The features supported by the
Cisco Nexus 5000 Series switch have maximum
configuration limits. Some of these limits apply only when one or more
Cisco Nexus 2000 Series Fabric
Extender units are attached to
the switch.
The following tables list the Cisco
verified limits for Cisco Nexus 5000 Series switches running
Cisco NX-OS Release
4.1.x.
Table 1 Ethernet Environments| Parameter
|
Limit
|
Active VLANs/VSANs per switch
|
512. 31 are set aside for VSANs and the remaining are for VLANs.
|
VLAN/VSAN ID Space
|
4,096
|
STP Logical Interfaces
|
3,6001
|
MST Instances per bridge topology per switch
|
64 (IEEE Standard)
|
VLAN ACLs (VACLs) per switch
|
1,024
|
Port ACLs (PACLs) per switch
|
2562
|
ACL Accounting
|
32
|
Member interfaces per EtherChannel
|
16
|
1 The 3600 logical interfaces apply to both PVRST and MST. If MST is used, the scale applies to the maximum number of MST instances (64).
2 There can be a maximum of 50 ACEs per PACL.
Table 2 Fibre Channel Environments| Parameter
|
Limit
|
Device Aliases per fabric
|
8,000
|
Switches per physical fabric or VSAN
|
503
|
Domains per VSAN
|
404
|
Native FC Links per switch
|
16—Requires two N5K-M1008 expansion modules.
|
FLOGIs or FDISCs per NPV port group
|
255
|
Zones per virtual or physical F port (includes all VSANs)
|
32
|
Zone sets per switch (includes all VSANs)
|
5005
|
Zone members per physical fabric (includes all VSANs)
|
8,0006
|
Zones per switch (includes all VSANs)
|
8,000
|
Maximum diameter of a SAN Fabric
|
3 hops7
|
FSPF interface instances per switch
|
5128
|
ISL instances per switch
|
2569
|
Virtual Fibre Channel interfaces
|
16010
|
|
Max FCIDs allocated
|
2,048
|
|
Fibre Channel Flows
|
32
|
3 The switch is capable of supporting up to 239 switches per fabric but this is not currently implemented.
4 The switch is capable of supporting up to 239 domains per VSAN but the scale is not currently implemented.
5 The switch is capable of 1000 Zone Sets but this is not currently implemented.
6 The switch is capable of supporting up to 20,000 zone members per fabric but the scale is not currently implemented.
7 The switch is capable of supporting up to 12 hops but the scale is not currently implemented.
8 The switch is capable of supporting 4096 (the number of Extended ISLs (16) times the
number of VSANs (256)) but the scale is not currently implemented.
9 Each ISL instance can support up to 32 VSAN
instances.
10 The switch is capable of supporting 480 virtual Fibre Channel interfaces
but the scale is not currently implemented.
Table 3 General Parameters| Parameter
|
Limit
|
|
Maximum Fabric Extenders per Cisco Nexus 5000 Series switch
|
12 units11
|
|
Maximum Fabric Extenders dual-homed to a vPC Cisco Nexus 5000 Series switch pair
|
12 units12
|
| Maximum number of hosts connected to Fabric Extenders connected to Cisco Nexus 5000 Series switches
|
480 hosts13
|
|
MAC Table Size
|
16,000 entries14
|
|
Event Traps - forward via Email
|
4 destinations15
|
|
QoS System Classes
|
5 all user-configurable classes
|
|
Port channels
|
4 SAN port channels and 16 EtherChannels (with the combination
not exceeding 16)
|
|
SPAN Sessions
|
2 active sessions
|
|
Egress SPAN sources
|
2
|
11 The number of
Fabric Extenders is limited by the total number hosts connected through the single homed
Fabric Extenders to the parent
Cisco Nexus 5000 Series switch. This applies both in the case where the parent switch is running vPC or not.
12 The number of
Fabric Extenders is limited by the total number hosts connected through dual homed
Fabric Extenders to a pair of
Cisco Nexus 5000 Series switches running vPC. In dual homed
Fabric Extender vPC mode, the
Fabric Extenders provide a redundant network path to the hosts in case of a direct failure in the primary path.
13 The limit of 480 applies equally to single homed and dual homed
Fabric Extender topologies. In single homed topologies, the maximum number of
Fabric Extenders is 12 which implies up to 40 hosts may be connected to each
Fabric Extender for a total of 480 hosts per
Cisco Nexus 5000 Series switch. In a dual homed
Fabric Extender topology, the total number of hosts supported is also 480.
14 1,000 entries are reserved multicast MAC addresses and the remainder are for unicast
MAC addresses.
15 The switch is capable of up to 50 different destinations but this is not currently implemented.