Bootup diagnostics detect faulty hardware before
bringing the switch online. Bootup diagnostics also check the data path and
control path connectivity between the supervisor and the ASICs. The following
table describes the diagnostics that are run only during switch bootup or
reset.
Table 1 Bootup Diagnostics
Diagnostic
|
Description
|
PCIe
|
Tests PCI express (PCIe) access.
|
NVRAM
|
Verifies the integrity of the NVRAM.
|
In band port
|
Tests connectivity of the inband port to
the supervisor.
|
Management port
|
Tests the management port.
|
Memory
|
Verifies the integrity of the DRAM.
|
Bootup diagnostics also include a set of tests that
are common with health monitoring diagnostics.
Bootup diagnostics log any failures to the onboard
failure logging (OBFL) system. Failures also trigger an LED display to indicate
diagnostic test states (on, off, pass, or fail).
You can configure
Cisco Nexus 5000 Series
switches to either bypass the bootup diagnostics, or run the complete set of
bootup diagnostics.