 0 0 0
14:15:28 6400 45835 0 0 0
14:00:29 6400 45835 0 0 0
13:45:28 6144 45835 0 0 0
13:30:29 6144 45835 0 0 0
13:15:29 6144 45835 0 0 0
13:00:28 6144 45835 0 0 0
This is an example that shows how to display all LRE link monitor parameters for the attached CPE device:
Switch# show controllers lre link monitor parameters remote
LongReachEthernet0/1: LRE Link Health Monitor Parameters :
Time Samples Min Max Err Min Max Min Max
-------- ------- --- --- --- ------- ------- ------- -------
00:32:30 2 0 0 0 - 85.6 - 85.6 - 2.0 - 2.0
00:30:30 15 0 0 0 - 85.6 - 85.6 - 2.0 - 2.0
00:15:30 15 0 0 0 - 85.6 - 85.6 - 2.0 - 2.0
00:00:30 15 0 0 0 - 85.6 - 85.6 - 2.0 - 2.0
23:45:30 15 0 0 0 - 85.6 - 85.6 - 2.0 - 2.0
23:30:30 15 0 0 0 - 85.6 - 85.6 - 2.0 - 2.0
23:15:30 15 0 0 0 - 85.6 - 85.6 - 2.0 - 2.0
This is an example that shows how to display all LRE link monitor statistics for the LRE controller:
Switch# show controllers lre link monitor statistics local
LongReachEthernet0/1: LRE Link Health Monitor Stats :
RS Errors Link Fail Freeze
Time Samples Count Alarm Count Count
-------- ------- --------------- ---------- ----------
Related Commands
show controllers lre log
Use the show controllers lre log user EXEC command without keywords to display the history of link, configuration, and timer events for a specific Long-Reach Ethernet (LRE) port or for all switch LRE ports. Use this command with keywords to display information about the LRE event log level.
show controllers lre log [level] [interface-id] [ | {begin | exclude | include} expression]
This command is available only on Catalyst 2950 LRE switches.
Syntax Description
level
|
(Optional) Display information about the LRE event log level.
|
interface-id
|
(Optional) ID of the switch LRE port.
|
| begin
|
(Optional) Display begins with the line that matches the specified expression.
|
| exclude
|
(Optional) Display excludes lines that match the specified expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
User EXEC
Command History
Release
|
Modification
|
12.1(11)YJ
|
This command was introduced.
|
Usage Guidelines
Use the show controllers lre log command without specifying a switch LRE port to display the events for all LRE switch ports. The time-stamped and sequentially tagged log entries can be helpful in confirming LRE link drops and configuration changes.
Use the show controllers lre log level command without specifying an LRE switch port to list the log level for each LRE port on the switch.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show controllers lre log command that shows events on an LRE interface:
Switch> show controllers lre log longreachethernet0/5
LongReachEthernet0/5: Events Log: ==================================
1d00h: [0]: State RESTART: Got event:Reset
1d00h: [1]: State MODEZERO_APPLIED: Got event:Link Up
1d00h: [2]: State MODEZERO_APPLIED: Got event:Link Down
1d00h: [3]: State PROFILE_APPLIED: Got event:Link Up
1d00h: [4]: State PROFILE_LINKUP: Got event:Link Down
1d00h: [5]: State PROFILE_LINKUP: Got event:Link Up
1d00h: [6]: State PROFILE_LINKUP: Got event:Link Down
1d00h: [7]: State PROFILE_LINKUP: Got event:Link Up
This is an example of output from the show controllers lre log level command that displays the log level on an LRE port:
Switch> show controllers lre log level longreachethernet0/1
Related Commands
show controllers lre profile
Use the show controllers lre profile privileged EXEC command to display information about the Long-Reach Ethernet (LRE) profiles and sequences available on the switch.
show controllers lre profile {details | names} [ | {begin | exclude | include} expression]
This command is available only on Catalyst 2950 LRE switches.
Syntax Description
details
|
Display information about the LRE profiles and sequences available on the switch.
|
names
|
Display information about the Long-Reach Ethernet (LRE) profiles available on the switch.
|
| begin
|
(Optional) Display begins with the line that matches the expression.
|
| exclude
|
(Optional) Display excludes lines that match the expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
Privileged EXEC
Command History
Release
|
Modification
|
12.1(11)YJ
|
This command was introduced.
|
Usage Guidelines
Use the show controllers lre profile details privileged EXEC command to see the profiles and sequences running on each port. This command also shows global profiles and sequences.
For information about LRE profiles supported on your switch and about LRE links, see the "LRE Profiles" section in the "Configuring LRE" chapter of the switch software configuration guide for this release.
Note
Use the information in the software configuration guide only as a guideline. Factors such as the type of cable that you use, how it is bundled, and the interference and noise on the LRE link can affect the actual LRE link performance. Contact Cisco Systems for information about limitations and optimization of LRE link performance. The net data rates are slightly less than the gross data rates displayed by the show controllers lre profile names command output.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show controllers lre profile details command on the Catalyst 2950ST-8 LRE and 2950ST-24 LRE switches:
Switch# show controllers lre profile details
Interface Configured Profile Running Profile Type
--------- ------------------ --------------- ------
Lo0/1 LRE-10-5 LRE-15 Port Sequence
Lo0/2 LRE-10-3 LRE-10-3 Global Profile
Lo0/3 LRE-10-3 LRE-15 Port Sequence
Lo0/4 LRE-10-3 LRE-10-3 Global Profile
Lo0/5 LRE-10-3 LRE-10-3 Global Profile
Lo0/6 LRE-10-3 LRE-10-3 Global Profile
Lo0/7 LRE-10-3 LRE-15 Global Profile
Lo0/8 LRE-10-3 LRE-10-3 Global Profile
Lo0/9 LRE-10-3 LRE-10-3 Global Profile
Lo0/10 LRE-10-3 LRE-10-3 Global Profile
Lo0/11 LRE-10-3 LRE-10-3 Global Profile
Lo0/12 LRE-10-3 LRE-10-3 Global Profile
This is an example of output from the show controllers lre profile details command on the Catalyst 2950ST-24 LRE 997 switch:
Switch# show controllers lre profile details
Interface Configured Profile Running Profile Type
--------- ------------------ --------------- ------
Lo0/1 LRE-6 LRE-6 Global Profile
Lo0/2 LRE-6 LRE-6 Global Profile
Lo0/3 LRE-6 LRE-6 Global Profile
Lo0/4 LRE-6 LRE-6 Global Profile
Lo0/5 LRE-6 LRE-6 Global Profile
Lo0/6 LRE-6 LRE-6 Global Profile
Lo0/7 LRE-6 LRE-6 Global Profile
Lo0/8 LRE-6 LRE-6 Global Profile
Lo0/9 LRE-6 LRE-6 Global Profile
Lo0/10 LRE-6 LRE-6 Global Profile
Lo0/11 LRE-6 LRE-6 Global Profile
Lo0/12 LRE-6 LRE-6 Global Profile
This is an example of output from the show controllers lre profile names command on the Catalyst 2950ST-8 LRE and 2950ST-24 LRE switches:
Switch# show controllers lre profile names
Profile Name Type Downstream Upstream
------------ ----------------- ---------- ----------
LRE-15 System-Configured 16.667 18.750
LRE-10 System-Configured 12.500 12.500
LRE-5 System-Configured 6.250 6.250
LRE-998-15-4 System-Configured 16.667 4.688
LRE-997-10-4 System-Configured 12.500 4.688
LRE-15LL System-Configured 16.667 18.750
LRE-10LL System-Configured 12.500 12.500
LRE-5LL System-Configured 6.250 6.250
LRE-10-5 System-Configured 12.500 6.250
LRE-10-3 System-Configured 12.500 3.125
LRE-10-1 System-Configured 12.500 1.563
LRE-8 System-Configured 9.375 9.375
LRE-7 System-Configured 8.333 8.333
LRE-15-5 System-Configured 16.667 6.250
LRE-15-3 System-Configured 16.667 3.125
LRE-15-1 System-Configured 16.667 1.563
LRE-4 System-Configured 4.167 4.167
LRE-3 System-Configured 3.125 3.125
LRE-2 System-Configured 2.083 2.083
LRE-4-1LL System-Configured 4.167 1.563
This is an example of output from the show controllers lre profile names command on the Catalyst 2950ST-24 LRE 997 switch:
Switch# show controllers lre profile names
Profile Name Type Downstream Upstream
------------ ----------------- ---------- ----------
LRE-12-9 System-Configured 12.500 9.375
LRE-12-3 System-Configured 12.500 3.125
LRE-9 System-Configured 9.375 9.375
LRE-9-6 System-Configured 9.375 6.250
LRE-9-4 System-Configured 9.375 4.688
LRE-9-3 System-Configured 9.375 3.125
LRE-6 System-Configured 6.250 6.250
LRE-6-4 System-Configured 6.250 4.688
LRE-6-3 System-Configured 6.250 3.125
LRE-4 System-Configured 4.688 4.688
Related Commands
Command
|
Description
|
lre profile
|
Assigns an LRE profile to all the LRE ports on the switch.
|
show controllers lre sequence
Use the show controllers lre sequence privileged EXEC command to display the list of sequences, the profiles that are configured in that sequence, and the downstream and upstream rates of the corresponding profiles.
show controllers lre sequence [ | {begin | exclude | include} expression]
This command is available only on Catalyst 2950 LRE switches.
