Table Of Contents
Technical Specifications
Technical Specifications
Table A-1 through Table A-3 list the technical specifications for the Catalyst 2940 switches.
Table A-1 Technical Specifications for Catalyst 2940 Switches
Environmental Ranges
|
| |
Operating temperature
|
32 to 113° F (0 to 45° C)
|
| |
Storage temperature
|
-13 to 158° F (-25 to 70° C)
|
| |
Operating humidity
|
10 to 85% (noncondensing)
|
| |
Operating altitude
|
Up to 10,000 ft (3000 m)
|
| |
Storage altitude
|
Up to 15,000 ft (4570 m)
|
Power Requirements
|
| |
AC input voltage
|
100 to 240 VAC, 50 to 60 Hz
|
| |
Power consumption
|
15 W (maximum)
50 Btus per hour
|
Physical Dimensions
|
| |
Weight
|
3 lb (1.36 kg)
|
| |
Dimensions (H x W x D)
|
1.55 x 10.6 x 6.42 in. (3.94 x 26.92 x 16.3 cm)
|
Table A-2 Fiber-Optic Port Specifications for Catalyst 2940-8TF-Switch
Fiber-Port Power Levels
|
100BASE-FX port
|
|
| |
Optical transmitter wavelength
|
1300 nm2
|
—
|
| |
Optical receiver sensitivity for 50/125-micron cabling
|
-33.5 to -11.8 dBm3
|
—
|
| |
Optical receiver sensitivity for 62.5/125-micron cabling
|
-33.5 to -11.8 dBm
|
—
|
| |
Optical transmitter power for 50/125-micron cabling
|
-23.5 to -14 dBm
|
—
|
| |
Optical transmitter power for 62.5/125-micron cabling
|
-20 to -14 dBm
|
—
|
Table A-3 Catalyst 2940 Switch Agency Approvals
Safety
|
EMC
|
UL/CSA 60950
|
FCC Part 15 Class A
|
IEC 60950/EN 60950
|
EN 55022: 1998 (CISPR22) Class A
|
AS/NZS 60950
|
EN 55024: 1998 (CISPR24)
|
CE
|
VCCI Class A
|
| |
AS/NZS 3548 Class A
|
| |
CE
|
| |
CNS 13438 Class A
|
| |
MIC
|
| |
CLEI code
|
| |
USA CFR47, FCC, Part 15, Class A
|
| |
ICES-003, Class A
|
| |
EN55022/CISPR22, Class A, 1998
|
Safety
|
EMC
|
| |
EN 55024: ITE Immunity Standard. (CE Mark), 1998
|
| |
EN61000-4-2/IEC1000-4-2: Immunity to ESD
|
| |
EN61000-4-3/IEC1000-4-3: Immunity to Radio Frequency Electromagnetic Fields
|
| |
EN61000-4-4/IEC1000-4-4: Immunity to Electrical Fast Transients
|
| |
EN61000-4-5/IEC1000-4-5: Immunity to Power Line Transients (Surges)
|
| |
EN61000-4-6/IEC1000-4-6: Immunity to Radio Frequency Induced Conducted Disturbances
|
| |
EN61000-4-11/IEC1000-4-11: Immunity to Voltage Dips, Voltage Variations, and Short Voltage Interruptions
|
| |
AS/NZS 3548, Class A
|
| |
BSMI, Class A
|
| |
VCCI, Class A
|
| |
MIC Mark
|