Syntax Description
| begin
|
(Optional) Display begins with the line that matches the expression.
|
| exclude
|
(Optional) Display excludes lines that match the expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
Privileged EXEC
Command History
Release
|
Modification
|
12.1(11)YJ
|
This command was introduced.
|
Usage Guidelines
Use the show controllers lre sequence command to display the list of sequences supported in the switch. This command displays the system-defined and user-defined sequences.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show controllers lre sequence command on the Catalyst 2950ST-8 LRE and 2950ST-24 LRE switches:
Switch# show controllers lre sequence
Global Sequence:LRE-SEQ-COMPLETE-REACH
Sequence:LRE-SEQ-COMPLETE-REACH Type:System-Configured
Profile Name Downstream Upstream
-------------- ---------- ----------
Sequence:LRE-SEQ-DOWNSTREAM Type:System-Configured
Profile Name Downstream Upstream
-------------- ---------- ----------
This is an example of output from the show controllers lre sequence command on the Catalyst 2950ST-24 LRE 997 switch:
Switch# show controllers lre sequence
Sequence:LRE-SEQ-COMPLETE-REACH Type:System-Configured
Profile Name Downstream Upstream
-------------- ---------- ----------
Sequence:LRE-SEQ-DOWNSTREAM Type:System-Configured
Profile Name Downstream Upstream
-------------- ---------- ----------
Related Commands
show controllers lre status
Use the show controllers lre status privileged EXEC command to display the Long-Reach Ethernet (LRE) link statistics and profile information on a switch LRE port, including link state, link duration, profile name, and data rates.
show controllers lre status {cpe | interleave | link | profile | psd | sequence [detail]} [interface-id]
[ | {begin | exclude | include} expression]
This command is available only on Catalyst 2950 LRE switches.
Syntax Description
cpe
|
Display information about the customer premises equipment (CPE) 10/100 Ethernet ports.
|
interleave
|
Display the interleave block size values on the LRE interfaces.
|
link
|
Display the various parameters and status associated with the LRE link.
|
profile
|
Display the various administrative parameters and status associated with the LRE link.
|
psd
|
Display the power-related status.
|
sequence
|
Display the status of profiles in a sequence. Possible status values are converged, waiting on link, executing, and locked.
|
detail
|
(Optional) Display additional information about the sequences, such as margins, locked profiles, and convergence times.
|
interface-id
|
(Optional) ID of the switch LRE port.
|
| exclude
|
(Optional) Display excludes lines that match the specified expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
Privileged EXEC
Command History
Release
|
Modification
|
12.1(11)YJ
|
This command was introduced.
|
12.1(11)YJ4
|
The interleave keyword was added.
|
12.1(14)EA1
|
The cpe keyword was added.
|
Usage Guidelines
Use the show controllers lre status privileged EXEC command to display the status of all switch LRE ports.
Use the signal-to-noise ratio (SNR) and Reed-Solomon error information to measure the quality of the LRE link. The SNR represents the amount of increased received signal power (in decibels) relative to the noise power-level that the switch can tolerate without disconnecting from the CPE device. The higher the ratio, the more resilient is the link.
The Reed-Solomon errors show the number of errors detected and corrected in the data being received on and sent from the switch LRE ports. Reed-Solomon errors are the result of noise exceeding the noise margin. For short bursts of noise (such as motor power on or power surges), the interleaver prevents the loss of Ethernet data packets. The number of Reed-Solomon errors then exceeds the number of Ethernet CRC errors.
Note
The Reed-Solomon errors are reset each time that you enter the show controllers lre status link command.
The remote transmit power levels from the connected CPE devices might be different from each other, depending on how long the cable is between the switch and the CPE device. A longer cable typically causes the CPE device to send a higher signal to overcome the loss effects of distance.
The local receive-power rates actually displays the switch's adjustment to the incoming power level. These numbers might be different from LRE port to LRE port, as the length of the cables to the CPE devices might be different.
The interleaver columns display the interleaver block size for both directions of data. A higher interleaver setting is less susceptible to certain kinds of impairments but can introduce a very small amount of delay in the data path.
The PMD-S column refers to physical media dependent status and is provided as diagnostic information.
For more information about what can affect the LRE link and for the minimum required SNR ratios, see the "LRE Links and LRE Profiles" section in the "Configuring LRE" chapter of the switch software configuration guide for this release.
The sequence and sequence detail keywords display these status codes of profiles and sequences during rate selection:
•
Converged—Rate selection has converged on a profile.
•
Locked—Rate selection has converged on a profile, and the port is locked to that profile.
•
Executing—Rate selection is running on the port.
•
Waiting on Link—No link is established.
•
N/A—Sequence is not assigned to the port.
You can adjust the noise level during convergence by using the margin interface configuration command.
Use the show controllers lre status cpe [interface-id] privileged EXEC command to display information about a specific CPE port or all the CPE ports.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output that shows link information for an LRE interface:
Switch# show controller lre status link longreachethernet0/2
Port Link SNR RS Errs CPE-Tx Sw-AGC-Gain Interleaver PMD-S
(dB) (dBm/Hz) (dB) Rx-Bsz Tx-Bsz
------ ---- ---- ----------- -------- ----------- ------------- -----
Lo0/2 UP 41 4829 - 57.7 - 7.6 16 16 0x04
This is an example of output from the show controllers lre status profile command:
Switch# show controllers lre status profile
Port Link Uptime Profile DSRate USRate Fail
------ ---- -------- ------------------- ------ ------ ----
Lo0/1 UP 2d23h LRE-10 12.500 12.500 0
Lo0/2 UP 2d23h LRE-10 4.167 1.563 0
Lo0/3 UP 2d23h LRE-10 4.167 1.563 0
Lo0/4 UP 2d23h LRE-10 4.167 1.563 0
Lo0/5 DOWN 00:00:00 LRE-10 0.000 0.000 0
Lo0/6 UP 2d23h LRE-10 4.167 1.563 0
Lo0/7 UP 2d23h LRE-10 4.167 1.563 0
Lo0/8 UP 2d23h LRE-10 4.167 1.563 0
Lo0/9 UP 2d23h LRE-10 4.167 1.563 0
Lo0/10 DOWN 00:00:00 LRE-10 0.000 0.000 0
Lo0/11 DOWN 00:00:00 LRE-10 0.000 0.000 0
Lo0/12 DOWN 00:00:00 LRE-10 0.000 0.000 0
Lo0/13 UP 2d23h LRE-10 12.500 12.500 0
Lo0/14 DOWN 00:00:00 LRE-10 0.000 0.000 0
Lo0/15 UP 2d23h LRE-10 4.167 1.563 0
Lo0/16 DOWN 00:00:00 LRE-10 0.000 0.000 0
Lo0/17 DOWN 00:00:00 LRE-10 0.000 0.000 0
Lo0/18 DOWN 00:00:00 LRE-10 0.000 0.000 0
Lo0/19 DOWN 00:00:00 LRE-10 0.000 0.000 0
Lo0/20 DOWN 00:00:00 LRE-10 0.000 0.000 0
Lo0/21 UP 2d23h LRE-10 4.167 1.563 0
Lo0/22 DOWN 00:00:00 LRE-10 0.000 0.000 0
Lo0/23 DOWN 00:00:00 LRE-10 0.000 0.000 0
Lo0/24 DOWN 00:00:00 LRE-10 0.000 0.000 0
This is an example of output from the show controllers lre status psd command:
Switch# show controllers lre status psd
------- Switch ------------ ----------- CPE -----------
Port Link SNR RSErr TxPwr AGCgain SNR RSErr TxPwr AGCgain
------ ---- --- ---------- ------ ------- --- ---------- ------ -------
Lo0/1 UP 32 0 - 6.13 13.0 43 0 - 85.6 - 2.0
Lo0/2 UP 32 0 - 6.13 15.1 42 0 - 85.9 - 2.0
Lo0/3 UP 32 0 - 6.13 13.5 42 0 - 85.6 - 2.0
Lo0/4 DOWN 10 0 - 5.85 63.9 0 0 0.0 0.0
Lo0/5 DOWN 10 0 - 5.85 58.9 0 0 0.0 0.0
Lo0/6 UP 33 0 - 6.13 15.1 42 0 - 85.9 - 2.0
Lo0/7 DOWN 10 0 - 5.85 54.2 0 0 0.0 0.0
Lo0/8 UP 33 0 - 6.13 14.6 42 0 - 85.9 - 2.5
Lo0/9 DOWN 10 0 - 5.85 52.9 0 0 0.0 0.0
Lo0/10 DOWN 10 0 - 5.85 61.5 0 0 0.0 0.0
Lo0/11 UP 33 0 - 6.13 15.1 42 0 - 85.9 - 1.6
Lo0/12 UP 33 0 - 6.13 15.1 42 0 - 85.9 - 2.5
Lo0/13 UP 33 0 - 6.13 15.1 42 0 - 85.9 - 2.5
Lo0/14 DOWN 10 268305 - 5.85 57.5 0 0 0.0 0.0
Lo0/15 DOWN 10 0 - 5.85 50.7 0 0 0.0 0.0
Lo0/16 UP 35 38 - 5.85 15.1 41 1238 - 85.9 - 6.4
Lo0/17 DOWN 10 767128 - 5.85 61.8 0 0 0.0 0.0
Lo0/18 DOWN 10 0 - 5.85 54.2 0 0 0.0 0.0
Lo0/19 DOWN 10 0 - 5.85 51.5 0 0 0.0 0.0
Lo0/20 DOWN 10 0 - 5.85 54.7 0 0 0.0 0.0
Lo0/21 DOWN 10 0 - 5.85 67.8 0 0 0.0 0.0
Lo0/22 DOWN 10 0 - 5.85 50.7 0 0 0.0 0.0
Lo0/23 DOWN 10 0 - 5.85 66.5 0 0 0.0 0.0
Lo0/24 DOWN 10 0 - 5.85 53.6 0 0 0.0 0.0
This is an example of output from the show controllers lre status sequence command:
Switch# show controllers lre status sequence
Port Sequence Status Profile
----- ----------------------- -------------- ---------------
Lo0/1 LRE-SEQ-DOWNSTREAM Converged LRE-15
Lo0/3 LRE-SEQ-SYM Converged LRE-15
This is an example of output from the show controllers lre status interleave command:
Switch# show controllers lre status interleave longreachethernet0/2
Port Link Profile Line Rate Block Size Delay(mSec)
------ ---- ---------------- -------------- ----------- -------------
Lo0/2 UP LRE-6 6.250 6.250 16 16 20.316 20.316
This is an example of output using the details keyword to obtain further information about the sequence:
Switch# show controllers lre status sequence detail
Sequence:LRE-SEQ-DOWNSTREAM Status:Converged Attempts:1
Profile:LRE-15 Convergence Time: 00:01:54
Rate-Selection:Enabled Locking:Not-Configured
Downstream Margin:2 Upstream Margin:0
Sequence:N/A Status:N/A Attempts:0
Profile:N/A Convergence Time: 00:00:00
Rate-Selection:Disabled Locking:Not-Configured
Downstream Margin:0 Upstream Margin:0
This is an example of output from the show controllers lre status cpe command:
Switch# show controllers lre status cpe
Lo0/1 : CPE-TYPE:Cisco575-LRE
Port Status Speed Duplex Protected
---- ------------ ----- ------ ---------
1 notconnected NA NA false
Port Status Speed Duplex Protected
---- ------------ ----- ------ ---------
Lo0/3 : CPE-TYPE:CISCO585-LRE
Port Status Speed Duplex Protected
---- ------------ ----- ------ ---------
1 notconnected auto NA false
2 notconnected auto NA true
3 notconnected auto NA false
4 notconnected auto NA false
5 connected 100 half false
Related Commands
show controllers lre version
Use the show controllers lre version privileged EXEC command to display the version numbers of the various components (hardware, firmware, and patch software) that make up the Long-Reach Ethernet (LRE) switch interface.
show controllers lre version [interface-id] [ | {begin | exclude | include} expression]
This command is available only on Catalyst 2950 LRE switches.
Syntax Description
interface-id
|
(Optional) ID of the switch LRE port.
|
| begin
|
(Optional) Display begins with the line that matches the specified expression.
|
| exclude
|
(Optional) Display excludes lines that match the specified expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
Privileged EXEC
Command History
Release
|
Modification
|
12.1(11)YJ
|
This command was introduced.
|
Usage Guidelines
Use the show controllers lre version command without specifying a switch LRE port to display the version numbers of all switch LRE interfaces.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output that shows the version information for an LRE interface:
Switch# show controllers lre version longreachethernet0/2
Related Commands
Command
|
Description
|
show controllers lre cpe
|
Displays the model numbers of the LRE CPE devices connected to the LRE switch and shows whether or not the connected CPE devices meet the minimum requirements for management by the LRE switch.
|
show controllers utilization
Use the show controllers utilization user EXEC command to display bandwidth utilization on the switch or specific ports.
show controllers [interface-id] utilization [ | {begin | exclude | include} expression]
Syntax Description
interface-id
|
(Optional) ID of the switch interface.
|
| begin
|
(Optional) Display begins with the line that matches the specified expression.
|
| exclude
|
(Optional) Display excludes lines that match the specified expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
User EXEC
Command History
Release
|
Modification
|
12.1(22)EA1
|
This command was introduced.
|
Usage Guidelines
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show controllers utilization command.
Switch> show controllers utilization
Port Receive Utilization Transmit Utilization
Switch Receive Bandwidth Percentage Utilization : 0
Switch Transmit Bandwidth Percentage Utilization : 0
Switch Fabric Percentage Utilization : 0
This is an example of output from the show controllers utilization command on a specific port:
Switch> show controllers fastethernet0/1 utilization
Receive Bandwidth Percentage Utilization : 0
Transmit Bandwidth Percentage Utilization : 0
Table 2-15 show controllers utilization Field Descriptions
Field
|
Description
|
Receive Bandwidth Percentage Utilization
|
Displays the received bandwidth usage of the switch, which is the sum of the received traffic on all the ports divided by the switch receive capacity.
|
Transmit Bandwidth Percentage Utilization
|
Displays the transmitted bandwidth usage of the switch, which is the sum of the transmitted traffic on all the ports divided it by the switch transmit capacity.
|
Fabric Percentage Utilization
|
Displays the average of the transmitted and received bandwidth usage of the switch.
|
Related Commands
Command
|
Description
|
show controllers ethernet-controller
|
Displays the interface internal registers or displays the statistics read from Long-Reach Ethernet (LRE) and customer premises equipment (CPE) ports.
|
show dot1x
Use the show dot1x privileged EXEC command to display IEEE 802.1x statistics, administrative status, and operational status for the switch or for the specified interface.
show dot1x [all] | [interface interface-id] | [statistics [interface interface-id]] [ | {begin | exclude
| include} expression]
Syntax Description
all
|
(Optional) Display the IEEE 802.1x status for all interfaces.
|
interface interface-id
|
(Optional) Display the IEEE 802.1x status for the specified interface.
|
statistics [interface interface-id]
|
(Optional) Display IEEE 802.1x statistics for the switch or the specified interface.
|
| begin
|
(Optional) Display begins with the line that matches the expression.
|
| exclude
|
(Optional) Display excludes lines that match the expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
Privileged EXEC
Command History
Release
|
Modification
|
12.1(6)EA2
|
This command was introduced.
|
12.1(14)EA1
|
The all keyword was added.
|
Usage Guidelines
If you do not specify an interface, global parameters and a summary appear. If you specify an interface, details for that interface appear.
If you specify the statistics keyword without the interface interface-id option, statistics appear for all interfaces. If you specify the statistics keyword with the interface interface-id option, statistics appear for the specified interface.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
These are examples of output from the show dot1x and the show dot1x all privileged EXEC commands:
Supplicant Allowed In Guest Vlan = Disabled
Dot1x Protocol Version = 1
Dot1x Oper Controlled Directions = Both
Dot1x Admin Controlled Directions = Both
Dot1x Info for interface FastEthernet 0/3
----------------------------------------------------
Supplicant MAC 00d0.b71b.35de
AuthSM State = CONNECTING
PortStatus = UNAUTHORIZED
Re-authentication = Disabled
ReAuthPeriod = 3600 Seconds
ServerTimeout = 30 Seconds
Dot1x Info for interface FastEthernet 0/7
----------------------------------------------------
PortStatus = UNAUTHORIZED
Re-authentication = Disabled
ReAuthPeriod = 3600 Seconds
ServerTimeout = 30 Seconds
This is an example of output from the show dot1x all privileged EXEC command when a restricted VLAN is configured:
Dot1x Info for interface GigabitEthernet0/1
----------------------------------------------------
Supplicant MAC 0002.b3eb.0df6
AuthSM State = AUTHENTICATED(AUTH-FAIL-VLAN)
PortStatus = AUTHORIZED(AUTH-FAIL-VLAN)
Re-authentication = Disabled
ReAuthPeriod = 3600 Seconds
ServerTimeout = 30 Seconds
AuthFail-Max-Attempts = 3
This is an example of output from the show dot1x interface fastethernet0/3 privileged EXEC command:
Switch# show dot1x interface fastethernet0/3
Supplicant MAC 00d0.b71b.35de
AuthSM State = AUTHENTICATED (AUTH-FAIL-VLAN)
ReAuthPeriod = 4000 Seconds { (From Authentication Server) | (Locally Configured) }
ReAuthAction = { Terminate | Reauthenticate }
TimeToNextReauth = 1453 Seconds
HostMode = Single (AUTH-FAIL-VLAN)
Re-authentication = Disabled
ReAuthPeriod = 3600 Seconds
ServerTimeout = 30 Seconds
This is an example of output from the show dot1x statistics interface fastethernet0/3 command. Table 2-16 describes the fields in the display.
Switch# show dot1x statistics interface fastethernet0/3
PortStatistics Parameters for Dot1x
--------------------------------------------
TxReqId = 15 TxReq = 0 TxTotal = 15
RxStart = 4 RxLogoff = 0 RxRespId = 1 RxResp = 1
RxInvalid = 0 RxLenErr = 0 RxTotal= 6
RxVersion = 1 LastRxSrcMac 00d0.b71b.35de
Table 2-16 show dot1x statistics Field Descriptions
Field
|
Description
|
TxReqId
|
Number of Extensible Authentication Protocol (EAP)-request/identity frames that have been sent.
|
TxReq
|
Number of EAP-request frames (other than request/identity frames) that have been sent.
|
TxTotal
|
Number of Extensible Authentication Protocol over LAN (EAPOL) frames of any type that have been sent.
|
RxStart
|
Number of valid EAPOL-start frames that have been received.
|
RxLogoff
|
Number of EAPOL-logoff frames that have been received.
|
RxRespId
|
Number of EAP-response/identity frames that have been received.
|
RxResp
|
Number of valid EAP-response frames (other than response/identity frames) that have been received.
|
RxInvalid
|
Number of EAPOL frames that have been received and have an unrecognized frame type.
|
RxLenErr
|
Number of EAPOL frames that have been received in which the packet body length field is invalid.
|
RxTotal
|
Number of valid EAPOL frames of any type that have been received.
|
RxVersion
|
Received packets in the IEEE 802.1x Version 1 format.
|
LastRxSrcMac
|
Source MAC address carried in the most recently received EAPOL frame.
|
Related Commands
Command
|
Description
|
dot1x control-direction
|
Resets the configurable IEEE 802.1x parameters to their default values.
|
show env
Use the show env user EXEC command to display fan information for the switch.
show env {all | fan | power | rps} [ | {begin | exclude | include} expression]
Syntax Description
all
|
Display both fan and temperature environmental status.
|
fan
|
Display the switch fan status (only available in privileged EXEC mode).
|
power
|
Display the internal power supply status.
|
rps
|
Display the Redundant Power System (RPS) status.
|
| begin
|
(Optional) Display begins with the line that matches the specified expression.
|
| exclude
|
(Optional) Display excludes lines that match the specified expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
User EXEC
Command History
Release
|
Modification
|
12.0(5.2)WC(1)
|
This command was introduced.
|
12.1(12c)EA1
|
The fan and power keywords were added.
|
Usage Guidelines
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show env all command:
Internal POWER supply is FAULTY
This is an example of output from the show env fan command:
This is an example of output from the show env power command:
Internal POWER supply is FAULTY
This is an example of output from the show env rps command:
show errdisable recovery
Use the show errdisable recovery user EXEC command to display the error-disable recovery timer information.
show errdisable recovery [ | {begin | exclude | include} expression]
Syntax Description
| begin
|
(Optional) Display begins with the line that matches the expression.
|
| exclude
|
(Optional) Display excludes lines that match the expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
User EXEC
Command History
Release
|
Modification
|
12.1(6)EA2
|
This command was introduced.
|
Usage Guidelines
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show errdisable recovery command:
Switch> show errdisable recovery
ErrDisable Reason Timer Status
----------------- --------------
security-violatio Disabled
channel-misconfig Disabled
psecure-violation Disabled
Timer interval:300 seconds
Interfaces that will be enabled at the next timeout:
Interface Errdisable reason Time left(sec)
--------- ----------------- --------------
Note
Though visible in the output, the unicast-flood field is not supported.
Related Commands
Command
|
Description
|
errdisable recovery
|
Configures the recover mechanism variables.
|
show interfaces trunk
|
Displays interface status or a list of interfaces in error-disabled state.
|
show etherchannel
Use the show etherchannel user EXEC command to display EtherChannel information for a channel.
show etherchannel [channel-group-number] {detail | load-balance | port | port-channel |
summary} [ | {begin | exclude | include} expression]
Syntax Description
channel-group-number
|
(Optional) Number of the channel group. The range is 1 to 6.
|
detail
|
Display detailed EtherChannel information.
|
load-balance
|
Display the load-balance or frame-distribution scheme among ports in the port channel.
|
port
|
Display EtherChannel port information.
|
port-channel
|
Display port-channel information.
|
summary
|
Display a one-line summary per channel-group.
|
| begin
|
(Optional) Display begins with the line that matches the expression.
|
| exclude
|
(Optional) Display excludes lines that match the expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
User EXEC
Command History
Release
|
Modification
|
12.1(6)EA2
|
This command was introduced. It replaced the show port group command.
|
12.1(14)EA1
|
The brief keyword was removed.
|
Usage Guidelines
If you do not specify a channel-group, all channel groups appear.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show etherchannel 1 detail command:
Switch> show etherchannel 1 detail
Port-channels: 1 Max Port-channels = 1
Port state = Down Not-in-Bndl
Channel group = 1 Mode = Automatic-Sl Gcchange = 0
Port-channel = null GC = 0x00000000 Pseudo port-channel = Po1
Port index = 0 Load = 0x00
Flags: S - Device is sending Slow hello. C - Device is in Consistent state.
A - Device is in Auto mode. P - Device learns on physical port.
Timers: H - Hello timer is running. Q - Quit timer is running.
S - Switching timer is running. I - Interface timer is running.
Hello Partner PAgP Learning Group
Port Flags State Timers Interval Count Priority Method Ifindex
Fa0/3 dA U1/S1 1s 0 200 Any 0
Age of the port in the current state: 10d:23h:07m:37s
Port-channels in the group:
Age of the Port-channel = 03d:02h:22m:43s
Logical slot/port = 1/0 Number of ports = 0
GC = 0x00000000 HotStandBy port = null
Port state = Port-channel Ag-Not-Inuse
This is an example of output from the show etherchannel 1 summary command:
Switch> show etherchannel 1 summary
Flags: D - down P - in port-channel
I - stand-alone s - suspended
u - unsuitable for bundling
-----+------------+-----------------------------------------------------------
1 Po1(SU) Fa0/1(Pd) Fa0/2(P)
This is an example of output from the show etherchannel 1 port command:
Switch> show etherchannel 1 port
Port state = Down Not-in-Bndl
Channel group = 1 Mode = Automatic-Sl Gcchange = 0
Port-channel = null GC = 0x00000000 Pseudo port-channel = Po1
Port index = 0 Load = 0x00
Flags: S - Device is sending Slow hello. C - Device is in Consistent state.
A - Device is in Auto mode. P - Device learns on physical port.
Timers: H - Hello timer is running. Q - Quit timer is running.
S - Switching timer is running. I - Interface timer is running.
Hello Partner PAgP Learning Group
Port Flags State Timers Interval Count Priority Method Ifindex
Fa0/3 dA U1/S1 1s 0 200 Any 0
Age of the port in the current state: 10d:23h:13m:21s
Related Commands
show file
Use the show file privileged EXEC command to display a list of open file descriptors, file information, and file system information.
show file {descriptors | information {device:}filename | systems} [ | {begin | exclude |
include} expression]
Syntax Description
descriptors
|
Display a list of open file descriptors.
|
information
|
Display file information.
|
device:
|
Device containing the file. Valid devices include the switch flash memory.
|
filename
|
Name of file.
|
systems
|
Display file system information.
|
| begin
|
(Optional) Display begins with the line that matches the specified expression.
|
| exclude
|
(Optional) Display excludes lines that match the specified expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
Privileged EXEC
Command History
Release
|
Modification
|
12.0(5.2)WC(1)
|
This command was introduced.
|
12.1(6)EA2
|
The descriptors and information keywords were added.
|
Usage Guidelines
File descriptors are the internal representations of open files. You can use this command to see if another user has a file open.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show file descriptors command:
Switch# show file descriptors
FD Position Open PID Path
0 187392 0001 2 tftp://temp/hampton/c2950g.a
1 184320 030A 2 flash:c2950-i-m.a
Table 2-17 describes the fields in the show file descriptors command output.
Table 2-17 show file descriptors Field Descriptions
Field
|
Description
|
FD
|
File descriptor. The file descriptor is a small integer used to specify the file once it has been opened.
|
Position
|
Byte offset from the start of the file.
|
Open
|
Flags supplied when opening the file.
|
PID
|
Process ID of the process that opened the file.
|
Path
|
Location of the file.
|
This is an example of output from the show file information nvram:startup-config command:
Switch# show file information nvram:startup-config
Table 2-18 lists the possible file types for the previous example.
Table 2-18 Possible File Types
Field
|
Description
|
ascii text
|
Configuration file or other text file.
|
coff
|
Runable image in coff format.
|
ebcdic
|
Text generated on an IBM mainframe.
|
image (a.out)
|
Runnable image in a.out format.
|
image (elf)
|
Runnable image in elf format.
|
lzw compression
|
Lzw compressed file.
|
tar
|
Text archive file used by the CIP.
|
This is an example of output from the show file systems command:
Switch# show file systems
Size(b) Free(b) Type Flags Prefixes
* 7741440 433152 flash rw flash:
7741440 433152 unknown rw zflash:
32768 25316 nvram rw nvram:
For this example, Table 2-19 describes the fields in the show file systems command output. Table 2-20 lists the file system types. Table 2-21 lists the file system flags.
Table 2-19 show file systems Field Descriptions
Field
|
Description
|
Size(b)
|
Amount of memory in the file system, in bytes.
|
Free(b)
|
Amount of free memory in the file system, in bytes.
|
Type
|
Type of file system.
|
Flags
|
Permissions for file system.
|
Prefixes
|
Alias for file system.
|
Table 2-20 File System Types
Field
|
Description
|
disk
|
The file system is for a rotating medium.
|
flash
|
The file system is for a flash memory device.
|
network
|
The file system is a network file system, such as TFTP, rcp, or FTP.
|
nvram
|
The file system is for an NVRAM device.
|
opaque
|
The file system is a locally generated pseudo file system (for example, the system) or a download interface, such as brimux.
|
rom
|
The file system is for a ROM or EPROM device.
|
tty
|
The file system is for a collection of terminal devices.
|
unknown
|
The file system is of unknown type.
|
Table 2-21 File System Flags
Field
|
Description
|
ro
|
The file system is read-only.
|
wo
|
The file system is write-only
|
rw
|
The file system is read/write.
|
show flowcontrol
Use the show flowcontrol user EXEC command to display the flow control status and statistics.
show flowcontrol [interface interface-id | module module-number] [ | {begin | exclude | include}
expression]
Syntax Description
interface interface-id
|
(Optional) Display the flow control status and statistics for a specific interface.
|
module module-number
|
(Optional) Display the flow control status and statistics for all Gigabit Ethernet interfaces. The only valid module number value is 0.
|
| begin
|
(Optional) Display begins with the line that matches the expression.
|
| exclude
|
(Optional) Display excludes lines that match the expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
User EXEC
Command History
Release
|
Modification
|
12.1(14)EA1
|
This command was introduced.
|
Usage Guidelines
Use this command to display the flow control status and statistics on the switch or for a specific interface.
Use the show flowcontrol command to display information about all the switch interfaces. (Flowcontrol is supported only on Gigabit Ethernet interfaces.) The output from the show flowcontrol command is the same as the output from the show flowcontrol module module-number command.
Use the show flowcontrol interface interface-id command to display flow control configuration and status information about the interfaces on the switch.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show flowcontrol command:
Port Send FlowControl Receive FlowControl RxPause TxPause
--------- -------- -------- -------- -------- ------- -------
Gi0/1 Unsupp. Unsupp. off off 0 0
Gi0/2 desired off off off 0 0
This is an example of output from the show flowcontrol interface interface-id command:
Switch> show flowcontrol gigabitethernet0/2
Port Send FlowControl Receive FlowControl RxPause TxPause
--------- -------- -------- -------- -------- ------- -------
Gi0/2 desired off off off 0 0
Related Commands
Command
|
Description
|
flowcontrol
|
Sets the receive flow-control state for an interface.
|
show interfaces
Use the show interfaces privileged EXEC command to display the administrative and operational status of all interfaces or a specified interface.
show interfaces [interface-id | vlan vlan-id] | [accounting | capabilities [module module-number]
| cpe [port port-id] | description | etherchannel | flowcontrol | media [interface-id] | pruning
| stats | status [err-disabled] | switchport | trunk | transceiver properties] [ | {begin | exclude
| include} expression]
Syntax Description
interface-id
|
(Optional) Valid interfaces include physical ports (including type, slot, and port number) and port channels. The port-channel range is 1 to 6.
|
vlan vlan-id
|
(Optional) VLAN ID. The range is 1 to
|
accounting
|
(Optional) Display accounting information on the interface, including active protocols and input and output packets and octets.
Note The display shows only packets processed in software; hardware-switched packets do not appear.
|
capabilities [module module-number]
|
(Optional) Display the capabilities of the specified interface or all interfaces on the switch. The module number is always 0. If you enter an interface ID, the module keyword is not visible.
|
cpe [port port-id]
|
(Optional) Display link status, speed, and duplex of all the customer premises equipment (CPE) Ethernet ports. You must enter an interface ID to display this keyword.
port port-id—Display only the designated CPE Ethernet port. The range is 1 to 4.
These keywords are available only on Long-Reach Ethernet (LRE) switches.
|
description
|
(Optional) Display the administrative status and description set for an interface.
|
etherchannel
|
(Optional) Display interface EtherChannel information.
|
flowcontrol
|
(Optional) Display interface flowcontrol information.
|
media [interface-id]
|
(Optional) Display the type of media connection. This keyword is available only on LRE switches.
|
pruning
|
(Optional) Display interface trunk VTP pruning information.
|
stats
|
(Optional) Display input and output packets by switching path for the interface.
|
status [err-disabled]
|
(Optional) Display the status of the interface, or display interfaces in error-disabled state.
|
switchport
|
(Optional) Display the administrative and operational status of a switching port.
|
trunk
|
Display interface trunk information. If you do not specify an interface, information for only active trunking ports appears.
|
transceiver properties
|
(Optional) Display speed and duplex settings for an interface.
|
| begin
|
(Optional) Display begins with the line that matches the expression.
|
| exclude
|
(Optional) Display excludes lines that match the expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|

Note
Though visible in the command-line help strings, the crb, fair-queue, irb, mac-accounting, precedence, random-detect, rate-limit, and shape options are not supported.
Command Modes
Privileged EXEC
Command History
Release
|
Modification
|
12.0(5.2)WC(1)
|
This command was introduced.
|
12.1(11)YJ
|
The cpe, port port-id, and media keywords were added.
|
12.1(12c)EA1
|
The capabilities keyword was added.
|
12.1(22)EA1
|
The transceiver and properties keywords were added.
|
Usage Guidelines
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show interfaces accounting command:
Switch# show interfaces accounting
Protocol Pkts In Chars In Pkts Out Chars Out
IP 17950 2351279 3205 411175
Interface Vlan5 is disabled
Protocol Pkts In Chars In Pkts Out Chars Out
Spanning Tree 2956958 179218508 34383 2131700
CDP 14301 5777240 14307 5722418
This is an example of output from the show interfaces capabilities command:
Switch# show interfaces fastethernet0/1 capabilities
Trunk encap. type: 802.1Q
Trunk mode: on,off,desirable,nonegotiate
Broadcast suppression: percentage(0-100)
Flowcontrol: rx-(none),tx-(none)
This is an example of output from the show interfaces command for a specified interface:
Switch# show interfaces fastethernet0/1
FastEthernet0/1 is up, line protocol is down
Hardware is Fast Ethernet, address is 0005.7428.09c1 (bia 0005.7428.09c1)
MTU 1500 bytes, BW 10000 Kbit, DLY 1000 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set
input flow-control is off, output flow-control is off
Last input never, output 4d21h, output hang never
Last clearing of "show interface" counters never
Input queue:0/75/0/0 (size/max/drops/flushes); Total output drops:0
Output queue :0/40 (size/max)
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
1 packets input, 64 bytes, 0 no buffer
Received 0 broadcasts, 0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
0 watchdog, 0 multicast, 0 pause input
0 input packets with dribble condition detected
1 packets output, 64 bytes, 0 underruns
0 output errors, 0 collisions, 2 interface resets
0 babbles, 0 late collision, 0 deferred
0 lost carrier, 0 no carrier, 0 PAUSE output
0 output buffer failures, 0 output buffers swapped out
This is an example of output from the show interfaces description command for an interface when the interface has been described as Connects to Marketing by using the description interface configuration command.
Switch# show interfaces gigabitethernet0/1 description
Interface Status Protocol Description
Gi0/1 up down Connects to Marketing
This is an example of output from the show interfaces pruning command for an interface when pruning is enabled in the VTP domain:
Switch# show interfaces fastethernet0/1 pruning
Port Vlans pruned for lack of request by neighbor
Port Vlan traffic requested of neighbor
This is an example of output from the show interfaces stats command:
Switch# show interfaces stats
Switching path Pkts In Chars In Pkts Out Chars Out
Processor 3224706 223689126 3277307 280637322
Total 3224706 223689126 3277307 280637322
Interface Vlan5 is disabled
Switching path Pkts In Chars In Pkts Out Chars Out
Processor 3286423 231672787 179501 17431060
Total 3286423 231672787 179501 17431060
This is an example of output from the show interfaces status command. It displays the status of all interfaces.
Switch# show interfaces status
Port Name Status Vlan Duplex Speed Type
Fa0/1 notconnect 1 auto auto 10/100BaseTX
Fa0/2 notconnect 1 auto auto 10/100BaseTX
Fa0/3 disabled 100 auto auto 10/100BaseTX
Fa0/4 connected trunk a-full a-100 10/100BaseTX
Fa0/5 notconnect 1 auto auto 10/100BaseTX
Fa0/6 connected trunk a-full a-100 10/100BaseTX
This is an example of output from the show interfaces status err-disabled command. It displays the status of interfaces in error-disabled state.
switch# show interfaces fastethernet0/1 status err-disabled
Fa0/1 err-disabled psecure-violation
This is an example of output from the show interfaces etherchannel command when port channels are configured on the switch:
Switch# show interfaces etherchannel
Port state = Up Mstr In-Bndl
Channel group = 1 Mode = On/FEC Gcchange = 0
Port-channel = Po1 GC = 0x00010001 Pseudo port-channel = Po1
Port index = 0 Load = 0x00
Age of the port in the current state:00d:00h:06m:54s
Age of the Port-channel = 09d:22h:45m:14s
Logical slot/port = 1/0 Number of ports = 1
GC = 0x00010001 HotStandBy port = null
Port state = Port-channel Ag-Inuse
Ports in the Port-channel:
------+------+------+------------
Time since last port bundled: 00d:00h:06m:54s Fa0/1
This is an example of output from the show interfaces flowcontrol command. Table 2-22 lists the fields in this display.
Switch# show interfaces flowcontrol
Port Send FlowControl Receive FlowControl RxPause TxPause
----- -------- -------- -------- -------- ------- -------
Fa0/1 Unsupp. Unsupp. off off 0 0
Fa0/2 Unsupp. Unsupp. off off 0 0
Gi0/1 desired off off off 0 0
Table 2-22 show interfaces flowcontrol Field Descriptions
Field
|
Description
|
Port
|
Displays the port name.
|
Send FlowControl
|
Admin
|
Displays the administrative (configured) setting for the flow control send mode.
|
Oper
|
Displays the operational (running) setting for the flow control send mode.
|
Receive FlowControl
|
Admin
|
Displays the administrative (configured) setting for the flow control receive mode.
|
Oper
|
Displays the operational (running) setting for the flow control receive mode.
|
RxPause
|
Displays the number of pause frames received.
|
TxPause
|
Displays the number of pause frames sent.
|
On
|
Flow control is enabled.
|
Off
|
Flow control is disabled.
|
Desired
|
Flow control is enabled if the other end supports it.
|
Unsupp.
|
Flow control is not supported.
|
This is an example of output from the show interfaces switchport command for a single interface. Table 2-23 describes the fields in the output.
Switch# show interfaces gigabitethernet0/1 switchport
Administrative Mode:dynamic desirable
Operational Mode:static access
Administrative Trunking Encapsulation:negotiate
Negotiation of Trunking:On
Access Mode VLAN:1 (default)
Trunking Native Mode VLAN:1 (default)
Administrative private-vlan host-association:none
Administrative private-vlan mapping:none
Operational private-vlan:none
Trunking VLANs Enabled:ALL
Pruning VLANs Enabled:2-1001
Capture VLANs Allowed:ALL
Unknown unicast blocked:disabled
Unknown multicast blocked:disabled
Voice VLAN:none (Inactive)
Table 2-23 show interfaces switchport Field Descriptions
Field
|
Description
|
Name
|
Displays the port name.
|
Switchport
|
Displays the administrative and operational status of the port. In this output, the port is in switchport mode.
|
Administrative Mode
Operational Mode
|
Displays the administrative and operational mode.
|
Administrative Trunking Encapsulation
Negotiation of Trunking
|
Displays the administrative and operational encapsulation method, and whether trunking negotiation is enabled.
|
Access Mode VLAN
|
Displays the VLAN ID to which the port is configured.
|
Trunking Native Mode VLAN
Trunking VLANs Enabled
Trunking VLANs Active
|
Note Lists the VLAN ID of the trunk that is in native mode. Lists the allowed VLANs on the trunk. Lists the active VLANs on the trunk.
|
Pruning VLANs Enabled
|
Lists the VLANs that are pruning-eligible.
|
Administrative private-vlan host-association > Administrative private-vlan mapping Operational private-vlan
|
Displays the administrative and operational status of the private VLAN and displays the private-VLAN mapping.
Note Private VLANs are not supported on the switch.
|
Capture Mode
Captured VLANs Allowed
|
Displays the capture mode and the number of captured VLANs allowed.
Note Because the switch does not support the capture feature, the values for these fields do not change.
|
Protected
|
Displays whether or not protected port is enabled (True) or disabled (False) on the interface.
|
Voice VLAN
|
Displays the VLAN ID on which voice VLAN is enabled.
|
Appliance trust
|
Displays the class of service (CoS) setting of the data packets of the IP phone.
|
This is an example of output from the show interfaces trunk command:
Switch# show interfaces trunk
Port Mode Encapsulation Status Native vlan
Fa0/4 on 802.1q trunking 1
Fa0/6 on 802.1q trunking 1
Port Vlans allowed on trunk
Port Vlans allowed and active in management domain
Port Vlans in spanning tree forwarding state and not pruned
This is an example of output from the show interfaces trunk command for an interface. It displays trunking information for the interface.
Switch# show interfaces fastethernet0/1 trunk
Port Mode Encapsulation Status Native vlan
Fa0/1 desirable 802.1q trunking 1
Port Vlans allowed on trunk
Port Vlans allowed and active in management domain
Port Vlans in spanning tree forwarding state and not pruned
This is an example of output from the show interfaces transceiver properties command. If you do not specify an interface, the output of the command shows the status on all switch ports:
Switch# show interfaces transceiver properties
Administrative Speed: auto
Administrative Duplex: auto
Administrative Auto-MDIX: N/A
Operational Auto-MDIX: N/A
Administrative Speed: auto
Administrative Duplex: auto
Administrative Auto-MDIX: N/A
Operational Auto-MDIX: N/A
Administrative Speed: auto
Administrative Duplex: auto
Administrative Auto-MDIX: N/A
Operational Auto-MDIX: N/A
This is an example of output from the show interfaces module number transceiver properties command for a specific interface:
Switch# show interfaces fastethernet0/1 transceiver properties
Administrative Speed: auto
Administrative Duplex: auto
Administrative Auto-MDIX: N/A
Operational Auto-MDIX: N/A
This is an example of output from the show interfaces command for an LRE port:
Switch# show interfaces longreachethernet0/5
LongReachEthernet0/5 is up, line protocol is up
Hardware is Ethernet over LRE, address is 0006.2871.5902 (bia 0006.2871.5902)
MTU 1500 bytes, BW 10000 Kbit, DLY 1000 usec,
reliability 255/255, txload 1/255, rxload 1/255
Encapsulation ARPA, loopback not set
Half-duplex, Auto Speed (10), 100BaseTX/FX
ARP type: ARPA, ARP Timeout 04:00:00
Last input 00:00:21, output 00:00:00, output hang never
Last clearing of "show interface" counters never
Output queue 0/40, 0 drops; input queue 0/75, 0 drops
5 minute input rate 0 bits/sec, 0 packets/sec
5 minute output rate 0 bits/sec, 0 packets/sec
8272 packets input, 852898 bytes, 0 no buffer
Received 1182 broadcasts, 0 runts, 0 giants, 0 throttles
0 input errors, 0 CRC, 0 frame, 0 overrun, 0 ignored
0 watchdog, 1182 multicast
0 input packets with dribble condition detected
61899 packets output, 17981033 bytes, 0 underruns
0 output errors, 0 collisions, 1 interface resets
0 babbles, 0 late collision, 0 deferred
0 lost carrier, 0 no carrier
0 output buffer failures, 0 output buffers swapped out
This is an example of output from the show interfaces command for all interfaces on a CPE device:
Switch# show interfaces longreachethernet0/2 cpe
---- ------------ ----- ------
This is an example of output from the show interfaces command for a port on a CPE device:
Switch# show interfaces longreachethernet0/2 cpe port 5
---- ------------ ----- ------
This is an example of output from the show interfaces media command on an interface:
Switch# show interfaces gigabitethernet0/1 media
Port Media-configured Active Attached
Gi0/1 auto-select rj45 1000BaseSX-10/100/1000BaseTX
This is an example of output from the show interfaces media command:
Switch# show interfaces media
Port Media-configured Active Attached
Gi0/1 auto-select rj45 1000BaseSX-10/100/1000BaseTX
Gi0/2 prefer-sfp sfp 1000BaseSX-10/100/1000BaseTX
Related Commands
Command
|
Description
|
switchport access
|
Configures a port as a static-access or dynamic-access port.
|
switchport protected
|
Isolates Layer 2 unicast, multicast, and broadcast traffic from other protected ports on the same switch.
|
switchport trunk pruning
|
Configures the VLAN pruning-eligible list for ports in trunking mode.
|
show interfaces counters
Use the show interfaces counters privileged EXEC command to display various counters for a specific interface or for all interfaces.
show interfaces [interface-id | vlan vlan-id] counters [errors | etherchannel | trunk] [ | {begin |
exclude | include} expression]
Syntax Description
interface-id
|
(Optional) ID of the physical interface, including type and slot and port number.
|
vlan vlan-id
|
(Optional) VLAN number of the management VLAN. The range is 1 to 4094.
|
errors
|
(Optional) Display error counters.
|
etherchannel
|
(Optional) Display etherchannel counters, including octets, broadcast packets, multicast packets, and unicast packets received and sent.
|
trunk
|
(Optional) Display trunk counters.
|
| begin
|
(Optional) Display begins with the line that matches the expression.
|
| exclude
|
(Optional) Display excludes lines that match the expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
Privileged EXEC
Command History
Release
|
Modification
|
12.1(6)EA2
|
This command was introduced.
|
12.2(22)EA2
|
The broadcast, multicast, and unicast keywords were removed.
|
Usage Guidelines
If you do not enter any keywords, all counters for all interfaces are included.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show interfaces counters command. It displays all the counters for the switch. Table 2-24 describes the fields in the output.
Switch# show interfaces counters
Port InOctets InUcastPkts InMcastPkts InBcastPkts
Gi0/1 23324617 10376 185709 126020
Port OutOctets OutUcastPkts OutMcastPkts OutBcastPkts
Gi0/1 4990607 28079 21122 10
Table 2-24 show interfaces counters Field Descriptions
Field
|
Description
|
InOctets
|
Displays the number of bytes received on an interface.
|
InUcastPkts
|
Displays the number of unicast packets received on an interface.
|
InMcastPkts
|
Displays the number of multicast packets received on an interface.
|
InBcastPkts
|
Displays the number of broadcast packets received on the interface.
|
OutOctets
|
Displays the number of bytes sent on an interface.
|
OutUcastPkts
|
Displays the number of unicast packets sent on an interface.
|
OutMcastPkts
|
Displays the number of multicast packets sent on an interface.
|
OutBcastPkts
|
Displays the number of broadcast packets sent on an interface.
|
This is an example of output from the show interfaces counters errors command. It displays the interface error counters for all interfaces. Table 2-25 describes the fields in the output.
Switch# show interfaces counters errors
Port Align-Err FCS-Err Xmit-Err Rcv-Err UnderSize
Port Single-Col Multi-Col Late-Col Excess-Col Carri-Sen Runts Giants
Table 2-25 show interfaces counters errors Field Descriptions
Field
|
Description
|
Align-Err
|
Displays the total number of frames that are received on an interface and have alignment errors.
|
FCS-Err
|
Displays the total number of frames that are received on an interface, have a valid length (in bytes), but do not have the correct FCS1 values.
|
Xmit-Err
|
Displays the total number of frames that have errors during transmission.
|
Rcv-Err
|
Displays the total number of frames that are received on an interface and have errors.
|
Undersize
|
Displays the total number of frames received that are less than 64 bytes (including the FCS bits and excluding the frame header) and have either an FCS or an alignment error.
|
Single-col
|
Displays the total number of frames that are successfully sent on an interface after one collision occurs.
|
Multi-col
|
Displays the total number of frames that are successfully sent on an interface after more than one collision occurs.
|
Late-col
|
After a frame is sent, displays the number of times that a collision is detected on an interface after 512 bit times.
|
Excess-col
|
Display the number of frames that could not be sent on an interface because more than 16 collisions occurs.
|
Carri-Sen
|
Displays the number of occurrences in which the interface detects a false carrier when frames are not sent or received.
|
Runts
|
Displays the number of frames received on an interface that are smaller than 64 bytes and have an invalid FCS value.
|
Giants
|
Displays the number of frames that are larger than the maximum allowed frame size and have a valid FCS value.
|
This is an example of output from the show interfaces counters trunk command. It displays the trunk counters for all interfaces. Table 2-26 describes the fields in the output.
Switch# show interfaces counters trunk
Port TrunkFramesTx TrunkFramesRx WrongEncap
Table 2-26 show interfaces counters trunk Field Descriptions
Field
|
Description
|
TrunkFrameTx
|
Displays the number of frames sent on a trunk interface.
|
TrunkFrameRx
|
Displays the number of frames received on a trunk interface.
|
WrongEncap
|
Displays the number of frames that are received on an interface and have the incorrect encapsulation type.
|
Related Commands
show inventory
Use the show inventory user EXEC command to display product identification (PID) information for the hardware.
show inventory [entity-name | raw] [ | {begin | exclude | include} expression]
Syntax Description
entity-name
|
(Optional) Display the specified entity. For example, enter the interface (such as gigabitethernet1/0/1) into which a small form-factor pluggable (SFP) module is installed.
|
raw
|
(Optional) Display every entity in the device.
|
| begin
|
(Optional) Display begins with the line that matches the expression.
|
| exclude
|
(Optional) Display excludes lines that match the expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
User EXEC
Command History
Release
|
Modification
|
12.1(22)EA5
|
This command was introduced.
|
Usage Guidelines
The command is case sensitive. With no arguments, the show inventory command produces a compact dump of all identifiable entities that have a product identifier. The compact dump displays the entity location (slot identity), entity description, and the unique device identifier (UDI) (PID, VID, and SN) of that entity.
Note
If there is no PID, no output appears when you enter the show inventory command.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output are not displayed, but the lines that contain Output are displayed.
Examples
This is example output from the show inventory command:
NAME: "sw-2-9-calg", DESCR: "Cisco Catalyst c2950 switch with 24 10/100 BaseTX ports and 2
GBIC (Gigabit Interface Converter) slots"
PID: WS-C2950G-24-EI , VID: A0 , SN: FHK0603Y088
show ip access-lists
Use the show ip access-lists privileged EXEC command to display IP access control lists (ACLs) configured on the switch.
show ip access-lists [name | number] [ | {begin | exclude | include} expression]
Syntax Description
name
|
(Optional) ACL name.
|
number
|
(Optional) ACL number. The range is 1 to 199 and 1300 to 2699.
|
| begin
|
(Optional) Display begins with the line that matches the expression.
|
| exclude
|
(Optional) Display excludes lines that match the expression.
|
| include
|
(Optional) Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
Privileged EXEC
Command History
Release
|
Modification
|
12.1(6)EA2
|
This command was introduced.
|
Usage Guidelines
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show ip access-lists command:
Switch# show ip access-lists
Standard IP access list testingacl
Standard IP access list wizard_1-1-1-2
Extended IP access list 103
permit tcp any any eq www
Extended IP access list CMP-NAT-ACL
Dynamic Cluster-HSRP deny ip any any
Dynamic Cluster-NAT permit ip any any
permit ip host 10.245.155.128 any
permit ip host 10.245.137.0 any
permit ip host 10.146.106.192 any
permit ip host 10.216.25.128 any
permit ip host 10.228.215.0 any
permit ip host 10.221.111.64 any
permit ip host 10.123.222.192 any
permit ip host 10.169.110.128 any
permit ip host 10.186.122.64 any
This is an example of output from the show ip access-lists 103 command:
Switch# show ip access-lists 103
Extended IP access list 103
permit tcp any any eq www
Related Commands
show ip dhcp snooping
Use the show ip dhcp snooping user EXEC command to display the DHCP snooping configuration.
show ip dhcp snooping
Syntax Description
This command has no arguments or keywords.
Command Modes
User EXEC
Command History
Release
|
Modification
|
12.1(19)EA1
|
This command was introduced
|
Usage Guidelines
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This is an example of output from the show ip dhcp snooping command:
Switch> show ip dhcp snooping
Switch DHCP snooping is enabled
DHCP snooping is configured on following VLANs:
Insertion of option 82 is enabled
Interface Trusted Rate limit (pps)
------------------------ ------- ----------------
FastEthernet0/5 yes unlimited
FastEthernet0/7 yes unlimited
FastEthernet0/5 yes unlimited
FastEthernet0/7 yes unlimited
FastEthernet0/5 yes unlimited
FastEthernet0/7 yes unlimited
Related Commands
show ip dhcp snooping binding
Use the show ip dhcp snooping binding user EXEC command to display the DHCP snooping binding table and configuration information for all interfaces on a switch.
show ip dhcp snooping binding [ip-address] [mac-address] [dynamic] [interface interface-id]
[static] [vlan vlan-id] [ | {begin | exclude | include} expression]
Syntax Description
ip-address
|
(Optional) Specify the binding entry IP address.
|
mac-address
|
(Optional) Specify the binding entry MAC address.
|
dynamic
|
(Optional) Specify the dynamic binding entry.
|
interface interface-id
|
(Optional) Specify the binding input interface.
|
static
|
(Optional) Specify the static binding entry.
|
vlan vlan-id
|
(Optional) Specify the binding entry VLAN.
|
| begin
|
Display begins with the line that matches the expression.
|
| exclude
|
Display excludes lines that match the expression.
|
| include
|
Display includes lines that match the specified expression.
|
expression
|
Expression in the output to use as a reference point.
|
Command Modes
User EXEC
Command History
Release
|
Modification
|
12.1(19)EA1
|
This command was introduced
|
Usage Guidelines
The show ip dhcp snooping binding command output shows the dynamically configured bindings.
If DHCP snooping is enabled and an interface changes to the down state, the switch does not delete the manually configured bindings.
Expressions are case sensitive. For example, if you enter | exclude output, the lines that contain output do not appear, but the lines that contain Output appear.
Examples
This example shows how to display the DHCP snooping binding entries for a switch:
Switch> show ip dhcp snooping binding
MacAddress IpAddress Lease(sec) Type VLAN Interface
------------------ --------------- ---------- ------- ---- --------------------
00:30:94:C2:EF:35 41.0.0.51 286 dynamic 41 FastEthernet0/3
00:D0:B7:1B:35:DE 41.0.0.52 237 dynamic 41 FastEthernet0/3
00:00:00:00:00:01 40.0.0.46 286 dynamic 40 FastEthernet0/8
00:00:00:00:00:03 42.0.0.33 286 dynamic 42 FastEthernet0/8
00:00:00:00:00:02 41.0.0.53 286 dynamic 41 FastEthernet0/8
This example shows how to display the DHCP snooping binding entries for a specific IP address:
Switch> show ip dhcp snooping binding 41.0.0.51
MacAddress IpAddress Lease(sec) Type VLAN Interface
------------------ --------------- ---------- ------- ---- --------------------
00:30:94:C2:EF:35 41.0.0.51 285 dynamic 41 FastEthernet0/3
This example shows how to display the DHCP snooping binding entries for a specific MAC address:
Switch> show ip dhcp snooping binding 0030.94c2.ef35
MacAddress IpAddress Lease(sec) Type VLAN Interface
------------------ --------------- ---------- ------- ---- --------------------
00:30:94:C2:EF:35 41.0.0.51 279 dynamic 41 FastEthernet0/3
This example shows how to display the DHCP snooping dynamic binding entries on a switch:
Switch> show ip dhcp snooping binding dynamic
MacAddress IpAddress Lease(sec) Type VLAN Interface
------------------ --------------- ---------- ------- ---- --------------------
00:30:94:C2:EF:35 41.0.0.51 286 dynamic 41 FastEthernet0/3
00:D0:B7:1B:35:DE 41.0.0.52 296 dynamic 41 FastEthernet0/3
00:00:00:00:00:01 40.0.0.46 46 dynamic 40 FastEthernet0/8
00:00:00:00:00:03 42.0.0.33 46 dynamic 42 FastEthernet0/8
00:00:00:00:00:02 41.0.0.53 46 dynamic 41 FastEthernet0/8
This example shows how to display the DHCP snooping binding entries on an interface:
Switch> show ip dhcp snooping binding interface fastethernet0/3
MacAddress IpAddress Lease(sec) Type VLAN Interface
------------------ --------------- ---------- ------- ---- --------------------
00:30:94:C2:EF:35 41.0.0.51 290 dynamic 41 FastEthernet0/3
00:D0:B7:1B:35:DE 41.0.0.52 270 dynamic 41 FastEthernet0/3
This example shows how to display the DHCP snooping binding entries on VLAN 41:
Switch> show ip dhcp snooping binding vlan 41
MacAddress IpAddress Lease(sec) Type VLAN Interface
------------------ --------------- ---------- ------- ---- --------------------
00:30:94:C2:EF:35 41.0.0.51 274 dynamic 41 FastEthernet0/3
00:D0:B7:1B:35:DE 41.0.0.52 165 dynamic 41 FastEthernet0/3
00:00:00:00:00:02 41.0.0.53 65 dynamic 41 FastEthernet0/8
Table 2-27 describes the fields in the show ip dhcp snooping binding command output.
Table 2-27 show ip dhcp snooping binding Command Output
Field
|
Description
|
MAC Address
|
Client hardware MAC address
|
IP Address
|
Client IP address assigned from the DHCP server
|
Lease (seconds)
|
IP address lease time
|
Type
|
Binding type
|
VLAN
|
VLAN number of the client interface
|
Interface
|
Interface that connects to the DHCP client host
|
Related Commands